| Sl. No. | Item Description |
| 1 | Demolition of brick workbuilt in cement mortar includingall quoins, arches , pillars etc but excluding precast concrete articles complete all as specified and directed by the Engineer-in-Charge. |
| 2 | M & L, Brick work with sub class \"B\" bricks, straight or curved on plannotexc 6 m mean radius built in cement mortar 1:6 complete all as specified anddirected by Engineer-in-Charge. |
| 3 | Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing ),and removing rubbish off the premises complete all as specified and directed by Engineer-in-Charge |
| 4 | M&L, First qualityglazed ceramic colouredtiles of(450x300mm) x 7mm thick, laid on vertical surfaces such as skirting, dados and risers to steps etc laid over and including10mm thick cement plaster in CM (1:4) set and jointed in neat cement paste ofhoney like consistancy and pointed in white or coloured cement to match the shadeof tiles complete all as specified and directed by the Engineer-in-Charge. |
| 5 | M&L, First quality, Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sq.m but not exceeding 0.11 Sq.m, laid in floors with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:6) including pointing in white cement with pigment to match the shade of tiles complete all as specified and directed by the Engineer-in-Charge. |
| 6 | Taking down cement plaster on brick walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, including removal of rubbish outside MoD landcomplete all as specified and directed by the Engineer-in-Charge. |
| 7 | M&L for Rendering 12 mm thick cement plaster in cement mortar (1:6) on fair faces of brick works or concrete surfaces , finished even and smoothwithout using extra cementcomplete all as specified and directed by the Engineer-in-Charge. |
| 8 | M&L for Rendering 5 mm thick on RCC ceiling surfaces in cement mortar 1:3 and finished even and smooth without using extra cementcomplete all as specified anddirected by Engineer-in-Charge. |
| 9 | M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 mixed with water proofing compound @ 3 % by weight of cement, , finished even and smooth without using extra cement complete all as specified. Note - WPC shall be measured & paid separately. |
| 10 | M&L forPreparation of new plastered wall surfaces and applying two coats of cement base paint complete all as specified and directed by the Engineer-in-Charge. |
| 11 | M&L for Preparation of new plastered or un plastered wall surfaces of any description and applying two coats of oil bound distemper over a coat of Chalk whitening complete all as specified and directed by the Engineer-in-Charge |
| 12 | M&L for Preparation of new plastered surfaces of ceiling,chajja etc, including brooming down or steel wire brushing; scrapping downsmoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc. and applying three coats of white wash complete all as specified and directed by the Engineer-in-Charge. |
| 13 | Demolition of cement concrete (unreinforced) in ground floors and paving not exc. 15 cm thickness (below or above ground level), including removal of rubbish outside MoD land complete all as specified and directed by the Engineer-in-Charge. |
| 14 | M&L for Plain cement concrete type B-1(1:2:4) using 20 mm graded stone aggregates as bed block ,coping , cills, steps etccomplete all as specified and directed by Engineer-in-Charge. |
| 15 | Taking up or down 15 mm bore steel tubing with connections or fittings from wall, ceiling and floor etc., including cutting/chasing in wall/floor and removal from site complete all as specified and directed by the Engineer-in-Charge. |
| 16 | S&F 20 mm bore ,CPVCmedium grade , with all fittings(like Elbow , Tee, Socket, Gi pipe connecter, nipples, tank adaptor etc) and fixed complete to walls and ceilings or laid in floors or concealed complete all as specified and directed by the Engineer-in-Charge. |
| 17 | Taking down chowkhats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each with shutter (without taking off shutters from the chowkhats) complete all as specified and directed by Engineer-in-charge. |
| 18 | Taking down shutters of any description exceeding 1 Sq. m but not exceeding 2 Sq. m each, from chowkhat complete all as specified and directed by the Engineer-in-Charge. |
| 19 | S&F, Factory made, 30 mm thick, Flush shutters, solid core construction, with block board core and plywood face panels, commertial type on both sides, fitted to chowkhats of 2nd class hard wood (hollock) complete all as specified and directed by the Engineer-in-Charge. |
| 20 | M&L for factory made 35 mm thick 2nd class hardwood (Hollock) skeleton shutters, open rebated and prepared to receive wire cloth, glass etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, wire cloth etc., sizes of members of shutters as specified in SSR Part-I section 8 clause 8.24(a) complete all as specified and directed by the Engineer-in-Charge. |
| 21 | M&L, Mild steel framed work such as in doors/chowkhats or gates of angle or other section with gusset plates, rail, braces etc. complete drilled for fixing of steel sheeting or other covering. Doors etc. to be prepared for hanging or sliding with including either hooks and hinges or steel hanging door fittings (exclusive of steek sheeting or other coveriong, running rails and guides) and hanging, also fastening & fixing and similar work conforming to Fe-290 grade E-165complete all as specified and directed by Engineer-in-Charge |
| 22 | S&F, Aluminium handles ,plate cast type anodised of 150 mm size complete all as specified and directed by Engineer-in-Charge. |
| 23 | S&F, Aluminum anodizes barrel tower bolts of extuded section and fixed of 200 mm size complete all as specified and directed by Engineer-in-Charge |
| 24 | S&F, Butt hinges medium weight cold rolled steel of 100 mm size and fixedcomplete all as specified and directed by the Engineer-in-Charge. |
| 25 | S&F, Aluminum alloy, anodized, door bolt with hasp staple ( bolt type) and fixing clips of sheet,cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed length of bolt 250 mm, bolts not less than 16mm dia with and including a minimum of 6 bolts not,four on bolt plate and two on staple plate complete (ISI marked )complete all as specified and directed by Engineer-in-Charge |
| 26 | S&F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed in wooden/steel/ Aluminium windows, or Stainless steel wire staples complete all as specified and directed by the Engineer-in-Charge. |
| 27 | M&L for Preparing new or previously untreated steel surfaces of any description, over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primercomplete all as specified anddirected by Engineer-in-Charge. |
| 28 | M&L for Preparation of new wooden surfaces of any description, exceeding 10 cm width or girth of any description and applying two coats of synthetic enamel paint over one coat of pink primercomplete all as specified and directed by Engineer-in-Charge |
| 29 | Dismantling structural steel work in including doors, gates ,angles but excluding framed truss etc complete all as specified anddirected by Engineer-in-Charge. |
| 30 | M&L for Cleaning and removing all scale and dirt, etc. using jute brush from inside & outside of 250 litre to 500 litre capacity PVC water tanks and from mouths of connected pipes, removing the scale and dirt etc. to a distanceof not exceeding 500 metre, washing the tanks with water, cleaning the connecting pipes with bleaching powdersolution and finally applying 2% potassium permanganate solution for disinfection, marking with white paint on tank ‘Date of cleaning the tank complete all as specified and directed by the Engineer-in-Charge. |
| 31 | S&F PVCtank lid (cover) suitable for 500/1000 litres capacity water tank with hinged and hooked fixing by steel screw for existing PVC water tank on buildings, fixed in repair complete all as directed by Engineer-in-Charge |
| 32 | S&F, Plastic water closet seat white closed pattern with flat bottom and over and mild steel chromium plated or aluminized hinging device , fixed in repairs complete all as specified and directed by the Engineer-in-Charge. |
| 33 | S&F in repair , Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed in wooden/ steel/Aluminium windows, or Stainless steel wire staples complete all as specified and directed by the Engineer-in-Charge. |
| 34 | Supply only integral water proofing compound ( ISI marked ) complete all as specified and directed by the Engineer-in-Charge. |
| 35 | Taking down existing water proofing treament any nos of layers and of any description, incl.demolition and taking off PCC padding/plaster on RCC slab,also including removing of bitumen coating to show the concrete surfaceto its true colour and roughening etc and also removing the debris outside the MOD land complete all as specified and directed by Engineer-in-Charge |
| 36 | Taking down existing mud puska or lime concrete or brick bats any nos of layers and of any description, including removing of the debris outside the MOD Land complete all as specified and directed by Engineer-in-Charge. |
| 37 | Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 including macthing existing surfaces complete all as specified and directed by Engineer-in-Charge. |
| 38 | M&L Cement concrete type B-0, 1:2:4 (12.5 mm graded stone aggregate) on roof paddingavg. thickness of 40 mmin slope finished even and fair complete all as specified and directed by Engineer-in-Charge. |
| 39 | M & L for15 mm thick Screed bed in cement mortar 1:3 mixed with integral water proofing compound as per manufacturers instrustruction complete all as specified and directed by Engineer-in-Charge. Note: Water proofing compound will be measured paid sesperatly. |
| 40 | M & L for laying APP modified membarane with non woven polyester reinforcement mat (concrete core) not less than 3 mm thick & not less than 3.5 kg /sqm, laping otching shall be 100 mm on length side & 100 mm on widthe sideover a tack coat of Industrial bitumen of 1.20 kg / Sqm over Bituminious based primer IS No. 3383@ 250 gms/sqm including apply of Aluminium colour synthetic enamel paint @ 200 gms/sqm all as per manufacture\"s instructioncomplete all as specified and directed by Engineer-in-Charge.Note: Supply only integral water proofing compound shall be measured and paid separately. |
| 41 | S&F Butt hinges medium weight Stainless steel of 75 mm size and fixedcomplete all as specified and directed by the Engineer-in-Charge. |
| 42 | S&F Factory Made Solid PVC Moulded Door Shutter with wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with2mm thick 3D wood grained printedcolour Moulded PVC Sheet Polyurethane painted on the front face & 2mm Plain colour PVC Sheet on back face, supplying & fixing in frame at site as per specification &drawing complete all as specified and directed by Engineer-in-Charge. |
| 43 | S&F, Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing. (Note:- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and holddoors properly for a long life) complete all as specified and directed by Engineer-in-Charge. |
| 44 | Dismantling of stone slabs & pavers blocks/tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed by the Engineer-in-Charge. |
| 45 | M&L for Granite 20 mm thick (of any type ) (table runned and polished ) in floors steps , jamns, pillars,window-cills,cooking plateforms and vertical surfaces bedded and jointed with grey cement slurry and pointing in white ciment (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by the Engineer-in-Charge. |
| 46 | M&L 75 mm thick cement concrete type C2 1:3:6 (40 mm graded stone aggregate) as in plinth protection, finished the surface even & smooth with using extra cement laid in panels complete all as specified and directed by the Engineer-in-Charge. |
| 47 | Supply and fixed in repair vitreous china wash hand basin including brackets, white size 550 x 400 mm incl cutting cutting for and pinning in ends of brackets. Including Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed complete all as specified and directed by the Engineer-in-Charge. |
| 48 | S&F in repair 15 mm dia bib tap cast copper alloy(fancy type), chromium plated ,\"with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete all as specified and directed by the Engineer-in-Charge. |
| 49 | S&F in repair Bib tap standard of PTMT 15mm any colour high pressure screwed for iron pipe and fixed.(Minimumweight15mm-90gms) complete all as specified and directed by the Engineer-in-Charge. |
| 50 | S&F in repair, stop valve, cast copper alloy, with crutch or butterfly handle, screwed down both ends for high pressure, as per ISI suitable for 15mm dia iron pipe complete all as specified and directed by the Engineer-in-Charge. |
| 51 | S&F in repair fancy type pillar tap, cast copper alloy with capstan heads,chromium plated, screwed down high pressure, with or without lettered\"Hot\" or \"Cold\"with long screwed shanks & fly nuts, screwed for iron pipes of 15mm bore complete all as specified and directed by the Engineer-in-Charge. |
| 52 | S&F in repairs 125 mm dia, chromium plated shower rose with or without swivel joints,including fixing to steelpipe or ounion of 15mm bore complete all as specified and directed by the Engineer-in-Charge. |
| 53 | S&F in repair of PVC low level flushing cistern dual flush top push,10 Ltr capacity syphonic action type white as approved, ball valve float valve and handle, flush pipe incl CP bracket complete all as specified and directed by the Engineer-in-Charge. |
| 54 | S&F in repairs PVC connection 15mm size with PTMT nuts, of 450 mm length complete all as specified and directed. |
| 55 | S&F in repairs 600x450 mm size of 5.5mm thickness looking mirror, bevelled edge of selected quality glass with aluminium frame made of channel alround,mounted on 6 mm thick commercial ply or AC building board, fitted to wooden plug with CP screws complete all as specified and directed. |
| 56 | S&F in repairs, grating doom 125 mm dia with waste hole of SS complete all as specified and directed by the Engineer-in-Charge. |
| 57 | S&F in repairs CP Health Faucet with 1 mtr metalic Expandable tube & hook complete all as specified and directed by the Engineer-in-Charge. |
| 58 | S&F in repairs CP wall mixer (3 in 1) 15mm complete all as specified and directed by the Engineer-in-Charge. |
| 59 | S&F in repairs vitreous china water closet (squatt pan) orrisa pattern 580x440 mm size pan white withfront or back inlet with integral \"foot rests including provn of lime concrete beddingconnections to \"flushing cistern/pipe & 100mm CI \"P\" trap complete all as specified and directed by the Engineer-in-Charge. |
| 60 | S&F in repairs vitreous china water closet Padestal pattern (white) excluding fixing bolts, flushing cistern and flush pipe and including EWC Sheet cover complete all as specified and directed by the Engineer-in-Charge. |
| 61 | S & F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed by the Engineer-in-Charge. |
| 62 | S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed by the Engineer-in-Charge. |
| 63 | S&F PVC waste pipe, 32mm bore, 750mm long for basin, fixed in repair,complete all as specified and directed by the Engineer-in-Charge. |
| 64 | M& L for point wiring with FRLS PVC insulated ,unsheathed cable with multi stranded copper conductor 2X1.5 sqmm single core 1100 Volt grade confirming to IS :694 and including surface mounted drawn through ERW steel conduitnot less than 20 mm dia includingconduit and conduit accessories fixed on wall /ceiling including 1x1.5 sqmm PVC insulated unsheathed multi stranded copper conductor FRLS sinlge core (green colour ) as earth continuity conductor up to common earth and connected to common earth dolly forlight point/fan control by one switch incl taking down complete all as specified and directed by the Engineer-in-Charge.Note :-(i) Flame proof switch shall be measured and paidseperately(ii) All coduit accessoried such as bends, Elbows, Tee, reducers, junction box etcdeemed to beincluded in the rate quoted . |
| 65 | S &F forFlame proof rotory switch with termination box in LM-6 inclosed inand including aluminium body enclosure with threaded cover and toggle actionswitch operated by shrouded knob single pole 16 Amps, 250V, 2P+ Earth with double direct entries through way switch including 20 mm dia ERW threaded rigid steel conduit complete all as specified and directed by the Engineer-in-Charge. |
| 66 | M&L forrigid stove enamelled conduit welded not less than 20/25 mm dia incl tees bends etc fixed with suitable clamps with proper screws complete all as specified and directed by the Engineer-in-Charge. |
| 67 | S&F junction box flame proof 20/ 25mm terminals with threaded covercomplete all as specified and directed by Engineer-in-Charge. |
| 68 | Supply and fixing LED light fitting 1x20 Watt flame proof, CMRI certified recommended for gas/vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed by the Engineer-in-Charge. |
| 69 | S & F flame proof distribution board SPN 08 way with Bus bar weather proof in cast aluminium LM-06 enclosure operated by externally spring type knobscomplete with M-25 cable entry to suit incoming cable and 08 Nos M-20 cable entries for out going from bottom, suitable for fixing on wall/column /steel structure duly epoxy powder coated with flame proof flexible metallic conduit up to 01 Mtr length complete all as specified and directed by the Engineer-in-Charge. |
| 70 | S&F in replacement ofFLP-WP ceiling fan 1200mm sweep single phase in cast aluminium LM 6 Complete with all accessories prewired and including connecting up with three coreflexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge.Note:- Old U/S fan will be deposit in MES store. |
| 71 | S&F for commissioning & testing ESE based lightining arresstor Model name , Protech Streamer 20 (Protected area 32 meter Radius on Level 1 and 77 meter Radius on Level III ) single spike complete with chemical earthing all connections andacceessories for a range of 25 mtrs complete all as specified and directed by the Engineer-in-Charge. |
| 72 | M&L in repairs for stranded copper conductor cable of size 70sqmm single core insulated flexible copper down conductor (cable) fromLightning arrester to Earthing properly fixed with saddles and on insulators complete all as specified and directed by the Engineer-in-Charge. |
| 73 | M&L for installtion of GI Mast with insulator and necessary accessories 5 Mtr height incl all necy civil and grouting works, nuts bolts washers complete all as specified and directed by the Engineer-in-Charge. |
| 74 | S&F in replacement Lightning Strike Counter ( 6 digit ) incl all connections , fixing on wall etc nuts bolts complete all as specified and directed by the Engineer-in-Charge. |
| 75 | M &L in repairs ofAir termination single pointed Aluminium rod 12 mm dia and 300 mm long complete all as specified and directed by the Engineer-in-Charge. |
| 76 | M &L in repairs ofAir termination single pointed copper rod 12 mm dia and 300 mm long complete all as specified and directed by the Engineer-in-Charge. |
| 77 | S&F in replacement for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by the Engineer-in-Charge. |
| 78 | S&F in replacement ofold u/s Ceramic insulator of standard size for ligthning strip protection fixed in wall of one mtr distance with suitable size screws complete all as specified and directed by the Engineer-in-Charge. |
| 79 | S&F in replacement ofold u/s Copper strip 20 x 3.15mm fixed with top of insulator/saddles, fixing with screws , washer etc with help of drill machine for roof conductors and down conductors above ground and and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by the Engineer-in-Charge. |
| 80 | S&F in replacement ofold u/s Aluminium strip 25 x 3.15mm fixed with top of insulator/saddles, fixing with screws , washer etc with help of drill machine for roof conductors and down conductors above ground and and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by the Engineer-in-Charge. |
| 81 | M&L for Chemical earthing , Design development supply commissioning and testing EHCC certified ground terminal earthing system hollow tube solid bar CCPRI tested for sensitive signal/Electrical equipments highly anti corrosive long life severe wear conditions in the earth pit and of standardsize ISI marked copper tube out side secondary conductor of 50mm dia and main primary conductor inside 25mm dia 3000mm length ready to install with suitable connecting terminal confirming to IS:3043 1987 specification highly conducive packing material to be filled in earth pits for providing uniform low resistivity anti corrosive hygroscopic medium around the earth system for improving the efficency of current dissipation 20 Kg per bag (3 bag per kit) min or sufficeient quantities required as per site complete incl PCC pits of inside dimension 0.5x0.5x0.5m and suitable cover complete all as specified and directed by the Engineer-in-Charge.Note:(i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers complete labour, testing, Earth lead/strip upto 7.5 mtr, char coal dust, common salt, porcelain insulator,PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh are incl in quoted rate andwatering pipe, earth lead protection pipe, test poit, and earth lead exceeding 7.5 mtr are measured and paid separately. |
| 82 | M&Lfor Providing,PCC 1:3:6 type C-1 using 20 mm graded stone aggreat,for damaged earth pit chamber with fair finish internal surface of concrete chamber of earth complete all as specified and directed by the Engineer-in-Charge. |
| 83 | S&F in replacement of80 mm thick PCC pit cover 320 mm x 320 mm of PCC 1:2:4 TYPE B-1 using 20 MM graded stone aggregate including necesssary form work and handle for removing the cover from pit with fair finish complete all as specified and directed by the Engineer-in-Charge. |
| 84 | M&L for earthing complete with galvanized steel plate earth electrode 60cmx60cmx6mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less then 1.5 mtr below ground level surrounded from all sides by char coal dust and common saltin alternate layersof 15 cm depth and earth plate electrode connected to galvanised earth lead wire of 4.0mm dia at two points by means of GI nuts bolts, check nuts and washers and connected to earthling test point drawn through GI pipe for protection of earth lead wire and arrangement of watering pipe incl PCC earth pit (1:3:6) type C-2 with CI frame andRCC cover all as shown in electrical Plate No 3 on SSR Part-Iincluding testing and dismantling ,taking down old unser earthing complete all as specified and directed by the Engineer-in-Charge.Note:(i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers complete labour, testing, Earth lead upto 7.5 mtr, char coal dust, common salt, porcelain insulator, PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh are incl in quoted rate andwatering pipe, earth lead protection pipe, test poit, earth lead exceeding 7.5 mt are measured and paid separately. |
| 85 | All as per item No 84 above but using GI Strip 25x4 mm as earthing lead. |
| 86 | M&L for earthing complete with copper plate earth electrode 60cmx60cmx3.15mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less then 1.5 mtr below ground level surrounded from all sides by char coal dust and common saltin alternate layersof 15 cm depth and earth plate electrode connected to copper earth lead strip of size 20X3.0 mm at two points by means of GI nuts bolts, check nuts and washers and connected to earthling test point drawn through 40 mm dia GI pipe for protection pipe and arrangement of watering pipe incl PCC earth pit (1:3:6) type C-2 with CI frame andRCC cover all as shown in electrical Plate No 3 on SSR Part-Iincluding testing and dismantling ,taking down old unser earthing all as directed by Engr-In-Charge.Note:(i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers complete labour, testing, Earth lead/strip upto 7.5 mtr, char coal dust, common salt, porcelain insulator,PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh are incl in quoted rate andwatering pipe, earth lead protection pipe, test poit, and earth lead exceeding 7.5 mtr are measured and paid separately. |
| 87 | Supply and fixing in repairof Earth continuity strip or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or fixed on wall with porcelain insulator or any other indicated situation for loop earthing etc. as required 20x3.0mm copper strip complete all as specified and directed by the Engineer-in-Charge. |
| 88 | Supply and fixing in repair of Earth continuity GI wire of 4 mm dia or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed by the Engineer-in-Charge. |
| 89 | Supply and fixing in repair of Earth continuity strip or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or fixed on wall with porcelain insulator or any other indicated situation for loop earthing etc. as required 25x4 mm GI strip complete all as specified and directed by the Engineer-in-Charge. |
| 90 | Supply and fixing in replacement ofofold u/s ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 245 CFM with service . Five star rated complete all as specified and directed by Engineer-in-Charge.Note:- Old u/s fan will be deposit in MES store. |
| 91 | Supply, Fixing & layingGI tubing lightgrade 20 mm dia used as protection pipe for earth lead wire in earthing complete all as specified and directed by the Engineer-in-Charge.Note: All required items and accessories , bend, joints, nut bolts, clamps etc are incl in quoted rates. |
| 92 | Supply , Fixing & layingGI tubing lightgrade 40 mm dia used as protection pipe for earth lead strip in earthing or alongwith pole / wall/ culvert / drainage etc for mechanical protection of cablecomplete all as specified and directed by the Engineer-in-Charge. Note: All required items and accessories , bend, joints, nut bolts, clamps etc are incl in quoted rates. |
| 93 | Supply, installation , commissioning and testingof LTPaneloutdoor type factory made out of CRCAsheet 3.15 mm thick and size 950x950x450mm dust & vermin proof , frontand rear openingshutters having locking arrangementtotally enclosed weather proof, antirusted powder coated including aluminium Bus Barof 320 Ampsrating of suitable length, 440 volts, 3 Phase 4 wire50 Hz mountedon suitable type ofinsulators.complete withbottom removable gland plates, as required, all internalconnection wiring bymin. 2.5 Sqmm. copper wires, Panel shall be comprising ofseperate chambers / modules / compartment to accomodate incomer MCCB, outgoing MCCB andinstrument chamber comprise of digital Ammeter & voltmeter flush mounted, selector switches, RYB indicator ,CT\"s,etc complete mounted on suitable size of MS angle framestandof minimum 45 cmheight from ground l;evelinclPCCand earhwork required to fix the stand complete all as specified and directed by Engineer-in-Charge. The panel board shall be comprising of the following :-(a) Incommer - MCCB 4 POLE 415 V 160 A (35 kA)- 01 NoOutgoing :-(b)MCCB 4 POLE 415 V32 A (25 kA)- 02 Nos(c ) MCCB 4 POLE 415 V63 A (25 kA) - 02 Nos(d)Blank chamber - 01 No with din rail sutable for fixing04 Nos TP/TPN MCBsNotes - (i) Drawing of panel should be approved from GE before despatch.(ii) Panel should be CPRI approved and certified.(iii) MCCB should be adjustable type. |