}

Tender For Construction Of Components Of Waste To Compost Pit And Semi Mechanised Mrf ( Material Recovery Facility ) At Doloigaon Under Swachh Bharat Mission- U, 2.0 ( Phase - I ), Barpeta-Assam

Urban Development Department has published Tender For Construction Of Components Of Waste To Compost Pit And Semi Mechanised Mrf ( Material Recovery Facility ) At Doloigaon Under Swachh Bharat Mission- U, 2.0 ( Phase - I ). Submission Date for this Tender is 04-07-2025. Excavation Work Tenders in Barpeta Assam. Bidders can get complete Tender details and download the document.




Tender Notice

49649177
Tender For Construction Of Components Of Waste To Compost Pit And Semi Mechanised Mrf ( Material Recovery Facility ) At Doloigaon Under Swachh Bharat Mission- U, 2.0 ( Phase - I )
Tender
Indian
Assam
Barpeta
04-07-2025

Tender Documents

Tender Details

Tender For Construction Of Components Of Waste to Compost Pit and Semi Mechanised MRF ( Material Recovery Facility ) at Doloigaon under Swachh Bharat Mission- U, 2.0 ( PHASE - I )-Compost Pit - Tihu M.B 2 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavatedearth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.All kinds of soil230 mm thick wall115 mm thick wallPlinth Proctection wallpole Pit 3 Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from naturalsources : 6 graded stone aggregate 20 mm nominal sizederived from natural sources) 4 Brick work with common burnt clay modular bricks of class designation7.5 in foundation and plinth in:Cement Mortar 1:4 (1 cement : 4 coarse sand). 5 Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) 6 Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 7 Soling (or subbase) of well burnt soling bricks including filling of interstices and rolling.(Old size bricks, one layer laid onflat.) 8 15 mm cement plaster on the rough side of single or half brick wall ofmix :1:6 (1 cement: 6 fine sand) 9 White washing with lime to give an even shadeNew work (three or more coats 10 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes 11 Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 12 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to anypitch, including fixing with polymer coated J or L hooks, bolts & nuts 8mm dia. G.I. plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.2 mm thick corrugated (2.5 or 4.2 or 6) or step-down (2 or 3 or 6 ) as specified 13 Providing and fixing bolts including nuts and washers complete 14 INTERNAL ELECTRIFICATION IN ALL BUILDINGS 15 PVCsinglecoresheathedcableWiring withcopperconductorcablesInstove enamelledStee l Conduit .One light point or one fan point controlled by one switch with cables 1.5 sq. mm size Group A 16 PVCsinglecoresheathedcableWiring withcopperconductorcablesInstove enamelledStee l Conduit .One light point or one fan point controlled by one switch with cables 1.5 sq. mm size Group C 17 Wiring for light point with 1.5 Sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 No 2.5 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 18 Wiring for light/ power plug with 4 X 4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 19 Supplying and fixing of following sizes of PVCconduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 20 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 75x75x50mm 21 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 147x93x47mm 22 supply and fixing following modular base & cover plate on existing modular metal boxes etc as required. 4/5 module 23 Supply and fixing following modular switch andsocket on the existing modular plate & switchbox including connections but excludingmodular plate etc as required 3 pin 5/6 amp socket outlet 24 Supply and fixing following modular switch andsocket on the existing modular plate & switchbox including connections but excludingmodular plate etc as required Telephone socket outlet 25 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc asrequired 26 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etcas required 27 supply and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required 28 Supply and fixing call bell/ buzzer suitable for D.C/ A.C single phase 230 volts complete as required. 29 Supply and fixing 3 pin, 5 amp. Ceiling rose on the existing junction box/ wooden block including connection etc as required. 30 Supply and fixing brass batten/ angle holder including including connection etc as required 31 Installation, testing and comissioning of ceiling fan, ancluding wiring the down rods of standard length(upto 30 cm) with 1.5sq mm FR PVC insulated, copper conductor single core cable, including providing and fixing phenolic laminated sheet cover on fan box etc as required 32 Installation , testing and commissioning of pre wired,flourescent fitting/compact flourescentfitting of all types, comlete with all accessories and tube etc directly on ceiling/wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc as required. 33 Installation , testing and commissioning of prewired, flourescent fitting/compact flouredcent fitting of all types, comlete with all accessories and tube etc. including supplying and fixing ball and socket arrangement 2no down rods of 20mm dia X 1.6mm thick steel conduit upto 30cm lenth painting and wiring the down rods and connection with 1.5 sq mm FR PVC insulated, copper conductor, single core cable and earthing etc as required. 34 Installation of exhaust fan upto 510 mm sweep in the existing opening including making the hole to suit the size of the above fan making good the damage connection testing commissioning etc as required. 35 Extra for cutting and threading of G.I pipe heavy guage down rod for ceiling fan etc. as required 36 Supply and fixing following way, single poleand neutral, sheet steel, MCB distributionboard, 240 volts, on surface/ recess, completewith tinned copper busbar, neutral busbar,earth bar, din bar, detachable gland plate,interconnections, phosphatized and powderpainted including earthing etc as required. 2way single door 37 Supply and fixing 6 amps to 32 amps rating 240 volts B series miniature circuit breaker suitable for lighting and other loads of following poles in the exsisting MCB DB complete with connection testing and commisssioning etc. as required 6/32 amps, single pole B series 38 Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required 39 Separation room/chamber (10.00m X 3.00m) 40 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) 41 Galvanised wire mesh of average width of aperture 1.4 mm and nominal dia of wire 0.63 mm Back Face, Side & Partition , Front Face 42 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.ISA-40x40x5 - Vertical bar , ISA-25x25x2- Tie bar, MS flat bar 40x5,Front open lid 43 GI sheet 0.8 mm thick confirming to IS 277:1992 at bottom 44 Mild steel plates 2mm thick for front open lid 45 Welding by gas or electric plant including transportation of plant at site etc. complete.For gate opening, Front & back face,Sides and partitions 46 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete 50x37x1.50 mm 47 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :100x10 mm 48 Waste Receiving Platform 49 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth up to 50 m and lift up to 1.5 m, asdirected by Engineer-in- Charge:All kinds of soil. 50 Sand filling under floors or in foundations including watering and consolidation 51 Soling (or subbase) of well burnt soling bricks including filling of interstices and rolling. (Old size brick , one layer laid flat.) 52 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal sizederived from natural sources)

Key Value

Document Fees
INR 1000 /-
EMD
INR 27060.0 /-
Tender Value
INR 13.53 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail