}

Tender For Request For Bids For Supply, Installation And Commissioning Of Slaughter House Plant As Per Apeda Standard, vihar-Maharashtra

Pune Municipal Corporation has published Tender For Request For Bids For Supply, Installation And Commissioning Of Slaughter House Plant As Per Apeda Standard. Submission Date for this Tender is 18-07-2025. Dismantling Work Tenders in vihar Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

49580723
Tender For Request For Bids For Supply, Installation And Commissioning Of Slaughter House Plant As Per Apeda Standard
Tender
Indian
Maharashtra
Vihar
18-07-2025

Tender Documents

Tender Details

Request For Bids For Supply, Installation And Commissioning Of Slaughter House Plant As Per Apeda Standard - 1 A: CIVIL WORK ITEMS 2 Dismantling the Reinforcement Cement Concrete (R.C.C.) Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete. 3 Dismantling brick masonry in lime or cement mortar and stacking the material as directed with all leads, lifts etc. 4 Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete. 5 Removing ventilators and small windows with frame and stacking the materials with all leads, lifts etc. complete. 6 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete 7 Removing purlins from roof including stacking as directed with all leads , lifts etc. complete. 8 Removing rafters from roof including the materials as directed with all leads , lifts etc. complete. 9 Removing Queen Post truss from roof and stacking the materials as directed with allleads and lifts etc. complete 10 Removing Galvanized Iron (G.I.) or Asbestos Cement (A.C.) sheet roofing including purlins, principal rafters etc. including sorting serviceable and unserviceable materials, stacking the same as and where directed in the compound includingscaffolding etc. complete. 11 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removingtheexcavatedmaterialuptoadistanceof50m.beyondthebuildingareaand stackingandspreadingasdirected,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means 12 Lift upto 1.50 M 13 Excavationforfoundationinhardmurum includingremovingtheexcavatedmaterialupto distanceof50metersbeyondthebuildingareaandstackingandspreadingasdirected, dewatering,preparingthebedforthefoundationandnecessarybackfilling,ramming, wateringincludingshoringandstruttingetc.complete.(Liftupto1.50m)ByMechanical Means 14 Lift upto 1.50 M 15 Excavation for foundation in Hard murum including removing the Cubic Meter (Cu.M) excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m.) By Mechanical Means 16 Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling withavailable earth/murum, ramming ,watering including shoring andstrutting etc. complete. (Lift from 1.5m To 3.0 m.) By Mechanical Means 17 Lift upto 3.0 M 18 Excavation for foundation in Hard-rock by blasting including Cubic Meter (Cu.M) trimming and levelling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the building area including dewatering and back filling with available earth/murum watering, ramming etc. complete. (Lift from 1.5m To 3.0 m) By Mechanical Means 19 Filling in plinth and floors with approved excavated materialsavailable at site in30 cm layers include- ing watering and compaction with plate compactor to required proctor densityetc complete. 20 Filling in plinth and floors with contractorsmaterial/brought from outside and approved by Engineerin charge inlayersof15cm to20cmincludingwateringandcompactionetc. complete. 21 Providingdry trap / granite / quartzitegneiss200 mm thick hardcore metal spread in two layers each of 125mm thick crushed to 100 mm consisting of machine crushed stone metal 65-80mm thick, compactingwith 10MTroller and mechanical powercompactor etc. including murum blindage on surface, watering etc. complete 22 Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surfaceofplinthfillingattherateof5litresofemulsionconcentrateat1.0percentof clorophyrifosperOne Square Metre of surface area covering ten years guarantee on bond paper. 23 ProvidingandlayingCastinsitu/ReadyMixcementconcreteinMix-10 (M-10)oftrap/granite/ quartzite/gneissmetalforfoundationandbeddingincludingbailingoutwater,Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided,finishing with IPSandcuringcomplete,withfullyautomaticmicroprocessor based PLC with Supervisory Control and Data Acquisition (SCADA) enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Crushed sand VSI Grade). 24 1:3:6 ( 1 cement, 3 sand, 6 crushed graded stone aggregate 20 mm and down gauge) 25 Providing andlaying Castinsitu/ReadyMixcement concrete Mix -15 (M-15) oftrap/ granite/quartzite/gneissmetalforcoping to plinthorparapet,mouldedorchamferedasper drawingorasdirectedincludingsteelcentering,plywood/steelformworkcompacting, rougheningthemifspecialfinishistobeprovided,finishingunevenandhoneycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will Numberst be allowed.) With fine aggregate (Crushed sand VSI Grade) 26 ProvidingandlayingCastinsitu/ReadyMixcementconcreteMix-20 (M-20)oftrap/granite/ quartzite/ gneiss metal for Reinforcement Cement Concrete (R.C.C.)slabs andlandingsasper detaileddesigns anddrawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the foed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with Supervisory Control and Data Acquisition (SCADA) enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 27 Providing and laying Reinforcement Cement Concrete (R.C.C.)Mix-25 (M-25) of trap stone metal, as per detailed designs and drawing or as directed by Architect/ Structural Engineer, including shuttering, formwork, compaction , curing, hacking and roughening the surface if special finish is to beprovided. (Excluding reinforcement steel). 28 ProvidingandlayingCastinsitu/ReadyMixcementconcreteMix-25 (M-25)oftrap/granite/quartzite/gneissmetalforReinforcement Cement Concrete (R.C.C.)workinfoundationslike raft,strip foundations,grillage and footings of Reinforcement Cement Concrete (R.C.C.) columns and steel stanchions etc. including bailing out water,Steel centering,formwork,coverblocks,laying/pumping,compactionandcuring roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with Supervisory Control and Data Acquisition (SCADA) enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 29 ProvidingandlayingCastinsitu/ReadyMixcementconcreteMix-25 (M-25)oftrap/granite/quartzite/gneissmetalforReinforcement Cement Concrete (R.C.C.)workinfoundationslike raft,strip foundations,grillage and footings of Reinforcement Cement Concrete (R.C.C.) Plinth beam and steel stanchions etc. including bailing out water,Steel centering,formwork,coverblocks,laying/pumping,compactionandcuring roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with Supervisory Control and Data Acquisition (SCADA) enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 30 ProvidingandlayingCastinsitu/ReadyMixcementconcreteMix-25 (M-25)oftrap/granite /quartzite/gneissmetalforReinforcement Cement Concrete (R.C.C.)columnsasperdetaileddesignsanddrawingsoras directedincludingsteelcentering,formwork,coverblocks,laying/pumping,compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smoothand even surface or roughening if special finish is to be providedand curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with Supervisory Control and Data Acquisition (SCADA) enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 31 ProvidingandlayingCastinsitu/ReadyMixcementconcreteinMix-25 (M-25)oftrap/granite/ quartzite/ gneiss metal for Reinforcement Cement Concrete (R.C.C.) Slab beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping,compaction and roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcementandstructuralsteel).withfullyautomaticmicroprocessorbasedPLCwith Supervisory