| 1 | Up-gradation, upkeeping and Operation of Audio-Visual (AV), HVAC, AC, mechanical, Electrical, electronics, special effects, equipments/installations, preparation of halls, back stage supports, pest control of halls and rooms, cleaning of equipments and setup of audio-visual system for indoor and outdoor programs.Supply of eight set of first Add boxes, PPE, dress of deputed manpower, tool kit with bags, instruments, equipments, stationary items like registers, markers, pen, erasers, pages required for printing, scale,dairies, cotton waste, LT insulating tapes and CRC, CTC,broom, cobweb broom, mop, bucket dustbin, soap, hand-wash liquid, tissue paper, detergents and phenyl etc.Setting, fixing, configuration and maintenance of systems as per standard requirements of Seminars, Lectures, workshops, theme meetings, national celebrations and cultural programs etc. to be conducted in RRCAt campus. Contractor shall provide three/four wheeler electric vehicle having sotarage capacity to transport the systems in RRCAT Campus. For detailed scope of routine works please refer 1E1 to 1E22 of Specifications of work. |
| 2 | ERW MS Conduit :- Supply and installation of ERW MS concealed/open conduit system with all accessories and material required for fixing is in the scope of item. For detailed scope of routine works please refer 2E5.1 to 2E5.2 of Specifications of work. |
| 3 | 25mm conduit. |
| 4 | Supply, installation, termination, testing and commissioning of FRLSFlexible copper/ audio-video wire/cable.For detailed scope of routine works please refer 2E6 of Specifications of work. |
| 5 | 1.0 sq.mm |
| 6 | 1.5 sq.mm |
| 7 | 2.5 sq.mm. |
| 8 | 4 sq.mm /Shielded Audio-Video cables and other audio and network related cables. |
| 9 | Dismantaling of old wiring and acessories mountedon walls/ roof /ceilings from existing installation and stored within 2 kM radious area with proper marking as directed by Deprtment official.For detailed scope of routine works please refer 4E11 of Specifications of work. |
| 10 | conduits/ casing-n-capings/ducts/Cable management system/cable tray andassociated all type of wires/cables etc. |
| 11 | Dismantaling ofSwitch boards/AC Point/MCB/SFU etc. from walls from existing installation and stored within 2 kM radious area with proper marking as directed by Deprtment offcial. |
| 12 | Fabrication, supply and installation of sheet steel as per site requirements. The work includs to fabrication, painting, rubber gasket,locking arrangement,earthing bolt etc.as per requirements.For detailed scope of routine works please refer 4E7&8 of Specifications of work. |
| 13 | Power outlets/Switch Boards: Supply, installation, termination, testing and commissioning of FRLSFlexible copper/ audio-video wire/cable.For detailed scope of routine works please refer 2E9 of Specifications of work. |
| 14 | 6ASPT modular Switch |
| 15 | 16/20ASPT modularSwitch. |
| 16 | 6ASPT modularSocket. |
| 17 | 16A5 pin modular Socket. |
| 18 | RJ-11 telephone sockets. |
| 19 | RJ-45 network (CAT-6) sockets. |
| 20 | Supply and installation of ISI mark Hylem sheet including cutting of switches/sockete/fan regulators as directed by Department official. |
| 21 | Luminaire : - Supply,Installation,testing and commissioning/ Replacement of following LED luminaires and complete with elctronic ballasts/Drivers,lamps and all accessories with required fixing material, down rod and reinforced PVC pipe as per site requirements. The sizes and shape of luminaires shall be matched with existing luminaires as much possible.The contractor shall provide 5 year guarentee for all LED luminaires. 10% of total amount of item no. 8 shall be deducted against security of guarentee. This amount shall be released after lapse of 5 Years without any inetrest.For detailed scope of routine works please refer 2E7 of Specifications of work. |
| 22 | LED bulk head 10W luminaire, having Lumen out put - ≥ 600 Lumens, Colour temperature-4000/4500/5000/5700/6000K, IP- 66, Housing- High pressure die cast aluminium, IK - 09, Cover- UV stablized polycarbonate front diffuser, THD- ≤ 10%at full load and Power factor- ≥ 0.90 and as per detail specifications. Removal of existing luminaire with all accessories and storing within RRCAT campus is in the scope of item. |
| 23 | Surface mounted 7 to 13 watt LED integral luminairewith driver in one compact housing. Luminaire should have nominal efficacy ≥ 120 lm/watt, nominal output as 1500 lumen, Colour temperature : 4000/4500/5000/5700/6000K, CRI ≥ 80, IP:65, THDi: < 10% at full load,2.5 kV surge protection minimum, Optics: exposed lens optics policarbonate, Life Class: L70 @ 50K hrs. & complete with all accessories and driver. Removal of existing luminaire with all accessories. and stored in within RRCAT campus. |
| 24 | Suitable for outdoor Fancy LED luminaire 70 watt, lumen output 7000 lumen, IP65, CRI>70 and Colour temperature : 4000/4500/5000/5700/6000K in compact housing with driver. Scope shall include removal of existing luminaire with all accessories. and stored RRCAT campus. |
| 25 | 30 watt, 2X2feet LED integral recess mounted fancy type with driver in one compact housing. Luminaire should have nominal efficacy ≥ 100 lm/watt, nominal output as 3000 lumen, Colour temperature : 4000/4500/5000/5700/6000K, CRI ≥ 80, THDi: < 10% at full load,2.5 kV surge protection minimum, Optics: exposed lens optics policarbonate, Life Class: L70B50 @ 40K hrs. & complete with all accessories and driver. Removal of existing luminaire with all accessories, false ceiling repair and storing within RRCAT campus is also in the scope of this item. |
| 26 | Recess mounted LED type downlighter meeting the following specifications:Luminous flux : 1500 lm +/- 10% , Efficacy(min) : 100 lm/W, Colour temperature : 4000/4500/5000/5700/6000K,pf: 0.9(min) , THD : less than 10%,CRI: >80 , Optics: High quality diffuser. Removal of existing luminair with all accessories and storing within RRCAT campus is in the scope of item. |
| 27 | Supply and replacement of36 watt conventional fluorencent lamp with LED tube lightincluding modification in wiring. Lumen output ≥ 2100, CRI ≥80, Efficacy ≥100 lumen/wattminimum, Colour temperature : 4000/4500/5000/5700/6000K and as per detail specifications. Removal of existing lamp andaccessories shall be stored within RRCAT campus. |
| 28 | Supply installation testing and commissioning of cable management system with following items.For detailed scope of routine works please refer 4E12 of Specifications of work. - |
| 29 | 100X50mm PVC body with cover and partition. |
| 30 | End cap |
| 31 | 90 degree angle |
| 32 | Partition Junction internal/external |
| 33 | Cover and body joint |
| 34 | Cable clip |
| 35 | Supply & Installation of ALUMINIUM Cable management/trunking system with all accessoried. Materials required for fixing of Cable management/trunking system and mounting of switchs/Sockets and other outlets on this system will be in the scope of this item.If required preparation and pasting of a sticker related to culture and history of Malwa all along the CMS is also in the scope of this item.For detailed scope of routine works please refer 4E13 of Specifications of work. |
| 36 | 100/105X50mm ALUMINIUM body with covery and partition. |
| 37 | End cap |
| 38 | 90 degree angle/T-Joint or Internal and external angle adjustable from 60 degree to 120 degree angle. |
| 39 | Flat Junction |
| 40 | Cover and body joint |
| 41 | Cable clip |
| 42 | Earth link |
| 43 | Painting the old exterior walls/roof or any other structure with two coats of Snowcryl XT acrylic emulsion/APEX Ultima over one coat primer, of approved shade including preparing the surface by removing loose dust and dirt with stiff brush and washing the surface with clean water, treating the surface with antifungal chemical wherever required, filling with putty, scaffolding and cleaning etc. complete. For detailed scope of routine works please refer 4E14 of Specifications of work. |
| 44 | Painting of Street light Poles : Painting steel work in two coats of Aluminium paint of approved shade and make over one coat of steel primer including preparing surfaces, scaffolding and cleaning, tools & tackles, safety appliances etc. complete.For detailed scope of routine works please refer 4E14 of Specifications of work. |
| 45 | Supply and installationof GI strip/ bare wire of required size under ground at a depth of 600mm from FGL including excavation,black bitumin painting,backfilling and consolidation og soil. Installation of GI strip along cable tray/wall using GI clamps at interval of 500mm as per site requirement including required hardware as per tender specifications.For detailed scope of routine works please refer 3E5 of Specifications of work. |
| 46 | Earth Pit Chambers: Construction of earth pit chambers including 0.23 M³ PCC steel reinforced, 400x400mm cast iron cover. This includespainting and stencling on chamber and coveras per tender specifications. For detailed scope of routine works please refer 3E of Specifications of work. |
| 47 | Supply of MS AV troly suitable for mounting of two nos. 160 Watt outdoor speakers, amplifiers and related items of audio systems. The wheels of trolly should suitable for movement on roads. It should have inbuilt power distribution system and available with single point power input. The drawing, size and mounting details of trolly shall be approved by the deparment. |
| 48 | LED Focus/Spotlight luminaire suitable to form a circle of min 2m dia at stage and mounted at distance of 12-16m from stage. The illumination level of circle shall be 500 to 1000 lux and CCT will 2400 to 2900. |
| 49 | Note: 1. The Rate shall be inclusive of GST, other Taxes, Materials transportation and downloading at site, Installation and testing cost, comprehenshive warantee for One year and contractor\"s profit. 2. The stenciling work of whole installation will be done by the bidder, work done by him or other agency. 3. If AMC/maitinance of equipments taken underitem no. 1 is required to be done by OEM the rates of OEM is also included in the rate of item no.1. 4. Six sets of executed drawing of installation should be submitted by the contractor at the time of completion of works. 5. The tentative list of equipments are given in list of equipments. |