| 1 | Sch \"A\" Part -I (B/R Work):-Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified & directed |
| 2 | Excavating over areas n.exc 1.5m deep and getting out in soft / loose soil complete all as specified & directed |
| 3 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out complete all as specified & directed |
| 4 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified & directed |
| 5 | Removal excavated soil n.exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified & directed |
| 6 | M&L for cement concrete type D2 1:4:8 (using 40mm graded stone aggregates) as in foundations, filling and mass-concrete complete all as specified & directed |
| 7 | M&L for Brickwork with subclass ‘B’ old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified & directed |
| 8 | M&L for precast reinforced cement concrete in baffle walls or manhole covers type B1 1:2:4 (using 20mm graded aggregates) including necessary metal lathing or TMT bar having weight not less than 2% by volume of RCC inside and use and waste of formwork kept in position in brick masonry and set in cement mortar 1:3 as directed complete all as specified & directed |
| 9 | M&L for 15mm thick rendering in CM 1:4 for internal / external wall surfaces and finishing surface even and smooth without using extra cement complete all as specified & directed |
| 10 | M&L provinding cement concrete (1:2:4) B-1 as in copings / bearing course over brick walls etc and like complete all as specified. |
| 11 | M & L for 50mm thick cement concrete type B1 (1:2:4) using 20mm graded stone aggregate as in floor of septic tank finishing surface even and smooth without using extra cement etc all as specified and directed complete. |
| 12 | M&L for cement concrete 1:3:6 type C2 (40mm graded stone aggregates) as in surface channels and drains complete all as specified & directed |
| 13 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified & directed |
| 14 | S&F cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles exc of weight exc 5 Kg in each complete all as specified & directed |
| 15 | S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework ofwater tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified & directed |
| 16 | M&L for preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth, not otherwisedescribed and applying two coats of shythetic enamel paint over a coat of red oxide primer complete all as specified & directed |
| 17 | M&L for preparation of new or previously untreated plastrered surfaces and applying two coats of cement based paint complete all as specified & directed |
| 18 | S&F in repairs PVC (SWR) pipes 110 mm single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified & directed |
| 19 | M&L for 150mm bore reinforced concrete pipes, class NP2, laid and jointed complete with colars laid in trenches and jointed as specified complete |
| 20 | M&L for concrete bed to drain pipes for 150mm dia RCC NP-2 pipes using PCC 1:4:8 type D-2 (using 40mm graded aggregates) including forming cradles complete all as specified and directed. |
| 21 | M&L Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 typeB-l smooth finished, and reforming benching as required for 150mm dia of pipe complete all as specified & directed |
| 22 | Sch \"A\" Part -I (E/M Work):-Supply and fixing of 200W LED street light fixture made out of epoxy powder coated die cast aluminium housing, weatherproof gasket, control gear accessories complete all as specified(Perimeter) |
| 23 | Supply and draw submain wiring with two single core 2.5 sqmm FRLS PVC insulated copper cable 1100 volts grade multistranded, unsheathed conductor drawn into PVC casing and capping and all necessary fittings including 2.5 sqmm multi strand FRLS PVC insulated copper wire for earth continuity conductor connected to common earth dollycomplete after taking down the old unserviceable wiring complete all as specified and directed. |
| 24 | Taking down and re-fixing serviceble street light 90 watt as per required location in station complete all as specified and directed. |