Tender For Misc Repair To External Electric Supply At Ad Patti Hussainiwala And Harike And Solar Plant Under Age Em Of Ge (West) Ferozepur Cantt; 1 Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting out in hard/dense soil complete all as specified and directed. 2 Returning, filling, including spreading, levelling, watering and well ramming in layrs not exceeding 25cm in soft/loose soil complete all as specified and directed. 3 Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. 4 Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable aftger laying complete all as specified and directed. Note: Punned thickness shall be measured. 5 M&L sub class B bricks locally availableof size 22cm x 11.5cmx 7.5cm laid dry width wise across the line of cable in trenches for protection of underground cable complete all as specified and directed. 6 Supply and spreadinng coarse gradedaggregate of nominal size 20mm in above outdoor LT sub stns ccomplete all as specified and directed. 7 M&L in replacement of 40 mm bore steel for tubing, light grade, ISI marked for protection of cable including necessary joint and taking down complete all as specified and directed. 8 M&L in replacement of pin type porcelain, vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers &one galvanized iron nuts, 100 mm height, 65 mm dia for1100 volts grade after dismantling & taking out old unserviceable and complete all as specified and directed. 9 M&Lin replacement of cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape of size as dircted including applying of two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. 10 M&L in replacement ofMCCB adjustable thermal & fixed magnetic setting type 160 Amps, 4 pole of breaking capacity 25 to 36 KA, 415 Volt after and including taking down of unserviceable one complete all as specified and directed. 11 M&L in replacement MCCB adjustable thermal & fixed magnetic setting type 400 Amps, 4 pole of breaking capacity 25 to 36 KA, 415 Volt after and including taking down of unserviceable one complete all as specified and directed. 12 M&L in replacement MCCB adjustable thermal & fixed magnetic setting type 250 Amps, 4 pole of breaking capacity 25 to 36 KA, 415 Volt after and including taking down of unserviceable one complete all as specified and directed. 13 M&L in replacement MCCB adjustable thermal & fixed magnetic setting type 100 Amps, 4 pole of breaking capacity 25 KA, 415 Volt after and including taking down of unserviceable one complete all as specified and directed. 14 M&L MCCB in replacement of adjustable thermal & fixed magnetic setting type 125 Amps, 4 pole of breaking capacity 25 KA, 415 Volt after and including taking down of unserviceable one complete all as specified and directed. 15 M&L MCCB in replacement of adjustable thermal & fixed magnetic setting type 63 Amps, 4 pole of breaking capacity 25 KA, 415 Volt after and including taking down of unserviceable one complete all as specified and directed. 16 S&F in replacement ofChangeover Four pole 100 Amps capacity with SS Enclosure handle with door interlock kitfixed on wooden plank complete all as specified and directed. 17 S&F in replacement ofChangeover Four pole 63 Amps capacity with SS Enclosure handle with door interlock kitfixed on wooden plank complete all as specified and directed. 18 S&F in replacement of 1100 Volts, 16 Sqmm grade heavy duty cable PVC insulated aluminium strandad conductor, served with inner sheathing of PVC tape and overall PVC sheathed intwin core cable circular/flat complete all as specified and directed. 19 S&F in replacement of 1100 Volts, 10 Sqmm grade heavy duty cable PVC insulated aluminium strandad conductor, served with inner sheathing of PVC tape and overall PVC sheathed intwin core cable circular/flat complete all as specified and directed. 20 S&F in replacement of1100 Volts, 6 Sqmm grade heavy duty cable PVC insulated aluminium strandad conductor, served with inner sheathing of PVC tape and overall PVC sheathed intwin core cable circular/flat cpmlete all as specified and directed. 21 Supply, laying,testing in replacement of underground cable XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 95 sqmm 3.5 core complete all as specified and directed. 22 Supply, laying, testing in replacement of underground cable XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor 1100 Volts grade cross section area 50 sqmm 3.5 core complete all as specified and directed. 23 Supply, laying, testing in replacement of underground cable XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 70 sqmm 3.5 core complete all as specified and directed. 24 Supply, laying, testing in replacement of underground cable XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 16 sqmm 4 core complete all as specified and directed. 25 Supply, laying, testing in replacement of underground cable XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 10 sqmm 4 core complete all as specified and directed.Note: (for Ser item No. 18 to 25):-(i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid for separately under relevant items. 26 M&L meggering of cableincluding cable jointing kit of 1.1 KV (LT) grade for Heat-shrinkabIe straight through after disconnecting from LT Pole/panel as directed,and finding out fault including required earth work, cutting of cable andpreparation for jointing of defective portion of cable complete with jointing material and accessories suitable for PVC/XLPE armored aluminum stranded conductor cable of size 50/70/95 Sqmm3.5 core complete all as specified and directed 27 M&L meggering of cableincluding cable jointing kit of 1.1 KV (LT) grade for Heat-shrinkabIe straight through after disconnecting from LT Pole/panel as directed,and finding out fault including required earth work, cutting of cable andpreparation for jointing of defective portion of cable complete with jointing material and accessories suitable for PVC/XLPE armored aluminum stranded conductor cable of size 25/16/10 Sqmm4 core complete all as specified and directed 28 M&L repair of outdoor type LT Panel/Feeder pillarby repair offront & rear doors/ shutters, made out of MS/CRCA Sheet 3.15 mm thickness with necessary fabrication work likereplacement ofhinges, locking knob Bending, welding and painting with two coats of synthetic enamel paints over a coat of red oxide matching with existing panel colour as required at site complete all as specified anddirected. 29 Supply & FixingAmmeter of Minimum ranging upto 0-400 Amps alongwith Suitable CTs and Selector Switch as per existing item complete all as specified and directed. 30 Supply & FixingVoltmeter of Minimum ranging upto 0-500 Volt alongwith Suitable PTs and Selector Switch as per existing item complete all as specified and directed. 31 Supply, installation, testing and commissioning in replacement of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, suitable for AC, 3 phase 4 wire, 50 cycles, 415 Volts,Front & Rear openable double door with locking arrangement. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.3m x 1.0 m x 0.45 m ) with Synthetic enemal Paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm , thimbles including cable entry glands , all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr hight from GL& 1/2 mtr for Below GL in PCC (1:3:6) type C-2 using 40 mm stone aggregatescomprising of following:-(i) Panel having common aluminium bus bar of capacity 400 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCBs,including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable sizeicluding removal of existing panel and make necessary connections as per existing. 32 (ii) Incoming:-(a) MCCB Adjustable type thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 250 Amp 4 Pole ICU = ICS = 36 KA with overload variation 40-100%- 01 Nos.(Incoming)(iii) Outgoing:-(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 160 Amp 4 Pole ICU = ICS = 16 KA with overload variation 40-100%- 02 Nos.(outgoing)(c)Same as above but of Capacity 100 Amps, 4 Pole 16 KA -01 Nos.(outgoing)(d) Same as above but of Capacity 63 Amps, 4 Pole 16 KA -01 Nos.(outgoing)(e)MCBSPN 32 Amps SPN 10 KA ,240 V(out going) -03 Nos(iv) Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 Nos(v) Ammeter 0 - 400 Amps digital type square shape 96mm flush mounted with selector switch and CTs 400/5 A - 1 Nos.(vi) Indicator lamp RYB :01 Set. with CT Coil complete. 33 Supply, installation, testing and commissioning in replacement of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, suitable for AC, 3 phase 4 wire, 50 cycles, 415 Volts,Front & Rear openable double door with locking arrangement. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.2m x 1.0 m x 0.45 m ) with Synthetic enemal Paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm , thimbles including cable entry glands , all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr hight from GL& 1/2 mtr for Below GL in PCC (1:3:6) type C-2 using 40 mm stone aggregatescomprising of following:-(i) Panel having common aluminium bus bar of capacity 320 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCBs,including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable sizeicluding removal of existing panel and make necessary connections as per existing. 34 (ii) Incoming:-(a) MCCB Adjustable type thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 160Amp 4 Pole ICU = ICS = 16 to 25 KA (iii) Outgoing:-(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 Amp 4 Pole ICU = ICS = 16 KA- 03 Nos.(outgoing)(b)MCBSPN 32 Amps SPN 10 KA ,240 V(out going) -04 Nos(iv) Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 Nos(v) Ammeter 0 - 400 Amps digital type square shape 96mm flush mounted with selector switch and CTs 400/5 A - 1 Nos.(vi) Indicator lamp RYB :01 Set. with CT Coil complete. 35 Supply, installation, testing and commissioning factory made, LT bus bar panel board cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA sheet(Min size 0.4 m x 0.4 m x 0.35 m )with Synthetic enemal Paint both side. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr hight from GL& 1/2 mtr for Below GL in PCC 1:3:6 type C-2 (using 40 mm graded stone aggregates).The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with and comprising of the following:- (i) Epoxy insulated common aluminium bus bar of capacity 200 Amp TPN each with Color Coding, including aluminium lugs to connect the cable. 36 M&L in replacement ofXLPE Insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 Volts, grade cross sectional area 95 Sqmm 3 Core including taking out old cable complete all as specified and directed.Note: Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid for separately under relevant item. 37 S&F in replacement of cable jointing kit for 11000 Volt (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm 3 Core complete all as specified and directed. 38 S&F in replacement of cable jointing kit for 11000 Volt (Earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed. 39 M&L earthing complete with galvanised steel plate electrodes of size 600mmx600mm and 6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised 4mm diameter earth lead by meansof nuts bolts check nuts & washers of GIwith earth strip protected by galvanised iron pipe 15mm bore (Medium grade) for poles/lightening arrestors/GO Switch including connecting to LT overhead linesallas directed including concrete pit with PCC (1:3:6) type CI, precast RCC(1:2:4) type B-1 cover slab of size 54cmx54cmx50cm thick reinforced with 8mm hard drawn steel wire fabricated weighting exc 4 Kg/sqm with one handl e for lifting made out of 8 mm diameter MS bar finnel wiere mesh 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke andsalt in alternate layers including necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completeion including taking down complete as specified and as directed. 40 Disconnecting and taking down repairable LED type street light fitting of any type and capacity and make from existing 9 meter/11 meter pole for checking to find out the defects cleaning the glass and prefix cover, repair/replacement of spare parts including necessary wiring etc for making the fitting in serviceable condition and refixing in original position, testing etc complete all as specifiedand directed. Note: Spare parts will be measured and paid for separtely. 41 Supply only LED driver 240Volt 50Hz for 40 to 48 watt LED fittings. 42 Supply only LED driver 240Volt 50Hz for 60 to 90 watt LED fittings. 43 S&F in replacement ofstreet light pole cable junction box IP-65 with metnic knockoutsforcable entryand the box made out of thermal plastic material suitable for 16/25 sqmm underground cable including clamps bolts, nutsduly painted and MCB SP 6Amp etc complete all as specified & directed 44 M&L painting to steel tubular pole with existing paint and including cross armsupto 11m long (except planting depth /PCC coping) with including one coat aluminum paintincluding preparation of old painted surface & numbering of poles completeall as specified and directed. 45 M&L painting of LT PCC pole upto 1.5 m height from PCC, of synthetic enamelpaint over a coat of cementprimer with black and white stripswith aluminum paint on pole & numbering of poles complete all as specified and directed. 46 S&F GI bracket for street light fitting bend to shape made out of GI pipe light grade 40mm bore upto1.2 mtr longetc complete with MS clamps duly painted with two coat of aluminum paint with nuts/bolts/washers for fixing arrangement to pole /wall complete all as specified and directed. 47 S&F GI bracket for street light fitting bend to shape made out of GI pipe light grade 20 mm bore upto1.2 mtr longetc complete with MS clamps duly painted with two coat of aluminum paint with nuts/bolts/washers for fixing arrangement to pole/wall complete all as specified and directed. 48 M&L in replacement ofwiring for circuit/street light connectionwith FRLS PVC insulated Copper conductor sigle core cable in surface/recessed in PVC conduit or Pole circuit of suitable size 2x2.5 sqmm+ 1x1.5 sqmm earth wire as continous earthing complete all as specified and directed. Note: Two run 2.5 Sqmm of cable shall be measured as single run. 49 Taking down of the UNSV/ defective transformers of capacity Upto 75 KVA(out door/Indoor type) from the existing site located in cantt area after disconnecting the in/out connection,transporting the transformers to workshop/factory for repairs,testing and transporting the same back after repairs and installing, hoisting of transformers on two/four pole structureat height not less than 3 metre, making all electric connections with HT/LT side jumpers and leads including earth connections etc and testing, complete all as specified and directed. Notes for item No 47:-(i) Oil container for collecting old transformer oil will be arranged by the contractor.(ii) The T&P such as chainpulley, crane for loading, unloading, transporting and for installing and hoisting shall also be arranged by the contractor.(a) Fixing LT coil DPC copper wire/strip of existing size(gauge) grade and in weight complete with insulating material for transformerscomplete all as specified (including the following). (b) Replacement of all LT brass spindles complete , nuts, bolts, washers for transformers of Suitable Capacity complete all as specified.(c) Silica gel breathers assembly filled with silica gel (01 Nos) complete for transformers of capacitycomplete all as specified. 50 M&L opening the top of defective transformer of any make and capacity Upto 75 KVA removing gasket and lifting up the core assembly carefully to check the condition of transformer for repairs, dismantling core lamination to the extent required for taking outdefective/ unserviceable coil for check after disconnecting all connections and re-assemblingof core lamination to original position after positioning of existing serviceable coil alongwith new coils carefully to check the condition of transformer to ascertain the repairs/replacement of U/S parts including cleaning the tank, removing sludge, dirtcleaning the coils of limbs, re-fixing the core assembly and reassembling of transformer after repairs including zinc chromate paint inside , replacement of nuts bolts with washers thimbles etc and connections with aluminium strip and including welding, denting etc and testing the transformer at factory/workshopto the entire satisfaction of Engineer-in-Charge complete all as directed and as specified.(including the following )(a) Fixing LT coil DPC copper wire/strip and HV Side Coil of existing size(gauge) grade and in weight complete with insulating material for transformerscomplete all as specified. (b) Replacement of all LT brass spindles complete , nuts, bolts, washers for transformers of Suitable Capacity complete all as specified.(c) Silica gel breathers assembly filled with silica gel (01 Nos) complete for transformers of capacitycomplete all as specified.Note for Item No 48(a) The cost of new coilsto be replaced shall deemed included in the quoted rate by contractor.(b) Transformer Oil Dehydration and Topping up shall be measure and paid for seperately after repair of Transformers. 51 S&F in replacement of LT brass spindles, nuts, bolts, washers for transformers of capacvity 75 KVA to 100 KVA complete all as specified and directed. 52 S&F in replacement of LT bushing porcelain capacity 75 KVA to 100 KVA complete with gasket set complete all as specified and directed. 53 S&F in replacement top cover gasket set of 8 mm thicknes ISI marked complete all as specified and directed. 54 M&L opening, draining of oil ,stoppage of leakage ,change of gasket set complete HV/LV rods at site as required and refilling of transformer oil of capacity 75 KVA complete all as specified and directed. 55 S&Fin replacement of silica gel breathers assembly filled with silica gel complete for transformers of capacity Upto 100 KVA complete all as specified and directed. 56 S&F in replacement of temperature gauge 0 to 300 degree centgrade for transformers of capacity upto 75 KVA complete all as specified and directed. 57 Supply and pouring/ top upof new Transformer oil for Distribution Transformer Oil (as per IS 335) (EHV) of dielectric strenght min 45 KV in company sealed packed drum complete all as specified and directed. Makes :-Volvoline , HPCL, MAK,Gulf ,Servo or equivalent in approved makes 58 M&L cleaning sprinkled transformer oil, grease and all other foreign materials from external surfaces of transformers of capacity 75 KVA to 100KVA and preparing the surface to receive paint and applying one coat of synthetic enamel paint (spray painting) including writing MES number and SM number with white paint over black base in letters not less than 10 cms in height complete all as specified and asdirected.Note :- Paintingshall be carried out at site. 59 M&L removing old paint by paint removers and painting to existing outer & inner surcface of LT Control Panel of any size by using spray gunwith one coat of red oxide and two coat of synthetic enamel paints as per colour code as mentioned below of, complete all as specified and directed.(i) LT Control Panel (Outer & Inner Surface) - Dark GreyMakes of Paint:- Burger/Asian/Nerolac of first quality or equivalent in approved makes 60 Carrying out servicing/maint of 30 KVA DG set and cleaning including B check as per manufacturers manualthrough authorised dealer of DG set manufacturer of existing DG Make and testing of DG set complete all as specified and directed.Note:- All material/spares parts required for carrying out above maintenance/servicing shall be measured and paid separately as Supply only items as mentioned below and shall be of as per make of DG set and labour element required for replacing the spares parts including replacement of minor spare parts which are essential for carrying out servicing/maintenance of DG sets shall deemed to be included in the unit rate quoted by the tenderer. 61 Carrying out servicing/maint of 62.5 KVA DG set and cleaning including B check as per manufacturers manualthrough authorised dealer of DG set manufacturer of existing DG Make and testing of DG set complete all as specified and directed.Note:- All material/spares parts required for carrying out above maintenance/servicing shall be measured and paid separately as Supply only items as mentioned below and shall be of as per make of DG set and labour element required for replacing the spares parts including replacement of minor spare parts which are essential for carrying out servicing/maintenance of DG sets shall deemed to be included in the unit rate quoted by the tenderer 62 Supply only lubrication oil SAE-40 ( 15 W- 40 grade) of make: Valvoline or HP Milcy Super 20W 40H, complete all as specified and directed.Makes: HP/Servo/Gulf or equivalent in approved makes 63 Supply and filling of inhibitor corrosion (Coolant) suitable for radiators of 30 KVA capacity DG set complete all as specified and directed. 64 Supply only Lub oil filter complete set complete all as specified and directed. Makes: Kirloskar/ Micco/Bosch or equivalent in approved makes 65 Supply only Diesel filter complete set complete all as specified and directed. Makes: Kirloskar/ Micco/Bosch or equivalent in approved makes 66 Supply onlyAir Filter as per sample complete all as specified and directed. 67 Supply only Hose pipe & Flexible pipe complete set complete all as specified and directed. 68 Supply onlyFan belt for water pump complete all as specified and directed. 69 Supply onlyFan belt for alternator dynamo complete all as specified and directed. 70 Supply only lead acid battery capacity of 90 AH, 12 volts for DG sets installed on pump house complete all as specified and directed.Makes:- Exide Express/Amron/Luminous or equivalent in approved makes 71 S&F replacement of Battery Charger for Lead acid & Tubular &VRLA-SMF for Battery upto 7 AH to 120 AH, 12 Volts, single Phase AC supply 230V, 50 Hz including all type indicators, showing charging complete all as specified and directed. Makes: Luminous/ Microtek or equivalent in approved makes 72 S&F in replacement of LED security light fitting 45 Watt 230 Volt AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Makes:- Cropmton/Havells/Bajaj/Philips or equivalent in approved makes 73 S&F in replacement of LED security light fitting 45 Watt 230 Volt AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Makes:- Cropmton/Havells/Bajaj/Philips or equivalent in approved makes 74 S&F of high brightness IP 65 LED Strips of color Saffron, White & Green as per requirment with uniformity of light required to perfect outdoor application including thermal management in multiple optics complete with IP 65/66 protection complete complete all as specified and directed.Makes:- Cropmton/Havells/Bajaj/Philips or equivalent in approved makes 75 S&F in replacement of automatic street light switchfor automatic swithcing of street light/high mast light (timer switch)for Three Phase Loadlight.The Digital timer 24 hrs alongwith suitable power contractor as per IEC - 60947-4-1 , including incoming & outgoing MCBs,SMC Encloser and support terminal andenclosed in pole/wall mounted factory made PVC enclosure made out of rust proof , shock & termite proof and FRLS gradeconfirming to IP 54 of capacity 6 KW, Three phase, Contactor rating 32/TP and MCB rating 40Amp TPN, having Facility of manual operation. Makes:- HAVELLS (model - IHXTS03060 or Techno-commercially equivalent in approved makes) 76 Pump House/Electrical Installation Cleaning /Site clearence by cutting and removing shrubs, vegetation , grass , bush , weed , trees and saplings of any height up to the ground clearence.around water supply installation complete all as specified and directed.Notes:- (i) The rates quoted includes stacking of useful material and dispose off rubbish / useless material up to a distance of 50 mtr out side the periphery of the installation.(ii) Pump house area include the complete OHT area, pump house area and connected path way between pump house and OHT. 77 M&L cement concreted 1:4:8, type D-2 (using 40mm graded stone aggregate) as in foundation of poles including necessary form work, fair finished to exposed surfaces without using extra cement wherever required complete all as specified and directed. 78 M&L cement concreted 1:3:6, type C-2 (using 40mm graded stone aggregate) as in foundation of stay assembly/feeder pillar/LT panel etc including necessary form work, fair finished surfaces without using extra cement complete all as specified and directed. 79 M&L cement concreted 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in foundation of electric poles/struts/ etc including necessary form work, fair finished surfaces without using extra cement complete all as specified and directed. 80 S&F LT Pre-stressed concrete pole 9.0 metres long of cross section 102 mm x 152 mm at top and 102 mm x 289 mm at bottom class 10 complying with requirementof IS 1678-1978 incl painting of poles with two coats of synthetic enamel paint/over a coat of primer in black and white strips upto 1.5 mtrheight from top of PCCcomplete all as specified and directed.Note:- PCC and earth work shall be measured and paid for separately 81 Dehydration/ filtration of transformer oil of existing transformers (outddor/ indoor, step down) at site by means of oil dehydration machine having arrangement for heating to remove the moisture silt/ sludge and wastage removing arrangement etc to make the oil fit for use in accordance with IS-1886 to achieve minimum dielectric strength of 45 KV by continuous process of dehydration complete including testing complete all as specified and directed.Note: Testing machine shall be arranged by Contractor and charges for the same shall deemed inclusive in quoted rate. 82 M&L Air break gang operated switch, triple pole, mechanically operated, with contacts of ferrous knife and spring loaded moving contact of copper, vertically mounted,(12 insulator type) mounted on insulator and steel frame with operating mechanism in accordance with IS-9921 including 25mm bore medium grade GI pipe to worked from ground level for current rating up to 200 Amps 11000 V with locking mechanism, mild steel clamp, nuts, bolts, washers, operating handle with in both OFF and ON position of required size including two coats of aluminum paint over a coat of red oxide complete all as specified and directed. 83 M&L lightening arrestor expulsion type for outdoor suitable for 11 KV high tension line complete with all fittings with discharge capacity 65 Kilo Amperes, including bracket clamps, nuts, bolts & washers and connection to earth wire & SWG GI wire of 4mm size complete all as specified and directed.Makes: Pactil/Atlas/ Southem insulator/Jaipuria or equivalent in approved makes 84 Shifting of transformer to a distance from AGE E/M West to AD Patti & Harike, including disconneting and necessary connection and testing after shifting complete all as specified and directed. 85 Taking out Old U/S rusted/Broken Galvanised iron water main GI pipeof dia 80mm (including all fittings) cleaning the pipe and removing to store for reuse of serviceable portion if any complete all as specified and directed.Note :- Excavation & Earth Work shall be measured and paid for seperately under relevant items. 86 All as per Srl Item No 83 here-in-before but of bore of pipe 50 mm. 87 All as per Srl Item No 83 here-in-before but of bore of pipe 40 mm. 88 All as per Srl Item No 83 here-in-before but of bore of pipe 20 mm. 89 Supply and laying / fixing galvanised iron pipe, medium grade GI pipe of dia 80mm with and including allfittings and testing, complete all as specified and directed.Note:- Excavation & Earth Work shall be measured and paid forseperately under relevant items of this schedule. 90 All as per Srl Item No 87 here-in-before but of bore of pipe 50 mm. 91 All as per Srl Item No 87 here-in-before but of bore of pipe 40 mm. 92 All as per Srl Item No 87 here-in-before but of bore of pipe 20 mm. 93 Taking out old unserviceable sluice valve/Non return valveany type any size complete all as specified and directed. 94 Supply and fixing sluice valve suitable for 100 mm dia pipe ISI marked flanged type,classPN 1.6 with Stainless steel spindle, necessary bolts & nuts of suitable size with and including rubber gasket for flanged jointsand testing complete offollowing sizescomplete all as specified and directed. 95 All as per Srl Item No 92 here-in-before but of bore of pipe 80 mm. 96 Taking out old unserviceable stop valve/ gate valve any type any size complete all as specified and directed. 97 Supplyand fixing gun metal globe/gate valve suitable for 50 mm dia pipe ISI marked with and including jointing materials complete all as specified and directed. 98 Supplyand fixing gun metal globe/gate valve suitable for 25mm dia pipe ISI marked with and including jointing materials complete all as specified and directed. 99 Supplyand fixing gun metal globe/gate valve suitable for 20mm dia pipe ISI marked with and including jointing materials complete all as specified and directed. 100 Cleaning the Over Head Tank cap 10000 gallons (twin or single chamber) by draining the complete water and brushing the surfaces with iron brush and removing the complete mud/silt and getting washed the complete inner surfaces of the tank and writing date of cleaning the tank complete all as specified and directed.Note:- The cost on account ofhiring all type of T&P required for cleaning deemed to be included in the quoted rate. 101 M&L disconnecting, dismantling of solar water heating system including all water and electric connectionof capacity 500 litres per day and refixing the same in existing position after the following repairs and testingcomplete:-(a) Replacement of the worn out/missing nutsbolts , washers, unions, sockets flanges and screwetc complete. (b) Repair of collector fins including required welding works etc complete.(c) Testing on completion after Repair work and making the Solar Water Heater functional in each aspects.Note:- The Spare parts such as Solar energy collector panel, toughened glass, rubber gasket, hose pipe, insulation for hot water pipe, Assembly ,heating element, thermostat, Water Storage tank, gate valve/float valve, MS Clamp shall be measured & paid forseparately under respective items. 102 Supply only in replacement of complete one solarenergy collector panel (FPC) made of aluminium body with toughened glass complete with copper fins including all accessories capable to heat 100 Litre water per day suitable to be fitted for 500 LPD, 300 LPD & 100 LPD Solar water heating system ccomplete all as specified and directed.Makes:-Tata BP Solar/Sun Stellar/Inter Solar/RES or equivalent in approved makes. Note: 1 Solar FPC collector can heat 100LPD water. 103 Fixing in repair of existing copper strip 25mm x 3.15 mmwith saddles and fixingsscrews etcfor roof conductors and down conductors above groundcomplete all as specified and directed 104 M&L cooper strip 25mm x 3.15 mmwith saddles and fixingsscrews etcfor roof conductors and down conductors above groundcomplete all as specified and directed 105 M&L Air termination,Single pointed Copper rod 12mm dia and 300 mm long with base plate welded at bottom of termination rod 10 cm long fabricated out of 25mm x 3 mm thick flat iron along with 9 mm dia fixing fasteners (wooden block) complete all as specified and directed. 106 Fixing in repair of air termination,single pointed copper rod 12mm dia and 300 mm long with base plate welded at bottom of termination rod 10 cm long fabricated out of 25mm x 3 mm thick flat iron along with 9 mm dia fixing fasteners (wooden block) complete all as specified and directed 107 M&L test point terminal block made out of gun metal or phosphorus bronze size 75mmx75mmx25mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw complete all as specified and directed. 108 Fixing in repairtest point terminal block made out of gun metal or phosphorus bronze size 75mmx75x25mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw complete all as specified and directed. 109 M&L Earthing complete withcopper plate 60cm×60cm and 3.15mm thick electrode and thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected to 20×3mm copper strip earthing lead by means of bolts, nuts,check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre both directioncharcoal or coke and salt in alternative layers,necessary excavation & earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing completeall as specified and as directed.