Tender For Essential Changing Of Broken Asbestos Sheet With Galvalume Sheet, Dismantling Broken Gypsum False Ceiling With New False Ceiling, Inside And Outside Repairing, Painting Of Tetra Bts Body Guard Lines, Kolkata During The Year 2023-2024 ., Kolkata-West Bengal

Police Department-PD has published Tender For Essential Changing Of Broken Asbestos Sheet With Galvalume Sheet, Dismantling Broken Gypsum False Ceiling With New False Ceiling, Inside And Outside Repairing, Painting Of Tetra Bts Body Guard Lines, Kolkata During The Year 2023-2024 .. Submission Date for this Tender is 07-03-2024. Dismantling Work Tenders in Kolkata West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

42466816
Tender For Essential Changing Of Broken Asbestos Sheet With Galvalume Sheet, Dismantling Broken Gypsum False Ceiling With New False Ceiling, Inside And Outside Repairing, Painting Of Tetra Bts Body Guard Lines, Kolkata During The Year 2023-2024 .
Open Tender
Indian
West Bengal
Kolkata
07-03-2024

Tender Details

Essential Changing Of Broken Asbestos Sheet With Galvalume Sheet, Dismantling Broken Gypsum False Ceiling With New False Ceiling, Inside And Outside Repairing, Painting Of Tetra Bts Body Guard Lines, Kolkata During The Year 2023-2024 .

Key Value

Document Fees
Refer document
EMD
INR 7000.0 /-
Tender Value
INR 3.48 Lakhs /-

BOQ Items

Name of Work: e-Tender for Essential changing of broken asbestos sheet with galvalume sheet, dismantling broken gypsum false ceiling with new false ceiling, inside and outside repairing, painting of Tetra BTS Body Guard Lines, Kolkata during year 2023-2024
Sl. No. Item Description
1Essential changing of broken asbestos sheet with galvalume sheet, dismantling broken gypsum false ceiling with new false ceiling, inside and outside repairing, painting of Tetra BTS Body Guard Lines, Kolkata during year 2023-2024
2Taking out carefully G.C.I. or C.I. or asbestos sheets (including ridges etc.) from roof or wall after unscrewing bolts, nuts, screws etc.and stacking the material at site as directed.
3Supplying, fitting, fixing bolts with nuts, washer:(i)10 to 16 mm dia:(a)Length up to 75 mm
4Supplying , fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap.(i) In Roof:-a) With 0.5 mm thick sheet
5(B) Dressed wood work in post , plate , battens . etc. fitted & fixed complete (excluding the cost of bolts only, but including the cost of nails, screws etc.)(ii) Sal : Local.
6Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge.
7Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid T 2430/1510 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 4 mm thick High Pressure Steam Cured Non Asbestos Fibre Cement Standard Ceiling Board (Density > 1500 Kg/m3) of size 595 mm X 595 mm, conforming IS 14862 & Type A Category IV of ISO 8336, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge.a) False Ceiling (with 4mm thick Pearl Designer Fibre Cement Board and E-Grid T-2430/1510).
8Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including round off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/stagingwhere necessary (Ground floor).(ii) With 1:4 cement mortar (a) 20 mm thick plaster
9Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finishacrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer"s specification and as per direction of the EIC.In Ground Floor:(a) One Coat
10Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer"s specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost ofprimer.In Ground floor (Two Coat)c) Super Protective100% Acrylic Emulsion.
11Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paintincluding scraping and preparing the surface throughly, complete as per manufacturer"s specification and as per direction of the EIC. (In Ground Floor)(a) One Coatii)Solvent based interior grade Acrylic Primer
12Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damaes complete. (Concrete and brick work for mending damage will be paid separately)(b) Above area 2.5 Sq.m
13Panel (made of single plank) of door and window shutters to design as directed: In Ground Floor (Payment to be made on area of exposed new work). (In case of non-supply of single plank penal rate of reduction to a maximum of 30% will be made)(i) 12mm Thick panel of 30cm to 45cm width(a) Ordinary Teak Wood
14Styles and rails of wooden shutters fitted and fixed complete. (Payment to be made on area of new work only). In Ground Floor:(iii) 37.5mm. Thick shutter (a) Ordinary Teak Wood.
15Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.(viii) 100mm. X 75mm. X 3.50mm
16Anodised aluminium skeleton bolt of approved quality manufactured from extruded section conforming to I.S: specification (I.S: 204/74) fitted and fixed with cadmiim plated screws:(iv) 300mm long x 12mm dia. bolt.
17Supplying solid flush type doors of deluxe decorative (both side) quality, conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings in ground floor:(a) 35mm thick shutters (single leaf)
18Acrylic Distemperto interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer"s specification) including cleaning and smoothning of surface. Two Coats
19(a) Priming one coat on timber or plasteredsurface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
20(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary:(a) On timber or plastered surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)
21Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed.
22Removing old scales, blisters etc. of interior surface of walls,ceiling by scraping etc. and preparing smooth and even surface with rendering or cement mortar (1:2) (as necessary), to make the surface suitable for receiving distemper. (Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge).
23Rendering the Surface of walls and ceiling with White Cement base water proof wall putty of approved make & brand.(1.5 mm thick)
24Sub Total
25GST 18%
26LWC 1%
Disclaimer :