| Sl. No. | Item Description |
| 1 | Demolition of Brick work or stone / boulder masonry, built in cement mortar including allquoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articlescomplete all as specified and as directed. |
| 2 | Taking down cement plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed. |
| 3 | Demolition of reinforced cement concreteof any description and in any position not otherwise specifically provided for and removing the debris and rubbish to a distance not exceeding 100 m, complete all as specified and directed. (Note : reinforcement cut as required to facilitate demolitions) |
| 4 | Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness, (Below or above ground level) and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 m, complete all as specified and directed. |
| 5 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed. |
| 6 | Dismantling wrought iron or mild steel work of any description not otherwise provided for and removing from site of work complete all as specified and directed |
| 7 | Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, complete all as specified and directed. |
| 8 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed. |
| 9 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. |
| 10 | Taking down chowkats or frame, n.exc 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed. |
| 11 | Taking down chowkats or frame,exc 1.5 Sqmbut not exc 4.00 sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed. |
| 12 | Taking down shutter of any description exc 2 sq. m each and refixing in same opening complete all as specified and directed. |
| 13 | Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed. |
| 14 | Dismantling timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section , in any position complete all as specified and directed. |
| 15 | Taking up or down GI tubing of 15mm bore and connections, including cleaning for refixing or removal to store, complete all as specified and directed. |
| 16 | Taking up or down GI tubing of 20mm bore and connections, including cleaning for refixing or removal to store, complete all as specified and directed. |
| 17 | Dismantling of water tanks from roof /staggingetcand removing from site etc exc 250 but n.exc 500 Ltrs capacity, complete all as specified and directed. |
| 18 | Dismantling of water tanks from roof /staggingetc 3m and removing from site etc exc 500 but n.exc 1000 Ltrs capacity,complete all as specified and directed. |
| 19 | Dismantling boarding, any description, fixed in any position with screws complete all as specified and as directed. |
| 20 | M&L brickwork with sub class \"B\" bricks, straight or curved on plan exc6m mean radius built in cement mortar 1:6, complete all as specified and directed. |
| 21 | M & L for brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed |
| 22 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 23 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as inridges/valley gutters/roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 24 | M & L for powder coated aluminium snap grid frame work for false ceiling of suitable size panelwith hangers 4 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs/roof truss by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete as per manufacturer\"s instructions including fixing of nut, bolt and clamps with the help of drilling machinecomplete all as specified and as directed |
| 25 | M&L for non asbestos, Fibre cement reinforcedboard high pressure steam cured (Design-Oceanic or as approved), pre painted self finished white/ivory colour , 4mm thick size (595mm x 595 mm ) board fixed or laid /inserted toAluminium/G.I./M.S framework with screws if required allas per specification and drawing orallas per manufacturer\"s instructions complete all as specified and directed.(Note: Aluminium snap grid frame work shall be measured and paid separately) |
| 26 | M&L for rendering 15mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement, complete all as specified and directed. |
| 27 | M & L for rendering 15 mm thick in cement mortar (1:4) in two layers (10 mm thick in first layer and 5 mm thick in second layer) finished even and smooth (without using extra lime or cement) mixed with water proofing compound as per manufacturer’s instruction on top/secondlayer of plaster, complete all as specified and directed. (Note : WPC shall be measured & paid separately). |
| 28 | M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finishedfair and even, complete all as specified and directed. |
| 29 | M&L for rendering 5mm thick in cement mortar 1:3 on ceiling and soffits of staircase, waist slab or concrete surface finished even and smooth without using extra cement,complete all as specified and directed. |
| 30 | Supply only water proofing compound approved quality, complete all as specified and directed. |
| 31 | M & L for75mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base flooring including formwork, if required,complete all as specified and directed. |
| 32 | M & L for25mm thick PCC 1:2:4 type B-0 using 12.50mm graded stone aggregate as in levelling course to floor finishes complete all as specified and directed. |
| 33 | M&L for scratch free light shade vitrified tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 1.44 sqm, in floors etc. set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 15mm thick screed bed of cement mortar 1:6, complete all as specified and directed. |
| 34 | M&L for scratch free light shade vitrified tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 1.44 sqm, as in skirting, dado, riser to steps etc, set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and directed. |
| 35 | M&L forjoint free, coloured non skid ceramic tiles 7 to 8 mm thick (square /rectangular) area of each tile exceeding 0.18 Sqm but n.exc 0.38 Sqm, in floors etc, set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 15mm thick screed bed of cement mortar 1:6, complete all as specified and directed. |
| 36 | M&L forjoint free, coloured non skid ceramic tiles 7 to 8 mm thick (square /rectangular) area of each tile exceeding 0.18 Sqm but n.exc 0.38 Sqm, as in skirting, dado, riser to steps etc,etc, set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and directed. |
| 37 | M&L for Pre-polished kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab complete over and including 20mm thick screed bed of cement mortar 1:6, complete all as specified and directed. |
| 38 | M&L for Pre-polished kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed withwith grey cement slurry mixed with pigment to match the shade of the slab complete over and including 10mm thick rendering in cement mortar 1:3, complete all as specified and directed. |
| 39 | M&L forjoint free, coloured non skid ceramic tiles 7 to 8 mm thick (square /rectangular) area of each tile exceeding 0.11 Sqm but n.exc 0.18 Sqm, in floors etc, set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 15mm thick screed bed of cement mortar 1:6, complete all as specified and directed. |
| 40 | M&L for coloured glazed ceramic tiles of size 450x300x7mm to 8mm thick in vertical surface set and jointed in neat cement slurry pointed with white or coloured cement to match over and including 10mm thick rendering incement plaster 1:4, complete all as specified and directed. |
| 41 | M&L for 18-20mm thick Granite (of any type) tiles machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete as in floor, cooking platforms and like complete over and including 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed. |
| 42 | M&L forpre-polished, factory made, chequered cement concrete tilesof size 30cm x 30cm x 25mm thick, machine pressed, with grey cement andpigment, in floors etc, set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 20mm thick screed bed of cement mortar 1:6, complete all as specified and directed. |
| 43 | M & L for sand cushioning as in bedding for laying of tiles complete all as specified and as directed. |
| 44 | M & L for 60mm thick Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 , M-35 Grade, paver block coloured with grey cement and pigment laid over sand cushioning all as specified and directed.(Note : sand cushioning shall be measured and paid under respective item) |
| 45 | M & L for 100mm thick PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in sub base of floorcomplete all as specified and directed. |
| 46 | M & L for synthetic acrylic badminton court flooring with the following procedures:- (a)Synthetic Acrylic flooring (08 layers) includes (i) Fibre mesh with primer (ii) Filler course(iii) Heavy rubber Course (iv) Fine Rubber Course (v) Texture Course (vi) Finish course two layers(b) Line marking(c)removal of existing layers(of any type)from the floor and levelled by 40mm thick PCC sub base 1:2:4Type B-2 (using 20mm stone aggregate) including filling of expansion joints complete all as specified and as directed.(Note: Synthetic badminton court flooring shall be done with Authorised Manufacturers/dealer as approved by GE) |
| 47 | M & L for 75mm thick PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as inplinth protection laid inalternate baysnot exc 2 Sqm each andfinished the surface fair and even without using extra cement , providing joints though out the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand byweight complete all as specified and directed. |
| 48 | M & L for PCC (1:2:4) , type B-1 (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including formwork if required , complete all as specified and as directed |
| 49 | M & L for PCC (1:2:4) , type B-0 (using 12.5 mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including formwork if required , complete all as specified and as directed |
| 50 | M & L for PCC (1:3:6) , type B-1 (using 20 mm graded crushed stone aggregate) in in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including formwork if required , complete all as specified and as directed |
| 51 | M & L for separating, scraping and cleaning of reinforecement complete all as specified and as directed. (Note : Demolition of concrete shall be measured and paid under respective item) |
| 52 | M&L for RCC M-25 (Design Mix) (using 20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.(Note : Reinforcement and form work will be measured and paid separately under relevant items) |
| 53 | M&L RCC M-25 (Design Mix) (using 20mm graded crushed stone aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary formworkcomplete all as specified and directed. (Note : Reinforcement and form work will be measured and paid separately under relevant items) |
| 54 | M&L for RCC M-25 (Design Mix) (using 20mm graded crushed stone aggregate) as in columns,pillars, piers, posts and strutscomplete all as specified and as directed. (Note : Reinforcement and form work will be measured and paid separately under relevant items) |
| 55 | M&L for RCC M-25 (Design Mix) (using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m spancomplete all as specified and as directed. (Note : Reinforcement and form work will be measured and paid separately under relevant items) |
| 56 | M & L for steel form work to side of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work,vertical or to batterfor rough finished surface of concrete in flat complete all as specified and directed. |
| 57 | M & L for steel form work tosoffits of suspended slab not exceeding 200mm thick for rough finished surfaces of concrete flat complete all as specified and as directed. |
| 58 | M & L for steel form work to curved soffits of suspended slab not exceeding 200mm thick for rough finished surfaces of concretecomplete all as specified and as directed. |
| 59 | M & L for steel form work tosquare, rectangular or polygonal/circular on plan to side of concrete pillars, posts, struts, piers,columns and stanchion for rough finished surfaces complete all as specified and as directed. |
| 60 | M & L for steel form work tosides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc for rough finished surfaces complete all as specified and as directed. |
| 61 | M & L for steel form work toedges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 5cm but n exc10cm wide for rough finished surfaces of concrete flat complete all as specified and as directed. |
| 62 | S & F TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. |
| 63 | S & F TMT steel bars6 to 8 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. |
| 64 | S & F TMT steel bars5mm dia and over upto & incl 10mm dia in stirrups, spacers and binders, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. |
| 65 | S & F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161- 1979 grade St.-240 complete all as specified and as directed. |
| 66 | S & F rolled mild steel in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of grade Fe 410 -W (Gde- E- 250) quality- Acomplete all as specified and as directed. |
| 67 | S & F1.25mm thick ,pressed steel frames of size 105 x 60mm size for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified and directed. |
| 68 | S & F1.25mm thick ,pressed steel frames of size 125 x 60mm size for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified and directed. |
| 69 | S & F well seasoned 2nd class hard wood in scantling wrought on sides framed complete all as specified and as directed. |
| 70 | S & F for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet reinforced with M.S. Square tube, all as per specification & drawing completeand as directed. |
| 71 | S & F 35 mm thick, 2nd class hardwood, factory made, Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 72 | S & F 35 mm thick, factory made, Second class hardwood, glazed and skeleton shutters open rebated and prepared to receive glass, gauge, etc, divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded, etc complete all as specified and directed in SSR Part I Section 8 clause 8.24 (a). |
| 73 | S & F Factory Made Solid PVC Moulded Door Shutter, with wood free EPS,28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing, complete all as directed. |
| 74 | S & FFactory made PVC 18-19mm thick decorative lamination board of density 600 kg/cbm manufactured by an ISO:9001-2005 certified with termite proof, water proof and flame retardant PVC sheet complete fixed with each other using solvent cement adhesive and stainless steel screws etc,panels shall be fabricated using adhesive and screws , all the edges shall be covered with bonding tape and finished, supplying & fixing in the frame at site as per specification & drawing, complete all as directed. |
| 75 | S & F25mm thick block boards, grade 2 quality, interior grade, decorative type with decorative face veneer one face, fixed with screws to timber or steel frame workcomplete all as specified and as directed. |
| 76 | S & F18 to 19mm thick block boards, grade 2 quality, interior grade, decorative type with decorative face veneer one face, fixed with screws to timberframe work as in shelves, drawers etc complete all as specified and as directed. |
| 77 | M & L for Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P. brass/ stainless steel screws, all complete as specified and directed. |
| 78 | M & L for powder coated aluminium door shutters,aluminium section weighing 0.55 kg/m (minimum thickness of powder coating 50 micron)including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. powder coating of any colour complete all as specified and directed. |
| 79 | S&F 25mm thickPowder coatedAluminium Sliding window shutter(minimum thickness of powder coating 50 micron) three way track section for frames of weight not less then 1.17 kg/RM and sliding section for shutter frameall round with aluminium section of weight not less then 0.42 kg /RMin two panels and shutter including necessary aluminium fittings with and including 5 mm thick selected quality plain glass and third oneand including stainless steel wire cloth mesh of 0.36mm nominal dia of wire and average width of aperture 1.40mm as approved by GE fixed with stranded aluminium channel out side with andincluding handle, cleat,glazing clip ,special auto lock,dry set ,rubber gasket complete all as specified and as directed. (Note:The quoted rateshall be inclusive ofsheet glass,stainless steel wire cloth mesh, ) |
| 80 | M & L for powder coated (minimum thickness of powder coating 50 micron) aluminium window and ventilator shutters side hungtype without sash bars, aluminium sections weighing 0.55 Kg/m including necessary jointing cleats, glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges type B-21 , 100mm long (02 Nos per shutters) suitable handle 01 No per shutteretc. powder coating of any colour complete all as specified and directed. |
| 81 | S & F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, conforming to Fe 290Gde E-165 quality B complete all as specified and as directed. |
| 82 | S&F fabricated powder coated anodized aluminium grill of size 75 x 75mm, using 6mm dia bars fixed to outer portion of chowkhat using U/V section runners complete all as specified and as directed. |
| 83 | M & L \"in repair\" for 9 mm thick, weather proof Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to aluminium frame work complete all as specified and directed. |
| 84 | M & L formild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 85 | M & L plates (plain or chequered)square cut or notched (Ordinary and counter sunk) forming holes, without any attachmentconforming to Fe 410 W Gde E-250 quality A complete all as specified and as directed. |
| 86 | S&F 5mm thick Sheet glass, ordinary quality and glazing in aluminium section in square exc 0.5 sq. m in each pane complete all as specified and directed. |
| 87 | S & Ffor 4 mm thick,figured sheet glass, pin head type and glazing with oil puttyor wooden beading in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed. |
| 88 | S & FStainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed. |
| 89 | S & F 100mm size, Butt hinges, stainless steel complete all as specified and directed. |
| 90 | S & F 100mm size, Butt hinges,medium weight cold rolled mild steel and fixed complete all as specified and directed. |
| 91 | S & F 150 mm size, Aluminium alloy handles,fabricated type, anodised complete all as specified and directed. |
| 92 | S & F 125 mm size, Aluminium alloy handles,fabricated type, anodised complete all as specified and directed. |
| 93 | S & F 100 mm size, Aluminium alloy handles,fabricated type, anodised complete all as specified and directed. |
| 94 | S & F 150 mm long, Aluminium anodised, barrel tower bolts of extruded section fixed,complete all as specified and directed. |
| 95 | S & F 200 mm long, Aluminium anodised, barrel tower bolts of extruded section fixed,complete all as specified and directed. |
| 96 | S & F 300 mm long, Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed,complete all as specified and directed. |
| 97 | S & Ffor Double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heady duly and fixed complete, all as specified and directed. |
| 98 | S & F \" in repairs\" 300mm long mild steel ordinary rat tail rod pattern springs including roller and roller plate complete, all as specified and directed. |
| 99 | S & F for 75mm size hasp and staple, safety type, aluminium anodisedwith mild steel hinge pin including bolt to hinge plate and fixed with screws,complete all as specified and directed. |
| 100 | S&F \" in repair\" 25 mm dia curtain rod medium weight pipe made out of stainless steel 304 grade,decorative type complete all as specified and as directed. |
| 101 | S&F decorative type brackets with ends/stops etcincluding other accessoriesfor fixingarrangements of25 mm dia curtain rodto wall ,complete all as specified and as directed. |
| 102 | M & L for Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed. |
| 103 | M & L for preparation of newor previously untreated steelor iron surfaces of any description over 10cm width or girthand applying two coats of synthetic enamel paint over a coat of red oxideprimer complete all as specified and directed. |
| 104 | M & L forpreparation of old plastered surfaces of wall and applying two coats ofoil distemper emulsion (Ist quality) of approved manufacturerover a coat of primer paint, over and including 1.5mm thick acrylic wall care putty , after complete removal of existing treatment from walls, complete all as specified and directed. |
| 105 | M & L for preparation of new plastered surfaces of wall and applying two coats of oil distemper emulsion(Ist quality) of approved manufacturer over a coat of priming paintover and including 1.5mm thick wall care puttycomplete all as specified and directed |
| 106 | M & L forpreparation ofnewly plastered surfaces of wall and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UVresistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed. |
| 107 | M & L forpreparation ofnewly plastered surfaces of ceilingand applying three coats ofwhite wash,complete all as specified and directed. |
| 108 | M & L forpreparation ofold plastered surfaces of ceiling and applying two coats ofwhite wash,complete all as specified and directed. |
| 109 | M & L forcomplete removal of existing treatment of surfaces of wall and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UVresistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces, complete all as specified and directed. |
| 110 | M & L for preparation of newplastered or previously untreated surfaces of any description, not otherwise described and applying two coats of plastic emulsion plaint (1st grade quality) over a coat ofpriming paint complete all as specified and directed. |
| 111 | M & L for Preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying onecoat of synthetic enamel paint (1st grade quality)complete all as specified and directed. |
| 112 | M & L for Preparation of wood and wood based surfaces new or old surfaces of any description, not otherwise described, and treated with creosote oil complete all as specified and directed. |
| 113 | M & L for Preparation of old painted steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying onecoat of synthetic enamel paint (1st grade quality)complete all as specified and directed. |
| 114 | Writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high with synthetic enamel paint, complete all as specified and directed. |
| 115 | Taking down/out of existing roof treatment including brick tile or terrazo tile of any thickness from RCCroof bydismantling tiles/scrapping/scrubbing/brooming, sweeping clean and washing down with water using wire brush brooming downand removing debries/rubbish materials outside MOD land complete all as specified and as directed. |
| 116 | M & L for25mm thick PCC ( 1:2:4) type B-0 (12.50mm graded aggregate) as in roof padding, wherever required, finishing cement concrete surface even and smooth without using extra cement, complete all as specified and directed. |
| 117 | M&L for rendering 15mm thickin cement mortar 1:4mixed with water proofing compound onon existing roof surface true to level ,finishedfair and smooth, complete all as specified and directed.(Note: WPC shall be measured and paid separately) |
| 118 | M & L for RCC roof treatment all as directed in order of precedence as stated after plaster /padding work :-(i) Applying evenly a priming/tack coat with hot blown bitumen 85/25 at the rate of 1.20 kg per sqm.(ii) Supply and laying 3mm thick APP based polymeric membrane of approved manufactured with weight not less than 3.60 Kgs per Sqm reinforced with non-woven polyester fabric/matt weighing not less than 160gms per Sqm having softening point not less than 150 mm centigrade, having tensile strength of 650 N/5cm and 350 N/5cm in longitudinal and transverse directions respectively of the reinfocred tearing strength of 180 N by torch application . Polymeric membrane shall be taken to a height of 30cm(minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing wherever it is noticed.(iii) Applying one coat of aluminium paint over APP membraneNote :- (i)Laying APP based polymeric membrane shall be done torch on method as per manufactures instructions. (ii) A minimum overlap of 100mm and 75mm should be made at the endand sides of the polymeric membrane respectively and sealed alloverlaps and joints as per manufacturers instruction.iii) APP based polymeric membrane shall beof any one of the approved makes as specified here-in-after and shall conform to specifications given in IS 16540-2017/IS 16532-2017. |
| 119 | Item No 118 Contd..... (iv)Contractor shallproduce necessary test certificate of the manufacturer to the Engr-in-Chage before incorporation in the work. (v)Necessary independent tests shall also be carried out by the Contractor without any extra cost to the Deptt as per relevant IS specifications and membranes with satisfactory test results shall only be incorporated in the work(vi)The work shall be executed through authorised applicators of original manufacturer only |
| 120 | S & F500 litres capacityrotational moulded polyethylene (HDPE) water storage tanks (Cylindrical vertical with closed top), ISI Marked, conforming to IS 12701-1989having triple layers wall construction with manhole threaded lid and suitable locking arrangement including making holes for inlet, outlet and over flow pipes,hoisted and fixed in position complete allas specifiedand directed. |
| 121 | S & F 1000 litres capacityrotational moulded polyethylene (HDPE) water storage tanks (Cylindrical vertical with closed top), ISI Marked, conforming to IS 12701-1989havingtriple layers wall construction with manhole threaded lid and suitable locking arrangement including making holes for inlet, outlet and over flow pipes,hoisted and fixed in position complete allas specifiedand directed. |
| 122 | S&F 20mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm- 42gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) complete all as specified and directed. |
| 123 | S&F \" in repair\" 20mm bore diagun-metal. Globe or gate valveswith iron wheel head screwed both ends for iron pipes complete all as specified and directed. |
| 124 | S&F 15mm bore UPVC pipes of pressure rating 10 Kgf/sqcm with all fitting and fixed complete to walIs and ceilings or laid in floors complete all as specified and directed. |
| 125 | S&F 20mm bore UPVC pipes of pressure rating 10 Kgf/sqcm with all fitting and fixed complete to walIs and ceilings or laid in floors complete all as specified and directed. |
| 126 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubingetc., and making good, cutting not exc 10 cm girthin brick walls,complete all as specified and directed. |
| 127 | S&F \" in repairs\" 15mm borefancy type chromium plated, concealed stop valves ,cast copper alloy,screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 128 | S&F \"in repair\"15mm bore fancy type chromium plated angular stop cock , screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 129 | S&F \"in repairs \"for15mm bore , fancy type chromium plated bib tap, cast copper alloy with capstan head long body and cup, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 130 | S&F \"in repair\"15mm bore fancy type chromium plated, two way bib cock with flange , screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 131 | S&F \"in repair\"15mm bore fancy type chromium plated, two way angular stop cock , screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 132 | S & F \" in repairs \" 15mm bore, PVC connection pipe 450mm long with PTMT nuts at both ends complete all as specified and directed. |
| 133 | S & F \"in repair\"32 mm diaWaste fittings, brass, chromium plated for glazed ware sinks, basins,etc. with long screwed shanks and fly-nuts, flange end beddedinred leadcement and other end fixedcomplete all as specified and directed. |
| 134 | S&F \"in repairs \" pillar taps,15mm bore, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed fancy type complete all as specified and directed. |
| 135 | S&F \"in repair\" 3 in-1 brass chromium plated fancy typewallmixer, 15mm bore including provision for hand shower and overhead shower with 115mm long bend pipe for mixing hot & cold water screwed down for iron pipe and fixedcomplete all as specified and directed. ( Note:- Hand and overhead shower shall be measured and paid separately) |
| 136 | S&F \"in repair\"brass chromium plated fancy type centre hole mixer, 15mm bore table mounted J type \"for mixing hot & cold water screwed down for iron pipe and fixedcomplete all as specified and directed. |
| 137 | S&F \" in repairs\"20mm dia, 600mm long of chromium plated tubular Towel Rail, \"D\" Type fixed with and including Chromium plated brass screws and wooden/plastic cleatscomplete all as specified and directed. |
| 138 | S&F \"in repairs\"8mm dia chromium plated tubular Towel Towel Ring square with round flange , fixed with and including Chromium plated brass screws and wooden/plastic cleatscomplete all as specified and directed. |
| 139 | S&F \"in repair \" 15mm bore CP health faucetalong with 1m long flexible tube and holding stand incl all necessary fitting complete all as specifiedand as directed |
| 140 | S&F \" in repair\"15mm bore 125mm size chromium plated shower roses with arm ,with or without swivel joints, any size, including fixing to steel pipe or union, complete, all as specified and as directed. |
| 141 | S&F \" in repair\"15mm bore 180mm size chromium plated shower roses with shower arm of 225mm long,with or without swivel joints, any size, including fixing to steel pipe or union, complete, all as specified and as directed. |
| 142 | S&F \" in repair \"chromium plated brass soap dish , any type , fixed to plugs with chromium plated brass screws, complete all as specified and as directed. |
| 143 | S&F \" in repair \"chromium plated brass toilet paper holder with cover plate, box type fixed to walls with chromium plated (CP) brass screws, complete all as specified and as directed. |
| 144 | S & F\"in repairs \"10 litre capacity, PVC valve less syphonic action type, flushing cistern, low level, white,with inlet, ball valve, float and handle including brackets complete all as specified and directed. |
| 145 | S & F\" in repair \" 600mmX450mm bevelled edge mirror of 5mm thick, selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plug with chromiun plated brass screws and cup washers complete all as specified and directed. |
| 146 | S & F\" in repair \" 6mm thick looking mirror of selected quality glass mounted, edges shall be mouldedproperly and fixed to wall with chromiun plated brass screws and cup washers complete all as specified and directed. |
| 147 | S & F\" in repair \" PVC cabinet Mirror with b uilt in shelf and looking mirror of size 480 x 380 x 200mm and fixed to wall with chromiun plated brass screws and cup washers complete all as specified and directed. |
| 148 | S&F \" in repair \"Corner glass shelf fancy type assembly consisting of 5.5mm thick sheet glass with stainless steel railing fixed to wall with rawl plugs and chromium plated screws complete all asspecified and as directed. |
| 149 | S & F \" in repairs\" Vitreous China table top wash basin, white,oval type , size 425 x 340 x 175mm excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and directed. |
| 150 | S & F \" in repairs \" vitreous China wash down water closet pan (pedestal pattern), white, \" P \" or\"S \" trap ,including connection to outgoing drain andflushing pipe, anti syphonic pipe withand including water closet seat cover complete but excluding flushing cistern & flush pipe including making good damaged/disturbed surfaces complete all as specified and directed. |
| 151 | S & F \" in repairs \" Flush pipe of polyethylene of low or high density or PVC 32 mm dia, for low level cistern complete all as specified and directed |
| 152 | S & F \" in repairs \" 15mm bore Maze Hand showerof head 95mm dia round shape, single flow (Face plate stainless steel and ABS body in chrome finish) with rubit cleaning system,complete all as specified and directed |
| 153 | S & F \" in repairs\" Vitreous ChinaHalf stall urinal, white, flat back, size 600 x 395 x 365mmwith grating and union for discharge pipe (excluding flushing cistern, flush pipe and wate pipe) but inculding connection to flushing pipe and outgoing pipes complete all as specified and directed. |
| 154 | S & F Urinal spreader of PTMT of any colour for fixing with 15mm dia pipe (Minimum weight 60 gms) complete all as specified and directed. |
| 155 | S & F \" in repairs\" rubber door cill guard/snake guard with 25mm wide aluminium strip fixed at bottom of door to prevent from snake/insects completeall as specified and directed. |
| 156 | S & F Partition glass 6mm thick heat strengthen glass with both sides acid frost finish size 450 x 900mm cut and finish and fixed on wall using SS 304 Heavy L bracketcomplete all as specified and directed. |
| 157 | S & F \" in repairs\" vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe), with \" P\" or \"S\" trap\" , including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor, complete all as specified and directed. |
| 158 | S & F \" in repairs\"sliding wall to wallshower enclosure with one fixed glass and one sliding door(Two part glass ) 8mm thick chrome finish of size1.50 to 2.00 mtr width and 2.00 mtr height, right/left side version, moving/sliding arragement etc if requiredcomplete all as specified and directed. |
| 159 | Taking down eaves gutters and rain water pipes(any size or pattern) including all fittings, heads, shoes, bends, swan necks etc including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) ,complete all as specified and as directed. |
| 160 | S&F110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with stack clamps ,complete all as specified and as directed. |
| 161 | S&F110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints , laid in trenches or in floors,complete all as specified and as directed. |
| 162 | S&F75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with stack clamps,complete all as specified and as directed. |
| 163 | S&F75mm bore PVC (SWR) pipes single socketed in any length with rubber ring jointslaid in trenches or in floors, complete all as specified and as directed. |
| 164 | S&F 110mm bore, PVC (SWR) bends of any radious , complete all as specified and as directed. |
| 165 | S&F 75mm bore, PVC (SWR) bends of any radious , complete all as specified and as directed. |
| 166 | S&F 75mm bore, PVC (SWR) junction, single (single T) equal or unequal, complete all as specified and as directed. |
| 167 | S&F 110mm bore, PVC (SWR)junction, single (single T) equal or unequal, complete all as specified and as directed. |
| 168 | S&F \"in repair\" 75mm dia, PVC (SWR) floor trap, plain with stainless steel square grating 100 x 100mmincluding jointing with solvent cement to wast pipe fixed in cement concrete type B-1 (1:2:4)complete all as specified and as directed. |
| 169 | S & F 110mm bore PVC (SWR) vent cowl, complete all as specified and as directed. |
| 170 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for lying of cable etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soilcomplete all as specified and directed. |
| 171 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in soft/loose soilcomplete all as specified and directed. |
| 172 | M & L for PCC ( 1:2:4 ),type B-2 (using 40 mm graded crushed stone aggregate) in foundations, filling and mass concrete etc, including formwork, if required, complete all as specified and as directed |
| 173 | M & L for PCC ( 1:4:8 ),type D-2 (using 40 mm graded crushed stone aggregate) in foundations, filling and mass concrete etc, including formwork, if required, complete all as specified and as directed |
| 174 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and as directed. |
| 175 | Removing excavated material(Soils) to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting pointcomplete all as specified and as directed |
| 176 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 177 | Taking down fan any type , sealing cable end, dismantling blades and removing fan and blades deposited to MES store yard complete all as directed |
| 178 | Taking down unserviceable/BER geyser of any capacity from existing location /site and depositing MES store yard complete all as directed |
| 179 | M & L for point wiring for One light point / one fan point controlled by one, one way swtich complete as specified with 1100 V grade with 1.5 Sqmm single core PVC insulated unsheathed FR-LSH cable, copper conductor multistranded passing through including PVC conduit(medium grade) concealed on wall/floor and surface type on ceiling of size not less than 20mm dia with concealed modular box suiltable for logic modular switches, sockets, etc and logic modular white plates, sourroundings of suiltable size as required at site with PVC insulaterd FRLSH unsheathed stranded copper conductorof size 1.5 sqnn as earth wire connectedto common earth dolly as specified complete all as specified and directed for the following :- Note :-(i) Rate quoted shall include for cost of making concealed MS box in stone/brick wall including cutting and sinking of boxes and making good to the stone/brick walls (No extra payment will be made for the same.(ii) Provision of blank plates as per site requirement (No extra payment will be made for the same) |
| 180 | All as per Srl item No. 179 here in before butfor One 5 Amp 5 pin socket outlet point on same board complete. |
| 181 | All as per Srl item No. 179here in before but on independent board complete. |
| 182 | All as per Srl item No. 179here in before but one light point controlled by 2 way switches complete. |
| 183 | All as per Srl item No. 179 herein before but with 4.0 SqmmPVC copper stranded cable FRLSH type for one 15 Amp 6 pin socket outlet point including PVC cable 4.0 Sqmm FRLSH type copper stranded conductor as earth wire as specified & connected to commen earth & earth terminals including boards for mounting purposes complete. |
| 184 | All as per Srl item No. 179 here in before but one bell/buzzer point controlled by one push button on the same board with other switches or independent complete. |
| 185 | S & F in replacement Switch modular type, single pole, one way, 6 Amp, one module, IS:3854 marked with valid CML No complete all as specified and directed. |
| 186 | S & F modular Switch socket combination 16 A, 6 Pin, 3 module, 230V, AC white finish complete all as specified and as directed. |
| 187 | S & F Switch piano flush type 5/6 Amps single pole one way, 230 volts AC including connection complete all as specified and as directed. |
| 188 | S & F socket outlet 2 in 1, multipurpose, suitable for 5 pin, 5/ 6 Amp flush typeincluding connection complete all as specified and as directed. |
| 189 | S & F Switch socket combination, 2 in 1, multipurpose, suitable for 5 pin, 5/ 6 Amp flush typeincluding connection complete all as specified and as directed. |
| 190 | S & F Switch socket combination, 2 in 1, multipurpose, suitable for 6 pin, 5/ 6 Amp and 15/ 16 Amp flush type including connection complete all as specified and as directed. |
| 191 | S & F bell push,modular type, single pole, , 10 Amp, one way, one module,IS:3854 marked with valid CML Nocomplete all as specified and directed. |
| 192 | S & F Switch piano flush type 6 Amps single pole two way, 230 volts AC including connection complete all as specified and as directed. |
| 193 | S & F in replacement of bell, ding dong type AC, 230 volts, single phase complete all as specified and directed. |
| 194 | S & F copper wound ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE.Energy efficient, five star rated, with brushless direct current motor (BLDC) complete with mounting arrangment as per site requirementand connecting wire up to nearest ceiling rose in flexible PVC pipe complete all as specified and directed. |
| 195 | S & F copper wound exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete with mounting arrangment as per site requirementand connecting wire up to nearest ceiling rose in flexible PVC pipe complete all as specified and directed. |
| 196 | S & F stepped fan regulator modular type, two module, IS:3854 marked with valid CML Nocomplete all as specified and directed. |
| 197 | S&F ceiling rose of size 65 x 50 mm surface bakelite 240 Voltsthree terminal complete all as specified and directed. |
| 198 | S & F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose up to 1.5Mtr length complete all as specified and directed. |
| 199 | S & F LED lights fitting mirror type with high out put diffuser 2 feet, 10W,220V, AC decorative box type with driver holder andLED lamp includingconnecting up with three core flexible copper conductor cable of suitable size from ceiling rose up to 1.5Mtr length complete all as specified and directed. |
| 200 | S & Fround shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose up to 1.5Mtr length complete all as specified and directed. |
| 201 | S&F electric water heater storage type steel body with copper inner tank and heating element upto 1.5/2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, includingPVC connectionpipe for hot/ cold water to existing water lines,necessary fixing arrangementby using 50 X 5 mm MS plateand writing MES No and paste the instruction sheet of Do’s and DO NOTcomplete all as specified and as directed. |
| 202 | S & FLED street light fitting 35/36 Watt, 230 V, AC outdoor type, IP-65/66, with high pressure die cast aluminum hasing and heat resistant complete with in-built driver inside the housing, lamp bracket with impactand corrosion resistant including thermal management in multiple optics completeall as specified and as directed. |
| 203 | S&F in repalcement of recessed mounted 36 watt (clear white) LED panel light 2 x 2 feet ultra slim design of CRCA sheet housing pre-coated white colour and high quality diffuser for uniform light and high efficiency with electronic drivercomplete all as specified and as directed. |
| 204 | S & F for factory made sheet metalenclosure, concealed, double door SPN, 230 V, 4 Way DB, IP 42 with 200 Amps rated busbar, recessed/flushed in wall complete with copper bus bar, neutral link, dinrail suitable for mountaning MCB’scomplete all as specified and as directed. |
| 205 | S & F factory made sheet metalenclosure, concealed double door designed SPN, 230 V, 8 Way DB, IP 42 with 200 Amps rated copper busbar, grouter/ fixed flush in wall with and including suitable flat iron complete with separate link for neutral, dinrail suitable for mountaning MCB’scomplete all as specified and as directed. |
| 206 | S & Fin repair MCB SP 6 to 32 Amp , 10 KA breaking capacity, B Curve,230 Volt etc complete with connection testing and commissioning complete all as specified and as directed. |
| 207 | S & F in repair MCB SPN 32 Amp with 10KAbreaking capacity, B curve, 230 Volt complete all as specified and as directed. |
| 208 | S&F Metal plug and socket assembly, Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amp \"C\" curve fixed flush to wall complete all as specified and directed |
| 209 | S & F sheet metal enclosure (Factory Made) VTPN DB-VTPN 415 volts 4 way , IP 43 protection with MCCB\"s 160A as incomer, double door , 4 way No of modules I/C XTI 160, O/G 12 Nos with 250 Amps rated copper bus bar complete all as specified and directed. |
| 210 | M & L for sub main wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLSH type, cables 6 Sqmm drawn through in and including rigid PVC heavy duty concealed conduits including 6 Sqmm 1100 Volts grade, FRLSH type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminalsincluding taking down of old wiringcomplete all as specified and directed.Note:- (i)Threeruns of cables in conduit will be measured as one length of sub main. (ii)PVC conduit and its accessories is deemed to be included in this item rates.(iii) Unit rate include for cutting chases for conduits and sinking for boxes andmaking good to wall, floors etc. |
| 211 | M & L for sub main wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLSH type, cables 10.0Sqmm drawn through in and including rigid PVC heavy duty concealed conduits including 10.0 Sqmm 1100 Volts grade, FRLSH type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals including taking down of old wiring complete all as specified and directed.Note:- (i)Threeruns of cables in conduit will be measured as one length of sub main. (ii)PVC conduit and its accessories is deem to be included in this item rates.(iii) Unit rate include for cutting chases for conduits and sinking for boxes andmaking good to wall, floors etc. |
| 212 | Material & Labour in replacement of Earthing complete withgalvanised steel earth plate electrode 60cmx60cmx6 mm thickness burried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to and incl galvanised earth lead wire of 4.00mm dia by means of nuts & bolts, check nuts and washers of galvanised incl PCC pit of 1:2:4 type B-1, cover reinforced with XPMweightnot less than 4 Kg/Sqm and 6mm dia bar handle, earth pit angle iron frame of size 25mm x 25mm,excavation and earth work in anytype of soil, charcoal dust, salt, light grade GI watering pipe 20mm dia with funnel and wire mesh and medium grade GI protection pipe of 15mm bore from top edge of earth plate upto main distribution board complete allto as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected main switch board all as specified and testing on completion, including disposal of surplus soil to a distance not exceeding 50m , complete all as specified and as directed.[Note : (a)The unit rate includes for protection pipe and earth lead upto 7.5 m. Any variation in length of earth leas and protection pipe beyond 7.5 m shall be measured and paid seperately.(b)Excavation/earthwork is deemed to be included in the quoted rate.] |
| 213 | Supply, Installation, Testing and Commissioning of SOLAR Water system (Evacuated Collector) based on direct transfering of heat of capacity 1000 LPD complete all as specified and as directed. |
| 214 | Supply and laying 25mm outer dia ,3- layer PP-R Polypropylene random copo- lymer) conceal- ed pipes SDR 7.4 (PN16) UV stabi- lized and antimi- crobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches/wall/ceilings/ floors complete including fittings all as specifed and as directed. |
| 215 | Supply and laying40mm outer dia ,3- layer PP-R Polypropylene random copo- lymer) conceal- ed pipes SDR 7.4 (PN16) UV stabi- lized and antimi- crobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches/wall/ceilings/ floors complete including fittings all as specifed and as directed. |
| 216 | S & F in replacement of socket, 6A-2/3 pin combined 2 module, multipurpose230 volts, single pole, one way suitable for 3 pin/2 pin, 5 amp plug top white finish complete all as specified and as directed. |
| 217 | S & F in replacement of stepped type electronic fan regulator socket type on the existing phenolic laminated sheet etc as required complete all as specified and as directed. |
| 218 | Sch \"A\" Part-II (SCHEDULE OF CREDIT)Note :- Amount of Rs.11,22,568.00 indicated in Tender Documents as Schedule of Credit shall be deducted from the total quoted amount of BOQ. |