Control and Data Acquisition (SCADA)enabledreversibleDrumTypemixer/concreteBatchmixplant(Panmixer)etc. complete. With fine aggregate (Crushed sand VSI Grade) 32 ProvidingandlayingCastinsitu/ReadyMixcementconcreteMix-25 (M-25)oftrap/granite/ quartzite/ gneiss metal for Reinforcement Cement Concrete (R.C.C.)slabs andlandingsasper detaileddesigns anddrawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with Supervisory Control and Data Acquisition (SCADA) enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 33 Providing and laying Cast in situ/Ready Mix cement concrete Mix-25 (M-25) of trap/ granite/ quartzite/ gneiss metal for Reinforcement Cement Concrete (R.C.C.) chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting androughening the surface ifspecial finish is to be provided and curing complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbasedPLCwithSupervisory Control and Data Acquisition (SCADA) enabledreversibleDrum Typemixer/concreteBatchmixplant(Panmixer)etc.complete.Withfineaggregate (Crushed sand VSI Grade) 34 ProvidingandlayingCastinsitu/ReadyMixcementconcreteinMix-25 (M-25)oftrap/granite/ quartzite/gneissmetalforReinforcement Cement Concrete (R.C.C.)pardiofrequiredthicknessincludingsteelcentering, formwork, cover blocks, laying/pumping,compacting and roughening them if special finish istobeprovidedandcuringcomplete.(Excludingreinforcementandstructuralsteel).with fullyautomaticmicroprocessorbasedPLCwithSupervisory Control and Data Acquisition (SCADA)enabledreversibleDrumType mixer/concreteBatchmixplant(Panmixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade) 35 Providing and laying Cast in situ/Ready Mix cement concrete Mix-30(M-30) of trap / granite /quartzite/ gneiss metal for Reinforcement Cement Concrete (R.C.C.) work in foundations like raft, strip foundations, grillage and footings of Reinforcement Cement Concrete (R.C.C.) columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be providedand curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with Supervisory Control and Data Acquisition (SCADA) enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 36 Providing and laying Cast in situ/Ready Mix cement concrete in Mix-30 (M-30) of trap/ granite/ quartzite/ gneiss metal for Reinforcement Cement Concrete (R.C.C.) pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with Supervisory Control and Data Acquisition (SCADA) enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)R.A. Unit : 1 / Cubic Metre 37 25.74 Providing and laying Cast in situ/Ready Mix cement concrete Mix-30 (M-30) of trap/ granite / quartzite/ gneiss metal for Reinforcement Cement Concrete (R.C.C.) slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing theformed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with Supervisory Control and Data Acquisition (SCADA) enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 38 Providing and fixing in position Thermo Mechanically Treated (TMT) - FE - 500 bar reinforcement of various diameters for Reinforcement Cement Concrete (R.C.C.)pilecaps,footings,foundations,slabs,beamscolumns,caNumberspies,staircase,newels, chajjas,lintelspardis,copings,fins,archesetc.asperdetaileddesigns,drawingsand schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. 39 ProvidingAutoclavedAeratedConcreteBlockmasonaryof conforming to Indian Standard IS :2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) 40 ProvidingAutoclavedAeratedConcreteBlockmasonaryofconforming to Indian Standard IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech orequivalentinHalfbrickthickwallincludingstrikingjoints,rakingoutjointsand scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) 41 Providing fly ash brick masonry with conventional /Indian Standard I.S. type fly ash bricksin Cement Mortar 1:6 in foundation and plinth includingbailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. 42 Providing fly ash brick masonry with conventional/ Indian Standard I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete 43 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in Cement Mortar.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with Cement Mortar.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixedwithapprovedwaterproofingcompound.Markingfinishedsurfacewithfalse squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for requiredheight,withdripmouldatthejunctionofplasterandparapetandcuringand covering10yearsGuaranteeagainstleakproofnessonCourtfeestamppaperofRs.500/- including ponding test etc. complete. 44 Providing waterproofing in Water Closet (W.C.) and bath including brick bat coba in all position including providingandlaying12mmbeddingincementmortor1:3onverginconcreteslabwith waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba ofrequired thickness in cm 1:5withwaterproofing compound1Kilogram/bag ofcement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years guarantee on requisite stamp paper including curing etc. complete. 45 Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and Reinforcement Cement Concrete (R.C.C.) walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete) 46 Providinginternalcementplaster12mm thickinsinglecoatincementmortar1:3without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete. 47 Providing sand faced plaster externally in cement mortar using approved screened sand, in all positionsincludingbasecoatof15mmthickincementmortar1:4usingwaterproofing compound at 1Kilogramper cement bag curing the same for Numberst less than 2 days and keeping thesurfaceofthebasecoatroughtoreceivethesandfacedtreatment6to8mm thickin cementmortar1:4finishingthesurfacebytakingoutgrainsandcuringforfourteendays scaffolding etc.complete. 48 Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete. 49 Providing internal cement plaster 6mm to 12 mm thick in single coat in cement mortar 1:3with Cement Floating plaster and using waterproofing compound in Cement Mortar. at 1 Kg. Per cement bag , to RCC wall, Raft in all positions including scaffolding, curing, cleaning etc. complete.( including chiken mesh at all concrete joints) 50 Providing, laying and carrying out jointless 3mm thick epoxy screed & 2mm Self-levelling SL 2000 in flooring or coving over the hard wearing, dust free, dryIndian Patent Stone (I. P. S.) surface with materials of approved manufacturer including checking of adequacy of floor to carry work, surface preparation, primer coat of 170 u thickness, screed in 1:6 quartz and 2mm epoxy self levelling epoxy in granular finish each all as per manufacturers specification inclusive of demanded by the Owner/Engineer etc complete.All work should be completed as per manufacturers specification instruction manuals and as approved by the Owner/Engineer. (cement concrete-Flooring will be paid separately). as 6.01a 51 Providing and laying cement concrete flooring 40 mm thick with Mix-15 (M15) cement concrete laid to proper level and slope in alternate bays including compaction, filling joints, marking lines to give the appearance of tiles of 30 cm x 30 cm or other size laid diagonally/ square etc finishing smooth (with extra cement) in any colour as directed and curing etc. complete. With Crushed Sand. 52 Providing and laying Antiskid Ceramic tiles of approved qualityof size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. 53 Providing and laying ceramic tiles having size 30 cm. x 60 cm. confirming to corresponding I.S.for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. 54 Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded Numberssing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. 55 Providing and laying vitrified matt finish tileshaving size 590 mm to 605 mm x to 605 mm of8to10mmthicknessandconfirmingIS.15622-2006(GroupBla)ofapprovedmake, shadeandpatternfordadoandskirtinginrequiredpositionfixedin1:4cementmortar including neat cement float, filling joints, curing and cleaning etc. complete. 56 Providingandfixinggreenmarbleof18to20mmthickfordoorframe/dado/window boxing etc. On Cement Mortar 1:6 including filling joints with polymer base filler Numberssing / moulding the sharp edges wherever necessary, curing,etc. complete. 57 Providing andconstructing granite kitchenplatform withfixing of stainlesssteelsink 600 mm x 450mm size as per detaileddrawing including vertical bothside polishedkadappah stone 25 to 30 mm thick supports with kadappahtop 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two verticalgranitesupports15cmheightandtopgraniteof75x40cmincludingcutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m) 58 Providing and fixing 34 mm thick moulded door shutter consisting of solid core single leaf flush door of 30 mm thickness lipped with 15 mm ( 5mm x 3) thick x 30 mm width on one style and top rail and 10 mm (5mm x 2) thick x 30 mm width on other style and bottom rails with Door Frame of 18mm thick plywood like panneling 450mm in Jams, 450mm at lintel level with 1mm thickness with approved laminate fixing. Theinnerpanelslaminatedwith2mmthicktermiteproof,waterproofandfireresistant mouldedPVC sheet with2,4,6 design in different plainand /or prelim colours on one side after routing the moulded design on flush doors and 2 mm plain and /or pre lam PVC on other side using rubber adhesive on flush door and solvent cement adhesive on the PVC lipping etc. Fixing all fittings such as mortise locks, handles, latches, stoppers etc. asperdirectionofEngineerinchargeandmanufacturersspecificationanddrawingetc. complete. 59 Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two trackswithrectangularpipe having overalldimension63.50x38.10x1.02mm atweight 0.547 Kilogram/One Running Metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm atweight0.695Kilogram/One Running Metre.Topandside track section61.85x31.75x 1.30 mm at weight 0.659 Kilogram/One Running Metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/One Running Metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Runningmetre.AsperdetaileddrawingsandasdirectedbyEngineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With powder coating with box 60 Providing and fixing in position powder coated aluminium louvered windows / ventilator of varioussizeswithpowdercoatingasperdetaileddrawingandspecificationsincluding aluminiumframes80x38mmx1.22mmboxtype,5mmthicksheetglasslouvers,of approved quality etc. complete. 61 Providingandfixingweldedmeshof11gaugewireshavingmeshsize50mmx25mm including M.S Angle frame of size 35 mm x 35 mm x5 mm in position with oil painting 3 coats etc. complete 62 Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness Numberst less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet Numberst less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear) 63 Providingandapplyingprimingcoatonconcrete/masonary/AsbestosCementplastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. 64 Providing and applying Numbersn-toxic, Numbersn-absorbent washable paint of approved color and shade to new surfaces of walls, ceilings, etc., in two coats, including scaffolding and preparing the surfaces, complete. The paint shall be suitable for food processing areas and meet all relevant health and safety standards. The final coat shall be roller finished to give a characteristic texture. 65 Providing and applying two coats of exteriorweather shield paint of approved manufacture andofapprovedcolourtotheplasteredsurfacesincludingcleaning,preparingtheplaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etccomplete 66 Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. 67 Providing structural steel work in trusses, other similar trussed purlins and members with all bracing,gussetplatesetc.asperdetaileddesignsanddrawingsoras directedincluding cutting,fabricating,hoisting,erectingfixinginposition, Makingriveted/bolted/welded connectionandone coat of anticorrosive paint andover it 2 coats of oil painting approved quality and shade etc. complete. 68 Providing andfixing colourcoatedZincalume (R)AZ150(min150gms/Square Metert.totalon each side ) profiled sheets for roofing. The feed material is manufactured out of Numbersminal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength,metallichotdipcoatedwithAluminium-Zincalloy(55%aluminium 43.4%zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with iNumbersrganicpigment).ThepaintshallhaveatotalcoatingthicknessofNumbersminal35um, comprising of Numbersminal 25 um exterior coat on top surface and Numbersminal 10 um reverse coat on back surface. Profile sheet shall have Numbersm. 950-1050 mm effective cover width and Numbersminal 25-30 mm deep ribs with subtle square fluting in the five pan at Numbersminal 180-250 mm center- to-center.The endribshallbedesignedforanti-capillarygroove.andreturnleg.Thefeed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) 69 Providing and fixing Modular false ceiling of 600 x 600 mm center to center and 13 mm thick square mineral fiber board to be fixed on frame work of aluminium sections for suspended falseceilingconsistingofaluminiumT2”x1½”(50mmx40mm)weighing0.39 Kilogram/m at 60 cms center center and fixed with ½” x ½” (15 x 15 mm) flanges weighing 0.19 Kilogram/m suspended on 6 mm dia mild steel rod weighing 0.22 Kilogram/m, fixed on wall and beams including rounding of the edges with aluminium T of 2” x 1 ½” (50 mm x 40 mm) weighing 0.39 Kilogram/m etc. (all aluminium sections shall be aNumbersdized) including all labour, material, lifts etc. complete. 70 Providing and Fixing mat finish stainless steel (of 302 grade ) railing with toppipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing, fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75mmdiameteretc.complete(PriorapprovalofsampleandbrandbyEx.Engineeris necessary before use) 71 Providing and erecting chain link fencing 1.6 M. height with Galvonised Iron (G.I.) chain link of size 50x 50 mm, 8 gauge thick and fixed on vertical Mild Steel (M.S.) Angles of 40 x 40 x 6 mm size, at 1.75 M. c/c with iron bar 16mm dia as hold fast including welding link with angle frame at 30 cm c/c with nuts and bolts and horizontal M.S. Angles at top andbottom of 25 x 25 x 5 mm size andvertical M.S. flat 35 x 5 mm and25 x 5mm horizontal including cross support of 40 x 40 x 6 mm angles both side at every corner or bend embedded in concrete blocks of 1:4:8of size 450 x 450 x 670 mm including 3 coats of oil painting etc. complete. 72 Insulated sandwich Panel Ceiling Panel : 120mm Thick Panels both side Pre-quoted-2 Wall and Partition Panel: 120mm Thick Panel both side Flashing: Water Proof, Tamper Proof, Corrosion Resistant, Durable Coating As Req. U Clamps Angle, Ridge: Water Proof, Tamper Proof, Corrosion Resistant, Durable Coating As Req. Silicon: Water Proof, Tamper Proof, Corrosion Resistant, Durable Coating As Req. Anchor Fashner : Waterroof, Tamper Proof, Corrosion Resistant, Durable Coating. including Main Chamber Doors 2Numberss, Steel structure support for the Blast Freezer, Manual Conveyor Line SS 304 with All Accessories , Accessories , etc. complete 73 Supply & installation interior work including False celling, tables, chairs, Gypsum Partion, toughened Glass door with fixtures etc. Completed as per instruction of site incharge. 74 Supply & Installation rain water harvesting system including collection of rain water from roof top & Discharge in bore hole with the closed type RWH etc. completed 75 Supply & Installation of Security Cabin in fiber reinforced polymer (FRP) Material on the concrete top etc. Completed 76 Supply & Installation of Electrical Lift for material / Caracas for Up & Down (Ground Floor to First Floor) with all the fixture, etc. Completed 77 Transportation of material obtained from excavation including soil, rubble,bricks,Reinforcement Cement Concrete RCC concrete, kerb stones, steel railing, iron pipes, channels etc. Obtained from excavation, dismantling, loading in a Truck of minimum 5 Cubic Meter (CuM) capacity or designed capacity and transporting within the municipal limits or any designated place, unloading, stacking or spreading of material etc. complete. 78 Geotechnical investigation-Providing detailed geological reports of proposed site by maintaining geotechnical investigation of structure stratification collecting soil, rock and ground water samples for laboratory tests to arrive the foundation design parameters . Rock properties such as type of rock, jointing fractures, etc. complete with suggestion about the site foundation and remedies 79 Providing and fixing white european type wall-hung, Size 360mm x 360mm x 575 mm with flush valvehaving flow rate up to 6.0 Litr/Minute of Jaguar/Cera/Hindware /Perryware or equivalentmakeincluding PVC soil pipe, vent pipe upto outside face of wall, 100mm diaPVCplug bend inlet pipe all fittings,cutting & making good walls, floors etc as directed by Engineer in charge.( Make shall conform to manufacturers Green product and shall got approved from the Engineer In Charge.) 80 Providing and fixingwall hung white wash basin of size550 x 400 x 195 mm withpillar cockhaving flow rate up to 6.0 Litr/Minute,C.P.Angular stop cock long threadof Jaguar/Cera/Hindware /Perryware or equivalentmake, including SS bottal trap of approved make etc complete as directed by Engineer in charge.( Make shall conform to manufacturers Green product and shall got approved from the Engineer In Charge.) 81 Providing and fixing superior type modiguard mirror 5 mm thick, on a backing of BWP ply 12 mm thick, pre painted with one coat of primer and 2 coats of synthetic enamel paint with teak wood moulding 20 X 20 mm only at top fixedsecurely to wall with adequate no. and size of cp. mirror screws and anchor fasteners complete. 82 1000 x 1000 mm 83 Sensor Operated Smart flow Hand Dryers,Components and Material One-piece cover in ABS thermoplastic. Fixed to the base by two screws. Thermoplastic PP + talcumbase. Class B brush motor incorporating a safety thermal cut off. PPUL9-V0 helicoidal fan wheel. Heating element incorporates a safety thermal cut-off. Electronic infrared detection sensor with an adjustable detection distance (15-25cm). Installation:Inclusive of all accessories. 84 Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. 85 Providing and fixing in position soap dish ( Redlay make ) complete. 86 Providing and fixing health faucet ( Jaguar Make ) to all European water closets including one angular valve ( Jaguar no.053 ) with all accessories complete. 87 Providing and fixing white glazed urinal with Pressmatic auto closing valvehaving flow rate up to 4.0 Litr/Minute of Jaguar/Cera/Hindware /Perryware or equivalentmake with P.V.C. waste pipewith fittingarrangementetc.complete as directed by Engineer in charge.( Make shall conform to manufacturers Green product and shall got approved from the Engineer In Charge.) 88 Providingandfixingmachinecutmirrorpolished18mm to20mm thicktelephoneblack granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc.complete . Both side polish (urinal Partion) 89 Providing and fixing on walls/ ceiling/ floor 15 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 90 Providing and fixing on walls/ ceiling/ floor 25 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 91 Providing and fixing on walls/ ceiling/ floor 32 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 92 Providing and fixing on walls/ ceiling/ floor 40 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 93 Providing and fixing on walls/ ceiling/ floor 50 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 94 Providing and erecting ready made storage tanks of Sintex or approved manufacturer and required size including connecting necessary supply lines, delivery lines, wash water line and with manhole cover at top of not less than 450 mm clear dia, with locking arrangement complete as per drawing and as directed and instructed by Engineer/Owner. 95 Tank of 1000 liters capacity. 96 Tank of 2000 liters capacity. 97 Water troughs for sheep/goats 98 Providing and fixing in position unplasticized ploy venyl chloride (uPVC ultra voilet rays stabilised of below diameter rain water / Soil & waste pipe required diameter conforming to IS 13592 :1992 Including necessary fittings such as uPVC grating, bends with door, uPVC clamps over mild steel bracket m.s. flat of 40mm wide and 3mm thick on walls, horse shoes at bottom, rubber ring and making connections water tight with solvent cement including making hites in masonary concrete, redoing the same in cement mortar 1:3 curing, testing etc. complete. Spec. As directed by Engineer In charge. 99 40 mm (SWR - HP for Wash Basin Outlet) 100 50 mm (SWR - A Type for Antisiphonage) 101 75 mm (SWR - B Type for Waste water) 102 110mm (SWR - B type for Soil water) 103 ProvidingandconstructingBrickMasonryInspectionChamber90cmx45cmx90cm including1:4:8cementconcretefoundation1:2:4cementconcretechannelshalfround G.S.W.pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete. 104 ProvidingandconstructingBrickMasonryInspectionChamber90cmx45cmx90cm including1:4:8cementconcretefoundation1:2:4cementconcretechannelshalfround G.S.W.pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete. 105 Providing and fixing 8 cm rigid PVC Nahani trap including PVC grating ,bend, connecting piece of UPVCpipe up to the outside face ofwall ,making the gooddamagedsurface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) 106 Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. 107 Providing and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. 108 Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. 109 Providing and fixing hume pipe septic tank 900mm diameter with vent pipe and cap including necessary (including excavation and laying) 110 Providing and fixing 50 mm. dia. medium class G.I.pipe gate with wicket gate of approved drawing with all fixtures and fittings in two leaves with strong hold fast embedded in c.c. block at top and bottom with locking arrangement including cutting, bending, making holes and with one coat of primer etc. complete. 111 Preparation of Lawn including ground preparation upto a depth of 0.45M; disposal of rejected soil/rubbish/debris if any upto a lead of 50-75M;manuring and consolidation of surface; final levelling and drainage of the ground; procuring of healthy grown CALCUTTA DOOB grass and laying it in the soil medium fully covering the ground; weeding; scraping and raking; top dressing and maturing; urea and pesticides; and watering; cutting & maintaining the lawn in good shape all complete 112 Providing and fixing Ductile iron Man Hole Covers/ Strom Water Grating and Grating with frame of Various sizes, weight and types and load bearing capacity as per EN-124, equivalent NECO with prior approval of concerned Superitending Engineer. 113 Providing in position 110mm dia. PVC pipe sleeves of 6Kg/cm2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam upto 0.5 mtrs length. All pipes shall beaccurately cut to the required sizes, laid as per drawing, kept in the position while concreting, and burrs removed before laying. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Rate shall be inclusive of removal of sleeves before water proofing or grouting. For all floors / all levels / all heights. 114 Providing and fixing i.e. Fabrication and errection of- M.S. Inserts - Plates, Hooks, Pipe sleeves, Holding down bolts, Nosing angle, etc completed Sleeve Pipe (G.I PIPE) 150mm Dia 115 Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flat stringers and steps of 18 mm dia. mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60cm x 30cm x 30cm and painting the ladder complete. (Anti Corrosive Paint) 116 Royalty charges: For Other Minerals 117 Transportation of material obtained from excavation including soil, rubble,bricks,Reinforcement Cement Concrete RCC concrete, kerb stones, steel railing, iron pipes, channels etc. Obtained from excavation, dismantling, loading in a Truck of minimum 5 Cubic Meter (CuM) capacity or designed capacity and transporting within the municipal limits or any designated place, unloading, stacking or spreading of material etc. complete. 118 Geotechnical investigation-Providing detailed geological reports of proposed site by maintaining geotechnical investigation of structure stratification collecting soil, rock and ground water samples for laboratory tests to arrive the foundation design parameters . Rock properties such as type of rock, jointing fractures, etc. complete with suggestion about the site foundation and remedies 119 Material Testing 120 CEMENT: Standard Consistancy, Fineness, Specific Gravity, Setting Time ( Initial & Final ), Compressive Strength, Soundness. 121 AGGREGATE: Water Absorption, Specific Gravity,Impact Value, Crushing Value. 122 CONCRETE: Compressive Strength OF Cement Concrete. Cube (Set of 3 cubes). 123 STEEL BAR TESTING: Upto 16 mm (Set of 3 Bars) (Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.) 124 STEEL BAR TESTING: Above 16 mm (Set of 3 Bars) (Tensile strength, %, Elongation, Yield Stress, Weight-Per Meter, Bend / Rebend Test, Proof Stress.) 125 HOLLOW / SOLID /AAC BLOCKS: Density Test . (Set of 3 Blocks ), Compressive Strength. (Set of 3 Blocks ),Water Absorption Test ( Set of 3 Blocks ) 126 B: ELECTRICAL WORKS ITEMS 127 Supplying and erecting rolled steel joist (girder) pole 152 x 152 mm (37.1 kg/m) with provided base plate in provided foundation as per specification no. OH-PL/RSJ 128 Making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles) 129 Supplying and erecting distribution class, 22 kV thyrite type lightning arresters with nut bolts, on provided MS channel as per specification no. OH-INS/LA 130 Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. 131 Supplying and erecting guarding lace for HT OH line with 8SWG G.l. wire to protect the HT OH line with binding wire of 20SWG G.l. wire for 75mm section on either side. 132 Supplying and erecting 11 kV outdoor type gang operated air break, triple pole switch 400 A capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of C class G.l. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp. 133 Supplying and erecting, 11 kV outdoor type drop out fuse with insulatorcomplete with fuse holders, fuse barrel with metal fitting, fuse elementmounted on M.S. channel with working current of 15A capacity completeerected on provided cross arm. 134 Supplying and erecting porcelain post type insulator with nut bolts suitable for 11kV line, complete as per specification no. OH-INS/PST 135 Supplying and erecting porcelain disc type insulator 45KN with necessaryhardware suitable for 11kV line, complete as per specification no. OH-INS/DI 136 Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/10 SWG, G.l. stay rod 20 mm x 1.8 m length and pole clamps duly erected in provided cement concrete foundation. 137 Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay). 138 Supplying and erecting ACSR conductor of size 6/1-2.11 mm complete. (squirrel) (85kg/km) as per specification no. OHCON/ACSR 139 Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 300 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HTFor round wire armouring increase rate Note -2)For 11 kV (E) by 28% For 11 kV(UE), 22 kV, 33kV (E)/(UE) by 31% 140 Providing and erecting Heat shrinkable straight through joint kit for 11 kV(UE)/22 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT 141 Providing and erecting Heat shrinkable indoor termination kit for 11 kV(UE)/ 22 kV ( E ) XLPE HT cable 3x240 to 400 sq. mm. with necessary material as per specification no. CB-JT/HT 142 Providing and erecting Heat shrinkable outdoor termination kit for 11 kV (UE)/ 22 kV ( E ) XLPE HT cable 3x240 to 400 sq. mm. with necessary material as per specification no. CB-JT/HT 143 Supplying & erectingcast iron cable indicatorplate buried along with route of cable for PVC / XLPE armoured cableas per specification No. CB-CIP 144 HT EQUIPMENT 145 Supplying, installing, testing and commissioning 11 kV 630A, indoor type ring main unit with 1 VCB & 2 LBS with internal arc compliance completeerected on provided CC foundation/MS channels/trench, etc., as per specification no SW-HTS / RMU 146 Supplying, installing, testing & commissioning 3 phase,11/0.433 kV, 50 Hz., 250 kVA, Mineral oil immersed and naturally cooled outdoor type, Copper wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise should not Exceed 45℃ by thermometer in oil and 50℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5%, having 7 number of tap positions ,with standard accessories complete with test certificate with losses below 980 Watts at 50% load, 2930 Watts at 100% load as per IS:1180 (part 1) : 2014, with necessary permissions of Electrical Inspector, as per specification no SS- TRNSL. 147 Making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm.thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete. 148 DG SET 149 Supplying, erecting, testing and commissioning of diesel generating set with alternator of 100 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 17.4 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 230 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG 150 AMF PANEL 151 Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 125 kVA up to 140 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. 152 Supplying, erecting, testing & commissioning of outdoor type 6 Way L.T. feeder pillar shall suitable for 3 ph/4w/50Hz; 415V AC system. The F.P. should be adequately ventilated waterproof & shall have slanting roof top. The hinged front double door & back double shall be provided with two lock key in duplicate shall be supplied for each pillar for locking & unlocking the front door The F.P. should be fabricated out of 14 SWG M.S sheet it shall be fixed on MS angle frame of 65 x 65 x 6 mm pedestal 10 SWG MS sheet with shall be fixed on the pedestal. Outer dimension of 6 way feeder pillar, height should be 1700 mm ,width 1080 mm, depth 450 mm approx.(Excluding MS angle frame) bottom skirt shall be painted with black colours. The feeder pillar shall have name plate of MSEDCL & caution board shall be fixed on front side & back side. Louvers should have MS wire mesh form inside. Aluminium busbars of feeder pillar having size 60 x 10 mm for phase, 50 x 5 mm for neutral & 40 x 10 mm for outgoing. The busbar shall be fixed on insulators (as per IS) by maintaining proper clearence. Asbestos cement sheet must have thickness of minimum 4 mm. Earthing terminals should be provided from both sides in the form of GI threaded studs. Provided foundation base should have cocreting ratio 1:4:8. Porcelain HRC fuse base of 600 amp.-3 No. & 400 amps.HRC fuses (15 Nos) should be provided at incoming so as isolate entire bus. The design of pillar shall be such as to accommodate following sizes of cables. i)Incoming - 6 cables of 3 1/2 core, 400/300 sq mm. PVC armoured cables ii)Outgoing-2 cables of 3 1/2 core, 240/185/120 sq mm suitable flange type glands & proper size of lugs to match with the size of the cables shall be provided Test certificate Showing the necessary test. Carried out as per IS, like dimensional check, Insulation resistance test, shall be submitted for our final approval before dispatch of material complete. (RA Item) (2018-19) 153 Providing & erecting floor/wall mounting, MCCB panel board, with door,suitable for four pole incoming 400A, 8 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no. SW-SWR/MCCBPB. (Excluding MCCBs) 154 Providing & erecting floor/wall mounting, MCCB panel board, with door,suitable for four pole incoming 400A, 12 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no. SW-SWR/MCCBPB. (Excluding MCCBs) 155 Providing & erecting incoming and outgoing cable alleys suitable for MCCBpanel board with door, 250A incoming and 12 way outgoing or 400A incoming and 6/8 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB. 156 Providing & erecting incoming and outgoing cable alleys suitable for MCCBpanel board with door, 400A incoming and 12 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB. 157 Supplying and erecting 30 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating , APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC 158 Supplying and erecting 75 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating , APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC 159 Supplying and erecting ON LOAD four pole automatic transfer switch, 415V, 400A, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 . 160 Supplying and erecting ON LOAD four pole automatic transfer switch, 415V, 315A, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 . 161 Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuitbreaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 162 Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuitbreaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 163 Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCBNote: 1)For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.2)In case of specialised application, MCCB used at incomer level shall be microprocessor based with LSIG (overload, short circuit, instantaneous, earth fault) inbuilt protection and shall have door mounted display to ensure close door operation; increase the rate by 20%. 164 Providing & erecting 4 Pole MCCB, 415 V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCBNote: 1)For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.2)In case of specialised application, MCCB used at incomer level shall be microprocessor based with LSIG (overload, short circuit, instantaneous, earth fault) inbuilt protection and shall have door mounted display to ensure close door operation; increase the rate by 20%. 165 Providing & erecting 4 Pole MCCB, 415 V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCBNote: 1)For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.2)In case of specialised application, MCCB used at incomer level shall be microprocessor based with LSIG (overload, short circuit, instantaneous, earth fault) inbuilt protection and shall have door mounted display to ensure close door operation; increase the rate by 20%. 166 Providing & erecting 4 Pole MCCB, 415 V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCBNote: 1)For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.2)In case of specialised application, MCCB used at incomer level shall be microprocessor based with LSIG (overload, short circuit, instantaneous, earth fault) inbuilt protection and shall have door mounted display to ensure close door operation; increase the rate by 20%. 167 LT Cable 168 Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (Round) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Basic Rate:(242+242x27%)=307.34+307.34x5%=322.77=323Note:1) For round wire armouring increase rates by 27%.5) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % 169 Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (Round) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALNote:1) For round wire armouring increase rates by 27%.5) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % 170 Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (Round) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALNote:1) For round wire armouring increase rates by 27%.5) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % 171 Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (Round) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALNote:1) For round wire armouring increase rates by 27%.5) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % 172 DISTRIBUTION BOARDS 173 Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB 174 Supplying, fixing and commissioning 2 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO (DB Incomer) 175 Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB (For Lighting) 176 Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB (For Power) 177 POINT WIRING 178 Point wiring for light/bell/exhaust fan in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WGPW/SW. 179 Point wiring for ceiling fan in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW 180 Point wiring for independent plug in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E ) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW 181 Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No :WGPW / CW 182 Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. 183 Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. 184 Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.(For 16A Power Socket) 185 Supplying and erecting modular type bell-push with indicator 2 modules 6A /10A, duly erected on provided plate and box with wiring connections complete. 186 Supplying and erecting modular type buzzer 220 / 250V, duly erected on provided plate and box with wiring connections complete. 187 Supplying and erecting LED square / circular Max. 18 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 188 Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. 189 Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W)of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speedregulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF 190 Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation. 191 Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete. 192 Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete. 193 Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete. 194 Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW 195 Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-11 as per specification No. WG-TW 196 Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC 197 MAINS AND SUB-MAINS 198 Supplying and erecting mains with 2x2.5+1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BWBase Rate: 62 + Half Rate of 2x1.5 wire is 20 = 82Note:Rates of earth wire shall be calculated as one half rate of mains of bunch of two wire 199 Supplying and erecting mains with 2x4+1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.as per specification No: WG-MA/BWBase Rate: 89 + Half Rate of 2x2.5 wire is 31 = 120Note:Rates of earth wire shall be calculated as one half rate of mains of bunch of two wire 200 METER ROOM 201 Providing & erecting 3 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in providedenclosure/panel as per specification no. SW-SWR/MCCB 202 Supplying and erecting static energy Trivector meter 440 V 50 Hz. 20-100A ISI mark meter AC 3 phase 4 wires LCD/LED display (Measuring and display Trivector, V, I, kW, PF, Hz, Last month history of kWh & MD in kW) with special features like TOD, Tamper logging, Optical Communication Port & Display in absence of Power complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested for class 1.0 accuracy by electric supply company. 203 Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V 300A having 40mm (Width) X 5 mm (Thickness), with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CPBB 204 Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V 630A having 50mm (Width) X 10 mm (Thickness), with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CPBB 205 Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCBNote: For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB. 206 Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm. 1400 RPM complete erected in position as per specification no. FG-FN/EXF 207 Point wiring for light/fan/bell in 20 mm FRLS grade HMS PVC conduitwith 1.5 sq.mm (2+1E) FRLSH grade copper wire with flush type switch and required accessories as per specification No: WG-PW/SW 208 LIFT SHAFT LIGH & POWER 209 Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. 210 Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. 211 Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected. 212 Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. 213 COMMON LIGHT 214 Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB 215 Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 216 Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 217 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 218 Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW 219 Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. 220 EARTHING AND PROTECTION 221 Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI 222 Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. 223 Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. 224 Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete. 225 Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP 226 Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP. 227 CABLE TRAY 228 Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm width & 20 mm height complete with necessary hardware 229 Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 500 mm width & 20 mm height complete with necessary hardware. 230 PUMP & PANEL 231 Supplying and erecting minimum Three & above star rated submersible pump set of 5.625 KW/7.5 HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 100 to 400 LPM discharge at 132 to 27 m head & discharge & delivery pipe of Size-50 mm diameter with a necessary H type clamps as per specification No. WP-SMP(Domestic Pump) 232 Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.C. Submersible/centrifugal pump set up to 7.5 HP - 10 H.P. consisting of DOL starter having relay range 13-21 AMP,S.P.P., Combined ammeter/voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc.(Domestic & Flushing pump) 233 SAFETY EQUIPMENT 234 Supplying and fixingPVC synthetic elastomerelectrically insulating matwith class C insulation conforming to IS: 15652 – 2006 tested having 3mm thickness up to 33 kV 235 Providingpair ofdulytestedrubber hand glovesas per IS :47705suitable forworking up to 22 kV supply complete. 236 Supplying standardfirst aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes) 237 Supplying and fixingPVC synthetic elastomerelectrically insulating matwith class A insulation conforming to IS: 15652 – 2006having 2 mm thickness up to 3.3 kV 238 Providing printed instruction chart for treating persons suffering from electric shock, printedinEnglish & Marathi and duly laminated complete. 239 Supplying, installing, testing and commissioning of 3 kWp ON-GRID Solar PV System / Plant consisting solar PV poly crystalline panel (335 Wp X 09 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate,canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card / chip for 5 years including net charges for RMS system, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per specification no. ESD-RT-ONG 240 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 241 Supplying & erecting G.I. pipe ‘A’ class 40 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE 242 Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL 243 Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT 244 Making cement concrete foundation including excavation ( 45 x 45 x 120 ) cm deep in 1:3:6 cement concrete, 20 to 25 mm stone metal, (45 x 45 x 45) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (for 6 m pole) 245 Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. 246 Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW 247 Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP 248 Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. 249 Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation. 250 C: FIREFIGHTING WORKS ITEMS 251 Hydrant Installation 252 Supply, Installation, Testing, Balancing and Commissioning of the following Fire Fighting equipment and materialsin accordance withSpecificationsand inclusive of all taxes, duties, loading, unloading, octroi, transportation, scaffolding, insurance and all other statutory payments. 253 Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drillingand welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. 254 Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP 255 Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP. 256 Pipes (FF-PP). Supplying and erecting G.I. pipe ‘C’ class ERW 20 mm dia with necessary fittings complete as per specification no. FF-PPR.A. Unit : 1 / Metre 257 Pipes (FF-PP). 1Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PPR.A. Unit : 1 / Metre 258 Supplying and erecting G.I. pipe ‘C’ class ERW 32 mm dia with necessary fittings complete as per specification no. CW-PLB/GB. 259 Supplying and erecting G.I. pipe ‘C’ class ERW 40 mm dia with necessary fittings complete as per specification no. CW-PLB/GB. 260 Pipes (FF-PP). Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PPR.A. Unit : 1 / Metre 261 Pipes (FF-PP). Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PPR.A. Unit : 1 / Metre 262 Pipes (FF-PP). Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PPR.A. Unit : 1 / Metre 263 Pipes (FF-PP) .Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PPR.A. Unit : 1 / Metre 264 Pipes (FF-PP) .Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PPR.A. Unit : 1 / Metre 265 Pipes (FF-PP) .Supplying and erecting G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PPR.A. Unit : 1 / Metre 266 Pipes (FF-PP). Providing coating of bitumen paint & 4mm thick wrapping for underground 100 mm ring main of fire fighting system.R.A. Unit : 1 / Metre 267 Pipes (FF-PP) .Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.R.A. Unit : 1 / Metre 268 Making trench in soft soil having 0.75 m depth and minimum 0.3 m width for laying provided cables up to voltage level of 1.1kV complete As per specification No. CW-EXN-CTR 269 Valves (FF-FV) .Sluice Valve. Supplying and erecting 150 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF VL/SVR.A. Unit : 1 / Each (For Ring Main) 270 Providing and making second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in foundation sand plinth of inner walls /in plinth external walls including bailing out water manually, striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. 271 Valves (FF-FV) .Butterfly Valves (BFV). Supplying and erecting 75/80 mm dia.cast iron double flange butterfly valve of size complete with PN16 pressure rating, as perspecification no. FF-VL/BFVR.A. Unit : 1 / Each 272 Valves (FF-FV) .Butterfly Valves (BFV). Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as perspecification no. FF-VL/BFVR.A. Unit : 1 / Each 273 Valves (FF-FV) .Butterfly Valves (BFV). Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as perspecification no. FF-VL/BFVR.A. Unit : 1 / Each 274 Valves (FF-FV) .Butterfly Valves (BFV). Supplying and erecting 200 mm dia.cast iron double flange butterfly valve of size complete with PN16 pressure rating, as perspecification no. FF-VL/BFVR.A. Unit : 1 / Each 275 Valves (FF-FV) .Gate / Wheel Valves (GV). Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF VL/GVR.A. Unit : 1 / Each 276 Valves (FF-FV) .Non Return Valve (NRV). Supplying and erecting 75/80 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRVR.A. Unit : 1 / Each 277 Valves (FF-FV) .Non Return Valve (NRV). Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no.FF-VL/NRVR.A. Unit : 1 / Each 278 Valves (FF-FV) .Non Return Valve (NRV). Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no.FF-VL/NRVR.A. Unit : 1 / Each 279 Valves (FF-FV) .Non Return Valve (NRV). Supplying and erecting 200 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no.FF-VL/NRVR.A. Unit : 1 / Each 280 Valves (FF-FV) .End Line Strainer (positive suction) (ELS). Supplying and erecting 75/80 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as perspecification no. FF-VL/ELSR.A. Unit : 1 / Each 281 Valves (FF-FV) .End Line Strainer (positive suction) (ELS). Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as perspecification no. FF-VL/ELSR.A. Unit : 1 / Each 282 Valves (FF-FV) .End Line Strainer (positive suction) (ELS). Supplying and erecting 150 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as perspecification no. FF-VL/ELSR.A. Unit : 1 / Each 283 Valves (FF-FV) .End Line Strainer (positive suction) (ELS). Supplying and erecting 200 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as perspecification no. FF-VL/ELSR.A. Unit : 1 / Each 284 Fire Fighting Accessories (FF-FFA). Air Cushion Tank (Air Vessel) (ACT). Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no.FF-FFA/ACTR.A. Unit : 1 / Each 285 13.08-h-13 Fire Fighting Accessories (FF-FFA). Air Release Valve (ARV). Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARVR.A. Unit : 1 / Each 286 Fire Fighting Accessories (FF-FFA).Pressure Switch(PS) .Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc completeas per specification no. FF-FFA/PSR.A. Unit : 1 / Each 287 Fire Fighting Accessories (FF-FFA).Pressure Gauge (PG). Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as perspecification no. FF-FFA/PGR.A. Unit : 1 / Each 288 Valves (FF-FV) .Hydrant Valves (HV). Supplying and erecting gun metal double outlet hydrant valve fitted with necessary accessories complete as per specification no. FF VL/HVR.A. Unit : 1 / Each 289 Fire Fighting Accessories (FF-FFA). Orifice Plate(OP). Supplying and erecting brass orifice plate having 6 mm. thickness, 160 mm outer dia with required diameter of inner hole at every double outlet hydrant valve as per specification no. FF-FFA/OPR.A. Unit : 1 / Each 290 Fire Fighting Accessories (FF-FFA).Hose Reel with Drum (HR). Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as perspecification no. FF-FFA/HVR.A. Unit : 1 / Each 291 Fire Fighting Accessories (FF-FFA). MS / CRCA Boxes (BOX) . Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25x 4 mm. having front doors with viewing glass (8x6) and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour(Code 538 of IS 5)R.A. Unit : 1 / Each 292 Fire Fighting Accessories (FF-FFA). Hose Pipes. Supplying and erecting 63mmdia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRLR.A. Unit : 1 / Each 293 Fire Fighting Accessories (FF-FFA).Nozzles (NZ). Supplying and erecting gun metal branch pipe of 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specification no. FF- FFA/NZR.A. Unit : 1 / Each 294 13.07-g-34 Valves (FF-FV) .Hydrant Valves (HV). Supplying and erecting gun metal single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF VL/HVR.A. Unit : 1 / Each 295 Fire Fighting Accessories (FF-FFA). Orifice Plate(OP). Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OPR.A. Unit : 1 / Each 296 Fire Fighting Accessories (FF-FFA). MS / CRCA Boxes (BOX) . Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25x 4 mm. having front doors with viewing glass (8x6) and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour(Code 538 of IS 5)R.A. Unit : 1 / Each 297 Fire Fighting Accessories (FF-FFA). Fire Brigade Connection (FBC). Supplying and erecting 150 mm dia fire brigade header suitable for supplyingwater in fire tank complete as per specification no. FF-FA/FBCR.A. Unit : 1 / Each 298 Fire Fighting Accessories (FF-FFA).Siamese Connection (SMC). Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FF-FA/FMCR.A. Unit : 1 / Each 299 Providing round bottom FIRE Bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook. 300 Providing floor mounting Stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint. 301 Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. 302 Supplying and erecting ABC powder type fire extinguisher as per IS : 13849/15683 of 6 kg capacity with necessary clamp for erection on wall. 303 Fire Sealant System (FF-FRM) . Supplying and erecting fire resistant mortar (20kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings of all kinds of cables, pipes and cable support system in steel,aluminium and plastic profiles ( except hollow core conductors). The residual openings shall be closed with filler, as per specification no FF-FRM.R.A. Unit : 1 / JOB 304 Total for Hydrant Installation 305 Fire Pump Installation 306 Main FirePumpSupplying, installation, testing and commissioning of main fire pump (MFP /EP) suitable for water discharge of 1400 to 1600 LPM at 60 to 50 m headdriven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 22kW or ofsuitable kW capacity for manual/automatic operation and consisting of following:(a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronousspeed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted typewith Class-F insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump setwith accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, asper specification no. FF-MFP/SSC/EP 307 Jocky PumpSupplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 70 to 50 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP 308 Diesel PumpSupplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 1600 to 1800 LPM at 70 to 50 m head driven by 45 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting offollowing :(a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine, exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer,instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump setwith engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP 309 Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connectionshaving switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specifications the capacity of electric motor driven pump are as followsa. Main fire pump(MFP) having capacity of 22kW 1no (1 working)b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby,alternate run per start in auto mode) comprises of the following features & switchgears:1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating.2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFUs, starters & outgoing terminals with necessaryaccessories like stainless steel nut bolts with spring washers for connections,mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable rating. 310 D: PLANT AND MACHINERY ITEMS 311 Slaugher Line (As per tender specification) 312 Cold Room (As per tender specification) 313 Blood Processing unit (As per tender specification) 314 Biogas unit (As per tender specification) 315 ETP (As per tender specification) 316 Laboratory Equipment (As per tender specification) 317 Reefer Van (As per tender specification)

Key Value

Document Fees
INR 17879 /-
EMD
INR 500000.0 /-
Tender Value
INR 9.77 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail