Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work inexcavation IN ALL TYPES OF SOILS bymanual means overareas (exceeding 30 cm in depth, 1.5 m in width as well as 10sqm on plan)inculding disposalof excavated earth up to50 m and lift upto 1.5m with all lead and lift including shoring, shuttering & dewatering (if required) with cost of all Labour, Labour cess ,Hire & Running charges of thewater pumps, Sundries, T & P required for the work complete as directed by the Engineer- in- charge. |
| 2 | ADMINISTRATIVE |
| 3 | ACADEMIC BLOCK |
| 4 | GIRLS HOSTEL |
| 5 | SINGLE QUARTER |
| 6 | FAMILY QUARTER |
| 7 | Supplying & Filling foundation trenches , plinth & ditches withclean course river sand well watered and rammed inlayers not exceeding23 c.m.indepthwith all lead and lift including cost, conveyance, loading, unloading,stacking,royalties and alltaxes of sand,cost & conveyance of water, cost of all Labour,labour cess,T&P required for the work etc. complete in all respect as directed by the Engineer- in -charge. |
| 8 | ADMINISTRATIVE |
| 9 | ACADEMIC BLOCK |
| 10 | GIRLS HOSTEL |
| 11 | SINGLE QUARTER |
| 12 | FAMILY QUARTER |
| 13 | Back filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m. |
| 14 | ADMINISTRATIVE |
| 15 | ACADEMIC BLOCK |
| 16 | GIRLS HOSTEL |
| 17 | SINGLE QUARTER |
| 18 | FAMILY QUARTER |
| 19 | Disposal of surplus excavted materials by mechanical means from the work side etc. complete. upto 5km. Lead |
| 20 | ADMINISTRATIVE |
| 21 | ACADEMIC BLOCK |
| 22 | GIRLS HOSTEL |
| 23 | SINGLE QUARTER |
| 24 | FAMILY QUARTER |
| 25 | Providing and laying Plain cement concrete of proportion(1:3:6) in foundation and floors(i.e. below the base course of the flooring) using cement, 40mm. Size crusher broken H.G.Metal and screened and washed sharp river sand for mortar of approved quality and from approved quarry inclduign hoisting, lowering and laying concrete to the required level, ramming,watering and curing etc. completek to required levels, laid in layers not exceeding 15cm thick in each layer including cost, conveyance, loading, unloading,royalities and taxes of all materials, cost of all labour,T&P required for the work including shoring,shuttering anddewatering(if required) including hire and running chargesof water pump required for the work etc. complete in all respect as directed by the Engineer-in-charge. |
| 26 | ADMINISTRATIVE |
| 27 | ACADEMIC BLOCK |
| 28 | GIRLS HOSTEL |
| 29 | SINGLE QUARTER |
| 30 | FAMILY QUARTER |
| 31 | Providing and laying in position ready mixed M-25 grade concrete having compressive strength at 28 days testnot less than 300 kg/ sq.cmfor reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , including the cost of centering, shuttering finishing and excluding reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, and hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,Labour cessand T&P required for the work improve workability without impairing strength and durability as per direction of the Engineer - in - charge. |
| 32 | Foundation |
| 33 | Footing |
| 34 | ADMINISTRATIVE |
| 35 | ACADEMIC BLOCK |
| 36 | GIRLS HOSTEL |
| 37 | SINGLE QUARTER |
| 38 | FAMILY QUARTER |
| 39 | Rcc Column |
| 40 | ADMINISTRATIVE |
| 41 | ACADEMIC BLOCK |
| 42 | GIRLS HOSTEL |
| 43 | SINGLE QUARTER |
| 44 | FAMILY QUARTER |
| 45 | Plinth Beam |
| 46 | ADMINISTRATIVE |
| 47 | ACADEMIC BLOCK |
| 48 | GIRLS HOSTEL |
| 49 | SINGLE QUARTER |
| 50 | FAMILY QUARTER |
| 51 | Ground floor |
| 52 | Rcc Column |
| 53 | ADMINISTRATIVE |
| 54 | ACADEMIC BLOCK |
| 55 | GIRLS HOSTEL |
| 56 | SINGLE QUARTER |
| 57 | FAMILY QUARTER |
| 58 | RCC Roof Beam |
| 59 | ADMINISTRATIVE |
| 60 | ACADEMIC BLOCK |
| 61 | GIRLS HOSTEL |
| 62 | SINGLE QUARTER |
| 63 | FAMILY QUARTER |
| 64 | RCC Roof Slab |
| 65 | ADMINISTRATIVE |
| 66 | ACADEMIC BLOCK |
| 67 | GIRLS HOSTEL |
| 68 | SINGLE QUARTER |
| 69 | FAMILY QUARTER |
| 70 | RCC in Roof slab (Double stage shuttering) |
| 71 | ACADEMIC BLOCK |
| 72 | RCC in Stair case |
| 73 | ACADEMIC BLOCK |
| 74 | GIRLS HOSTEL |
| 75 | SINGLE QUARTER |
| 76 | FAMILY QUARTER |
| 77 | RCC Lintel |
| 78 | ADMINISTRATIVE |
| 79 | ACADEMIC BLOCK |
| 80 | GIRLS HOSTEL |
| 81 | SINGLE QUARTER |
| 82 | FAMILY QUARTER |
| 83 | RCC in Sill |
| 84 | ADMINISTRATIVE |
| 85 | ACADEMIC BLOCK |
| 86 | GIRLS HOSTEL |
| 87 | SINGLE QUARTER |
| 88 | FAMILY QUARTER |
| 89 | RCC Chajja |
| 90 | ADMINISTRATIVE |
| 91 | ACADEMIC BLOCK |
| 92 | GIRLS HOSTEL |
| 93 | SINGLE QUARTER |
| 94 | FAMILY QUARTER |
| 95 | RCC in Platform slab |
| 96 | ADMINISTRATIVE |
| 97 | ACADEMIC BLOCK |
| 98 | GIRLS HOSTEL |
| 99 | First floor |
| 100 | Rcc Column |
| 101 | ACADEMIC BLOCK |
| 102 | GIRLS HOSTEL |
| 103 | SINGLE QUARTER |
| 104 | FAMILY QUARTER |
| 105 | RCC Roof Beam |
| 106 | ACADEMIC BLOCK |
| 107 | GIRLS HOSTEL |
| 108 | SINGLE QUARTER |
| 109 | FAMILY QUARTER |
| 110 | RCC Roof Slab |
| 111 | ACADEMIC BLOCK |
| 112 | GIRLS HOSTEL |
| 113 | SINGLE QUARTER |
| 114 | FAMILY QUARTER |
| 115 | RCC in Stair case |
| 116 | ACADEMIC BLOCK |
| 117 | GIRLS HOSTEL |
| 118 | FAMILY QUARTER |
| 119 | RCC Lintel |
| 120 | ACADEMIC BLOCK |
| 121 | GIRLS HOSTEL |
| 122 | SINGLE QUARTER |
| 123 | FAMILY QUARTER |
| 124 | RCC in Sill |
| 125 | ACADEMIC BLOCK |
| 126 | GIRLS HOSTEL |
| 127 | SINGLE QUARTER |
| 128 | FAMILY QUARTER |
| 129 | RCC Chajja |
| 130 | ACADEMIC BLOCK |
| 131 | GIRLS HOSTEL |
| 132 | SINGLE QUARTER |
| 133 | FAMILY QUARTER |
| 134 | RCC Platform slab |
| 135 | ACADEMIC BLOCK |
| 136 | GIRLS HOSTEL |
| 137 | Terace floor |
| 138 | Rcc Column |
| 139 | ACADEMIC BLOCK |
| 140 | GIRLS HOSTEL |
| 141 | SINGLE QUARTER |
| 142 | FAMILY QUARTER |
| 143 | RCC Roof Beam |
| 144 | ACADEMIC BLOCK |
| 145 | GIRLS HOSTEL |
| 146 | FAMILY QUARTER |
| 147 | RCC Roof Slab |
| 148 | ACADEMIC BLOCK |
| 149 | GIRLS HOSTEL |
| 150 | SINGLE QUARTER |
| 151 | FAMILY QUARTER |
| 152 | RCC Lintel |
| 153 | ACADEMIC BLOCK |
| 154 | GIRLS HOSTEL |
| 155 | FAMILY QUARTER |
| 156 | RCC in Sill |
| 157 | ACADEMIC BLOCK |
| 158 | GIRLS HOSTEL |
| 159 | FAMILY QUARTER |
| 160 | RCC Chajja |
| 161 | ACADEMIC BLOCK |
| 162 | GIRLS HOSTEL |
| 163 | FAMILY QUARTER |
| 164 | Cutting,straightening coiled or bent up HYSD/TMT Reinfocement Bars welding or jointing if necessary ,bending, binding,tying the grills as required for R.C.C. works,providing Fan Hooks where necessary and hoising,lowering and placing the same tin proper position according to the approved eesigns and drawings in all floors including cost, conveyance, loading, unloading and taxes or HYSD/TMT Reinforcement Bars and Binding wieres of 18 to 20 gauge required for the work cost of all labour,T&P and scaffolding complete in all respect as directed by the Engineer-in-charge(Payment will be made according to the actual/proper weight of HYSD/TMT Reinforcement Bars and Binding wires consumed in the particular work only) |
| 165 | Foundation |
| 166 | ADMINISTRATIVE |
| 167 | ACADEMIC BLOCK |
| 168 | GIRLS HOSTEL |
| 169 | SINGLE QUARTER |
| 170 | FAMILY QUARTER |
| 171 | Ground floor |
| 172 | ADMINISTRATIVE |
| 173 | ACADEMIC BLOCK |
| 174 | GIRLS HOSTEL |
| 175 | SINGLE QUARTER |
| 176 | FAMILY QUARTER |
| 177 | First floor |
| 178 | ACADEMIC BLOCK |
| 179 | GIRLS HOSTEL |
| 180 | SINGLE QUARTER |
| 181 | FAMILY QUARTER |
| 182 | Terace floor |
| 183 | ACADEMIC BLOCK |
| 184 | GIRLS HOSTEL |
| 185 | SINGLE QUARTER |
| 186 | FAMILY QUARTER |
| 187 | Fly AshBrickMasonry in cement mortar of mix (1:6)using Fly Ash bricks of size 25c.m x 12 c.m x 8 c.m in Super structure having crushing strength not less than 75 kg per square c.m. withcement andscreened &washed sharp sand for mortar after immersing thebricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties , alltaxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 188 | Foundation |
| 189 | ADMINISTRATIVE |
| 190 | ACADEMIC BLOCK |
| 191 | GIRLS HOSTEL |
| 192 | SINGLE QUARTER |
| 193 | FAMILY QUARTER |
| 194 | Fly AshBrickMasonry in cement mortar of mix (1:6)using Fly Ash bricks of size 25c.m x 12 c.m x 8 c.m in Super structure having crushing strength not less than 75 kg per square c.m. withcement andscreened &washed sharp sand for mortar after immersing thebricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties , alltaxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. (A/R 2006, Pg-71, item no-3) |
| 195 | Ground floor |
| 196 | ADMINISTRATIVE |
| 197 | ACADEMIC BLOCK |
| 198 | GIRLS HOSTEL |
| 199 | SINGLE QUARTER |
| 200 | FAMILY QUARTER |
| 201 | First floor |
| 202 | ADMINISTRATIVE |
| 203 | ACADEMIC BLOCK |
| 204 | GIRLS HOSTEL |
| 205 | SINGLE QUARTER |
| 206 | FAMILY QUARTER |
| 207 | Terace floor |
| 208 | ACADEMIC BLOCK |
| 209 | GIRLS HOSTEL |
| 210 | FAMILY QUARTER |
| 211 | Providing 12mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary) including watering and curing,rounding of corners etc. complete with cost, conveyance, loading, unloading, royalities and taxes of all materials,cost of all labour,T&P, and scaffolding required for the work etc. as directed by the Engineer-in-charge. (Outer side) |
| 212 | Ground floor |
| 213 | ADMINISTRATIVE |
| 214 | ACADEMIC BLOCK |
| 215 | GIRLS HOSTEL |
| 216 | SINGLE QUARTER |
| 217 | FAMILY QUARTER |
| 218 | First floor |
| 219 | ADMINISTRATIVE |
| 220 | ACADEMIC BLOCK |
| 221 | GIRLS HOSTEL |
| 222 | SINGLE QUARTER |
| 223 | FAMILY QUARTER |
| 224 | Terace floor |
| 225 | ACADEMIC BLOCK |
| 226 | GIRLS HOSTEL |
| 227 | FAMILY QUARTER |
| 228 | Providing 16mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary)including watering and curing,rounding of corners etc. complete with cost,conveyance,loading, unloading,royalities and taxes of all materials,cost of all labour,T&P and scaffolding required for the work etc. as directed by the Engineer-in-charge. (Inside PLastering) |
| 229 | Ground floor |
| 230 | ADMINISTRATIVE |
| 231 | ACADEMIC BLOCK |
| 232 | GIRLS HOSTEL |
| 233 | SINGLE QUARTER |
| 234 | FAMILY QUARTER |
| 235 | First floor |
| 236 | ADMINISTRATIVE |
| 237 | ACADEMIC BLOCK |
| 238 | GIRLS HOSTEL |
| 239 | SINGLE QUARTER |
| 240 | FAMILY QUARTER |
| 241 | Terace floor |
| 242 | ACADEMIC BLOCK |
| 243 | GIRLS HOSTEL |
| 244 | FAMILY QUARTER |
| 245 | Providing6 mm thick cement plaster in cement mortar of mix (1:4)at all height using screened& washed sharpriver sandformortar with approved quality of cement tothe ceilingofthe Roof Slab, Staircase,Beams, Columns,Landings, Railings,Chajja ,Fins ,Walls ,Jallyand Shelves etc. including roughening, scraping, chiseling, cleaning, closed deep chipping with slurry treatment and finished smooth to allR.C.C. Surface including cost, conveyance, loading, unloading, royalties ,stacking and alltaxes , cost of all Labour,Labour cess ,Sundries, T&P, Scaffolding, Watering,Curing etc. complete in all respect as directed by the Engineer- in- charge. |
| 246 | Foundation |
| 247 | Ground floor |
| 248 | ADMINISTRATIVE |
| 249 | ACADEMIC BLOCK |
| 250 | GIRLS HOSTEL |
| 251 | SINGLE QUARTER |
| 252 | FAMILY QUARTER |
| 253 | First floor |
| 254 | ACADEMIC BLOCK |
| 255 | GIRLS HOSTEL |
| 256 | SINGLE QUARTER |
| 257 | FAMILY QUARTER |
| 258 | Terace floor |
| 259 | ACADEMIC BLOCK |
| 260 | GIRLS HOSTEL |
| 261 | FAMILY QUARTER |
| 262 | Priming one coat with water bound wall cement primer. |
| 263 | OUTERSIDE |
| 264 | Ground floor |
| 265 | ADMINISTRATIVE |
| 266 | ACADEMIC BLOCK |
| 267 | GIRLS HOSTEL |
| 268 | SINGLE QUARTER |
| 269 | FAMILY QUARTER |
| 270 | First floor |
| 271 | ADMINISTRATIVE |
| 272 | ACADEMIC BLOCK |
| 273 | GIRLS HOSTEL |
| 274 | SINGLE QUARTER |
| 275 | FAMILY QUARTER |
| 276 | Terace floor |
| 277 | ACADEMIC BLOCK |
| 278 | GIRLS HOSTEL |
| 279 | FAMILY QUARTER |
| 280 | INNER SIDE |
| 281 | Ground floor |
| 282 | ADMINISTRATIVE |
| 283 | ACADEMIC BLOCK |
| 284 | GIRLS HOSTEL |
| 285 | SINGLE QUARTER |
| 286 | FAMILY QUARTER |
| 287 | First floor |
| 288 | ADMINISTRATIVE |
| 289 | ACADEMIC BLOCK |
| 290 | GIRLS HOSTEL |
| 291 | SINGLE QUARTER |
| 292 | FAMILY QUARTER |
| 293 | Terace floor |
| 294 | ACADEMIC BLOCK |
| 295 | GIRLS HOSTEL |
| 296 | FAMILY QUARTER |
| 297 | Finishing wall surface of walls with cement basedwall putty ( water based) of approved make and finished smooth and even surface to receive painting including costof scaffoldings, staging charges with cost of all material & taxes labourT&P etc complete.(A/R 2006, Pg-236, item no-2) |
| 298 | Ground floor |
| 299 | ADMINISTRATIVE |
| 300 | ACADEMIC BLOCK |
| 301 | GIRLS HOSTEL |
| 302 | SINGLE QUARTER |
| 303 | FAMILY QUARTER |
| 304 | First floor |
| 305 | ADMINISTRATIVE |
| 306 | ACADEMIC BLOCK |
| 307 | GIRLS HOSTEL |
| 308 | SINGLE QUARTER |
| 309 | FAMILY QUARTER |
| 310 | Terace floor |
| 311 | ACADEMIC BLOCK |
| 312 | GIRLS HOSTEL |
| 313 | FAMILY QUARTER |
| 314 | Painting two coats with plastic emulsion paint with a approved quality primerto make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge. |
| 315 | Ground floor |
| 316 | ADMINISTRATIVE |
| 317 | ACADEMIC BLOCK |
| 318 | GIRLS HOSTEL |
| 319 | SINGLE QUARTER |
| 320 | FAMILY QUARTER |
| 321 | First floor |
| 322 | ADMINISTRATIVE |
| 323 | ACADEMIC BLOCK |
| 324 | GIRLS HOSTEL |
| 325 | SINGLE QUARTER |
| 326 | FAMILY QUARTER |
| 327 | Terace floor |
| 328 | ACADEMIC BLOCK |
| 329 | GIRLS HOSTEL |
| 330 | FAMILY QUARTER |
| 331 | Wall painting two coats with Weather coat paint (1st quality) exterior grade of approved make & with a approved quality primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance,cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge. |
| 332 | Ground floor |
| 333 | ADMINISTRATIVE |
| 334 | ACADEMIC BLOCK |
| 335 | GIRLS HOSTEL |
| 336 | SINGLE QUARTER |
| 337 | FAMILY QUARTER |
| 338 | First floor |
| 339 | ADMINISTRATIVE |
| 340 | ACADEMIC BLOCK |
| 341 | GIRLS HOSTEL |
| 342 | SINGLE QUARTER |
| 343 | FAMILY QUARTER |
| 344 | Terace floor |
| 345 | ACADEMIC BLOCK |
| 346 | GIRLS HOSTEL |
| 347 | FAMILY QUARTER |
| 348 | Providing Mat finished Granite stone prepolished 20mm thick of areaabove 0.40 Sqm in flooring of approved quality, colour and size in floors, treads on steps and landings in all floors at all height on 6mm thick bed of Tile Adhesive laid in proper slope and gradient ,grouting thejoints with Tile Grout mixed with required quantities ofpigments of approved make to match the shades of the granite tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, Labour cess ,sundries, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge.Tile Adhesive Make:-UltraTech Tilefixo NT.Tile Grout Make:-UltraTech Tilefixo Grout CG. |
| 349 | Ground floor |
| 350 | ADMINISTRATIVE |
| 351 | ACADEMIC BLOCK |
| 352 | Providing 16mm. thick finished kota stone flooring using kota stone of approved quality, colour and size above 0.10 sqm in floors, treads on steps and landing on 6mm thick bed of Tile Adhesive, grouted with Tile Grout mixed with required quantity of pigment of approved marks to match the shades of the kota stone to kota colour if required, watering and curing for the required period , including cost, conveyance, loading, unloading, royalties, and taxes of all materials, cost of all labour, sundries, T&P required for the work including cost of rubbing mechanically and wax polishing etc complete in all floors at all height in all respect as directed by the Engineer-in-charge.Tile Adhesive Make:-UltraTech Tilefixo NT.Tile Grout Make:-UltraTechTilefixo grout CG. |
| 353 | Ground floor |
| 354 | ACADEMIC BLOCK |
| 355 | GIRLS HOSTEL |
| 356 | Providing 16mm. thick finished kota stone in dado/skirting using kota stone slab above 0.10 sqm of approved quality, colour and size in dado, risers of steps on 6mm thick bed of Tile Adhesive (IS15477), grouted with Tile Grout laid in proper slope Tile Grout mixed with required quantity of pigment of approved marks to match the shades of the kota tiles to kota colour if required, watering and curing for thr required period, including cost, conveyance, loading, unloading, royalties, and taxes of all materials, cost of all labour, sundries, T&P required for the work including rubbing mechanically and wax polishing etc. in all floors at all height complete in all respect as directed by the Engineer-in-charge.Tile Adhesive Make:-UltraTech Tilefixo NT.Tile Grout Make:-UltraTech Tilefixo Grout CG. |
| 357 | Ground floor |
| 358 | ACADEMIC BLOCK |
| 359 | GIRLS HOSTEL |
| 360 | Providing vitrified tile flooring using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13755 of 600mmx600mm (Plain Ivory) (homogeneous) of premium quality (Make :- NITCO / RAK / Johnson or equivalent) in floors, treads on steps and landings on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the vitrified tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. |
| 361 | Ground floor |
| 362 | ADMINISTRATIVE |
| 363 | ACADEMIC BLOCK |
| 364 | GIRLS HOSTEL |
| 365 | SINGLE QUARTER |
| 366 | FAMILY QUARTER |
| 367 | First floor |
| 368 | ACADEMIC BLOCK |
| 369 | GIRLS HOSTEL |
| 370 | SINGLE QUARTER |
| 371 | FAMILY QUARTER |
| 372 | Terace floor |
| 373 | ACADEMIC BLOCK |
| 374 | GIRLS HOSTEL |
| 375 | FAMILY QUARTER |
| 376 | Providing vitrified tile in dado/ skirting using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13755 of 600mmx600mm, (Plain Ivory) (homogeneous) (Make :- NITCO / RAK / Johnson or equivalent) in dado/ skirting,riser of steps,wall on on 12mm thick bed of cement mortar of mix (1:3) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shadesof the vitrified tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, Labour cess ,sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. |
| 377 | Ground floor |
| 378 | ADMINISTRATIVE |
| 379 | ACADEMIC BLOCK |
| 380 | GIRLS HOSTEL |
| 381 | SINGLE QUARTER |
| 382 | FAMILY QUARTER |
| 383 | First floor |
| 384 | ACADEMIC BLOCK |
| 385 | GIRLS HOSTEL |
| 386 | SINGLE QUARTER |
| 387 | FAMILY QUARTER |
| 388 | Terace floor |
| 389 | ACADEMIC BLOCK |
| 390 | GIRLS HOSTEL |
| 391 | FAMILY QUARTER |
| 392 | Ceramic tile/ Anti skid tile of 30cmX30cm/ 40cmX40cm special, plain/printed series over 25mm thick bed CM(1:1)(A/R 2006, Pg-89, item no-16)(Floor tile) |
| 393 | Ground floor |
| 394 | ADMINISTRATIVE |
| 395 | ACADEMIC BLOCK |
| 396 | GIRLS HOSTEL |
| 397 | SINGLE QUARTER |
| 398 | FAMILY QUARTER |
| 399 | First floor |
| 400 | ACADEMIC BLOCK |
| 401 | GIRLS HOSTEL |
| 402 | SINGLE QUARTER |
| 403 | FAMILY QUARTER |
| 404 | Glazed ceramic tiles 20cmx30cm / 20cm x 20cm special plain /printed Wall tile series of premium grade 12mm thick bed CM(1:3)(A/R 2006, Pg-90, item no-17) |
| 405 | Ground floor |
| 406 | ADMINISTRATIVE |
| 407 | ACADEMIC BLOCK |
| 408 | GIRLS HOSTEL |
| 409 | SINGLE QUARTER |
| 410 | FAMILY QUARTER |
| 411 | First floor |
| 412 | ACADEMIC BLOCK |
| 413 | GIRLS HOSTEL |
| 414 | SINGLE QUARTER |
| 415 | FAMILY QUARTER |
| 416 | Supplying, fitting & fixing of Industrial vitrified tiles (30x30)cm in floors of approved make laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with slurry including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge |
| 417 | Ground floor |
| 418 | ADMINISTRATIVE |
| 419 | ACADEMIC BLOCK |
| 420 | GIRLS HOSTEL |
| 421 | Single leaf 2 hour rated Metal Fire doorProviding and fixing ofinsulated fire rated GI Sheet doors conforming to FD 120-I 30 classification of IS 3614 :2021with fire rating of 120 minutes integrity and 30 minutes insulation. The factory manufactured door frame and shutter assembly shall be made out of minimum 1.20 mm thick GI Sheet with minimum 120 GSM coating as per IS: 277. Door and frame should be finished with powder coating in standard RAL shade finish having DFT of minimum 30 microns. The door should carry a minimum 500 Hrs of salt spray test. All accressesories like hardware, vision panel, fire & smoke seal etc to be supplied by Fire door manufacturer only as per the guidelines laid down in IS 3614:2021.Every door must carry a label confirming to type of door & its fire rating.The door must carry a 5years valid test evidence from CBRI-Roorkee / NTH-Kolkata/ NABL accrediated lab which operates in accordance with ISO/IEC 17025. The Door frame shall be single rebate grooved profile of size minimum 100mm x 57mm made out of 1.20mm (18gauge) minimum thick galvanized steel sheet. Frames shall be butt / mitered joint and field assembeled with bolting system. Frames to have inbuilt grooved to accomodate Intumuscent fire seal strip . The frame should also be provided with fire rated EPDM smoke seal 20x4 mm conforming to IS: 3614:2021 or as per test evidence. It shall be fixed ingrooves, specifically cut in rebate on all the 3 sides of the frame.. All provisions should be mortised & provided with necessary inbuilt reinforcement to receieve appropriate hardware. Frames should be provided with back plate bracket for anchor fastner with 8-10 mm dia and minimum 80 mm long HDG fasteners, with Polyamide sleeves(Payable in extra item) for installation of frame in finished plastered masonary wall opening. Note :- For grouting of Steel frames in masonary installations ;cement sand mixture 1:3 ratio by civil contractor/fire rated PU foam or such fire rated material may be recommended except head member(Payable in extra item). Single leaf insulated fire rated door of FD 120 classification IS 3614:2021 with 120 minutes integrity and 30 minutes insulation - For staircase/exit pathway application / Refuge area. – Door frame fixed to exit opening with 10 nos. fasteners and doorassembly must be provided with 1 no. single point panic bar and external trim with key cylinder, 1 no. door closer with spring. Every Glass pane must carry a permanent marking of its glass manufacturer as per directions of the Engineer-in- Charge. MAKE :- TATA PRAVESH |
| 422 | ACADEMIC BLOCK |
| 423 | Double leaf 2 hour rated metal fire doorProviding and fixing of insulated fire rated GI Sheet doors conforming to FD 120-I 30 classification of IS 3614 :2021with fire rating of 120 minutes integrity and 30 minutes insulation. The factory manufactured door frame and shutter assembly shall be made out of minimum 1.20 mm thick GI Sheet with minimum 120 GSM coating as per IS: 277. Door and frame should be finished with powder coating in standard RAL shade finish having DFT of minimum 30 microns. The door should carry a minimum 500 Hrs of salt spray test. All accressesories like hardware, vision panel, fire & smoke seal etc to be supplied by Fire door manufacturer only as per the guidelines laid down in IS 3614:2021.Every door must carry a label confirming to type of door & its fire rating. The door must carry a 5years valid test evidence from CBRI-Roorkee / NTH-Kolkata/ NABL accrediated lab which operates in accordance with ISO/IEC 17025. The Door frame shall be single rebate grooved profile of size minimum 100mm x 57mm made out of 1.20mm (18gauge) minimum thick galvanized steel sheet. Frames shall be butt / mitered joint and field assembeled with bolting system. Frames to have inbuilt grooved to accomodate Intumuscent fire seal strip . The frame should also be provided with fire rated EPDM smoke seal 20x4 mm conforming to IS: 3614:2021 or as per test evidence. It shall be fixed ingrooves, specifically cut in rebate on all the 3 sides of the frame.. All provisions should be mortised & provided with necessary inbuilt reinforcement to receieve appropriate hardware. Frames should be provided with back plate bracket for anchor fastner with 8-10 mm dia and minimum 80 mm long HDG fasteners, with Polyamide sleeves(Payable in extra item) for installation of frame in finished plastered masonary wall opening. Note :- For grouting of Steel frames in masonary installations ;cement sand mixture 1:3 ratio by civil contractor/fire rated PU foam or such fire rated material may be recommended except head member(Payable in extra item).Double leaf insulated fire rated door of FD 120 classification IS 3614:2021 with 120 minutes integrity and 30 minutes insulation - For staircase/exit pathway application / Refuge area. - Door frame fixed to exit opening with 12 nos. fasteners and door assembly must be provided with 1 no. single point panic bar and external trim with key cylinder to active door shutter, 1 no. 2 pointpanic bar on inactive door leaf, 2 no. door closers with spring, 1 no. coordinator for sequencing.. Every Glass pane must carry a permanent marking of its glass manufacturer. (Make :- Tata Pravesh |
| 424 | ACADEMIC BLOCK |
| 425 | Providing and fixing of Hollow metal door at all levels from ISO 9001-2008 certified Manufacturer OEM . All hollow metal general purpose doors with or without vision panel. Pressed Galvanised steel Single /Double leaf of required sizes consisting of frame, shutter, infill and finish as detailed below and conforming to IS 277. All doors & frames should be finished with Thermosetting weather proof Powder Coating in desired RAL Shades. Approved manufacturerwhich should be ISO & CE Certified & IGBC registered company. Rate should include supply and installation of door and hardware set as mentioned in the door and hardware schedule. Door frame shall be Single rebate profile of size 100 x 50 mm made out of 1.20mm thick galvanised steel sheet (18 gauge). Frames should be butt jointed and field assembled with self tabs. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Door leaf should be 46mm thick fully flush double skin door with or without vision lite. Door leaf shall be manufactured from 0.8mm (22 guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate Hardwares. The infill material shall be Rookwool insulation. All doors NSD 12044 should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be as per joinery details with a screw on glass beeding on the inside. The glass should be 5mm tk clear Float glass. Hardwares should include the following:4 nos Hinges on each leaf1 no Door closer on each leaf, sliding door bolt and 1 no Mortice Dead lock1 Set D-type pull handle back to back on each leaf1 no Concealed flush bolt in inactive leaf of Double door, if any1 no vision glass on each leafFastners as required.The rate includes design supply, installation, testing, commissioning , transportation, T&P complete in all respect. MAKE :- TATA PRAVESH |
| 426 | Ground floor |
| 427 | ADMINISTRATIVE |
| 428 | ACADEMIC BLOCK |
| 429 | GIRLS HOSTEL |
| 430 | Supplying fitting and fixingfactory made 100% Solid WPC (Wood Polymer Composite ) - Door Frames. 100 mm x50 mm Single Rebated made from Wood Polymer Compqjte ( Single Extruded Process ) material 274.90/- comprising of virgin PVC polymer of K Value 57-60 ( Suspetsion Grade ), Calcium Carbonate and Per Run, Natural Fibers ( Wood Powder/ Rice Husk/ Wheat Husk) and Nontoxic additives fabricated with meter Ft Joints after applying PVC solvent Cement & screwed with full body treaded star headed screws having minimum frame density of 780 kg/ cmhaving good screw holding capacity ( Screw Withdrawal strength of ( Min. 990 N ). Minimum Compressive Strength of 58 N/mm2, Modulus of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof, water / Moisture Proof & Fire retardant & Fixed in position with SS Dash Fasteners / Hold Fast of required dia and length, , all as per specifications drawings as directed by the Engineer-In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company complete in all respect Make : Alstone, Century, Renyoarch |
| 431 | Ground floor |
| 432 | ADMINISTRATIVE |
| 433 | ACADEMIC BLOCK |
| 434 | GIRLS HOSTEL |
| 435 | SINGLE QUARTER |
| 436 | FAMILY QUARTER |
| 437 | First floor |
| 438 | ACADEMIC BLOCK |
| 439 | GIRLS HOSTEL |
| 440 | SINGLE QUARTER |
| 441 | FAMILY QUARTER |
| 442 | Supplying, Fitting & Fixing of Factory made Green new mika,Century, mikasamake 32mm thick I.S.I, marked post laminated flush doors with 1 mm thick laminate preseed onboth sides of flush door.With fitting and fixing of Al-drop,hydraulic door clousure,SS Tower bolt with/without vision panel,SS Door stopper,SS T and P, Required for the work to be complete in all respectas per the direction of the Engineer-in-charge.hardware( Dorma/Godrej) |
| 443 | Ground floor |
| 444 | ADMINISTRATIVE |
| 445 | ACADEMIC BLOCK |
| 446 | GIRLS HOSTEL |
| 447 | SINGLE QUARTER |
| 448 | FAMILY QUARTER |
| 449 | First floor |
| 450 | ACADEMIC BLOCK |
| 451 | GIRLS HOSTEL |
| 452 | SINGLE QUARTER |
| 453 | FAMILY QUARTER |
| 454 | 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. (DSR 2021 , Code no: 9.122.1) |
| 455 | Ground floor |
| 456 | ADMINISTRATIVE |
| 457 | ACADEMIC BLOCK |
| 458 | GIRLS HOSTEL |
| 459 | SINGLE QUARTER |
| 460 | FAMILY QUARTER |
| 461 | First floor |
| 462 | ACADEMIC BLOCK |
| 463 | GIRLS HOSTEL |
| 464 | SINGLE QUARTER |
| 465 | FAMILY QUARTER |
| 466 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 467 | Ground floor |
| 468 | ADMINISTRATIVE |
| 469 | ACADEMIC BLOCK |
| 470 | GIRLS HOSTEL |
| 471 | SINGLE QUARTER |
| 472 | FAMILY QUARTER |
| 473 | First floor |
| 474 | ACADEMIC BLOCK |
| 475 | GIRLS HOSTEL |
| 476 | SINGLE QUARTER |
| 477 | FAMILY QUARTER |
| 478 | Providing and fixing of Wooden fire cum accoustic doors with 32db as per BS:476 Part- 20 & 22 & IS 3614 part-1 & part-2 for stability , integrity and thermal insulation. 03 Criteria Wooden door confirming to IS 277 with the following specification. Recommended fire door shall have doors tested earlier at CBRI for maximum rating of 2hrs tested withor without vision panel. Individual Test certificates should be available for glass used in vision lites confirming the required fire ratings. Any deviation in specification other than what is mentioned in the test certificates are not allowed. Approved manufacturer Navair International Pvt Ltd or equivalent subject to architect’s approval and manufacturer should be ISO & CE Certified & IGBC registered company. Rate should include supply and installation of door and hardware set as mentioned in the door and hardware schedule. Door leaf shall be 83mm thick (75 mm thick with commercial ply + 4mm thick veneer on both side ) fully flush door with or without vision lite. 83mm thick shutter, comprising of 140mm x 90mm hardwood internal timber frame work,with infill of fire resistant & accoustic wool insulation of 48 Kg/m3 densitycoated with VIPER FRS 881 LH coating on both sides for insulation. The coated insulation shall be sandwiched between HILUX / PAMTECH Non Combustible (Calcium Silicate) Board on both sides (edge to edge on internal Hard wood frame and cladded with 6mm thick commercial ply on both sides, with exposed teak wood beading. 20 x4mm fire & smoke intumescent seal shall be used for shutter & frame . The Frame shall be 140 x 90mm of Hard Wood (Red MIrandi) and coated with VIPER Fire reatrdent Primer. The rebate shall be of 20mm x 79mm in Door Frame to accommodate the shutter in frame. In all doors, the pasting of the ply and 4mm thick veneer on both side should be done using automatic machine and should be free from any nails or perforations. Following hardwares are to be provided in Fire cum Acoustic door:8 nos SS Ball Bearing Hinges of size 100 x 89 x 3 mm2 nos heavy dute door closer TS73V/TS89F1 no complete set Panic bar (PHCR 1000 + 1500) for double leaf door along with Panic Trim from opposite side (PHT 2905 with 42mm half cylinder)RAVEN Delta Seal RP-120 (for perimeter of frame)RAVEN Astragal Seal RP-16si (for perimeter of shutter)RAVEN Door bottom Seal RP-8siHRD Fasteners M10 x 160mm.The cost includes all materials, labour, conveyance, scaffolding, T&P etc complete in all respect as per direction of EIC. |
| 479 | ACADEMIC BLOCK |
| 480 | Providing & Fixing Fabric Paneling as per manufcturers specification The panel comprise of 12mm thick recron acoustical synth.The top will be covered with fabric of approved make & shade fixed and stretched with PVC edge grippers,all complete as per design,drawing & direction of EIC.The cost includes all materials, labour, conveyance, scaffolding, T&P etc complete in all respect as per direction of EIC. |
| 481 | ACADEMIC BLOCK |
| 482 | Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures Make:- NCL Zyolx, Saint gobain, fenesta |
| 483 | Ground floor |
| 484 | ADMINISTRATIVE |
| 485 | ACADEMIC BLOCK |
| 486 | GIRLS HOSTEL |
| 487 | SINGLE QUARTER |
| 488 | FAMILY QUARTER |
| 489 | First floor |
| 490 | ACADEMIC BLOCK |
| 491 | GIRLS HOSTEL |
| 492 | SINGLE QUARTER |
| 493 | FAMILY QUARTER |
| 494 | Providing and fixing Colour coated galvanized steel louvers of Jindal /NCL Seccolor / TATA Pravesh make With Fixed windows made of pre - painted steel (base steel as per IS 513 of -0.58 mm thick \"D\" quality, galvanized as per IS 277 with zinc of 120 GSM) primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paintof 12-16 microns thick and back coated with 5-7 microns thick alkyd backer, section for outer frame of 33 x 57 mm Box Section for mullion 33 x 57 mm, and section for beading should be 12 x 25 mm with 4 mm pinhead glass for ventilators with Ethyl propylene Damien monomer Gasket (EPDM) and the sections cut to length mitre joined with corner bracket centre mullions fixed using mullion cap and with handle made of high grade aluminium powder coated and nylon receiver, corner brackets made of CRCA with Zinc Phosphate, Mullion caps made of glass filled nylon, frames fixed to the concrete /masonry wall by means of selfexpanding screws complete for finished item of work. Fixed louvers 4\"-0\" x 2\"-0\" (1219.2 x 609.6 mm) (Box section) outer frame section size of 33 x 57 mm Mullion section size of 33 x 57 mm |
| 495 | Ground floor |
| 496 | ADMINISTRATIVE |
| 497 | ACADEMIC BLOCK |
| 498 | GIRLS HOSTEL |
| 499 | SINGLE QUARTER |
| 500 | FAMILY QUARTER |
| 501 | First floor |
| 502 | ACADEMIC BLOCK |
| 503 | GIRLS HOSTEL |
| 504 | SINGLE QUARTER |
| 505 | FAMILY QUARTER |
| 506 | Providing and fixing in position 50mm, thick precast cement concere jally (1:2:4) hard granite chips including roughening, cleaning, fixing and finishing in cement mortar (1:3) etc., complete.(sor 2022 25.1 .2) |
| 507 | Ground floor |
| 508 | GIRLS HOSTEL |
| 509 | SINGLE QUARTER |
| 510 | ACADEMIC BLOCK |
| 511 | FAMILY QUARTER |
| 512 | First floor |
| 513 | ACADEMIC BLOCK |
| 514 | GIRLS HOSTEL |
| 515 | SINGLE QUARTER |
| 516 | FAMILY QUARTER |
| 517 | Terace floor |
| 518 | ACADEMIC BLOCK |
| 519 | GIRLS HOSTEL |
| 520 | FAMILY QUARTER |
| 521 | Providing and laying Broadloom roll Solution dyed carpet, with haritage nylon content of 100% BCF Polyamide 6 and polypropylene woven backing. The primary backing has to be polypropylene & secondary backing shall be polypropylene sandwich backing . The total Thickness should be 6.1mm with antistatic, thermal resistance , sound insulation & sound absorption properties. Carpet to have fire resistance of Cfl-s1 ( with adhesion) and suitable for allergies.Product to have a Cradle to cradle certification& classification of use should be 33 commercial heavy use. Rates including complete installation with backing foam, necessary stitching etc. including the cost of all material, cost of all labor, conveyance , taxes, royalties loading & unloading, sundries, watering & curing, T&P etc. complete as per the direction of the Engineer-in –charge. Aluminum chhannel : providing & fixing of 100 mm proprietary Aluminiumskirting of approved make necessary adhesive/ fittings ,complete as per the direction of the Engineer-in –charge Make:- Aeroceil, Bsr Calsi, Duxan |
| 522 | ACADEMIC BLOCK |
| 523 | Supply and Installation of high Density wall panelling with 20 mm thick mat solo micro fibre pine wood magnesite bonded wood particle panels of size 1200mm X 600 mm X 15mm having Density-600 kg/mt cube ,weight - 9 kg /sq mt, NRC- 0.9, Fire Class - 1&P & Thermal Heat Resistance - 0.1 W/mK Climate ( degree Centigrade , RH - 50-95 , Green VoC , RC% - Low & 30 climate from ambient to saturation, Moisture Movement - 0.02%are to be fixed with strut MC38 channel 0.90mm x 3600mm to be fixed directly on the surface of the wall with 50mm/10mm SS crew & PVC grip horizontally / Vertically as per the site requirement. The square edged mat solo panels is to be screwed with 38 mm phosphorus coated self threded screw with edge matching. These acoustic panels can be spray painted of choice colour. Test certificate of the used products shall be submitted after procurement of materials.Make:- Aeroceil,BRS Calsi,Duxan |
| 524 | Ground floor |
| 525 | ACADEMIC BLOCK |
| 526 | Supply and Installation of high Density wall panelling with 20 mm thick mat solo micro fibre pine wood magnesite bonded wood particle panels of size 1200mm X 600 mm X 15mm having Density-600 kg/mt cube ,weight - 9 kg /sq mt, NRC- 0.9, Fire Class - 1&P & Thermal Heat Resistance - 0.1 W/mK Climate ( degree Centigrade , RH - 50-95 , Green VoC , RC% - Low & 30 climate from ambient to saturation, Moisture Movement - 0.02%are to be fixed with strut MC38 channel 0.90mm x 3600mm to be fixed directly on the surface of the wall with 50mm/10mm SS crew & PVC grip horizontally / Vertically as per the site requirement. The square edged mat solo panels is to be screwed with 38 mm phosphorus coated self threded screw with edge matching. These acoustic panels can be spray painted of choice colour. Test certificate of the used products shall be submitted after procurement of materials. Make:- Aeroceil, Bsr Calsi, Duxan |
| 527 | ACADEMIC BLOCK |
| 528 | WALL PANELING WITH WOODEN SLAT HDF PLANK(FIRE RESISTANCE) |
| 529 | Supply & installation ofwall paneling of wooden slats (2440 mm x 128 mm x 15 mm thick) surco high density fiberboard made out ofpure pinewood particles, Fire Resistance - (Class 1 )Pink in colour core with5 test Fire Resistance BS 476 part 5 , BS 476 part 6 , BS 476 part 7 ISO 1182. ASTM E662 Smoke Density -laminated finish, perforated wooden grooved HDF slatsL16-2 (2 mm grooves @ 8 mm centers),tongue-groove edge for a seamless look of lineal dimension size (2440 mm x 128 mm x 15 mm thick) having density 700 Kg /m3, weight -9 Kgs/m2 with back fleecs from soundtex Germany nonwoven acoustic to be pasted on slats surco is to be installed by using GI strut system. The technical parameters are as follows Core Variants - Fiberboard, Climate (OC RH) – 50, 70 Light reflectance – 75%,Green (RC %) – 25, Hygiene (VoC, Clean room) – Low, Class 1,Strength, Load capacity (Kg) - Anti sag, Ball-Impact.The wall paneling system shall include GI Wall channel (CC22) having thickness 0.45mm, length 3600mm, unequal flanges of 15 & 20mm and web of 22mm should be fixed on the wall with nylon sleeves and suitable fasteners at every 300mm centers,in the direction perpendicular to each other at every 600mm centers upto the desired height. Synth poly fiber PF 5 x 50 wool of 500 gsm to be filled between the horizontal & vertical studs as in filler with the help of wire / stick 7 adhesive. The framework will maintain 38 mm gap from the walls. Now clad the wooden slats surco on the CC 18 with the help of center & edge clips to get better locking of slats. The tongue & groove are to be properly aligned to get flush look . Test certificate of the use products shall be submitted after procurement of materials. Make:- Aeroceil,BRS Calsi,Duxan |
| 530 | ACADEMIC BLOCK |
| 531 | SITC of Acoustic wall panelling of soak plane having NRC 0.71, fire class 1&P, density400kg/cum, Green VoC low, RC% low, Climate 0 degreee centigrade of size 1200mmX600mmX20mm to be fixed horizontally on CC25 GI channel/ aluminium channel of 50mmX25mm which area to be fixed vertically up to the appropriate height in three lines in the centre portion of the pillar at 300mm centre to centre leaving 0.45m on both side up to full height. The channel will be screw fixed with 50X10 PVC wall grip & 50X10 ND screw. The H-spline system is horizontally fixed on the CC25/aluminium channel by 25mm driver screw. The soak plane panel will be slutted-in to the H-spline system groove & pressed till the spline edge goes fully into the the panel. Then one more H-spline channel of1200mm of length to be pushed on the upper side of the panel & screwed properly, so likewise the installation of panels goes up. The cost includes all materials, labour, conveyance, scaffolding, T&P etc complete in all respect as per direction of EIC. Make:- Aeroceil,BRS Calsi,Duxan |
| 532 | ACADEMIC BLOCK |
| 533 | Supply and Installation of false ceiling 8 mm thick Aeroloc magnesium oxide HDFR boards of size 1200 x 2400 mm having Density-1000 kg/mt cube, with STC- 34 – 50, weight - 8.5 kg /sq mt, Fire Class - 1&P & Thermal Heat Resistance - 0.11792 W/mK Climate ( degree Centigrade , RH - 50-95 , Green VoC , RC% - Low & 30 Water resistant with wet expansion less than -0.02% from ambient to saturation, Moisture Movement - 0.02% from Anutone / Win Win / Magnum are to be fixed with Philips head screw is fixed by using concealed ceiling system. The concealed ceiling system shall include GI Wall channel(WC 25) having thickness 0.45 mm, length 3600 mm, unequal flanges of 15 & 20 mm and web of 22 mm should be fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300 mm centers. Then suspend Main channels(MC 45) having thickness 0.9 mm, length 3600 mm, equal flanges of 15 mm and web 45mm from the soffit at every 1200 mm centers with Suspender angle(SA 25) having thickness 0.45 mm, unequal flanges of 25 & 10 mm. GI Cross channel(CC 25) having thickness 0.45 mm, length 3600 mm, knurled web 35mm, depth of 25 mm and equal flanges 9.5 mm is fastened to the Main channel in the direction perpendicular to the Main Channel at every 600mm centers. Now the jointing & finishing of the same will be done by using Aeroceil jointing kit consist of powder mixed with water and apply the same with flat flap on the boards joints to finish the surface of the boards so as to look flush. Apply synthetic poly fiber PF 5 x 50 acoustic wool of 50 kg density to be kept on the top of the ceiling by laying on the framework. Test certificate of the use products shall be submitted after procurement of materials. |
| 534 | ACADEMIC BLOCK |
| 535 | Providing and laying in position 18 mm thick homogeneous hardwood flooring of Aeroceil American walnut plank or Equivalent of size 18mm x 127mm x 305-1500 mm with tongue and groove joints to secure long lasting joint. The Floor is finished on top with seven course of UV curved formaldehyde free lacquer. The planks are installed on 2 mm foam and 12 mm waterproof ply nail down & using adhesive in the groove of the board all complete including all accessories (Skirting, Profile) etc. all complete including cost, Conveyance, royalty, taxes of all materials, labour T&P etc, complete as per direction of Engineer-in-charge.Make:- Aeroceil,BRS Calsi,Duxan |
| 536 | ACADEMIC BLOCK |
| 537 | Providing and fixing of wooden skirting by using the plank of size 16mm x 60mm x 2000RL with the help of headless nail all all complete including all accessories (Skirting, Profile) etc. all complete including cost, Conveyance, royalty, taxes of all materials, labour T&P etc, complete as per direction of Engineer-in-charge.The cost includes all materials, labour, conveyance, scaffolding, T&P etc complete in all respect as per direction of EIC.Make:- Aeroceil,BRS Calsi,Duxan |
| 538 | ACADEMIC BLOCK |
| 539 | CEILING WITH AEROSQUIREon GRID SYSTEM Supply and Installation of Aeroceil false ceiling12 mm gypsum perforated square edge 10/20 ( 10 mm square perforated 20 mm pitch TOA - 15 %) gypsum tiles having the technical parameters are as follows : Core - GFR gypsum, Fire – Class A & P, Acoustics – NRC 0.80,Climate (degree C RH) – 50, 90, Light reflectance 80 %,Green (RC %) – 25, Hygiene (VoC, Clean room) – Low , having pixel size 10X10 mm square perforated at 20 mm center tile of size 595 x 595 x 12.5 mm having density 700 Kgs/ m3, weight - 8 kg/m2 . The concealed ceiling system shall include GI Wall channel(WC 25) having thickness 0.45 mm, length 3600 mm, unequal flanges of 15 & 20 mm and web of 22 mm should be fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300 mm centers. Then suspend Main channels(MC 45) having thickness 0.9 mm, length 3600 mm, equal flanges of 15 mm and web 45mm from the soffit at every 1200 mm centers with Suspender angle(SA 25) having thickness 0.45 mm, unequal flanges of 25 & 10 mm. GI Cross channel(CC 25) having thickness 0.45 mm, length 3600 mm, knurled web 35mm, depth of 25 mm and equal flanges 9.5 mm is fastened to the Main channel in the direction perpendicular to the Main Channel at every 600mm centers. Now the jointing & finishing of the same will be done by usingjointing kit consist of powder mixed with water and apply the same with flat flap on the boards joints to finish the surface of the boards so as to look flush. Apply synthetic poly fiber PF 5 x 50 acoustic wool of 50 kg density to be kept on the top of the ceiling by laying on the framework. Test certificate of the use products shall be submitted after procurement of materials. The cost includes all materials, labour, conveyance, scaffolding, T&P etc complete in all respect as per direction of EIC. Make:- Aeroceil,BRS Calsi,Duxan |
| 540 | ACADEMIC BLOCK |
| 541 | AUDITORIUM BACK WALL PANELLING WITH MAT EBONYSupply and Installation of Aeroceil Acoustic wall panelling with 15 mm thick Matt Ebony micro fibre pine wood magnesite bonded woodsquare edge of black colour of size 1200 x 600 mm with having Density-600 kg/mt cube , weight - 9 kg /sq mt, Fire Class - 1&P, NRC - 0.9 & Thermal Heat Resistance - 0.1 W/mK Climate ( degree Centigrade , RH - 50-95 , Green VoC , RC% - Low & 30 climate from ambient to saturation, Moisture Movement - 0.02% are to be fixed on GI channel WC25 of 3600mm (Length) X 0.45mm (Thick) which will be fixed on the wall either vertically or horizontally depending on the site condition at 300mm C/C. The GI Channel CC 25 will be fixed on wall with 50 mm x 10mm MS screw with suitable PVC Nylon grip. Finally the Matt Ebony panels of size 1200 x 600 mm x 15mm will be fixed on the channels with 25mm phosphorus dry wall screws etc all complete as per direction of EIC. Test certificate of the use products shall be submitted after procurement of materials.The cost includes all materials, labour, conveyance, scaffolding, T&P etc complete in all respect as per direction of EIC. Make:- Aeroceil,BRS Calsi,Duxan |
| 542 | ACADEMIC BLOCK |
| 543 | Supply and installation of Aeroceil Stretchable acoustical fabric hushGrafix fabric system by using Aeroceil FR Grade hush Grafix fabric of size 1400 mm width, shall be stretched by using wooden base 10 mm thick rigid vinyl stretch tracks half wrap/ full wrap 15 mm FS15 & mid seam 15 mm FS 15, 20 mm pinewood magnesia bonded Strand board, Synthetic poly fiber 5x50 infill with requisite accessories & tools. Pinewood wood based wool fiber having 15 mm thick square edge is first installed on the wall along the marking lines with metal fasteners inserted at 300 mm centers FS 15 tracks to be installed on wooden base after applying stick S7 adhesive on both surfaces for a true & continuous secure grip, & heavy - duty fasteners at 150 mm centers on both sides of stretch tracks. Pinewood wool panels having square edge Magnesite bonded pinewood fibers panels of size600 x 1200 x20 mm having density 400 Kg /m3 , weight 4 kg which is fixed to GI Channel CC25 on walls placed at 600 mm centersvertically / Horizontally with suitable fasteners with MC 45 at 1200 c/c & WC 25 is for supporting the main frame.. Synthetic poly fiber PF 5 x 50 mm thick adhered on strand tracks by following the fabric thread line or pattern. The fabric Hush Grafix is stretched & tucked into the stretch tracks & secure into the locking jaws so that it will be smooth, free of wrinkles with the tucking tools. Note - minimum 50 mm additional Anuton fabric is required for tucking hence maximum module wall fabric width would be 1600 mm The technical parameters of the system are core - pinewood fibre & polyfiber Fire - 1& P Acoustic - NRC 0.85 Climate OCRH - 49, 90 Termite resistance - yes , light reflectance - colour dependant , Green RC % - 25 , Hygiene( Voc , Clean room ) - Low , Class 1. Test certificate will be submitted after procurement of materials. Make:- Aeroceil,BRS Calsi,Duxan |
| 544 | ACADEMIC BLOCK |
| 545 | 2.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size HG chips including all cost, conveyance, royalty & taxes etc.comp.to work site for new work as per the specification approved by the department & direction of E.I.C |
| 546 | ADMINISTRATIVE |
| 547 | ACADEMIC BLOCK |
| 548 | ACADEMIC BLOCK |
| 549 | GIRLS HOSTEL |
| 550 | GIRLS HOSTEL |
| 551 | SINGLE QUARTER |
| 552 | SINGLE QUARTER |
| 553 | FAMILY QUARTER |
| 554 | FAMILY QUARTER |
| 555 | DRY WALL PARTITION Providing and fixing Aeroceil make 66 mm thick partition upto ceiling height consisting of G.I. frame and 2 * 8 mm thick plain edge having density 1250 kg / sqm including providing and fixing of frame work made of special section power pressed / roll form of G.I. sheet with zinc coating of 120 gms / sqm (both side inclusive) consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.55 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with floor and ceiling at the spacing of 610 mm centre to centre with dash fastener or metal screws with nylon plugs and the studs 48 mm wide having one flanges of 48 mm and other flanges of 50 mm and 0.55 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts including with 8 mm thick double skin oxide board, highly fire resistant and weather resistant anti termite, sound insulation board with 30 & 37dB the frequency range 100-3150 Hz complete as per the direction of the Engineer-in-charge. |
| 556 | Ground floor |
| 557 | ADMINISTRATIVE |
| 558 | Supplying and Fixing of M.S. Window Grill made out of M.S Flatconforming to IS 2062/2006 painted with Red Oxide Primer as per the design approve by E.I.C including cost,conveyance of all materials,priming,and labour for fitting fixing etc.complete as per the instruction of Engineer-in-Charge |
| 559 | Ground floor |
| 560 | ADMINISTRATIVE |
| 561 | ACADEMIC BLOCK |
| 562 | GIRLS HOSTEL |
| 563 | SINGLE QUARTER |
| 564 | FAMILY QUARTER |
| 565 | First floor |
| 566 | ACADEMIC BLOCK |
| 567 | GIRLS HOSTEL |
| 568 | SINGLE QUARTER |
| 569 | FAMILY QUARTER |
| 570 | Terace floor |
| 571 | ACADEMIC BLOCK |
| 572 | GIRLS HOSTEL |
| 573 | FAMILY QUARTER |
| 574 | Painting two coat with approved synthetic enamel paint to new wood & iron workincluding cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge. |
| 575 | Ground floor |
| 576 | ADMINISTRATIVE |
| 577 | ACADEMIC BLOCK |
| 578 | GIRLS HOSTEL |
| 579 | SINGLE QUARTER |
| 580 | FAMILY QUARTER |
| 581 | First floor |
| 582 | ACADEMIC BLOCK |
| 583 | GIRLS HOSTEL |
| 584 | SINGLE QUARTER |
| 585 | FAMILY QUARTER |
| 586 | Terace floor |
| 587 | ACADEMIC BLOCK |
| 588 | GIRLS HOSTEL |
| 589 | FAMILY QUARTER |
| 590 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. |
| 591 | Ground floor |
| 592 | ADMINISTRATIVE |
| 593 | ACADEMIC BLOCK |
| 594 | GIRLS HOSTEL |
| 595 | SINGLE QUARTER |
| 596 | FAMILY QUARTER |
| 597 | First floor |
| 598 | ACADEMIC BLOCK |
| 599 | GIRLS HOSTEL |
| 600 | FAMILY QUARTER |
| 601 | Terace floor |
| 602 | ACADEMIC BLOCK |
| 603 | Desgining, fabricating, supplying and installing in position in solid & metallic color of approved shade made out of 4mm thick aluminum composite panel material consisting of 3mm thick FR grade mineral core sandwich between 2 aluminum coil of alloy-AL3105-H16/H24 OF 0.5mm thickness making overall thickness of 4 mm. The aluminum composite panel cladding sheet shall be coil coated with Kynar 500 based PVDF/lumiflon (FEVE) based Coating (thickness 25 micron) and service coating on the reverse side shall be with PU (Thickness 5-7micron) base and coating shall be confirm to AAMA2605 standard with 10-yrs warranty done on a color coating line located in India Make:- Viva/Alucobond/alpolic |
| 604 | ACADEMIC BLOCK |
| 605 | ELE |
| 606 | ACADEMIC |
| 607 | INTERNAL |
| 608 | Sub-Head I (modular Wiring Items) |
| 609 | Recessed wirring tolight point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI markedMake- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEIwith 20 mm dia HMS FRLS PVCconduitISI markedMake-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type)switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 610 | GROUP-A |
| 611 | GROUP-B |
| 612 | GROUP-C |
| 613 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision).(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 614 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type))with suitable size modular box & cover( flame retradant type) including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius ) /Panasonic (vision).(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 yearsagainst manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 615 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type))with suitable size modular box & cover( flame retradant type) including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision)(For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 616 | Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6Aswitch & socket(modular type) ( ( flame retradant type) with suitable size modular box & metallic cover plate (both side)( flame retradant type)including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius )/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 617 | Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos6Aswitch & socket(modular type) ( ( flame retradant type) with suitable size modular box & metallic cover plate (both side)( flame retradant type)including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 618 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSinsulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI inrecessed HMS FRLS PVCconduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallicheavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 619 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSinsulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI inrecessed HMS FRLS PVCconduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallicheavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 620 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSinsulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI inrecessed HMS FRLS PVCconduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallicheavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 621 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSinsulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI inrecessed HMS FRLS PVCconduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallicheavy dutyconduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5) |
| 622 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSinsulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI inrecessed HMS FRLS PVCconduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32mm dia non metallicheavy dutyconduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4) |
| 623 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSinsulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI inrecessed HMS FRLS PVCconduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallicheavy dutyconduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6) |
| 624 | Supplying and installation of 25A AC starter Modular type, Schneider/Siemens/Legrand coil voltage-230 Volt A.C.on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 625 | Supply and fixingCALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor , A catagory ISI marked as approved .as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 626 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling roseas per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 627 | S/F of 5 step typeModular electronic Fan RegulatorISI Marked with all connection completein all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 628 | Sub-Head II (Light fitting Fixture & Fan) |
| 629 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Orient/Bajaj) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 630 | Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 631 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. |
| 632 | Supplying and fixing of Energy efficient Recess /Surface mounted square/round shaped LED luminaire made up of CRCA powder coatedsheet steelof 36W (595X595X70MM)and system lumens output not less than 4680lumens (130 lm/ wt)withdiffusers for better light transmission and pure effect with High luminous flux LEDs for better light output, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV,complete with Non integrated isolated electronic driver(protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty)supply .as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5 years. |
| 633 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaireof dimension of consists ofwhite powder coated , die-castAlluminiumhousingwith high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not lessthan 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operationon 220 V to 240 Vsupply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 634 | SITC of energy efficient LED tube light fittings with decorative alluminiumbatten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories withdiffuser having 2 years warrantyi/c connection etc as requiredas per direction of Engg.-in-Charge.(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 635 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 636 | Supply and fixing of 10 WattLED BH Fitting (panasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro/Halonix/Orient.) |
| 637 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 638 | BDBS,DB,AC DB,FLOOR PANELS,MCBS |
| 639 | Supplying and fixing of following mentionedway, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9as per direction of Engg.-in-Charge. The Distribution boardsshould be Replacement Warranty will be 3 years. |
| 640 | 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 641 | Supply and fixing of 12 wayDD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years |
| 642 | 2+4 way MCB EnclosureDB (GLAZEDdoor)(only each EM. CONNECTION UPS LOAD)Warranty on DB is 3 years |
| 643 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9.the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on MCB is 3 years. |
| 644 | Supplying and fixing 40 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. TheMCBshould be Replacement Warranty will be 3 years.. |
| 645 | Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 4P, 415 volts, RCCB 30mA .Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . TheMCBshould be Replacement Warranty will be 3 years. |
| 646 | Supplying and fixing 6-32Amps rating,C series,10KA breaking capacity, DP 240 volts, MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge.TheMCBshould be Replacement Warranty will be 3 years. |
| 647 | Supplying and fixing 40Amps rating,C series,10KA breaking capacity, DP 240 volts, MCBMake-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge. TheMCBshould be Replacement Warranty will be 3 years. |
| 648 | Supplying and fixing 40Amps 2P 240 volts RCCB 30 mAMake-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCBshould be Replacement Warranty will be 3 years. |
| 649 | Supplying and fixing 63Amps rating,C series,10KA breaking capacity, 4P 415 volts MCBMake-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCBshould be Replacement Warranty will be 3 years. |
| 650 | Supplying and fixing 63Amps 4P 415 volts RCCB 30 mAMake-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCBshould be Replacement Warranty will be 3 years. |
| 651 | (Earthing) INSTALLATION |
| 652 | S/IT/C of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked withG. I. nutbolts& washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing systemshould be Replacement Warranty will be 2 years |
| 653 | Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge. |
| 654 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 655 | CABLINGAND END TERMINATIONMAIN AREA |
| 656 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE propertyAL. conductor power cable of 1.1 KV gradeMake- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI of following size cables as per direction of Engg.-in-Charge.Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 657 | 4core x 16 sq mm |
| 658 | 4 core x 6 sq mm (for small power) |
| 659 | 3.5core x 50 sq mm |
| 660 | 3.5core x 95 sq mm ,2 RUNS |
| 661 | LAYINGOF CABLE |
| 662 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMdirect in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 663 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade sizeexceeding 25 SQ. MMbut not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 664 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMdirect in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 665 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade sizeexceeding 25 SQ. MMbut not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 666 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMin open duct etc as required as per direction of Engg.-in -charge. |
| 667 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade sizeexceeding 25 SQ. MMin open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 668 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMin surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 669 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 670 | Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 671 | 4 core x16sq mm |
| 672 | 3.5 core x50 sq mm |
| 673 | 3.5 core x95 sq mm |
| 674 | Providing,fixing and laying offollowing dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 675 | 50 mm dia |
| 676 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete withfitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 677 | 200 mm dia |
| 678 | PANELS |
| 679 | MAIN CONTROLPANEL AT GF |
| 680 | S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed asG.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessoriesmust be 3 years & compelete test certificate must be submitted along with panel board including component list.Separate Aluminium Earth bus bar should be installed. |
| 681 | CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER |
| 682 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W)of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Traysshould be minimum of104.8Kg/meter at the span of1.5Meter as per UL specificationsas required as per direction of Engg.-in-Charge. |
| 683 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W)of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Traysshould be minimum of104.8Kg/meter at the span of1.5Meter as per UL specificationsas required as per direction of Engg.-in-Charge. |
| 684 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 400mm(W)of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Traysshould be minimum of104.8Kg/meter at the span of1.5Meter as per UL specificationsas required as per direction of Engg.-in-Charge. |
| 685 | Supplying,fixing ofFLOOR RACE WAY WITH JUNCTION box GALVANIZED(GC) typeAS PER EN-ISO-1461 , with internal dimensions ofsize 38mm(H) x 225mm(W),ofProfab/ OBO/ Neidax.(With all accessories,bend, cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTORas required as per direction of Engg.-in-Charge.(3 COMPARTMENT TOTAL 54 MM HEIGHT. |
| 686 | DATA & TELEPHONE SYSTEM |
| 687 | Data Networking System:-Supply and laying of 4 pair Cat6 U/UTP Cablein the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Tyco / Legrand / Panduit |
| 688 | Supply and Installation of Cat6 I/O with Face plate: The Outlet shall meet or exceed requirementas per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173.The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified.Make: Tyco / Legrand / PanduitI/O Single |
| 689 | Supply and installation of Cat 6, 24-portloaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Tyco / Legrand / Panduit |
| 690 | Supply and installation of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to theStandard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion ,RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts ,100% Factory Tested ,Transparent Boot Cable Assemblies. Make: Tyco / Legrand / Panduit 1mtr Lenghth |
| 691 | Supply and laying of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit:The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm.Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 /ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae )Jacket. Make: Tyco / Legrand / Digisol |
| 692 | Supply, Installation,Testing & Commisioning of 6Port Rack Mount Loaded LIU including SM SC Adaptor and Pigtail. Make: Legrand/Systimax/Panduit |
| 693 | Supply and installation of OFC PATCHCORD, SM (OS2), DUPLEX LC-SC, PC TYPE, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Tyco / Legrand / Digisol |
| 694 | SITC of 9U 600/1000D UL Listed Floor mount Rack with Front glass door with Cam lock, Rear mesh door with Cam lock and 3inch Castor Wheel included with 2 no 6/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Length, 4nos 1U Metal Cable manager with Plastic cable loops, 2nos CFM FAN set, 1no Monitor Tray - Ventilation - 495W - 375D and H/W screw920sets). Make: Valrack/Rittal/ APW |
| 695 | Supplying and fixing ofclip in type modular Telephone socket ISI markedmounted on G.I modular box with face plate & cover of suitable size ,including all accesories and connection as per direction of Engineer in Charge. |
| 696 | Supplying and fixingof clip in type modular T.V. antenna socket ISI marked onmounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge. |
| 697 | Supplying and drawing 4 pair, 0.5 sq.mm FR PVC insulated coper conductor, unarmoured telephone cable in existing surface / recessedPVC conduit as required. |
| 698 | Recessed wiring to television point withcable RG-6 grade, 0.7 mm solid copper conductor PE insulated shielded with fine tined copper braid and protected with FR PVC sheath in in existing surface / recessedPVC conduit as required as per direction of Engineer in Charge. |
| 699 | Supplying and fixing of 16 / 18 SWG metal box of 200 mm x 150 mm x 60 mm deepon surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required.( Tel junction Box) |
| 700 | Supplying & Commissioning of Telephone Hand Set. |
| 701 | Supplying & installationof 50 pair KRONE make moudles with locking & key arrangements fabricated with MS sheet & powder coated to be fixed on concealed manner incl. good the damages. |
| 702 | FIRE FIGHTING |
| 703 | EXTINGUISHER SYSTEM |
| 704 | Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,Carbon di-oxidetype capacity 4.5kg with all accessories (Ever safe/Fire shield/Ceasefire/Safex) |
| 705 | Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,ABC type capacity 6kg with all accessories (Ever safe/Fire shield/Ceasefire/Safex) |
| 706 | Fire buckets (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter \"FIRE\" in black out side and handle with mounting bracket. |
| 707 | SIGNAGES |
| 708 | Floor identification signage (i.e, GROUND FLOOR… ETC.,) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5cm with contrasting colour from back ground. Size shall be 15cm * 60cm. Make-Bajaj/Prolite |
| 709 | Fire Exit signageat each stair on every floor, indicating the direction of fire exit, lettering size shall be 7.5 cm with contrasting color from back ground. Size shall be 15cm x 45cm.Make-Bajaj/Prolite |
| 710 | Providing and fixing in position the signage of \" Fire Extinguisher \" to be fixed above the every extinguisher.Size 6\" x 8\"Make-Bajaj/Prolite |
| 711 | EXTERNAL LIGHTING SYSTEM |
| 712 | Supplying, Erection, Fixing, connection & testing of LED BOUNDRY WALLLight of elegant look (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) 35 W LED street light having die cast aluminium housing with toughened glasshaving lumen efficacy of 110 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 65 protection or more , LED street lightmodel having warrantied for a period of 5 years .The luminaire should be supplied along with bracketmaintenance free for inspection as required as per direction of Engg.-in-Charge. |
| 713 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 714 | LIGHTENING PROTECION SYSTEM |
| 715 | Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn |
| 716 | Supply of Roof conductor holder for parapet- Polyamide Conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561.as per direction of engineer in charge.Make-OBO/Dehn |
| 717 | Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn |
| 718 | Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn |
| 719 | Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn |
| 720 | Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn |
| 721 | Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn |
| 722 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn |
| 723 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. Make-OBO/Dehn |
| 724 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn |
| 725 | Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn |
| 726 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn |
| 727 | Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn |
| 728 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn |
| 729 | Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn |
| 730 | Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn |
| 731 | Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn |
| 732 | Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn |
| 733 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 734 | ADMINISTRATIVE |
| 735 | INTERNAL |
| 736 | Sub-Head I (modular Wiring Items) |
| 737 | Recessed wirring tolight point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI markedMake- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEIwith 20 mm dia HMS FRLS PVCconduitISI markedMake-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type)switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 738 | GROUP-A |
| 739 | GROUP-B |
| 740 | GROUP-C |
| 741 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision).(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 742 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type))with suitable size modular box & cover( flame retradant type) including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius ) /Panasonic (vision).(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 yearsagainst manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 743 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type))with suitable size modular box & cover( flame retradant type) including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision)(For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 744 | Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6Aswitch & socket(modular type) ( ( flame retradant type) with suitable size modular box & metallic cover plate (both side)( flame retradant type)including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius )/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 745 | Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos6Aswitch & socket(modular type) ( ( flame retradant type) with suitable size modular box & metallic cover plate (both side)( flame retradant type)including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 746 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSinsulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI inrecessed HMS FRLS PVCconduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallicheavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 747 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSinsulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI inrecessed HMS FRLS PVCconduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallicheavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 748 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSinsulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI inrecessed HMS FRLS PVCconduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallicheavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 749 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSinsulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI inrecessed HMS FRLS PVCconduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallicheavy dutyconduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5) |
| 750 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSinsulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI inrecessed HMS FRLS PVCconduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32mm dia non metallicheavy dutyconduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4) |
| 751 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSinsulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI inrecessed HMS FRLS PVCconduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallicheavy dutyconduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6) |
| 752 | Supplying and installation of 25A AC starter Modular type, Schneider/Siemens/Legrand coil voltage-230 Volt A.C.on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 753 | Supply and fixingCALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor , A catagory ISI marked as approved .as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 754 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling roseas per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 755 | S/F of 5 step typeModular electronic Fan RegulatorISI Marked with all connection completein all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 756 | Sub-Head II (Light fitting Fixture & Fan) |
| 757 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Orient/Bajaj) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 758 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. |
| 759 | Supplying and fixing of Energy efficient Recess /Surface mounted square/round shaped LED luminaire made up of CRCA powder coatedsheet steelof 36W (595X595X70MM)and system lumens output not less than 4680lumens (130 lm/ wt)withdiffusers for better light transmission and pure effect with High luminous flux LEDs for better light output, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV,complete with Non integrated isolated electronic driver(protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty)supply .as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5 years. |
| 760 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaireof dimension of consists ofwhite powder coated , die-castAlluminiumhousingwith high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not lessthan 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operationon 220 V to 240 Vsupply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 761 | SITC of energy efficient LED tube light fittings with decorative alluminiumbatten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories withdiffuser having 2 years warrantyi/c connection etc as requiredas per direction of Engg.-in-Charge.(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 762 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 763 | Supply and fixing of 10 WattLED BH Fitting (panasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro/Halonix/Orient.) |
| 764 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 765 | BDBS,DB,AC DB,FLOOR PANELS,MCBS |
| 766 | Supplying and fixing of following mentionedway, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9as per direction of Engg.-in-Charge. The Distribution boardsshould be Replacement Warranty will be 3 years. |
| 767 | 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 768 | Supply and fixing of 12 wayDD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years |
| 769 | 2+4 way MCB EnclosureDB (GLAZEDdoor)(only each EM. CONNECTION UPS LOAD)Warranty on DB is 3 years |
| 770 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9.the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on MCB is 3 years. |
| 771 | Supplying and fixing 40 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. TheMCBshould be Replacement Warranty will be 3 years.. |
| 772 | Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 4P, 415 volts, RCCB 30mA .Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . TheMCBshould be Replacement Warranty will be 3 years. |
| 773 | Supplying and fixing 6-32Amps rating,C series,10KA breaking capacity, DP 240 volts, MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge.TheMCBshould be Replacement Warranty will be 3 years. |
| 774 | Supplying and fixing 40Amps rating,C series,10KA breaking capacity, DP 240 volts, MCBMake-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge. TheMCBshould be Replacement Warranty will be 3 years. |
| 775 | Supplying and fixing 40Amps 2P 240 volts RCCB 30 mAMake-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCBshould be Replacement Warranty will be 3 years. |
| 776 | Supplying and fixing 63Amps rating,C series,10KA breaking capacity, 4P 415 volts MCBMake-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCBshould be Replacement Warranty will be 3 years. |
| 777 | Supplying and fixing 63Amps 4P 415 volts RCCB 30 mAMake-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCBshould be Replacement Warranty will be 3 years. |
| 778 | (Earthing) INSTALLATION |
| 779 | S/IT/C of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked withG. I. nutbolts& washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing systemshould be Replacement Warranty will be 2 years |
| 780 | Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge. |
| 781 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 782 | CABLINGAND END TERMINATIONMAIN AREA |
| 783 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE propertyAL. conductor power cable of 1.1 KV gradeMake- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI of following size cables as per direction of Engg.-in-Charge.Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 784 | 4core x 16 sq mm |
| 785 | 4 core x 6 sq mm (for small power) |
| 786 | 3.5core x 50 sq mm |
| 787 | LAYINGOF CABLE |
| 788 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMdirect in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 789 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade sizeexceeding 25 SQ. MMbut not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 790 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMdirect in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 791 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade sizeexceeding 25 SQ. MMbut not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 792 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMin open duct etc as required as per direction of Engg.-in -charge. |
| 793 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade sizeexceeding 25 SQ. MMin open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 794 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMin surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 795 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 796 | Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 797 | 4 core x16sq mm |
| 798 | 3.5 core x50 sq mm |
| 799 | 3.5 core x95 sq mm |
| 800 | Providing,fixing and laying offollowing dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 801 | 50 mm dia |
| 802 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete withfitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 803 | 200 mm dia |
| 804 | PANELS |
| 805 | MAIN CONTROLPANEL AT GF |
| 806 | S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed asG.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessoriesmust be 3 years & compelete test certificate must be submitted along with panel board including component list.Separate Aluminium Earth bus bar should be installed. |
| 807 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W)of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Traysshould be minimum of104.8Kg/meter at the span of1.5Meter as per UL specificationsas required as per direction of Engg.-in-Charge. |
| 808 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W)of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Traysshould be minimum of104.8Kg/meter at the span of1.5Meter as per UL specificationsas required as per direction of Engg.-in-Charge. |
| 809 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 400mm(W)of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Traysshould be minimum of104.8Kg/meter at the span of1.5Meter as per UL specificationsas required as per direction of Engg.-in-Charge. |
| 810 | Supplying,fixing ofFLOOR RACE WAY WITH JUNCTION box GALVANIZED(GC) typeAS PER EN-ISO-1461 , with internal dimensions ofsize 38mm(H) x 225mm(W),ofProfab/ OBO/ Neidax.(With all accessories,bend, cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTORas required as per direction of Engg.-in-Charge.(3 COMPARTMENT TOTAL 54 MM HEIGHT. |
| 811 | DATA & TELEPHONE SYSTEM |
| 812 | Data Networking System:-Supply and laying of 4 pair Cat6 U/UTP Cablein the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Tyco / Legrand / Panduit |
| 813 | Supply and Installation of Cat6 I/O with Face plate: The Outlet shall meet or exceed requirementas per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173.The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified.Make: Tyco / Legrand / PanduitI/O Single |
| 814 | Supply and installation of Cat 6, 24-portloaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Tyco / Legrand / Panduit |
| 815 | Supply and installation of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to theStandard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion ,RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts ,100% Factory Tested ,Transparent Boot Cable Assemblies. Make: Tyco / Legrand / Panduit 1mtr Lenghth |
| 816 | Supply and installation of6x 10/100/1000 Ethernet L2 Fully Managed Switch with ,370 watt poe4x 1/10G SFP uplinks. Switch should support 802.1Q VLAN, MSTP, L2 & L3 ACLs with Dedicated USB managed ports.Make: Cisco/Digisol/HP |
| 817 | Supply and laying of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit:The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm.Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 /ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae )Jacket. Make: Tyco / Legrand / Digisol |
| 818 | Supply, Installation,Testing & Commisioning of 6Port Rack Mount Loaded LIU including SM SC Adaptor and Pigtail. Make: Legrand/Systimax/Panduit |
| 819 | Supply and installation of OFC PATCHCORD, SM (OS2), DUPLEX LC-SC, PC TYPE, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Tyco / Legrand / Digisol |
| 820 | Supplying and fixing ofclip in type modular Telephone socket ISI markedmounted on G.I modular box with face plate & cover of suitable size ,including all accesories and connection as per direction of Engineer in Charge. |
| 821 | Supplying and fixingof clip in type modular T.V. antenna socket ISI marked onmounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge. |
| 822 | Supplying and drawing 4 pair, 0.5 sq.mm FR PVC insulated coper conductor, unarmoured telephone cable in existing surface / recessedPVC conduit as required. |
| 823 | Recessed wiring to television point withcable RG-6 grade, 0.7 mm solid copper conductor PE insulated shielded with fine tined copper braid and protected with FR PVC sheath in in existing surface / recessedPVC conduit as required as per direction of Engineer in Charge. |
| 824 | Supplying and fixing of 16 / 18 SWG metal box of 200 mm x 150 mm x 60 mm deepon surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required.( Tel junction Box) |
| 825 | Supplying & Commissioning of Telephone Hand Set. |
| 826 | Supplying & installationof 50 pair KRONE make moudles with locking & key arrangements fabricated with MS sheet & powder coated to be fixed on concealed manner incl. good the damages. |
| 827 | FIRE FIGHTING |
| 828 | EXTINGUISHER SYSTEM |
| 829 | Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,Carbon di-oxidetype capacity 4.5kg with all accessories (Ever safe/Fire shield/Ceasefire/Safex) |
| 830 | Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,ABC type capacity 6kg with all accessories (Ever safe/Fire shield/Ceasefire/Safex) |
| 831 | Fire buckets (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter \"FIRE\" in black out side and handle with mounting bracket. |
| 832 | SIGNAGES |
| 833 | Floor identification signage (i.e, GROUND FLOOR… ETC.,) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5cm with contrasting colour from back ground. Size shall be 15cm * 60cm. Make-Bajaj/Prolite |
| 834 | Fire Exit signageat each stair on every floor, indicating the direction of fire exit, lettering size shall be 7.5 cm with contrasting color from back ground. Size shall be 15cm x 45cm.Make-Bajaj/Prolite |
| 835 | Providing and fixing in position the signage of \" Fire Extinguisher \" to be fixed above the every extinguisher.Size 6\" x 8\"Make-Bajaj/Prolite |
| 836 | EXTERNAL LIGHTING SYSTEM |
| 837 | Supplying, Erection, Fixing, connection & testing of LED BOUNDRY WALLLight of elegant look (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) 35 W LED street light having die cast aluminium housing with toughened glasshaving lumen efficacy of 110 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 65 protection or more , LED street lightmodel having warrantied for a period of 5 years .The luminaire should be supplied along with bracketmaintenance free for inspection as required as per direction of Engg.-in-Charge. |
| 838 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 839 | LIGHTENING PROTECION SYSTEM |
| 840 | Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn |
| 841 | Supply of Roof conductor holder for parapet- Polyamide Conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561.as per direction of engineer in charge.Make-OBO/Dehn |
| 842 | Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn |
| 843 | Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn |
| 844 | Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn |
| 845 | Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn |
| 846 | Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn |
| 847 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn |
| 848 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. Make-OBO/Dehn |
| 849 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn |
| 850 | Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn |
| 851 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn |
| 852 | Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn |
| 853 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn |
| 854 | Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn |
| 855 | Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn |
| 856 | Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn |
| 857 | Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn |
| 858 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 859 | 1R QUARTER |
| 860 | Sub-Head I (modular Wiring Items) |
| 861 | Recessed wirring tolight point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor (Make-Havells/Polycab/Finolex/RR Kable ) of ISI markedwith 20 mm dia PVC heavy class FRLS non metallic conduit(Make-AKG/Polycab/precision/norpack/sudhakar) with 6A modular type switch(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) )ISI marked , and ceiling rose ISI markedof modular type G.I box with cover , of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection .Raw power supply switch board shall be separate from emergency power supply switchboard as per direction of Engineer -in -Charge.Each light point should have provision for ceiling rose & angle holder point. |
| 862 | GROUP-A(QTRS) |
| 863 | GROUP-B(QTRS) |
| 864 | GROUP-C(COMMON ARAE) |
| 865 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. |
| 866 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision)with suitable size modular box & cover including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge. |
| 867 | Supplying,fixing of 16A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision)with suitable size modular box & cover including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge. |
| 868 | Receass wiring for circuit/submain wiring with the following mentioned size PVC insulated, copper conductor FRLS, single core cable (Make-Havells/Polycab/Finolex/RR Kable or equievalant) inrecessed PVC conduit HEAVY duty (Make-AKG/Polycab/precision/norpack/sudhakar)of mentioned sizeas approved) as required as per direction of Engg.-in-Charge.. |
| 869 | 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic FRLS heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 870 | 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic FRLS heavy duty PVC conduit.(BDB to LSB/LIGHT CKT/5A PLUG/INVERTER POINT TO EACH QTR) (2X2.5+1X1.5) |
| 871 | 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic FRLS heavy duty PVC conduit . (2X4+1X1.5) |
| 872 | 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic FRLS heavy duty PVC conduit .(PANEL TO BDB EACH QTR) (2X6+1X2.5) |
| 873 | Supplying and fixing of following sizes of heavy class FRLS PVC conduit (Make-AKG/Polycab/precision/norpack/sudhakar) along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .(For TV/Internet cable /Fire detection only) |
| 874 | 20 MM |
| 875 | Supplying and installation of 25A AC starter Modular type or any other equivalent reputed make as approved coil voltage-415 Volt A.C. & O/L range of suitable range range on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .(Make-Legrand/Schneider/ Havells/Hagar/ABB/C&S /Panasonic) |
| 876 | Supply and fixingCALL bell (Ding dong type) /Buzzer on the existing switch box/cover. as required as per direction of Engg.-in-Charge. (Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) |
| 877 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells of ISI marked conforming to IS-1258/1987 in place of ceiling roseas per direction of Engg.-in-Charge . |
| 878 | S/F of 5 step typeModular electronic Fan RegulatorISI Marked with all connection completein all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 879 | Sub-Head II (Light fitting Fixture & Fan) |
| 880 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep with louversany other equivalent reputed make star rated as approved) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge.Make-Havells/Bajaj/Usha/Crompton |
| 881 | Supplying, installation, testing and commssioning of 1200 mm sweep BLDC ceiling fan with aluminium blades having wattage not more than 28W and Air delivery ≥ 215(m3/min) Make-USHA(Teohnix)/Crompton(Energion Groove)/Havells(Efficiencia Neo ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. . |
| 882 | SITC of energy efficient LED tube light fittings with decorative alumunium LEDbatten along with LED tube light having power rating20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories withdiffuser i/c connection etc as required. panasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro |
| 883 | SITC of Sleek LED 10 watt mirror light fittingwith decorative aluminium LED batten having extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.panasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro |
| 884 | SITC of Sleek LED 9 watt LED Lamp complete with all accessories etc. directly on angle holderas required.panasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro/Halonix/Orient |
| 885 | Supply and fixing of 10 WattLED BH Fitting (panasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro) |
| 886 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 887 | Supplying, Erection, Fixing, connection & testing of LED street lightwith moveableG.Ibracket &G.I Flat clamp ,90 W LEDhaving die cast aluminium housing with toughened glasshaving lumen efficacy of 120 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 66 protection or more , LED street light .make-wipro/philips/Havells/Bajaj/panasonic .The luminaire should be supplied along with bracketmaintenance free for inspection as required,wired by 1.5 sq. mm FRLS wire /cable along with earth wireas per direction of Engg.-in-Charge. |
| 888 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaireof dimension of consists ofwhite powder coated , die-castAlluminiumhousingwith high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not lessthan 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operationon 220 V to 240 Vsupply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 5 years |
| 889 | BDBS,DB,AC DB,FLOOR PANELS,MCBS |
| 890 | Supplying and fixing of following mentionedway, three pole/single pole and neutral, 1.6 mm thicknesssheet steel,double door MCB distribution board, 415 volts/240 volts, on surface/recess, complete with terminal blocks, duly prewired with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. , or any other equivallent A catagories reputed make ISI marked as approvedas per direction of Engg.-in-Charge. make-Legrand-Ekinox3/schneider-Acti-9/Siemens-Betaguard/Eq. model of ABB/Hagar/LK/Havells/C&S/Panasonic |
| 891 | Supply and fixing of 8 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years (For Inverter and Servant quarters,1 no for lift) |
| 892 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/eq. Model of ABB/LK/Hager/C&S/Havells/Panasonic.the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on MCB is 3 years. |
| 893 | Supplying and fixing 63 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA .Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/eq. Model of ABB/LK/Hager/C&S/Havells/Panasonic in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . TheRCCBshould be Replacement Warranty will be 3 years. |
| 894 | Supplying and fixing 25 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA .Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/eq. Model of ABB/LK/Hager/C&S/Havells/Panasonic in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . TheRCCBshould be Replacement Warranty will be 3 years. |
| 895 | (Earthing) INSTALLATION |
| 896 | S/IT/C Of Earthing withG.I earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITHcharcoal and salt) as required as per direction of Engg.-in-Charge.The entire earthing systemshould be Replacement Warranty will be 2 years |
| 897 | Providing and fixing 6 SWG G.I wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge. |
| 898 | Providing and fixing 25mm x 5 mm G.I strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.(DOUBLE RUN TO MAIN PANEL & APFC PANEL ,AC PANEL) |
| 899 | CABLINGAND END TERMINATIONMAIN AREA |
| 900 | Supplying of one number PVC insulated armoured and PVC sheathed AL. conductor power cable of 1.1 KV grade of following size cables as per direction of Engg.-in-Charge. make-polycab/finolex/Havells/RR Kabel/KEI |
| 901 | 4core x 16 sq mm |
| 902 | LAYINGOF CABLE |
| 903 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMdirect in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 904 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMin surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 905 | Supplying and making end termination with brass comprecision gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 906 | 4core x 16 sq mm |
| 907 | Providing,fixing and laying of fallowing dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 908 | 50 mm dia |
| 909 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials(MAKE- Finolex/polycab) |
| 910 | PANELS |
| 911 | MAIN METERING PANEL |
| 912 | S/I/T&Commissioning of LT indoor floor mounted cubical typeMETERING electrical main panel (for QTR) made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed asG.A drawing as per direction of Engg.-in-Charge. 40x10mm Separate Aluminium Earth bus bar is to be provided. |
| 913 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W)of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Traysshould be minimum of104.8Kg/meter at the span of1.5Meter as per UL specificationsas required as per direction of Engg.-in-Charge. |
| 914 | FIRE FIGHTING |
| 915 | EXTINGUISHER SYSTEM |
| 916 | Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,Carbon di-oxidetype capacity 4.5kg with all accessories (Ever safe/Fire shield/Ceasefire/Safex) |
| 917 | Fire buckets (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter \"FIRE\" in black out side and handle with mounting bracket. |
| 918 | SIGNAGES |
| 919 | Floor identification signage (i.e, GROUND FLOOR… ETC.,) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5cm with contrasting colour from back ground. Size shall be 15cm * 60cm. Make-Bajaj/Prolite |
| 920 | Fire Exit signageat each stair on every floor, indicating the direction of fire exit, lettering size shall be 7.5 cm with contrasting color from back ground. Size shall be 15cm x 45cm.Make-Bajaj/Prolite |
| 921 | Providing and fixing in position the signage of \" Fire Extinguisher \" to be fixed above the every extinguisher.Size 6\" x 8\"Make-Bajaj/Prolite |
| 922 | LIGHTENING PROTECION SYSTEM |
| 923 | Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn |
| 924 | Supply of Roof conductor holder for parapet- PolyamideConductor holder:With M8 female thread or diameter 7mm, M8Screw to connect the conductor holder.Weather andtemperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter distance.Tested as per IEC 62561.as per direction of engineer in charge.Make-OBO/Dehn |
| 925 | Supply of Polyamide roof cable holder for flat roof:DIN 48829 Form B1. Closed form with bottom. Filling weight1Kg (frost-resistant concrete). Sleeve from polyethylene, black@ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn |
| 926 | Supply of Connector: For T cross and parallel connectors. Quickinstallation using hexagonal bolt M10X30 high-grade hot dipgalvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn |
| 927 | Supply of 1 mtr vertical air terminal with mounting accessorieson the flat surface to meet the requirements of IS/IEC 62305.Tested for Electrical , mechanical and chemical as per IEC62561. Tested for 100kA lightning current. Make-OBO/Dehn |
| 928 | Supply of Vertical air terminal with accessories:Providing of Air terminalsas per IS-IEC -62305 part-3Nominal size Ø10/16 mm aluminium rod:3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN48801) Suitable for high wind load.Tested as per IEC 62561. Make-OBO/Dehn |
| 929 | Supply for Providing of Stand for Fang Fix system 16 kg with base andclamp ,made up of frost resistant concrete and clamp testedupto 100KA lightning current . Make-OBO/Dehn |
| 930 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frostresistant concrete. Make-OBO/Dehn |
| 931 | Supply of Test Joint (Folding Clamp) suitable to connect 8mmround conductor and max by 30x3 mm GI strip as specified indrawing and directed by Engineer.Tested for 100kA lightning current. Make-OBO/Dehn |
| 932 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr HeightFor Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn |
| 933 | Supply of Galvanised Steel Flat 30X3 mm thickness from earthelectrode directly in ground as required. Flat conductor HotDipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn |
| 934 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn |
| 935 | Supply of flat conductor holder- Fit: FL 30, With mounting hole6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece fromhot-dip galvanised steel, Bottom section from polyamide, black.Tested as per IEC 62561. Make-OBO/Dehn |
| 936 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn |
| 937 | Supply of UL Listed maintenance free ,Low carbon coppercoated earth rod of 3 metre electrode having diameter of 17.2mm with copper coating thickness of 250micron tested as perIEC 62561-2 Make-OBO/Dehn |
| 938 | Supply of universal clamp made of SS to connect rod with flatconductor Make-OBO/Dehn |
| 939 | Supply of Earth conductivity enhancing mineral compound shall be of 25kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn |
| 940 | Supply of The above arrangements shall be provided with Heavy dutyearth champer of 5000kg load bearing capacity to ensure thesafety of earthing system Make-OBO/Dehn |
| 941 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 942 | 3R QUARTERS |
| 943 | Sub-Head I (modular Wiring Items) |
| 944 | Recessed wirring tolight point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor (Make-Havells/Polycab/Finolex/RR Kable ) of ISI markedwith 20 mm dia PVC heavy class FRLS non metallic conduit(Make-AKG/Polycab/precision/norpack/sudhakar) with 6A modular type switch(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) )ISI marked , and ceiling rose ISI markedof modular type G.I box with cover , of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection .Raw power supply switch board shall be separate from emergency power supply switchboard as per direction of Engineer -in -Charge.Each light point should have provision for ceiling rose & angle holder point. |
| 945 | GROUP-A(QTRS) |
| 946 | GROUP-B(QTRS) |
| 947 | GROUP-C(COMMON ARAE) |
| 948 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. |
| 949 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision)with suitable size modular box & cover including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge. |
| 950 | Supplying,fixing of 16A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision)with suitable size modular box & cover including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge. |
| 951 | Receass wiring for circuit/submain wiring with the following mentioned size PVC insulated, copper conductor FRLS, single core cable (Make-Havells/Polycab/Finolex/RR Kable or equievalant) inrecessed PVC conduit HEAVY duty (Make-AKG/Polycab/precision/norpack/sudhakar)of mentioned sizeas approved) as required as per direction of Engg.-in-Charge.. |
| 952 | 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic FRLS heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 953 | 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic FRLS heavy duty PVC conduit.(BDB to LSB/LIGHT CKT/5A PLUG/INVERTER POINT TO EACH QTR) (2X2.5+1X1.5) |
| 954 | 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic FRLS heavy duty PVC conduit . (2X4+1X1.5) |
| 955 | 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic FRLS heavy duty PVC conduit .(PANEL TO BDB EACH QTR) (2X6+1X2.5) |
| 956 | Supplying and fixing of following sizes of heavy class FRLS PVC conduit (Make-AKG/Polycab/precision/norpack/sudhakar) along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .(For TV/Internet cable /Fire detection only) |
| 957 | 20 MM |
| 958 | Supplying and installation of 25A AC starter Modular type or any other equivalent reputed make as approved coil voltage-415 Volt A.C. & O/L range of suitable range range on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .(Make-Legrand/Schneider/ Havells/Hagar/ABB/C&S /Panasonic) |
| 959 | Supply and fixingCALL bell (Ding dong type) /Buzzer on the existing switch box/cover. as required as per direction of Engg.-in-Charge. (Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) |
| 960 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells of ISI marked conforming to IS-1258/1987 in place of ceiling roseas per direction of Engg.-in-Charge . |
| 961 | S/F of 5 step typeModular electronic Fan RegulatorISI Marked with all connection completein all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 962 | Sub-Head II (Light fitting Fixture & Fan) |
| 963 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep with louversany other equivalent reputed make star rated as approved) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge.Make-Havells/Bajaj/Usha/Crompton |
| 964 | Supplying, installation, testing and commssioning of 1200 mm sweep BLDC ceiling fan with aluminium blades having wattage not more than 28W and Air delivery ≥ 215(m3/min) Make-USHA(Teohnix)/Crompton(Energion Groove)/Havells(Efficiencia Neo ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. . |
| 965 | SITC of energy efficient LED tube light fittings with decorative alumunium LEDbatten along with LED tube light having power rating20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories withdiffuser i/c connection etc as required. panasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro |
| 966 | SITC of Sleek LED 10 watt mirror light fittingwith decorative aluminium LED batten having extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.panasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro |
| 967 | SITC of Sleek LED 9 watt LED Lamp complete with all accessories etc. directly on angle holderas required.panasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro/Halonix/Orient |
| 968 | Supply and fixing of 10 WattLED BH Fitting (panasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro) |
| 969 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 970 | Supplying, Erection, Fixing, connection & testing of LED street lightwith moveableG.Ibracket &G.I Flat clamp ,90 W LEDhaving die cast aluminium housing with toughened glasshaving lumen efficacy of 120 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 66 protection or more , LED street light .make-wipro/philips/Havells/Bajaj/panasonic .The luminaire should be supplied along with bracketmaintenance free for inspection as required,wired by 1.5 sq. mm FRLS wire /cable along with earth wireas per direction of Engg.-in-Charge. |
| 971 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaireof dimension of consists ofwhite powder coated , die-castAlluminiumhousingwith high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not lessthan 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operationon 220 V to 240 Vsupply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 5 years |
| 972 | BDBS,DB,AC DB,FLOOR PANELS,MCBS |
| 973 | Supplying and fixing of following mentionedway, three pole/single pole and neutral, 1.6 mm thicknesssheet steel,double door MCB distribution board, 415 volts/240 volts, on surface/recess, complete with terminal blocks, duly prewired with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. , or any other equivallent A catagories reputed make ISI marked as approvedas per direction of Engg.-in-Charge. make-Legrand-Ekinox3/schneider-Acti-9/Siemens-Betaguard/Eq. model of ABB/Hagar/LK/Havells/C&S/Panasonic |
| 974 | Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years .(QTR & COMMON) |
| 975 | Supply and fixing of 8 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years (For Inverter and Servant quarters,1 no for lift) |
| 976 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/eq. Model of ABB/LK/Hager/C&S/Havells/Panasonic.the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on MCB is 3 years. |
| 977 | Supplying and fixing 63 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA .Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/eq. Model of ABB/LK/Hager/C&S/Havells/Panasonic in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . TheRCCBshould be Replacement Warranty will be 3 years. |
| 978 | Supplying and fixing 25 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA .Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/eq. Model of ABB/LK/Hager/C&S/Havells/Panasonic in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . TheRCCBshould be Replacement Warranty will be 3 years. |
| 979 | Supplying and fixing 25 amps rating, 415 volts, C series,10KA breaking capacity, FOUR poles MCB ofMake-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/eq. Model of ABB/LK/Hager/C&S/Havells/Panasonic in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on MCB is 3 years. |
| 980 | Supplying and fixing 32 amps rating, 400 volts AC, double poles MCB changeover with 3 position incorporating center off ofMake-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/eq. Model of ABB/LK/Hager/C&S/Havells/Panasonic in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on MCB is 3 years. |
| 981 | (Earthing) INSTALLATION |
| 982 | S/IT/C Of Earthing withG.I earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITHcharcoal and salt) as required as per direction of Engg.-in-Charge.The entire earthing systemshould be Replacement Warranty will be 2 years |
| 983 | Providing and fixing 6 SWG G.I wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge. |
| 984 | Providing and fixing 25mm x 5 mm G.I strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.(DOUBLE RUN TO MAIN PANEL & APFC PANEL ,AC PANEL) |
| 985 | CABLINGAND END TERMINATIONMAIN AREA |
| 986 | Supplying of one number PVC insulated armoured and PVC sheathed AL. conductor power cable of 1.1 KV grade of following size cables as per direction of Engg.-in-Charge. make-polycab/finolex/Havells/RR Kabel/KEI |
| 987 | 4core x 16 sq mm |
| 988 | LAYINGOF CABLE |
| 989 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMdirect in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 990 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMin surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 991 | Supplying and making end termination with brass comprecision gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 992 | 4core x 16 sq mm |
| 993 | Providing,fixing and laying of fallowing dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 994 | 50 mm dia |
| 995 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials(MAKE- Finolex/polycab) |
| 996 | PANELS |
| 997 | MAIN METERING PANEL |
| 998 | S/I/T&Commissioning of LT indoor floor mounted cubical typeMETERING electrical main panel (for QTR) made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed asG.A drawing as per direction of Engg.-in-Charge. 40x10mm Separate Aluminium Earth bus bar is to be provided. |
| 999 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W)of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Traysshould be minimum of104.8Kg/meter at the span of1.5Meter as per UL specificationsas required as per direction of Engg.-in-Charge. |
| 1000 | FIRE FIGHTING |
| 1001 | EXTINGUISHER SYSTEM |
| 1002 | Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,Carbon di-oxidetype capacity 4.5kg with all accessories (Ever safe/Fire shield/Ceasefire/Safex) |
| 1003 | Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,ABC type capacity 6kg with all accessories (Ever safe/Fire shield/Ceasefire/Safex) |
| 1004 | Fire buckets (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter \"FIRE\" in black out side and handle with mounting bracket. |
| 1005 | SIGNAGES |
| 1006 | Floor identification signage (i.e, GROUND FLOOR… ETC.,) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5cm with contrasting colour from back ground. Size shall be 15cm * 60cm. Make-Bajaj/Prolite |
| 1007 | Fire Exit signageat each stair on every floor, indicating the direction of fire exit, lettering size shall be 7.5 cm with contrasting color from back ground. Size shall be 15cm x 45cm.Make-Bajaj/Prolite |
| 1008 | Providing and fixing in position the signage of \" Fire Extinguisher \" to be fixed above the every extinguisher.Size 6\" x 8\"Make-Bajaj/Prolite |
| 1009 | LIGHTENING PROTECION SYSTEM |
| 1010 | Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn |
| 1011 | Supply of Roof conductor holder for parapet- PolyamideConductor holder:With M8 female thread or diameter 7mm, M8Screw to connect the conductor holder.Weather andtemperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter distance.Tested as per IEC 62561.as per direction of engineer in charge.Make-OBO/Dehn |
| 1012 | Supply of Polyamide roof cable holder for flat roof:DIN 48829 Form B1. Closed form with bottom. Filling weight1Kg (frost-resistant concrete). Sleeve from polyethylene, black@ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn |
| 1013 | Supply of Connector: For T cross and parallel connectors. Quickinstallation using hexagonal bolt M10X30 high-grade hot dipgalvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn |
| 1014 | Supply of 1 mtr vertical air terminal with mounting accessorieson the flat surface to meet the requirements of IS/IEC 62305.Tested for Electrical , mechanical and chemical as per IEC62561. Tested for 100kA lightning current. Make-OBO/Dehn |
| 1015 | Supply of Vertical air terminal with accessories:Providing of Air terminalsas per IS-IEC -62305 part-3Nominal size Ø10/16 mm aluminium rod:3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN48801) Suitable for high wind load.Tested as per IEC 62561. Make-OBO/Dehn |
| 1016 | Supply for Providing of Stand for Fang Fix system 16 kg with base andclamp ,made up of frost resistant concrete and clamp testedupto 100KA lightning current . Make-OBO/Dehn |
| 1017 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frostresistant concrete. Make-OBO/Dehn |
| 1018 | Supply of Test Joint (Folding Clamp) suitable to connect 8mmround conductor and max by 30x3 mm GI strip as specified indrawing and directed by Engineer.Tested for 100kA lightning current. Make-OBO/Dehn |
| 1019 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr HeightFor Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn |
| 1020 | Supply of Galvanised Steel Flat 30X3 mm thickness from earthelectrode directly in ground as required. Flat conductor HotDipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn |
| 1021 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn |
| 1022 | Supply of flat conductor holder- Fit: FL 30, With mounting hole6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece fromhot-dip galvanised steel, Bottom section from polyamide, black.Tested as per IEC 62561. Make-OBO/Dehn |
| 1023 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn |
| 1024 | Supply of UL Listed maintenance free ,Low carbon coppercoated earth rod of 3 metre electrode having diameter of 17.2mm with copper coating thickness of 250micron tested as perIEC 62561-2 Make-OBO/Dehn |
| 1025 | Supply of universal clamp made of SS to connect rod with flatconductor Make-OBO/Dehn |
| 1026 | Supply of Earth conductivity enhancing mineral compound shall be of 25kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn |
| 1027 | Supply of The above arrangements shall be provided with Heavy dutyearth champer of 5000kg load bearing capacity to ensure thesafety of earthing system Make-OBO/Dehn |
| 1028 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 1029 | Recessed wirring tolight point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI markedMake- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEIwith 20 mm dia HMS FRLS PVCconduitISI markedMake-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type)switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 1030 | GROUP-A |
| 1031 | GROUP-B |
| 1032 | GROUP-C |
| 1033 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision).(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 1034 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type))with suitable size modular box & cover( flame retradant type) including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius ) /Panasonic (vision).(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 yearsagainst manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 1035 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type))with suitable size modular box & cover( flame retradant type) including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision)(For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 1036 | Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6Aswitch & socket(modular type) ( ( flame retradant type) with suitable size modular box & metallic cover plate (both side)( flame retradant type)including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius )/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 1037 | Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos6Aswitch & socket(modular type) ( ( flame retradant type) with suitable size modular box & metallic cover plate (both side)( flame retradant type)including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 1038 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSinsulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI inrecessed HMS FRLS PVCconduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallicheavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 1039 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSinsulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI inrecessed HMS FRLS PVCconduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallicheavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 1040 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSinsulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI inrecessed HMS FRLS PVCconduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallicheavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 1041 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSinsulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI inrecessed HMS FRLS PVCconduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallicheavy dutyconduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5) |
| 1042 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSinsulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI inrecessed HMS FRLS PVCconduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32mm dia non metallicheavy dutyconduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4) |
| 1043 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSinsulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI inrecessed HMS FRLS PVCconduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallicheavy dutyconduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6) |
| 1044 | Supply and fixingCALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor , A catagory ISI marked as approved .as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 1045 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling roseas per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 1046 | S/F of 5 step typeModular electronic Fan RegulatorISI Marked with all connection completein all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 1047 | Sub-Head II (Light fitting Fixture & Fan) |
| 1048 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Orient/Bajaj) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 1049 | Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 1050 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. |
| 1051 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaireof dimension of consists ofwhite powder coated , die-castAlluminiumhousingwith high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not lessthan 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operationon 220 V to 240 Vsupply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 1052 | SITC of energy efficient LED tube light fittings with decorative alluminiumbatten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories withdiffuser having 2 years warrantyi/c connection etc as requiredas per direction of Engg.-in-Charge.(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 1053 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 1054 | Supply and fixing of 10 WattLED BH Fitting (panasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro/Halonix/Orient.) |
| 1055 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 1056 | BDBS,DB,AC DB,FLOOR PANELS,MCBS |
| 1057 | Supplying and fixing of following mentionedway, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9as per direction of Engg.-in-Charge. The Distribution boardsshould be Replacement Warranty will be 3 years. |
| 1058 | 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 1059 | Supply and fixing of 12 wayDD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years |
| 1060 | 2+4 way MCB EnclosureDB (GLAZEDdoor)(only each EM. CONNECTION UPS LOAD)Warranty on DB is 3 years |
| 1061 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9.the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on MCB is 3 years. |
| 1062 | Supplying and fixing 40 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. TheMCBshould be Replacement Warranty will be 3 years.. |
| 1063 | Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 4P, 415 volts, RCCB 30mA .Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . TheMCBshould be Replacement Warranty will be 3 years. |
| 1064 | Supplying and fixing 6-32Amps rating,C series,10KA breaking capacity, DP 240 volts, MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge.TheMCBshould be Replacement Warranty will be 3 years. |
| 1065 | Supplying and fixing 40Amps rating,C series,10KA breaking capacity, DP 240 volts, MCBMake-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge. TheMCBshould be Replacement Warranty will be 3 years. |
| 1066 | Supplying and fixing 40Amps 2P 240 volts RCCB 30 mAMake-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCBshould be Replacement Warranty will be 3 years. |
| 1067 | Supplying and fixing 63Amps rating,C series,10KA breaking capacity, 4P 415 volts MCBMake-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCBshould be Replacement Warranty will be 3 years. |
| 1068 | Supplying and fixing 63Amps 4P 415 volts RCCB 30 mAMake-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCBshould be Replacement Warranty will be 3 years. |
| 1069 | (Earthing) INSTALLATION |
| 1070 | S/IT/C of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked withG. I. nutbolts& washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing systemshould be Replacement Warranty will be 2 years |
| 1071 | Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge. |
| 1072 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 1073 | CABLINGAND END TERMINATIONMAIN AREA |
| 1074 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE propertyAL. conductor power cable of 1.1 KV gradeMake- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI of following size cables as per direction of Engg.-in-Charge.Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 1075 | 4core x 16 sq mm |
| 1076 | 4 core x 6 sq mm (for small power) |
| 1077 | 3.5core x 50 sq mm |
| 1078 | LAYINGOF CABLE |
| 1079 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMdirect in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 1080 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade sizeexceeding 25 SQ. MMbut not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 1081 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMdirect in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 1082 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade sizeexceeding 25 SQ. MMbut not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 1083 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMin open duct etc as required as per direction of Engg.-in -charge. |
| 1084 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade sizeexceeding 25 SQ. MMin open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 1085 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMin surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 1086 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 1087 | Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 1088 | 4 core x16sq mm |
| 1089 | 3.5 core x50 sq mm |
| 1090 | Providing,fixing and laying offollowing dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 1091 | 50 mm dia |
| 1092 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete withfitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 1093 | 200 mm dia |
| 1094 | PANELS |
| 1095 | MAIN CONTROLPANEL AT GF |
| 1096 | S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed asG.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessoriesmust be 3 years & compelete test certificate must be submitted along with panel board including component list.Separate Aluminium Earth bus bar should be installed. |
| 1097 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W)of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Traysshould be minimum of104.8Kg/meter at the span of1.5Meter as per UL specificationsas required as per direction of Engg.-in-Charge. |
| 1098 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W)of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Traysshould be minimum of104.8Kg/meter at the span of1.5Meter as per UL specificationsas required as per direction of Engg.-in-Charge. |
| 1099 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 400mm(W)of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Traysshould be minimum of104.8Kg/meter at the span of1.5Meter as per UL specificationsas required as per direction of Engg.-in-Charge. |
| 1100 | Supplying,fixing ofFLOOR RACE WAY WITH JUNCTION box GALVANIZED(GC) typeAS PER EN-ISO-1461 , with internal dimensions ofsize 38mm(H) x 225mm(W),ofProfab/ OBO/ Neidax.(With all accessories,bend, cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTORas required as per direction of Engg.-in-Charge.(3 COMPARTMENT TOTAL 54 MM HEIGHT. |
| 1101 | DATA, TELEPHONE |
| 1102 | Data Networking System:-Supply and laying of 4 pair Cat6 U/UTP Cablein the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Tyco / Legrand / Panduit |
| 1103 | Supply and Installation of Cat6 I/O with Face plate: The Outlet shall meet or exceed requirementas per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173.The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified.Make: Tyco / Legrand / PanduitI/O Single |
| 1104 | Supply and installation of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to theStandard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion ,RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts ,100% Factory Tested ,Transparent Boot Cable Assemblies. Make: Tyco / Legrand / Panduit 1mtr Lenghth |
| 1105 | Supply and laying of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit:The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm.Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 /ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae )Jacket. Make: Tyco / Legrand / Digisol |
| 1106 | Supply, Installation,Testing & Commisioning of 6Port Rack Mount Loaded LIU including SM SC Adaptor and Pigtail. Make: Legrand/Systimax/Panduit |
| 1107 | Supply and installation of OFC PATCHCORD, SM (OS2), DUPLEX LC-SC, PC TYPE, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Tyco / Legrand / Digisol |
| 1108 | Supplying and fixing ofclip in type modular Telephone socket ISI markedmounted on G.I modular box with face plate & cover of suitable size ,including all accesories and connection as per direction of Engineer in Charge. |
| 1109 | Supplying and fixingof clip in type modular T.V. antenna socket ISI marked onmounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge. |
| 1110 | Supplying and drawing 4 pair, 0.5 sq.mm FR PVC insulated coper conductor, unarmoured telephone cable in existing surface / recessedPVC conduit as required. |
| 1111 | Recessed wiring to television point withcable RG-6 grade, 0.7 mm solid copper conductor PE insulated shielded with fine tined copper braid and protected with FR PVC sheath in in existing surface / recessedPVC conduit as required as per direction of Engineer in Charge. |
| 1112 | Supplying and fixing of 16 / 18 SWG metal box of 200 mm x 150 mm x 60 mm deepon surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required.( Tel junction Box) |
| 1113 | Supplying & Commissioning of Telephone Hand Set. |
| 1114 | Supplying & installationof 50 pair KRONE make moudles with locking & key arrangements fabricated with MS sheet & powder coated to be fixed on concealed manner incl. good the damages. |
| 1115 | FIRE FIGHTING |
| 1116 | Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,Carbon di-oxidetype capacity 4.5kg with all accessories (Ever safe/Fire shield/Ceasefire/Safex) |
| 1117 | Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,ABC type capacity 6kg with all accessories (Ever safe/Fire shield/Ceasefire/Safex) |
| 1118 | Fire buckets (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter \"FIRE\" in black out side and handle with mounting bracket. |
| 1119 | SIGNAGES |
| 1120 | Floor identification signage (i.e, GROUND FLOOR… ETC.,) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5cm with contrasting colour from back ground. Size shall be 15cm * 60cm. Make-Bajaj/Prolite |
| 1121 | Fire Exit signageat each stair on every floor, indicating the direction of fire exit, lettering size shall be 7.5 cm with contrasting color from back ground. Size shall be 15cm x 45cm.Make-Bajaj/Prolite |
| 1122 | Providing and fixing in position the signage of \" Fire Extinguisher \" to be fixed above the every extinguisher.Size 6\" x 8\"Make-Bajaj/Prolite |
| 1123 | EXTERNAL LIGHTING SYSTEM |
| 1124 | Supplying, Erection, Fixing, connection & testing of LED BOUNDRY WALLLight of elegant look (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) 35 W LED street light having die cast aluminium housing with toughened glasshaving lumen efficacy of 110 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 65 protection or more , LED street lightmodel having warrantied for a period of 5 years .The luminaire should be supplied along with bracketmaintenance free for inspection as required as per direction of Engg.-in-Charge. |
| 1125 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 1126 | LIGHTENING PROTECION SYSTEM |
| 1127 | Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn |
| 1128 | Supply of Roof conductor holder for parapet- Polyamide Conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561.as per direction of engineer in charge.Make-OBO/Dehn |
| 1129 | Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn |
| 1130 | Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn |
| 1131 | Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn |
| 1132 | Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn |
| 1133 | Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn |
| 1134 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn |
| 1135 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. Make-OBO/Dehn |
| 1136 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn |
| 1137 | Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn |
| 1138 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn |
| 1139 | Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn |
| 1140 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn |
| 1141 | Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn |
| 1142 | Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn |
| 1143 | Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn |
| 1144 | Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn |
| 1145 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 1146 | PH |
| 1147 | ADMINISTRATIVE |
| 1148 | A- Internal PH Work |
| 1149 | Supplying all materials, labour,T&Pand providing and fixing to wall or ceiling and floor ChlorinatedPolyvinyl Chloride (C-PVC) pipes (Make-Astral/Supreme/Finolex) conforming to IS:15778,having thermal stability for hot & cold water supply , including all CPVCplain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes &fittings with one step CPVCsolvent cement and testing of joints complete as per direction of Engineer -in-Charge. |
| 1150 | GroundFloor |
| 1151 | 20mm dia C-PVC pipe |
| 1152 | 25mm dia C-PVC pipe |
| 1153 | 32mm dia C-PVC pipe |
| 1154 | 40mm dia C-PVC pipe |
| 1155 | In 1st Floor |
| 1156 | 25mm dia C-PVC pipe |
| 1157 | 32mm dia C-PVC pipe |
| 1158 | 40mm dia C-PVC pipe |
| 1159 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge. |
| 1160 | 250mmthick wall in Ground floor |
| 1161 | In 1st Floor |
| 1162 | Supplying all materials, labour, T&Pand cutting hole in R.C.C floors, roofs, etc upto 19 cm thickfor passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes afterinsertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of theEngineer in charge.in Ground Floor |
| 1163 | In 1st Floor |
| 1164 | Supplying allmaterials, labour, T&P and cutting grooves in pucca floors and walls for takingGI/ PVC pipes and making good the damages as per the direction of the Engineer in charge. In Ground Floor |
| 1165 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all completeas per PH specification and direction of the Engineer in charge |
| 1166 | 250mm to 375mmthick wall |
| 1167 | in 1st Floor to 5th Floor |
| 1168 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge |
| 1169 | 15mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make) |
| 1170 | 15mm dia CP CP Angle stop cock (Jaquar-Con-CHR-053KN) |
| 1171 | 15mm dia CP extension piece |
| 1172 | 15mm dia CP Pillar cock (Jaquar-Con-CHR-011KN) |
| 1173 | 25mm dia G.M or Brass F.W valve (Sakti make) |
| 1174 | 32mm dia G.M or Brass F.W valve (Sakti make) |
| 1175 | 40mm dia G.M or Brass F.W valve (Sakti make) |
| 1176 | 125mm dia CP gratings |
| 1177 | Supplying all materials, labour, T&P and fitting and fixing 12.50 litres/10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge |
| 1178 | 10 litres PVC L.L. Cistern (Slimline-white) |
| 1179 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering,watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge |
| 1180 | 2000 Ltr PVC water storage tank (3 Layer White)-on 2nd. Floor |
| 1181 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS UV/80 SS UV of size 750x570x1350mm height with water storage capacity 120 liters along with 3 nos of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all completeas per approved drawing,specification and direction of the Engineer in charge. |
| 1182 | Aquaguard cooler cum purifier(Aqualguard pure chill 80 SS UV) |
| 1183 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings (Make-Supreme/Finolex) of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricantby non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge. |
| 1184 | 75mm dia U-PVC SWR pipes |
| 1185 | 75mm U-PVC plain bend |
| 1186 | 110mm dia U-PVC SWR pipes |
| 1187 | 110mm U-PVC door bend |
| 1188 | 110mm U-PVC door Tee |
| 1189 | 110mm U-PVC plain Tee |
| 1190 | 110mm dia U-PVC offset without ear |
| 1191 | 110mm U-PVC plain bend |
| 1192 | 110mm U-PVC vent cowl |
| 1193 | 110mm dia U-PVC \"P\" trap |
| 1194 | 110mm dia U-PVC socket plain |
| 1195 | 75mm dia U-PVC socket plain |
| 1196 | PVC Clamp |
| 1197 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan conforming to IS:2556-part-3-2004) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x 30mm footrest, fixing 100mm dia HCI ‘P’ or ‘S’ trap (with/without 50mm dia horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc all complete as per specification and direction of the Engineer in charge(Nycer,parryware make) |
| 1198 | 580mm size Orissa pan(Hindware/Parryware/Neycer) |
| 1199 | Supplying all materials, labour, T&P and fixing Wash Down Water Closet (European type W.C pan) with integral ‘S’ or ‘P’ trap to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification and direction of the Engineer in charge. |
| 1200 | E.W.C. with seat cover (Parryware/Hindware/Neycer) |
| 1201 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make),etc all complete as per specification and direction of the Engineer in charge |
| 1202 | Under counter basin(Hindware)No.10095+ALD-CHR-709+ALD-CHR-803AB+KUB-35001F |
| 1203 | Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge |
| 1204 | 600mm x 450mm size B.E mirror |
| 1205 | Mirror of best quality of 2100mmx600mm |
| 1206 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 1207 | 600 x 125mm plate glass shelf with CP guard rails( Jaquar -AKP-3577P) |
| 1208 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 1209 | 25mm x 600mm long CP towel rail (Jaquar -ACN-111SM) |
| 1210 | CP towel Ring(Jaquar -ACN-1121N) |
| 1211 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 1212 | CP soap holder( Jaquar -ACN-1131N) |
| 1213 | Supplying all materials labour T&P and filling in foundation and plinth with sandwellwatered and rammed including conveyance of all materials to work sitepayment of royalty taxes etc all complete as per direction ofEngineer in charge In ground floor |
| 1214 | L Toilet1x5.97x4.06x0.30= |
| 1215 | G. Toilet1x5.97x3.48x0.30= |
| 1216 | PWD. Toilet1x3.23x2.40x0.30= |
| 1217 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
| 1218 | L Toilet1x3.75x2.56x0.10= |
| 1219 | G. Toilet1x5.20x2.93x0.10= |
| 1220 | PWD. Toilet1x2.40x2.40x0.10= |
| 1221 | Supply of all materials & laying the waterproofing material of Dr.Fixit torch shield P3160(3mm)with its primer 2 coats or equivalent water proofing material after drying cleaning the concrete surface over the concrete floor/roof/ balcony/sunken and dado upto 1\"6\" in wall including cleaning,applying and mending as per specification including cost,conveyance,taxes,royalities of all materials to work site etc.all complete as per the direction of the Engineer-in-charge.(Sqm) |
| 1222 | In Ist Floor (sunkeen floor) |
| 1223 | L Toilet1x3.75x2.56= |
| 1224 | G. Toilet1x5.20x2.93= |
| 1225 | PWD. Toilet1x2.40x2.40= |
| 1226 | (sunkeen Wall) |
| 1227 | L\" Toilet 1x2x(3.75+2.56)x0.45 |
| 1228 | G\" Toilet 1x2x(5.20+2.93)x0.45 |
| 1229 | PWDToilet 1x2x(2.40+2.40)x0.45 |
| 1230 | Supplying all materials, labour, T&P and providing and filling cynder including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1231 | In First Floor |
| 1232 | L Toilet1x3.75x2.56x0.10= |
| 1233 | G. Toilet1x5.20x2.93x0.10= |
| 1234 | PWD. Toilet1x2.40x2.40x0.10= |
| 1235 | Supplying all materials, labour, T&P and constructing Gully Trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, Fly ash brickwork in c.m (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat ofneat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size C.I grating etc all complete as per approved drawing, specification and direction of the Engineer in charge |
| 1236 | Gully trap chamber of size 250mmx250mm with R.C.C cover slab |
| 1237 | Supplying all materials, labour, T&P and constructing Inspection Chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6),moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
| 1238 | Inside size 760mm x 760mm x 460mm |
| 1239 | Fitting and fixing RCPC cover slab (0.45m dia) |
| 1240 | EXTERNAL PH WORK |
| 1241 | 1 Nos-Sinking of 200 mm dia (8\") Gravel Packed Production Well including saline sealing where necessary through Rotary Drilling Rig 300 Mtrs with PVC/ GI Casing Pipes- 2 Nos. |
| 1242 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level in alluvial soil strata by Mud Rotary Rig drilling as required to suit the site condition as per the direction of Engineer-in-Charge including use of own rigs with its accessories, tools and plant and consumables etc for lowering of finished bore suitable for lowering of 200 mm dia GI/PVC pipes for housing, fitted with socket and with or without well screen as per the necessity for the soft, medium, hard and boulder formation (GI/PVC casing pipes if required by the contractor to prevent collapse of over burden portion) including lower and withdrawing of casing pipe after drilling 200 mm to 450 mm dia in over burden portion. |
| 1243 | 00 mtrs. to 100 Mtrs. |
| 1244 | Supply ofall labour & T&P for lowering the following size G.I./PVC pipes with or without slotted pipes as per the necessity from ground level and fitted and fixed up in perfectly vertical position, including cutting and threading pipe and slotted pipe and fixing all jointing materials etc. complete and keeping the top of the casing pipe threaded including plugging tube wells to prevent entry of foreign materials from above excluding cost of fittings & jointing materials. |
| 1245 | 00 mtrs. to 300 Mtrs. |
| 1246 | Cleaning and developing the production well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per the direction of Engineer-in-Charge. |
| 1247 | Supplying all labour, tools and plant and grouting with cement bentonite slurry for saline sealing in the bore around the 200mm dia P.V.C. Casing pipe etc all complete as per the direction of the Engineer-in-Charge. (Excluding the cost of Cement.) |
| 1248 | Supplying all labour,T&P and materials forpacking the bore with washed gravel (size P-6)around the pipes in good quality excluding cost of gravel etc complete as per the direction of the Engineer-in-Charge. |
| 1249 | Supplying all materials labour and T&P and grouting with cement slurry for sanitary sealing around the GI/PVC casing pipe up to 3 mtrs. Below ground level including cost of cement all complete as per the direction of Engineer-in-Charge |
| 1250 | Supplying all materials, labour, tools and plant and withdrawing casing pipe from the unsuccessful bore and depositing in the departmental store in good condition. |
| 1251 | Cost of 200 mm dia PVC Pipe |
| 1252 | Cost of cement |
| 1253 | Cost of sand 75m |
| 1254 | washed gravel |
| 1255 | Cutting slots in casing pipe |
| 1256 | Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing,commissioning,trial running,conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge. |
| 1257 | 3HP Three Phase 5 stage submersible pump set. |
| 1258 | DOL control panel |
| 1259 | 50mm S. S. Nipple, S. S. bolt & clips |
| 1260 | 50mm M. S. Clamp, Bend, Socket & 200mm M. S. well cap |
| 1261 | 2.50mm Sqm Submersible flat cable |
| 1262 | Steel rope with cover |
| 1263 | 20mm dia rigid U-PVC pipe |
| 1264 | 50mm dia HDPE pipe |
| 1265 | Labour charges for lowering, testing, commissioning & transportation to site etc. |
| 1266 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor PVC pipesof the following nominal bore and pipe fittings with clamps including making good the wall and testing as per specification and direction of the Engineer in charge |
| 1267 | 50mm dia PVCpipe (sch-80) |
| 1268 | Earth work in all kinds of soil within 50 mtr initial lead and 1.5mtr initial lift includingrough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3 mtr in depth and as per direction of the Engineer in charge. |
| 1269 | 25m x 0.45m x 0.60m |
| 1270 | Supplying all materials, labour T&P and fitting and fixing brass/CP/PVC fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer in charge. |
| 1271 | 40mm dia Brass N. R. Valve |
| 1272 | 40mm dia Brass F. W. Valve |
| 1273 | Supplying all materials, labour, T&P and construction of Fullway valve chamber/Stop cock chamber of the following inside size for fullway valve with cement concrete slab (1:2:4) mix , 7.50cm thick, foundation concrete (1:5:10) and inside plastering with cement mortar (1:3) finished with a floating coat of neat cement including curing etc all complete as per approved specification and direction of the Engineer in charge |
| 1274 | Inside size 250mm x 250mm x 560mm |
| 1275 | Supplying all materials, labour, T&P and constructionman hole chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1½:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
| 1276 | Inside size 910mm x 910mm x 910mm |
| 1277 | Addl depth |
| 1278 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class K.B brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
| 1279 | 1.22m dia x 2.10m deep soakway pit |
| 1280 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasingincluding concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. |
| 1281 | 110mm dia u-pvc pipe alround concrete |
| 1282 | 160mm dia u-pvc pipe alround concrete |
| 1283 | Construction of 6000 Liters RCCUGR WITH PUMPING ARRAGEMENTof Inside size- 3.50 X 2.50 X1.80m |
| 1284 | Earth work in All kinds of soil and gravels mixed with stone and boulder not exceeding 0.014 Cum in volume within 50m initiallead and 1.5 m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per specification approved by the Department. |
| 1285 | UGR - 1x2.950x2.65x1.50 |
| 1286 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer incharge. |
| 1287 | UGR -1x2.950x2.65x0.15 |
| 1288 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1289 | UGR -1x2.950x2.65x0.15 |
| 1290 | Supplying all materials, labour,T&P and providing cement concrete M25 for RCC work using 12mm HG chips including hoisting,laying,curring and conveyance of all materials to site etc complete. |
| 1291 | Base slab 1x2.95x2.65x0.15 |
| 1292 | Long wall - 2x2.70x0.15x1.50 |
| 1293 | Short wall- 2x2.10x0.15x1.50 |
| 1294 | Roof Slab - 1x2.70x2.40x0.15 |
| 1295 | Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage. |
| 1296 | @ 100 kg / cum = |
| 1297 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor. |
| 1298 | RCC floor roof, chajja etc |
| 1299 | Roof Slab- 1x2.40x2.10 |
| 1300 | In Sides - 2x(2.4+2.10)x1.50 |
| 1301 | OutSides - 2x(2.7+2.40)x1.50 |
| 1302 | Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) overCC workincluding watering curring and conveyance of all materialsto site. |
| 1303 | Bottom - 1x2.40x2.10 |
| 1304 | Wall inside - 2x(2.4+2.10)x1.50 |
| 1305 | Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site. |
| 1306 | Quantity same as item No-4 |
| 1307 | Providing fitting and fixing CI/MS step iron including fixing to walletc. complete |
| 1308 | Providing fitting and fixing RCPCcoveretc complete as per direction of Engineer-in-charge |
| 1309 | Supply all materials, labour, T&P and providing, fitting and fixing of centrifugal pump set to run on 3phase/1phase line voltage ranging from 320 volt to 450 volt with suitable control pannel, jointing with GI/ PVC/ HDPE pipes electrification, testing,commissioning,trial running,conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge. |
| 1310 | 3HP 3 phase Monoblock Centrifugal pump set. |
| 1311 | DOL control panel |
| 1312 | Labour charges for lowering, testing, commissioning & transportation to site etc. |
| 1313 | 2.50mm Sqm Submersible flat cable |
| 1314 | Steel rope with cover |
| 1315 | 20mm dia rigid U-PVC pipe |
| 1316 | 50mm dia HDPE pipe |
| 1317 | Construction of 30 users septic tank |
| 1318 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of theEngineer-in-Charge. |
| 1319 | 4.09mx2.09mx1.50m= |
| 1320 | Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. |
| 1321 | 4.09mx2.09mx0.63m= |
| 1322 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1323 | In ground floor |
| 1324 | 4.09mx2.09mx0.08m= |
| 1325 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12m size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1326 | In ground floor |
| 1327 | 4.09mx2.09mx0.15m= |
| 1328 | 3.13mx1.13mx½(0.03m+0.13m)= |
| 1329 | Supplying all materials, labour, T&P and providing brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1330 | In F&P |
| 1331 | 2(3.89m+1.13m)0.38mx0.70m= |
| 1332 | 2(3.63m+1.13m)0.25mx1.30m= |
| 1333 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1334 | In ground floor |
| 1335 | Inside |
| 1336 | (1.92m+1.87m)1.13m= |
| 1337 | 2x3.13mx1.90m= |
| 1338 | Outside |
| 1339 | 2(3.89m+1.89m)0.70m= |
| 1340 | 2(3.63m+1.63)1.43m= |
| 1341 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1342 | In ground floor |
| 1343 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1344 | R.C.C floor androofslabs |
| 1345 | In ground floor |
| 1346 | 3.10mx1.10m= |
| 1347 | 2(3.66m+1.66m)0.10m= |
| 1348 | Supplying all materials, labour, T&P and providing M.Sreinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1349 | In ground floor |
| 1350 | Supplying all materials, labour, T&P and providing cement concrete (M25) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1351 | In ground floor |
| 1352 | 3.66mx1.66mx0.10m= |
| 1353 | Supplying all materials, labour, T&P and providing,fitting and fixing 100mm x 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification anddirection of the Engineer in charge |
| 1354 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls ofman hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 1355 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 1356 | 2(4.09m+1.89m)0.10mx0.70m= |
| 1357 | 2(4.09m+1.63m)x0.23mx1.20m= |
| 1358 | ACADEMIC BLOCK |
| 1359 | A- Internal PH Work |
| 1360 | Supplying all materials, labour,T&Pand providing and fixing to wall or ceiling and floor ChlorinatedPolyvinyl Chloride (C-PVC) pipes (Make-Astral/Supreme/Finolex) conforming to IS:15778,having thermal stability for hot & cold water supply , including all CPVCplain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes &fittings with one step CPVCsolvent cement and testing of joints complete as per direction of Engineer -in-Charge. |
| 1361 | GroundFloor |
| 1362 | 20mm dia C-PVC pipe |
| 1363 | 25mm dia C-PVC pipe |
| 1364 | 32mm dia C-PVC pipe |
| 1365 | 40mm dia C-PVC pipe |
| 1366 | In 1st Floor |
| 1367 | 20mm dia C-PVC pipe |
| 1368 | 25mm dia C-PVC pipe |
| 1369 | 32mm dia C-PVC pipe |
| 1370 | 40mm dia C-PVC pipe |
| 1371 | In 2nd Floor |
| 1372 | 25mm dia C-PVC pipe |
| 1373 | 32mm dia C-PVC pipe |
| 1374 | 40mm dia C-PVC pipe |
| 1375 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge. |
| 1376 | 250mmthick wall in Ground floor |
| 1377 | In 1st Floor |
| 1378 | In 2nd Floor |
| 1379 | Supplying all materials, labour, T&Pand cutting hole in R.C.C floors, roofs, etc upto 19 cm thickfor passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes afterinsertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of theEngineer in charge.in Ground Floor |
| 1380 | In 1st Floor |
| 1381 | Supplying allmaterials, labour, T&P and cutting grooves in pucca floors and walls for takingGI/ PVC pipes and making good the damages as per the direction of the Engineer in charge. In Ground Floor |
| 1382 | In 1st Floor |
| 1383 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all completeas per PH specification and direction of the Engineer in charge |
| 1384 | 250mm to 375mmthick wall |
| 1385 | in 1st Floor to 5th Floor |
| 1386 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge |
| 1387 | 15mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make) |
| 1388 | 15mm dia CP CP Angle stop cock (Jaquar-Con-CHR-053KN) |
| 1389 | 15mm dia CP extension piece |
| 1390 | 15mm dia CP Pillar cock (Jaquar-Con-CHR-011KN) |
| 1391 | 25mm dia G.M or Brass F.W valve (Sakti make) |
| 1392 | 32mm dia G.M or Brass F.W valve (Sakti make) |
| 1393 | 40mm dia G.M or Brass F.W valve (Sakti make) |
| 1394 | 125mm dia CP gratings |
| 1395 | Supplying all materials, labour, T&P and fitting and fixing 12.50 litres/10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge |
| 1396 | 10 litres PVC L.L. Cistern (Slimline-white) |
| 1397 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering,watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge |
| 1398 | 2000 Ltr PVC water storage tank (3 Layer White)-on 2nd. Floor |
| 1399 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS UV/80 SS UV of size 750x570x1350mm height with water storage capacity 120 liters along with 3 nos of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all completeas per approved drawing,specification and direction of the Engineer in charge. |
| 1400 | Aquaguard cooler cum purifier(Aqualguard pure chill 80 SS UV) |
| 1401 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings (Make-Supreme/Finolex) of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricantby non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge. |
| 1402 | 75mm dia U-PVC SWR pipes |
| 1403 | 75mm U-PVC plain bend |
| 1404 | 110mm dia U-PVC SWR pipes |
| 1405 | 110mm U-PVC door bend |
| 1406 | 110mm U-PVC door Tee |
| 1407 | 110mm U-PVC plain Tee |
| 1408 | 110mm dia U-PVC offset without ear |
| 1409 | 110mm U-PVC plain bend |
| 1410 | 110mm U-PVC vent cowl |
| 1411 | 110mm dia U-PVC \"P\" trap |
| 1412 | 110mm dia U-PVC socket plain |
| 1413 | 75mm dia U-PVC socket plain |
| 1414 | PVC Clamp |
| 1415 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan conforming to IS:2556-part-3-2004) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x 30mm footrest, fixing 100mm dia HCI ‘P’ or ‘S’ trap (with/without 50mm dia horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc all complete as per specification and direction of the Engineer in charge(Nycer,parryware make) |
| 1416 | 580mm size Orissa pan(Hindware/Parryware/Neycer) |
| 1417 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make),etc all complete as per specification and direction of the Engineer in charge |
| 1418 | Under counter basin(Hindware)No.10095+ALD-CHR-709+ALD-CHR-803AB+KUB-35001F |
| 1419 | Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge |
| 1420 | 600mm x 450mm size B.E mirror |
| 1421 | Mirror of best quality of 2100mmx600mm |
| 1422 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 1423 | 600 x 125mm plate glass shelf with CP guard rails( Jaquar -AKP-3577P) |
| 1424 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 1425 | 25mm x 600mm long CP towel rail (Jaquar -ACN-111SM) |
| 1426 | CP towel Ring(Jaquar -ACN-1121N) |
| 1427 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 1428 | CP soap holder( Jaquar -ACN-1131N) |
| 1429 | Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink with outlet at end and weir overflow including fitting and fixing a pair of cast iron or MS brackets painted white, fixing 50mm/40mm dia CP brass waste, fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge |
| 1430 | 600 x 450 x 250mm size Porcelain sink (Parryware/Hindware/Cera or Equevalent make) |
| 1431 | Supplying all materials labour T&P and filling in foundation and plinth with sandwellwatered and rammed including conveyance of all materials to work sitepayment of royalty taxes etc all complete as per direction ofEngineer in charge In ground floor |
| 1432 | L Toilet1x5.97x4.06x0.30= |
| 1433 | G. Toilet1x5.97x3.48x0.30= |
| 1434 | PWD. Toilet1x3.23x2.40x0.30= |
| 1435 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
| 1436 | L Toilet1x5.97x4.06x0.10= |
| 1437 | G. Toilet1x5.97x3.48x0.10= |
| 1438 | PWD. Toilet1x3.23x2.40x0.10= |
| 1439 | Supply of all materials & laying the waterproofing material of Dr.Fixit torch shield P3160(3mm)with its primer 2 coats or equivalent water proofing material after drying cleaning the concrete surface over the concrete floor/roof/ balcony/sunken and dado upto 1\"6\" in wall including cleaning,applying and mending as per specification including cost,conveyance,taxes,royalities of all materials to work site etc.all complete as per the direction of the Engineer-in-charge.(Sqm) |
| 1440 | In Ist Floor (sunkeen floor) |
| 1441 | L Toilet1x5.97x4.06 |
| 1442 | G. Toilet1x5.97x3.48 |
| 1443 | PWD. Toilet1x3.23x2.40 |
| 1444 | (sunkeen Wall) |
| 1445 | L\" Toilet 1x2x(5.97+4.06)x0.45 |
| 1446 | G\" Toilet 1x2x(5.97+3.48)x0.45 |
| 1447 | PWDToilet 1x2x(2.40+3.23)x0.45 |
| 1448 | Supplying all materials, labour, T&P and providing and filling cynder including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1449 | In FirstFloor floor |
| 1450 | L Toilet1x3.75x2.50x0.15= |
| 1451 | G. Toilet1x5.20x2.66x0.15= |
| 1452 | PWD. Toilet1x2.40x2.66x0.15= |
| 1453 | Supplying all materials, labour, T&P and constructing Gully Trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, Fly ash brickwork in c.m (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat ofneat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size C.I grating etc all complete as per approved drawing, specification and direction of the Engineer in charge |
| 1454 | Gully trap chamber of size 250mmx250mm with R.C.C cover slab |
| 1455 | Supplying all materials, labour, T&P and constructing Inspection Chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6),moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
| 1456 | Inside size 760mm x 760mm x 460mm |
| 1457 | Fitting and fixing RCPC cover slab (0.45m dia) |
| 1458 | EXTERNAL PH WORK |
| 1459 | 1 Nos-Sinking of 200 mm dia (8\") Gravel Packed Production Well including saline sealing where necessary through Rotary Drilling Rig 300 Mtrs with PVC/ GI Casing Pipes- 2 Nos. |
| 1460 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level in alluvial soil strata by Mud Rotary Rig drilling as required to suit the site condition as per the direction of Engineer-in-Charge including use of own rigs with its accessories, tools and plant and consumables etc for lowering of finished bore suitable for lowering of 200 mm dia GI/PVC pipes for housing, fitted with socket and with or without well screen as per the necessity for the soft, medium, hard and boulder formation (GI/PVC casing pipes if required by the contractor to prevent collapse of over burden portion) including lower and withdrawing of casing pipe after drilling 200 mm to 450 mm dia in over burden portion. |
| 1461 | 00 mtrs. to 100 Mtrs. |
| 1462 | Supply ofall labour & T&P for lowering the following size G.I./PVC pipes with or without slotted pipes as per the necessity from ground level and fitted and fixed up in perfectly vertical position, including cutting and threading pipe and slotted pipe and fixing all jointing materials etc. complete and keeping the top of the casing pipe threaded including plugging tube wells to prevent entry of foreign materials from above excluding cost of fittings & jointing materials. |
| 1463 | 00 mtrs. to 300 Mtrs. |
| 1464 | Cleaning and developing the production well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per the direction of Engineer-in-Charge. |
| 1465 | Supplying all labour, tools and plant and grouting with cement bentonite slurry for saline sealing in the bore around the 200mm dia P.V.C. Casing pipe etc all complete as per the direction of the Engineer-in-Charge. (Excluding the cost of Cement.) |
| 1466 | Supplying all labour,T&P and materials forpacking the bore with washed gravel (size P-6)around the pipes in good quality excluding cost of gravel etc complete as per the direction of the Engineer-in-Charge. |
| 1467 | Supplying all materials labour and T&P and grouting with cement slurry for sanitary sealing around the GI/PVC casing pipe up to 3 mtrs. Below ground level including cost of cement all complete as per the direction of Engineer-in-Charge |
| 1468 | Supplying all materials, labour, tools and plant and withdrawing casing pipe from the unsuccessful bore and depositing in the departmental store in good condition. |
| 1469 | Cost of 200 mm dia PVC Pipe |
| 1470 | Cost of cement |
| 1471 | Cost of sand 75m |
| 1472 | washed gravel |
| 1473 | Cutting slots in casing pipe |
| 1474 | Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing,commissioning,trial running,conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge. |
| 1475 | 3HP Three Phase 5 stage submersible pump set. |
| 1476 | DOL control panel |
| 1477 | 50mm S. S. Nipple, S. S. bolt & clips |
| 1478 | 50mm M. S. Clamp, Bend, Socket & 200mm M. S. well cap |
| 1479 | 2.50mm Sqm Submersible flat cable |
| 1480 | Steel rope with cover |
| 1481 | 20mm dia rigid U-PVC pipe |
| 1482 | 50mm dia HDPE pipe |
| 1483 | Labour charges for lowering, testing, commissioning & transportation to site etc. |
| 1484 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor PVC pipesof the following nominal bore and pipe fittings with clamps including making good the wall and testing as per specification and direction of the Engineer in charge |
| 1485 | 50mm dia PVCpipe (sch-80) |
| 1486 | Earth work in all kinds of soil within 50 mtr initial lead and 1.5mtr initial lift includingrough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3 mtr in depth and as per direction of the Engineer in charge. |
| 1487 | 100m x 0.45m x 0.60m |
| 1488 | Supplying all materials, labour T&P and fitting and fixing brass/CP/PVC fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer in charge. |
| 1489 | 40mm dia Brass N. R. Valve |
| 1490 | 40mm dia Brass F. W. Valve |
| 1491 | Supplying all materials, labour, T&P and construction of Fullway valve chamber/Stop cock chamber of the following inside size for fullway valve with cement concrete slab (1:2:4) mix , 7.50cm thick, foundation concrete (1:5:10) and inside plastering with cement mortar (1:3) finished with a floating coat of neat cement including curing etc all complete as per approved specification and direction of the Engineer in charge |
| 1492 | Inside size 250mm x 250mm x 560mm |
| 1493 | Supplying all materials, labour, T&P and constructionman hole chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1½:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
| 1494 | Inside size 910mm x 910mm x 910mm |
| 1495 | Addl depth |
| 1496 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class K.B brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
| 1497 | 1.22m dia x 2.10m deep soakway pit |
| 1498 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasingincluding concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. |
| 1499 | 110mm dia u-pvc pipe alround concrete |
| 1500 | 160mm dia u-pvc pipe alround concrete |
| 1501 | Construction of Pump House (size 3.5x2.50x3.0) over U G R |
| 1502 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12m size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1503 | In G.Floor, |
| 1504 | Room floor |
| 1505 | 3.5x2.5x0.05 |
| 1506 | Supplying all materials, labour, T&P and providing brick work with Fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1507 | In Superstructure |
| 1508 | Long wall(a)2x3.50x0.25x2.70 |
| 1509 | Shortwall(a)2x2.50x0.25x2.70 |
| 1510 | Deduction for |
| 1511 | Door1x0.90x2.10x0x25 |
| 1512 | windows2x0.90x1.20x0.25 |
| 1513 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1514 | In G.floorPump house |
| 1515 | wall inside 1x2(3.50+2.50)x3.0 |
| 1516 | Ceiling3.5x2.5 |
| 1517 | wall outside1x2(4.0+3.0)x3.50 |
| 1518 | Roof slab Top1x4.25x3.25 |
| 1519 | Roof slab Sides 1x2x(4.25+3.25)x0.25 |
| 1520 | Supplying all materials, labour, T&P and providing cement concrete M25 with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1521 | In G.floor |
| 1522 | Column 4x0.25x0.25x3.0 |
| 1523 | Lintel Beam2x4.0x0.25x0.15 |
| 1524 | 2x2.5x0.25x0.15 |
| 1525 | RoofBeam2x4.0x0.25x0.25 |
| 1526 | 2x2.5x0.25x0.25 |
| 1527 | Door Chajja1x1.20x0.80x0.06 |
| 1528 | Window Chajja2x1.20x0.80x0.06 |
| 1529 | Roof slab 1x4.25x3.25x00.125 |
| 1530 | Supplying all materials, labour, T&P and providing M.Sreinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1531 | In ground floor |
| 1532 | Column 4x0.25x0.25x3.0 |
| 1533 | Lintel Beam2x4.0x0.25x0.15 |
| 1534 | 2x2.5x0.25x0.15 |
| 1535 | RoofBeam 2x4.0x0.25x0.25 |
| 1536 | 2x2.5x0.25x0.25 |
| 1537 | Door Chajja1x1.20x0.80x0.06 |
| 1538 | Window Chajja2x1.20x0.80x0.06 |
| 1539 | Roof slab 1x4.25x3.25x00.125 |
| 1540 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1541 | R.C.C Column and beam |
| 1542 | In ground floor |
| 1543 | Column 4x4x0.25x3.0 |
| 1544 | Lintel Beam |
| 1545 | out side2x(4.0+3.0)x0.15 |
| 1546 | Inside 2x(3.50+2.50)x0.15 |
| 1547 | RoofBeam |
| 1548 | out side 2x(4.0+3.0)x0.25 |
| 1549 | Inside 2x(3.50+2.50)x0.25 |
| 1550 | R.C.CFloor and roof slab |
| 1551 | Door Chajja 1x1.20x0.80 |
| 1552 | 1x(1.2+0.8+0.8)x0.06 |
| 1553 | Window Chajja2x1.20x0.80 |
| 1554 | ceiling2x(1.20+0.80+0.80)x0.06 |
| 1555 | Roof slab |
| 1556 | Ceiing3.50x2.50 |
| 1557 | Sides 1x2x(4.0+3.0)x0.25 |
| 1558 | Construction of 50 users RCC septic tank- 1 No. |
| 1559 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of theEngineer-in-Charge. |
| 1560 | 1x6.80x2.74x1.50=27.95 |
| 1561 | Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. |
| 1562 | 1x6.80x2.74x0.30=5.59 |
| 1563 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer incharge. |
| 1564 | 1x6.50x2.37x0.20=3.08 |
| 1565 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1566 | In ground floor |
| 1567 | 1x6.50x2.37x0.20=3.08 |
| 1568 | Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1569 | In ground floor (inside/outside) |
| 1570 | I/S-1x(5.00+1.60)x2.40=15.84 |
| 1571 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1572 | In ground floor (inside/outside) |
| 1573 | I/S-1x(5.00+1.60)x2.40=15.84 |
| 1574 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1575 | R.C.C floor and roof slabs up to 4.30m height |
| 1576 | I/S-1x5.00x1.60=8.00 |
| 1577 | Buffle wall-1x2x1.60x0.732=2.34 |
| 1578 | R.C.C walletc. |
| 1579 | I/S-1x2x(5.00+1.60)x2.40=31.68 |
| 1580 | O/S-1x2(5.80+2.40)x2.55=41.82 |
| 1581 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1582 | In ground floor |
| 1583 | Supplying all materials, labour, T&P and providing cement concrete M25with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1584 | In ground floor |
| 1585 | Base-1x5.80x2.40x0.125=1.74 |
| 1586 | Slab-1x5.50x2.10x0.13=1.50 |
| 1587 | Wall-1x14.20x0.25x2.40=8.52 |
| 1588 | Construction of 20000 Liters RCC Under ground Reserverof Inside size- 4.00 X 3.00 X2.00m |
| 1589 | Earth work in All kinds of soil and gravels mixed with stone and boulder not exceeding 0.014 Cum in volume within 50m initiallead and 1.5 m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per specification approved by the Department. |
| 1590 | UGR - 1x5.90x4.90x1.50 |
| 1591 | -do- with Ist additional depth of 1.50 m over the initial lead and lift |
| 1592 | UGR - 1x5.90x4.90x0.70 |
| 1593 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer incharge. |
| 1594 | UGR - 1x5.90x4.90x0.20 |
| 1595 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1596 | UGR - 1x4.70x3.70x0.10 |
| 1597 | Supplying all materials, labour,T&P and providing cement concrete M25for RCC work using 12mm HG chips including hoisting,laying,curring and conveyance of all materials to site etc complete. |
| 1598 | Base slab 1x4.70x3.70x0.20 |
| 1599 | Long wall - 2x4.40x0.20x2.0 |
| 1600 | Short wall- 2x3.00x0.20x2.0 |
| 1601 | Roof Slab - 1x4.40x3.40x0.15 |
| 1602 | Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage. |
| 1603 | @ 100 kg / cum = |
| 1604 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor. |
| 1605 | RCC floor roof, chajja etc |
| 1606 | Roof Slab- 1x4.0x3.0 |
| 1607 | Sides - 2x(4.40+3.40)x0.15 |
| 1608 | RCC wall & Fins etc |
| 1609 | Long wallinside - 2x4.00x2.0 |
| 1610 | Long wallout side - 2x4.40x2.0 |
| 1611 | Short wall inside- 2x3.0x2.0 |
| 1612 | Short wall out side- 2x3.40x2.0 |
| 1613 | RCC Plinth bend/ Raft |
| 1614 | Base slab2(4.7+3.7)x0.50 |
| 1615 | Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) overCC workincluding watering curring and conveyance of all materialsto site. |
| 1616 | Bottom - 1x4.0x3.0 |
| 1617 | Wall- 2(4.0+3.0)x2.00 |
| 1618 | Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site. |
| 1619 | Quantity same as item No-4 |
| 1620 | Providing fitting and fixing CI/MS step iron including fixing to walletc. complete |
| 1621 | Providing fitting and fixing RCPCcoveretc complete as per direction of Engineer-in-charge |
| 1622 | Supply all materials, labour, T&P and providing, fitting and fixing of centrifugal pump set to run on 3phase/1phase line voltage ranging from 320 volt to 450 volt with suitable control pannel, jointing with GI/ PVC/ HDPE pipes electrification, testing,commissioning,trial running,conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge. |
| 1623 | 3HP 3 phase Monoblock Centrifugal pump set. |
| 1624 | DOL control panel |
| 1625 | Labour charges for lowering, testing, commissioning & transportation to site etc. |
| 1626 | GIRLS HOSTEL |
| 1627 | A- Internal PH Work |
| 1628 | Supplying all materials, labour,T&Pand providing and fixing to wall or ceiling and floor ChlorinatedPolyvinyl Chloride (C-PVC) pipes (Make-Astral/Supreme/Finolex) conforming to IS:15778,having thermal stability for hot & cold water supply , including all CPVCplain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes &fittings with one step CPVCsolvent cement and testing of joints complete as per direction of Engineer -in-Charge. |
| 1629 | GroundFloor |
| 1630 | 20mm dia C-PVC pipe |
| 1631 | 25mm dia C-PVC pipe |
| 1632 | 32mm dia C-PVC pipe |
| 1633 | 40mm dia C-PVC pipe |
| 1634 | In 1st Floor |
| 1635 | 20mm dia C-PVC pipe |
| 1636 | 25mm dia C-PVC pipe |
| 1637 | 32mm dia C-PVC pipe |
| 1638 | 40mm dia C-PVC pipe |
| 1639 | In 2nd Floor |
| 1640 | 25mm dia C-PVC pipe |
| 1641 | 32mm dia C-PVC pipe |
| 1642 | 40mm dia C-PVC pipe |
| 1643 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge. |
| 1644 | 250mmthick wall in Ground floor |
| 1645 | In 1st Floor |
| 1646 | In 2nd Floor |
| 1647 | Supplying all materials, labour, T&Pand cutting hole in R.C.C floors, roofs, etc upto 19 cm thickfor passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes afterinsertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of theEngineer in charge.in Ground Floor |
| 1648 | In 1st Floor |
| 1649 | Supplying allmaterials, labour, T&P and cutting grooves in pucca floors and walls for takingGI/ PVC pipes and making good the damages as per the direction of the Engineer in charge. In Ground Floor |
| 1650 | In 1st Floor |
| 1651 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all completeas per PH specification and direction of the Engineer in charge |
| 1652 | 250mm to 375mmthick wall |
| 1653 | in 1st Floor to 5th Floor |
| 1654 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge |
| 1655 | 15mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make) |
| 1656 | 15mm dia CP CP Angle stop cock (Jaquar-Con-CHR-053KN) |
| 1657 | 15mm dia CP extension piece |
| 1658 | 15mm dia CP Pillar cock (Jaquar-Con-CHR-011KN) |
| 1659 | 25mm dia G.M or Brass F.W valve (Sakti make) |
| 1660 | 32mm dia G.M or Brass F.W valve (Sakti make) |
| 1661 | 40mm dia G.M or Brass F.W valve (Sakti make) |
| 1662 | 125mm dia CP gratings |
| 1663 | Supplying all materials, labour, T&P and fitting and fixing 12.50 litres/10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge |
| 1664 | 10 litres PVC L.L. Cistern (Slimline-white) |
| 1665 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering,watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge |
| 1666 | 2000 Ltr PVC water storage tank (3 Layer White)-on 2nd. Floor |
| 1667 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS UV/80 SS UV of size 750x570x1350mm height with water storage capacity 120 liters along with 3 nos of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all completeas per approved drawing,specification and direction of the Engineer in charge. |
| 1668 | Aquaguard cooler cum purifier(Aqualguard pure chill 80 SS UV) |
| 1669 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings (Make-Supreme/Finolex) of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricantby non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge. |
| 1670 | 75mm dia U-PVC SWR pipes |
| 1671 | 75mm U-PVC plain bend |
| 1672 | 110mm dia U-PVC SWR pipes |
| 1673 | 110mm U-PVC door bend |
| 1674 | 110mm U-PVC door Tee |
| 1675 | 110mm U-PVC plain Tee |
| 1676 | 110mm dia U-PVC offset without ear |
| 1677 | 110mm U-PVC plain bend |
| 1678 | 110mm U-PVC vent cowl |
| 1679 | 110mm dia U-PVC \"P\" trap |
| 1680 | 110mm dia U-PVC socket plain |
| 1681 | 75mm dia U-PVC socket plain |
| 1682 | PVC Clamp |
| 1683 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan conforming to IS:2556-part-3-2004) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x 30mm footrest, fixing 100mm dia HCI ‘P’ or ‘S’ trap (with/without 50mm dia horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc all complete as per specification and direction of the Engineer in charge(Nycer,parryware make) |
| 1684 | 580mm size Orissa pan(Hindware/Parryware/Neycer) |
| 1685 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make),etc all complete as per specification and direction of the Engineer in charge |
| 1686 | Under counter basin(Hindware)No.10095+ALD-CHR-709+ALD-CHR-803AB+KUB-35001F |
| 1687 | 550mm x 400mm size W. H. Basin with Porcelain Pedestal (Parryware/Hindware/Neycer) |
| 1688 | Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge |
| 1689 | 600mm x 450mm size B.E mirror |
| 1690 | Mirror of best quality of 2100mmx600mm |
| 1691 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 1692 | 600 x 125mm plate glass shelf with CP guard rails( Jaquar -AKP-3577P) |
| 1693 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 1694 | 25mm x 600mm long CP towel rail (Jaquar -ACN-111SM) |
| 1695 | CP towel Ring(Jaquar -ACN-1121N) |
| 1696 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 1697 | CP soap holder( Jaquar -ACN-1131N) |
| 1698 | Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink with outlet at end and weir overflow including fitting and fixing a pair of cast iron or MS brackets painted white, fixing 50mm/40mm dia CP brass waste, fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge |
| 1699 | 600 x 450 x 250mm size kitchen S Ssink (Jayana/Niralior Equevalent make) |
| 1700 | Supplying all materials labour T&P and filling in foundation and plinth with sandwellwatered and rammed including conveyance of all materials to work sitepayment of royalty taxes etc all complete as per direction ofEngineer in charge In ground floor |
| 1701 | Toilet1x6.65x3.75x0.30= |
| 1702 | KitchenToilet1x2.43x1.45x0.30= |
| 1703 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
| 1704 | Toilet1x6.65x3.65x0.30= |
| 1705 | KitchenToilet1x2.43x1.45x0.30= |
| 1706 | Supply of all materials & laying the waterproofing material of Dr.Fixit torch shield P3160(3mm)with its primer 2 coats or equivalent water proofing material after drying cleaning the concrete surface over the concrete floor/roof/ balcony/sunken and dado upto 1\"6\" in wall including cleaning,applying and mending as per specification including cost,conveyance,taxes,royalities of all materials to work site etc.all complete as per the direction of the Engineer-in-charge.(Sqm) |
| 1707 | In Ist Floor (sunkeen floor) |
| 1708 | Toilet1x6.65x3.75x0.30= |
| 1709 | (sunkeen Wall) |
| 1710 | Toilet 1x2x(6.65+3.75)x0.45 |
| 1711 | Supplying all materials, labour, T&P and providing and filling cynder including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1712 | In FirstFloor floor |
| 1713 | Toilet1x6.65x3.75x0.20= |
| 1714 | Supplying all materials, labour, T&P and constructing Gully Trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, Fly ash brickwork in c.m (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat ofneat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size C.I grating etc all complete as per approved drawing, specification and direction of the Engineer in charge |
| 1715 | Gully trap chamber of size 250mmx250mm with R.C.C cover slab |
| 1716 | Supplying all materials, labour, T&P and constructing Inspection Chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6),moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
| 1717 | Inside size 760mm x 760mm x 460mm |
| 1718 | Fitting and fixing RCPC cover slab (0.45m dia) |
| 1719 | EXTERNAL PH WORK |
| 1720 | 1 No-Sinking of 200 mm dia (8\") Gravel Packed Production Well including saline sealing where necessary through Rotary Drilling Rig 300 Mtrs with PVC/ GI Casing Pipes- 2 Nos. |
| 1721 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level in alluvial soil strata by Mud Rotary Rig drilling as required to suit the site condition as per the direction of Engineer-in-Charge including use of own rigs with its accessories, tools and plant and consumables etc for lowering of finished bore suitable for lowering of 200 mm dia GI/PVC pipes for housing, fitted with socket and with or without well screen as per the necessity for the soft, medium, hard and boulder formation (GI/PVC casing pipes if required by the contractor to prevent collapse of over burden portion) including lower and withdrawing of casing pipe after drilling 200 mm to 450 mm dia in over burden portion. |
| 1722 | 00 mtrs. to 100 Mtrs. |
| 1723 | Supply ofall labour & T&P for lowering the following size G.I./PVC pipes with or without slotted pipes as per the necessity from ground level and fitted and fixed up in perfectly vertical position, including cutting and threading pipe and slotted pipe and fixing all jointing materials etc. complete and keeping the top of the casing pipe threaded including plugging tube wells to prevent entry of foreign materials from above excluding cost of fittings & jointing materials. |
| 1724 | 00 mtrs. to 300 Mtrs. |
| 1725 | Cleaning and developing the production well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per the direction of Engineer-in-Charge. |
| 1726 | Supplying all labour, tools and plant and grouting with cement bentonite slurry for saline sealing in the bore around the 200mm dia P.V.C. Casing pipe etc all complete as per the direction of the Engineer-in-Charge. (Excluding the cost of Cement.) |
| 1727 | Supplying all labour,T&P and materials forpacking the bore with washed gravel (size P-6)around the pipes in good quality excluding cost of gravel etc complete as per the direction of the Engineer-in-Charge. |
| 1728 | Supplying all materials labour and T&P and grouting with cement slurry for sanitary sealing around the GI/PVC casing pipe up to 3 mtrs. Below ground level including cost of cement all complete as per the direction of Engineer-in-Charge |
| 1729 | Supplying all materials, labour, tools and plant and withdrawing casing pipe from the unsuccessful bore and depositing in the departmental store in good condition. |
| 1730 | Cost of 200 mm dia PVC Pipe |
| 1731 | Cost of cement |
| 1732 | Cost of sand 75m |
| 1733 | washed gravel |
| 1734 | Cutting slots in casing pipe |
| 1735 | Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing,commissioning,trial running,conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge. |
| 1736 | 3HP Three Phase 5 stage submersible pump set. |
| 1737 | 3HP Three Phase mono block centrifugal submersible pump set. |
| 1738 | DOL control panel |
| 1739 | 50mm S. S. Nipple, S. S. bolt & clips |
| 1740 | 50mm M. S. Clamp, Bend, Socket & 200mm M. S. well cap |
| 1741 | 2.50mm Sqm Submersible flat cable |
| 1742 | Steel rope with cover |
| 1743 | 20mm dia rigid U-PVC pipe |
| 1744 | 50mm dia HDPE pipe |
| 1745 | Labour charges for lowering, testing, commissioning & transportation to site etc. |
| 1746 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor PVC pipesof the following nominal bore and pipe fittings with clamps including making good the wall and testing as per specification and direction of the Engineer in charge |
| 1747 | 50mm dia PVCpipe (sch-80) |
| 1748 | Earth work in all kinds of soil within 50 mtr initial lead and 1.5mtr initial lift includingrough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3 mtr in depth and as per direction of the Engineer in charge. |
| 1749 | 50m x 0.45m x 0.60m |
| 1750 | Supplying all materials, labour T&P and fitting and fixing brass/CP/PVC fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer in charge. |
| 1751 | 40mm dia Brass N. R. Valve |
| 1752 | 40mm dia Brass F. W. Valve |
| 1753 | Supplying all materials, labour, T&P and construction of Fullway valve chamber/Stop cock chamber of the following inside size for fullway valve with cement concrete slab (1:2:4) mix , 7.50cm thick, foundation concrete (1:5:10) and inside plastering with cement mortar (1:3) finished with a floating coat of neat cement including curing etc all complete as per approved specification and direction of the Engineer in charge |
| 1754 | Inside size 250mm x 250mm x 560mm |
| 1755 | Supplying all materials, labour, T&P and constructionman hole chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1½:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
| 1756 | Inside size 910mm x 910mm x 910mm |
| 1757 | Addl depth |
| 1758 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class K.B brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
| 1759 | 1.22m dia x 2.10m deep soakway pit |
| 1760 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasingincluding concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. |
| 1761 | 110mm dia u-pvc pipe alround concrete |
| 1762 | 160mm dia u-pvc pipe alround concrete |
| 1763 | Construction of 50 users RCC septic tank- 1 No. |
| 1764 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of theEngineer-in-Charge. |
| 1765 | 1x6.80x2.74x1.50=27.95 |
| 1766 | Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. |
| 1767 | 1x6.80x2.74x0.30=5.59 |
| 1768 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer incharge. |
| 1769 | 1x6.50x2.37x0.20=3.08 |
| 1770 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1771 | In ground floor |
| 1772 | 1x6.50x2.37x0.20=3.08 |
| 1773 | Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1774 | In ground floor (inside/outside) |
| 1775 | I/S-1x(5.00+1.60)x2.40=15.84 |
| 1776 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1777 | In ground floor (inside/outside) |
| 1778 | I/S-1x(5.00+1.60)x2.40=15.84 |
| 1779 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1780 | R.C.C floor and roof slabs up to 4.30m height |
| 1781 | I/S-1x5.00x1.60=8.00 |
| 1782 | Buffle wall-1x2x1.60x0.732=2.34 |
| 1783 | R.C.C walletc. |
| 1784 | I/S-1x2x(5.00+1.60)x2.40=31.68 |
| 1785 | O/S-1x2(5.80+2.40)x2.55=41.82 |
| 1786 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1787 | In ground floor |
| 1788 | Supplying all materials, labour, T&P and providing cement concrete M25with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1789 | In ground floor |
| 1790 | Base-1x5.80x2.40x0.125=1.74 |
| 1791 | Slab-1x5.50x2.10x0.13=1.50 |
| 1792 | Wall-1x14.20x0.25x2.40=8.52 |
| 1793 | CONSTRUCTION OF 10000 LTR RCC SUMP |
| 1794 | Earthwork in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to minimum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer in charge. |
| 1795 | Initial lift- 1 x 3.5 x3.50x 1.50 = |
| 1796 | Earthwork in excavation of foundation in stonety earth mixed with gravel within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to minimum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer in charge. |
| 1797 | 1st Extra lift - 1 x 3.5 x3.50x 0.70 = |
| 1798 | Supplying all materials, labour, T&P and providing filling sand including watering, ramming and conveyance of all materials to site. |
| 1799 | 3.50x3.50x0.10= |
| 1800 | (1/3 of the Qnty of Sl.No.1+2) |
| 1801 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 40mm H.G metal including watering, curing and conveyance of all materials to site. |
| 1802 | - 1 x 2.90 x2.90x 0.15 = |
| 1803 | Supplying all materials, labour,T&P and providing cement concrete M25 for RCC work using 12mm HG chips including hoisting,laying,curring and conveyance of all materials to site etc complete. |
| 1804 | Base - - 1 x 2.90 x2.90x 0.20 =1.682 |
| 1805 | Wall - 2 x 2.60x 0.125 x 2.20 = 1.43 |
| 1806 | Wall - 2 x 2.20 x 0.125 x 2.20 = 1.21 |
| 1807 | Slab - 1 x 2.60 x 2.60x 0.13 = 0.878 |
| 1808 | Supplying all materials, labour, T&P and providing brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1809 | 2x2.85x0.125x2.20= |
| 1810 | 2x2.20x0.125x2.20= |
| 1811 | 2x2.35x0.125x2.20= |
| 1812 | 2x1.95x0.125x2.20= |
| 1813 | Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage. |
| 1814 | 1.00 qntl per cum |
| 1815 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor. |
| 1816 | RCC walls |
| 1817 | 2X2.9X0.3=1.74 |
| 1818 | 2.2X2.2=4.84 |
| 1819 | 14X2.6X.13=4.732 |
| 1820 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) including watering,curring and conveyance of all materials to site. |
| 1821 | Inside portion |
| 1822 | Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site. |
| 1823 | Supplying all materials, labour, T&P and futting and fixing 20mm dia MS/CI step iron including supply of necessary C.C(1:2:4) for fixing etc complete as per P.H.D. specification. |
| 1824 | Supplying all materials, labour, T&P and cleaningof debries,uprooging and disposing at a safe distance all complete as per direction of the Engineer in charge |
| 1825 | Sweeper |
| 1826 | FAMILY QUARTER |
| 1827 | A- Internal PH Work |
| 1828 | Supplying all materials, labour,T&Pand providing and fixing to wall or ceiling and floor ChlorinatedPolyvinyl Chloride (C-PVC)pipes(Make-Astral/Supreme/Finolex) conforming to IS:15778,having thermal stability for hot & cold water supply , including all CPVCplain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes &fittings with one step CPVCsolvent cement and testing of joints complete as per direction of Engineer -in-Charge. |
| 1829 | GroundFloor |
| 1830 | 20mm dia C-PVC pipe |
| 1831 | 25mm dia C-PVC pipe |
| 1832 | 32mm dia C-PVC pipe |
| 1833 | In 1st Floor |
| 1834 | 20mm dia C-PVC pipe |
| 1835 | 25mm dia C-PVC pipe |
| 1836 | 32mm dia C-PVC pipe |
| 1837 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge. |
| 1838 | 250mmthick wall in Ground floor |
| 1839 | In 1st Floor |
| 1840 | In 2nd Floor |
| 1841 | Supplying all materials, labour, T&Pand cutting hole in R.C.C floors, roofs, etc upto 19 cm thickfor passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes afterinsertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of theEngineer in charge.in Ground Floor |
| 1842 | In 1st Floor |
| 1843 | Supplying allmaterials, labour, T&P and cutting grooves in pucca floors and walls for takingGI/ PVC pipes and making good the damages as per the direction of the Engineer in charge. In Ground Floor |
| 1844 | In 1st Floor |
| 1845 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all completeas per PH specification and direction of the Engineer in charge |
| 1846 | 250mm to 375mmthick wall |
| 1847 | in 1st Floor to 5th Floor |
| 1848 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge |
| 1849 | 15mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make) |
| 1850 | 20mm dia CP consealed stop cock(Con-CHR-083FTK Jaquar make) |
| 1851 | 15mm dia CP CP Angle stop cock (Jaquar-Con-CHR-053KN) |
| 1852 | 15mm dia CP extension piece |
| 1853 | 15mm dia CP Pillar cock (Jaquar-Con-CHR-011KN) |
| 1854 | 25mm dia G.M or Brass F.W valve (Sakti make) |
| 1855 | 32mm dia G.M or Brass F.W valve (Sakti make) |
| 1856 | 125mm dia CP gratings |
| 1857 | 15mm CP revolving shower with 15mm x 225mm long CP shower arm(Jaquar-OHS-1989) |
| 1858 | Supplying all materials, labour, T&P and fitting and fixing 12.50 litres/10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge |
| 1859 | 10 litres PVC L.L. Cistern (Slimline-white) |
| 1860 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering,watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge |
| 1861 | 1000 Ltr PVC water storage tank (3 Layer White)-on 2nd . Floor |
| 1862 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings (Make-Supreme/Finolex) of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricantby non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge. |
| 1863 | 75mm dia U-PVC SWR pipes |
| 1864 | 75mm U-PVC plain bend |
| 1865 | 110mm dia U-PVC SWR pipes( |
| 1866 | 110mm U-PVC door bend |
| 1867 | 110mm U-PVC door Tee |
| 1868 | 110mm U-PVC plain Tee |
| 1869 | 110mm dia U-PVC offset without ear |
| 1870 | 110mm U-PVC plain bshoe end |
| 1871 | 110mm U-PVC vent cowl |
| 1872 | 110mm dia U-PVC \"P\" trap |
| 1873 | 110mm dia U-PVC socket plain |
| 1874 | 75mm dia U-PVC socket plain |
| 1875 | PVC Clamp |
| 1876 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan conforming to IS:2556-part-3-2004) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x 30mm footrest, fixing 100mm dia HCI ‘P’ or ‘S’ trap (with/without 50mm dia horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc all complete as per specification and direction of the Engineer in charge(Nycer,parryware make) |
| 1877 | 580mm size Orissa pan(Hindware/Parryware/Neycer) |
| 1878 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make),etc all complete as per specification and direction of the Engineer in charge |
| 1879 | 550mm x 400mm size W. H. Basin with Porcelain Pedestal (Parryware/Hindware/Neycer) |
| 1880 | Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge |
| 1881 | 600mm x 450mm size B.E mirror |
| 1882 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 1883 | 600 x 125mm plate glass shelf with CP guard rails( Jaquar -AKP-3577P) |
| 1884 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 1885 | 25mm x 600mm long CP towel rail (Jaquar -ACN-111SM) |
| 1886 | CP towel Ring(Jaquar -ACN-1121N) |
| 1887 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 1888 | CP soap holder( Jaquar -ACN-1131N) |
| 1889 | Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink with outlet at end and weir overflow including fitting and fixing a pair of cast iron or MS brackets painted white, fixing 50mm/40mm dia CP brass waste, fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge |
| 1890 | 600 x 450 x 250mm size S/S kitchen sink (Jayana make ) |
| 1891 | Supplying all materials labour T&P and filling in foundation and plinth with sandwellwatered and rammed including conveyance of all materials to work sitepayment of royalty taxes etc all complete as per direction ofEngineer in charge In ground floor |
| 1892 | 3x1.35x2.10x0.30= |
| 1893 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
| 1894 | 3x1.35x2.10x0.10= |
| 1895 | Supply of all materials & laying the waterproofing material of Dr.Fixit torch shield P3160(3mm)with its primer 2 coats or equivalent water proofing material after drying cleaning the concrete surface over the concrete floor/roof/ balcony/sunken and dado upto 1\"6\" in wall including cleaning,applying and mending as per specification including cost,conveyance,taxes,royalities of all materials to work site etc.all complete as per the direction of the Engineer-in-charge.(Sqm) |
| 1896 | In Ist Floor (sunkeen floor) |
| 1897 | 3x1.35x2.10= |
| 1898 | (sunkeen Wall) |
| 1899 | 3x2x(1.35+2.10)x0.45= |
| 1900 | Supplying all materials, labour, T&P and providing and filling cynder including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1901 | In FirstFloor floor |
| 1902 | 3x1.35x2.10x0.15= |
| 1903 | Supplying all materials, labour, T&P and constructing Gully Trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, Fly ash brickwork in c.m (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat ofneat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size C.I grating etc all complete as per approved drawing, specification and direction of the Engineer in charge |
| 1904 | Gully trap chamber of size 250mmx250mm with R.C.C cover slab |
| 1905 | Supplying all materials, labour, T&P and constructing Inspection Chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6),moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
| 1906 | Inside size 760mm x 760mm x 460mm |
| 1907 | Fitting and fixing RCPC cover slab (0.45m dia) |
| 1908 | EXTERNAL PH WORK |
| 1909 | Supplying all materials, labour, T&P and providing and laying in trenches PVC ASTM pipeof the following nominal bore, tube fittings, testing all complete as per specification and direction of the Engineer in charge |
| 1910 | 50mm dia PVC ASTM Pipe |
| 1911 | Earth work in all kinds of soil within 50 mtr initial lead and 1.5mtr initial lift includingrough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3 mtr in depth and as per direction of the Engineer in charge. |
| 1912 | 25m x 0.45m x 0.60m |
| 1913 | Supplying all materials, labour T&P and fitting and fixing brass/CP/PVC fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer in charge. |
| 1914 | 40mm dia Brass N. R. Valve |
| 1915 | Supplying all materials, labour, T&P and construction of Fullway valve chamber/Stop cock chamber of the following inside size for fullway valve with cement concrete slab (1:2:4) mix , 7.50cm thick, foundation concrete (1:5:10) and inside plastering with cement mortar (1:3) finished with a floating coat of neat cement including curing etc all complete as per approved specification and direction of the Engineer in charge |
| 1916 | Inside size 250mm x 250mm x 560mm |
| 1917 | Supplying all materials, labour, T&P and constructionman hole chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1½:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
| 1918 | Inside size 910mm x 910mm x 910mm |
| 1919 | Addl depth |
| 1920 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class K.B brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
| 1921 | 1.22m dia x 2.10m deep soakway pit |
| 1922 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasingincluding concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. |
| 1923 | 110mm dia u-pvc pipe alround concrete |
| 1924 | Construction of 20 users septic tank |
| 1925 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of theEngineer-in-Charge. |
| 1926 | 3.29mx2.09mx1.50m= |
| 1927 | Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. |
| 1928 | 3.29mx2.09mx0.63m= |
| 1929 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1930 | In ground floor |
| 1931 | 3.29mx2.09mx0.08m= |
| 1932 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12m size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1933 | In ground floor |
| 1934 | 3.29mx2.09mx0.15m= |
| 1935 | 3.13mx1.13mx½(0.03m+0.13m)= |
| 1936 | Supplying all materials, labour, T&P and providing brick work with fly ashbricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1937 | In F&P |
| 1938 | 2(3.09m+1.13m)0.38mx0.70m= |
| 1939 | 2(2.83m+1.13m)0.25mx1.30m= |
| 1940 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1941 | In ground floor |
| 1942 | Inside |
| 1943 | (1.95m+1.87m)1.13m= |
| 1944 | 2x2.33mx½(1.95m+1.87m)= |
| 1945 | Outside |
| 1946 | 2(3.09m+1.89m)0.70m= |
| 1947 | 2(2.83m+1.63)1.43m= |
| 1948 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1949 | In ground floor |
| 1950 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1951 | R.C.C floor androofslabs |
| 1952 | In ground floor |
| 1953 | 2.30mx1.10m= |
| 1954 | 2(2.86m+1.66m)0.10m= |
| 1955 | Supplying all materials, labour, T&P and providing M.Sreinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1956 | In ground floor |
| 1957 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1958 | In ground floor |
| 1959 | 2.86mx1.66mx0.10m= |
| 1960 | Supplying all materials, labour, T&P and providing,fitting and fixing 100mm x 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification anddirection of the Engineer in charge |
| 1961 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls ofman hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 1962 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 1963 | 2(3.29m+1.89m)0.10mx0.70m= |
| 1964 | 2(3.29m+1.63m)x0.23mx1.20m= |
| 1965 | Construction of 6000 Liters RCCUGR WITH PUMPING ARRAGEMENTof Inside size- 3.50 X 2.50 X1.80m |
| 1966 | Earth work in All kinds of soil and gravels mixed with stone and boulder not exceeding 0.014 Cum in volume within 50m initiallead and 1.5 m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per specification approved by the Department. |
| 1967 | UGR - 1x2.950x2.65x1.50 |
| 1968 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer incharge. |
| 1969 | UGR -1x2.950x2.65x0.15 |
| 1970 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 1971 | UGR -1x2.950x2.65x0.15 |
| 1972 | Supplying all materials, labour,T&P and providing cement concrete M25 for RCC work using 12mm HG chips including hoisting,laying,curring and conveyance of all materials to site etc complete. |
| 1973 | Base slab 1x2.95x2.65x0.15 |
| 1974 | Long wall - 2x2.70x0.15x1.50 |
| 1975 | Short wall- 2x2.10x0.15x1.50 |
| 1976 | Roof Slab - 1x2.70x2.40x0.15 |
| 1977 | Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage. |
| 1978 | @ 100 kg / cum = |
| 1979 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor. |
| 1980 | RCC floor roof, chajja etc |
| 1981 | Roof Slab- 1x2.40x2.10 |
| 1982 | In Sides - 2x(2.4+2.10)x1.50 |
| 1983 | OutSides - 2x(2.7+2.40)x1.50 |
| 1984 | Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) overCC workincluding watering curring and conveyance of all materialsto site. |
| 1985 | Bottom - 1x2.40x2.10 |
| 1986 | Wall inside - 2x(2.4+2.10)x1.50 |
| 1987 | Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site. |
| 1988 | Quantity same as item No-4 |
| 1989 | Providing fitting and fixing CI/MS step iron including fixing to walletc. complete |
| 1990 | Providing fitting and fixing RCPCcoveretc complete as per direction of Engineer-in-charge |
| 1991 | Supply all materials, labour, T&P and providing, fitting and fixing of centrifugal pump set to run on 3phase/1phase line voltage ranging from 320 volt to 450 volt with suitable control pannel, jointing with GI/ PVC/ HDPE pipes electrification, testing,commissioning,trial running,conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge. |
| 1992 | 3HP 3 phase Monoblock Centrifugal pump set. |
| 1993 | DOL control panel |
| 1994 | Labour charges for lowering, testing, commissioning & transportation to site etc. |
| 1995 | 2.50mm Sqm Submersible flat cable |
| 1996 | Steel rope with cover |
| 1997 | 20mm dia rigid U-PVC pipe |
| 1998 | 50mm dia HDPE pipe |
| 1999 | SINGLE QUARTER |
| 2000 | A- Internal PH Work |
| 2001 | Supplying all materials, labour,T&Pand providing and fixing to wall or ceiling and floor ChlorinatedPolyvinyl Chloride (C-PVC)pipes(Make-Astral/Supreme/Finolex) conforming to IS:15778,having thermal stability for hot & cold water supply , including all CPVCplain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes &fittings with one step CPVCsolvent cement and testing of joints complete as per direction of Engineer -in-Charge. |
| 2002 | GroundFloor |
| 2003 | 20mm dia C-PVC pipe |
| 2004 | 25mm dia C-PVC pipe |
| 2005 | 32mm dia C-PVC pipe |
| 2006 | 40mm dia C-PVC pipe |
| 2007 | In 1st Floor |
| 2008 | 25mm dia C-PVC pipe |
| 2009 | 32mm dia C-PVC pipe |
| 2010 | 40mm dia C-PVC pipe |
| 2011 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge. |
| 2012 | 250mmthick wall in Ground floor |
| 2013 | In 1st Floor |
| 2014 | Supplying all materials, labour, T&Pand cutting hole in R.C.C floors, roofs, etc upto 19 cm thickfor passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes afterinsertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of theEngineer in charge.in Ground Floor |
| 2015 | Supplying allmaterials, labour, T&P and cutting grooves in pucca floors and walls for takingGI/ PVC pipes and making good the damages as per the direction of the Engineer in charge. In Ground Floor |
| 2016 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all completeas per PH specification and direction of the Engineer in charge |
| 2017 | 250mm to 375mmthick wall |
| 2018 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge |
| 2019 | 15mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make) |
| 2020 | 20mm dia CP consealed stop cock(Con-CHR-083FTK Jaquar make) |
| 2021 | 15mm dia CP CP Angle stop cock (Jaquar-Con-CHR-053KN) |
| 2022 | 15mm dia CP extension piece |
| 2023 | 15mm dia CP Pillar cock (Jaquar-Con-CHR-011KN) |
| 2024 | 25mm dia G.M or Brass F.W valve (Sakti make) |
| 2025 | 32mm dia G.M or Brass F.W valve (Sakti make) |
| 2026 | 125mm dia CP gratings |
| 2027 | 15mm CP revolving shower with 15mm x 225mm long CP shower arm(Jaquar-OHS-1989) |
| 2028 | Supplying all materials, labour, T&P and fitting and fixing 12.50 litres/10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge |
| 2029 | 10 litres PVC L.L. Cistern (Slimline-white) |
| 2030 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering,watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge |
| 2031 | 1000 Ltr PVC water storage tank (3 Layer White)-on 2nd . Floor |
| 2032 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings (Make-Supreme/Finolex) of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricantby non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge. |
| 2033 | 75mm dia U-PVC SWR pipes(Supreme/Finolex) |
| 2034 | 75mm U-PVC plain bend |
| 2035 | 110mm dia U-PVC SWR pipes(Supreme/Finolex) |
| 2036 | 110mm U-PVC door bend |
| 2037 | 110mm U-PVC door Tee |
| 2038 | 110mm U-PVC plain Tee |
| 2039 | 110mm dia U-PVC offset without ear |
| 2040 | 110mm U-PVC plain bshoe end |
| 2041 | 110mm U-PVC vent cowl |
| 2042 | 110mm dia U-PVC \"P\" trap |
| 2043 | 110mm dia U-PVC socket plain |
| 2044 | 75mm dia U-PVC socket plain |
| 2045 | PVC Clamp |
| 2046 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan conforming to IS:2556-part-3-2004) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x 30mm footrest, fixing 100mm dia HCI ‘P’ or ‘S’ trap (with/without 50mm dia horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc all complete as per specification and direction of the Engineer in charge(Nycer,parryware make) |
| 2047 | 580mm size Orissa pan(Hindware/Parryware/Neycer) |
| 2048 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make),etc all complete as per specification and direction of the Engineer in charge |
| 2049 | 550mm x 400mm size W. H. Basin with Porcelain Pedestal (Parryware/Hindware/Neycer) |
| 2050 | Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge |
| 2051 | 600mm x 450mm size B.E mirror |
| 2052 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 2053 | 600 x 125mm plate glass shelf with CP guard rails( Jaquar -AKP-3577P) |
| 2054 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 2055 | 25mm x 600mm long CP towel rail (Jaquar -ACN-111SM) |
| 2056 | CP towel Ring(Jaquar -ACN-1121N) |
| 2057 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 2058 | CP soap holder( Jaquar -ACN-1131N) |
| 2059 | Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink with outlet at end and weir overflow including fitting and fixing a pair of cast iron or MS brackets painted white, fixing 50mm/40mm dia CP brass waste, fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge |
| 2060 | 600 x 450 x 250mm size S/S kitchen sink (Jayana make ) |
| 2061 | Supplying all materials labour T&P and filling in foundation and plinth with sandwellwatered and rammed including conveyance of all materials to work sitepayment of royalty taxes etc all complete as per direction ofEngineer in charge In ground floor |
| 2062 | 3x1.20x1.20x0.30= |
| 2063 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
| 2064 | 3x1.20x1.20x0.10= |
| 2065 | Supplying all materials, labour, T&P and constructing Gully Trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, Fly ash brickwork in c.m (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat ofneat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size C.I grating etc all complete as per approved drawing, specification and direction of the Engineer in charge |
| 2066 | Supplying all materials, labour, T&P and constructing Inspection Chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6),moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
| 2067 | Inside size 760mm x 760mm x 460mm |
| 2068 | Fitting and fixing RCPC cover slab (0.45m dia) |
| 2069 | EXTERNAL PH WORK |
| 2070 | Supplying all materials, labour, T&P and providing and laying in trenches PVC ASTM pipeof the following nominal bore, tube fittings, testing all complete as per specification and direction of the Engineer in charge |
| 2071 | 50mm dia PVC ASTM Pipe |
| 2072 | Earth work in all kinds of soil within 50 mtr initial lead and 1.5mtr initial lift includingrough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3 mtr in depth and as per direction of the Engineer in charge. |
| 2073 | 25m x 0.45m x 0.60m |
| 2074 | Supplying all materials, labour T&P and fitting and fixing brass/CP/PVC fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer in charge. |
| 2075 | 40mm dia Brass N. R. Valve |
| 2076 | Supplying all materials, labour, T&P and construction of Fullway valve chamber/Stop cock chamber of the following inside size for fullway valve with cement concrete slab (1:2:4) mix , 7.50cm thick, foundation concrete (1:5:10) and inside plastering with cement mortar (1:3) finished with a floating coat of neat cement including curing etc all complete as per approved specification and direction of the Engineer in charge |
| 2077 | Inside size 250mm x 250mm x 560mm |
| 2078 | Supplying all materials, labour, T&P and constructionman hole chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1½:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
| 2079 | Inside size 910mm x 910mm x 910mm |
| 2080 | Addl depth |
| 2081 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class K.B brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
| 2082 | 1.22m dia x 2.10m deep soakway pit |
| 2083 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasingincluding concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. |
| 2084 | 110mm dia u-pvc pipe alround concrete |
| 2085 | Construction of 20 users septic tank |
| 2086 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of theEngineer-in-Charge. |
| 2087 | 3.29mx2.09mx1.50m= |
| 2088 | Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. |
| 2089 | 3.29mx2.09mx0.63m= |
| 2090 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 2091 | In ground floor |
| 2092 | 3.29mx2.09mx0.08m= |
| 2093 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12m size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 2094 | In ground floor |
| 2095 | 3.29mx2.09mx0.15m= |
| 2096 | 3.13mx1.13mx½(0.03m+0.13m)= |
| 2097 | Supplying all materials, labour, T&P and providing brick work with fly ashbricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 2098 | In F&P |
| 2099 | 2(3.09m+1.13m)0.38mx0.70m= |
| 2100 | 2(2.83m+1.13m)0.25mx1.30m= |
| 2101 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 2102 | In ground floor |
| 2103 | Inside |
| 2104 | (1.95m+1.87m)1.13m= |
| 2105 | 2x2.33mx½(1.95m+1.87m)= |
| 2106 | Outside |
| 2107 | 2(3.09m+1.89m)0.70m= |
| 2108 | 2(2.83m+1.63)1.43m= |
| 2109 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 2110 | In ground floor |
| 2111 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 2112 | R.C.C floor androofslabs |
| 2113 | In ground floor |
| 2114 | 2.30mx1.10m= |
| 2115 | 2(2.86m+1.66m)0.10m= |
| 2116 | Supplying all materials, labour, T&P and providing M.Sreinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 2117 | In ground floor |
| 2118 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 2119 | In ground floor |
| 2120 | 2.86mx1.66mx0.10m= |
| 2121 | Supplying all materials, labour, T&P and providing,fitting and fixing 100mm x 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification anddirection of the Engineer in charge |
| 2122 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls ofman hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 2123 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 2124 | 2(3.29m+1.89m)0.10mx0.70m= |
| 2125 | 2(3.29m+1.63m)x0.23mx1.20m= |
| 2126 | Borewell |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy