| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soilas specified and directed. |
| 2 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 mas specified and directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cmas specified and directed. |
| 4 | Demolition of Brick work built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stone work and precast concrete articles complete all as directed. |
| 5 | M&L for rendering 10mm thick on fair faces of brick or concrete in CM 1:6 finishing even and smooth with out using extra cement all as specified and directed. |
| 6 | M&L for Brickwork with sub-class `B\" old sizebricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 all as specified and directed. |
| 7 | M&L for Cement concrete 1:4:8 type D-2 (40mm graded stone aggregate)in foundations, filling and mass concrete |
| 8 | Providing, cement concrete in roof type B-2(1:2:4) 20mm graded stone aggregate , in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 9 | S&F in of 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls or laid in floors as in soil, waste and pipes including dismantling of old pipes all as specified. |
| 10 | Cement concrete in surface channels and drains type C-2 1:3:6(40mm graded stone aggregate) |
| 11 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc. |
| 12 | M&L for pre-cast RCC 1:2:4, type B-1 using 20mm graded stone aggregates as in cover slabs sets in CM 1:6 including all necessary formwork. Exposed surfaces of concrete shall be finished even and smooth without using extra cement complete all as spd and as directed. |
| 13 | M&L for TMT steel bars 8mm dia cut to length bent to shape required including cranking, hookin ends and binding with mild steel wire (annealed not less than 0.90mm dia) complete all as spd and as directed. |
| 14 | S&F 10000 litre fibre reinforced plastic tanks/sumps of food grade virgin plastic non porous to roots and impermeable to chemicals |
| 15 | M&L for preparation of newly plastered surfaces of ceilings and applying three coats of white wash all as specified and directed. |
| 16 | Surface dressing n exc 15 cm deep in soft / loose soil all as specified and directed. |
| 17 | M&LHardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface |
| 18 | M&L 100 mm thick cement concrete type D-2 1:4:8 (40mm graded stone aggregate) as in sub base complete all as specified and as directed. |
| 19 | M&L 100 mm thick cement concrete type B-2 1:2:4 (40mm graded stone aggregate) as in floor Finishing cement concrete surface even and smooth with out using extra cement complete all as specified and as directed. |
| 20 | M&L for preparing new or previously untreated surfaces of steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed. |
| 21 | Supplied and fixed pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws etc complete all as specified, directed and as per manufacturer\"s instructions. |
| 22 | Supplied and fixed Rolled mild steel sections conforming to Fe-290 (Gde E-165) as in main and cross beams, hip and jack rafters; purlins where connected to common raftersfixed with angle cleats or other connecting plates complete all as spd and as directed. |
| 23 | Supplied and fixed 1.6mm tk Mild steel, plain, black sheet covering to door shut ters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required sheeting is welded to frame complete all as spd and as directed. |