Tender For Special Repair To Mes Installation At Palampur Mil Station.; 1 Excavation in trenches,not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation,etc or for shafts,wells,cesspits,manholes,pier holes,etc n exc 10 sq m on plan and getting out any type of soil complete all as specified and directed. 2 Returning, filling in,(soil) including spreading, levelling, watering and well ramming in layers not exc. 25cm thick in any type of soil,complete all as specified and directed. 3 Removal of excavated materials (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified anddirected. 4 Takingup ordownGItubing including all fittings from trenches, wall, floor etc including cleaning by roding for refixing or removing to store for safe custody/reuse or disposal under schedule for credit and all as specified of size 50 mm bore complete all as specified and directed. 5 All as per the description of Serial item No. 4 here-in-before but for of size 80mm bore, complete all as specified and directed. 6 All as per the description of Serial item No. 4 here-in-before but for of size 100mm bore, complete all as specified and directed. 7 S&F galvanised iron water tubing 50mm bore, medium grade with all fittings such as bends, elbows, tees, short pieces, connector with (ISI marked), back nuts, dimishing pieces, caps, plugs and union etc and laying in trenches/floor complete all as specified and directed.Note:- (a) Earth work shall be measured & paid under relevant item.(b)The cost of new fitting alongwith cutting, threading as required shall be deemed to be included in the quoted rates. 8 All as per the description of Serial item No. 7 here-in-before but for of size 80mm bore, complete all as specified and directed. 9 All as per the description of Serial item No. 7 here-in-before but for of size 100mm bore, complete all as specified and directed. 10 Supply, installation, connecting and testing sluice valve 100 mm bore cast iron long body typeclass-PN-1.6 with flanged ends drilled pipes, ISI marked (IS:14846:2000), having brass spindle with iron wheel at top complete with nuts, bolts, washers, rubber gasket, etc complete as specified and directed. 11 All as per the description of Serial item No. 10 here-in-before but for of size 200mm bore, complete all as specified and directed. 12 All as per the description of Serial item No. 10 here-in-before but for of size 250mm bore, complete all as specified and directed. 13 Taking up or down DI pipe line including all fittings from trenches etc including cleaning by roding for refixing or removing to store for safe custody or disposal under schedule of credit and all as specified of size 250mm bore complete all as specified and directed. 14 All as per the description of Serial item No. 13 here-in-before but for of size 200mm bore, complete all as specified and directed. 15 All as per the description of Serial item No. 13 here-in-before but for of size 150mm bore, complete all as specified and directed. 16 Supply, laying, jointing and testing of DI pipe 250 mm bore with flanged type and socket ends, centrifugally cast class-K-9 suitable for tyton joints, in any length, laid in trenches/pillars complete all as specified and directed. 17 All as per the description of Serial item No. 16 here-in-before but for of size 200mm bore, complete all as specified and directed. 18 All as per the description of Serial item No. 16 here-in-before but for of size 150mm bore, complete all as specified and directed. 19 Material and labour DI fittings such asbends (any type radius and angle ) tapers any type , bends , tee pieces single branch Y junction double branch , cross (all type socket as spigot and socket etc) ,collar , caps and plugs suitable for spigot and socketpipes upto 250mm bore including rubber gasket completeall as specified and directed. 20 All as per the description of Serial item No. 19 here-in-before but for of size 200mm bore, complete all as specified and directed. 21 All as per the description of Serial item No. 19 here-in-before but for of size 150mm bore, complete all as specified and directed. 22 Dismantling of existing brick masonry valve pit 750x750x750mm including stacking serviceable material for credited to contractor and removal of unserviceable material from site complete all as specified and directed. 23 M&L construction of valve pit of inner sizes 750x750x750mm brick masonry construction complete with mild steel sheet cover 3.15mm thick and angle iron frame of size 40x40x60mm duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and including locking arrangement and lifting handle all as specified and shown on drawing and all internal surface, external surface upto 15cm below normal ground level of brick masonry shall be plastered 15mm thick in CM 1:4, finished the surface even and smooth including necessary excavation and earth work in any type of soil and PCC work all as per TD drg complete all as specified and directed. 24 M&L brick work with sub-class B bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 including demolition of old unsv brick masonry complete all as specified and directed. 25 M&L PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. 26 Rendering 15mm thick plaster on brick work/concrete surface in cement mortar 1:4 finished even and fair without using extra cement, complete all as specified and directed. 27 Taking down cement plaster including tiles of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc.complete all as specified and directed. 28 Rendering 10mm thick plaster in cement mortar 1:6 on fair faces of brick work or concrete surfaces of walls, finished even and smooth without using extra cement, complete all as specified and directed. 29 Supply only liquid water proofing compound complete all as specified and directed. 30 M&L plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate cast in situ in lintels up to 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, water through and the like including weathering, slightly rounded or chamfered angles and throating including use of form work (straight or curved) complete all as specified & directed. 31 M&L Glazed ceramic coloured tiles in vertical surface 350mm x 250mm x 7mm/450mm x 350mm x 7mm/450x300x7mm/600x300x7mm thick set and jointed in neat cement slurry,pointed in white or coloured cement to match the colour of tiles, over and including 10mm thick backing coatin CM 1:4 to receive tiles complete all as specified and directed. 32 S&F 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including fixing fittings such as GInipple for inlet, outlet, washout and overflow etc,including 20mm size ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe including dismantling complete all as specified and directed. 33 Supply, install, testing & commissioning CPRI approved LT panel board, outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 Hz, AC Supply system having burbars chamber with copper bus bars duly insulated by insulation of RYB colour 300 amps rating mounted on porcelain insulators. The panels shall be factory made, double door, made out of 3.15mmthick MS sheet (CRCA) total enclosed dust, vermin & rust proof front operated, front & rear opening with locking arrangement fixed with MS angle iron frame of size 40x40x6mm and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable etc as directed at site and comprising the following:-(a)MCCB 125A, 4P, 415 volts AC Supply, thermal magnetic release type/36 KA- 01 No(b)MCCB 63A, 4P, 415 Volt 25KA thermal magnetic release type- 03 Nos(c)Panel mounted multi function meter for measuring voltage (0-500 volts), current (0-100 amps) and freqency-01 No.(d)RYB neon indicating lamp panel mounting type (Set of three)- 01 No(e)Internal wiring of the panel board with single core copper cable PVC insulated of suitable size and control fuses.(f)Cable entry gland and two no earthing terminal 34 Supply, install, testing & commissioning CPRI approved LT panel board, outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 Hz, AC Supply system having burbars chamber with copper bus bars duly insulated by insulation of RYB colour 200 amps rating mounted on porcelain insulators. The panels shall be factory made, double door, made out of 3.15mmthick MS sheet (CRCA) total enclosed dust, vermin & rust proof front operated, front & rear opening with locking arrangement fixed with MS angle iron frame of size 40x40x6mm and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable etc as directed at site and comprising the following:-(a)MCCB 250A, 4P, 415 volts AC Supply, thermal magnetic release type/36 KA- 01 No(b)MCCB 100A, 4P, 415 Volt 25KA thermal magnetic release type- 0 No(c)MCCB 63A, 4P, 415 volt 25KA thermal magnetic release type - 03 Nos(d)Timelite- 110A 3 Pole, 230V Digital time switch. Make: Indiasian Cat Part No. TL10080-01 Nos(e)Panel mounted multi function meter for measuring voltage (0-500 volts), current (0-100 amps) and freqency-01 No.(d)RYB neon indicating lamp panel mounting type (Set of three)- 01 No(e)Internal wiring of the panel board with single core copper cable PVC insulated of suitable size and control fuses.(f)Cable entry gland and two no earthing terminal 35 Supply, installation, commissioning and testing LT feeder pillar box outdoor type of factory fabricated made out of MS sheet of thickness 3.15mm with front door openable with locking arrangement mounted on angle iron legs made out of angle iron size 40x40x6mm, 1 mtr long, 0.50 mtr above ground level and 0.50 mtr embedded in PCC blocks of size 0.30x0.30x0.30 mtr- 04 Nos, duly painted with two coats of synthetic enamel paint over a coat of red oxide complete with 200 amps rated copper bus bar LED phase indicators, suitable for 3 phase 4 wire supply system with MCCB 63 Amp 4 pole breaking capacity 16 KA- 01 No, duly drilled holes for cable connection mounted on epoxy based post insulators all as required at site, complete all as specified including taking down the unsv feeder pillar box. 36 M&L earthing complete with galvanised steel earth plate electrode 60cmx60cm/6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 32x6mm size (as earth lead strip), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 40mm bore including provn of concrete pit in PCC M-15 type B1 using 20mm graded crushed stone aggregate with 40mm thick cover of reinforced cement concrete M-15 reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 02 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distancne not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion including taking down the unsv earthing. 37 S&F formatery/equiment history sign boards of size not less than 900x600mm rectangular type with 2mm thick MS sheet plain type made out of angle iron channels frame background and equipment history details (i.e. Name, make, Srl No., capacity of equipment vintage, SM MES No.) with high intensity retro reflective sheet letter as specified colour (Blue and white) complete all as specified and directed. 38 Excavation post holes (or similar holes) in any type of soil each n exc 0.50 cu.m,getting out,returning,filling on and ramming earth or broken rubble mixed with earth around,in layers not exceeding 25cm, complete all as specified and directed. 39 S&F hand rail, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc. and similar work conforming to Fe-290 Gde E-165 including two coats of paint as directed with ove a coating of red oxide primer all as directed. 40 Supply only chain link fencing 3.6mm dia for GI wire and minimum 1mm thick vinyl coating, 50mm x 50mm mesh size all as approved and directed.Note: (i)The dia meter of the mesh after PVC coating shall be 5.6mm(ii)The PVC coating shall be green in colour.(iii)The GI chain link mesh with PVC coating shall be weighed for the purpose of payment. 41 Fixing only GI wire chain link fencing including line wires, any mesh, size and type to any type of standards, rails, strain in bolts etc including provision of binding wire complete all as specified and driected. 42 M&L PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation for transformer etc complete all as specified and directed. 43 Supply and spread grated coarse aggregate of 40mmto 63mm nominal size around outdoor transformer and two/four pole structure/panel complete all as specified and directed.