Replacement And Renovation Work Of Compound Illumination System At Maheshmati Rhe, Malda Attached To Electrical Subdivision No-Iii, Housing Directorate.- 1 Dismantling steel tubular/Rail/Strut embedded in CC foundation incl. excavation, filling of holes, restoring surface, loading at site and delivering, unloading, sorting, stacking properly at any place as per direction upto a lead of 1.6 km 2 Supplying and fixing 2 Way MCB SS enclosurewith IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection& provision for earthing attachment. along with Supplying and fixing 240V 32A DP MCB (Make: Legrand/Schneider/Siemens/ABB/L&T) of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 3 Supply & Delivery of 9 Mtr Steel Tubular Pole (Calcutta Poles/Jindal /Bansal/Transrail) as per specification Type 410 SP - 33 as overall length 9 mtrweight 164 KG with fixing the base plate as per direction of EIC incl Supply of base plate,CI cap with Pole having with 40 mm. dia 1.5 mtr. long detachable type G.I. Singlearm bracket, suitable for pole head. The arm bracket shall be properly welded with 15 mm. thick stifner plate of pole sleeve for strengthening incl. properly fixing arrangement with the pole by bolts. 4 Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with allaccessories to be fixed /projected from the wall of the building incl. making holes/providing clampingarrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts.average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. 5 Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km fromStore to work-site including filling up the excavated earth pit with shifted soil and ramming properly Upto 9.0 mtr. 6 providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) incl. drilled hole in pole suitable for alkathene/polythene pipe entry, for street light wiring, without Loop Box( 10 for exiting damage) 7 Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixedpaint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paintUpto 9.0 mtr. long poleOne coat of red lead/Zinc chromate priming.1st coat of synthetic enamel paint over the primer.2nd coat of synthetic enamel paint over the 1st coat. 8 Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthingterminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint. 9 Supply and Delivery of 45 Watt (Efficacy not less than 110 LPW with IP 66 protection, 10 KV SPD included) street light fitting in place of the existing fitting including taking down the defunt street light. (Make: Crompton CRP-409-45-57-SL_GL-NSG or its equivalent of Philips/Wipro/Jaquar) with NABL accredited lab with valid test certificate. 10 Supply and Delivery of 70 Watt (Efficacy not less than 110 LPW with IP 66 protection, 10 KV SPD included) street light fitting in place of the existing fitting including taking down the defunt street light. (Make: Crompton CRP-409-70-57-SL_GL-NSG or its equivalent of Philips/Wipro/Jaquar/Magik) with NABL accredited lab with valid test certificate. (42 for exiting pole) 11 Supply and Delivery of 120 Watt (Efficacy not less than 110 LPW with IP 66 protection, 10 KV SPD included) street light fitting in place of the existing fitting including taking down the defunt street light. (Make: Crompton CRP-411-120-57-SL_GL-NSG or its equivalent of Philips/Wipro/Jaquar/Magik) with NABL accredited lab with valid test certificate. ( from building) 12 Fixing only outdoor light Fitting by providing labour of different rated LED street light fitting as per the direction EIC. 13 Supply of 2 core10 sqmm of 1.1 KVgrade alluminium XLPE, PVC/ armouredLT cable( Make :Havells/ Polycab/ KEI/ Finolex/RR ) 14 Laying of 2 core10 sqmm cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish at an average depth of 75 mm in floor/pavement/wall etc. 15 Laying of one No. 2 core 10 sqmm cable in underground trench 460 mm wide x 760 mm average depth, with brick protection onthe top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed 16 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables of 2 core 10 sqmm cable. 17 Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :2 core 10 sqmm cable. 18 Supplying and Drawing 1.1 KVsingle core stranded FRPVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 22/0.3 (1.5 sqmm).( Loop Box to Fitting) 19 Supplying and Laying 19mm heavy gauge Polythene Pipe. ( Loop Box to Fitting) 20 Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By ISI-Medium GI pipe 21 Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required 32 mm dia 22 Hiring charges for mobile folding ladder at different sites for the above compound light work including transporation charges and providing 2 nos of unskilled labour for proper handing of the ladder and carring it 23 Supply and fixing of 230 V Timer DBwith steel sheet enclosure double door, phosphatised powder coated , neutral bar, Din Rail with IP-43 protection. i)1 no. 25A DP MCB (C Curve, 10 kA,), ii) 1 no. 24 hours programmable Digital Time Switch. (Cat no:-67DDTO make:- L&T/ or Similar)iii) 1 no. 32 A,1-Phase Power contactor.(Make:- L&T or Similar)iv) 1 no. Auto/ Manual bypass Changeover Switch v) Provision for earthing attachment including LED indication light for running condition and locking arrangement. Suitable DB size selection with internal wiring 6sqmm Copper wires along withProper Connection with Cu.Socketting endto be fixed maintaining recommended clearance. as directed by EIC.Make:-L&T/Legrand) 24 Supply & Fixingof 240V, 40 W LED decorative post-top luminarie complete with all accessories and equipped with IP65 Protection (Make- Crompton, LPTO - 40 - CDL - Mor equivalent model of Philipsj/wipro) on existing MS Pipe/Mini Pole as per direction of E.I.C 25 Supply & Fixingof 240V, 150 WFlood LED out door type light fittings complete with all accessories and equipped with IP66 Protection (Make:- Crompton TFS- 504 - 150 - 57 - 60 D - HL2 - GL NBK or equivalent model of Philips/Wipro) on existing MS Pipe/Mini Pole as per direction of E.I.C (For existing Ground Light) 26 Add. G.S.T.@ 18% (on Total from item no 1 to 25) to be calculated by bidder 27 Add. LWC.@ 1%to be calculated (on total from item no 1 to 25 + GST@18%) by bidder