Tender For Civil And Miscellaneous Repair Work In Zone 02 Area ,Jda, Jaipur (Arc) - Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of asonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per MoRD Specification Clause 202.By Mechanical Means Cement Concrete 2 Dismantling Brick/Tile WorkDismantling of existing structures like culverts, bridges,retaining walls and other structures comprising of brickmasonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per MoRD Specification Clause 202. Cement mortar 3 Dismantling of existing structures like culverts, bridges,retaining walls and other structure comprising of stonemasonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per MoRTH Specification Clause 202. Rubble Stone Masonry in Cement Mortar 4 Dismantling of cement concrete pavements by echanicalmeans using pneumatic tools breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately 5 Dismantling Kerb Stones Dismantling kerb stones by manual means and disposal of dismantled material with all lifts and upto a lead of 1000 m as per MoRTH Specification Clause 202.Construction of Embankment with Material Obtained from Borrow Pits 6 Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, ransporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300-1 and 300-2 with a lead upto 50 m as per MoRTH Specification Clause 305.3 7 Interlocking Concrete Block Pavement with M-30 Grade 0.30 Mtr x 0.30 Mtr x 0.15 Mtr Edge Blocks (measurements shall be made inner to inner side of edge blocks) Providing and Laying of Interlocking M-30 grade Concrete Block Pavements having thickness 60 mm as per drawings and as per IS 15658:2006.and materials conforming to MoRTH Specification Clause 602 with M-30 Grade 0.30 Mtr x 0.30 Mtr x 0.15 Mtr Edge Blocks.Category ‘B‘ : Dentated only two side like I,Z,T shape as per IRC:SP:63-2004 8 Providing and Laying of Interlocking M-30 grade Concrete Block Pavements having thickness 80 mm as per drawings and as per IS 15658:2006.and all materials shall conform to MoRTH Specification Clause 602 with M-30 Grade 0.30 Mtr x 0.30 Mtr x 0.15 Mtr Edge Blocks.Category ‘B‘ : Dentated only two side like I,Z,T shape as per IRC:SP:63-2004 9 Providing and Laying of Interlocking M-30 grade Concrete BlockPavements having thickness 100 mm as per drawings and as per IS 15658:2006.and all materials shall conform to MoRTH Specification Clause 602. with M-30 Grade 0.30 Mtr x 0.30 Mtr x 0.15 Mtr Edge Blocks.Category ‘B‘ : Dentated only two side like I,Z,T shape as per IRC:SP:63-2004 10 Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 2905. 300 mm dia 11 Providing and fixing of retro-reflectorised cautionary,mandatory and informatory sign as per IRC:67 made ofencapsulated lens type reflective sheeting vide Clause 801.fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and MoRTH Specification Clause 801900 mm equilateral triangle 12 600 mm equilateral triangle 15.000 3,696.00 Each 13 A. 600 mm circular 15.000 5,050.00 Each 14 800 mm x 600 mm rectangular 5.000 7,161.00 Each 15 600 mm x 450 mm rectangular 10.000 4,917.00 Each 16 900 mm side octagon 5.000 9,218.00 Each 17 Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 801.3.1. fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on 2 inch dia GI Pipe firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and MoRTH Specification Clause 801,upto 0.9 sqm size board. 18 Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and MoRTH Specification Clause 801 Painting on Steel Surfaces 19 Providing and applying two coats of ready mix paint including primer coat of approved brand on steel surface after through cleaning of surface to give an even shade as per drawing and MoRTH Specification Clause 801 G.I Barbed Wire Fencing 1.2 m high 20 Providing and fixing 1.2 m high GI barbed wire fencing with 1.8 m RCC posts 150 mm x 150 mm placed every 3 m centre-to-centre founded in M15 grade cement concrete, 0.6 m below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 9 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc. complete as per MoRTH Specification Clause 808.G.I Barbed Wire Fencing 1.8 m high 21 Providing and fixing 1.8 m high GI barbed wire fencing with 2.4 m RCC M15 grade 150 mm x 150 mm concrete post placed every 3 m centre-to-centre founded in M15 grade cement concrete, 0.6 m below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontallines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc. complete as per MoRTHSpecification Clause 808. 22 Marking Centre Line and stop lines etc. on road as per IRC pattern with thermoplastic paint of approved quality and make with 8% glass beads laid on the road surface at temperature 160 C with a special applicator machine complete with a special applicator machine complete with labour material and traffic diversion arrangements 23 Providing concrete for plain/reinforced concrete in openfoundations complete as per drawings and MoRTHspecifications Clause 1702, 1703, 2102 & 2104. P.C.C grade M 10. P.C.C. grade M 20 Nominal mix (1:2:4) 24 Stone masonry work in cement mortar in foundation complete as per drawing and MoRTH specifications Clauses 1402, 1405, 2102 & 2104. Random Rubble Masonry . In 1:4 cement mortar 25 Stone masonry in cement mortar for substructure complete as per drawing & MoRD specification Clauses Random rubble masonry In 1:4 cement mortar 26 Providing and Laying Treatment of Wear and Tear Concrete surface with pre-mixed, high performance, curing free, quick setting ready to use cement mortar for repairing of pot holes with minimum 25mm depth and without cutting the panel so that traffic can be mobilized in 4 hours. The high performance Ready Mix Concrete Mortar should be curing free and able to achieve ompressive strength of 10 Mpa within 4 hours andbond strength of 4 Mpa within 24 hours, non shrink and non toxic. 27 Repair of Surface defects in existing cement concrete pavement surface by providing and laying treatment of wear & tear concrete surface with pre-mixed, ready to use, geopolymer based mortar & confirming to ASTM C 1600 upto 10 mm thickness with following roperty–Curing Free, compressive strength of 15 MPa within 2 hours, Quick Setting, bond strength of 4 MPa within 24 hours and repaired surface should be ready to use within 3 hours.Note : (This item is to be used in only emergency situation after decided by Engineer in charge ) 28 Providing & Fixing of ABS Plastic rectangle crumb of Size 250mm X 125mm X 28mm fixing with nail and vicro epoxy at interval for prevent of accident require both side reflector of specific size with visibility at least 100mtr 29 Supply of JCB (excavator cum loader) Type 3D on hire including POL & driver at different sites as Directed by Engineer in charge. 30 Supplying of 35 HP Diesel Tractor Trolly with hydraulic lift Trolley on hire with driver, cleaner and POL at different sites of JDA region as Directed by Engineer in charge. 31 Providing of Mud pump with hose pipe in required length on hire charges with P.O.L., the pump should be completed with suction and delivery attachment as per site requirement. 50 HP Mud pump tractor mounted with driver, operator and helper. 32 Supply of Dumpers on hire charges with driver, cleaner and POL different sites of JDA region as Directed by Engineer in charge 33 Providing and fixing steel gate, grating , and grills made ofangles, tees, square bars, flats,or black pipe with holdfast andfittings complete as per design and drawing including cuttingwelding and fabrication with priming coat of red oxide 34 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse and)Ordinary cement without any pigment 35 Rough Chisel dressed Kota stone 35 mm thick flooring of approved shade set in pattern over 20mm thick base of cement mortar 1:6 (1 cement : 6 coarse sand) and pointing with cement sand mortar 1:3 with pigment to match the shade of stone with joint thickness up to 15 mm complete in all respects : 36 Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: 37 Providing and fixing of Reinforced Ferro cement Drain cover designed for class AA loading duly marked on cover with adequate steel reinforcement having thickness 75 mm to 150 mm anti- corrosive bitumen painted M.S. plate Rim and on M.S. lifting hooks admixture like plasticizer bond improving compound shrinkage resistance compound abrasion resistant complete as per approved design etc.for drain Opeining Size 300 to 450 mm Standard Drain Cover Size 600mm x 800mm x 75mm 38 for drain Opeining Size 451 to 700 mm Standard Drain Cover Size 1000mm x 800mm x 100mm 39 for drain Opeining Size 701 to 1200 mm Standard Drain Cover Size 1500mm x 600mm x 125mm 40 Providing and fixing reinforced concrete precast kerb stone or dand R.Mtr of M-20 grade cement concrete 120 cm long having 4 Nos. bars of 8 mm dia hysd and stirrups 6 Nos of 6 mm dia as per IS with in built provision of interlocking of jointing and lifting compaction of reinforced concrete by mechanical and table vibrators jointing at site with cement mortar 1:4 complete in all respect as directed by Engineer incharge on: 100 mm thick cement concrete 1:4:8 (1 Cement : 4 Coarse sand : 8 stone aggregate 20 mm thick nominal size) including excavation of earth and cutting of BT road cutting of WBM road etc. and disposal of surplus material with all lead and lift. The size of kerb shall be (11.5+16.5)/2*30+(16.5*7.5) 41 Removing & Refixing of precast concrete interlocking paving blocks recovered item from site 60 mm to 100 mm thick laid on average 50 mm thick bed of coarse sand joint be filled with fine sand laying procedure on compacted sub base as define etc. complete as per direction of Engineer-in-charge with all lead and lift. 42 P & F of cement concrete precast kerb or dand of M-20 grade upto 60 cm length over 20 mm thick base of cement mortar 1:6 including earth work, cutting of B/T road, cutting of WBM road etc. & jointing with cement mortar 1:4 grouted 125 mm in ground of shape as approved by Engineer-in-charge. The rates are inclusive of providing, laying and compacting base concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate of 20 mm thick nominal size) 100 mm thick below dand/kerb complete in all respect. The size of kerb be 15 cm x 32.5 cm with round at top