Tender For Thottackad Devaswom in Kottayam group - Urgent Rewiring to the temple, stage, Nadapanthal, Devaswom Office, Thanthrimadam-- 1 Dismantling and removing and carefully stacking the existing damaged wiring.Engaged Wire man 2 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm orconcealed S PVC insulated stranded single core suitably and with 1.00sq.mm FRLS copper conductor cable 650V grade, including providing switch board main and continuous earthing with No. 14 SWG bare copper, required quantity of copper earth socket, brass bolt and nut crimping/soldering etc. complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete.All the terminations in the switch boards and DB’s shall be thinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc. as required. (RoHS compliant modular accessories).Single control light points with 6A, plate ceiling rose – medium point 3 Do..do..Single control light points with 6A, plate ceiling rose – shortpoint 4 Do..do..Single control light points without ceiling rose – medium point 5 Do..do..Single control light points without ceiling rose – shortpoint 6 Do..do..Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator - Medium Point 7 Do..do...Combined plug point with 6A,5pin plug socket controlled by in the same switch board 8 Do..do...Independent Plug - Medium Point 9 Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required 1200 mm 1X20W LED Lamp with box type fixture 10 Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture 11 Supplying and fixing suitable size GI box with modular plate and cover in Front on surface or in recess, including providing and fixing 6 pin 5/6- & 15/16-amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 12 Supplying and fixing of Angle/ straight batten holder with 200mm PVC shade, 12W LED bulb fixing on and giving connection. 13 Supply and fixing50W LED bulb 14 Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 15 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door 16 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Double door 17 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 8 way, Double door 18 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps 19 Do do 63 A 20 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 21 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps 22 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 23 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 24 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire 25 Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding. resistance type regular, wiring the down rod with 16/0.0.20m PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 1200mm sweep 5 star rated ceiling fan complete with 300mm down rod, canopies, shackles and blades and resistance type regulator working on 230V/240V single phase A/C. 26 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 27 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 25 sq mm 28 Do do 2 core 10 sqmm 29 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages, colour washing etc.as required.4 core 25 sq mm with factory made clamp 30 Do do 2 core 10 sqmm 31 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4X 25 sq. mm (28mm) 32 Do do 2x10 sqmm (19 mm) 33 Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required 34 Supply and drawing bare earthing conductors of the following sizes along with wiring/cables and giving connection as required.3.15 mm copper conductor (10 SWG) 35 Do do 2.65 mm copper conductor (12 SWG) 36 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. 3.15 mm (10 SWG) 37 Do do 2.65 mm (12 swg) 38 Supply and drawing the following sizes of multi-core PVC insulated &FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm 39 Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. 40 Fabrication supply and installation of dust vermin proof floor mounding thermoplastic meter box of following sizes suitable for fixing KSEB meter, fuse units, CT etc hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment knock out for cable entry exit 600*300*214mm 41 Supply and providing 100A KIT KAT fuse unit complete with all accessories including connections 42 Supplying and fixing following rating, 100A, 2 Way neutral links mounted on DMC/SMC base including drilling holes in cubicle panel, making connections, etc.