Tender For Repair And Maintenance Work In P.G. Hostel, Rca - 1 Dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meters lead: Of area 3 square meter and below. 2 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : In cement mortar. 3 Dismantling stone slab/ terrazo chip flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meters lead. 4 Dismantlingprecastconcreteorstoneslabsinwallpartitionsetc.includingstackingwithin50 meter lead: Thickness up to 40mm. 5 Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. 6 Making the opening inmasonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground. For door/windows/clerestory windows 7 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge : 1: 3: 6 or richer mix. 8 Demolishing R.B. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 9 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 10 Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge 11 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils 12 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level : M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 13 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in : Cement Mortar 1:6 ( 1-Cement : 6-Sand). 14 Random Rubble stone masonry with hard stone in superstructure aboveplinth level and upto five levelabove 30cm. thick walls in : Cement Mortar 1:6 ( 1-Cement : 6-Sand). 15 Add extra for Random Rubble stone masonry with hard stone in : Square or Rectangular pillars 16 Structural steel work riveted,bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: 17 Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 18 Extra if square,rectangular hollow tubelarsections are used or grill made by flats only 19 Providing and fixing horizontal chajja of Red/ White sand stone 40 mm thick and upto 80 cm projection in cement mortar 1:4 (1 cement : 4 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 20 Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand) 21 Half brick masonry in Superstructure , above plinth level upto floor Vlevelusing bricks of designation 75 : Cement mortar 1 : 4 (1 cement : 4 coarse sand) 22 Supplying and fixing in walls machine cut and polished stone shelves, tands andin CM 1:3 with machine cut edges : Sand or other approved stone 50mm thick. 23 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete : Jhunjhunu / Jalore (Red/Choclate/Black/Pink Colour) Above 3601 Cm2 Slabs 24 Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge : Granite/Kota Stone Work, Full Edge moulding 25 P&F 1st quality standard White, gray, Ivory, fume red brown, light green ,light blue and other light shades glazed tiles of ISI marked ( IS : 13753 ) of size 300 mm. x 200 mm.in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in white cement mixed with pigment to match the shade of tile complete (Excluding the cost of cement plaster on walls and pillars)Extraforusingsize above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finishedtiles in place of 300mm x 300mm size. 26 P and F 1st quality MAT finished ceramic tiles size 300x300mm confirming to IS : 13753 colour such as white, grey ,ivory, fume red brown, light green, light blue and other light shades in floor, steps, pillars etc. laid on a bed on net cement slurry including nicely finished joints using water proof joint filler powder ( Unitile or Roffee make ) and finished with flush pointing in white cement mixed with pigment to matched the shade of tile complete ( including the cost of cement mortar bed 1:4) Extraforusingsize above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finishedtiles in place of 300mm x 300mm size. 27 Providing and laying damp-proof course with cement concrete grade M-150 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as per specification : 50mm thick. 28 Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 20mm thick . 29 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 25 mm thick 30 Renewing glass panes,with putty and nails wherever necessary : Float glass panes of thickness 4 mm 31 Labour charges for repair to door / window without using any material such as applying randha (finishing) tightening of bolts & screw etc. 32 Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Windows side hung /Ventilators top or centre hung (openable) 33 Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. 34 Providing and fixing Square bars or other flat welded to window, ventilatiors etc. 35 Dismantlingroofingincludingridges,hips,valleysandraftersetc.andstackingthewithin 50 meter lead of : G.I. Sheet. 36 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces)excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required : 0.63 mm thick with zinc coating not less than 275 gm/m2 37 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 38 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete : New Plastered Surface (three or more coats) 39 P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete : size600 mm X 600mm 40 Repair to damaged RCC slabs, beams and columns etc for strengthening with cement mortar 1 : 2 in following steps :- (i) Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried. (ii) Applying Epoxy primer on the exposed steel bars.(iii) Applying Epoxy hardener and resin mix (as per manufectureds specification) on concrete and steel bars with brush. (iv) Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface and allow it to dry for one day.(v) Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete.(vi) Cure the plastered surface for 15 days, All work including scaffolding etc. complete in all respect. 41 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: Newwork(twoormorecoats)overandincludingscrappingandprimingcoatwithcement primer. 42 Finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding :New work (Two or more coats applied @ 3.84 kg/10 sqm). 43 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on new work 44 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade :One or more coats on old work 45 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade :Two or more coats on new work 46 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : One or more coats on old work 47 Labourchargesforremovingandrefixingofurinals(alltype&sizes)includingall necessary fittings. 48 P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete : Flat Back (small) size 456x355x265mm. 49 P & F C.P. brass Urinal Spreader for stall urinal of approved make : 50 Removing and re-fixing of wash hand basin including all necessary fittings. 51 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall) 25 mm nominal size 52 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall) 40 mm nominal size 53 Making connection of G.I. distribution branch with G.I. main including all fittings , up to 25 mm. dia. 54 Providingand fixing Ball cock [IS :1703 mark] withrodandPVC ball complete Brass wt. Not less than 300 gm,15mm. 55 P&F C.P.Inlet connection[ Angles / Valves ] superior quality of approved make, for wash basin, Gyser etc.,C.P. Inlet connection15mm. Brass[ IS : 8931 marked] 56 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: Brass 400 gm,15mm nominal bore. 57 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: C.P. Brass bib cock,15mm nominal bore. 58 P& F waste Pipe with all fitting : P.V.C with PVC nut 32 mm 59 P& F waste Coulping with fittings of approved quality /make: C.P Brass 32 mm dia 60 P&F 15mm dia connection pipe of approved quality/ make P.V.C. pipe with C.P.brass nuts upto length 600mm 61 Providing and fixingfull way valve [IS : 778 mark] or wheel valve ofapproved make, gunmetal 25 mm. nominal bore 62 Providingandfixingrigid PVC pipe [IS:4985 mark] class II [4 Kg/cm2] appproved quality/make including jointing the pipe with solvent cement , rubber ring & lubricant, 110mm. dia. 63 Providingandfixingrigid PVC pipe fittings [IS:4985 mark]appproved quality/make including jointing the pipe with solvent cement , rubber ring & lubricant, 110mmdia. 64 [A] Coupler ( Socket ) 65 [B]Plain Tee 66 [C]Door Tee 67 [D]Bend 450 68 [E]Bend 87.50 69 [F]Plain floor trap 70 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathedflexiblecopperearthconductor1.1kVgrade(IS:694)in recessed ISI marked MMS (IS:9537 P.III) virgin materialPVC conduit & its ISI maeked (IS:3419 1988)accessories,round tiles,1.2mm thick Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal/ Surface Moulded virgin material 10AModularswitch,Modular face platewithgridplate,3pin ceilingrose /holder /3way Connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 71 (a) S.P. (up to 3 mtr.) 72 (b) M.P. (up to 6 mtr.) 73 (c ) L.P. (up to 10 mtr.) 74 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FRPVCinsulatedunsheathedflexiblecopperconductor1.1kVgrade and1.5sq.mmnominalsizeFRPVCinsulatedunsheathedflexible copper earth conductor 1.1 kV grade(IS:694) on surfaceISI marked ( IS:14927 P - II ) virgin materialUPVC Trunking & its accessories, Hot Dipped GalvanizedModular box of 1.2 mm thickwith earth terminal/ SurfaceMouldedvirginmaterial UPVCModularBox, modular10A switch, 3/5 pin6 Amodular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR :On board 75 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III)PVCconduitalongwith ISImarked(IS:3419-1988)accessoriesas required in recess including cuttingthewall,coveringconduitand making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR : 25 mm 76 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductorasperPWDspecificationforelectricalWorkswithISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should bemadefrom 99.90%puritycopper,class5strandinginacc.to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization,insulationPVCtypeA/C/D,flameretardantasperIS 10810-53,betteramperageratingasperIS:3961part5, inexisting surfaceorrecessedPVC/MS conduit/casingcapping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required.OEMMusthaveitsowninhouseNABLlabsetupforall testingfacilitiesforwires.Foradditionaltechnicalparametersof product / work refer Annexure A attached with this BSR 77 (a) 2 x 1.5 sq.mm 78 (b) 2 x 2.5 sq. mm + 1x1.5sqmm 79 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of loadand siterequirement)4KVimpulsewithstandvoltage,ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947- 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 asperIEC, minimumphaseterminationcapacityof35sq.mm., conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000upto20Aratingand10,000upto63A,5000for80A& above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR : Single pole MCB (With B/C curve tripping Characteristics)6 A to 32 A rating 80 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular boxof1.2mmthickwithearthingterminal/connectoronsurfaceorin recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16amp.socketoutlet(IS:1293)makingconnection,testing,etc.as required.Forspecificationof WiringaccessoriesreferChapter E-07 related item & For additional technical parameters of product / work refer Annexure A attached with this BSR