Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Repairs, Maintenance & Modernization of Pt.Ram Naresh Tripathi Sabhaghar Sultanpur U.P. |
| 2 | Dismantling of existing false ceiling & dispose of malwa… etc complete. Quotation Attached. |
| 3 | Providing and fixing ofAcoustic Mineral fiber tile 600 X 600mm on 24mm powder coated G.I grid system with all accessories hardware and installation charges complete.Quotation Attached. |
| 4 | Providing & fixing of Acoustical wall paneling including all accessories hardware and installation charges Quotation Attached. |
| 5 | Dismantling of wall paneling Quotation Attached. |
| 6 | Providing & fixing of AC 2 Ton capacity each The cost is inclusive of machine + hardware copper pipe accessories and installation charges Machine 15 nos, 15 stablizer andLow side work 23 nos…etc complete work.Quotation Attached. |
| 7 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofingement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.For the purpose of measurement the entire treated surface will be measured. |
| 8 | Providing and fixing of anti-termite chemical treatment.Quotation Attached. |
| 9 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40 mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work ofleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge |
| 10 | Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works. |
| 11 | P/A 2mm thickness wall putty…..etc complete work SI NO.13 Ref.13.26 |
| 12 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 13 | Colour washing such as green, blue or buff to give an even shade : |
| 14 | New work (two or more coats) with a base coat of white washing with lime |
| 15 | Finishing walls with water proofing cement paint of required shade : |
| 16 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 17 | Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 18 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : |
| 19 | 5.5 mm thick glass panes |
| 20 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 21 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 22 | Powder coated aluminium (minimumthickness of powder coating 50 micron) |
| 23 | Proving and fixing of wooden doors including chaukhat panelingtotal doors 14 nos including all accessories hardware and installation charges Quotation Attached. |
| 24 | Proving and fixing of nonwoven carpet tile flooring on stage area and common walk way area at auditorium.Quotation Attached. |
| 25 | Removing old tarfelt sheet Providing & fixing of Bitumen Roof Tarfelt Sheet, for water proofing on shed area on the roof. Quotation Attached. |
| 26 | CCTV CAMERA Quotation Attached. |
| 27 | Sound system Quotation Attached. |
| 28 | Providing and fixing of curtain on stage side portion and all doors Quotation Attached. |
| 29 | Table 5’ x 2’.5’’ Quotation Attached. |
| 30 | Sofa 3 SeaterQuotation Attached. |
| 31 | Iron Gate with ACP work with glowing signboard & Incl. electric work…..etc complete work Quotation Attached. |
| 32 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 33 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 34 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 35 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 36 | Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
| 37 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 38 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 39 | P/A 15mm thick plaster cement & coarse sand mortar ratio (1:4) ……..etc complete. SI No.3 13.5.1 |
| 40 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). |
| 41 | SCHEDULE OF QUANTITIES FOR PLUMBING WORKS |
| 42 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required |
| 43 | W.C. pan with ISI marked white plastic seat and lid |
| 44 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 45 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. |
| 46 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 47 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. |
| 48 | Semi rigid pipe |
| 49 | a) 32mm dia |
| 50 | b) 40mm dia |
| 51 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required |
| 52 | a) One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 53 | b)Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern |
| 54 | Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. |
| 55 | Granite Stone of approved shade |
| 56 | Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge. |
| 57 | 15mm nominal bore |
| 58 | Providing and fixing Toilet paper holder |
| 59 | a) C.P. brass |
| 60 | Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms. |
| 61 | Providing & fixing soil, waste and vent pipes. |
| 62 | a) 100mm dia centrifugally cast iron S & S pipe as per IS:3989 |
| 63 | b) 75mm dia centrifugally cast iron S & S pipe as per IS:3989 |
| 64 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. |
| 65 | a) 100mm |
| 66 | b) 75mm |
| 67 | Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. |
| 68 | a) For 100mm dia pipe. |
| 69 | b) For 75mm dia pipe. |
| 70 | Providing & fixingcast iron coller. |
| 71 | 100mm dia. |
| 72 | 75mm dia. |
| 73 | Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. |
| 74 | 100mm inlet & 75mm outlet. |
| 75 | Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. |
| 76 | 100mm |
| 77 | 75mm |
| 78 | Providing and fixing plain cast iron S & S sanitary bend. |
| 79 | 100mm |
| 80 | 75mm |
| 81 | Providing and fixing centrifugaly cast iron single equal plain junction of required degree. |
| 82 | 100x100x100mm |
| 83 | 75x75x75mm |
| 84 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 85 | internal work -Exposed on wall |
| 86 | 20mm dia nominal outer dia pipes |
| 87 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. |
| 88 | Concealed work including cutting chases and making good the walls etc. |
| 89 | 15mm dia nominal outer dia pipes |
| 90 | 20mm dia nominal outer dia pipes |
| 91 | Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. |
| 92 | 15mm nominal bore |
| 93 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 |
| 94 | 15mm nominal bore |
| 95 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 |
| 96 | 15mm nominal bore |
| 97 | Providing & fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 98 | Providing and fixing gun metal gate valve with wheel of approved quality. |
| 99 | 25mm dia nominal bore |
| 100 | 20 mm dia nominal bore |
| 101 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete |
| 102 | 25 mm nominal bore |
| 103 | Providing and fixing high density ploythylene water storage loft tank with cover, confirming to IS:12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet and overflow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. |
| 104 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, |
| 105 | in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. |
| 106 | Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. |
| 107 | Providing, laying and joining glazed stone ware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. |
| 108 | 100mm diameter |
| 109 | 150mm diameter |
| 110 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. |
| 111 | 100mm diameterS.W. Pipe |
| 112 | 150mm diameterS.W. Pipe |
| 113 | Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design: |
| 114 | 150 x 100 mm. size P type |
| 115 | With Sewer bricks conforming to IS : 4885 |
| 116 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design |
| 117 | Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). |
| 118 | With FPS bricks of class designation 75 |
| 119 | (i) For Sewer Line |
| 120 | Extra for depth of man hole size 90x80 cm |
| 121 | Inside size 90x120 cm & 90 cm deep including C.I. cover with frame (medium duty) total wt. of cover & frame to be not less than 116 Kg (wt. of cover 58 Kg & wt. of frame 58 Kg. |
| 122 | Extra for depth of man hole size 90x120 cm |
| 123 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design |
| 124 | With 20x20 mm square bar |
| 125 | POINT WIRING |
| 126 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 127 | Group C |
| 128 | Wiring for circuit/sub-main wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVCconduit as required. |
| 129 | 2X1.5 sqmm + 1x1.5 sqmm earth wire |
| 130 | 2X2.5 sqmm + 1x 2.5 sqmm earth wire |
| 131 | 2X4.0 sqmm + 1x 4.0 sqmm earth wire |
| 132 | 2X6.0 sqmm + 1x 6.0 sqmm earth wire |
| 133 | 2X10.0 sqmm + 1x 6.0 sqmm earth wire |
| 134 | 4X6 sqmm + 2x 6.0 sqmm earth wire |
| 135 | 4X10 sqmm + 2x 6.0 sqmm earth wire |
| 136 | 4X16 sqmm + 2x 6.0 sqmm earth wire |
| 137 | Supplying and drawing following pair 0.5 sqmm FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. |
| 138 | 2 Pair |
| 139 | Supplying and drawing co-axial TV cable RG-6 graded, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 140 | Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: |
| 141 | 25mm |
| 142 | Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc as required. |
| 143 | Telephone socket outlet |
| 144 | TV antenna socket outlet |
| 145 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 146 | Supplying and fixingfollowing size/modules, GI box along with modular base& cover plate for modular switches in recess etc as required. |
| 147 | 1 or 2 module(75mm X 75 mm ) |
| 148 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch,connection etc. as required. |
| 149 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,connection etc. as required. |
| 150 | Supplying and fixing 3 pin 5 A ceiling rose on the existing junction box/woodedn block including connectionetc. as required. |
| 151 | Instalation,testing & commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories including connection etc. as required. |
| 152 | Installation, testing and commissioning of prewired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required. |
| 153 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
| 154 | Installation of exhaust fan in the existing opening, including making good the damage, connections, testing, commissioning etc. as required. |
| 155 | upto 450 mm sweep. |
| 156 | Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes. |
| 157 | DISTRIBUTION BOARDS, MCB\"S & ISOLATORS : |
| 158 | Supplying and fixing followingway, Horizontal type three pole and neutral MCB distribution board, 415 volts on surface /recess completewith , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). |
| 159 | 4 way (4 + 12), Double door |
| 160 | 6 way (4 + 18), Double door |
| 161 | Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C\" series,miniature circuit breaker (MCB) suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required. |
| 162 | Single Pole |
| 163 | Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required. |
| 164 | Supply and fixing following rateing four pole, 415 V, isolator in the existing existingMCBDBcomplete with connections, testing andcommissioning etc. as required. |
| 165 | 40 A |
| 166 | 63 A |
| 167 | Supply and fixing 20 amp, 240 volts, SPN industrial Type, socket outlet ,With 2 pole and earth ,metalenclosed plug top along wth 25/32 amp. `C` series SPMCB , in sheet steel encosure, on surface or in recess with chained metal cover for the socket out letand complete with connections, testing and commissioning etc. as required. |
| 168 | Supply and fixing30 amp, 415 volts, TPN industrial Type, socket outlet ,With 4 pole and earth ,metalenclosed plug top along wth 30 amp. `C` series TPMCB , in sheet steel encosure, on surface or in recess with chained metal cover for the socket out letand complete with connections, testing and commissioning etc. as required. |
| 169 | Providing and fixing M.V. danger notice plate of 200 mmx150 mm, made of mild steelm at least 2 mm thick, and viterous enameled whithe on bothe sides, and with incription in single red colour on front side as required. |
| 170 | Suplying and fixing cable end box(Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution borad, 415 Volts, on surface/recess, complete with testing and commissoning ect. As required. |
| 171 | For 4 way, Double Door TPNMCBDB |
| 172 | For 6 way, Double Door TPNMCBDB |
| 173 | Supply and installing of following size of perforated Hot Dipped Galvanised Iron cable trays (Galvanisation thickness not less 50 miccrons) with preforation not more than 17.5%, in convenient sections, jointed with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts etc as required |
| 174 | 300mmwidth x 50mm depth x 1.6 mm thickness |
| 175 | Earthing with GI earth pipe, 600 mm X 600 mm X 6 mm thick including accessories and providing masonary enclosure withcover platehavinglockingarrangement and watering pipe of 2.7 metre long etc, with charcoal/cock and salt as required. |
| 176 | Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 177 | Supplying and Laying of 6 SWG G.I wire at 0.50 metre below ground level for conductor earth electrode, including connection / terminating with G.I. thimble etc. as required. |
| 178 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. |
| 179 | Upto 35 sq. mm |
| 180 | Above 95 sq. mm and Upto 185 sq. mm. |
| 181 | Supplying & making end termination with brass compression gland and aluminium lugs for the following size of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 182 | 3.5 X 120 sqmm. (45mm) |
| 183 | CABLES |
| 184 | Supply of following size of 1.1 KV grade multicore aluminium conductor PVC sheathed armoured cable as per IS 1554. Make-Polycab or Eq |
| 185 | 120 sqmm 3.5 core |
| 186 | L.T. PANEL |
| 187 | Supply, & Erraction of factory fabricated & wired metal clad dust and vermin proof floor mounted,M.S. channel base with bottom and top cable entreis electrical control panel with TPN MCCB\"s (four pole 36 KA with thermal magnatic release ) switches complete and instrument chamber etc. complete in all respects. the instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase votage and single phase voltage, current and other parameters(KVA,PF,KW etc) in each phase with touchtype selector switches for different reading instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic aluminium basbar as per IS 8623 or above insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. the MCCB\"s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. |
| 188 | the job includes the grounting of the board as per directions of Engineer-incharge. All out going of 100 Amp and above shall have an Ammeter. the panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. cubicle type switch board shall be of cat A & B only. |
| 189 | Incoming : |
| 190 | 200 Amp. MCCB - 1No |
| 191 | Cat. B Panel Cubicale Type |
| 192 | Metering : |
| 193 | One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. |
| 194 | One (1) No. (0-200A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. |
| 195 | One (1) Set of Phase Indication Lamp. |
| 196 | Bus Bar : |
| 197 | One (1) No.250 A, TPN aluminimum bus bar of suitable length. |
| 198 | Outgoing : |
| 199 | Phase indication lamps on each outgoing to be provided. |
| 200 | 100Amp 4P MCCB - 1No. |
| 201 | 63Amp 4P MCB - 3No. |
| 202 | 40Amp 4P MCB - 2No. |
| 203 | 63Amp 4P MCB - 1Nos.-Spare |
| 204 | 40Amp 4P MCB - 1Nos.-Spare |
| 205 | SUPPLY OF LIGHT FIXTURES : |
| 206 | Supply of1X17 W mirror light complete in all respects. Make-Philips or Eq |
| 207 | Supply ofLED Tube Light with batten suitable for up to 1X20 watt LED tube light complete including tube etc. on surface/Pendent complete in all respect.Make-Philips or Eq |
| 208 | Supply of recess/Surface/Pendent mounting round 10 to 15 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respects.Make-Philips or Eq |
| 209 | Supply of 36 Watt above 3300 leumin indoor recess/Surface/Pendent mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing withextendedheat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect.Make-Philips or Eq |
| 210 | Supplyof AC 230/250 Volts, 50 Hz 55w 1400 rpm exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required.Make: Havells-STANDARD -Refresh Air-SPS |
| 211 | 300mm sweep. |
| 212 | Supply & erection ofHigh speed Wall FanAC 230/250 Volts, 50 Hz 110w 1750 rpm including nuts, bolts, mounting frame and other accessorieswith connections etc. complete as required. Make: Havells-STANDARD -SW 18 |
| 213 | 450 mm sweep. |
| 214 | Supplying and fixing of 1 No. 16 A modular switch and 2 Nos. 6A modular socket & 1 No.16 A modular socket including metal box (recessed/ surface) |
| 215 | ESTIMATEFORRAIN WATER HARVESTING WORKS |
| 216 | Earth work in excavation by mechanical means (Hydraulic excavatior)/manual means over areas(exceeding 30cm in depth. 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. |
| 217 | In all kind of soil upto 1.5m depth |
| 218 | In all kind of soil upto 1.5m to 3.0m. depth |
| 219 | In all kind of soil upto 3.0m to 4.5m. depth |
| 220 | In all kind of soil upto 4.5m to 6.0m. Depth |
| 221 | Providing and laying in position cement concrete of specified grade excluding the ccost of centering and shuttering -All work up to plinth level: |
| 222 | 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 223 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 224 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 225 | Reinforced cement concrete work inbeams, suspended floors, roofs having slope up to 15º landings, balconies, shelves, chajjas, intels, bands plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand :3 graded stone aggregate 20mm nominal size) |
| 226 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 227 | Mild steel and Medium Tnsile steel bars. |
| 228 | Centring and shuttering including struting , proping etc and removal of form for : |
| 229 | Suspended floors, roofs, landings, balconies and access platform. |
| 230 | 15mm cement plaster on rough side of single or half brick wall mix |
| 231 | 1:4 (1 cement : 4 coarse sand) |
| 232 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: |
| 233 | With 20x20mm square bar |
| 234 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 235 | M.D. -10- Circular shape 500mm internal diameter |
| 236 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-incharge, upto 90 metre depth below ground level. |
| 237 | Drilling of 300mm dia bore hole manually. |
| 238 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. |
| 239 | 150 mm nominal size dia |
| 240 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 241 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 242 | Supplying, filling, spreading & leveling coarase sand of size range 1.5 mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 243 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 244 | Earth work in excavation by mechanical means (Hydraulic excavatior)/manual means over areas(exceeding 30cm in depth. 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. |
| 245 | In all kind of soil upto 1.5m depth |
| 246 | In all kind of soil upto 1.5m to 3.0m. depth |
| 247 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level: |
| 248 | 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 249 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 250 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 251 | Reinforced cement concrete work inbeams, suspended floors, roofs having slope up to 15º landings, balconies, shelves, chajjas, intels, bands plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand :3 graded stone aggregate 20mm nominal size) |
| 252 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 253 | Mild steel and Medium Tnsile steel bars. |
| 254 | 15mm cement plaster on rough side of single or half brick wall mix |
| 255 | 1:4 (1 cement : 4 coarse sand) |
| 256 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: |
| 257 | With 20x20mm square bar |
| 258 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 259 | M.D. -10- Circular shape 500mm internal diameter |
| 260 | EXTERNAL PIPE NETWORK SYSTEM |
| 261 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, |
| 262 | in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. |
| 263 | Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. |
| 264 | Providing, laying and joining glazed stone ware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. |
| 265 | 150mm diameter |
| 266 | 200mm diameter |
| 267 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. |
| 268 | 150mm diameterS.W. Pipe |
| 269 | 200mm diameterS.W. Pipe |
| 270 | Constructing brick masonry manhole with 75 class designation F.P.S. bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4graded stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix |
| 271 | (1 cement :4coarse sand: 8 graded stone aggregate 40mm nominal size) inside plasstering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 |
| 272 | (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. |
| 273 | a) Inside size 60x60 cm & 60 cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg (wt. of cover 23 Kg & wt. of frame 15 Kg. |
| 274 | GST EXTRA AS APPLLICABLE |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy