}

Tender For Provision Of Bpac And Double Distant Signal In Badnera Chandur Bazaar Section On Bhusawal Division, Ghaziabad-Uttar Pradesh

Central Electronics Limited has published Tender For Provision Of Bpac And Double Distant Signal In Badnera Chandur Bazaar Section On Bhusawal Division. Submission Date for this Tender is 15-10-2025. Railway Ancillaries Tenders in Ghaziabad Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

51422739
Tender For Provision Of Bpac And Double Distant Signal In Badnera Chandur Bazaar Section On Bhusawal Division
Tender
Indian
Uttar Pradesh
Ghaziabad
15-10-2025

Tender Details

Provision Of Bpac And Double Distant Signal In Badnera Chandur Bazaar Section On Bhusawal Division , Schedule (A) -Provision Of Bpac & Double Distant Signal In Bd-Cndb Section On Bhusawal Division. , Supplyofrelayrackassemblycompletewithscaffolding,Fixturesandaccessories Including Ms Bars For Fixing Of Relay Plug Board, String Rods, Fuse Strips With Bracket, 11 Way Bus Bars With Cover And Mounting Brackets, Runway For Cable/Wires, Frame, Base Assembly Etc. Siemens Type & As Per Extant Practice On C. Rly. Typical Part List And Rack Arrangement As Per Sketch No Sk-727 And Rack Plan As Approved By Engineer Incharge. (Inspection By Consignee) , Supply Of Tag Blocks 200 / 160/120 Way With Polycarbonate Cover As Per Irs S 77-2006 (Rev 1 ) Rdso Drg. No Sa 24751, Sa 24752 & Sa 24753 Requirement Of Each Type Shall Be Specified By Engineer Incharge .(Inspection By Rdso) , Supply Of Main Cable Termination Rackcomplete With Scaffolding, Fixtures & Accessories Including Square Bars For Mounting 8-Way Terminal Blocks, Ladder, String Rods, Frame, Base Assembly,Insulators,Jbolt,Nut/Bolts&Fasteners,Backelitesheet,Etc.Siemenstypeandasper Extant Practice On Central Railway. Typical Part List And Rack Arrangement Shall Be As Per Sketch No. Sk-727 With Latest Alterations. (Inspection By Consignee) , Supply Of Pvc Indoor Cable 1X60x0.6Mm Dia Colour Coding Of Insulation Of Inner Core Shall Be In Six Colour Viz Blue , Red , Grey ,Green, Brown And Black Conforming To Irs 76/89(Amdt 3) Or Latest. (Inspection By Rites) , Supply Of Pvc Indoor Cable 1X 40X0.6Mm Dia. Colour Coding Of Insulation Of Inner Core Shall Be In Eight Colour Viz Blue, Red, Grey, Green, Brown, Black, Yellow & White. Conforming To Irs 76/89 (Amdt 3) Or Latest. (Inspection By Rites) , Supplyofpvcindoorcable1x24x1mmdia.Colourcodingofinsulationofinner Conductor Shall Be In Eight Colour Viz Blue,Red,Grey,Green,Brown,Black, Yellow & White.Conforming To Irs 76/89 (Amdt 3) Or Latest. (Inspection By Rites) , Supplyofindoorjumperwire Ofvariouscolourasperrailwaysstandardpractice Of Type Atc 1 X 0.6 Mm Dia. Conforming To Irs 76/89 (Amdt 3) Or Latest.(Inspection By Consignee) , Supply Of Indoor Jumper Wire Atc 1 X 1 Mm Dia. Conforming To Irs 76/89 (Amdt 3) Or Latest. (Inspection By Consignee) , Supplyofpvcflexible Copper Cable,Singlecore,Multistrand1x2.5Sqmm(50 Conductoreachdia0.25+/-0.01)Asperspecnis694/2010Withlatestamendment.Ifanywith Insulation Thickness Of 0.70 Mm Nominal Conductor Resistance 7.98 Ohms /Km And Test Parameters Are As Per Irs (S)76/89 (Amdt .3). (Inspection By Consignee) , Supply Of Pvc Flexible Copper Cable,Singlecore,Multistrand1x10sqmm(80 Conductoreachdia0.40+/-0.01)Asperspecnis694/2010Withlatestamendment.Ifanywith Insulation Thickness Of 1.00 Mm Nominal Conductor Resistance 1.91 Ohms /Km And Test Parameters Are As Per Irs (S)76/89 (Amdt .3). (Inspection By Rites) , Supplyofwire16/0.2(Blue,Red,Gray,Yellow,Brown,Black,Whiteaspersiteengineer Instruction)Finolex/Polycab/Delton Make.Irs:S-76/89(Amd.3),Bs:4808 Part-2.Wire To Be Procured From Rdso Approved Vendor (Inspection By Consignee) , Supply Of Transformer 230V/110V-130V Single Phase 1 Kva As Per Spec. Irs S-72/88 (Amd.2) With Latest Amendments. (Inspection By Rdso) , Supplyoftransformersrectifierunit110vac/24Vdc500maasper Specn.No.Cr/S&T/91-12. (Inspection By Rdso) , Supplyofbatterychargerselfregulatingfloormountingtypewith230vacsingle Phase Input And Output 24V Dc, 30A As Per Spec. Irs.S.86/2000 (Amd.1) With Latest Amendments For Axle Counter Applications (Amd.4). (Inspection By Rdso) , Supplyofautomaticchangeoverforindividualsupplyautomaticchangeoverunitof Signal/Track/Dc Circuit Supply Of 32A, Ac/Dc Consisting Of 3Tc 44 Contactors, Led Lamp,Push Button, Terminals,Vsr,Polarity Switches. As Per Rly.Drg-Sk-841/1-5 For Ips Supply To Mannual Discrete Equipments With P/Switch. (Inspection By Rites) , Supply Of 63 A Rating, 4 Pole Changeover Switch Disconnector With Dual Shaft Position & Staggeredterminalswithsheetsteelenclosureandextendedhandleofsiemens/L&T/Havells/ Legrand Make. (Inspection By Consignee) , Supply Of Plug In Type Relay Metal To Metal Type Neutral Relay Mini Groups (Non Ac Immunised) Siemens Make (No. Rssk 30/0011) (Ref. Irs:S46/74 With Amd. 1 & Firms Specification.).Or Functionalequivalentwithoutbaseplates.Contactconfiguration5f/3Bor6f/2Bor4f/4Btobe Specified By Engineer Incharge. (Inspection By Rdso) , Supply Of Metal -To-Metal Universal Led Type Ecr Siemens Make (Type A-Rt-Rg-A064) Orfunctionalequivalentwithoutbaseplate,Shouldbesuitableforworkingwithledbasedsignal Lighting Unit. Irs:S:46 & Sts/E/Relays/Ac Lit Led Signal/09-2002 Amd. 1. (Inspection By Rdso) , Supply Of Qna1 Ac Immunized Relay 8F-8B,24Vdc Along With Plug Board, Retaining Clip And Connectors Conforming To Brs:931A, Irs:S60, Irs:S34 & Irs:S23. (Inspection By Rdso) , Supplyofuniversalledlampprovingrelayqecx61relay,4F-4B,Acconformingto Brs:941Asts/E/Relays/Aclitledsignal/09-2002,Amdt.-1(Forallaspectecrforacled Signal) (Inspection By Rdso) , Supply Of Qnna1- Ac Immunised Relay, 6F- 2B,24Vdc Along With Plug Board, Retaining Clip And Connectors Conforming To Brs:960, Irs:S60, Irs:S34 & Irs:S23. (Inspection By Rdso) , Supply Of Qna1k Relay 1000 Ohm,6F/6B 24V Dc As Per Brs :931A, Irs:S60, Irs:S34 & Irs:S23 And Rdso Spec. Sts/ E/ Relays/Uea (Pi) Dtd.30.05.1997 (Inspection By Rdso) , Supply Of Domino Units With Cover Plate As Per Approved Panel Diagram, Each Of Size 54 X 34Mm Completely Wired Up Similar To Siemens Make. Each Domino Units Should Have All The 15 Contact Terminals Wired Up.(Inspection By Consignee) , Supplyofpanelindicationbulbs(Doubleledtype)Workingvoltage24v-Colour- Red/Yellow/Green.(Inspection By Consignee) , Supplyofindicativetypeoffuseinserts.Irss:-78-92A)Withholder1.6A (System, Rapid Or Mainad Make). (Inspection By Consignee) , Supplyofindicativetypeoffuseinserts.Irss:-78-92B)Withholder0.6A (System, Rapid Or Malnad Make) (Inspection By Consignee) , Supply Of Indicative Type Of Fuse Inserts. Irs S:-78-92 C) Without Holder 1.6 A (System, Rapid Or Malnad Make). (Inspection By Consignee) , Supply Of Indicative Type Of Fuse Inserts. Irs S:-78-92 E) Without Holder 0.6 A (System, Rapid Or Malnad Make).(Inspection By Consignee) , Supplyofpptcfusegp250-185Ul-94Certifcaion(24V/4A)Tprcircuit) .Make:Littlefuse,Fuzetec,Tyco,Bourn,Raychem Etc(Inspection By Consignee) , Resin Cored Wire As Per Specification No. Is:1921-1975 With Alloying Element Percentage As 63% Sn (Tin) And / 37% Pb (Lead) With Percentage Of Various Impurities Not Exceeding Thevaluessb(Antimony)0.2%Maximum,Cu(Copper)0.1%Maximum,As(Arsenic)0.05% Maximum, Fe (Iron) 0.02% Maximum & Other Impurities Mainly Al, Zn & Cd Shall Be Limited. The Flux Shallbefreefromcorrosiveactionasperclause5.2&Fluxpercentagemaybeusedasper Requirement. (Inspection By Consignee) , Lacing Thread Rolls, Black, Wax Coated (100 Mtrs) (Inspection By Consignee) , Design,Fabrication And Supply Of Fuse Auto Changeover System For 32 Nos Of External Non Detorating Type Fuses Of G Type Fuses From 0.6 A Amp To 4A Amp Capacities Used In Signalling Circuits.System Shall Have 8 Cards With Monitoring Arrangement Of 4 Fuses In One Card.As Per Rdso Spec.Rdso/Spn/209/2012 Ver.2.0 Or Latest Amendment If Any. (No. Of Modules=Number) (Inspection By Rdso) , Design,Fabrication And Supply Of Fuse Auto Changeover System For 24 Nos Of External Nondetoratingtypefusesofgtypefusesfrom4ato10ampcapacitiesgenerallyusedforpoint Operation Circuits.Systemshallhave6cardswithmonitoring Of4fusesinonecard.Asperrdso Spec.Rdso/Spn/209/2012 Ver.2.0 Or Latest Amendment If Any. (No. Of Modules=Number) (Inspection By Rdso) , Supply Of Main Signal Post 140 Mm Outer Dia 5.6 Mtr Length As Per Spec No Irs S 6/81 With Latest Amendments.(Inspection By Rites) , Supply Of Cast Iron Main Signal Surface Base140 Mm As Per Spec No Irs S-10 And Drg No2011/Mwithlatestamendments,Withclsladderassemblycompleteforclssignal5.5/4.5/3.5 Mtrs Long As Per R. No Sa-23156(Adv),Sa 23153(Adv) & Sa 23150 (Adv) Alt. 1 Respectively With Latest Amendmentasthecasemaybe Forclsunit& Signalbackstagingasperextantc.Rlypractice. (Inspection By Rites) , Supply Of Signal No. Plates. As Per Drg No Rst-11393/Sk 842 (Inspection By Consignee) , Off Set Bracket 5-1/2 To Suit 140 Mm Dia Cls Post With Two Nos. Of U Bolts With Nutsandwashercompleteasperrdsodrgnosa-23080For Signals&Routes(Inspectionby Consignee) , Supply Of A/Ag/C/P/G/Ib Board As Per Drg Rst-11444/1(A), Rdso Drg No Sa 23460(Ag), Sa 23461( C) , Rst-11445 , Sa 23456(P), Sa 23477(G) & Sa 234476-77(Ib) As Applicable Respectively With Latest Amendment. (Inspection By Consignee) , Supply Of Stop Board/Ib Board As Per Rst-11791 (Stop Board)/ Rdso Drg No.7235/B As Per Extent C.Rly Practice. (Inspection By Consignee) , Supply Of Hand Cuff Locks/ Godrej Navtal Lock With Three Common Key (Inspection By Consignee) , Supplyof 3Aspectsignalunitinfrpbodywithoutlensesandtransformersasper Rdsospecificationrdso/Spn/194/2006/Rev2.0Orlatest Completetosuitledsignalslamps And Suitable For 140 Mm Dia Post Saves Pigment Finish On The Back Side Of The And Inside . White Pigment Finish Inside The 4 Aspect Unit To Avoid Any Extra Paint Cost. (Inspection By Rites) , Supply Of Fibre Glass Insulating Fire Retardent Sheet Of 10 Mm Thickness As Per Iso:10192-1982,Dielectric Strength -25Kv/Mm With Glass Content 25 To 34%, In Standard Size Of 1.10X1.10Mtr.As Per Spec.No.Is:10192-1982 (Inspection By Consignee) , Supply Of Ara Terminal Blocks With Links Made Of Pbt Specn No.Irs/75/2006(Rev - 2) With Latest Amendments And Rdso Drg.No.Sa-23741 Alt.4., Sa-23745 Alt 5, Sa-23746, Sa-23748 Alt - 4 & Sa-23756 Alt-3. (Inspection By Rdso) , Supply Of Cartridge Fuse Block Made Of Pbt As Per Rdso Drg No Sa-23748 Alt 4,Sa- 23749 & Spec No Irs S 75/2006 With Latest Amendment. Fuse Block Shall Be Suitable For Round Head Type Voltage Fuses.(Inspection By Rdso) , Supplyofroundheadtypenondetoriatingtypelowvoltagecartridgefuse Asper Specn No Irs/S/78/92 With Latest Amendments 2A/4A/6A Capacity(Inspection By Rdso) , Supplyoftik-Tak,Pianotypeswitches,5A(Asperisspecification).(Inspectionby Consignee) , Supplyofthreepoleplugandsocket5amp(Asperisspecification).(Inspectionby Consignee) , Supply Of Lamp 110V/24W,2 Pin For Loc. (Inspection By Consignee) , Supplyofapparatuscasewith Godownlockswithdeatachablehandleonboththe Doors. I) Single Case As Per Drg No Sk 783-1&2. With Latest Alteration. (Inspection By Rites) , Supplyofapparatuscasewith Godownlockswithdeatachablehandleonboththe Doors. Ii) Half Case As Per Drg No Sk 783-1&2. With Latest Alteration. (Inspection By Rites) , Supplyofearthelectrodeassemblyasperdrg.No.Cr/S&T/Sk/815(Inspectionby Consignee) , Maintenance Free Earth As Per Rdso/Spn/197/2008 Or Latest Consisting Of :1) Copper Bondsteelelectrode3mtrlong17mmdiawithcopperbondingthicknessofmin.250Micron&Ul Listed & Marked -01 No 2) Earth Enhancement Compound Rdso Approved In Sealed Bag Of 10Kgs-03 No 3) Copper Strip 150X25x6 Mm -02 No 4) Copper Strip 300X25x6 Mm -01 No 5)35 Sqmm Copper Cable To Connect Earth Electrod To Meeb-15 Mtr Approx. (Inspection By Rdso) , Ssdacinstallationfoundation & Erection Of Track Side Equipment I.E. Mushroom/ Location Box(Ifrequired).Thisincludessupplyofallassociatedmaterials.,-B)No.Individualearthingofall Detection Point For The Oem Recommended Earth Value Certified By Oem Site Engineer. This Includes Supply&Installationofmaintenancefreeearthmaterialsandexothermicbondingandother Connecting Cable Etc As Per Railway Practice (As Per Rdso Spec. No: Rdso/Spn/197/2008 Or Latest. Resetting Equipment To Be Connected To The Ei Ring Earth. C) Installation To Be Carried Out By Oem Certified Engineer. , Supply Of Electronic Timers For Dac Reset Arrangement 3 Sec To 30 Sec With 2 No/2Nc Contactworkingvoltage24v/60Vdcsiemens/Abb/L&Torselec(642Xaprogrammableelectronic Timer Switch)Make (Inspection By Rites) , Supply Of Gi Pipe, Inner Dia. 100Mm Dia. B-Class As Per Spec. No.Is 1239 Pt.1/2004 Or Latest With Sockets And Fittings.Tata/ Jindal/ Zenith Birla Make. (Inspection By Rites) , Supplyofdwchdpepipewithonesnapfitcouplerandoringfireresistant,Anti Rodent,In 6Mtr Length Of Size 120 Mm Outer Dia As Per Rdso /Spn /204/2011/Ver 1.1 With Amdt 1 Or Latest. (Inspection By Rites) , Supply Of Rcc Pipe Half Round Of Size 150Mm Dia Outer And 100 Mm Dia Internal 1 Mtr Long Matching To Is No.458/2003 Amendment-1 With Rev.4. (Inspection By Rites) , Supply Of C Channel Clamps With Nut Bolts, Washers And All Type Fixtures For 6 Inch Dia Pipe To Be Fixed On Girders, On Rock Cuttings Etc., As Per Drg No.Sk-900. (Inspection By Rites) , Supply Of Modular Terminal Block Of 2.5 Sqmm 2 In 2 Out Type Disconnect Type Terminal Alongwithas Per Rdso Specn.No.Rdso/Spn/189/2004 Rev 3.0. The Current Capacity Of 16 Amps & More,Theterminalshouldhavemarkingatcentretoviewdescriptionfromfront.Materialtobe Procured From Rdso Approved Firm Only. (Inspection By Rites) , Supply Of Din Channel For The Terminals 1 Mtr Each (Inspection By Consignee) , Supply Of End Plates For Modular Terminal Block (Inspection By Consignee) , Supply Of End Clamp For Modular Terminal Block (Inspection By Consignee) , Supply Of Marker Card As Per Customer Spec(10X10) (Inspection By Consignee) , Operating Tool (Operating Tool, Screw Driver & Stripper) As Per Annexure-Vii, (Inspection By Consignee) , Supplyofthermoshrinkjointingkit(Reinforced)Tsf-2Typegenerallyconformingto R D S O Specification No.Rdso/Spn/Tc/57/2015 Rev 1 With Modified Kit Contents As Per Cste Specificationno.Cr/Spn/Tc/57(A)/2015Dtd06.01.2015(Table-A)Tobesuitableforjointingboth 10/20/50 Pair Pijf And 4/6 Quad Cables Alongwith Sub-Kit(Table-B) For Armour Continuity.(Inspection By Consignee) , Schedule (B) - Provision Of Bpac & Double Distant Signal In Bd-Cndb Section On Bhusawal Division. , Installationofrelayrackassemblyincludingidfpillarsifanycompletewithwall Support,Scaffolding,Ladders,Runwayforcables,Relay/Relaygroupbaseplates,Fixingoftagblock Etc.The Work Shall Be Done As Per Approved Plan, Extant Practice On C. Railway & Instruction Of Rly. Engineer At Site. , Installationofcableterminationracksassemblycompleteincludingwallsupports, Scaffolding, Disconnecting Links/Ara Terminal, 96 Way Tag Block Cover & Other Necessary Accessories Etc. The Work Shall Be Done As Per Approved Plan, Extant Practice On C. Railways & The Instruction Of Rly Engineer At Site. , Fixing Of Q Series Relay Base Plate/Metal To Metal Relay Mini Group And Major Group Base Plate, Laying, Bunching, Lacing, Dressing & Packeting Of 60/40 Core Pvc Indoor Cable/Flexible Wire And Termination Of 60/40 Core Cable/Flexible Wire On Tagblock/Base Plate & Base Plates & Soldering. This Includes Fuse Wiring, Bus Bar Looping Etc. Required For Keeping Installation Ready For Circuit Wiring Work & Panel Throughing Work. The Work Shall Be Done As Per Approved Plan, Extant Practice On C.Rly. & The Instruction Of Rly. Engineer At Site. (Per Tag Block = Numbers) , Circuit Wiring/Jumpering As Per Circuit Diagrams In The Relay Racks/Idf Rack Tagblocks. This Includespreparation Of Jumper Sheets By Wire Man Duly Checked By Firms Site Supervisor & Wire Towiretestingaspercircuitdiagram.Anywrongjumperdonebywiremanwillnotbepaid& Correction Shall Be Done Free Of Cost.Jumper Wires Will Be Issued By Railways. Good Quality Solder Rosin Core To Be Supplied By Contractor For Soldering Of Jumper Wires. Soldering Of Jumper Wires (Jumper = Numbers) , Installation,Testingandcommissioningofautomaticmediachangeoverofmodems Working On Redundant Channels For Data Transmission On Ofc / Quad(Unit - One Pair Qty 1 Set) , Installation&Commissioningblockprovingwithdigitalaxlecounterasperrdso Specification No. Irs:S-105/2012 Using Ufsbi & Block Panel For Single / Double Line Operation. (Unit - One Pair Qty Is 1 Set) , Wiring, Fixing & Commissioning Of Modules Of Fuse 0.6 To 4 Amp Rating Alarm System Havingchangeoverarrangementandpotentialfreecontactwitingatdataloggeridfetcasper Instruction Of Railway Engineer (Module Of 32 Nos Fuses) No Of Modules= Numbers , Lettering & Numbering Of Detail And Description Writing Of Particulars Of Terminations &Equipmentsonrelayrack,Relays,Cableterminationrack,Battery&Powerequipments,Ips, Operating Panel, Axle Counter Etc Constituting Entire System With Contractors Own Paint And Writing Material(Asian/DuluxMakeenamelpaintstobeused).Theworkshallbedoneasperextant Practice On C.Rly & Instruction Of Rly Engineer At Site. , Preparationofcablerouteplan,Cablecoreageplan,Locationparticulars,Cable Terminationrackparticulars,Cablemeggeringreport,Earthresistanceparticulars,Tractionbonding Diagram,1/2Wirecountsheetandanyotherdrawinginautocadina3/A4size.Thecontractorshall Initially Supply 3 Sets Of Circuits Complete For Approval Of Railways. Railways Will Return One Set To The Contractor Duly Approved With Alterations/Corrections If Any. The Contractor Shall Incorporate Railways Alterations/Correctionsinthetracingswithoutanydeviationandsubmitalltracingscompleteinall Respectstotherailways.Thisincludessubmissionoffinalcablerouteplanasperlaidcableduly Measuredatevery30mclearlyindicatingdistanceoflaidcablefromfixedpointofreference& Indicating All Track Crossings And Tail Cables. This Also Include Designing Of Cable Covreage Plan Based Upon I.P In Consultation With Engineer-In-Charge. (For Small/Medium Yards) , Design And Supply Of Detailed Signalling Circuits Including Panel Diagram(If Required) , Route Section Plan , Selection Table , Fuse & Negative Tag. Analysis , Contact Analysis , Relay Rack Arrangement And Wire Count Sheets Etc. In A3 Size.Completion Circuit Shall Be Plotted In Autocad. The Contractor Shall Initially Supply 2 Sets Of Circuits Duly Signed By The Circuit Designer Having Substantial Experience On Design Side For Making Such Circuits, Complete For Approval Of Railways. Railways Will Returnonesetofcircuittothecontractordulyapprovedwithalterations/Corrections,Ifany.The Contractor Shall Incorporate Railways Alterations/Corrections In The Original Tracings & Cd Without Any Deviationandsubmittwocopiesofthemodifiedcircuits.Originaltracingssomodified&Finalcd Completeinallrespectsalongwith6setsoffinalapprovedcircuits(Outofwhichonesetshallbe Suppliedintransparentbags.Onlytwosheetsofcircuitsshallbeplacedinonebageach)Shallbe Submittedtotherailwaysincasetherearenofurtheralterationsuggestedbyrailways.Thisalso Includes Modification In Yard.(For Ibs/Abs/Lc Gate) , Preparation Of Final Ammonia Prints Of Diagrams In A-3 Size After Tracings Are Approved Byrailways,Infoursetsforfinalsubmissionwithonesetofdiagramintransparentpolythene Bag/Lamination (Only Two Sheets Shall Be Placed In One Polythene Bag/Laminated Each). Every Set Shall Be Set In A Plastic Folder Of A3 Size And Of Good Quality. The Final Approved Tracings Will Be Handed Over To Contractor By Railway For This Purpose And Contractor Will Return Back The Same After Taking Out The Prints For Stations Having Less Than 20 Routes.(F0r Ibs/Abs/Lc Gate) , Excavation And Casting Of Main Signal Foundation Asperdrgnosk801with Contractorsownmaterialsincludingcementandanchorboltsofstandardsize.Therequired Scaffolding Ferma Etc For Casting Of Foundation Will Have To Be Brought By The Contractor At His Own Cost. , Erection Of Cls Post With Surface Base And Signal Unit On Top Or On Off Set Bracket, Fixing Of Front And Back Staging, Ladder And Guards, Signal Name Plates/Boards If Any With Contractors Own Brackets And Fixing Materials. This Also Includes Erection Of Auxiliary Signals Like Calling On, Shunt Signal If Any. The Work Shall Be Done As Per Instructions Of Rly Engineer At Site. , Fixing Of Stop Board, Block Section Limit Board, Goods Warning Board With Contractors Own Material. The Work Shall Be Done As Per Instruction Of Rly Engineer At Site. , Termination Of Tail Cable On Main Signal Units And Wiring With Contractor Own Material, Etc. The Work Shall Be Done As Per Instruction Of Rly Engineer At Site. , Fabricationandfixingofphenoliclaminated/Fibreglasssheetinlocationboxby Providingallfixturesasperrailwaydrawingincludingfixingofpvccoated/Withpvcpipecovered String Rods At The Back Side For Cable Support With Contractors Own Materials. The Work Shall Be Done As Per Drg And Arrangement Similar To Sk 783-1/2. With Latest Alterations & As Per Instructions Of Rly Engineer At Site. A) Single Case. , Fabricationandfixingofphenoliclaminated/Fibreglasssheetinlocationboxby Providingallfixturesasperrailwaydrawingincludingfixingofpvccoated/Withpvcpipecovered String Rods At The Back Side For Cable Support With Contractors Own Materials. The Work Shall Be Done As Per Drg And Arrangement Similar To Sk 783-1/2. With Latest Alterations & As Per Instructions Of Rly Engineer At Site. B) Half Case , Fixingofaraterminalsandfuseblocksonphenoliclaminated Sheetsandfixingby Stainless Steel/Brass Nuts & Bolts.This Includes Provision Of Two Additional Holes On The Board On Either Side For Cable Conductor Entry. , Excavationandcastingofapparatuscasefoundationwithcontractorsanchorbolts, Cement, Ballast And Other Materials.The Required Scaffolding Ferma Etc For Casting Of Foundation Will Have To Be Brought By The Contractor At His Own Cost A) Single Case As Per Drg No Sk 803 , Excavationandcastingofapparatuscasefoundationwithcontractorsanchorbolts, Cement, Ballast And Other Materials.The Required Scaffolding Ferma Etc For Casting Of Foundation Will Have To Be Brought By The Contractor At His Own Cost B) Half Case As Per Drg No Sk 804 , Erection Of Apparatus Cases. This Includes Filling Of Location Foundations And Plastering.A) Single Case , Erection Of Apparatus Cases. This Includes Filling Of Location Foundations And Plastering. B) Half Case , Installation Of Eqpt. (Relays, Resistance, Chargers Batteries Etc.As Applicable) & Wiring Of The Same In Apparatus Cases As Per Location Diagrams & Circuit Diagrams, As Per Instruction Of Site Incharge And Practice. A) Single Case , Installation Of Eqpt. (Relays, Resistance, Chargers Batteries Etc.As Applicable) & Wiring Of The Same In Apparatus Cases As Per Location Diagrams & Circuit Diagrams, As Per Instruction Of Site Incharge And Practice. B) Half Case , Installationofearthelectrodeassenblyasperdrg.No.Re/S&T/Sig/Tender/Sk726/85 Including Earth Wire Connected Through Gi Wire 8 Swg Supported On M.S. Flat Of Size 6Mm X 40 Mm To Earthelectrodeasperdrg.No.Cr/S&T/Sk-815Forsigg.Equipmentsuchasleverframes,Apparatus Case, Signals, Relay Racks,Block Insruments, And Etc. As Per Re Manual. The Earth Value Should Be Less Than 10 Ohms Including The Lead Wire. The Value Should Be Measured In Presence Of Rly. Supervisor. It Should Be Documented And Painted On Earth Enclosure Made Of Concrete.( Only Earth Electrode Will Be Suppliedbyrailway).Allothermaterialrequiredforprovisionofearthingwillbebroughtbythe Contractor. , Installation Of Unit Earth As Per Rdso/Spn/197/Ver I Or Latest, To Construct Earthing Of </= 1 Ohm Consisting Of A. Digging The Earth To Required Depth, Insertion Of Electrode, Filling Of Earth Enhancing Compound & Construction Of Chamber, Measurement Of Earth Value And All Other Work Of Earthing As Per Code Of Practice. All The Consumables For Mounting The Copper Tape Inside The Relay Room, Exothermic Weld Materials And Tools & Fixtures For The Welding Copper Tapes And Electrodes Etc Shall Be Arranged By The Contractor. , Installationofaxlecounter(Digital)/Centralevaluator,Wiringfromctracktocentral Evaluator, Installation And Wiring Of Indoor & Outdoor Reset Box And Wiring The Power Supply Including Supply Of 2 Core Shielded Cable Of Required Size Copper Conductor As Per Irs S 76/89 Or Is 694/1977 As Applicablewithotheraccessories. Note:Installation/Programming/Configuration/Commissioningof Axle Counter Equipment To Be Carried Out In Accordance With Latest Guidelines Issued By Railways/Rdso Preferably By Authorised Representative Of Oem. , Installation Of Ejb And Track Devices Of Digital Axle Counter Including Digging Of Trench, Drilling Of Hoels,If Required On Rail , Laying Of Doubled Walled Antirodent Corrugated Pipe, Medium Class From Track Device To Location Box And Making Its Terminations. ( Dwc Pipe Made Up Of High Density Polyethylene Of 60Mm Outer Dia Of Suitable Length And All Other Accessories As Per Site Requirement To Besuplliedbyfirm.) Note:Installation/Programming/Configuration/Commissioningofaxlecounter Equipment To Be Carried Out In Accordance With Latest Guidelines Issued By Railways/Rdso Preferably By Authorized Representative Of Oem. , Installation Of Complete Assembly Of Deflectors On Either Side Of Track Device/Double Rail Contact Unit Including Drilling Of Required Sizes Holes On Rails For Fixing These. , Excavationofcabletrenchaspercablerouteplan,1.0Mt.Deepand300mmwide Along Side The Track In Normal Soil/Strata, Conforming To Distances As Per Cable Route Plan And Refilling After Cable Laying. This Work Includes Covering Of Cable Laid In Trench By Loose Soil For A Layer Of 50Mm Thicknessafterclearingofroute,Bushesetc.Itshallbeensuredthattopofthecableslaidisata Depthof0.8Mormoreifitisless,Thenthewidthanddepthshallbesuitablyincreasedand Accordingly Proportionate Payment Shall Be Made .In Case Depth Of Trench Is Not Achievable Due To Site Conditions, Proportionate Payment Will Be Made As Per Procedure. The Work Shall Be Done As Per The Extant Practice On Central Railway And Instructions Of Railway Engineer At Site. Drg No.Sk 805 , Excavationofcabletrenchaspercablerouteplan,1.0Mt.Deepand300mmwide Along Side The Track In Hard Soil, Conforming To Distances As Per Cable Route Plan And Refilling After Cablelaying.Thisworkincludescoveringofcablelaidintrenchbyloosesoilforalayerof50mm Thickness After Clearing Of Route,Bushes Etc.It Shall Be Ensured That Top Of The Cables Laid Is At A Depth Of0.8Mormoreifitisless,Thenthewidthanddepthshallbesuitablyincreasedandaccordingly Proportionatepaymentshallbemade.Incasedepthoftrenchisnotachievableduetosite Conditions,Proportionate Payment Will Be Made As Per Procedure.The Work Shall Be Done As Per The Extant Practice On Central Railway And Instructions Of Railway Engineer At Site.Drg No.Sk 805 , Cuttingofalltypesofroads/Platforms(Exceptconcretetype)Fortrenchingand Excavation To Depth Of 300Mmx300mm Wide Approx. And Refilling After Laying Of Rcc/Gi/Dwc Pipe & Torestorethemtooriginalcondition.Theworkshallbedoneasperextantpractice Onc.Rly& Instructions Of Rly Engineer At Site.Sk-807 , Fixingofgipipesforcrossingtheculverts,Bridgesetc.Andconcretingofendswith Brick Masonry At Both Ends As Per The Instruction Of Rly Engineer At Site. , Diggingoftrench1.0Mdeepfromrailflange/Roadlevel(Forlc)And0.3Mtrsto0.6 Mtrswideandbackfillingafterplacingofdwc/Rcc/Gipipe(Placingofdwc/Rcc/Gipipecovered Separately) The Ballast Disturbed Be Screened And Dressed As Required By Engineer In-Charge Or His Representatives And Road Tarred Immediately. Drg No.Sk 806 , Laying Of Dwc/Rcc Pipes Along With Collars/Rcc Half Round Pipe In Trenches At Places Of Track And Road Crossings, Platform Cuttings Etc. , Laying Of Signalling/Power/Telecom Cable Of Various Cores/Sizes In Trenches. , Placing And Securing Of Cable Route Markers In Trenches At The Specified Interval And At Diversions,Jointsetcalongthecableroute.Theworkshallbedoneasperextantpracticeonc Railways & The Instruction Of Rly Engineer At Site. , Jointing Of 4 / 6 Quad Cable With Heat Shrinkable Straight Through Jointing Kit For 4 / 6 Quad Cable. , Whereeverdepthof0.5Mcabletrenchisnotfeasiblecableshallbeprotectedas Under:- Preparation Of Cement Mixture 1:3:6 With Contractors Own Materials And Spreading Cement Concrete Mixture Layer Of 100 Mm Thick Over The Already Laid Cables In The Excavated Trench. , Fixingofmodularterminal/Fuseblocksalongwithallaccessorieswithprovisionof Fixingholesonhylamsheets/Sideanglesoflocboxandfixingbygalvanisednuts&Bolts.This Includes Fixing Of Din Channel Alongwith Pvc Comb Type C Channel (Size 2 Inch X 2 Inch) For Cable Termination On Modular Terminal. The Pvc Channel With Cover To Be Supplied By Firm As Required. The Work Shall Be Done As Per The Instruction , Terminationofcablecoresonaraterminal/Disconnectinglink/Fuseblocks,Inthe Apparatus Cases/ Cable Termination Rack. This Includes All Associated Works Of Pulling Out The Cable From Underground. The Work Shall Be Done As Per Location Plans And Instructions Of Rly Engineer At Site. , Layingofgipipesinonbridges/Culverts/Concretedrain/Mountainridgesetc.With Suitablegibendshallbeprovidedwherethereisturningofpipeasperinstructionsofthesite Engineer. Gi Clamps At Every 2 M As Shown In The Drawing To Be Fixed. Suitable Holes To Be Made In The Pipe Before Laying As Per Instructions Of The Site Engineer. 100 Mm Dia. Drg No Sk 808 , Fixing Of C Channel Clamps On Girders. Along With Proper Coupling Of Gi/Dwc Pipes. The Work Will Be Executed As Per Instruction Of Site Incharge And Site Incharge May Take Decisioin As Persitecondition.Allthefixtures,Nutbolts,Tollsrequiredtofixthechannelwillbeprovidedby Contractor. Proper Safety Equipment Like Helmet, Retereflective Jacket And Whistle, Flag Is To Be Made Available During Execution Of Work. , Horizontal Boring Of Cable Duct Of Minimum 2.0 Mtr Depth Along With Laying Of 120 Mm Hdpe Pipe For Track Crossing Wirh Minimum Depth Reckoned From Bottom Of The Rail/Road Crossing With Minimumdepthreckonedfromgroundlevel.Theworkshallbedoneasperextentpractice& Instruction Of Site Engineer. Preparation Of Site For Horizontal Boring Shall Be Carried Out In Presence Of Railway Representative. Hdpe Will Be Supplied By Railway. Note:- Contractor Shall Provide All Material Required For Boring And Adequate Nos.Of Labours For Proper Laying Of Cable Into The Bore. Cable Shall Be Laid Cautiously So That It Should Not Get Damage Due To Rough Handling & Pressure On Cable. , Transferringofsignalling/Telecomcablesfromexistinglocationboxtonewlocation Box.Theworkincludebreaking/Dismantlingofexistingfoundationoflocations,Excavatingand Removing /Segregating Coils Of This Cables Which May Be Of About 10 Mtr In Length .These Cables Are Then To Be Disconnected And Removed From The Existing Locations One By One As Per The Instructions Andunderthesupervisionofrailwaystaffpresentatsite.Thecableisthentobeinsertedand Terminated In New Location Box. The Item Includes Neatly Dressing Of Cables Marking Wiring Tree Etc. The Material Required For Dressing /Lacing Will Be Arranged By Contractor At Its Won Cost. The Work Is Required To Be Done Systematically And With Due Precaution During The Night Block Of 2.00-2.30 Hrs Eachorwithinthetimethatmaybeallowed.Theexcavationworktobedonecarefullywithout Damagingthecablestoavoidunduefailures.(Terminationchargeswillbegivenseparately)Note: Proportionate Payment Will Be Made If Cable Is Of Other Length. 2/6/12/19/24/30 Core Signalling Cable/4 Or 6 Quad/Pijf/Any Signalling/Telecom Cable(One No. Unit= One Cable Of 10 M Length). , Laying Of Rcc Half Round Cement Pipe Of Approximate Size (150/300 Mm Dia X 2 Meter Length) Inside The Trench After Laying Of Cable. Pipes Shall Be Placed As Per Directives Of Engineer , Paintingoftwocoatsofsyntheticenamelpaintoveronecoatofprimeronthe Following After Scraping & Cleaning Surface Wherever Necessary With Contractor Own Supply Of Paints. Whereverrequiredcontractorshallapplycoatingofepoxypaintalsoasperinstructionsofsite-In- Charge.Epoxypaintwillbesuppliedbyrailways.Note:-Thepaintandprimershouldbefromm/S Asianpaintsco.Ltd.,.Thepaintswillbeprimer(Is5660of1970)Thealuminumsyntheticblack Enamel (Is 2932 Of 1974) Brilliant White And Yellow Painting Two Coats Of Enamel Paint Over One Coat Of Primer. A) Apparatus Case Full Size. , Paintingoftwocoatsofsyntheticenamelpaintoveronecoatofprimeronthe Followingafterscraping&Cleaningsurfacewherevernecessarywithcontractorownsupplyof Paints.Wherever Required Contractor Shall Apply Coating Of Epoxy Paint Also As Per Instructions Of Site- In-Charge.Epoxy Paint Will Be Supplied By Railways. Note:- The Paint And Primer Should Be From M/S Asianpaintsco.Ltd.,.Thepaintswillbeprimer(Is5660of1970)Thealuminumsyntheticblack Enamel (Is 2932 Of 1974) Brilliant White And Yellow Painting Two Coats Of Enamel Paint Over One Coat Of Primer. B) Apparatus Case Half Size. , Lettering/Numberingofsignals,Pointmachine,Trackleadjunctionboxes,Block Joints, Apparatus Cases Etc. (Each Item To Be Taken As One Unit) This Work Will Be Carried Out As Per The Standard Practice Being Followed In Central Railway. , Lettering/Numberingterminationparticulars,Equipmentnamesetc.,Legiblyand Neatly Inside Location Boxes. A) Full Case. , Lettering/Numberingterminationparticulars,Equipmentnamesetc.,Legiblyand Neatly Inside Location Boxes. B) Half Case. , Schedule (C) - Provision Of Bpac & Double Distant Signal In Bd-Cndb Section On Bhusawal Division. (Non-Sor Items) , Supply Of Cable Route Marker As Per Rst/C/203 Of Frp. (Inspection By Consignee) , Designofalterationinexisting Signallingcircuits&Supplyofmodifiedsignalling Circuits Including Panel Diagram , Route Section Plan , Selection Table , Fuse & Negative Tag. Analysis , Contact Analysis , Relay Rack Arrangement And Wire Count Sheets Etc. In A3 Size.Completion Circuit Shall Be Plotted In Autocad. The Contractor Shall Initially Supply 2 Sets Of Circuits Duly Signed By The Circuit Designer Having Substantial Experience On Design Side For Making Such Circuits, Complete For Approvalofrailways.Railwayswillreturnonesetofcircuittothecontractordulyapprovedwith Alterations /Corrections, If Any. The Contractor/Railway Will Commission The Station With The Based On Theseapprovedcircuitdiagram.Thecontractorwillsubmitfinaltracing &Cd(Softcopyofdrg.) Based On Panel Testing,Break Test,Square Sheet Test Etc. To Railway For Their Final Approval.Complete In All Respects Along With 4 Sets Of Final . , Supply Of Tool Box Complete With Megger . (Inspection By Consignee) , Supply Of Trms Datalogging Dmm Fine Tip Multimeter Make-Rishabh 6016 Or Similar. (Inspection By Consignee) , Supplyoftruermsmultimeterflukemakemodel289orsimilar(Inspectionby Consignee) , Supply Of Bumpless Automatic Power Source Change Over Device Dc -20V-120V,Min 40 A (2 Input Sources) Model No. Pt-Rsa-Hl-Dc-04 Or Re-Sdsm-40 Or Similar. (Inspection By Rdso) , Installation Of Item Automatic Changeover Unit Of Signal/ Track /Point Supply Of 32A, Dc Consisting Of 3Tc44 Contactors Or Similar , Led Lamp, Push Button Terminals, Vsr, Polarity Switches. , Chase Cutting 500Mm Deep In Hard Rocky Area As Per Drg Ni- Core/S&T/Ald/Sk/579/04 Per Meter , Supply Of 24-40V/5A Dc-Dc Converter Module Compatible With Amara Raja Make Ips System As Per Specification No. Rdso/Spn/165/2012 (Ver. 3.0) Or Latest. Firms Offered Make/Brand- Self. (Inspection By Consignee) , Supply Of Cabinet With Wiring Arrangement For Dc-Dc Converter 08 Nos. Suitable For Station (Inspection By Consignee) , Deployment Of Manpower Like Unskilled Labour To Work In Emergencies Or As Requried During Cable Shifting,Finding The Existing Cable Route ,Shifting And Placing Of Material In Depot Etc , Deploymentofmanpowerlikeskilledlabourforsupervisionandtechnicalsupportin Emergencies Or As Required During Cable Shifting, Finding The Existing Cable Route Etc. , Supply Of Ganga Kaveri 110 Mm Diameter Pe 100 Hdpe Pipe (Detailed Description/Specification As Per Product # 1 Of Gem Contract No. Gemc-511687786912153 Dt.08/12/2023)(Inspection By Consignee)

Key Value

Document Fees
Refer document
EMD
INR 331977.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail