| 1 | Taking down carefully (copper/aluminum) unsv point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point ,socket point or power point includingfixture and fitting such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing material to store for keeping in safe custody or for taking credit (credit for above items should be made asper conditions seperately) and making good the disturbed surfaces of wall/floor or ceiling to match with existing surfaceand finishing the surfaces with distemper/white washing/colour washing as per existing complete all as specified and directed. |
| 2 | Taking down carefully by unscrewing from main switch boards/cut out boxes/MCB DBs / complete sealing the cable end and making good disturbed surface by walls etc. |
| 3 | Taking down carefully by unscrewing from fitting and fixtures such as ceiling fittings,bulk head fittings, tube light fittings, street light , floodLED lights etc all as specified and directed. |
| 4 | M&L for Point wiring with PVC insulated and unsheathed multistranded FRLS copper conductor single core 1.5sqmm (nominalarea) cable using approved colour code as per IS drawing in and incl PVC casing and capping with all accessories suitable forPVC type fitment including provision for fixing of PVC boxes of suitable size as per site reqmt complete alongwith copper earth wire PVC insulated & unsheathed multistranded (FRLS) copper conductor cableof size 1.5sqmm as continous earth wire connected to common earth and erth dolly complete all as specified and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed. |
| 5 | (a) One Light point /Fan point controlled by oneswitch |
| 6 | (b)One 3 pin socket outlet 5Amps on the same board with other switches |
| 7 | (c)One 3 pin 5 Amp socket out let controlled by one switch onindependent board |
| 8 | (d)One bell /Buzzer point controlled by one bellpush 5 amp on the same board with other switches or independent |
| 9 | (e) One light point controlled bytwo 2-way switch with cable 1.5 sqmm |
| 10 | M&L for Point wiringfor power point with PVC insulated and unsheathed multistranded FRLS copper conductor single core 2.5sqmm (nominalarea) cable using approved colour code as per IS drawing in and incl PVC casing and capping with all accessories suitable forPVC type fitment including provision for fixing of PVC boxes of suitable size as per site reqmt andthickness as per IScomplete alongwith copper earth wire PVC insulated & unsheathed multistranded (FRLS) copper conductor cableof size 2.5 sqmm as continous earth wire connected to common earth and erth dolly complete all as specified and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed. |
| 11 | All as per item No 5 above but wiring with 4.0 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 4.0Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as continous earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch. |
| 12 | M & L for Switch piano flush type single pole, one way 5 Amp 230 V complete all as specified and directed. |
| 13 | M & L for Socket outlet 2 in 1, 3 pin, 5A complete all as specified and directed. |
| 14 | M & L for Switch socket combination 2 in 1, 3 pin, 5Amp flush type universal complete all as specified and directed. |
| 15 | M & L for Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and directed. |
| 16 | Supply and fixin repair stepped type electronic fan refulator flush type on the existing phenolic laminated sheet etc. complete all as specified and directed. |
| 17 | M&L for ceiling rose, 2 to 3 terminalPVC/ polucarbonate, isolated body type suitable for AC 230volts complete all as specified and |
| 18 | M & L for switch Piano type 2 way 5 amp 230 volts complete all as specified and directed. |
| 19 | M & L for Bell push 5 Amp 230 volts complete all as specified and directed. |
| 20 | M & L for BellAC 230 Volts, single pole complete all as specified and directed. |
| 21 | S & F industrial type plug & socket board SP & N enclosure with 2 pole and earth metal plug & socket with 20 Amp MCB SP, complete all as specified and directed. |
| 22 | Supply and fixin repair of Lamp holder, white Polycarbonate body, with back plate suitable for batten fittings fixed in position & connecting complete all as specified and directed. |
| 23 | Supply and fixin repair of bell musical type AC 230 Volts, including connecting complete all as specified and directed. |
| 24 | S&F energy efficient LED tube light fitting integrated batten type with built in LED Chip & integral LED driver 20 watt, channel housing & diffuser of length 1200 mm (approx.) with all accessories, fixing arrangement internally pre-wired,fixed in position & connecting complete all as specified and directed. |
| 25 | S&F energy efficient LED tube light fitting integrated batten type with built in LED Chip & integral LED driver 10 watt, channel housing & diffuser of length 600mm (approx) with all accessories, fixing arrangement internally pre-wired fixed in position & connecting ccomplete all as specified and directed. |
| 26 | Supply and fixing in repair recess mounted LED luminaire with full diffuser 36 watt of 2x2 grid for new age work space, powder coated luminaire with minimum 100lm/watt efficiency,25000 to 50000 working hours and 6500CCT complete all as specified and directed. |
| 27 | S & F bulkhead fitting 10watt made die cast aluminium housing with complete assembly and PC opal diffuser suitable for surface/wall mounted dust and water resistant complete all as specified and directed. |
| 28 | Taking down carefully (copper/aluminium) submain wiring complete of any type (batten/surface conduit or concealed ) for socket point or power point complete with all fittings such as swiches sockets pendants etc complete and making good distuebed surface of wall,floor or ceiling with plaster of tiles or roof treatment etc and finishing the surface with distemper white washing/colour washing to match with the existing surface complete all as specified and directed. |
| 29 | M&L Sub main wiring usingPVC insulated and unsheathed multistranded FRLS copper conductorcable using approved colour code as per IS drawing in and incl PVC casing and capping with all accessories and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete asspecified and as directed by Engr-in-chargeof the following sizes of cables. . |
| 30 | Using two single corePVC insulatedFRLS cable 4 sqmm copper conductor multi stranded and 4.0 sqmm copper conductor insulated cable using as earth wireNote :2 runs of 4sqmm copper cable & 1 run of 4.0sqmm copper cable in and including 20mm PVC conduit shall be measured as one unit |
| 31 | Using two single corePVC insulatedFRLS cable 6 sqmm copper conductor multi stranded and 6.0 sqmm copper conductor insulated cable using as earth wireNote :2runs of 6sqmm copper cable & 1 run of 6.0 sqmm copper cable in and including 25mm PVC conduit shall be measured as one unit |
| 32 | Using two single corePVC insulatedFRLS cable 2.5 sqmm copper conductor multi stranded and 2.5 sqmm copper conductor insulated cable using as earth wireNote :2 runs of 2.5sqmm copper cable & 1 run of 2.5 sqmm copper cable in and including 20mm PVC conduit shall be measured as one unit |
| 33 | M & L for distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 8 way with 100 Amps rated copper busbar, neutral bar, earth bar and cable ties for cable management,reversible door for for IP 43 , single pole and neutral 250 Volts, flush to wall complete with IP 43 protection complete all as specified and directed. |
| 34 | M & L for distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 12 way with 100 Amps rated copper busbar, neutral bar, earth bar and cable ties for cable management,reversible door for for IP 43 , single pole and neutral 250 Volts, flush to wall complete with IP 43 protection complete all as specified and directed. |
| 35 | M&L for MCB single pole & neutral240 volt C curve 10 KA (32 to 63) Amps capacity IP 20complete all as specified and directed. |
| 36 | M&L for MCB single pole,5 to 30 Amp 240 volt B curve 10 KA, IP 20complete all as specified and directed. |
| 37 | M&L for MCB TP (25 to 63 Amp)240 volt C curve 10 KA (32 to 63) Amps capacity IP 20 complete all as specified and directed. |
| 38 | Earthing comple with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire mm as 4.0mm dia bymeans of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electricalplate no.3 includingearth pit in PCC concrete 1:2:4 type B-1,Cast iron cover 10mm thick hinged to CI frame, excavation and earth work in any type of soil and including protectionpipe 15mm dia and water pipe GI tubing 20mmlight grade with funnel and wire mesh connected to earthing test point complete all as specified and directed. Note: (i) Rates are inclusive of 7.5m long GI earth wire 4.0mm dia (ii) Rates of CI frame, RCC Pit cover,funnel and wire mesh included in the cost of item. |
| 39 | Supply and fix in repair 35W LED building security light luminaire complete with pressure die cast aluminium housing and primatic poly carbonate cover to ensure better unformity of light distribution fixed on bldg wall surface including provision of GI pipe bracket complete with clamp nuts bolts and washers and making good the disturbed surface of wall complete all as specified and directed. |
| 40 | Supply and fix in repair LED power supply driver suitable for Primary:220-240 VAC, 50/60Hzsuiatble for 40watt post top fitting Secondary: constant current DC:300mA with thermal, overload and short circuit protection including taking out old/unsv complete all as specified and directed. |
| 41 | Supply and fix in repair capacitor 2.5 MFD AC 230 Volt 50 HZ, complete all as specified and directed. |
| 42 | Supply and fix of single phase two wire direct connected meter type SARAL, 230/240 V (L-N), Rating 5-30 A, CL.1, 50 Hz ± 5%,IP 54, protective class II, with Advanced anti-tamper capability– prevention, detection and deterrence, complete with protection cover Meter must comply following points :Standards IS 13779, IEC 62052-11, IEC 62053-21, IS 15959, DLMS Indian Companion Standard Dimensions (W x H x D) 95 x 130 x 60mm (approx.) Data storage : Midnight energy 35 days for 2 parameters load survey more than 150 days (30min. IP) upto 5 parameters, events up to 300 events, compartment wise history 12 billing periods. Communication: IEC 62056-21 physical port for local communication, Optional RS 232 port over micro USB for remote communication. Note: Rates are inclusive of polycarbonate Protection cover. |
| 43 | S & F Decorative, wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LED lamp B22 base cool day light LED ball lamp complete with fixing arrangement duly internally pre-wired,fixed in position & connecting complete all as specified and directed. |
| 44 | Supply & Fixing Bracket made out of GI light grade pipe of 40/35 mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos MS clamp 50x6mm and 04 sets of nuts, bolts and washers including painting with two coats of synthetic enamel paint over a red oxide primer including dismanting existing old and unservicess security light complete all as specified and directed. |
| 45 | S&F in repair PVC casing caping of min 25 mm diaexclusive of boxes (junction/ terminals) but inclusive of all tees, bends, elobows, reducers, bell mouth tube ends and fixing accessories such as coupler, lock nuts, saddles, pipe hook etcto be fixed on surface for dressing of wiring in neat presentable condition by proper relaying of existing PVC cables including removing of cables/ wires and relaying after fixing of new casing capping including taking down old u/s complete all as specified and directed. |
| 46 | Supply and fix in repair round recess mounted LED luminaire with full diffuser 15/16 watt suitable for opearting voltage 220-240VAC and inbuilt driver, powder coated luminaire with minimum 100lm/watt efficacy ,25000 to 50000 working hours and 6500CCT complete all as specified and directed. |
| 47 | Supply and fix in repair square recess mounted LED luminaire with full diffuser 15/16 watt suitable for opearting voltage 220-240VAC and inbuilt driver, powder coated luminaire with minimum 100lm/watt efficacy, 25000 to 50000 working hours and 6500CCT complete all as specified and directed. |
| 48 | Supply and fix in repair round recess mounted LED luminaire with full diffuser 24 watt suitable for opearting voltage 220-240VAC and inbuilt driver, powder coated luminaire with minimum 100lm/watt efficacy, 25000 to 50000 working hours and 6500CCT complete all as specified and directed. |
| 49 | S & F in repair LED bulb 9 watt,230 volts complete all as specified and directed. Make:Wipro / CG / Bajaj / Havells / Philips |
| 50 | S&F in repairs laminated hylam sheet cover, ISI marked with CM/L no., cut with grooves for mounting of fittings like switches, sockets, fan regulators etc. including fixing in loc with new galvanised screw and cup washer complete all as specified and directed of following sizes:- |
| 51 | 11 x 13 inches |
| 52 | 9 x 11 inches |
| 53 | 5 x 8 inches |
| 54 | 5 x 5 inches |
| 55 | Supply and fix in repair LED Reading light 3watt suitable for 220-240volts, 50hz supply dust and water resistant, minimum 100lm/watt efficacy, 25000 to 50000 working hours and minimum 5000 to 5700CCT, including taking out old/unsv complete all as specified and directed. |
| 56 | Attending electrical complaints of domestic areadeploying experienced electrician and helper and rectification of complaints to the entire satisfaction of Engineer-In-Charge and users.Note:-(i) For rectification of complaints if any electric itemsrequired to be replaced the same shall be measured and paid seperately under \"supply and fixing\" items.(ii) Electrician engaged by contractor for attending complaints and rectification of electrification complaints. |
| 57 | M & L for distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 4way with 100 Amps rated copper busbar, neutral bar, earth bar and cable ties for cable management, reversible door for IP 43 & IP 54, single pole and neutral 250 Volts, flush to wall complete with IP 54 protection complete all as specified and directed. |
| 58 | Taking down carefully ceiling fan / exhaust fan / cabin fan / wall mounted fan by disconnecting electric connection for carrying outrepairing such as rewinding, replacement of defective spare part, over hauling and painting etc as required and re-fixing in the same position after carry out the repairs works, and connecting complete all as specified and directed.Note:- repairing such as rewinding, replacement of defective spare part, connecting wire, over hauling and painting etc will be measured & paid separately under subsequent items. |
| 59 | M & L for rewinding of ceiling fanof any make by dismantling the ceiling fan, removing shaft, bearing and bushing, removing the burnt copperwinding from the slots, cleaning slot, replacement of defective nut bolts washer etc and rewinding of fan motor using appropriate gauge/size super enameled copper winding wire thermal class-E, including varnishing and reassembling. Providing three core copper cable PVC insulated multistranded 0.5mm 30cm length for connection of fan from ceiling rose and testing of fan complete all as specified and directed. Rewinding should be carried out for the following size of ceiling fan:- |
| 60 | (a) 1200mm sweep |
| 61 | (b) 1400 mm sweep |
| 62 | M & L for rewinding of exhaust fanmotor of any make by dismantling the exhaust fan, removing shaft, bearing and bushing, removing the burnt copperwinding from the slots, cleaning slot, replacement of defective nut bolts washer etc and rewinding of fan motorusing appropriategauge/size super enameled copper winding wire thermal class-E, including varnishing, applying cotton tape and reassembling complete. Providing twin core copper cable 30cm length for connectionand testing of fan completeall as directed by the Engineer-in-Charge. Rewinding should be carried out for the following size of exhaust fan :- |
| 63 | (a) 450mm sweep |
| 64 | (b) 300mm sweep |
| 65 | (c) 200mm sweep |
| 66 | M & L for rewinding of pedestal fan motor of any make by dismantling the pedestal fan, removing shaft, bearing and bushing, removing the burnt copper winding from the slots, cleaning slot, replacement of defective nut bolts washer etc and rewinding of fan motor using appropriate gauge/size super enameled copper winding wire thermal class-E, including varnishing ,applying cotton tape and reassembling complete. Testing of fan should be carried out to entire satisfaction of Engr-in-charge. The size of pedestal fan for rewinding shall be as under:- |
| 67 | (a) 300 mm sweep. |
| 68 | (b) 450 mm sweep. |
| 69 | (c) 600 mm sweep. |
| 70 | All as per item No 49 above but wall mounted fan / Air circulators of size 450 mm sweep. |
| 71 | All as per item No 49 above but wall mounted fan / Air circulators of size 600 mm sweep. |
| 72 | Supply and fix in repair ball bearing of any size suitable for ceiling fan 1200 mm / 1400 mm sweep complete all as specified and directed. |
| 73 | Supply and fix in repair shaft for leath work of any size suitable forceiling fan of 1200 mm / 1400 mm sweep complete all as specified and directed. |
| 74 | Supply and fix in repair gun metal bush of any size suitable for exhaust fan 300 / 450 mm sweep complete all as specified and directed. |
| 75 | Supply and fix in repair capacitor 4 MFD AC 230 Volt 50 HZ, of exhaust / bracket fan any size complete all as specified and directed. |
| 76 | Supply and fix in repair capacitor 3.15 MFD AC 230 Volt 50 HZ, of exhaust / bracket fan any size complete all as specified and directed. |
| 77 | Supply and fix in repair capacitor 5 MFD AC 230 Volt 50 HZ, of exhaust / bracket fan any size complete all as specified and directed. |
| 78 | Supply and fix in repair bolt, nuts, washer and split pin for the down rod of ceiling fan complete all as specified and directed. |
| 79 | Supply and connection in repair PVC insulated, PVC sheathed three core copper conductor cable multi stranded of size 0.5 Sqmm for connecting of fan from ceiling rose complete all as specified and directed. |
| 80 | Material and labourfor painting of ceiling fan including blades by scrapping of old paint, filling of cavities formed, preparation / cleaning of surface, making surface smooth and spray painting with one coat of white synthetic enameled paint of superior quality andwriting MES / SM No with appropriate size letters using black paint complete all as specified and directed. |
| 81 | Material and labour forpainting of exhaust fan including blades by scrapping of old paint ,filling of cavities formed, preparation / cleaning of surface, making surface smooth and spray painting with one coat of white synthetic enameled paint of superior quality andwriting MES /SM No with appropriate size letters usingblack paint complete all as specified and directed. |
| 82 | Assembling & fixing only ceiling fan of various sizes complete with blades, down rod canopy etc including hanging in position and connecting including taking down old fan complete all as specified and directed. |
| 83 | Assembling & fixing only exhaust fan of various sizes complete with blades, fixing with 4 nos hold fastener nut and bolt with washer and connecting with flexible PVC insulated multistranded copper conductor cable of size 0.75 sqmm from ceiling rose to exhaust fan including taking down old fan complete all as specified and directed. |
| 84 | Supply and fix of Fan clamp and rubber bush including nut , bolts, washers and split pin for hanging of ceiling fans complete all as specified and directed. |
| 85 | Supply and fixing ceiling fan MS clamp including nut, bolts and washers for various shapes and sizes for fixing of MS channel / pipe / angle complete all as specified and directed. |
| 86 | Supply and fix of fan rod of size 300mm long for ceiling fans complete all as specified and directed. |
| 87 | Supply and fix of fan rod of size 450mm long for ceiling fans complete all as specified and directed. |
| 88 | Supply and fix of fan rod of size 600mm long for ceiling fans complete all as specified and directed. |
| 89 | Supply and fix of fan rod of size 1050mm long for ceiling fans complete all as specified and directed. |
| 90 | Supply and fix Plastic louvers for exhaust fan along with connected accessories for 200 mm and 300 mm dia sweep exhaust fan complete all as specified and directed. |
| 91 | S&F in repair poly propylene plastic louver shutter (flap type) of size 350 mm x 350 mm, circulating opening 310 mm dia, fixed on wall for exhaust fan with screw complete all as specified and directed. |
| 92 | S&F for modular step type fan regulator 100 watt 2 module complete all as specified and directed. |
| 93 | Supply and fix of PCB Board for BlDC Ceiling Fan, 1200 mm sweep, 350 RPM, 32 watts suitable for make Hector 500,I-FALCON, complete all as specified and directed. |
| 94 | Supply and fix of Starter and Rotar with full assembly for BLDC ceiling Fan alongwith magnet ring, nut, bolt, washer etc suitable for make Hector 500, I-FALCON, complete all as specified and directed. |
| 95 | Supply and fix PVC body assembly for exhaust fan suitable for 200 / 250 / 300 mm complete all as specified and directed. |
| 96 | Supply and fix of exhaust fan motor suitable for 200 / 250 / 300mm PVC body complete all as specified and directed. |
| 97 | Supply and fixing fan blade for 1200/1400mm sweep ceiling fans suitable for existing fans complete all as specified and directed. |
| 98 | Supply and fixing fan blade for 300 / 380 / 450mm sweep exhaust fans suitable for existing make as per site complete all as specified and directed. |
| 99 | Supply and fixing iron Frame, Legs, rubber bush, nuts & bolts suitable for 300/380/450mm sweep exhaust fans for existing model as per site complete all as specified and directed. |
| 100 | M&L for MCB triple pole & neutral 415 volt C curve 10 KA, 63Amps capacity IP 20 complete all as specified and directed. |
| 101 | M & L for MCCB TPN 125A, 25KA,415 volts with thermal magnetic release adjustable type - overload Setting: 0.8-1.0 In- Short Circuit Setting: 6-10 In complete all as specified and directed. |
| 102 | M & L for MCCB TPN 160A, 25KA, 415 volts with thermal magnetic release adjustable type - overload setting: 0.8-1.0 In-Short Circuit Setting: 6-10 In complete all as specified and directed. |
| 103 | Supply and fix LED decorative post of lantern for 360degree indirect light with IP 65 protection, glare free and better uniformity light, cap 40 Watt fittings including all accessories fixing accessories fixed in position complete all as specified and directed. |
| 104 | S & F industrial type plug & socket board SP & N enclosure with 2 pole and earth metal plug & socket with 10 Amp MCB SP complete all as specified and directed. |
| 105 | S&F in repairs pole mounted junction box (Street light boxes) weatherproof cabinets IP-65-IK-09 class II with removable chasis and faceplates, lockable door handle, sealable cover, self extinguishing conforms to EN 60439-3, for single phase lighting system, suitable for 6 module with 1 row complete all as specified and directed. |
| 106 | S & F in repairs contactor 25A 2NO, suitable for 230V AC complete all as specified and directed. |
| 107 | S & F in repairs MCB DP 32A DX3 DP, suitable for 230V AC complete all as specified and directed. |
| 108 | Supply & fix in repair digital weekly timer switch of supply voltage 240vAC, 50/60 HZ complete all as specified and directed. |
| 109 | S & F in repair LED round spot light 3 W capacity, CCT :- 3000 K, working voltage level 220V-240V complete all as specified and directed. |
| 110 | S & F in repair LED round spot light 2 W capacity , CCT :- 3000 K, working voltage level 220V-240V, complete all as specified and directed. Make : Philips product code :- 919215850711 or equivalent makes as mentioned in Appx \"B\" to PS. |
| 111 | Supply and fix in repair pressure boosting system 1.0 HP cap, 220 Volt supply, suc & del pipe 25 x 25 mm size, complete all as specified and directed. |
| 112 | M&L for repairing / servicing the pressure pump set of capacity 0.5 to 1 HP by dismantling the pump and motor, over hauling of pump by replacing the complete worn out parts such as cast iron impeller, bearing, water seal, repairing the shaft by machining, welding, grinding, polishing etc, including servicing of electric motor suitable capacity with replacement of wornout bearing for driven and non driven ends, reassembling the pump and motor after servicing and repair and testing on load complete all as specified and directed. |
| 113 | M&L for dismantling of existing defective pressure pump motor of capacity 0.5 to 1 HP, single phase, 230 V, 50 Hz, from the foundation, disconnecting the electric connection, coupling pulley, cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding with super enamelled solid copper conductor (winding wire) of suitable gauge and size complete including varnishing, drying, ovening, overhauling, greasing and fixing in the same position, making necessary electric connection and testing of Pressure pump motor complete all as specified and directed.Note:-(i) For rectification of pumps and motors if any spares, Pressure switch, Pressure tank,sensor, non return valve, controller etc required to be replaced the same shall be measured and paid seperately under \"supply only\" items. |
| 114 | Supply only of Pressure Switch. |
| 115 | Supply only 24 Liter Hydro Pneumatic Pressure Tank / Pressure Pump Vessel / Pressure Pump & Booster Pump Tank suitable for brands pump |
| 116 | Supply only of Brass Non Return Valve 1\" |
| 117 | Supply only of Automatic Electronic Switch Control Water Pump Pressure controller |
| 118 | Supply only of 5 way tee brass. |