Tender For Comprehensive Maintenance To Strand Line Area Under Ge (C) Kolkata; 1 Demolition Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc, but excluding Ashlar Facings, dressed Stone Work and Pre-cast Concrete Articles of any descriptions, complete all as specified and as directed. 2 Demolition of cement concrete of any description andin any position not otherwise specifically provided for all as specified and directed. 3 Dismantling Reinforced Cement Concrete of any description and in any Position not otherwise specifically provided for, complete all as specified and as directed. 4 Taking down shutters of any description exc. 1.00 Sqm but n.exc 2 Sqm each and removing from site or to store as directed by Engineer in charge. 5 Taking down chowkhats or frames with shutters (without taking off shutter from frames) of any sizes nexc 1.5 Sqm complete all as specified and directed. 6 Taking down chowkats or frames with shutter (without taking off shutter from the frames) exc. 1.50 Sqm and n.exc 4 Sqm each complete all as specified and directed. 7 Taking down Cement Plaster of any description on Brick Walls, Concrete Surfaces including racking out joints, hacking for key, scrubbing down with Water, remove dust, debris/ rubbish, etc., complete all as specified and as directed. 8 Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing), and removing rubbish off the Premises, complete all as specified and as directed. 9 Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in mortar complete all as specified and directed. 10 Taking down Steel window and Ventilators of n.exc 1.5 Sqm including Grill/Guard Barsetc(upto 04 storied of building) complete all as specified and as directed. 11 Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. 12 Dismantling wrought iron or mild steel work viz steel window, ventilator, guard bars etc of any description not otherwise provided for complete all as specified and directed. 13 M&L Plain Cement Concrete type C-1, (1:3:6) (40mm graded crushed stone aggregate) as in Coping bed plate,hold fast etc,block benching,channeling slightly rounded or chamfered angle and throating including form work and finishing all exposed faces of cement concrete complete all as specified and as directed. 14 M&L Reinforced Cement Concrete Type B1 (1:2:4) (20mm graded crushed stone aggregate) as in Slab supported on Walls, complete all as specified and as directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. 15 M&L Brick work with fly ash bricks designation 75 (kgf/cm2) straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and directed. 16 S&F for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet reinforced with M.S. Square tube, fixing in opening as per Specifications and Drawings shown in MES Schedule Part-II, complete all as specified and as directed. 17 S&F Plain Colour Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing etccomplete all as specified and as directed. 18 S&F for 2nd class hardwood 30mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats as specified in SSR Part-I 2009.complete all as specified and directed. 19 S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides fitted to chowkhats complete all as specified and directed. 20 M&L Formwork toSoffits of suspended slab such as Roof slab, Floor slab, landings and similar works horizontal or sloping etc., not exceding 200mm thick ,flat rough finished surfaces of concrete, complete all as specified and as directed. 21 S&F Second Class Hardwood Plain, Solid, Straight Chowkats and Frames, Wrought, Framed rebated on the Solid, Rounded or Chamfered, put together with Glue, Pinned at Joints, complete all as specified and as directed. 22 S&F in repair Mild Steel Butt Hinges, size of Hinges 75mm, medium weight, Cold Rolled and fixed, complete all as specified and as directed 23 S&F in repair Mild Steel Butt Hinges, size of Hinges 100mm, medium weight, Cold Rolled and fixed, complete all as specified and as directed 24 S&F Aluminum anodized, barrel tower bolts of extruded section, 150 mm long and fixed with steel screws complete all as specified and directed. 25 S&F Aluminum alloy Handle 150mm long, Extruded Section, Fabricated type, anodized and fixed, complete all as specified and as directed. 26 S&F 300 mm long Aluminum alloy, anodized, Sliding Door Bolt with Hasp, Staple (Bolt type) and Fixing Clips of Sheet, Cast or Extruded Sections and Fixing Bolts and Sliding Bolts of Extruded Sections or Cast-Aluminum alloy and fixed, complete all as specified and as directed. 27 S&F in repair 300 mm long Aluminum alloy, anodized, Sliding Door Bolt with Hasp, Staple (Bolt type) and Fixing Clips of Sheet, Cast or Extruded Sections and Fixing Bolts and Sliding Bolts of Extruded Sections or Cast-Aluminum alloy and fixed, complete all as specified and as directed. 28 S&F in repair Mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete complete all as specified and as directed. 29 M&L for TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (anealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 30 S&F for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc. and similar work complete all as specified and directed. 31 M&L Mild Steel Flat Iron 25 x 3 mm, as in Holdfast for Door, Window Frames or Chowkats etc., cut to length or drilled hole and fixed with Screw, etc., grade of Steel conforming to Fe-290 Gde E-165, complete all as specified and as directed. 32 Supply and fix in repair aluminium anodised (powder coated) Three track sliding window frame with shutters with ( 2 nos glazed and one wire gauzed shutter)including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete andglazing with and including 5 mm thick tinted glass to aluminium frame work using rubber gasket and including stainless steel wire cloth of 0.36 mm dia & average width of aperture 1.40mm with staple or suitable fillets wire mesh fitted with screws and washers etc with the following section of frame and shutter (A) Sections for shutter (i) H section 39 x 20 x 1.50 mm thick (ii) Interlock section 39 x 20 x 1.50 mm thick (iii) Edge & Bottom section 41 x 20 x 1.50 mm thick(B) Section for frame (i) Top & Sides 123 X 29.70X 1.50mm not less than 1.30 Kg /RM(ii) Bottom 123 X 29.70 X 1.50mm not less than 1.502 Kg /RM complete all as specified and directed . 33 S&F in repair Powder coated (minimum thickness of powder coating 50 micron) Anodised aluminium frame for ventilators with one or more rebates including joining cleat for fixing ,glazing clips, rubber packing, anodised aluminium snap on beading for fixing glass panes in frames etc.complete with following specification.(a) Alu frame of size 63.5 mmx38.1 mm of thickness 1.70 mm of wt 0.901 Kg/Rm(b) Rail & Stilesize 63.5 mmx38.1 mm of thickness 1.70 mm of wt 0.901 Kg/Rm .(c) Std Alu C channel sec for Louvrs of 0.092 Kg/Rm .(d) 4.8 mm thick frosted sheet glassNote:- All ventilators/louvers memberincluding fitting & fixture shall be deem toincluded in the rate. Only measure opening size of ventilators/louvers 34 S&F steel window with side hung shutter including projection type hinges with steel handles, and steel peg stay with glazing bars dovetailed or welded complete all as specified. 35 S&F steel window with side hung shutter including projection type hinges with steel handles, and steel peg stay without glazing bars dovetailed or welded complete all as specified. 36 S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified. 37 M&L for Petty Repairs to any type of steel windows/ ventilator of any description in any situation (taking down & refixing in the same opening if required at site ) by Resecuring, easing, adjusting, changing the builders hardware position ,tightening, welding etc & re-fixing of builders hardwares like wire gauge,glass pane,beading, handles, stays, projecting type hinges/ friction / box type hinges,slot pin etc to make in proper smooth functioning (proper closing, opening) etc with entire satisfaction of Engineer-in-charge & applying two coats of synthetic enamel paint over one coat of red oxide primer on frame& shutter complete all as specified and directed. Note : 1. Unit rate quoted by tenderer shall included for use of all scaffolding, trestles, ladders, cradles etc, hoisting, lowering and protective measures etc up to four storeys height of bldgs. 2.Replacement of wire gauge & glass pane if required shall be measured and paid separately. Replacement of other builder hardware if required shall be deemed to be included in rate quoted by tenderer 38 M&L for Repairs to any type of wooden joinery works of shutters, shelf etc such as door, window, Ventilator,cupboards of any description in any situation by taking down & refixing in the same opening including Resecuring,easing, adjusting ,refixing builders hardware butt hinges,tower bolts,handles,sliding door bolts,rat tail,lock,ball catches,knobs,hasp & staple,peg set,doorstopper,piano hinges,door cill strip etc wiremess,glass pane in same/other position,renewal of screws,welding (if required) etc,wooden beading & tightening of GI/steel wiremesh etc making smooth functioning (for proper closing ,opening) etc with entire satisfaction of Engineer-in-charge complete all as specified and directed 39 M&L Prelaminated particle board 18/19mm thick as in cup board shutter and Shelf, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame works including taking down old unserviceable particle board complete all as specified and as directed. 40 M&L Non-skid Ceramic Coloured Tiles, 7.0mm to 8.0mm thick (square/rectangular), area of each tile exc 0.11 sqm but not exc 0.18 sqmin Floors, etc. Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over 15mm thick screed bed (1:6) in cement mortarcomplete all as specified and as directed. 41 M&LColoured non skid ceramics tiles, joint free 7 to 8mm thick (square/ rectangular), area of each tile exc 0.11 sqm but not exc 0.18 sqm on Vertical Surfaces such as Skirting, Dados, Risers to Steps, etc., Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over and including 10mm thick backing layerin cement mortar (1:4) complete all as specified and as directed. 42 M&L Glazed Ceramic Coloured 450 x 350 x 7.0mm/350 x 200 x 7.0mm thick on Vertical Surfaces such as Skirting, Dados, Risers to Steps, etc., Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over and including 10mm thick backing layerin cement mortar (1:4) complete all as specified and as directed. 43 M&L Granite (of any type) Work (Table rubbed and polished) 18 to 20 mm thick, in Steps, Cooking Platforms and like, Set in Screed bed of 20mm thick in Cement Mortar 1:4 including Pointing in White Cement 1:2 using Marble Dust with admixture of Pigment to match with Shade of Granite including Cutting and Polishing including half round edges, complete all as specified and as directed. 44 S&F Machine cut kota stone slab flooring 20-25mm thick (size 550mmx550mm) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and granite finish polishing complete over 20mm thick 1:6cement mortar screed bed complete all as specified and as directed. 45 S&F Machine cut kota stone slab flooring 20-25mm thick (size 550mmx550mm) Vertical Surfaces such as Skirting, Dados, Risers to Steps, etc. laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and granite finish polishing complete over 20mm thick 1:6cement mortar screed bed complete all as specified and as directed. 46 M&L Cement Concretetype C 2(1:3:6) using 40mm graded crushed stone aggregate 75mm thick as in Plinth Protection, etc. laid in alternate Bays, finished Concrete Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed. 47 M&L for 5 mm thick rendering on brick or concrete surfaces of wall in CM 1:3 and finished even and smooth without using extra cement complete all as specified & directed. 48 M&L Rendering15mm thick in Cement Mortar 1:6 on Brick Walls or on Concrete Surfaces, finishing plastered surfaces Even and fair without using Extra Cement complete all as specified and as directed. 49 M&L 20 mm thick rendering in cement mortar (1:4) on fair faces of brick or concrete externalsurfaces in two layers (each 10mm thick) finished even and smooth without using extra cement using water proofing compound on top layeras per manufactures instruction on external wall surface upto height of 4th storied bldg completeall as specified and directed.Note : WPC shall be measured and paid seperately 50 Supply only liquid water proofing compound (ISI marked) complete all as specified and directed. 51 M&L Preparing new Surfaces of Ceilng and applying Three Coats of White Wash, complete all as specified and as directed. 52 M&L Preparing old decorated Plaster Surfaces of Wall and applying One Coat of white wash complete all as specified and as directed. 53 M&L Preparing old decorated Plaster Surfaces of Ceiling and applying One Coat of white wash complete all as specified and as directed. 54 M&L Preparing old decorated Plaster Surfaces of Wall and applying One Coat of oil bound distemper (any colour /tint) complete all as specified and as directed. 55 M&L preparing new plastered surfaces of wall and and applying Two Coats of Distemper Oil Emulsion over a coat of primer over complete all as specified and as directed. 56 S&F 3mm thick sheet glass, selected quality and glazing with oil putty in squares n exc 0.5 sq. m in each panecomplete all as specified and directed. 57 S&F 3mm thick frosted glass, selected quality and glazing with oil putty in squares n exc 0.5 sq. m in each panecomplete all as specified and directed. 58 M&L in repair for 4 mm thick Sheet glass, ordinary quality and glazing with oil putty in square in not exc 0.5 sq.m in each pane, if required fixing with MS beading 10mmx01mm including welding, glazing pins etc or wooden beading etc if required including necessary scaffolding up to four storeys height of bldgs complete all as specified and directed. 59 M&L in repair for 4mm thick figured glass, pin head type and glazing with oil putty in square not exc 0.5 sqm in each pane if required fixing with MS beading 10mmx01mm including welding, glazing pins etc or wooden beading etc if required including necessary scaffolding up to four storeys height of bldgs complete all as specified and directed. 60 M&L Complete removal of existing Treatment of old decorated Surfaces of Walls and applying Two Coats of Distemper Oil Emulsion over a coat of primercomplete all as specified and directed. 61 M&L Preparing new plastered surfaces of Walls and applying Two Coats of Exterior Emulsion Paint Weather Coat over a coat of alklai resistance Primer (as per Manufacturer’s instructions), complete all as specified and directed. 62 S&F in repair Stainless Steel Wire Cloth 0.36mm nominal dia of Wire and average width of aperture 1.40mm and fixed with Stainless Steel Wire Staplescomplete all as specified and as directed. 63 M&L Preparing old Wooden Surfaces of any description not otherwise decribed over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint (First quality), complete all as specified and as directed. 64 M&L Preparing old Steel Surfaces of any description not otherwise decribed over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint (First quality), complete all as specified and as directed. 65 Preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel plaint over a coat of red oxide all as specified and directed by Engineer-in-Charge. 66 Supply and Laying Steel Water Tubing 15mm Bore (dia), Galvanised, ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situation, including taking down old unserviceable tubes and deposit to store complete as all specified and as directed. 67 Supply and Laying Steel Water Tubing 20mm Bore (dia), Galvanised, ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situation, including taking down old unserviceable tubes and deposit to store complete as all specified and as directed. 68 Supply and Laying Steel Water Tubing 25mm Bore (dia), Galvanised, ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situation, including taking down old unserviceable tubes and deposit to store complete as all specified and as directed. 69 M&L for taking down and refixing of old Steel Water Tubing 15mm Bore (dia), and connections with all new Fittings such as bends, elbows, tees, short pieces, connectors, back nut, reducer, diminishing pieces, caps, unions and plugs etc but except Steel tube connection, in new or old position such as fixed on Walls, Ceiling or laid in Floors or any other Situation, cleaning the same or deposit to store complete as all specified and as directed. 70 M&L for taking down and refixing of old Steel Water Tubing 20mm Bore (dia), and connections with all new Fittings such as bends, elbows, tees, short pieces, connectors, back nut, reducer, diminishing pieces, caps, unions and plugs etc but except Steel tube connection, in new or old position such as fixed on Walls, Ceiling or laid in Floors or any other Situation, cleaning the same or deposit to store complete as all specified and as directed. 71 M&L for taking down and refixing of old Steel Water Tubing 25mm Bore (dia), and connections with all new Fittings such as bends, elbows, tees, short pieces, connectors, back nut, reducer, diminishing pieces, caps, unions and plugs etc but except Steel tube connection, in new or old position such as fixed on Walls, Ceiling or laid in Floors or any other Situation, cleaning the same or deposit to store complete as all specified and as directed.Note for item no. 69.00 & 71.00:- (i) Steel tube retrived from taking down item or issue from store shall be reused.(ii) Serviceable steel tube obtained shall be reused after cleaning.(iii) Un-serviceable steel tube shall be deposited to store. The same shall be the property of contractor and take over by contractor through Schedule of Credit. 72 S&F work in repair for 20mm outer dia of CPVC water tubes SDR 11 with all fittings SDR 11 and fixed complete to walls and ceilings or laid in floors including taking down of old pipe complete all as specified and directed 73 S&F work in repair for 25mm outer dia of CPVC water tubes SDR 11 with all fittings SDR 11 and fixed complete to walls and ceilings or laid in floors including taking down of old pipe complete all as specified and directed 74 S&F work in repair for 40mm outer dia of CPVC water tubes SDR 11 with all fittings SDR 11 and fixed complete to walls and ceilings or laid in floors including taking down of old pipe complete all as specified and directedNotes for item Nos.72.00 to 74.00:- Unit rate quoted by tenderer shall included for use of all scaffolding, trestles, ladders, cradles etc, hoisting, lowering and protective measures etc up to four storeys height of bldgs. 75 S&F in repair PVC (SWR) Soil, Waste and Ventilating Pipe 110mm bore (dia), single socketed, in any length with Rubber Ring Joints fixed to Walls, complete all as specified and as directed. 76 S&F Pillar taps fancy type15mm bore of PTMT any colour screwed for iron pipe & fixed. (min weight 15mm-120gms) as in repaircomplete all as specified and directed. 77 S&FAngle stop valve 15mm bore of PTMT any colour screwed for iron pipe & fixed. (min. weight 15mm-90gms) with PTMT flange as in repaircomplete all as specified and directed. 78 S&F Bip tap with nozzle 15mm bore standard of PTMT any colour screwed for iron pipe & fixed (min. weight15mm-95 gms) as in repaircomplete all as specified and directed. 79 S&F Towel rail 600mm long of PTMT with chromium plated brass screws and wooden/plastic cleats minimum weight 190 grams as in repair complete all as specified and directed. 80 S&F Swivel shower with shower arm 15mm size,195mm long with bend of 45 degree with flange of PTMT any colour as in repaircomplete all as specified and directed. 81 S&F PTMT Grating Doom of 140mm size (Min weight 50 grms) and fixed-in-repairs, complete all as specified and as directed. 82 S&F PTMT Ball Valve 15mm dia having mini -mum weight 210 Grams, high pressure with epoxy coated Aluminium Rod and high density Plastic Ball, screwed for Iron Pipe and fixed as in repair, complete all as specified and as directed. 83 S&F PTMT Ball Valve 20mm dia having mini -mum weight 210 Grams, high pressure with epoxy coated Aluminium Rod and high density Plastic Ball, screwed for Iron Pipe and fixed as in repair, complete all as specified and as directed. 84 S&F PTMT Ball Valve 25mm dia having mini -mum weight 210 Grams, high pressure with epoxy coated Aluminium Rod and high density Plastic Ball, screwed for Iron Pipe and fixed as in repair, complete all as specified and as directed. 85 S&F in petty repair 32mm dia PVC flush pipe polyethylene of low or high density of PVC including jointing to any type WC for any type/size/make of low level flushing cistern and making floor with matching existing surface including all necessary fixing arrangement complete all as specified and directed. 86 S & F in repair for Waste fittings (coupling) 32mm bore of PTMT for steel sinks, basins, urinal etc with long screwed shanks and fly-nuts and washer complete all as specified and directed 87 S & F in repair for Waste fittings (coupling) 40mm bore of PTMT for steel sinks, basins, urinal etc with long screwed shanks and fly-nuts and washer complete all as specified and directed 88 S&F Cast Iron Soil, Waste and Vent Pipes 100mm bore (dia), Sand Cast, in any Length with or without Ears, with Cement Joints in Cement Mortar 1:1, fixed to Walls, including takind down ole unserviceable pipe complete all as specified and as directed. 89 S&F in repair for Cast iron 100mm bore Branch pieces, double (equal or unqual), ordinary or inverted (spigot or socket type) or with parallel branches or fitted with oval access doors complete all as specified and directedNote:- Unit rate quoted by tenderer shall included for use of all scaffolding, trestles, ladders, cradles etc, hoisting, lowering and protective measures etc up to four storeys height of bldgs. 90 S&F work in repair for Cast iron 100mm bore bend any radius complete all as specified and directedNote:- Unit rate quoted by tenderer shall included for use of all scaffolding, trestles, ladders, cradles etc, hoisting, lowering and protective measures etc up to four storeys height of bldgs. 91 S&F PVC (SWR) 110mm bore Branch pieces (Single Y), (equal or unqual), ordinary or inverted (spigot or socket type) or with parallel branches or fitted with oval access doors as in repair complete all as specified and directed. 92 S&F PVC (SWR) 110mm bore Branch pieces (Double Y), (equal or unqual), ordinary or inverted (spigot or socket type) or with parallel branches or fitted with oval access doors as in repair complete all as specified and directed. 93 S&Fin repair for PVC (SWR) 110mm bore bend any radius complete all as specified and directedNote for item No.91.00 to 93.00:- Unit rate quoted by tenderer shall included for use of all scaffolding, trestles, ladders, cradles etc, hoisting, lowering and protective measures etc up to four storeys height of bldgs. 94 S&F 32mm bore PVC waste pipe flexible type including all cups and sockets with minimum length 800mm for any type/make/size for stainless steel sinks, basins,urinal etc as in repair complete all as specified and directed. 95 S&F Rotational Moulded Polyethylene (HDPE) Water Storage Tank 500Litre Capacity (Cylindrical Vertical with Closed Top), Black in Colour, Three Layered Construction, hoisted and fixed in Position all specified in MES Schedule Part-I including provision of 25mm x 100mm GI nippples with check nuts for inlet, outlet wash,PTMT Ball Valve 25mm dia having mini -mum weight 210 Grams, high pressure with epoxy coated Aluminium Rod and high density Plastic Balland overflow pipe including Lowering of old/unserviceable Water Storage Tank of any description, complete all as specified and as directed. 96 S&F Rotational Moulded Polyethylene (HDPE) Water Storage Tank 1000Litre Capacity (Cylindrical Vertical with Closed Top), Black in Colour, Three Layered Construction, hoisted and fixed in Position all specified in MES Schedule Part-I including provision of 25mm x 100mm GI nippples with check nuts for inlet, outlet wash,PTMT Ball Valve 25mm dia having mini -mum weight 210 Grams, high pressure with epoxy coated Aluminium Rod and high density Plastic Balland overflow pipe including Lowering of old/unserviceable Water Storage Tank of any description, complete all as specified and as directed. 97 S&F Rotational Moulded Polyethylene (HDPE) Water Storage Tank 2000Litre Capacity (Cylindrical Vertical with Closed Top), Black in Colour, Three Layered Construction, hoisted and fixed in Position all specified in MES Schedule Part-I including provision of 25mm x 100mm GI nippples with check nuts for inlet, outlet wash,PTMT Ball Valve 25mm dia having mini -mum weight 210 Grams, high pressure with epoxy coated Aluminium Rod and high density Plastic Ball and overflow pipe including Lowering of old/unserviceable Water Storage Tank of any description, complete all as specified and as directed. 98 S&F Stainless Steel Sink with Drainage Board l.0mm thick Overall size 915mm x 460mm and Bowl size 410 mm x 355mm x 165 mm for Kitchen or Laboratory with Plugs, Washers,Brass chromium plated Waste Fitting 32mm dia,PVC waste pipe, a Pair of Cast Iron Brackets duly Painted including Cutting and Pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3 including Taking down/out unserviceable Sink and connected Items, complete all as specified and as directed. 99 S&F in repairs Stainless steel sink, 1.00mm thick for kitchen or laboratory, with plug, waste pipe, washers, including cantilever cast iron brackets, connecting union etc., overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm etc incl 40mm dia waste pipe complete including taking down/out unserviceable Sink and connected Items, complete all as specified and as directed. 100 S&F in repair stainless steel utencil plate rack (size 900 x 1200 x 200 mm) using 1.0mm thick sheet with all fittings accessories complete as directed. 101 S&F Vitreous China Colour Wash down Water Closet Pan (Pedestal Pattern) with p or s trap front or back inlet including fixing Bolts with and excluding 10 litre capacity low level Flushing Cistern matching with water closet colour with inlet ball valve float handle and providing 32mm dia PVC flush pipe including plastic water closet seat with flat bottom cover (coloured) fixed with mild steel chromium plated or aluminium hinging device including taking down old unserviceable one complete all as specified and as directed. 102 S&F in replacement Vitreous China White Squatting Pan ‘ORISSA’ Pattern, size 580x440mm with ‘P’ or ‘S’ Trap, Integral Foot Rest, providing Joints between Flush Pipe and Socket of WC Pan including Flushing Cistern and Flush Pipe, fixing with and including provision of cement Concrete Bedding complete all as specified and as directed. 103 S&F Vitreous China Wash Hand Basin 550x400mm in size, White (Flat Back or Angle Back Type) with 32mm dia Brass Chromium Plated Waste Fitting, a pair of Cast Iron Brackets duly painted including Cutting and pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3 including taking down/out unserviceable Wash Hand Basin and connected Items, complete all as specified and as directed. 104 S&F Brass chromium plated fancy type bib cock screwed for 15 mm bore of pipe etc. as in repair complete all as specified & directed. 105 S & F in repair for brass chromium plated two in one tap with Wall Flange screwed for 15 mm bore pipe complete all as specified and directedMake : Essco (MQT-512ANKN) or equivalent from list of make. 106 S&F Brass chromium plated fancy type pillar tap screwed for 15 mm bore of pipe etc.incl necessary fittings & fixtures as in repair complete all as specified & directed. 107 S & F work in repair for ABS body chrome plated shower rose 125mm size including fixing to steel pipe or union complete all as specified and directed 108 S&F Angular Stop cock concealed type ,15 mm dia cast copper alloy chromium plated fancy type with wall flange screwed for iron pipe etc. as in repair complete all as specified and directed. 109 Supply and fixing in repair 10 litre capacity low level PVC flushing cistern (any colour), syphonic action type, with inlet, ball valve, float, handle, fixed with cast iron bracket (of suitable size) and providing 32 mm dia PVC flush pipe and making all necessary connections complete as directed. 110 S & Fin repair for Plastic water closet seat, in any coloure as directed closed pattern with flat/recessed bottom, and cover and mild steel chromium plated or aluminised hinging device for pedestal pan complete all as specified and colour as directed 111 S&F CP Towel Rail 600mm Long fixed with and including CP brass screws and wooden / plastic cleats complete all as specified and as directed. 112 S&F Mirror Bevelled Edge 600x450mm, Selected quality Glass, mounted on 6.0mm thick AC Building Board or Commercial Ply-wood and fixed to Wooden Plugs with Chro-mium Plated Brass Screws and Cup Washers including Taking down unserviceable Mirror, complete all as specified and as directed. 113 S&F PVC connection pipe 15mm size with PTMT nuts of length 600mm long as in repair complete all as specified and directed. 114 M&L for Repairs to any type of Aluminium Doors, AluminiumWindows, Aluminium Ventilators, Aluminium Louvers, Aluminium CB shutters etc of any description, in any situation by taking down & refixing shutter including replacement ofrubber neoprene packing, aluminum snap beading, screws & tightening, adjustment etc ,making smooth functioning (proper closing, opening) etc with entire satisfaction of Engineer-in-charge complete all as specified and directed. 115 M&L for Repair for joint leakage in steel water tube by replacing of GI elbow/socket/reducers/nipple/union/bend/tee of any length 15mm bore medium grade ISI mark of complete all as directed. 116 M&L for Repair for joint leakage in steel water tube by replacing of GI elbow/socket/reducers/nipple/union/bend/tee of any length 20mm bore medium grade ISI mark of complete all as directed. 117 M&L for Repair for joint leakage in steel water tube by replacing of GI elbow/socket/reducers/nipple/union/bend/tee of any length 25mm bore medium grade ISI mark of complete all as directed. Notes for item No.115.00 to 117.00: 1. Unit rate quoted by tenderer shall included for use of all scaffolding, trestles, ladders, cradles etc, hoisting, lowering and protective measures etc up to four storeys height of bldgs being external works of building. 2.Cost of taking down steel water tube & refixing old steel water tube and connection in new or old position with new fixing arrangment in walls, ceiling, floors etc Shall be included in the rates quoted by the contractor. 118 Repair for joint leakage in CPVC water tube by replacing of CPVCelbow/socket/reducers/nipple/union/bend/tee of any length 20mm nominal bore SDR 13.5 complete all as directed. 119 Repair for joint leakage in CPVC water tube by replacing of CPVCelbow/socket/reducers/nipple/union/bend/tee of any length 25mm nominal bore SDR 11.5 complete all as directed. Note: Notes for item No.118.00 to 119.00: 1. Unit rate quoted by tenderer shall included for use of all scaffolding, trestles, ladders, cradles etc, hoisting, lowering and protective measures etc up to four storeys height of bldgs being external works of building. 2.Cost of taking down & refixing of CPVC tube and connection in new or old position with new fixing arrangment in walls, ceiling, floors etc Shall be included in the rates quoted by the contractor. 120 M&L in repairs for leaking water in brass/CP bib tap, pillar tap, concealed stop cock, angle valve of any make/ description/size in any position by replacing the (brass spindle+brass jumper washer) ,tightening of fittings etc ,also removing air lock, blockage in water pipe line & make the all system fully functional to the entire satisfaction of Engr-in-Charge complete all as specified and directed 121 M&L in repairs for (PVC Syphon assembly (internal kit) for any type/size/make of low level flushing cistern,tightening of fittings etc & make the all system fully functional to the entire satisfaction of Engr-in-Charge complete all as specified and directed. 122 Cleaning of blocked kitchen trap / nahani trap / floor trap/ Water closet of any type / pattern with vaccum pump upto 1st manhole and making the drain channel fully functional by flushing with sufficient quantity of water to entire satisfaction of Engineer-in-Charge including cleaning of 1st manhole and removing the waste materials / sludge etc to a distance outside residential area and burying the same in a pit and spreading bleeching powder surrounding the area @ 1Kg/ Sqm and sealing the top with fine sand of suitable depth complete all as specified and as directed.Note:-(i) Cost of earth work in excavation required for digging the borrow pit and burrying the the waste materials / sludge in the borrow pit and sealing the pit with fine sand and spreadind of bleeching powder shall deemed to be included in the rate quoted.(ii) Any damged done by the Contractor during cleaning shall be make good by the Contractor at his own cost upto the satisfaction of Enginner-in-Charge. 123 Cleaning of existing cover/un-covered drains of any section and depth removal of sludge, rubbish and other foreign material and flushing with adequate quantity of water and deposit the sludge to a distance not exc. 50m complete all as directed by Engr-in- Charge.Note:-(i) Once cleaned the drain, the Contractor shall maintain the lines functional upto the date of Completion at his own cost.(ii) Any damged done by the Contractor during cleaning shall be make good by the Contractor at his own cost upto the satisfaction of Enginner-in-Charge. 124 Disconnecting existing tanksof capacity exc 250 but not exc 500 liters setting aside (or lowering, hoisting if required) for repairs & scrubbing cleaning, thoroughly removing all scale and dirt, mud sediments, silts etc from the internal surfaces of PVC/RCC water storage tanks (bottom and wall) by using brushes, bleaching powder and other cleaning materials as required and removing vegetation around the over head tank after opening tank cover, inlet, outlet etc and reconnecting with GI/CPVC tubing and re-fixing in position ,refixingthe tank including cover after cleaning in position , write date of cleaning by synthetic enamel paint on tankcomplete all and specified and directed. 125 Disconnecting existing tanksof capacity exc 500 but not exc 1000 liters setting aside (or lowering, hoisting if required) for repairs & scrubbing cleaning, thoroughly removing all scale and dirt, mud sediments, silts etc from the internal surfaces of PVC/RCC water storage tanks (bottom and wall) by using brushes, bleaching powder and other cleaning materials as required and removing vegetation around the over head tank after opening tank cover, inlet, outlet etc and reconnecting with GI/CPVC tubing and re-fixing in position ,refixingthe tank including cover after cleaning in position , write date of cleaning by synthetic enamel paint on tankcomplete all and specified and directed. 126 Disconnecting existing tanksof capacity exc 1000 but not exc 2000 liters setting aside (or lowering, hoisting if required) for repairs & scrubbing cleaning, thoroughly removing all scale and dirt, mud sediments, silts etc from the internal surfaces of PVC/RCC water storage tanks (bottom and wall) by using brushes, bleaching powder and other cleaning materials as required and removing vegetation around the over head tank after opening tank cover, inlet, outlet etc and reconnecting with GI/CPVC tubing and re-fixing in position ,refixingthe tank including cover after cleaning in position , write date of cleaning by synthetic enamel paint on tankcomplete all and specified and directed. 127 S & F in repair PVC tank lid/cover for water storage tank capacity of 250 to 500 ltrs to matching with existing tank with fixing arrangementcomplete all as specified and directed. 128 S & F in repair PVC tank lid/cover for water storage tank capacity of 501 to 1000 ltrs to matching with existing tank with fixing arrangementcomplete all as specified and directed. 129 S & F in repair PVC tank lid/cover for water storage tank capacity of 1001 to 2000 ltrs to matching with existing tank with fixing arrangementcomplete all as specified and directed. 130 S & F in repair 100mm dia CI grating with hole/without hole for waste pipe fixed over floor/nahani trap complete all as specified and directed 131 Cutting/uprooting of tree from walls of bldgs. up to extended rootand spraying of acidof required qtyat any location of bldg up to 4 storied & making good disturbedsurfaces with CM 1:4or cement concrete(1:3:6) type C1 using 20mm graded aggregate including necessary scaffolding/ through rope with safety belt for size oftree of girth 5 to 10 cmcomplete all as specified and as directed by Engr -in-charge. 132 Taking down point wiring (light, fan, socket and power complete including fixtures and fittings such as switches ceiling roses, pendents , regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody for refixing or for taking credit (credit for above items should be made as per conditions separately) and making good distrubed surfaces of walls, floors, etc. including cleaning all and specified and directed. 133 M&L for point wiring with PVC insulated unsheated stranded copper conductor cable FRLH/S of size 1.5 sq mm in and including PVC casing caping of required width with all necessary fittings with sunk cast iron /pressed steel terminal box of1.6mm wall thickness and 3 mm thick laminated sheet top cover for mounting switches including 1.5 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly for one light / ceiling fan/exhaust fan / bell controlled by one switch , one way complete all as specified and directed by Engineer incharge. 134 All as per item No.133.00 mentioned here-in-before but 3 pin 5 amps socket out let point same board with other switches of cables of 1.5 sqmm 135 All as per item No.133.00 mentioned here-in-before but for one 5 amp switch socket combination on independent board with cables of 1.5 sqmm size 136 All as per item No.133.00 mentioned here-in-before but using 2.5 sq mm size stranded copper conductor cable for one 16 amp switch socket outlet on independent board including 2.5 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth lead complete all as specified and directed by Engineer-in-Charge. 137 All as per item No.133.00 mentioned here-in-before but using 4 sq mm size stranded copper conductor cable for one 16 amp switch socket outlet on independent board or for AC Starter including 4 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth leadcomplete all as specified and directed by Engineer-in-Charge. 138 S&F lamp holder insulated body with back plate for batten fittings complete all as directed. 139 S&Fin repair lamp holder insulated body with back plate for batten fittings complete all as directed. 140 S & F switch piano flush type 5/6 Amps 230V AC one way complete all as specified and directed by Engineer-in-Charge. 141 S & F in repair switch piano flush type 5/6 Amps 230V AC one way complete all as specified and directed by Engineer-in-Charge. 142 S&F socket outlet 3 pin 5/6 Amps 230 volts flush type. complete all as specified and directed by Engineer-in-Charge. 143 S&F in repair socket outlet 3 pin 5/6 Amps 230 volts flush type complete all as specified and directed by Engineer-in-Charge. 144 S&F bell push flush type 5 Amps 230V complete all as specified and directed by Engineer-in-Charge. 145 S&F call bell, ding dong AC 230 volt single pole (ding dong type) complete all as specified and directed by Engineer-in-Charge. 146 S&F in repair call bell, ding dong AC 230 volt single pole (ding dong type) complete all as specified and directed by Engineer-in-Charge. 147 S&F ceiling rose surface bakelite 65x50mm single phase complete all as specified and directed by Engineer-in-Charge. 148 S&Fin repair ceiling rose surface bakelite 65x50mm single phase complete all as specified and directed by Engineer-in-Charge. 149 S&Fswitch socket combination2in 1 3 pin 6 Amps 230 volts flush type complete all as specified and directed by Engineer-in-Charge. 150 S&F in repair switch socket combination2in 1 3 pin 6 Amps 230 volts flush type complete all as specified and directed by Engineer-in-Charge. 151 S&F switch socket combination multipurpose 3 pin 10 and 20 Amps one switch complete all as specified and directed by Engineer-in-Charge. 152 S&F in repair switch socket combination multipurpose 3 pin 10 and 20 Amps one switch complete all as specified and directed by Engineer-in-Charge. 153 S&Fceiling fan regulator electronic Step type, solid state, 240 volts,complete all as specified and as directed 154 S&F in repair ceiling fan regulator electronic Step type, solid state, 240 volts,complete all as specified and as directed 155 S&F in repair ceiling fan regulator socket type, solid state, 240 volts,complete all as specified and as directed 156 S&F switch socket combination with box multipurpose 3 pin 10 and 20 Amps one switch complete all as specified and directed by Engineer-in-Charge. 157 S&F in repair switch socket combination with box 2in 1 3 pin 6 Amps 230 volts flush type complete all as specified and directed by Engineer-in-Charge. 158 Fixing only swithes, switch socket combination, ceiling rose, call bell and lamp holder of any capacity complete all as specified. Note:- Serviceable swithes, switch socket combination, ceiling rose, call bell and lamp holder shall be obtained from item No. 132.00 mentioned here-in-before. 159 Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-Charge. 160 Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge. 161 S & F LED bulb 9Watts 240V 50Hz 6500K b22 base in bulb holder complete all as specified and directed by Engineer-in-Charge. 162 S&F building security light pressure die cast housing with individual LEDs with modular secondary optics security light luminaires 35 watt LED with 50mm dia light grade GI pipe bent to shape of 45 1.5 mtr long and nuts bolts including fixing arrangement after taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge. 163 Supply and fix plug top 3 pin16A 240V Easy to carry, Non flammable & Durable Heavy duty , nickel plated brass terminals Long lasting polycarbonate plastic material complete all as specified and directed by Engineer-in-Charge. 164 S&Fplug and socket in sheet metal enclosures with two pin and earth plug and socket complete with and including MCB SP 20 Amps 240 volts heavy duty all as including taking down of old unsv one specified and as directed by Engr-in-charge 165 S&F A C starter unit consisting of one 25 Amp capacity starter, one 240 V 25 Amps 10 KA SPN MCB, one 25 Amps socket and one 25 Amps plug top prewire complete all as specified and directed by Engineer-in-Charge. 166 S&F in repair A C starter unit consisting of one 25 Amp capacity starter, one 240 V 25 Amps 10 KA SPN MCB, one 25 Amps socket and one 25 Amps plug top prewire complete all as specified and directed by Engineer-in-Charge. 167 Taking down unserviceable rusted / damaged MCB DBs of any type and way along with any type MCB and keeping serviceable MCB in safe custody in re-use in the work and making good to the distubed surfaces of walls etc. complete all as specified and as directed. 168 S&F MCB TPN DB made up with sheet metal, phosphorised, power coated, neutral link, earth bar and din rail, 4 way TPN with 200 amps rated bus bar, 415 volts complete all as specified and as directed. 169 S&F MCB SPN DB made up with sheet metal double door, phosphorised, power coated, neutral link, earth bar and din rail, 4 way with 200 amps rated bus bar, 240 volts complete all as specified and as directed. 170 S&F sheet metal enclosure for DBs when MCBs to be used 8 way single pole and neutral double door with 200 amps rated bus bar complete including connection all as specified. 171 S&F isolator 63 Amps 415 Volts FP with rapturing capacity 10KA including taking down of old one complete all as specified and directed by Engineer-in-Charge. 172 S&F MCB 6 to 32 amps 240 volts 10KA single pole complete all as specified. 173 Fixing only MCB 6 to 32 amps 240 volts 10KA single pole complete all as specified. Note:- Serviceable MCBs shall be obtained from item No. 167.00 mentioned here-in-before. 174 S&Fin repair MCB 6 to 32 amps 240 volts 10KA single pole complete all as specified. 175 S&F MCB DP 40 to 63 amps 240 volts 10KA breaking capacity complete all as specified. 176 Fxing only MCB DP 40 to 63 amps 240 volts 10KA breaking capacity complete all as specified. Note:- Serviceable MCBs shall be obtained from item No. 167.00 mentioned here-in-before. 177 S&Fin repair MCB DP 40 to 63 amps 240 volts 10KA breaking capacitycomplete all as specified and directed by Engineer-in-Charge. 178 S&F sub main wiring two run of single core PVC insulated unsheathed stranded copper conductor of size 10 sqmm & one run of PVC insulated unsheathed stranded copper conductor of size 10 sqm as earth lead drawing into rigid non metalic PVC conduit of size 20mm dia including taking down old unsv complete all as specified. Note: Two run of 10 sqmm cable and one run of 10 sqmm cable will be measured as single length. 179 S&F sub main wiring two run of single core PVC insulated unsheathed stranded copper conductor of size 6 sqmm & one run of PVC insulated unsheathed stranded copper conductor of size 6 sqm as earth lead drawing into rigid non metalic PVC conduit of size 20mm dia including taking down old unsv complete all as specified. Note: Two run of 6 sqmm cable and one run of 6 sqmm cable will be measured as single length. 180 S&F sub main wiring two run of single core PVC insulated unsheathed stranded copper conductor of size 4 sqmm & one run of PVC insulated unsheathed stranded copper conductor of size 4 sqm as earth lead drawing into rigid non metalic PVC conduit of size 20mm dia including taking down old unsv complete all as specified. Note: Two run of 4 sqmm cable and one run of 4 sqmm cable will be measured as single length. 181 Taking down and opening out the ceiling fan/wall mounted upto1200/1400 mm sweep for inspection, removing bush / bearing, cleaning of bush / bearing, replacement of unserviceable / worn out bearing / bush, shaft, removing burnt out coils from the slots, cleaning and repairing of slots complete including materials like split pin, rubber reel etc and reassembling and refixing of fan complete with and including minor Spares, if any required complete all as specified and as directed. Note : Spare parts shall be measured & paid separately. 182 Rewinding of ceiling fan motor with super enamelled copper winding wire of suitable size & varnishing including testing of fan after rewinding complete all as specified. 183 Supply only ball bearing suitable for 1200/1400mm sweep Ceiling fan of any make. 184 Supply only capacitor of 2.5 mfd for Ceiling Fan 185 Supply only gun metal bush of suitable size for ceiling fan of sweep 1200mm/1400mm as per existing one complete. 186 Supply only shafts for ceiling fan suitable for 1200mm sweep 187 Supply only PVC connector for Ceiling Fan 188 Supply only fan blades for Ceiling fan suitable for 1200mm sweep/1400mm sweep. 189 Supply only nuts, bolts, for Ceiling fan 190 M&L for painting of ceiling fan/wall fan/exhaust fan of any size and sweep complete with synthetic enamel paint by spraying including filling with cavities with filler, after cleaning all dust etc complete all as specified and directed by Engineer-in-Charge. 191 Taking out the BLDC Ceiling fan/ wireless remote PCBA (controller bd) and repair the same and refixing the same in original position either in fan or remote complete all as specified and directed by Engineer-in-Charge. 192 Supply only BLDC PCBA(controller Bd) 193 Supply only BLDC Ceiling Fan Stator Ferrite Magnet Ring 12/14/16 Poles 194 Supply only BLDC rotor magnetic coil of 12/14/16 poles 195 Supply only plastic 12 pole stamping ring 196 Supply only remotes for BLDC ceiling fan.Make as per sample 197 Taking down and opening out the exhaust fan upto 400 mm sweep for inspection, removing bush / bearing, cleaning of bush / bearing, replacement of unserviceable / worn out bearing / bush, shaft, removing burnt out coils from the slots, cleaning and repairing of slots rubber reel etc. reassembling and refixing of fan complete including all as specified and as directed. 198 Rewinding of fan motor with super enamelled copper winding wire of suitable size & varnishing including testing of fan after rewinding complete all as specified. 199 M&L for painting of exhaust fan of any size and sweep complete, in situ with approved colour synthetic enamel paint by spraying including filling with cavities with filler, one coat after cleaning all dust etc. 200 Supply only bush suitable for exhaust fan. 201 Supply only ball bearing suitable for exhaust fan. 202 Supply only capacitor 2.5 mfd for exhaust fan. 203 Taking down unserviceable exhaust fans and supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete as directed.Note:- Old Unserviceable fan/ meter/ geyser shall be deposited to store. 204 S&F in replacement MS louvers of exhaust fan upto the size of 400mm sweep upto four storey building complee including arrangement of scaffolding for fixing of louverswith all nuts, bolts and washers and finishedproperly with cementwork as per existing complete all as specified and as directed by engr in charge 205 Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete as directed. 206 Taking down carefully unserviceable geyser of any type and make from site after disconnections of water & electrical connections & carrying out to MES store yard for inspection and thereafter to workshop for repair & replacement of components such as heating element, thermostate, cable, neon lamp, plugtop, outer casing, plates & repair work to apparatus plate, copper tank,split plate including de-scaling of water tank etc and carrying back to MES store yard for testing and refixing at site and making water & electrical connection on completion and all as directed. 207 M&L for painting of geysers 25 ltrs at site/at workshop duly with one coat of synthetic enamel paint (white) including preparation of surfaces with brush, cleaning agents as required of 25 Ltr capacity and its front with best quality paint all as directed and specified by Engr-in-Charge 208 M&L for brazing/gas welding of inner container copper of 25 ltrs /50 ltrs capacity and any make and making leak proof all as directed. 209 Supply only following spares for geysers:-Heating element 1.5KW including rubber gasket ISI marked suitable for existing geysers. 210 Heating element 2.00KW including rubber gasket ISI marked suitable for existing geysers. 211 Thermostate for suitable existing geyser of 25/50 litrs capacity 212 Chromium plated copper pipe of length not less than 60cm including washers for incoming & outgoing hot & cold water connections as specified and directed by Engr-in-charge 213 Apparatus plate assembly complete for geyser of capacity 25/50 litrs capacity. 214 Outer casing made out of 22 SWG MS sheet suitable for geyser of capacity 25 litrs. 215 Storage tank fabricated from copper sheet gauge suitable for geyser of capacity 25 ltrs of make as specified and approved. 216 Split plate bottom cover made out of 22 SWG MS sheet suitable for 25 litrs capacity geyser 217 Split plate top cover made out of 22 SWG MS sheet suitable for 25 litrs capacity geyser 218 Insulating material glass wool 219 Element holding brass stud 220 Element holding MS clamp 221 Fusible metal plug 222 Neon lamp round/square with connection lead 223 Non return valve for 25 liters geyser inlet 224 M&L testing and installation of factory made (CPRI approved) indoor type dust & vermin proof MCB box made out of 2.00 mm CRCA steel sheet of size 0.40x0.30x0.10m with suitable size angle iron grouted in wall including 100 amps aluminium bus bar having opening of one isolator and two nos of SPN and one MCB incl internal wiring with PVC insulated single core cables of copper conductor duly numbered with tags for the circuits with hinged single door shutters (front and rear), cubicle type locking arrangementincluding two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. 225 Supply, installation testing and commisisioning bus bar chamber CPRI type tested minimum size 0.6x0.4mx0.15m double door IP 54 rating with bus bar of 200Amps capacity with locking arrangement including two coats or synthetic enamelled paint over a coat of red oxide primer both internally & externally after taking down old unserviceable one and removing the wooden cover and making good the disturbed surface with connection through existing serviceable MCCB complete all as directed by engr-in - charge. 226 Supply and fix in repairs /replacement of self adhesive PVC Electrical Insulation tape of size 1.8cmx6.5mx0.125mm mix colour box in a packet of 12 roll complete all as specified and dircted. Note- Insulation tape should be ISI marked. 227 S&F MCCB, 63 Amps, breaking capacity 16kA, four pole with thermal and magnetic release adjustable type including necessary connection including taking down old unserviceable one complete all as specified and as directed. 228 M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI wire proected by 15 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified anddirected. 229 NOTE FOR ALL ITEMS OF BOQ:- All retrived servicable and un-serviceable materials shall be deposited in MES store yard and handed over to contractor, if catered for in Schedule of credit.