Construction Of Aam Sc Stok (Under Nhm)+Earth work in excavation by mechanical means (Hydraulic excavator) overareas (exceeding 30cm indepth,1.5minwidthaswellas10sqmonplan) including getting out and disposal of excavated earth lead upto 50m and lif tupto1.5m, as directed by Engineer-in-charge. a) All kinds of soil 2 b) Hard rock (Blasting Prohibited) 3 c) Ordinary rock 4 Earth work in excavation by manual means in foundation trenches or drains (not exceeding 1.5m in width or 10sqm on plan), includingdressingof sides and ramming of bottoms, lift upto1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 5 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm indepth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 6 Dumping stone Including cost of stones. in Horizontal on level 7 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) 8 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete1:6:12(1cement :6 coarses and:12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) 9 Randomrubblemasonrywithhardstone laid dry infoundation, plinth & walls Laid without bond stone 10 Structural steelwork insinglesection, fixedwithorwithout connectingplate, including cutting, hoisting, 11 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mmincluding strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm 12 Centering and shuttering including strutting, propping etc. and removal of form for a) Foundations, footings, bases of columns, etc. for mass concrete 13 b) Suspended floors, roofs, landings, balconies and access platform 14 c)Lintels, beams, plinth beams, girders, bressumers and cantilevers 15 d)Columns, Pillars, Piers, Abutments, Posts and Struts 16 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : a) 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) 17 b) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 18 Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 19 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement- All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 20 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 21 Providing & fixing stabilized mud concrete solid blocks (adobe) with 3% cement, masonry up to floor five level including hoisting and setting in position in cement mortar 1:6 using approved quality mud with carriage of material complete. 22 Providing & fixing upto floor five level precast cement concretesolid blocks including hoisting and setting in position in cement mortar 1:3 (1cement:3 coarse sand), cost of requiredcentring,shuttering and curing complete1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20 mm nominalsize) 23 Randomrubblemasonrywithhardstone laid dry infoundation, plinth & walls Laid without bond stone 24 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete1:6:12(1cement :6coarsesand:12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) 25 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (holdfast lugs or dash fastener shall be paid for separately). Second class Kail wood 26 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:-Butt hinges and necessary screws shall be paid separately) Second class teak wood 35 mm thick shutters 27 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.First class kail wood 28 Float glass panes 4 mm thick glass pane (weight not less than 10kg/sqm). 29 Providing and fixing traditionally carved wood work (Shingstak) over doors and windows including all accessories as per the direction of the Engineer in-charge, complete with; 2nd class kail wood 30 Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Wedge expansion typeFastener with threaded dia 10 mm 31 Providing and fixing PTMT Tower Bolts with 12 mm one piece rod inside and necessary screws etc., complete. A) 152x42x18 mm weighing not less than 60 gms 32 b) 202x42x18 mm weighing not less than 78 gms 33 Providing and fixing oxidisedM.S. casement stays (straight peg type) with necessary screws etc.complete.200 mm weighing not less than 120 grams 34 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. A) 125x70x4 mm (ordinary type) 35 b) 75x40x2.5 mm (ordinary type) 36 Providing and fixing ISI marked oxidised M.S. handles conforming toIS:4992 with necessary screws etc.complete : a) 100 mm 37 b) 125 mm 38 Providing and fixing 12 mm thick pre laminated flooring of approved brand as per direction of engineer incharge, complete job AC-4 including carriage. 39 Providing and laying gang saw cut 18 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 5 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. With granite stone of area less than 0.50 sqm. 40 Providing and layingVitrified tiles in floor indifferent sizes (thickness to be specified by themanufacturer) withwater absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colour sand shade, laid on 20mm thick cement mortar 1:4(1 cement:4 coarse sand) jointing with grey cement slurry @3.3kg/sqm including grouting the joints with white cement and matching pigments etc.The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 41 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. 42 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 43 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand) 44 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) 45 Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) 46 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : Newwork (two or more coats) over and including water thinnable priming coat with cement primer 47 French spirit polishing : Two or more coats on new works including a coat of wood filler 48 Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete. 49 Providingandfixing 100mm Pinewoodplainliningtonguedandgrooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface. 10 mm thick 50 Steelwork in builtup tubular (round, squareor rectangular hollow tubesetc.) trusses etc., including Hot finished welded type tubes 51 Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size betweencavity wall, complying with ISO 4898:2008 & ASTM C 578 08b- type VI, having thermal conductivity of0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of > 350 kPa listed asper ASTM D1621, density of 34-36 kg/m3 as per ASTM D 1622, water absorptions < 1% by volume as perASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) asper ASTM D 3576. Fire retardent property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 classA, fixed with suitable water based adhesive and fastener, complete in all respect as per the direction of Engineer-in-Charge. 52 Providing and filling of saw dust in the gap between the insulation and wall with all complete job 53 Carriage of material from source to site by M.T including loading, unloading and complete job a) Cement an average lead upto 13km 54 b) Sand an average lead 5kms 55 c) Coarse aggregate average lead 5km 56 d) Stone an average lead 5km 57 Providing and fixing 3 layer PP-R (Polypropylene Random copolymer) pipes SDR 7.4UV stabilized & anti-microbial fusion welded, having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings i/c trenching. refilling & testing of joints complete as per direction of Engineer in Charge. (External work) PN-16 Pipe, 25 mm OD (SDR-7.4) 58 Providing and fixing 3 layer PP-R (Polypropylene Random copolymer) pipes SDR 7.4UV stabilized & anti-microbial fusion welded, having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Chajge.(Concealed work including cutting chases and making good the walls etc.,) PN-16 Pipe, 32 mm OD (SDR-7.4) 59 Providing and fixing PPR Unionsa) PPR Union32mm 60 b) PPR Union 25mm 61 Providing and fixing water closet squatting pan (Indian typeW.C. pan ) with 100mm sand cast Iron P or S trap,10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. 62 Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4(1 cement : 4 coarse sand) for fire hydrants, with C.I. surface box 350x350 mm. top and 165 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement: 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With F.P.S. bricks 63 Providing and fixing wash basin with C.I.brackets,15mm C.P.brass pillar taps, 32 mm C.P. brasswaste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 630x450mm with a pair of 15mm C.P. brass pillar taps. 64 Providing and fixing Stainless Steel A ISI 304(18/8) kitchen sink as per IS1 3983 with C.I.bracket sand stainless steel plug 40mm including paintingof fitting sand brackets, cutting and making good the walls wherever required: Kitchen sink with drain board 17.10.1.1 510x1040 mm bowl depth 250mm. 510x1040 mm bowl depth 250mm. 65 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing :Rectangular shape 1500x450 mm 66 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements weighing not less than 106 gms. 67 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 68 Providing and fixing toilet paper holder : C.P. brass 69 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement, trenching,refilling & testing ofjointscompleteasper direction ofEngineer in Charge. (External work).a) 100mm nominal inner dia .Pipes. 70 b) 80 mm nominal inner dia Pipes. 71 Providing and fixing plain bend of required degree. A) 100 mm dia 72 b) 75 mm dia 73 Providing and fixing double equal junction of required degree with access door with fitting complete job. PVCa) 100mm dia 74 b) 75mm dia 75 Providing and fixing PVC collar of required dia complete joba) 100mm dia 76 b) 75mm dia 77 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe 32 mm dia 78 Providing and fixing brass bib cock of approved quality : 15 mm nominal bore 79 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore 80 Providing and fixing gyeser of requird capacity including fixing with all fixture complete job. 25ltr 81 Providing and fixing gun PVC gate valve with C.I wheel of approved quality ( screwed end) 32mm nominal bore 82 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.25mm nominal bore. Weighing not less than 62gms. 83 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI :12701 marked with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fitting sand the base support for tank 84 Providing and fixing of material for the insulation of pipe with nitrile tube , tapping with cello tape for inner wall fittings . complete job including carriage. 19 mm thick, 50 mm dia (OD) ( PPR 25 mmm) 85 Providing and fixing of material for the insulation of pipe with nitrile tube , tapping with cello tape , Rockwood 6 inch per side, wire mesh, polythene , tapping with cello tape aluminum sheet 26 gauge cladding with dia . complete job including carriage. b) 19 mm thick, 50 mm dia (OD) ( PPR 32 mmm) 86 Providing and fixing heat tape 33Watton PPR pipes made of denforced or chromelox or equivalent make, as approved by Engineer InCharge , complete Job 87 Providing and fixing of material for the insulation of Water Storage Tank of with nitrile sheet , tapping with cello tape , Rockwood 6 inch per side, wire mesh, polythene ,aluminum sheet 26 gauge cladding with dia of , complete job. 19 mm thick nitrile sheet 88 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet: 100 mm diameter 89 Providing and fixing PTMT stop cock of approved quality and colour. 15 mm nominal bore, 86mm long, weighing not less than 88 grams. 90 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 91 Wiring for light/ power plug with 2X2.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required 92 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 93 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1 x 1.5 sq. mm 94 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.a) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 95 b) 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 96 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. A) 5/6 A switch 97 b) 3 pin 5/6 A socket outlet 98 c) 15/16 A switch 99 d) 6 pin 15/16 A socket outlet 100 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 101 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). 102 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). 103 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 104 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)a) 6 way (4 + 18), Double door 105 b) 8 way (4 + 24), Double door 106 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 107 Single pole and neutral 32amp 108 Triple pole and neutral 63A 109 Supply, installation, testing & commissioning of GI electrode earthing with 84mm dia and 3 meter length, with 40mm x 6mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristiline Conductive Material (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact between the electrode and compound should be eco-friendly . GI electrode earthing should be maintainance free and does not require regular manual addition of water. The earthing pit should be covered with PVC cover. 110 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 111 Supplying and fixing MCCB in cubical panel board providing and fixing following rating and breaking capacity MCCB FP in existing cubical panel board including drilling of holes in cubical panel and making connections etc. As required (Make as per annexure) Change over switch FP 100 Amp 112 MCCB FP 100 Amp 30 KA 113 Fabrication, supplying, installation testing and commissioning of following panel made out of 2mm thick M.S sheet, wall mounted , vermin & dust proof, indoor type with lockable type hinged doors, duly painted with provision for fixing of 1 no. incomer MCCB type change over switch including supply and fixing 1 set of aluminium bus bar and strip for housing MCBs 72 Nos. MF digital meter and other allied accessories as required. ( Make as per annexure) 114 Supplying and fixing following luminaries as required 10 watt LED tube light fitting Philips or equivalent 115 20 watt LED tube light fitting.Model/equivalent make and model Philips. 116 Supplying & fixing LED type down lighter 15 watt Philips or equivalent. 117 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm 118 Supplying and fixing of 120 watt LED street light complete with GI pipe bracket duly embeded along the paraper/wallWipro LRO2-132-XXX-57-G2 or equivalent approved make