}

Tender For Proposed Office Of E.E (Amisp) Near Call Center 1912 At Kesa House, Kesco, Kanpur. - Civil Work: 2 Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm , kanpur-Uttar Pradesh

Kanpur Electricity Supply Co Limited has published Tender For Proposed Office Of E.E (Amisp) Near Call Center 1912 At Kesa House, Kesco, Kanpur. - Civil Work: 2 Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm . Submission Date for this Tender is 26-05-2025. Dismantling Work Tenders in kanpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

49243776
Tender For Proposed Office Of E.E (Amisp) Near Call Center 1912 At Kesa House, Kesco, Kanpur. - Civil Work: 2 Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm
Tender
Indian
Uttar Pradesh
Kanpur
26-05-2025

Tender Documents

Tender Details

Tender For Proposed Office Of E.E (Amisp) Near Call Center 1912 At Kesa House, Kesco, Kanpur. - Civil work: 2 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm (CSI 15.23.1) 3 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.(CSI15.2.1) 4 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below .(CSI 15.12.1) 5 Repairs to plaster with cement mortar 1:4 (1cement: 4 coarse sand) of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.(CSI14.1.2) 6 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (CSI4.1.2) 7 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand):(CSI6.4.2) 8 12 mm cement plaster of mix :1:6 (1 cement: 6 course sand) external plastic are for height upto 10m from ground level in less otherwise stated.(CSI13.4.2) 9 Providing and laying Vitrified tiles in different sizes of 600x600 mm(thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).(CSI 11.47.2) 10 Supply and fixing brass polished hydraulic door closure of approved make & quality its fixing and adjustment with the help of screws, nuts and bolts including supply of all labour, T & P etc. required for proper completion of the work. (OLD CSI No. 8.57) 11 Providing and fixing false ceiling at all heights with integral densifiedr Armstrong false ceiling tiles of Size 595x595 x12 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as perBS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6 SUB HEAD : 26- NEW TECHNOLOGIES AND MATERIALS 1632 mm reveal profilewhite/black),comprising of main-T runners of size 15x42 mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in- Charge. 26.23.1 With 12 mm thick Armstrong MiniralFobre Sound Absorbing Sheet. (CSI No. 28.30) 12 Applying BIRLA PUTTY or equivalent putty on previousaly bila putty smoothen surface over one cost of water base cement primer of ICI or equivalent brand for smoothining and leveling of the surface as per requirement and direction of E/I including cost of all material , labour and T&P required for proper completion of work.(OLD CSI No.13.21) 13 twocoat oil bound distemper on oldwork includingsupply of all materials,labour and T&P etc. required for propercompletion of the work. (OLD CSI No. 13.09+13.1) 14 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.(CSI 13.80) 15 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre.(CSI13.41.1) 16 Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit concealed in wall, GP Box, piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect as per direction of E/I. (PWD131-C) 17 Wiring point for plug with 1 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit conceled in wall with 1.5 sq. mm. FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit on surface, piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect as per direction of E/I. (PWD134-C) 18 Wiring point for fan /fresh air fan (light duty exhaust fan)with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cablein PVC conduit conceled in wall with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect as per direction of E/I. (PWD123-C) 19 Supply and fixing of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. (PWD1139) 20 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door(CSI NO. 28.16) 21 Supply and Fixing of 3 blade ceiling fan 1200 mm of Havells or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge.(OLD CSI No. 28.39) 22 S/R of regulator for ceiling fan of GEC or equivalent make including cost of all labour material, T&P etc. required for proper completion of the work. ( CSI22.60b) 23 Supply and wiring of submain with two number 4 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia PVC conduit on surface, with one number 2.5 sq. mm. multistrand copper drawn in conduit complete in all respect. (PWD216-C) 24 Supply and fixing ofRecess mounting round 15 to 18 watt led down lighter having Powder coated die cast aluminium housing body with heat sink and diffuser/reflector and driver setofcomplete in all respect.(PWD -1403 CATAAA ) 25 S&F of 6 Amp to 32 Amp. MCB (10 KA) C Curve. (PWD C.S.I. No. 1002-B) 26 Supply & instalation of AC COPER PIPE. (NSI) 27 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.(CSI15.60) 28 Engaging of Oneno Beldar for misc. work such like shifting of Almirah,Furniture etc.as per required of site (CSI NO. 1.2+10%CP)

Key Value

Document Fees
INR 1180 /-
EMD
INR 10000.0 /-
Tender Value
INR 9.67 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail