| 1 | Demolishing brick work including stacking of serviceable material and disposal of unserviceable material within 50 mtr lead. In cement mortar |
| 2 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m,including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal ofsurplus excavated soil as directed with in a lead of 50 meter. All kinds of soils |
| 3 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excludingthe cost of centering and shuttering - All work up to plinth level.1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size). |
| 4 | Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CMthick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 5 | Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth levelincluding curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and makinggood the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix |
| 6 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removalof formwork for foundation , footings, strap beam, raft , basesof columns etc. |
| 7 | Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five levelincluding curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and makinggood the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams,suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plainwindows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix |
| 8 | Centering & shuttering with plywood or steel sheets includingstrutting, propping bracing both ways with steel props andremoval of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies,girders, cantilevers, bands, coping bed plates, anchor blocks,sills, chhajjas, lintel, beam, plinth beam etc. |
| 9 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in positionand binding (including cost of binding wire) all complete up to floor five level.(\"Original producers\" who manufacture billet directly from iron ores and roll the bilets to produce steel conforming toIS:1786)Thermo-mechanically Treated bars (Conforming of relevent IScode) |
| 10 | Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurrymixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1: 4 (1 cement : 4 coarse sand)For area of each slab from 2001 to 5000 Sq.Cm |
| 11 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in allshapes and sizes in :Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 12 | Half brick masonry in Superstructure , above plinth level upto floor V level using bricks of designation 75 Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 13 | Providing and fixing stone slabs table rubbed, 15-18 mm thick in Walls, Steps, Pillars, Counters, Jambs, Shelves, Sills etc. laid on 12mm (Av.) thick base of CM 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marbleslab including grinding, rubbing and polishing complete. Keseriaji/ Abu Ambaji (Green Marble)Above 3601 Cm2Slabs |
| 14 | Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenolformal dehyderesin in glue both sides with approved steel fittings complete as per annexure \"A\" :35 mm thick .Decorative teak veneer both side |
| 15 | Providing & fixing door, window, chowkhats and other frames, including antitermite treatment, M.S. flat, hold fasts of size 250 x 40 x 3mm fixed with M.S. bolt 5mm dia 50mm long duly embedded in cement concrete M-15 grade :Sal wood Grade - I |
| 16 | Providing&FixingCommercial Ply as per IS710 : 1976 BWRof approvedmake formakingwardrobe/shelves and otherfurniturewithfevicol&nailscomplete asperapproved by engineer in charge. (i) 18 mm thick |
| 17 | Providing and Fixing Cushion Vinyl/Fully flexible Vinyl Flooring confirming to I.S.-3462 Flooring of approved make with fibre base using rubber base adhesives including rolling with light wooden roller complete : 2.0 mm thick. |
| 18 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concreteblocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with woodenplugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 19 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm thick. |
| 20 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smoothcompleteNew Plastered Surface (three or more coats) |
| 21 | Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an evenshade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respectincluding scaffolding and safety provision New Work |
| 22 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including allscaffolding:Two or more coats on new work including prepartion of basewith primer, putty, lippy etc complete in all respect. |
| 23 | R.R dry stone kharanja under floor |
| 24 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 25 | S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws not exceeding 150mm distance at all heights with all lead and lift with scafolding. |
| 26 | Providing and fixing Square bars or other flat welded to window, ventilatiors etc.. |
| 27 | Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying apriming coat of approved steel primer, welded and bolted including special shaped washers etc. complete. Hot finished welded type tubes. |
| 28 | Supply and installation of Multi Rib Proofing/cladding Sheet Manufacture out of 0.50mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvalume steel (as per 150gsm zinc aluminum coated 550Mpa tuekd strength) confirming to IS: 1397/astm A-792 sheet to have wide pens 30mm high NB at 250 centre and centre width of 1020mm sheets be casted with regular modified polyster system on a continuous with line on centre for face and with a polyster coating respectively sheet shall have proportionality with siphoned plate made to prevent leakage sheet shall be fixed by more of sell drilling lift tapping hot dip zinc coated hox head fasterner of size 12x14x55mm long. The sheet shall be supplied in cost one length and for a minimum up to 12mts with all scaffolding.Add extra for 0.60mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvalume steel sheet in place of 0.50mm thick |
| 29 | Providing and fixing stone slabs table rubbed, 15-18 mm thick in Walls, Steps, Pillars, Counters, Jambs, Shelves, Sills etc.laid on 12mm (Av.) thick base of CM 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement :2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Keseriaji/ Abu Ambaji (Green Marble)Above 3601 Cm2 Slabs |
| 30 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, SillsCounters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab includinggrinding, rubbing and polishing complete Jhunjhunu / Jalore Red/Choclate/Black/Pink Colour) Above 3601 Cm2 Slabs |
| 31 | Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machinepolishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite/Kota Stone Work Full Edge moulding |
| 32 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shadesglazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on abed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of thetile complete (excluding the cost of cement plaster on wallsand pillar). Extra for using size above 200x300mm in glazed tiles |
| 33 | P &F Kitchen & Lab. Sink of approved make with C.I. bracketsduly painted 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor. 1.0 mm thick stainless steel AISI -304 & IS 13983-1994 Kitchen sink of approved make as per Engineer-in-charge with large waste coupling.Overall size (inches)24 x 18 x 8 Bowl size (inches)20x16x8 |
| 34 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brassthreaded fittings i/c fixing the pipe with clamps at 1 metrespacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete asper direction of Engineer in Charge. (Internal work Exposed on wall)25 mm nominal size |
| 35 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)pipes (IS 15778 : 2007 code) having thermal stability for hot& cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings withone step CPVC solvent cement, renching refilling & testing of joints complete as per direction of Engineer in Charge.(External work).25 mm nominal size |
| 36 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2 .) approved quality /make including joining the pipe withsolvent cement rubber ring and lubricant. 75 mm dia. |
| 37 | --do-- 110mm dia. |
| 38 | P & F Pilllar Cocks (IS :8931 : 1993 Mark) of superior quality and approved makeC.P. Pillar cock, Swan-neck with casted spout, 15mm nominalbore. |
| 39 | P& F Sink Cocks of superior quality & approved made : 2.9.1 C.P. Sink cock swinging spout 15mm. |
| 40 | Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation,20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring ,earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr.size 600 x 450mm depth upto 0.5 M Cement cover with frame. |