Tender For Special Repair & Maintenance Work Of Institution For Children With Special Abilities (Girls) At Sundernagar, District Mandi, Himachal Pradesh, sundernagar-Himachal Pradesh

Wapcos Limited has published Tender For Special Repair & Maintenance Work Of Institution For Children With Special Abilities (Girls) At Sundernagar, District Mandi, Himachal Pradesh. Submission Date for this Tender is 21-05-2024. Dismantling Work Tenders in sundernagar Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43278768
Tender For Special Repair & Maintenance Work Of Institution For Children With Special Abilities (Girls) At Sundernagar, District Mandi, Himachal Pradesh
Open Tender
Indian
Himachal Pradesh
sundernagar
21-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Special Repair & Maintenance Work Of Institution For Children With Special Abilities ( Girls ) At Sundernagar, District Mandi, Himachal Pradesh; 1 Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls ( Any Thickness ) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Sunken Floor Etc., Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering And Finishing : 2 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) 3 1:3:6 ( 1 Cement : 3 Coarse Sand Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) 4 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. 5 All Works Above Plinth Level Upto Floor V Level 6 Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg / Cum 7 Reinforcement For Rcc Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete. Above Plinth Level. 8 Thermo-Mechanically Treated Bars 9 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : 10 Suspended Floors, Roofs, Landings, Balconies, And Access Platform 11 Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers 12 Columns, Pillars, Piers, Abutments, Posts And Struts 13 Extra For Shuttering In Circular Work ( 20% Of Respective Centering And Shuttering Items ) 14 Shelves 15 Small Lintels Not Exceeding 1.5 M Clear Span, Moulding As In Cornices, Window Sills, String Courses, Bands, Copings, Bed Plates, Anchor Blocks And The Like 16 Edges Of Slabs And Breaks In Floors And Walls 17 Under 20 Cm Wide 18 Weather Shade, Chajjas, Corbels Etc., Including Edges 19 Walls ( Any Thickness ) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. 20 Stairs, ( Excluding Landings ) Except Spiral-Staircases 21 Extra For Additional Height In Centering, Shuttering Where Ever Required With Adequate Bracing, Propping Etc., Including Cost Of De-Shuttering And Decentering At All Levels, Over A Height Of 3.5 M, For Every Additional Height Of 1 Metre Or Part Thereof ( Plan Area To Be Measured ) . 22 Suspended Floors, Roofs, Landing, Beams And Balconies ( Plan Area To Be Measured ) 23 Add For Plaster Drip Course / Groove In Plastered Surface Or Moulding To R.C.C. Projections. 24 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : 25 Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 26 Half Brick Masonry With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. 27 Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) 28 Extra For Providing And Placing In Position 2 Nos 6Mm Dia. M.S. Bars At Every Third Course Of Half Brick Masonry. 29 Providing And Filling Aac Blocks Including Proper Watering And Compaction In Sunken Areas All Complete As Per Drawings And As Directed By The Engineer-In-Chargein-Charge. 30 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Edge Moulding, Facia And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. 31 Granite Of Any Colour And Shade 32 Area Of Slab Upto 0.50 Sqm 33 Area Of Slab Over 0.50 Sum. 34 Extra For Providing Opening Of Required Size & Shape For Wash Basin / Kitchen Sink In Kitchen Platform, Vanity Counter And Similar Location In Marble / Granite / Stone Work, Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. 35 Providing And Fixing Stone Slab With Table Rubbed, Edges Rounded And Polished, Of Size 75X50 Cm Deep And 1.8 Cm Thick, Fixed In Urinal Partitions By Cutting A Chase Of Appropriate Width With Chase Cutter And Embedding The Stone In The Chase With Epoxy Grout Or With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 6 Mm Nominal Size ) As Per Direction Of Engineer-In-Charge And Finished Smooth. 36 Granite Stone Of Approved Shade 37 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately ) . 38 Second Class Teak Wood 39 Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 ( Part I ) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters: 40 35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws 41 Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters ( Over All Area Of Door Shutter To Be Measured ) . 42 Extra For Providing Vision Panel Not Exceeding 0.1 Sqm In All Type Of Flush Doors ( Cost Of Glass Excluded ) ( Overall Area Of Door Shutter To Be Measured ) : 43 Rectangular Or Square 44 Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 45 250X10 Mm 46 100X10 Mm 47 Providing And Fixing Stainless Steel Fancy Handle Of Approved Make Fixed With Ss Screws Etc. Complete As Per Direction Of Engineer-In-Charge. 48 200Mm 49 Providing And Fixing Bright Finished 100 Mm Mortice Lock With 6 Levers Without Pair Of Handles Of Approved Quality For Aluminium Door, With Necessary Screws Etc Complete As Per Direction Of Engineer- In-Charge. 50 Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete 51 Twin Rubber Stopper 52 Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer ( Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm ) , With Necessary Accessories And Screws Etc. Complete. 53 Providing 40X5 Mm Flat Iron Hold Fast 40 Cm Long Including Fixing To Frame With 10 Mm Diameter Bolts, Nuts And Wooden Plugs And Embedding In Cement Concrete Block 30X10x15cm 1:3:6 Mix ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size ) . 54 Providing & Fixing Decorative High Pressure Laminated Sheet Of Plain / Wood Grain In Gloss / Matt / Suede Finish With High Density Protective Surface Layer And Reverse Side Of Adhesive Bonding Quality Conforming To Is : 2046 Type S, Including Cost Of Adhesive Of Approved Quality. 55 1.5 Mm Thick 56 Providing And Fixing Fire Resistant Door Frame Of Section 50 X 60 Mm On Horizontal Side & 35 X 60 Mm On Vertical Sides Having Built In Rebate Made Out Of 1.6 Mm Thick Gi Sheet ( Zinc Coating Not Less Than 120Gm / Sqm ) Suitable For Mounting 120 Minutes Fire Rated Glazed Door Shutters. The Frame Shall Be Filled With Mineral Wool Insulation Having Density Minimum 96Kg / Cum. The Frame Will Have A Provision Of G.I. Anchor Fastners 14 Nos ( 5 Each On Vertical Style & 4 On Horizontal Style Of Size M10 X 80 ) Suitable For Fixing In The Opening Along With Factory Made Template For Ss Ball Bearing Hinges Of Size 100X89x3mm For Fixing Of Fire Rated Glazed Shutter . The Frame Shall Be Finished With A Approved Fire Resistant Primer Or Powder Coating Of Not Less Than 30 Micron In Desired Shade As Per The Directions Of Engineer - In- Charge . ( Cost Of Ss Ball Bearing Hinges Is Excluded ) . 57 Providing And Fixing 60 Mm Thick Glazed Fire Resistant Door Shutters Of 120 Minutes Fire Rating Confirming To Is:3614 ( Part Ii ) Or En1634-1:1999, Tested And Certified As Per Laboratory Approved By Engineer-In-Charge, With Suitable Mounting On Door Frame, Consisting Of Vertical Styles, Top Rail & Side Rail 60 Mm X 60 Mm Wide And Bottom Rail Of 110 Mm X 60 Mm Made Out Of 1.6Mm Thick G.I. Sheet ( Zinc Coating Not Less Than 120Gm / Sqm ) Duly Filled Mineral Wool Insulation Having Density Minimum 96 Kg / Cum And Fixing With Necessary Stainless Steel Ball Bearing Hinges Of Size 100X89x3mm Of Approved Make, Including Applying A Coat Of Approved Fire Resistant Primer Or Powder Coating Not Less Than 30 Micron Etc All Complete As Per Direction Of Engineer-In-Charge ( Panelling To Be Paid For Seperately ) . 58 Providing And Fixing Glazing In Fire Resistant Door Shutters, Fixed Panels & Partitions Etc., With G.I. Beading Made Out Of 1.6 Mm Thick G.I. Sheet ( Zinc Coating Not Less Than 120 Gm / M² ) Of Size 20 X 33 Mm Screwed With M4 X 38 Mm Ss Screws At Distance 75 Mm From The Edges And 150 Mm C / C , Including Applying A Coat Of Approved Fire Resistant Primer / Powder Coating Of Not Less Than 30 Micron On G.I. Beading, & Special Ceramic Tape Of 5 X 20 Mm Size Etc Complete In All Respect As Per Nbc 2016, Is 16231 ( Part 3 ) :2016 And As Per Direction Of Engineer-In-Charge With Glass Of Required Thickness Having 120 Minutes Of Fire Resistance Both Integrity & Radiation Control ( Ew120 ) And Minimum 20 Minutes Of Insulation ( Ei20 ) . The Manufacturer Have To Give Test Report / Certification Of Fire Glass And The Glass Should Have The Stamp Showing The Value Of E, Ew & Ei. The Glass Shall Be Tested In Approved Nabl Accredited Lab Or By Any Other Accreditation Body Which Operates In Accordance With Iso / Iec 17011 And Accredits Labs As Per Iso / Iec 17025 For Testing And Calibration Scopes Shall Be Eligible. The Maximum Glazing Size Shall Not Be More Than 1100X2200 Mm ( W X H ) Or 2.42 Sqm. 59 Providing And Fixing Panic Bar / Latch ( Double Point ) Fitted With A Single Body, Trim Latch & Lock On Back Side Of The Panic Latch Of Reputed Brand And Manufacture To Be Approved By The Engineer- In- Charge, All Complete. 60 Providing & Fixing Glass Panes With Putty And Glazing Clips In Wooden Doors, Windows, Clerestory Windows, All Complete With : 61 5.0 Mm Thick Glass Panes ( Weights Not Less Than 12.50 Kg / Sqm ) 62 Providing And Fixing Factory Made Upvc White Colour Sliding Glazed Window Upto 1.50 M In Height Dimension Comprising Of Upvc Multi-Chambered Frame With In-Built Roller Track And Sash Extruded Profiles Duly Reinforced With 1.60 ± 0.2 Mm Thick Galvanized Mild Steel Section Made From Roll Forming Process Of Required Length ( Shape & Size According To Upvc Profile ) , Appropriate Dimension Of Upvc Extruded Glazing Beads And Upvc Extruded Interlocks, Epdm Gasket, Wool Pile, Zinc Alloy ( White Powder Coated ) Touch Locks With Hook, Zinc Alloy Body With Single Nylon Rollers ( Weight Bearing Capacity To Be 40 Kg ) , G.I Fasteners 100 X 8 Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Including Drilling Of Holes For Fixing HardwareS And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approved Quality, All Complete As Per Approved Drawing & Direction Of Engineer-In-Charge. ( Single / Double Glass Panes, Wire Mesh And Silicon Sealent Shall Be Paid Separately ) . Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made.Note: For Upvc Frame And Sash Extruded Profiles Minus 5% Tolerance In Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable. 63 Two Track Two Panels Sliding Window Made Of ( Small Series ) Frame 52 X 44 Mm &Sash 32 X 60 Mm Both Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension. ( Area Of Window Upto 1.75 Sqm ) 64 Three Track Three Panels Sliding Window With Fly Proof Ss Wire Mesh ( Two Nos. Glazed & One No. Wire Mesh Panels ) Made Of ( Small Series ) Frame 92 X 44 Mm & Sash 32 X 60 Mm Both Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension ( Area Of Window Upto 1.75 Sqm ) . 65 Three Track Three Panels Sliding Window With Fly Proof S.S Wire Mesh ( Two Nos. Glazed & One No. Wire Mesh Panels ) Made Of ( Big Series ) Frame 116 X 45 Mm & Sash 46 X 62 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. ( Area Of Window Above 1.75 Sqm ) . 66 Providing And Fixing Factory Made Upvc White Colour Sliding Glazed Door Comprising Of Upvc Multi-Chambered Frame With In-Built Roller Track And Sash Extruded Profiles Duly Reinforced With 1.60 ± 0.2 Mm Thick Galvanized Mild Steel Section Made From Roll Forming Process Of Required Length ( Shape & Size According To Upvc Profile ) , Appropriate Dimension Upvc Extruded Glazing Beads, Upvc Extruded Interlock And Upvc Extruded Inline Sash Adaptor ( If Required ) , Epdm Gasket, Wool Pile, Zinc Alloy ( White Powder Coated ) Handle With Key On One Side Of Extreme Panels Along With Zinc Plated Mild Steel Multi Point Locking Having Transmission Gear With Keeps, Zinc Alloy ( White Powder Coated ) Cresent Lock ( If Required ) , Stainless Steel ( Ss 304 Grade ) Body With Adjustable Doublenylon Rollers ( Weight Bearing Capacity To Be 120 Kg ) , G.I Fasteners 100 X 8 Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Including Drilling Of Holes For Fixing HardwareS And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approved Quality, All Complete As Per Approved Drawing & Direction Of Engineer-In-Charge. ( Single / Double Glass Panes, Wire Mesh And Silicon Sealent Shall Be Paid Separately ) . Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made.Note: For Upvc Frame And Sash Extruded Profiles Minus 5% Tolerance In Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable. 67 Two Track Two Panels Sliding Door Made Of ( Big Series ) Frame 67 X 50 Mm & Sash 46 X 82 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. ( Area Of Door Above 2.00 Sqm Upto 5.00 Sqm ) 68 Providing And Fixing Stainless Steel ( Grade 304 ) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature ( Wherever Required ) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I / C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-Incharge, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc. ) . 69 Providing And Fixing Carbon Steel Galvanised ( Minimum Coating 5 Micron ) Dash Fastener Of 10 Mm Dia Double Threaded 6.8 Grade ( Yield Strength 480 N / Mm2 ) , Counter Sunk Head, Comprising Of 10 M Dia Polyamide Pa 6 Grade Sleeve, Including Drilling Of Hole In Frame , Concrete / Masonry, Etc. As Per Direction Of Engineer-In-Charge. 70 10 X 80 Mm 71 10 X 140 Mm 72 Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. 73 In Stringers, Treads, Landings Etc. Of Stair Cases, Including Use Of Chequered Plate Wherever Required, All Complete 74 In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 75 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 76 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm ( Thickness To Be Specified By The Manufacturer ) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3 Kg / Sqm Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. 77 Providing And Laying Polished Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm ( Average ) Thick Base Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge. 78 Polished Granite Stone Slab 79 Granite Stone Slab 18 Mm Thick In Risers Of Steps, Skirting, And Cladding Laid On 12 Mm ( Average ) Thick Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete. 80 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3 Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. 81 Size Of Tile 600X600 Mm 82 Providing And Laying Vitrified Tiles In Different Sizes ( Thickness To Be Specified By Manufacturer ) , With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Dado, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3 Kg / Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. 83 Size Of Tile 600X600 Mm 84 Extra For Pre Finished Nosing To Treads Of Steps Of Marble Stone. 85 Extra For Marble Stone Flooring In Treads Of Steps And Risers Using Single Length Up To 2.00 Metre. 86 Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 87 40 Mm Thick With 20 Mm Nominal Size Stone Aggregate 88 Cement Plaster Skirting Up To 30 Cm Height, With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) , Finished With A Floating Coat Of Neat Cement. 89 18 Mm Thick 90 Engineered Wooden Flooring : Panel 1820 X 145 Total Thickness 14 Mm Numbers Of Panels Per Pack 6 Nested Lengths Max. 1 Plank Out Of 6 M2 Per Pack 1, 583 M2 Kg Per Pack 11, 99 Kg Toplayer Pefc Controlled Sources En 13489 ± 3 Mm Core Board Pefc Controlled Sources Spruce Backing Layer Pefc Controlled Sources Wood Veneer 2 Mm Tongue And Groove Length Uniclic Width Uniclic Multifit Domestic Use Conditions In Each Pack 33 Years Uniclic - Multifit Connection Lifetime Commercial On Request Wood For Life Edge Protect+ Provides A Warranty On Build-Up Of Residue Dirt Along The Edges Due To Maintenance Over The Years 10 Years 91 Wood For Life Surface & Edge Protect + ( Lacquered Products Only ) Provides A Warranty On Pollution Of Surface Structure And A Warranty On Build-Up Residue Dirt Along The Edges Due To Maintenance Over The Years 10 Years Surface Layer Wood Species Oak Origin Europe Finishing Uv Cured Oiled Finish 2 Layers Uv Cured Lacquer Anti-Scratch Top Coat 5 - 7 Layers Natural Variance Due To Nature, Visual Surface Can Deviate From Samples Surface Treatments Cf Catalogue / Website Nature Marquant Vibrant General Aspect Of Installed En 13489 Lipping - Difference In Height ( Mm ) = 0, 20 Difference In Width ( Mm ) = 0, 20 Cupping Lengthwise % = 0, 1 Cupping In Width % = 0, 2 Dimensional Stability Iso 24339 Cupping Short Side Max % = 0, 30 Changes 30 - 85 % Rh Cupping Short Side Min % = - 0, 20 Open Joints Short Side ( Mm ) = 0, 20 Open Joints Long Side ( Mm ) = 0, 30 Underfloor Heating Suitable Of Special Installation Instructions. 92 Providing And Fixing Heat Resistant Terrace Tiles ( 300 Mm X 300 Mm X 20 Mm ) With Sri ( Solar Refractive Index ) > 78, Solar Reflection > 0.70 And Initial Emittance > 0.75 On Waterproof And Sloped Surface Of Terrace, Laid On 20 Mm Thick Cement Sand Mortar In The Ratio Of 1:4 ( 1 Cement : 4 Coarse Sand ) And Grouting The Joints With Mix Of White Cement & Marble Powder In Ratio Of 1:1, Including Rubbing And Polishing Of The Surface Upto 3 Cuts Complete, Including Providing Skirting Upto 150 Mm Height Along The Parapet Walls In The Same Manner 93 Providing And Fixing Plain Lining With Necessary Screws / Nuts & Bolts / Nails, Including A Coat Of Approved Primer On One Face, And Fixed On Wooden / Steel Frame Work, Complete As Per Direction Of Engineer-In Charge ( Frame Work Shall Be Paid For Separately ) . 94 12Mm Thick Commercial Ply Conforming To Is : 1328 Bwr Type 95 Providing And Fixing Specified Wood Frame Work Consisting Of Battens 50X25mm Fixed With Rawl Plug And Drilling Necessary Holes For Rawl Plug Etc. Including Priming Coat Complete. 96 Kiln Seasoned And Chemically Treated Hollock Wood 97 Providing And Fixing Partition Upto Ceiling Height Consisting Of G.I. Frame And Required Board, Including Providing And Fixing Of Frame Work Made Of Special Section Power Pressed / Roll Form G.I. Sheet With Zinc Coating Of 120 Gms / Sqm ( Both Side Inclusive ) , Consisting Of Floor And Ceiling Channel 50Mm Wide Having Equal Flanges Of 32 Mm And 0.50 Mm Thick, Fixed To The Floor And Ceiling At The Spacing Of 610 Mm Centre To Centre With Dash Fastener Of 12.5 Mm Dia Meter 50 Mm Length Or Suitable Anchor Fastener Or Metal Screws With Nylon Plugs And The Studs 48 Mm Wide Having One Flange Of 34 Mm And Other Flange 36 Mm And 0.50 Mm Thick Fixed Vertically Within Flanges Of Floor And Ceiling Channel And Placed At A Spacing Of 610 Mm Centre To Centre By 6 Mm Dia Bolts And Nuts, Including Fixing Of Studs Along Both Ends Of Partition Fixed Flush To Wall With Suitable Anchor Fastener Or Metal Screws With Nylon Plugs At Spacing Of 450 Mm Centre To Centre, And Fixing Of Boards To Both Side Of Frame Work By 25 Mm Long Dry Wall Screws On Studs, Floor And Ceiling Channels At The Spacing Of 300 Mm Centre To Centre. The Boards Are To Be Fixed To The Frame Work With Joints Staggered To Avoid Through Cracks, M.S. Fixing Channel Of 99 Mm Width ( 0.9 Mm Thick Having Two Flanges Of 9.5 Mm Each ) To Be Provided At The Horizontal Joints Of Two Boards, Fixed To The Studs Using Metal To Metal Flat Head Screws, Including Jointing And Finishing To A Flush Finish With Recommended Jointing Compound, Jointing Tape, Angle Beads At Corners ( 25 Mm X 25 Mm X 0.5 Mm ) , Joint Finisher And Two Coats Of Primer Suitable For Board As Per ManufactureS Specification And Direction Of Engineer In Charge All Complete. 98 75 Mm Overall Thickness Partition With 12.5 Mm Thick Double Skin Fire Rated Glass Reinforced Gypsum ( Grg ) Plaster Board Conforming To Is: 2095: Part 3 ( Board With Bis Certification Marks ) 99 Providing And Fixing Thermal Insulation With Resin Bonded Fibre Glass Wool Conforming To Is: 8183 Having Density 24 Kg / M3, 50 Mm Thick, Wrapped In 200G Virgin Polythene Bags Fixed To Wall With Screw, Rawel Plug & Washers And Held In Position By Criss Crossing Gi Wire Etc. Complete As Per Directions Of Engineer-In-Charge. 100 Carpet Tiles: Providing And Laying Carpet Tiles Of Yarn Type Eco Solution Q® Nylon ( Nylon 6 ) Only; Multi-Level Pattern Loop, Manufactured Using 100% Solution Dyeing Process, Tiles Of Size 23Cms X 91Cms Or Equivalent As Per Direction Of Eic And Site Requirement With Ssp® Soil Protection Treatment Tm Or Equivalent Containing Properties Of Stain Repel, With Ecoworx® Tile- 100% Pvc Free / 100% Bitumen Free / 100% Recyclable - Backing System With Recycled Content, Made From Thermoplastic Polyolefin Compound With Reinforcing Layer High-Performance Environments Requiring Modular Flooring, Having Tufted Yarn Weight Of 542.5 Gsm / Sqm And Average Yarn Density Of Minimum 9143 Oz / Cu. Yd. Or More, Nominal Total Thickness 5.42 Mm Minimum, Radiant Panel Class 1 Rated ( Astm E648 ) , Nbs Smoke < 450, Pill Test -Passed, Anti Static Property Less Than 3.5 Kv, Texture Appearance Retention Rating Of 3.5 For Severe Use, Anti Microbial Treatment-Passes ( Aatcc-174 ) . Cri Green Label Plus Is Certified For Indoor Air Quality, Including Fixing / Installation With Low / Zero Voc Content Adhesive. Impact Sound ( Iso 10140-3 ) 20 Db & Sound Absorption ( Iso 354 ) 0.2 Class D.Or Equilent As Per Direction Of Eic And Site Requirement 101 Supply And Installation Of 100Mm Cliq Aluminium ( Grade 6063 ) Skirting With 15 Micron Anodising In Natural Finish. Thickness 1.30 To 1.50Mm. Designed To Conceal Screws. Seamless Finish. Complete With Rubber / Pvc Jointers And Gasket. 102 Providing Gola 75X75 Mm In Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10 Mm And Down Gauge ) , Including Finishing With Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand ) As Per Standard Design : 103 In 75X75 Mm Deep Chase 104 Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size ) Over P.V.C. Sheet 1 M X1 M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand ) And A Coat Of Neat Cement, Rounding The Edges And Making And Finishing The Outlet Complete. 105 Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms / Sqm ( Both Side Inclusive ) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I.Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall / Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C / C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per ManufacturerS Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : 106 12.5 Mm Thick Tapered Edge Gypsum Plain Board Conforming To Is: 2095- ( Part I ) :2011 ( Board With Bis Certification Marks ) 107 Providing And Fixing Mineral Fibre False Ceiling Tiles At All Heights Of Size 595X595mm Of Approved Texture, Design And Pattern. The Tiles Should Have Humidity Resistance ( Rh ) Of 99%, Light Reflectance ? 85%, Thermal Conductivity K = 0.052 - 0.057 W / M K, Fire Performance As Per ( Bs 476 Pt - 6 &7 ) In True Horizontal Level Suspended On Interlocking T-Grid Of Hot Dipped All Round Galvanized Iron Section Of 0.33 Mm Thick ( Galvanized @120 Gsm ) Comprising Of Main T Runners Of 15X32 Mm Of Length 3000 Mm, Cross T Of Size 15X32mm Of Length 1200 Mm And Secondary Intermediate Cross T Of Size 15X32 Mm Of Length 600 Mm To Form Grid Module Of Size 600X600 Mm Suspended From Ceiling Using Galvanized Mild Steel Item ( Galvanised@80Gsm ) 50 Mm Long 8Mm Outer Diameter M-6 Dash Fasteners, 6 Mm Diameter Fully Threaded Hanger Rod Up To 1000 Mm Length And L-Shape Level Adjuster Of Size 85X25x2 Mm, Spaced At 1200 Mm Centre To Centre Along Main ‘T’. The System Should Rest On Periphery Walls / Partitions With The Help Of Gi Perimeter Wall Angle Of Size24x24x3000 Mm Made Of 0.40 Mm Thick Sheet, To Be Fixed To The Wall With Help Of Plastic Rawl Plug At 450 Mm Centre To Centre & 40 Mm Long Dry Wall S.S. Screws. The Exposed Bottom Portion Of All T-Sections Used In False Ceiling Support System Shall Be Pre-Painted With Polyester Baked Paint, For All Heights. The Work Shall Be Carried Out As Per Specifications, Drawings And As Per Directions Of The Engineer-In-Charge. 108 With 20 Mm Thick Beveled Tegular Mineral Fibre False Ceiling Tile ( Nrc 0.7 ) 109 12 Mm Cement Plaster Of Mix : 110 1:6 ( 1 Cement : 6 Coarse Sand ) 111 6 Mm Cement Plaster Of Mix: 112 1:3 ( 1 Cement : 3 Fine Sand ) 113 18 Mm Cement Plaster In Two Coats Under Layer 12 Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand ) Finished With A Top Layer 6 Mm Thick Cement Plaster 1:6 ( 1 Cement : 6 Fine Sand ) . 114 Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. 115 Wall Painting With Premium Acrylic Emulsion Paint Of Interior Grade, Having Voc ( Volatile Organic Compound ) Content Less Than 50 Grams / Litre Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour. 116 Two Coats 117 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade 118 Two Or More Coats On New Work 119 Finishing Walls With Textured Exterior Paint Of Required Shade : 120 New Work ( Two Or More Coats Applied @ 3.28 Ltr / 10 Sqm ) Over And Including Priming Coat Of Exterior Primer Applied @ 2.20Kg / 10 Sqm 121 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 122 White Washing With Lime To Give An Even Shade : 123 New Work ( Three Or More Coats ) 124 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) : 125 For Fixed Portion:Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) 126 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Costof Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) 127 Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) 128 Providing And Fixing Double Glazed Hermetically Sealed Glazing In Aluminium Windows, Ventilators And Partition Etc. With 6 Mm Thick Clear Float Glass Both Side, Having 12 Mm Air Gap, Including Providing Epdm Gasket, Perforated Aluminium Spacers, Desiccants, Sealant ( Both Primary And Secondary Sealant ) Etc. As Per Specifications, Drawings And Direction Of Engineer-In-Charge Complete. 129 Filling The Gap In Between Aluminium Frame & Adjacent Rcc / Brick / Stone Work By Providing Weather Silicon Sealant Over Backer Rod Of Approved Quality As Per Architectural Drawings And Direction Of Engineer-In-Charge Complete. 130 Upto 5Mm Depth And 5 Mm Width 131 Providing And Fixing 12Mm Thick Frameless Toughened Glass Door Shutter Of Approved Brand And Manufacture, Including Providing And Fixing Top & Bottom Pivot & Double Acting Hydraulic Floor Spring Type Fixing Arrangement And Making Necessary Holes Etc. For Fixing Required Door Fittings, All Complete As Per Direction Of Engineer In Charge ( Door Handle, Lock And Stopper Etc. To Be Paid Separately ) 132 Providing And Fixing Aluminium Tubular Handle Bar 32 Mm Outer Dia, 3.0 Mm Thick & 2100 Mm Long With Ss Screws Etc .Complete As Per Direction Of Engineer-In-Charge. 133 Powder Coated Minimum Thickness 50 Micron Aluminium Tubular Handle Bar 134 Providing And Fixing Toilet Cubicals With The Following Specificationsthickness Of Compact Laminate : 18 Mm Color Of Hpl Boards: As Approved By Engineer-In-Charge Size Of Cubicle : As Per Drawingdoor Size : 1995Mm ( H ) X 610Mm ( W ) Divider Size : 1995Mm ( H ) Overall Height Of Cubicle : 2100Mm ( Including Boom Gap Of 100Mm ) Accessories: Standard - Merino Make Stainless Steel - 304 Grade Accessories ) A ) Ss U Channel B ) Ss F Channel C ) Ss Coat Hook D ) Ss Privacy Thumb Turn C / W Occupancy Indicator E ) Ss Door Knob F ) Ss Hinges With Cover G ) Ss Shoe Box Leg 18Mm - 316 Grade H ) Rubber Lining For Groove I ) S.S.Screws 304 G & P .V.C Wall Plugs 135 Providing And Laying Water Proofing Treatment To Vertical And Horizontal Surfaces Of Depressed Portions Of W.C., Kitchen And The Like Consisting Of: ( I ) Ist Course Of Applying Cement Slurry @ 4.4 Kg / Sqm Mixed With Water Proofing Compound Conforming To Is 2645 In Recommended Proportions Including Rounding Off Junction Of Vertical And Horizontal Surface. ( Ii ) Iind Course Of 20 Mm Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand ) Mixed With Water Proofing Compound In Recommended Proportion Including Rounding Off Junction Of Vertical And Horizontal Surface. ( Iii ) Iiird Course Of Applying Blown Or Residual Bitumen Applied Hot At 1.7 Kg. Per Sqm Of Area. ( Iv ) Ivth Course Of 400 Micron Thick Pvc Sheet. ( Overlaps At Joints Of Pvc Sheet Should Be 100 Mm Wide And Pasted To Each Other With Bitumen @ 1.7 Kg / Sqm ) . 136 Providing And Laying Integral Cement Based Water Proofing Treatment Including Preparation Of Surface As Required For Treatment Of Roofs, Balconies, Terraces Etc, Consisting Of Following Operation:A ) Applying And Grouting A Slurry Coat Of Neat Cement Using 2.75 Kg / Sqm. Of Cementadmixed With Proprietary Water Proofing Compound Conforming To Is 2645 Over The Rcc Slab Including Cleaning The Surface Before Treatment.B ) Laying Cement Concrete Using Broken Bricks / Brick Bats 25Mm To 100 Mm Size With 50% Cement Mortar 1:5 ( 1 Cement : 5 Coarse Sand ) Admixed With Proprietary Water Proofing Compound Conforming To Is : 2645 Over 20Mm Thick Layer Of Cement Mortar Of Mix 1:5 ( 1 Cement : 5 Coarse Sand ) Admixed With Proprietary Water Proofing Compound Conforming To Is : 2645 To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Of Junctions Of Walls And Slabs.C ) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Admixed With Proprietary Water Proofing Compound Conforming To Is : 2645.D ) Finishing The Surface With20mm Thick Joint Less Cement Mortar Of Mix 1:4 ( 1 Cement : 4 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Is : 2645 And Finally Finishing The Surface With Trowel With Neat Cement Slurry And Making Of 300X300 Mm Square.E ) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test. All Above Operation To Be Done In Order And As Directed And Specified By Engineer-In-Charge.With Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65 Mm. 137 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge. 138 Nominal Concrete 1:3:6 Or Richer Mix ( I / C Equivalent Design Mix ) 139 Nominal Concrete 1:4:8 Or Leaner Mix ( I / C Equivalent Design Mix ) 140 Demolishing R.C.C. Work Manually / By Mechanical Means Including Cutting Reinforcement Bars And Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer - In- Charge. 141 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. 142 In Cement Mortar 143 Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead :Of Area 3 Sq. Metres And Below 144 Dismantling Steel Work Riveted, Bolted Or Welded In Built Up Sections And Tubular Section Including Dismembering And Stacking Within 50 Metres Lead In: 145 Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm 146 Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres Lead. 147 Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved. 148 Repairs To Plaster Of Thickness 12 Mm To 20 Mm In Patches Of Area 2.5 Sq.Meters And Under, Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In-Charge.With Cement Mortar 1:4 ( 1Cement: 4 Coarse Sand )

Key Value

Document Fees
INR 5000 /-
EMD
INR 450620.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
c7707790-9c79-4145-ac4f-044bfa594be2.html Tender Notice 0 KB
BOQ_212974.xls Tender Document 0 KB
FINPROPREPSUNDER.pdf Tender Document 0 KB
REPSUNDER.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: “Special Repair & Maintenance work of Institution for Children with Special Abilities (Girls) at Sundernagar, District Mandi, Himachal Pradesh”
Sl. No. Item Description
1Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing :
21:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
31:3:6 (1 cement : 3 coarse sand derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
4Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.
5All works above plinth level upto floor V level
6Concrete of M25 grade with minimum cement content of 330 kg /cum
7Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete. Above plinth level.
8Thermo-Mechanically Treated bars
9Centering and shuttering including strutting, propping etc. and removal of form for :
10Suspended floors, roofs, landings, balconies, and access platform
11Lintels, beams, plinth beams, girders, bressumers and cantilevers
12Columns, Pillars, Piers, Abutments, Posts and Struts
13Extra for shuttering in circular work (20% of respective centering and shuttering items)
14Shelves
15Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
16Edges of slabs and breaks in floors and walls
17Under 20 cm wide
18Weather shade, Chajjas, corbels etc., including edges
19Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
20Stairs, (excluding landings) except spiral-staircases
21Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).
22Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
23Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
24Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
25Cement mortar 1:6 (1 cement : 6 coarse sand)
26Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
27Cement mortar 1:4 (1 cement :4 coarse sand)
28Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
29Providing and filling AAC blocks including proper watering and compaction in sunken areas all complete as per drawings and as directed by the Engineer-in-chargein-Charge.
30Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, edge moulding, facia and polishing to edges to give high gloss finish etc. complete at all levels.
31Granite of any colour and shade
32Area of slab upto 0.50 sqm
33Area of slab over 0.50 sum.
34Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
35Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.
36Granite Stone of approved shade
37Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
38Second class teak wood
39Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
4035 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
41Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
42Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured):
43Rectangular or square
44Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
45250x10 mm
46100x10 mm
47Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge.
48200mm
49Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge.
50Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete
51Twin rubber stopper
52Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
53Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
54Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.
551.5 mm thick
56Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/ sqm) suitable for mounting 120 minutes Fire Rated Glazed Door Shutters. The frame shall be filled with mineral wool Insulation having density minimum 96Kg/cum. The frame will have a provision of G.I. anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with factory made template for SS ball bearing hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- Charge . (Cost of SS ball bearing hinges is excluded).
57Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minutes fire rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/sqm) duly filled mineral wool insulation having density minimum 96 kg/cum and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-Charge (panelling to be paid for seperately).
58Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm.
59Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.
60Providing & fixing glass panes with putty and glazing clips in wooden doors, windows, clerestory windows, all complete with :
615.0 mm thick glass panes (weights not less than 12.50 kg/ sqm)
62Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.
63Two track two panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm)
64Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm).
65Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm).
66Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable doublenylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.
67Two track two panels sliding door made of (big series) frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm)
68Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
69Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.
7010 x 80 mm
7110 x 140 mm
72Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
73In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
74In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
75Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
76Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
77Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
78Polished Granite stone slab
79Granite stone slab 18 mm thick in risers of steps, skirting,and Cladding laid on 12 mm (average) thick cement mortar 1:3(1 cement : 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete.
80Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
81Size of Tile 600x600 mm
82Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, dado, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.
83Size of Tile 600x600 mm
84Extra for pre finished nosing to treads of steps of marble stone.
85Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre.
86Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
8740 mm thick with 20 mm nominal size stone aggregate
88Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.
8918 mm thick
90ENGINEERED WOODEN FLOORING : Panel 1820 x 145 Total thickness 14 mm Numbers of panels per pack 6 Nested Lengths Max. 1 plank out of 6 m2 per pack 1,583 m2 Kg per pack 11,99 kg Toplayer PEFC controlled sources EN 13489 ± 3 mm Core board PEFC controlled sources Spruce Backing layer PEFC controlled sources Wood Veneer 2 mm Tongue and groove Length Uniclic Width Uniclic Multifit Domestic use Conditions in each pack 33 years Uniclic - Multifit connection Lifetime Commercial On request "Wood for Life" Edge Protect+ Provides a warranty on build-up of residue dirt along the edges due to maintenance over the years 10 years
91"Wood for Life" Surface & Edge Protect + (lacquered products only) Provides a warranty on pollution of surface structure and a warranty on build-up residue dirt along the edges due to maintenance over the years 10 years Surface layer Wood species Oak Origin Europe Finishing UV cured Oiled finish 2 layers UV cured Lacquer Anti-scratch top coat 5 - 7 layers Natural variance Due to nature, visual surface can deviate from samples Surface treatments cf catalogue/website Nature Marquant Vibrant General aspect of installed EN 13489 Lipping - difference in height (mm) = 0,20 difference in width (mm) = 0,20 cupping lengthwise % = 0,1 cupping in width % = 0,2 Dimensional stability ISO 24339 Cupping short side max % = 0,30 Changes 30 - 85 % RH Cupping short side min % = - 0,20 Open joints short side (mm) = 0,20 Open joints long side (mm) = 0,30 Underfloor heating Suitable of special installation instructions.
92Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner
93Providing and fixing plain lining with necessary screws/nuts & bolts/ nails, including a coat of approved primer on one face, and fixed on wooden /steel frame work, complete as per direction of Engineer-in charge (Frame work shall be paid for separately).
9412mm thick commercial ply conforming to IS : 1328 BWR type
95Providing and fixing specified wood frame work consisting of battens 50x25mm fixed with rawl plug and drilling necessary holes for rawl plug etc. including priming coat complete.
96Kiln seasoned and chemically treated hollock wood
97Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture"s specification and direction of engineer in charge all complete.
9875 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG) plaster board conforming to IS: 2095: part 3 (Board with BIS certification marks)
99Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183 having density 24 kg/m3, 50 mm thick, wrapped in 200G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in-Charge.
100CARPET TILES: Providing and laying Carpet tiles of Yarn type Eco Solution Q® Nylon (Nylon 6) only; Multi-Level Pattern Loop, manufactured using 100% solution dyeing process, Tiles of size 23cms x 91cms or equivalent as per direction of EIC and site requirement with SSP® Soil Protection treatment TM or equivalent containing properties of Stain Repel, with Ecoworx® Tile- 100% PVC Free/ 100% Bitumen Free/ 100% Recyclable - backing system with recycled content, made from thermoplastic polyolefin compound with reinforcing layer high-performance environments requiring modular flooring, having tufted yarn weight of 542.5 gsm/sqm and average yarn density of Minimum 9143 oz/cu. yd. or more, Nominal total thickness 5.42 mm minimum, Radiant Panel class 1 rated (ASTM E648), NBS smoke < 450, Pill test -Passed, Anti Static Property less Than 3.5 kv, Texture Appearance Retention Rating of 3.5 for Severe Use, Anti Microbial Treatment-Passes (AATCC-174). CRI Green Label Plus is certified for indoor air quality, including fixing/ installation with Low/ Zero VOC content Adhesive. Impact Sound (ISO 10140-3) 20 dB & Sound absorption (ISO 354) 0.2 Class D.or equilent as per direction of EIC and site requirement
101Supply and installation of 100mm CliQ Aluminium (Grade 6063) Skirting with 15 micron anodising In Natural Finish. Thickness 1.30 to 1.50mm. Designed to conceal screws. Seamless finish. Complete with Rubber/ PVC Jointers and Gasket.
102Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
103In 75x75 mm deep chase
104Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
105Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I.wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
10612.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
107Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ? 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.
108With 20 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.7)
10912 mm cement plaster of mix :
1101:6 (1 cement : 6 coarse sand)
1116 mm cement plaster of mix:
1121:3 (1 cement : 3 fine sand)
11318 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
114Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
115Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
116Two coats
117Painting with synthetic enamel paint of approved brand and manufacture to give an even shade
118Two or more coats on new work
119Finishing walls with textured exterior paint of required shade :
120New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
121Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
122White washing with lime to give an even shade :
123New work (three or more coats)
124Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
125For fixed portion: Powder coated aluminium (minimum thickness of powder coating 50 micron)
126For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
127Powder coated aluminium (minimum thickness of powder coating 50 micron)
128Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.
129Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
130Upto 5mm depth and 5 mm width
131Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge (Door handle, lock and stopper etc. to be paid separately)
132Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge.
133Powder coated minimum thickness 50 micron aluminium tubular handle bar
134Providing and fixing Toilet cubicals with the following specifications Thickness of Compact Laminate : 18 mm Color of HPL Boards: As approved by Engineer-in-charge Size of Cubicle : As per drawing Door Size : 1995mm (H) x 610mm (W) Divider Size : 1995mm (H) Overall Height Of Cubicle : 2100mm (Including boom Gap of 100mm) Accessories: Standard - Merino Make Stainless Steel - 304 Grade accessories) a) SS "U" Channel b) SS "F" channel c) SS Coat Hook d) SS Privacy Thumb turn c/w Occupancy Indicator e) SS Door Knob f) SS Hinges with Cover g) SS Shoe Box Leg 18mm - 316 Grade h) Rubber Lining for Groove i) S.S.Screws 304 G & P .V.C Wall Plugs
135Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i)Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
136Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc, consisting of following operation: a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm. of cementadmixed with proprietary water proofing compound conforming to IS 2645 over the RCC slab including cleaning the surface before treatment. b) Laying cement concrete using broken bricks / brick bats 25mm to 100 mm size with 50% cement mortar 1:5 (1 cement : 5 coarse sand) admixed with proprietary water proofing compound conforming to IS : 2645 over 20mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) admixed with proprietary water proofing compound conforming to IS : 2645 to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. c) After two days of proper curing applying a second coat of cement slurry admixed with proprietary water proofing compound conforming to IS : 2645. d) Finishing the surface with20mm thick joint less cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and finally finishing the surface with trowel with neat cement slurry and making of 300x300 mm square. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operation to be done in order and as directed and specified by Engineer-in-charge. With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
137Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
138Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
139Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
140Demolishing R.C.C. work manually/ by mechanical means including cutting reinforcement bars and stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
141Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
142In cement mortar
143Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below
144Dismantling steel work riveted, bolted or welded in built up sections and tubular section including dismembering and stacking within 50 metres lead in:
145Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
146Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
147Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
148Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1cement: 4 coarse sand)
Disclaimer :