Tender For Tit- Bit Civil Work Along With Repair And Maintenance, Paintaing Work Of Kalyani Division Office Under Kalyani Division In The District Of Nadia- 1 Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m in ground floor including roof 2 b) In first floor 3 in second floor 4 in third floor 5 Dismantling all types of masonry excepting cementconcrete plain or reinforced, stacking serviceablematerials at site and removing rubbish as directedwithin a lead of 75 m. In ground floor including roof 6 b) In first floor 7 in second floor 8 in third floor 9 Dismantling all types of plain cement concreteworks, stacking serviceable materials at site andremoving rubbish as directed within a lead of 75m.in ground floor including roofupto 150mm thick 10 b) In first floor 11 in second floor 12 in third floor 13 Dismantling R.C. floor, roof, beams etc. includingcutting rods and removing rubbish as directedwithin a lead of 75 m. including stacking of steelbars. 14 b) In first floor 15 in second floor 16 in third floor 17 Earth work in excavation of foundation trenches ordrains, in all sorts of soil (including mixed soil butexcluding laterite or sandstone) including removing,spreading or stacking the spoils within a lead of 75 m.as directed. The item includes necess-ary trimming thesides of trenches, levelling, dress-ing and ramming thebottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm 18 Earth work in filling in foundation trenches or plinthwith good earth, in layers not exceeding 150 mm.including watering and ramming etc. layer by layer complete. (Payment to be made on the basis ofmeasurement of finished quantity of work)(a) With earth obtained from excavation of foundation 19 Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. 20 Cutting holes and subsequent mending good damages. (a) Diameter upto 150 mm. (i) In brick work [Cement-4.0 Kg/Mtr] 21 Cutting chase upto 125 x 150 mm. and subsequentmending of damages.(a) in brick wall [Cement-3.6 Kg/Mtr] 22 Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineerin charge. 23 Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. 24 Cement concrete with graded stone ballast (40 mm size excludingshuttering)In ground floor(A) [Pakur Variety](a) 1:3:6 proportionr and foundation 25 Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any as per relevant IS codes. a) Pakur Variety in ground floor 26 b) In first floor 27 in second floor 28 in third floor 29 Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominalsize excluding shuttering and reinforcement,if any,as per relevant IS codes. Pakur variety in ground floor 30 b) In first floor 31 in second floor 32 in third floor 33 Extra rate for using water proofing and plasticising admixture @ 0.2% byweight of cement (or at manufacturers specified rate) for concrete of variousgrades. 34 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety in ground floor 35 b) In first floor 36 in second floor 37 in third floor 38 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.a) For works in foundation, basement and upto roof of ground floor / upto 4m.Tor steel/Mild Steel.JSW/JSPL/SHYAM/ SRMB/BMASL/ELECROSTEEL/SSL 39 Brick work with 1st class bricks in cement mortar (1:6) In foundation and plinth 40 In superstructure-ground floor 41 In first floor 42 in second floor 43 in third floor 44 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.a) In ground floor 45 b) In first floor 46 in second floor 47 in third floor 48 Supplying, fitting & fixing 1st quality Ceramic tiles in wallsand floors to match with the existing work & 4 nos. of keystones (10mm) fixed with araldite at the back of each tile &finishing the joints with white cement mixed with colouringoxide if required to match the colour of tiles includingroughening of concrete surface, if necessary or by syntheticadhesive & grout materials etc.(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thickcement slurry at back side of tiles using cement @ 2.91Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m Other than Coloured decorative including white 49 A) FloorWith Sand Cement Mortar (1:4) 20 mm thick & 2 mm thickcement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m& joint filling using white cement slurry @ 0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.mOther than Coloured decorative including white 50 Supplying and laying true to line and level vitrified tiles ofapproved brand (size not less than 600 mm X 600 mm X 10mm thick) in floor, skirting etc. set in 20 mm sand cementmortar (1:4) and 2 mm thick cement slurry back side of tilesusing cement @ 2.91Kg./sqM or using polymerised adhesive(6 mm thick layer applied directly over finished artificial stonefloor/Mosaic etc without any backing course) laid afterapplication slurry using 1.75 Kg of cement per sqM belowmortar only, joints grouted with admixture of white cementand colouring pigment to match with colour of tiles / epoxygrout materials of approved make as directed and removal ofwax coating of top surface of tiles with warm water andpolishing the tiles using soft and dry cloth upto mirror finishcomplete including the cost of materials, labour and all otherincidental charges complete true to themanufacturer sspecification and direction of Engineer-in-Charge. (Whitecement, synthetic adhesive and grout material to be suppliedby the contrr]e)I(I) With application slurry @1.75 kg/ Sq.m, 20 mm sandcement mortar (1:4) & 2 mm thick cement slurry at back sideof tiles, 0.2 kg/ Sq.m white cement for joint filling withpigment.(A) Light colour(Gr.floor) 51 Rendering the Surface of walls and ceiling with White Cement baseWATER PROOF wall putty of approved make & brand.(1.5 mm thick)(i) Ground floor 52 In 1sl floor 53 in second floor 54 in third floor 55 Labour for taking out door and window frame including shutter for repair orreplacement of different parts of the frame & refixing the same including mendinggood all damaes complete. (Concrete and brick work for mending damage will bepaid separately)a) Upto area 2.5 Sq.m 56 M.S. or W.I. ornamental grill of approved design joints continuously welded with M.S. W.I. flats and bars for windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.i) Grill weighing above 16 Kg./sqma) In ground floor 57 b) In first floor 58 in second floor 59 in third floor 60 Removing old scales, blisters etc. of interior surface of walls,ceiling by scraping etc. and preparing smooth and even surface with rendering or cement mortar (1:2) (as necessary), to make the surface suitable for receiving distemper. (Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge) 61 M.S. structural works in columns, beams etc. with simple rolledstructural members (e.g. joists, angle, channel sections conformingto IS: 226, IS: 808 & SP (6)- 1964 connected to one another withbracket, gussets, cleats as per design, direction of Engineer-in charge complete including cutting to requisite shape and length,fabrication with necessary bolting, metal arc welding conforming toIS: 816- 1969 & IS: 1995 using electrodes of approved make andbrand conforming to IS:814- 2004, haulage, hoisting and erectionall complete. The rate includes the cost of rolled steel section,consumables such as electrodes, gas and hire charge of all tools andplants and labour required for the work including all incidentalchages such as electricity charges, labour insurance charges etc.II) For Structural Works in Roof Trusses etc. using joists, channelsand angles of specified section weighing less than 22.5 kg/ m 62 Supplying, fitting and fixing windows and ventilators with or withoutintegrated grills conforming to IS 1038-1975 and manufacture from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket,handle plate etc, including hoisting in position,straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing fixed with neceessary clamps and nuts and bolts and erected complete.(ii) below 50mm.(a) Fixed type steel windows as per IS sizes with horizontal glazing bars. 63 (b) Openable steel windows as per IS sizes with side hung shuttersand horizotal glazing bars. [The extra rate admissible for theopenable portion only] 64 steel peg stay 300 mm long including fitting and fixing. 65 Two point nose steel handle including fitting and fixing. 66 Taking out M.S. or W.I. Grills from wooden frame including cuttinglugs from masonry wall and refitting the same and mending gooddamages after repairs. (Excluding the cost of necessary repair ofdamages) or doing any other necessary works 67 Easing, oiling and adjusting the steel shutters including scraping allmembers and fitting so as to make the shutters easily operable (noextra payment will be made for taking out and fixing glass, ifnecessary). 68 Renewing M.S. members of steel shutters by welding including takingout the old, mending good damages complete, including taking outand refixing the glass panes. 69 Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).(c) Sal : Local 70 Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings.In ground floor.(In case of35mm thick shutters with 19mm thick panel of size 30 to 45 cm.(b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak. 71 Door stopper.(Brass) 72 Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed. a) With continuous plate base (Hexagonal / Round rod), (i)75 mm grip x 10 mm dia rod. 73 Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI100mm. X 75mm. X 3.5 mmmark. 74 Anodised aluminium barrel / tower / socket bolt (full covered) of approvedmanufactured from extruded section conforming to I.S. 204/74 fitted and fixedwith cadmium plated screws:ix) 300mm long x 10mm dia. bolt. 75 Anodised aluminium Aldrop / Sliding bolts of approved quality manufacturedfrom extruded section conforming to I.S. specification (I.S. 2681/66) fitted andfixed complete.300mm x 16mm dia. Bolt 76 Supplying fitting and fixing in position approved P.V.C. door frame (Matt finish) made of extruded P.V.C. multichamber hollow section having dimensions 60mm x 50mm x 2mm (+/-0.2mm), horizontal section will be joined with vertical section by galvanised steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40mm x 20mm x 1.20 mm will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of P.V.C. expandable fastner/wooden gutties and galvanised steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage of all materials, taxes and all other incidental charges complete. 77 PVC Door Shutter-37 mm thickSupplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of suitable size and section with 2.0 mm (+/-0.2 mm) wall thickness, the section will have 2nos. built in beads, horizontal & vertical section shall be fixed to each other by self tapping screws and 2 nos. of solid plastic or M.S. tubular galvanised brackets of length 200mm x 80mm and other 100mm x 100mm both 1.20 mm in each corner of the shutter frame for placing hinges. Polymer based multicavity hollow section of 105 mm x37mm with 2.0 mm (+/- 0.2 mm) wall thickness will be fitted in the middle as lock rail reinforced by solid polymer bar of 200 mm long at both ends abd screws from both sides. The section frame will then be fitted in by PVC panels of size 100 mmx20 mm with wall thickness of 1.2 mm (+/- 0.2 mm) and 2 nos. of 6 mm dia and screws from both sides 6mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / door ring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of all materials, labour, and hire of tools and plants and and appliencies. Carriage of all materials taxes and all other incidentalcharges complete.The rate is exclusive of cost of hinges, hasp bolt, towerbolt,door ring etc.In ground floor 78 in first floor 79 in second floor 80 in third floor 81 Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid T 2430 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 6 mm thick High Pressure Steam Cured NonAsbestos Fibre Cement Standard Ceiling Board (Density > 1300 Kg/m3) of size 595 mm X 595 mm, conforming IS 14862 & Type B Category III of ISO 8336, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge.In ground floor.False Ceiling (with 6mm thick Fibre Cement Standard Ceiling Board and E-Grid T-2430). 82 Supplying profiles of required section made of Aluminium AlloyExtrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - InCharge. (Payment will be made on finished length of the work).(B) 15 Micron colour annodizing. k) Movable door shutter ., i) Door frame. (Top & sides) 83 ii) Shutter :Top rail 84 Bottom rail 85 Door Vertical 86 Lock rail 87 Glazing cleap 88 Labour charge for fabrication and installation of composite door,window, partitions made from annodized extruded alloy aluminium sections for the following units:- (B) Partly glazed partly panelled or fully glazed single leaf alunminiumswing door made of extruded and annodized alloy aluminium sections, fabrication including cutting to proper shape and size, drilling and aligning, fitted with heavy duty hydraulic action floor sping placed in the floor with mending damages,with top pin assembly of approve make and brand, fitted with in built locking arrangement, flush bolt, glazing clips and all other necessary fittings, fixtures, adhesives and joineries, cutting glass of approved make to requisite shape and size fitting with dry setneoprene or EPDM gasketing, cutting to requisite shape and size panel board (prelaminated particle block) fixing them with glazing clips as per drawing, specification and direction of Engineer in charge. 89 Supplying bubble free float glass of approved make and brandconforming to IS: 2835-1987. i) 4mm thick clear glass. 90 Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filledwith foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP) . (b) 4mm thick (0.50mm Al.+3.0mm LDPE +0.50mm Al. PVDF coating) 91 Supplying profiles of required section made of Aluminium AlloyExtrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - InCharge. (Payment will be made on finished length of the work).(B) 15 Micron colour annodizing. i)natural White., Fixed partitions.(ii) Coloured(Unsupported length of vertical member more than 1.5 mtr.or both ends of vertical member restrained but panels more than 0.9 Sq.m)Top , bottom & side member. 92 Intermediate member. 93 Glazing clip. 94 Supplying heavy duty hydraulic double action floor spring along with top pin/set of pivots conforming to IS: 6315 or any approved make as per direction of Engineer in charge. 95 Supplying heavy duty top pin/set of pivots of local make and approved by the Engineer-in-charge. (This item to be provided where floor spring not 96 Supplying concealed type heavy duty PVC headed aluminium tower bolt for double leaf doors as per approved make and brand as per direction of Engineer-in-Charge.250 long 97 Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge.(weatger gasket/woolpile) 98 Filling the gap in between aluminium frame & adjacent RCC / Brick/ Stone work by providing weather silicon sealant over 6mm dia backer rod of approved quality as per architectural drawings and direction of Engineer-in-Charge complete. Upto 5 mm depth and 5 mm width 99 Extra for each additional floor 100 Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt , specially reinforced with non-woven polyester core with polyester reinforcement @160 gms per sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer @ 0.40 lit/sqm of manufacturers specification on smooth,clean dry surface prepared wherever required.Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finished surface area.). Membrane Property: Softening Point > 150 deg C, Cold Flexibility < -6 deg C, Tensile Strength, N/cm : 600 (longitudinal), 450 (transverse), Tearing Strength, N: 300 (longitudinal), 200 (transverse) 101 Repairs to cracks in terraced roof by cutting V-grooves 75 mm. to 100 mm. deep and 150 mm. to 200 mm. wide and filling the same with beaten lime concrete (2:2:7) with lime putty / paste and finishing complete (2 lime putty / paste : 2 surki : 7 brick khoa ) 102 Labour for painting roof surface with Bitumen (using 135 kg (avg.) per % Sq.m.)including cleaning roof, heating bitumen as directed and spreading sand and complete including cost of sand @ 0.6 cu.m. per % Sq.m. and cost of carriage of Bitumen from deptt godown but excluding the cost of bitumen. (If heating is not reqd. then deduct Rs.3.45/- per Sq.m) 103 Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturers specification [Cement to be supplied by the Department] 104 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including, rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface including threading nosing and drip course where necessary.i) With 1:6 cement mortar.a) 20 mm thick plaster.In ground floor 105 In first floor 106 in second floor 107 in third floor 108 15 mm thick- In ground floor. 109 In first floor 110 in second floor 111 in third floor 112 ii) With 1:4 cement mortar.10 mm thick plaster. 113 In first floor 114 in second floor 115 in third floor 116 Neat cement punning about 1.5mm. thick in wall, dado, window sills, floor, drain etc. 117 Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc.(Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge) 118 Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) 119 Applying Exterior grade Acrylic Primer of approved quality and brand on plastered or concretesurface old or new surface to receive decorative textured (mat finish) or smooth finish acrylic exterior Immersion paint including scrapping and preparing the surface thoroughly, complete as per manufacturers specification and as per direction of E.I.C(i)One coat .In ground floor 120 Protective and decorative Acrylic exterior emulsion paint of approved quality, as per manufacturers specification and as per direction of EIC to be applied over acrylic primer as required.The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.b) NORMAL Acrylic Emulsion.In Ground floor (Two Coat) 121 Removing loose scales, blisters etc. from old painted surface and thoroughly smoothening the surface to make the same suitable for receiving fresh coat of paint. 122 Priming one coat on timber or plastered or surface with synthetic oil bound primer of approved quality including smooth ening surfaces by sand papering etc. (This item is applicable to new work or old work when the original surface has been exposed by removal of old paint.) 123 Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. (This item is applicable to new work or old work when the original surface has been exposed by removal of old paint.) 124 (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary.(a) On timber or plastered surface :With super gloss (hi-gloss) - (iv) Two coats (with any shade except white) 125 (b) On steel or other metal surface :With super gloss (hi-gloss) (iv) Two coats (with any shade except white)-With super gloss (hi-gloss) - 126 Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall)3 mm thick (weighing 7.4 kg/Sq.m) 127 Renewing worn out putty of glass panes :Panes not exceeding 0.2 Sq.m 128 Supply fitting approved type ventilator in position after cutting holes in walls setting in cement mortar, mending damages to wall and plaster and two costs of point of approved brand and shade.(b) R.C.C ventilator of 20 mm. thicki) Upto 0.10 Sqm. Area 129 Artificial stone in floor, dado, staircase etc with cement concrete(1:2:4) with stone chips, laid in panels as directed with toppingmade with ordinary or white cement In ground floor. (as necessary) and marble3 mm. thick topping (High polishing grinding on this item is notpermitted with ordinary cement).(ii) 25 mm th.(i) Ground floor 130 Taking out carefully G.C.I. or C.I. or asbestos sheets (including ridges etc.) from roof or wallafter unscrewing bolts, nuts, screws etc.andstacking the material at site as directed. 131 Galvanised corrugated iron sheet work (excluding the supporting frame work) fitted and fixed with 10 mm. dia J or L hook-bolts, limpet and bitumen washers and putty complete with 150 mm. end lap and one corrugation minimum side lap. (Payment to be made on area of finished work)(GCI sheet to be supplied by contractor)(i) In Roof:-b) With 0.60 mm thick sheet 132 Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor).(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. 133 (f) 25 mm to 30 mm shuttering without staging in foundation 134 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming toIS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concretestructures etc if necessary and mending good damages including joining with jointing materails (SpunYarn,Valamoi/Bitumen/M-Seal etc) complete.A) UPVC Pipes:(ii) 110 mm. Dia. 135 Plain Tee.110 mm. Dia. 136 Plain Y.110 mm. Dia. 137 Bend 87.5 degree.110 mm. Dia. 138 Shoe.110 mm. Dia. 139 Uprooting and removing plants from the surface of wallsparapet etc and making good damages. (Repairing ofdamages to be paid separately) 140 Wood work in upper rails of railing, hand rail of staircase, balcony etc. includig1st class best Indian teak.necessary bend, moulding fitted and fixed complete (for purpose of paymentsection will be measured in the square 141 Renewing throating,nosing or drip course moulding with 15 mm.thick cement plaster (1:4) complete. (Cement 0.7Kg/Mtr.)In ground floor. 142 Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in- Charge prior to execution will be necessary).(Payment to be made on area cleared) 143 Spot application for insecticides using Aqua basespray for pest (for bugs, cockroaches, silverfish,spider, termites, mosquitoes) to walls and ceiling etc.with chemical emulsion by admixing chloropyrofosemulsifiableconcentrates (1% concentration) withwater by weight including spraying the emulsified chemical @ 0.5 litres per sq.m. by a hand operated pressure pump on wall surfaces, ceiling, electrical fixture,electrical lines including drilling holes in places where source of termite is detected squirtingchemical solution into the holes and sealing the holes with cement grout. (Rate is per sq.m. of the floor areawhile actual work will be all walls ceiling, rack, partition and furniture). 144 Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union cross, elbow nipple, long screw reducting socket reducing tee, short piece etc. fitted withholder bats clamps, including cutting pipes, making threads, fitting fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground (payment will be made on the center line measurements of total pipe line including all specials. No separate payment will be made for accessories, specials)(a) For Exposed Work i) 15 mm dia medium quality 145 ii) 20 mm dia medium quality 146 ii) 25 mm dia medium quality 147 (B) For Concealed Work15 mm dia. medium quality 148 20 mm dia. medium quality 149 25 mm dia. medium quality 150 Chromium plated round shower with revolving joint (Equivalent toCode No. 541(N) & Model - Tropical / Sumthing Special of ESSCO orsimilar brand). 151 Supplying, fitting and fixingpillar cock ofapproved make---CP pillar cock-15mm{Essco or similar band] 152 Supplying, fitting, fixing G.M wheel valve of approved brand and made tested to 21 Kg. Per sq. cm. (for water lines only.) --- i)20mm. 153 25mm 154 40mm 155 Supplying, fitting and fixing bib cock or stop cock.Chromium plated Bib Cock short body (Equivalent to Code No. 511& Model - Tropical / Sumthing Special of ESSCO or similar brand). 156 Chromium plated Stop cock [Equivalent to Code No.513(A) & 513(B) & Model - Tropical/Sumthing of ESSCO or similar brand] 157 Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver red as per I.S. 3438 / 1965 together with brass C.P. hinges.ii) 600 mm X 450 mm 158 Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc. b) With S trap (with vent) 159 Supplying, fitting and fixing towel rail with two brackets.a) C.P. over brass.b) I) 25 mm dia and 450 mm long 160 Supplying, fitting and fixing 18 mm. thick marble partition slab with chawk doongri marble square cut, both sides polished with two front corners rounded and edges polished. 161 Supplying, fitting and fixing white vitreous china best quality approvedmake wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks,C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillarcock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approvedquality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approvedquality P.V.C. connection pipe with heavy brass C.P. nut includingmending good all damages and painting the brackets with two coats ofapproved paint.(i) 450 mm X 300 mm size 162 Supplying, fitting and fixing Orissa pattern water closet in white glazedvitreous chinaware of approved make in position complete excluding P orS trap (excluding cost of concrete for fixing).(i) 580 mm X 440 mm each 163 Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. Specification withP.V.C fitting complete, C.I. brackets including two coats of painting to bracket etc. 164 Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make withnecessary fixing materials and clamps complete.i) Polythene Flush Pipe 165 Flat back urinal (half-stallin urinal)in white vitreous china ware of approved make (CERA/HINDWARE)supplied,fitted and fixed in position with brass screw on75mmx75mmx75mm wooden block complete. (i) 635 mm X 395 mm X 420 mm each 166 Supplying ,fitting and fixing approved brand p.v.c. connector white flexible ,with both ends coupling with heavy brass C.P.nut 15mm dia.1) 450mm. long. 167 Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe,with PVC coupling at one end fitted with necessary clamps.600 mm long 168 Supplying, fitting and fixing Half round channel with or without outlet asrequired set in cement concrete (6:3:1) with jhama chips complete.(Payment of concrete will be paid seperately). ii) 600 mm X 150 mmb) White vitreous chinaware 169 A) Extra for itemi) Channel with outlet, stop end 170 Approved patent vent cowl I.C.I. conforming to I.S.S.a) 75 mm dia. 171 Supplying PVC water storage tank approved quality with closed top with lid (block). Multilayer. a) 1500 Litre capacity. 172 Labour for dismantling G.I pipe with fittings.(i) 15 mm 173 (ii) 20 mm 174 (iii) 25 mm 175 Refixing G.I. pipe with fittings after cleaning where necessary.(i) 15 mm 176 (ii) 20 mm 177 25 mm 178 Removing chokage in G.I. pipe including cleaning pipe.(i) 15 mm 179 (ii) 20 mm 180 25 mm 181 Renewing C.I. clamp for pipe including cutting hole in wall etc. and mending good all damages with cement concrete(4:2:1) with jhama chips and cement plaster (6:1) to match with and curing.(i) 15 mm 182 (ii) 20 mm 183 Dismantling wash basin with brackets with or without waste fittings. 184 Dismantling E.P. or Anglo-Indian W.C. 185 Dismantling urinal. 186 Dismantling pillar cock of wash basin. 187 Cleaning glazed tiles with acid 188 Mazdoor