}

Tender For Establishment Of Para Sports Arena At Krishnagiri District., krishnagiri-Tamil Nadu

Sports Development Authority Of Tamil Nadu has published Tender For Establishment Of Para Sports Arena At Krishnagiri District.. Submission Date for this Tender is 03-09-2025. Excavation Work Tenders in krishnagiri Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

50569038
Tender For Establishment Of Para Sports Arena At Krishnagiri District.
Tender
Indian
Tamil Nadu
Krishnagiri
03-09-2025

Tender Documents

Tender Details

Tender For Establishment Of Para Sports Arena At Krishnagiri District.; 1 Civil Work:-Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. 2 Providing Pre construction Anti termite treatment for the building including all chemicals as per standard specifications. Labour charges for preparing the areas for treatment spraying chemicals and other incidential charges etc., complete. The rate shall be inclusive ofgiving anti-termite treatment to the building for the following four stages including breaking the termite mounds making holes with crow bars at an intervel of 12to a depth of 8 in the periphery of building and pouring chemicals etc., complete as per ISI 6313-1981 and. The antitermite chemicals used should have 0.5% concentration with 3L solution for the entire operation etc. as directed by the Engineer incharge and including cost of chemicals labour transportion etc., 3 Cement Concrete 1:3:6 (One Cement, Three sand and Six broken stone jelly) using 40mm size hard broken stone jelly for dummy columns, excluding cost of centering shuttering reinforcement grills and fabrication charges but including curing etc. complete. (Reinforced Cement Concrete 1:2:4 for slab to be extended upto top of splashing with pressed tiles and future extension rods to be embedded in CC 1:3:6 (One Cement, Three Sand and Six hard broken stone jelly).Dummy columns should be at least 1 metre height) 4 Supplying and filling in foundation, basement, etc with filling M- sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 5 Providing and laying, spreading and compacting graded stone aggregates to Wet Mix Macadam 250 mm thick specification including premixing the materials with water at OMC in mechnanical mix plant carriage of mixed material by tipper to site laying in uniform layers with pavers in Sub Base/ Base course on well prepared surface and compacting with vibratory roller to acheive the desired density including cost of material, labour charges, rentals for machinery,fuel and all other incidental charges etc., complete as per clause 406 of MORTH Rev-5 (This Rate Is Applicable Only If Work Is Done During Night) 6 Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) 7 For column footing plinth beam bed blocks templates staircase, steps piers, raft beam, raft slab etc. 8 For Plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc. 9 Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification.(Contractor has to make his own arrangements for the supply of steel and binding wire) 10 Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 400 kg/mᶾ and maximum water cement ratio of 0.45, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers.The coarse and fine aggregates to be used should comply with the requirements of IS Standards.(No separate payment will be made by the Department for the excess usage of materials). 11 Ground Floor 12 Supply & Laying of Ferrocement cement concrete 1:1:2 (One cement, onesand and two aggregates) using 20mm size HBG stone jelly excluding centering shuttering and also cost of reinforcement - grill --- including casting, vibrating, curing etc., complete 13 Reinforcement cement concrete 1:1:2 (One cement, onesand and two aggregates) using 20mm size HBG stone jelly excluding centering shuttering and also cost of reinforcement - grill --- including casting, vibrating, curing etc., complete 14 Footing 15 Brick work in following Cement Mortar using Fly Ash Bricks of 230 x 110 x 75mm size conforming to IS: 12894-1989 Class designation not less 50 kg./ sq.cm. average compressive strength in cement mortar 1:5 for load bearing structures for foundation and basement and for superstructure including curing, etc., complete complying with standard specifiction. 16 Ground Floor 17 Brick partition walls of 11.50cm thickness using best quality Fly ashbricks of size 9 x 4-3/8 x 2-3/4 in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. 18 Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 19 Plastering the surface of walls with Cement Mortar 1:3 (One cement and Three sand), 20mm thick in all floors including curing etc., complete complying with standard specification and as directed by the departmental officers. 20 Special ceiling plastering 10 mm and finishing all RCC exposed surface such as RCC slabs, sunshades, canopies, staircase, steps, landing slabs etc., with CM 1:3 10mm thick including hacking the surface and providing necessory CM nosing, beading as per whereever necessary using the same mix etc., completer complying with standard specification and as directed by department officer. 21 Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat with Putty coatincluding thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. 22 Painting two coats of newly plastered wall surface with ready mixed Exterior emulsion paint of first class quality and of approved colour over a priming coatincluding thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. 23 Flooring with followingDesignedceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand)base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) 24 Dadooing walls with following best approved quality, Designed colour ceramic tilesof following sizes set in Cement Mortar 1:2 (One Cement and Two sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. 25 Paving the floor with best quality Double charged Vitrified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) 26 Paving the floor with pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) 27 Flooring with red oxide cement plaster, polished surface and thread lining curing,etc.,complete as directedby the Engineer-in-charge.BD-476 28 Finishing the floor with 20mm cement concrete (Ellis Patternfirst sort. no sand to be used) in the ratio 1:3 ( 1 cement and 3stone chips of 10mm gauge) including thread lining, curing, providing 25mm dia G.I.Pipe of necessary length for water outlet. 29 Tactile Paver Type of New Tek BT Yellow Colour Ceramic Tile of size 305 x 305 x 15mm for Vision Impairment Person. M-0226 30 Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from unplasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. 31 UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chamberedsections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work 32 Paving the floor with fine polished cuddapah stone slab of 50mm thick laid over Cement Mortar 1:3 (One Cement and Three Sand) 20mm thick over the existing bed of Cement Concrete 1:5:10, (One Cement, Five Sand and Ten aggregate) and pointing the joints to full depth of slabs with same mortar mixed with black oxide and the top surface rendered smooth, curing, etc., The cuddapah stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete complying with standard specification. 33 Manfacturing supplying and fixing of Stainless steel hand rails for staticase near wwet riser using 50mm ida 304l Grade SS pipe of 1.60mm thick will be provided with tubular supports made of 304l frade SS pipe of 25mm dia of 1.60mm thick welded to the railing. the supports will be grouted into the wall and provided with 93.00mm thick stainless steel circular base plate of 304 grade. The rate shall included for grounting into concrete with necessary supporting and arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges,electrical charges, etc., complete 34 UPVC Window Specification:Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work. 35 Paving the top of roof with one course of Solar Reflective ceramic tiles of size 305x305x7mm of approved quality set in cement mortar 1:3 (one cement and three sand) 12mm thick mixed with Epoxy packing conforming to ISS including curing etc., Complete complying with standard specification and as directed by the departmental officers. 36 Providing protective over the water proofing treatment provided over base concrete,RCC retaining wall, sunken slab and terrace in CM 1:4 to a minimum thickness of 12mm with etc complete. 37 Supplying and fixing P.V.C. pipe 110mm dia rain water downfall pipe as per ISI standard (I.S.4985) with door arrangements including P.V.C.Bend, shoes, grating with F.I.clamps 40mmx20mm of suitable size fixed to wooden plugs embedded in walls in cement mortar 1:3( 1 cement and 3 Crushed Stone Sand (Commercially called M-Sand) ) includin cutting holes in walls and making good thesame after fixing the plugs etc.complete.BD-667 38 Supplying and fixing of PVC Sliding Door with Roller incluing all necessary fitting atc complete. PWDM-0393 39 Flooring rendered smooth with cement at 10kg. per 10sq.m.including curing etc.,complete as directed during.BD-475 execution. 40 Supplying and fixingpaver block60mm thick of approved make at parking area, driveways below the pavers as sub base, sand filling between the pavers ad compacting the same as per directions. 41 The complete system to be designed to with stand design wind pressure of 200Kg/Sqm + Corner effect 15% of wind load, total pressure shall be 230 Kg/Sqm as minimum and confirming to IS 875 part 3 and other load parameters specified and other load parameters specified in Technical specification. Light Transmission - 20 to 65%, SHGC - 0.28 to 0.53 & U- value - 1.5 W/Sqm.k.Rate shall include the cost of aluminum anodized Uframe as end cap to protect the all exposed edges of the polycarbonate sheets / polycarbonate U connector, 1.0 mm thick aluminium exterior grade powder coated (Not less than 60 microns) flashing with suitable size as per site condition for around the roofing with approved colour and flashing shall be fixed with SS 316 grade screws with suitable spacing, the flashing shall have minimum overlap of 100 mm and the joints shall be sealed with weather silicon sealant, with nessecery EPDM gasket, adhesive tape and non staining weather sealant of Dow corning make with approved colour matching with polycarbonate sheet if required, scaffolding upto the required level with suitable system etc, complete. Rate shall exclude the cost of Base M.S frame works, which will be measured separately.Mode of Measurement: Length and breadth of the finished Horizontal Plan area will be measured for payment, irrespective of profile as per approved shop drawing. Note: Vertical cladding / flashing shall not be measured for payment. For Terrace level Roofing. 42 Supply and fixing in position of Hot rolled structural steel Members/ Sections consisting of MS joists, channels, angles, purlins, pipes, hollow tubes, runners, insert plates, etc. at all levels. Surface preparation of all MS members by Sand blasting to SA 21/2 grade and painted with anti corrosive, PU paint (metallic finish) with compatible primer to a minimum film thickness of 75 microns and 2 coats of PU paint of and total dry film thickness 225 microns Rate to including all Lifts, wastage, cost of bolts, nuts, washers, welding,flashing, electrodes and connections required for the work. No extra on this account will be paid for, and the rate to include preparation of fabrication shop drawings for owners approval. etc., as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge 43 Roofing with best quality Plain GI Sheet 0.8mm thick (22 Gauge)including cost of J bolt , bitument washer and cutting the sheet to required size if found necessary during execution etc., complete. 44 Providing and casting in situ the foundation bolt grouting with non-shrink grout (Conbextra GP-2 or equivalent)as per manufactures specifications excluding the cost of bolts and including all materials, tools , pouring at specified consistency, cleaning etc. complete as per drawings. 45 Supplying And Fixing of Rubber Moulded Grey Premium Concrete Kerb of Size450X125X300mm Using M30 Concrete. The Concrete Shall Be Moulded By Table Mount Vibrated With Polypropylene Fibers At 5% And Curing Compound. The Rate Shall Include Cost of Materials Transportation Loading Unloading Charges And All Taxes Including Necessary Earth Work Pointing With cm. 1:3 To Full Depth Curing Thread Lining Etc Complete 46 Flooring with ordinary cuddapah slabs 50mm thick jelly in Lime mortar 1:2:5 ( 1 lime, 2 Crushed Stone Sand (Commercially called MSand) and 5 broken brick jelly) including pointing with C.M.1:3 etc complete. 47 Providing & marking the border using Acrylic floor paint as per standards etc complete. 48 Supply & fixing of .weldmesh withoutframes including fixing in position in the existing framesetc., complete. The size of weldmesh will be 75 x 25mm. (ISI STD) 49 Plumbing Work : (Soil,waste,vent and Rain Water pipes)Renewing andlaying and jointingUPVC Pipe(Un-Plasticized Polyvinyl Chloride) UPVC used for residential and home applications, water pressure in residential areas do not normally exceed the maximum tolerance.(schedule-40) but excluding cost of such specials and fixing in position dismantling masonry and make the same to original conditionetc complete complying with standard specification and as directed by the departmental officers at site of work. Location: Inside Toilet & pantry: 50 75mm dia 51 110mm dia 52 Supplying and fixing of Leaf trap with kurra made out of pVC flange and grating for rain water outlets etc., complete 53 a) 75mm dia 54 b) 110mm dia 55 Supplying and fixing of 200mm wide 150mm depth 3mm (4Kg/cm2 gauge) thick square UPVD raon water cutter, suitable outlet and fittings & etc., complete. 56 Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works) 57 Supplying and fixing of SS heavy grating cover (Cockroach trap) (150mmx150mm) etc., complete 58 Supplying, installing, testing and commissioning of domestic water transfer Pumpfor flushing OHT Filling of continuous duty submersible centrifugalpumps complete with 3 phase motor. Each pump shall have TEFC1450 RPM three phase electric motor. all necessary protection and mechanical seal etc with Cabling upto Control Panel , Level controller switch for domestic tanks (Solenoid valve with all accessories for automatic operation of water filling from UG Sump to OHT) with required wiring etc complete .Vendor to submit proposed pump model with duty curve.The pump shall be suitable for auto/ manual operation. 59 Providing and fixing 100 mm sand cast Iron grating for Nahani/Floor trap 60 Renewing andlaying and jointingUPVC Pipe(Un-Plasticized Polyvinyl Chloride) UPVC used for residential and home applications, water pressure in residential areas do not normally exceed the maximum tolerance.(schedule-40) but excluding cost of such specials and fixing in position dismantling masonry and make the same to original conditionetc complete complying with standard specification and as directed by the departmental officers at site of work.Location: Internal WB & UR connection pipe 61 40mm dia 62 Supply,Laying, Testing and Commissioning of PVC Cleanout with heave duty nickel bronze gasket cover for Soil, Waste pipes inside the Toilet area and making it complete for operation. Supply of necessary accessories white cement, solvent cement, teflon tape, screws, clamps, etc for complete installation. Scope includes fixing and finishing the opening and providing PVC cleanout plug to the Soil, Waste and Vent pipe with sufficient bend arrangement, should ensure easy removal & accessing.Vendor shall directly co-ordinate with other package vendors of the project for smooth installation and handing over. The pipe and fittingsshall be ISI marked. The workmanship and technical requirements should be as per CPWD Specification. 63 75 mm dia 64 110 mm dia 65 WATER SUPPLY SYSTEM (DOMESTIC WATER SUPPLY PIPE & ACCESSORIES): Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.The Concealed work, including cutting chases and making good the walls etc. 66 20 mm nominal outer dia Pipes 67 Supplying ,fixing,testing and commissioning ofPVC pipe confirming to IS 4985 of Agricultural series - 6 kgs / sq.cm pressure rated, for underground soil, waste and ventlaid under the soil from manhole to manhole outside the building, to the required slopes, jointing withsolvent cement followed by application leak proof adhesives of FRP paste, including haunching / covering only the joints with cement concrete 1:3:6 at all the joints with and testing of joints with water column etc. complete. Location:External soil & waste pipe 68 110mm dia 69 160mm dis 70 Supplying and erecting SINTEX or approved equivalent make HDPE plastic vertical cylindrical 2000 Litre Water Storage Tank. Strickly adhering ISI Standard as per ISI Mark 12701 (Latest revision) including all taxes and freight charges within Corpn.City limit.BD-865 71 Supplying and fixing FRC cover and frame 60x60cm size including necessary masonry work with cement mortar, fixing etccomplete 72 Providing & Fixing of Signages with necessary Support as per drawing. The Rate is inclusive of MS Square frame with Powder Coating,Labour, Material, transportation etc., complete complying with standard specification. Acrylic sheet with CNC cut & LED lighting 73 Construction of Soak Pit 1.9m dia including necessary earth work excavation supplying and filling in with Crushed Stone Sand (Commercially called MSand providing and laying PCC 1:3:6 using40mm B.G.metal, and providing and laying PCC 1:2:4 using 12 to 20mm size B.G.Metal, stock brick work in C.M.1:3 for 23cm thick wall, plastering in C.M.1:3,15mm thick including making necessary drainage arrangements by providing S.W.Gully trap15x10cm with silt pit and 100mm dia S.W.pipe connection to a depth of 90cm, ,etc.,complete 74 SANITARY FIXTURES- Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm P or S trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings.such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications.(The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works) 75 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 76 Supplying and fixing in position 15mm dia two way bibcock (heavy duty) with health faucet of approved make conforming to BIS specifications and quality including cost of shellac, thread etc. complete complying with standard specification and including cutting and threading wherever necessary. Taps should be approved by the Executive engineer in-charge. 77 Supplying and fixing in position best quality and make Indian made approved colour glazed earthernware wash hand basin of size 550 x 400mm (without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia B class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass |waste coupling including fixing of wash basin using Ci Each brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the |brackets with two coat of painting over a priming coat| |of anti-corrosive paint including testing for leakages etc., complete complying with standard specification |and as directed by the departmental officers. The wash hand basin and specials should be got approved by the Executive engineer. 78 Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 79 Providing and fixing C.P. brass angle valve with wall flange for basin mixer and sink points of approved quality conforming to IS:8931.Material should be selected by engineer incharge. 80 15mm nominal bore 81 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm)of approved make and quality as per direction of Engineer-in-charge. 82 Providing and fixing unplasticised P.V.C. connection pipe with PTMTNuts, collar and bush of approved quality and colour..Material should be selected by engineer incharge. 83 15 mm nominal bore with 45 cm length 84 Supply and Fixing of 15mm CP brass single lever concealed bath and shower wall mixer with diverter, 3way shower head, spout,OH shower with adjustable type arm with wall flange with slipfit connection & hand shower with flexible pipe with bracket including all accessories. 85 Supply and Fixing of 15mm CP brass shower valve with diverter, 3way shower head, spout,OH shower with adjustable type arm with wall flange with slipfit connection with bracket including all accessories. 86 Supplying, Installing and testing of approved make horizontal type electric water heater with heating elements with necessary grip bolts and accessories etc., complete. The cappacity shall be 10 lires with suitable wattage. 87 Supplying , Installing and testing of raised toilet seat with cover for handicap toilet. 88 WATER SUPPLY SYSTEM (DOMESTIC WATER SUPPLY PIPE & ACCESSORIES)- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed pipes. 89 20 mm nominal outer dia Pipes 90 25 mm nominal outer dia Pipes 91 32 mm nominal outer dia Pipes 92 40 mm nominal outer dia Pipes 93 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge - External work. 94 40 mm nominal outer dia Pipes 95 Providing and fixing ball valve (brass) of approved quality, High or low pressure with complete as required. 96 20 mm nominal bore 97 25 mm nominal bore 98 32 mm nominal bore 99 40 mm nominal bore 100 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 101 a)50 mm nominal bore 102 b) 100 mm nominal bore 103 Supplying&fixing screwed ended gun metal horizontal / vertical nonreturn valve conforming to IS 5312 of PN 10 pressure ratingincluding rubber gasket, union, etc. complete as required. 104 a) 40 mm nominal dia 105 Supplying & fixing of brass Auto Air vent with isolation valve for cold water supply risers, suitable for working pressure not less than 10 Kg/Sq.cm. 106 a) 20 mm dia 107 Supplying and fixing of 2000 liters capacity of triple layer sintex water storage tank with float valve & required all accessories. 108 External Manhole and Accessories - Manhole chamber of following with a base concrete of by new on of a base of concrete of Plain cement concrete 1:5:10, 10cm thick over a 10cm sand cushiion & brick work in CM 1:5 for chamber wall with 20mm thick 1:3 CM plastering for walls flooring including cost of labour charges curing cost of sFRC cover slab of size O.60x0.60 including labour charges for fixing the slab inposition etc., 109 600mm x W 600mm x D 600mm 110 Supplying and fixing in position 150 x 100mm p or S stoneware gully trap A grade with Cl double gratings of size 150 x 150mm and 230 x 230mm at bottom and top respectively with necessary earth work excavation laid over a bed of brick jelly cement concrete 1:3:6 (One cement, Three sand and Six broken brick jelly) 150mm thick using 40mm size broken brick jelly including necessary brick work and plastering including dismantling masonry wherever necessarv and re-doing the damaged portions to the original conditions using cement Concrete 1:3:6 using 20mm stone jelly for fixing the gully trap and giving connections to stoneware sewer line etc., complete complving with standard specifications. [Earth work excavation, brick work, plastering shall be measured and paid separately]. The stoneware gully trap should be got approved by the Executive Engineer before use on works. 111 Electrical work-Distribution Boards - VTPN 8 WAY (Vertical TPN) MCCB INCOMER DB: Supply, fixing, testing and commissioning of the double door type VTPN 8 way MCCB DB comprising of the following :INCOMER: 125A TPN MCCB 16 KA – 1No. as incomer with ELMOUTGOING:63A TP MCB 10kA (C-Curve) – 8 Nos..as outgoings.With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be powder coated type fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc. 112 LDB - 4 WAY (7 segment) MCB INCOMER DB: Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 8way MCB DB comprising of the following :INCOMER: 40A 4P MCB 10kA with all necessary connected accessories – 1No.25A DPMCB WITH 25A DPRCBO 30 mA – 3 Nos. as individual phase incomersOUTGOING:Each 25A DP RCBO outgoing consist of 4nos.61620 A 10KASP MCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate.With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be powder coated type fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc. 113 PDB - 4 WAY (7 segment) MCB INCOMER DB: Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 8way MCB DB comprising of the following :INCOMER: 63A TPN MCB 10kA with all necessary connected accessories – 1No.32A DP RCBO 100 mA – 3 Nos. as individual phase incomersOUTGOING:Each 40A DP ELCB 100MAWITH 40A DP MCB outgoing consist of 4nos.61620 A 10KASP MCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate.With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be powder coated type fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc. 114 Cable and Termination - For all items in section-D, the rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the sameSupply and Laying of following size PVC/XLPE (FR-LS) insulated outer sheathed (1100 V grade) copper/aluminium armored & un armored conductor cable partly laid incable tray and partly laid in wall/ ceiling with suitable individual clamps at every 1 mtr interval . Cable tray will be measured and paid separately. Cable Tags to be provided at every 50mtr interval and at either side of the bends.Only for Lighting cables cable tie will be permitted other cables clamps to be provided 115 3.5 Core 95 Sq.mm XLPE Aluminium armoured Cable 116 4 Core 16 Sq.mm XLPE Aluminium armoured Cable 117 4 Core 6 Sq.mm XLPE Copper armoured Cable 118 3 Core 4 Sq.mm PVC Copper armoured Cable 119 Supply, Fixing of Termination kit (Glands & lugs) of the following size cables with suitable double compression glands with suitable crimping socket. The rate shall be inclusive of Gland Earthing Plate Prefabricated as per Gland Size with provision for connecting Cu.SWG and Cable Tags should be engraved type for all I/C,O.G& lighting Circuits (copper sockets for copper cables and Alu. Sockets for alum. Cable) 120 3.5 Core 95 Sq.mm XLPE Aluminium armoured Cable 121 4 Core 16 Sq.mm XLPE Aluminium armoured Cable 122 4 Core 6 Sq.mm XLPE Copper armoured Cable 123 3 Core 4 Sq.mm PVC Copper armoured Cable 124 MCB, Isolators,MCCB- Supply,installation,testing andcommissioningofthe followingMCCBs / MCBs / ISOLATORs / STARTERs of type-II coordination etc.in manufacturers sheet steel enclosures, IP 20 Protection, fixed on the concealed wall including all interconnections and accessories. Supply, Installation, testing and commissioning of of cubicle type floor mounting/wall mounting isolator panel. The rate shall be inclusive of suitable MS angle ion standand suitable size enclosure with adopter boxes for cable termiantion,spread bar,etc. 125 25A DP MCB along with moulded front plate in GI anodized box 126 63A TPN Isolator(MCCB type)with enclosure for ups /VRF 127 63A TPN RCCB 300MA IP66with metal power coated steel enclosureforVRF 128 Wiring -Circute Point Wiring - The rates for all point wiring items shall also includesupplying and fixing of the Conduits,conduitspecials, bushes and other fittings,Approved GI saddles and grouting thesame for exposed conduit work,2 mm thick Outlet boxes and junction box,All fixing accessories such as clips, brass screws etc,Allwork & materials necessary for wiring a point circuit of anylengthfromtheFinal DistributionBoardto connectorviaswitch and shall include thecircuitwiring also except where identified. 129 Primary Light / Fan Point Wiring: Supply, wiring, connecting& commissioning of 3Runs1.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistrandedHR-FRLSH-LFcopper wires in 1.8mm thick MS conduits fixed on ceiling partly and1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition including supplying and fixing of modular 6A One way switch along with moulded front plate in GI anodised manufacturers mounting box-Flat switches with indication fixed flush with the wall complete with all accessories including 3 plate ceiling rose.NOTE: Above false ceiling when it is open wiring it should be of MS conduit 130 Secondary Light Points: The secondary light points will have to be wired from the primary light point as mentioned above. 131 Lighting Circuit Mains: Supply and laying of 3 Runs2.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistrandedHR-FRLSH-LFcopper wires in 1.8mm thick MS conduits fixed on ceiling partly and1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition., from LDB to Lighting Switch Boards and MCB to First Light Point. 132 TWO-WAY POINTSSITC of Concealed Point wiring (from Switch board) including Concealed Circuit Wiring (from DB to switch board) for two way like staircase points after cutting grooves on wall/ RCC, neatly filling the grooves with cement mortar,making good thereof, etc. using 3 x 1.5 Sq. mm.heavy duty PVC insulated copper conductor stranded cable (1 for earthing),2 Nos. Modular 2-way switch complete with non metallic inner & outer plates, suitable metal boxes, etc,IS marked(IS 9537 Part-3) suitably sized heavy duty rigid concealedMS conduits (20mm min), Saddles, junction boxes, bends, other accessories, ceiling roses, etc. 133 Ceiling Fan Points: Supply,installation,testingand commissioning of ceiling fan points same asPrimary Light Point Wiringbut for ceiling fan points including supplying and fixing concealed type fan hook box and supply and fixing of electronic type 300W fan step regulator with moulded front plate in GI anodised manufacturers mounting box fixed flush with the wall complete with all accessories as required as per the site conditions. 134 Emergency Lighting Circuits: Supply and laying of 3 Runs1.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistranded FRLS copper wires in 1.8mm thick MSconduits fixed on ceiling partly and1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition.,from ELDB to Emergency Light fittings. 135 Scokets- Supply, Installation, testing and commissioning of 1 no 6A Universal switched socketand withmoulded frontplate, GIanodised enclosure, and mounting box in the wall(concealed/open)andother associated accessories including chasing embeddingrough plastering as required as per the site conditions forpower points. 136 Supply, Installation, testing and commissioning of 1 no 6/16A universal switched socket and withmoulded frontplate GIanodised enclosure in the wall/floor(concealed/open andother associated accessories including chasing embeddingrough plastering as required as per the site conditionsforpower points. 137 Supply, Erection,Testing and commissioning of 32A 3Phase Metal clad plug and socket with 32 A TP MCB as control with enclosure,Plug top cover and connected accessories . Legrand cat no 056614 138 Supply & Laying of 2R 4 sq.mm and 1R 2.5 Sq.mm. PVC insulated FRLS multistranded cu wires 20mm dia 2 mm thick MS conduit with all accessories as reqd. (From DB to 6/16A Power Sockets / 20A Metal clad plug & sockets.). 139 Supply & Laying of 2R 2.5sqmm and 1R 2.5 Sq.mm. PVC insulated FRLS multistranded cu wires in the 20mm dia 2mm thickMS conduits with all accessories as reqd. (From DB to 6A Switch & Sockets) 140 Cable Trays - Supply and erection of following size 2mm thickLadder type,Pregalvanized, cable trays and cable tray of rolledGI Sheet, supports out sections, pipes, plates, etc. including welding, anchor bolts, threaded down rods(for 300 mm trays only), supply of necessary anchor bolts and grouting etc. including breaking walls, floors, etc. for structures as required including supply of all GI hardware materials, all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-charge.The rate shall include supply & fixing of MS Grip bolts in columns/beams/walls/ceiling etc.as required & including drilling also. Rod supports shall be of galvanized full threaded rods of sizes 8,10 & 12mm dia for fixing to anchor fastener, anchor bolts.The length of the full threaded rods for the purposes of quoting shall be 1200 mm & includes nuts & washers and supports shall be at a min.distance of 1Mtr.The rate will include all required bends, tees, vertical up & downs, radius bends and other applicable accessories shall be factory fabricated, complete & as required. The rate shall inclusive of necessary theaded rods,nuts & bolts, making clamp in the Z perlin/Truss, cable tray clamps etc,(8 mm threaded rod shall be providedat every alternative purlin appx. 2 mtr length) 141 300 x 50mm x2mm Ladder type cable trays 142 150 x 50mm x2mmLadder type cable trays 143 Light Fitting : supply erection and testing and commissioning of Recess mounted type - LT PUPIL 18W SURFACE or eqvt 144 Supply and fixing of single box type 418W LED Tubelight fitting complete with electronic ballast with TW round blocks on wall or ceiling with PVC unsheathed Copper leads from terminals to the fitting 145 supply erection and testing and commissioning of Recess mounted type - LT LUXTRUST 30W 146 Supply and fixing of 1200mm (48) sweep AC ceiling fan complete with stepped electronic 300W regulator with l sq.mm. PVC copper cable and Fan clamp with side plate and 45cm cross arm 147 Light Fitting - Supply, Installation, testing and commissioning of earth plate of size 600 x 600 x 3mmcopper plate earth electrode at a depth 3000 mm in an earth pit of 450 x 450 x 350mm filled with salt and charcoal mixed with sand in alternate layers of 150mm each up to a height of 3000mm from bottom. Two copper flats of size 25 x 3 mm shall be braced to this copper plate throughout the overlapping length with the copper plate and brought to the surface of the earth pit. This plate shall have provision for connecting wires or flats as the case may be. A suitable size of 25/ 38mm dia GI pipe shall be provided up to bottom of the earth pit. This GI pipe shall have provision for watering through a funnel. A masonrystructure of wall thickness of not less than 230mm shall be constructed to a depth of 450mm and heavy duty SFRC cover shall be used to cover the pit. 148 25 x 3mm copper flats for earthing 149 8 SWG bare Copper conductor for fencing earthing 150 10 SWG copper wire 151 Earthing - Supply and Installation of Danger Boards 415 V (Stove enameled) as per EB standards. 152 Supply and laying of 12mm thick 1000mm wide chequered rubber mat with ISI mark suitable for 440V installation . 153 Shock Treatment Chart in 2 Language (Local Language and English)

Key Value

Document Fees
Refer document
EMD
INR 75000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail