Tender For Addtn/Altn To Bldg No P-211 And Certain Mw At Chafb; 1 COMMON ITEMS APPLICABLE FOR JOB A & JOB B & C 2 Surface excavation not exc 30 cm deep and averaging 15cm deep and getting out any type of soil including cutting of trunk portion protruding over ground, digging out roots, filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material to a distance n exc. 50 m and clearing site complete all as specified and as directed 3 Removing demolished material ie building material concrete debrisof any type etc to a distance of 09 KM beyond and up to 10 KMout of premises of metropolition area including loading, unloading by manually or by mechanical means (JCB to be transported through trolly or tipper) and stacking at the destination as and when directed by Engr-In-Charge complete all as specified and as directed 4 M&LPCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in roof/chajja padding for maintaining roof/chajja slope and as in copings including formwork complete all as specified and as directed 5 M&L Pre-cast cement concrete block masonry in PCC 1:3:6 type C1(20mm graded aggregate)with solid blocks, exc. 10cm in width and setting in mortar 1:6 completeall as specified and as directed. 6 Demolition of Brick work or stone masonry built in cement mortar including all quoins, arches, pillars etc., butexcluding ashlar facing dressed stone works and pre-cast concrete articles completeall as specified and as directed. 7 Taking down cement plaster on brick or stone walls,/ceiling etc. including raking out joints, hacking for key, scrubbing down with water, etc completeall as specified and as directed. 8 M&L rendering 15 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement motor 1:4 finished even and smooth without using extra cement complete all as specified and as directed. 9 M&L preparation of old/new plastered surface of wall incl complete removal of existing treatment and applying Two coats of exterioremulsion paint over one coat of one coat of damp proof exterior primerthrough mechanical means complete all as specified and directed. 10 S&F High strength, deformed steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking and binding with mild steel wire (annealed) not less than 0.90mm dia complete all as specified and directed. 11 M&L Granite 18 to 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and tabil top for fixing wash basin and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite shade includingscreed bed or bedding layer of mortar 20 mm thick in cement mortar 1:4 for laying floor finishesall as complete all as specified and directed. 12 M&L for Preparation of old painted steel surfaces of any description over 10cm width or girthand applying one coat of synthetic enamel paint complete all as specified and directed. 13 ITEMS APPLICABLE FOR JOB A 14 M&L for water proofing treatment on horizontal and vertical surfaces with Providing and laying / fixing TPO (Thermoplastic Polyolefin)membrane inclCleaning the surface and laying of 200GSM Geo textile and cover up with TPO RF 1.2 mm thermoplastic membrane on roof & up to 300 mm of parapets and crumple joint including junction of roof and parapet, welding the seam joints with hot airgun/machine and terminate the corners with extra protection to bear the high wind pressure. The TPO should be thoughroly tightened with the lower structure using mechanical fastening properly to avoid the corners and seam joint failure.Make :Asian paints TPO or techno commercially equivalentproduct of M/s Berger / M/s Bauchemic/CIPY/SIKA/Pidilite/Dr fixit TO membrane complete all as specified and directed. 15 Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. 16 M&L Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and as directed 17 M&L for providing cement concrete type B-1 1:2:4 using 20mm graded aggregate as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed. 18 M&L rendering 10 mm thick cement mortar 1:3 on roof paddingfinished even and fair with approved water proofing compound @ 3% by weight of cement or as per manufactures instruction including taking down existing cement plaster/lime plaster all as specified and as directed.(Note : WPC shall be measured and paid seperately as supply only under relevant item) 19 Supply only liquid water proofing compound complete all as specified and directed. 20 M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement morter 1:6 finished even and smooth without using extra cement complete all as specified and as directed. 21 M&L rendering 10mm thick cement plaster on fair faces of concrete surfaces in ceiling/chajjas in cement motor 1:3 finished even and smooth without using extra cement complete complete all as specified and directed. 22 M&L for preparing new plastered on ceilingand applying three coats of white wash through mechanical means complete all as specified and as directed 23 M&L preparing of surface and applying two coats of white wash to old treated plastered or un-plastered surfaces of ceilling including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots complete all as specified and directed. 24 M&L for preparing new plastered surfaces of wall and applying three coats of white wash through mechanical means complete all as specified and as directed. 25 M&L for preparing and applying one coat of white washto old treated plastered or un-plastered surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots complete all as specified and directed. 26 M&L for preparing and applying one coat of synthetic enamel paint to old painted wooden surfaces of any description, not otherwise described, over 10 cm width or girth complete all as specified and as directed. 27 Taking up or down steel tubing and connections, fittings etc including cleaning for refixing or removal to store for15mm bore complete all as specifiedand as directed. 28 Taking up or down steel tubing and connections, fittings etc including cleaning for refixing or removal to store for20mm bore complete all as specifiedand as directed. 29 Taking up or down steel tubing and connections, fittings etc including cleaning for refixing or removal to store for25mm bore C 30 S&F GI tube medium grade with all fittings 15mm boreand connections, complete all as specifiedand as directed. 31 S&F GI tube medium grade with all fittings 20mm bore and connections, complete all as specifiedand as directed. 32 S&F GI tube medium grade with all fittings 25mm boreand connections, complete all as specifiedand as directed. 33 Refixing old steel tubing and connections,fittings etc in new or old position (Walls, ceiling, floors, etc.) 15 mm bore complete all as specifiedand as directed. 34 Refixing old steel tubing and connections, fittings etc in new or old position (Walls, ceiling, floors, etc.) 20 mm bore complete all as specifiedand as directed. 35 Refixing old steel tubing and connections, fittings etc in new or old position (Walls, ceiling, floors, etc.) 25 mm bore complete all as specifiedand as directed. 36 S&F in repairs 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specifiedand as directed. 37 S&F in repairs 25mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specifiedand as directed. 38 S&F in repairs ball brass valves, 25mm diabore high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specifiedand as directed. 39 S&F in repairsball brass valves, 20mm diabore high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specifiedand as directed. 40 S&F 1000 Ltrs Capacitytriple layered Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part I , including dismantling existing 1000 Ltr water tanks complete all as specifiedand as directed. 41 Disconnecting existing tanks, setting aside or lowering ifrequired for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in old or new location position capacity exc 500 & n exc 1000 ltr complete all as specifiedand as directed. 42 Demolition of cement concrete in ground floor and paving n/exe 15 cm thick below or above GL complete all as specifiedand as directed. 43 M&L for 75 mm thick PCC 1:3:6 type C1 (using20 mm graded aggregate ) as insub for receiving floor finishes/plinth protection etc complete all as specified and directed. 44 M&L for 25mm thick PCC 1:2:4 typeB1 (20mm graded aggregate) as in sub base/levelling course complete all as specified and directed. 45 M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed bed or bedding 20mm thick in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. 46 M&L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar with and including 10 mm thick backing coat of cement mortar 1:3 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completeall as specified and directed. 47 M&L for Hard core Broken stone or bouldersof gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. 48 M&L for 100mm thick PCC (1:2:4 type B1 (using20 mm graded aggregate ) as in sub-floors ,sub-base ,floors and pavings complete all as specified and directed. 49 M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engr-In-Charge. 50 M&L 100mm thick machine pressed precast concrete interlocking colouredpaver blockwith grey cement and pigment, any shape and size confirming to IS 15658-2006 , M-50 grade laid over 50 mm thick sand cushion complete all as specified and directed. 51 M&L Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainageopening wherever required complete all as specifiedand as directed. 52 M&L for precast cement concrete 1:2:4, type B-1 using 20 mm graded stone aggregate as in cover slabs and the like, set in cement mortar 1:6 with plain fair faces complete with joints to match complete all as specifiedand as directed. 53 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sq m on plan and getting out hard/dense soil complete all as specifiedand as directed. 54 M&L for PCC 1:4:8 Type D2 (40mm graded stone aggregare) in foundations, filling and mass concrete complete all as specifiedand as directed. 55 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.of hard/dense soil complete all as specifiedand as directed. 56 M&L for Formwork to sides flat rough finished of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. 57 M&L RCC Nominal Mix, 1:2:4 Type B1 (20mmgraded aggregates), foundations including rafts, footings, foundation beams, plinth beams and mass concrete complete all as specified and directed. 58 M&L Formwork to sides of rough finished surface of square concretecolumns complete all as specified and directed. 59 M&L RCC design mix,M-25 (20mmgraded aggregates), Columns, pillars, piers, posts and strutscomplete all as specified and directed. 60 S&F TMT bars 5mm dia and over upto and including 10mm dia in stirrups ,spacers and binders, cut to length bent to shape required, including cranking,bending spirally for hooping for columns,hooking ends and binding with mild steel wire( annealed) not less than 0.9mm dia complete all as specified and directed. 61 S&F mild steel Plates (plain or chequered) channels,distance pieces, cleats etc.square cut or notched including riveted, bolted or welded attachment complete all as specifiedand as directed. 62 S&F mild steelFramed work such as grills ,shouldered and/or riveted,or forged into spikes; framed,guard bars; barred iron doors;ladders; framed balusters; walk,ways; railings; framework of water tanks and similar work,conforming to Fe.290.Gde-E-165 complete all as specifiedand as directed. 63 S&F 1.6 mm Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles,complete all as specifiedand as directed. 64 M&L Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specifiedand as directed. 65 Excavation in post holes each n. exc 0.50 cum in any type of soil ,getting out, returning filling in and ramming earth or broken rubble mixed with earth around , in layers not exceeding 25 cm ,watering and removing surplus soil to a distancen.exc 50m and making good surface complete all as specifiedand as directed. 66 M&L Plain cement concrete in foundation PCC 1:2:4 type B2 using 40mm graded stone agg as in foundation filling or mass concrete for fencing post complete all as specifiedand as directed. 67 S&F Posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, welding etc. and similar work conforming to Fe-290 Gde E-165 complete all as specifiedand as directed. 68 M&L for Preparation of untreated new steel surfaces of any description n.exc 10cm width or girth and applying two coats of synthetic enamel paint ( 1st grade quality ) over a coat of red oxide primer complete all as specified and as directed. 69 Supply only Chain link MS galvanised fencing, any size or type complete all as specifiedand as directed. 70 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provision of binding wire complete all as specifiedand as directed. 71 S&F Galvanised 2 strand barbed wire 2.24 mm dia of wire and 2mm dia of barbed at 75mm spacing and straining and fixing to any type of strandre nails straining bolts, including securing or tying at crossing with and provn of galvanised MS wire staples or steel pins complete all as specifiedand as directed. 72 Taking down carefully copper/aluminiumpoint wiring (light fan socket or power) complete including fittings & fixturessuch as switches, ceiling rose, pendants, regulators, sockets, ceiling roses,pendants, regulators, light fittings etc and making good disturbed surfaces of walls, floors, etc. complete all as specifiedand as directed. 73 M&L for Concealed point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with all PVC conduit accessories, incl metal flush box of 1.60 mm thick suitable for modular switches/ sockets/fan regulators incl modular white cover plate and modular metal flush box with frame of required modules with, blanking plates,brass screws, cup washers etc including all cutting / chases etc in stone/ brick masonary/ walls, pinning in stone walls / brick walls and pointing in cement mortar 1:3 to ends or edges of landing etc for concealed conduit using heavy duty stone drilling/cutter machine and making good to the disturbed surfaces to match the existing complete all as specified and directed for the following:- 74 One light point controlled byone way switch 06 Amps 75 One wall/ceiling fan point controlled by one way switch 06 Amps 76 One exhaust fan point controlled by one way switch 06 Amps 77 One 3 pin, 06 Amps socket outlet point on independent board controlled by one way 06 Amps switch 78 One 3 pin, 06 Amps socket outlet point on same board controlled by one way 06 Amps switch 79 All as per Sl Item no 73.00 here-in-before but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one way switch on independent board. 80 S&F Modular switch, 10 Amps, single pole, one way, 230 volts, one module complete 81 S&F Modular switch, with indicator, 16 Amps, single pole, one way, 230 volts complete 82 S&F Modular socket outlet 05 Pin, 06 Amps, 02 module with shutter complete 83 S&F Modular socket outlet 02 in 01, 03 pin,16 Amps, 02 module with shutter complete 84 S&F Ceiling rose, 65 x 50 mm surface type with 3 terminals incl connection complete 85 S&F in replacement on surface/wall mountedLED batten, robust extruded aluminium housing and intigrated electronic drive20 watt, 4 feet, with accessories including connection with 2 core flexible copper conductor cable of suitable size from ceiling rose complete all as specifiedand as directed. 86 S&F in replacement energy saving security LED light fitting, 36 watt, Versatile pressure die-cast aluminium IP 65/66 with high power LED as light source comprising with electronic driver and all accessories pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 sqmm 3 core, fitting to be fitted on building with bracket made out of 40 mm bore light grade GI tube of suitable length, bend to shape and fixed to wall / pole by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete all as specifiedand as directed. 87 S&F Wall mounted fan, 400 mm sweep, 230/240 Volt, single phase, 50 watt, 1320 rpm, air delivery 70 CMM, oscillating type, 3 speed push button control, to be fitted on wall with necessary arrangements incl connection complete 2 module, hum free, AC, 230 volts, 100 watts complete all as specifiedand as directed. 88 S&F Ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, 02 module, humfree, AC, 230 volts, 100 watts complete all as specified and directed 89 S&F Ceiling fan complete with three blades,down rod, accessories230 V, 1200 mm sweep, min air delivery 210 CFM, BEE 5 star rated with brushless direct current motor incl connection complete all as specified and directed. 90 S&F Exhaust fan 380 mm sweep heavy duty, steel body, AC, single phase 230 volts, 50 Hz, with blades, frame and louvers shutter with necessary hole drilling in wall and making good the disturbed surfaces incl connection complete all as specified and directed. 91 M&L for sub main wiring with 10.00 Sqmm nominal cross sectional area, four single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 10.00 Sqmm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit not less than of 25 mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in stone/ brick masonary/ walls and making good to the disturbed surfaces to match the existing complete all as specified and directed.Note-Four runs of 10.00 sqmm single core cable and one run of 10.00 sqmm earth wire including PVCcasing & capping together shall be measured as one unit. 92 All as per Item No 86.00 here-in-before but for 02 x 4.0 Sqmm for phase & neutral and 01 x 4.0 Sqmm for continuous earth wire in 20 mm PVC conduit complete all as specified and directed. 93 M&L for Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron wire 4 mm dia as earth lead up to test point with suitable size GI nuts/bolts, washers,check nut and brazed properly up to main board,LT panel etc and adequate quantity of charcoal and salt 15 cm around the earth plate including earth pit in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregates,40mm thick precast RCC cover in 1:2:4 reinforced with 8mm dia TMT bars 3 Nos both way including CI cover 10 mm thick with hingedand frame of angle iron 25x25x6mmwith 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil and including medium grade GI watering pipe 20mm bore with funnel and wire mesh and medium grade GIprotection pipe 15 mm bore up to main board complete all as shown in electrical plate no 3 of MES schedule Part-I , connected to earthing testing point and testing on completion complete all as specified and directed.Note: (i) The unit rate includes 15 mm dia GI pipe up to 7.5m for protection of earth lead. (ii) The unit rate includes galvanised iron wire 4 mm dia from earth electrode to test point up to 7.5 meter (iii) In case measured value of earth resistance of each earthingis recorded more than 3 ohms then the earthing shall be re done by the contractor without any extra cost to the department. 94 M&LEarth Continuity Conductor or main earthing lead fixed to wall on batten or recess or chasis or buried in ground or drawn in conduit / pipe or fixed for earthing etc. of size 4.00 mm dia galvanised iron or steel wire complete all as specified and directed. 95 S&F Sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 08 ways with 200 Amps rated copper bus bar and metal double door, IP 43 protection, suitable for MCCB 4 pole 125 amps as incomer and MCB SPs as outgoing along with cable end box for above DB and concealed flush in wall including all cutting chases / civil work as required incl connection and taking down old unsv DB complete all as specified and directed .(Note : MCCB & MCB SPs shall be measured and paid seperately) 96 S&F Sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 08 way, with 200 Amps rated copper bus bar and double door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting / civil wk etc in wall as required complete all as specified and directed . 97 S&F Sheet metal enclosures with socket plug top and MCB, Single pole & neutral enclosure with a 2 pin & earth plug & socket complete with one single pole MCB 20 amps, C curve incl connection complete all as specified and directed 98 S&F MCCB 125 amps, 4 Pole, 415 volt, AC, fixed type, with breaking capacity 16 KA suitable for load line/ VTPN DB & connection complete all as specified and directed . 99 S&F MCB SPN 40 amps, 240 Volts, AC of breaking capacity 10 KA,C curve and connections by using suitable copper lugs complete all as specified and directed . 100 S&F MCB SP, AC, 240 volts of 06 to 32 Amps capacity B curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and directed . 101 Dismantling of Exisiting DG Set 75 KVA With AMF Panel and LT Panel board complete and shifting to other place Up to 400 Mtrs Including Reinstallation of DGSet 75 KVA With AMF Panel and LT Panel board complete testing and Commisioning complete all as specified and directed . 102 Excavation in trenches not exc. 1.5m wide and not exc 1.5m in depth and getting out in soft /Loose soil for laying of cable complete all as specified and directed . 103 Removal of surplus soil(excavated soil) to a distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed . 104 M&L Sand filling under spread dry in trenches as in cable cushioning complete all as specified and directed . 105 Supply and laying un-reinforced precast concrete cable cover Class LV, Type I,flat,size 250 mm x 150mm x 40mm laid in trenches as in protection of UG cables complete all as specified and as directed. 106 M & LLT UG cable 3.5 corex 50 sq mm 1100 Volts grade XLPE insulated , armored, heavy duty with aluminium conductor laid in trenches or fixed to walls/ poles or passing through pipes with and including,cable glandlugs/ thimbles/ ferrules including connecting, testing and commissioning completeall as specified and as directed. 107 S&FLT UG cable 3.5 corex 70 sq mm 1100 Volts grade XLPE insulated , armored, heavy duty with aluminium conductor laid in trenches or fixed to walls/ poles or passing through pipes with and including,cable glandlugs/ thimbles/ ferrules including connecting, testing and commissioning complete all as specified and as directed. 108 M&L for Earthing complete with galvanised steel earth electrode plate of size 600x600x6.3 mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron strip of size 32 x 6 mm as earth lead up to test point with suitable size GI nuts/bolts, washers,check nut and brazed properly up to main board,LT panel etc and adequate quantity of charcoal and salt 15 cm around the earth plate including earth pit in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregates,40mm thick precast RCC cover in 1:2:4 reinforced with 8mm dia TMT bars 3 Nos both way including CI cover 10 mm thick with hingedand frame of angle iron 25x25x6mmwith 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil and including medium grade GI watering pipe 20mm bore with funnel and wire mesh and medium grade GIprotection pipe 40mm bore up to main board complete all as shown in electrical plate no 3 of MES schedule Part-I , connected to earthing testing point and testing on completion complete all as specified and directed.Note:s (i) The unit rate shall includes 40 mm dia GI pipe up to 7.5m for protection of earth lead. (ii) The unit rateshall includes GI main earthing lead/strip of size 32x6 mm from earth electrode to test point up to 7.5 meter (iii) In case measured value of earth resistance of each earthingis recorded more than 3 ohms then the earthing shall be re done by the contractor without any extra cost to the department. 109 M&L Plain Cement Concrete 1:2:4type B-1(using 20 mm gradedgranite stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. 110 ITEMS APPLICABLE FOR JOB B 111 M&L for Providing precast cement concrete solid building blocks or slabs type C1 1:3:6 using 20mm graded aggregate 10 cm thick(with plain or interlocking joints as directed) and setting in cement mortar 1:6 complete all as specified and directed. 112 M&L RCC nominal mix M-25 using 20mm graded aggregates inSlabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. 113 M&L for Formwork to soffits of rough finished surface of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. 114 M&L for Formwork to edges/sides of rough finished surface of roof slab 15cm thick complete all as specified and directed. 115 M&L 100 mm thick Cement concrete type D2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring or pavings complete all as specified and directed. 116 Dismantling floor hearth or wall tiling including cement morter bedding but not backing coat removing serviceable tiles to store and rubbish off premises etc complete all as specified and as directed. 117 M&L for Non skid ceramic coloured joint free tiles 7to 8mm thick (square/ rectangular), area of each tiles exceeding 0.11 sqm but n exc 0.18 sqm, in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles,laid over and including cement screed bed 15 mm thick in cement mortar 1:6 laying floor finish complete all as specified and directed. 118 M&L for Glazed ceramic coloured tiles in vertical surfaces 300 x200x7/450x300x7 mm thick , set and jointed in neat cement slurry and pointed in white or colour cement to match laid over 10mm thick cement plaster in cement mortar 1:4 complete all as specified and directed. 119 M&L 18/19mm thick block board ,grade 2 quality interior grade , commercial typefixed with screw to timber frame work includingtaking downcomplete all as specified and directed. 120 M&L Decorative laminate type 1 of0.9 mm thick surface finish, colour and pattern as approved, fixed with approved adhesive as manufacturers complete all as specified and directed. 121 S&F Continious piano hinges, continuous type of mild steel bright finish or electrogalvanized with width of flap (when open) 30mm complete all as specified. 122 S&F 75mm long Brass handle, cast type, polished brightfixed with nut and screwsto cupboard shutter complete all as specified and directed. 123 S&F 150mm long Brass handle, cast type, polished brightfixed with nut and screwsto cupboard shutter complete all as specified and directed. 124 S&F Magnetic ball catches with 8mm dia steel ball brass body and striking plate including letting in and fixed, complete all as specified and directed. 125 Complete removal of existing treatement on wall and applying two coats of oil emulsiondistemperover one coat of chalk whiting primer over and including 3 mm thick wall care putty complete all as specified and directed. 126 S&F Sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mmx460mm bowl size 410mmx330mmx160mm, fixed as in repairs, complete all as specified and as directed. 127 ITEMS APPLICABLE FOR JOB C 128 S&F U Shaped SS Rail wall andfloor mounted 600x100mm with anti slip coating ideally for elderly and specially abled people of Make Cera : Cat Part No B2210101 or techno commerciallyequivalent in Jaguar complete all as specified and directed. 129 S&F Hand railwall mounted hinged hand rail 600x100mm SS bars with anti slip coating ideally for elderly and specially abled people of Make Cera : Cat Part No B2210102 or techno commercially equivalent in Jaguar complete all as specified and directed. 130 S&F L Shapedgrab bar wallmounted inverted L shapedgrab bar with500 and 700mm long mm SS bars with anti slip coating ideally for elderly and specially abled people of Make Cera : Cat Part No B2210103 or techno commercially equivalent in Jaguarcomplete all as specified and directed 131 S&F corner grab bar wallmounted corner grab bar with500 and 600mm long mm SS bars with anti slip coating ideally for elderly and specially abled people of Make Cera : Cat Part No B2210104 or techno commercially equivalent in Jaguar complete all as specified and directed 132 S&F grab bar wall350mm long mm SS bars with anti slip coating ideally for elderly and specially abled people of Make Cera : Cat Part No B2210105 or or equivalent in Jaguar complete all as specified and directed 133 S&F grab bar wall600mm long mm SS bars with anti slip coating ideally for elderly and specially abled people of Make Cera : Cat Part No B2210106equivalent techno commercially in Jaguar complete all as specified and directed 134 S&F hand railwallmounted hinged hand rail 600x100mm SS bars with anti slip coating ideally for elderly and specially abled people of Make Cera : Cat Part No B2210107 orequivalent in Jaguar complete all as specified and directed 135 S&F hand railwallmounted hinged hand rail 750x100mm SS bars with anti slip coating ideally for elderly and specially abled people of Make Cera : Cat Part No B2210108equivalent in Jaguar complete all as specified and directed