}

Tender For Miscellaneous Civil Works For Server Room And Dps At Hwp(T), tuticorin-Tamil Nadu

Heavey Water Board has published Tender For Miscellaneous Civil Works For Server Room And Dps At Hwp(T). Submission Date for this Tender is 26-06-2025. Dismantling Work Tenders in tuticorin Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

49523108
Corrigendum : Tender For Miscellaneous Civil Works For Server Room And Dps At Hwp(T)
Tender
Indian
Tamil Nadu
Tuticorin
26-06-2025

Tender Details

Tender For Miscellaneous Civil Works For Server Room And Dps At Hwp(T); 1 Dismantling alumimium glazed partition with door, stacking of serviceable material and disposal of un-serviceable materialwithin 100 mts lead including scaffolding if required etc.., all complete at all heights as per drawings, specfications and as directed by the Engineer. 2 Dismantling false floor panel of size 600x600x32 mm medium grade including allied frame work, stacking of serviceable material and disposal of un-serviceable materialwithin 100 mts lead etc.., all complete as per drawings, specfications and as directed by the Engineer. 3 Providing and fixing removable raised/false access flooring300 mm finished floor height with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting ofa) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer diameter with two GI Check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc., all complete as per the architectural drawings, as specified and as directed by the Engineer-in-chargec) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones The top and bottom plates of Steel Gauges top 0.6 mm and bottom 0.7 mm fused spot welded together welds along each flange). The panel should be Corroresist (minimum 64 welds in each dome and 20 epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate B55is filled with Pyrogrip noncombustible Portland cementitious core mixed with lightweight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product. 4 Fixing removable raised/false access flooring300 mm finished floor height with system and its components for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting ofa) Fixing at required spacing to form modular frame work, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer diameter with two GI Check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc., all complete as per the architectural drawings, as specified and as directed by the Engineer-in-chargec) Fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones The top and bottom plates of Steel Gauges top 0.6 mm and bottom 0.7 mm fused spot welded together welds along each flange). The panel should be Corroresist (minimum 64 welds in each dome and 20 epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate B55is filled with Pyrogrip noncombustible Portland cementitious core mixed with lightweight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product.Note: All materials including frames dismantled vide item no.02 shall be used and additional frames if any required shall be scope of contractor. 5 Providing and fixing gypsum board tiled false ceilingof 8 mm thick,595x595 mm size, dew drop model, PVC laminated on face side and secured with MPL film on rear side of approved brand and shade in true horizantal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams /sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x32 mm made from 0.30 mm thick (minimum) sheet,spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross T oflength 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be inetrlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., mainT runners to be suspended from ceiling using GI slotted cleats of size 27x37x25x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mmGI adjustables rods / support L section with galvanised butterfly level clips of size 85x30x.8 mm spaced at 1200 mm center to centre along main T ,bottom exposed width of 24 mm of all T-sections shall be pre painted with polyester paintetc.., all complete at all heights as per specifications, drawings and as directed by Engineer. 6 Providing and fixing aluminium work for doors and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS 733 and IS 1285,fixing with dash fasteners ofrequired diameter and size ,including necessary filling up the gaps at the junctions i.e. at top,bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth ,rust free straight, mitred,and joined mechanically wherever required including cleat angle,Aluminium snap beading for glazing/paneling, CP brass /Stainless Steel screws,scaffolding etc..,all complete at all heights as per drawings, specificatoins and as directed by the Engineer.6.1). For fixed Portion with powder coated Aluminium sections( minimum thickness of powder coating 50 micron) 7 For shutters of doorwith powder coated Aluminium sections( minimum thickness of powder coating 50 micron) including providing and fixing hinges/pivots and fixtures wherever required including the cost of door handles,stoppers,EPDM rubber/neoprene gasket required. 8 Providing and fixing 12 mm thick pre-laminated particle board flat pressed three layer or graded wood particle board with decorative laminations on both sides conforming to IS 12823 grade I type II in panneling fixed in aluminium doors and partition frames with CP brass /Stainless Steel screws etc.all complete at all heights as per drawings ,specifications and as directed by Engineer. 9 Providing and fixing5 mm thick float glass including garware brand frosted / sun control film panes in aluminium doors and partitions with EPDM rubber/neoprene gasket etc.., allcomplete at all levels as perdrawings, specifications and as directed by Engineer . 10 Providing and fixing door fittings of approved brand and model conforming to relevant IS specificationall complete as per specifications and as directed by Engineer.9.1).Bright finished brass 100 mm mortice latch 6 levers without pair of handles for Aluminium doors. 11 Hydraulic door closer for Aluminum doors 12 Double action hydraulic floor spring for Aluminium doors. 13 Providing garware brand frosted / sun control film in glass panes of windows including removal of existing worn out film, cleaning, preparing the surface of panes suit to sun control filming etc.., allcomplete at all levels as perdrawings , specifications and as directed by Engineer. 14 Providing, fabricating, transporting, erecting and fixing in position structural steel members using MS square tube of size 40 mm (medium duty) af approved brand including cutting, grinding, welding, providing two or more coats of chlorinated rubber paint of approved quality / shade over a coat of primer including scaffolding etc., all complete at all levels as per the drawings, specifications and as directed by the Engineer. 15 Providing and laying 2 mm thick homogeneous Vinyl flooring / skirting of approved brand and shade on cement concrete floor using suitable adhesive including surface preparation, trimming / cutting, pressing uniformly for perfect fixing and cleaning etc.., all complete at all heights as per drawings,specfications and as directed by the Engineer. 16 Removing white wash by scrapping and sand papering manually, preparing the surface smooth including neccessary repairs to scratches, scaffolding, cleaning etc., all completeat all levelsas per drawings, specifications and as directed by the Engineer. 17 Providing and applying Birla wall care putty of average thickness1 mmover a coat of water thinnable interior cement primer of M/s Asian brandto give an even shade over the prepared surface of walls including scaffolding etc., all completeat all levelsas per drawings, specifications and asdirected by theEngineer. 18 Providing and applying two or more coats ofAsian interior gradeacrylic emulsion (ROYALE) of approved colour and shade onsurfaces of walls over a coat of water thinnable interior cement primer of M/s Asian brandto given an even shade including removing white or colour wash by scraping and sand papering and preparing the surface smooth including necessary repairs to scratches, scaffolding, cleaning etc., all completeat all levelsas per drawings, specifications and asdirected by theEngineer.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 20-06-2025 Date Extension Date 26-06-2025

Key Value

Document Fees
Refer document
EMD
INR 25680.0 /-
Tender Value
INR 12.84 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail