}

Tender For Emf Of Sector 18B, Dwarka Hig Flats Hs-2010.Sh:- Dismantling, Supplying & Fixing Of Fire Fighting , Fire Alarm And Pa System & Allied Accessories At 490 M.S. Hig Houses In Pkt-I, & 457 M.S. Hig Houses In Pkt-Ii At Sector-18B, Dwarka, Ph-Ii., Delhi-Delhi

Delhi Development Authority has published Tender For Emf Of Sector 18B, Dwarka Hig Flats Hs-2010.Sh:- Dismantling, Supplying & Fixing Of Fire Fighting , Fire Alarm And Pa System & Allied Accessories At 490 M.S. Hig Houses In Pkt-I, & 457 M.S. Hig Houses In Pkt-Ii At Sector-18B, Dwarka, Ph-Ii.. Submission Date for this Tender is 23-06-2025. Dismantling Work Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

49653229
Tender For Emf Of Sector 18B, Dwarka Hig Flats Hs-2010.Sh:- Dismantling, Supplying & Fixing Of Fire Fighting , Fire Alarm And Pa System & Allied Accessories At 490 M.S. Hig Houses In Pkt-I, & 457 M.S. Hig Houses In Pkt-Ii At Sector-18B, Dwarka, Ph-Ii.
Tender
Indian
Delhi
Delhi
23-06-2025

Tender Documents

Tender Details

EMF of Sector 18B, Dwarka HIG Flats HS-2010.SH:- Dismantling, supplying & fixing of Fire fighting , Fire alarm and PA system & allied accessories at 490 M.S. HIG houses in Pkt-I, & 457 M.S. HIG houses in Pkt-II at Sector-18B, Dwarka, Ph-II.; 1 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to 1239 in lieu of the same including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing thepipe on the wall/ ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required:150 mm 2 100 mm 3 80 mm 4 50 mm 5 40 mm 6 32 mm 7 25 mm 8 Supplying and fixing of fire brigade connection ofcast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :4 way - 150 mm dia M.S. Pipe 9 3 way - 100 mm dia M.S. Pipe 10 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories:Pendent / Upright Sprinkler 11 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.40 m 12 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 13 Supplying and fixing single headed internal hydrant valve with instantaneous Stainless Steelcoupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank cap and chain as required. 14 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required:80 mm dia 15 100 mm dia 16 150 mm dia 17 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :80mm dia 18 100mm dia 19 150mm dia 20 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80mm dia 21 100mm dia 22 150mm dia 23 Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :150mm dia 24 Reconditioningofthe existing main ElectricdrivenMain Pump/Sprinkler pump Set having a discharge upto2850 LPM at suitable Head coupled to Electric Motor i/c overhauling checking, servicing, greasingnecessary repairs/ replacement of internal defective parts etc. as requiredi/cre-testing & commissioning etc., complete as required. 25 Reconditioningofthe existing main DieselEnginePump Set having a discharge upto 2850 LPM at suitable Head i/c all services as per manufacturer guidlines/Manual,overhaulingchecking,greasing & necessaryrepairs/replacement ofinternaldefectivepartsetc.asrequiredi/c re-testing &commissioning etc.,completeas required. 26 Reconditioning of the existing main Electric Driven Jockey Pump Set having a discharge upto 180 LPM at suitable head Head i/c checking,greasing andre-fixingthesameaftereffecting necessaryrepairsofinternaldefectiveparts etc.andreplacementofbearingscompleteas reqd. 27 Reconditioning of the Main Electrical panel (for Main Electric pump, Diesel Engine & Jockey pump), i/c dismantling & removing from the existing location,overhauling checking,dehumidifying the same after effecting necessary repairs/replacement of internal defective parts etc. as required i/c re-testing & commissioning etc., complete as required I/c replacement of the following parts:Digital Ammeter Digital VoltmeterSelector switch for local/remote, auto/ mannual off operation:- 4 Nos.Slandered relays & accessories for automatic operation of deisel engine:- 3 Nos.Push button:- 6 Nos.LED:- 6 Nos.Contactor:- 2 Nos.FRLS Copper internal wiring as reqd. 28 B) FIRE ALARM SYSTEMSINTELLIGENT FIRE ALARM SYSTEMSupplying,installation,testingandcommissioningofmicro processor based intelligent addressable mainfirealarm panel, central processingunit with the following loop modules and capable ofsupportingnotlessthan240devices(includingdetectors)and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 + 5% V,50 hz), 48 hrs back-upwith 24voltsealedmaintenancefree batterieswithautomaticcharger.Thepanelshallhavefacilityto connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part ofthescheduleofworkunderSH:PASystem) andshallbe completewithallaccessories.Thepanelshallbecompatiblefor IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.Two Loop Panel 29 Supplying, installation, testing & commissioningof intelligent analog addressablephotothermaldetectorcompletewithmountingbase complete as required. 30 Supplying, installation, testing &commissioning ofaddressable manual call point complete as required. 31 Supplying, installation, testing & commissioningof addressable horn cum strobe complete as required. 32 C) PUBLIC ADDRESS SYSTEMSupplying,installation,testing&commissioningof16zone,voice alarmcontrollerwithUSB,MP3player(including16zonebutton paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. 33 Supplying, installation, testing & commissioning of ceiling/wall mountedloudspeaker,1.5/3/6WattinABSenclosurecompleteas required. 34 Supplying,installation, testing&commissioning ofdigitalaudio amplifier 1000 Watt, 25V rms operating at 240 volt AC supply complete as required. 35 Supplying,installation,testing& commissioningofVoice command keypad 16 zone, with microphone assembly complete as required. 36 CABLING & WIRINGSupplying&layingof2x1.5sqmmfiresurvivalarmouredcable, 600/1000V rated with annealed copper conductor having glass mica firebarriertapecoveredbyanextrudedlayerinsulation and LSZH inner bedding,steelwirearmouring&LSZHoutersheathcompleteas required. 37 D) DISMANTLINGDismantling ofexisting pipes, fittings etc. and other associated in complete shape as per directionof Engg in charge and stacking the same at desired place etc as reqd. 38 DismantlingofoldexistingFirealarmpanel, Smoke Detector,MCP, Hooter, Cable,Wires,PA System, ceiling/wall mounted loud speaker obtained from Golf View & Samridhi Apartment complete as required. 39 E) SH - VI(Credit)CreditofoldexistingFirealarmpanel,Smoke Detector, MCP, Hooter, Cable,Wires,PASystem,ceiling/wallmounted loud speaker, firefighting pipe, fitting and associated accessories obtained Complete as required.

Key Value

Document Fees
Refer document
EMD
INR 490621.0 /-
Tender Value
INR 2.45 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail