Tender For Beautification Of Gandhi Ganj Area Second Call; 1 Beautification Of Gandhi Ganj Area 2 Surface Excavation N.Exc ( Not Exceeding ) 30 Cmdeep And Averaging 15Cmdeep And Getting Out Soft / Loose Soil Surface Dressing Road 3 Rough Excavation Notexceeding 1.5 M Deep Andgetting Out Soft / Loose Soil F1 4 Cement Concretein Foundations, Filling And Massconcrete Type D21:4:8 ( 40 Mm Graded Aggregate ) Pcc F1 5 Treating The Bottom And Sides Of Excavationat The Rate Of 5 Litres Of Emulsion Per Squaremetre Of Surface Area M&L 6 Moorum / Red Bajri Filling In Floors Orpavings, Laid In Layers N Exc. 15 Cmthick, Spread, Levelled And Rammedincluding Watering 7 Foundations, Includingrafts, Footings, Foundationbeams; Plinth Beams; Basesfor Columns, Etc.; Basementslabs, Under-Reamed Pilesand Mass Concrete M 20–Grade Concrete Rcc F1 C1 Plinth Beam At 0.00 Lvl 8 Formwork To Sides Of Concretefoundations, Footings, Bases Ofcolumns, Raft And Raft Beams, Sides And Soffits ( If Any ) Offoundation And Plinth Beams;And Similar Work; Vertical Or Tobatter Rough Finished Surfaces Of Concrete F1 C1 9 Formwork To Faces Of Walls, Retaining Walls, Abutments, Parapets And Staircase Railingsand Similar Work Includingattached Pillasters, Buttresses, Etc.; Vertical Or To Batter Plinth Beam At 0.00 Lvl 10 Mild Steel Bars 10Mmdia And Over, Cut Tolength, Bent To Shaperequired, Includingcranking, Bendingspirally For Hoopingfor Columns, Hookingends And Bindingwith And Includingmild Steel Wire ( Annealed ) Not Lessthan 0.9Mm Dia Orsecuring With Clips Thermo-Mechanically Treated Bars. ( Tmt ) 80 Kg Per Cum 11 Ditto, But 6Mm To8mm Dia. 12 Rendering 10Mm Thickon Fair Faces Of Brickwork Or Concrete Surfaces 12Mm Thick Cement Plaster 1:6 ( 1 Cement: 6 Sand ) Same As Shuttering 13 Priming Plastered Andother Surfaces With Alkaliresistantpriming Paintm&L Sum Of Plaster 14 Distempering Walls Withdistemper Dry, White Ortinted 1St Coat Subsequent Coat Painting On Nearly Building 15 Steel Work In Tubular Trussesincluding Special Shapedwasher Etc. Complete Usingerw Or Induction Butt Weldedtubes Conforming To I. S.1161-1979 Grade St.-240 16 Surfaces Of Anydescription, Over10cm In Width Orgirth, Not Otherwisedescribed Synthetic Enamel ( Ordinary Tint ) Low Height Railing 17 Machine Pressed Precastconcrete Interlocking Paverblock Any Shape And Sizeconfirming To Is 15658-2006Of 80 Mm Thickness M-40Grade Paver Block 18 Stone Kerb Of Roughly Squaredstones Of Size 20Cm X 30Cm, Dressed So That The Maximumdepression From A Straightedge Held Against The Dressedsurface Shall Not Exceed 6Mmfor Top And Exposed Surfacesof Sides And 20Mm For The Restof Surfaces Jointed In Cementmortar 1:6 And Struck Flushm&L 19 Providing And Fixing Rectangular Hollow Box Size:- 450Mm Ht. And 250Mmx250mm ( 2Mm Thick Sheet Having Lockable Weather Proof Flush Door Junction Box Complete Erected In An Approved Manner ) Steel Work Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete With Cnc Cutting Design As Per Architectural Drawing With Proper Arrangment Of Electrical Light And Steel Specification 20 Construction Of Base Platform Of Concrete , Size- 2’X2’X2’ ( Ht.Above G.Level ) ( Approx. ) With Foundation In Ground I / C Providing Bolts For Fixing / Erecting Electric Pole , Complete. 21 Providing & Laying Copper Cable ( 1.5 Sq.Mm. ) In P.V.C. 1” Dia. Casing Pipe In Provided Trenches Lane And Providing Copper Cable ( 1.5 Sq.Mm. ) Up To Ht. Of Pole And Connectingto Lamps Complete. 22 Trenching Of Ground Up To 1’Depth ( Max. ) And 1’Width ( Max. ) I / C Laying Of Provided Casing Pipeup To Distance About 30Feet ( Approx. ) From Pole To Pole And Filling The Trench And Leveling The Ground Complete Job. 23 Supply And Installation Of Stainless Steel Bollard Material: Stainless Steelheight Of Pole: 900 Mmdiameter Of Pole: 114 Mmthickness Of Pipe: 2 Mm 24 Supply And Fixing Of Multi Core Round Frlsh Pvc Insulatedcopper ( Flexible ) Conductor & Pvc Sheathed Cables 1100Voltsas Per Is:694-1990 Of Approved Make ( 24 / 0.2 Mm ) Three Core0.75 Sq.Mm. 25 Providing And Fixing 4.0Mm ( 8 Swg ) Dia G.I. Wire On Surface Or In Recessed For Loop Earthing As Required 26 Supply Of Xlpe Insulatedpower Cable ( Confirming Is-7098 Part-I ) 1100 Volt Grade, 1 Core / 2 Core / 3½ Core / 4 Core Isi Marked With Alu. Stranded / Solid Conductor2 Core Armoured16 Sq.Mm. 27 Supplying And Fixing Heavy Duty Cable Gland For P.V.C. Insulated Armored Cable With Brass Washer, Rubber Ring Complete Erected With Cable And Lead Connection Etc. As Per Specification Complete. Gland Size 22Mm Suitable For Cable 2 / 3, 3½, 2 / 4 X 10 Sq.Mm Or 2X 16 Sq.Mm 28 Supplying And Fixing Cramping Type Alum. Lugs As Per I.S.S. Specification Suitable For Following Size Of Cable With Alu. / Copper Solid / Stranded Conductor Evently Cramped With High / Pressure Tool And Connected To Switch Gear / Bus / M.C.C.B. / M.C.B. Etc. As Required Complete. For Conductor Size-6Mm To 16 Sq.Mm 29 Supplying & Fixing Pin Terminal Lugs As Per Iss Specification Suitable For Cable Evenly Cramped With High Pressure Tool & Connection To Switch Gear Terminal. Aluminum Lugs Pin Type Up To 16 Sq.Mm2 Conductor Size 30 Suppying & Installing G.I. Pipe For Protection Of Underground Cable Fixed On Wall / Support / In Trench / Fixed Between Two Rigid Existing Support Of Wall / Beam For Erection Of Ceiling Fan / Down Rod For Stiff Pendent For Light Luminaries / Fan / Protective For Earthing, Lightening Conductor Down Strip / Overhead Service Line / For Submersible Cable Or Centrifugal Pump For Water Supply With Necessary Iron Clamp Coupler, Bend, Tee, Elbow, Nuts And Bolts Etc. Complete In An Approved Manner As Required To Complete Excluding Cost Of Excavation / Dismentalling & Other Finshed Masonary Item Complete. A Class G.I.Pipe Isi Marked ( Is-1161-69 ) 100.00Mm 31 Supplying And Installing Double Wall Corrugated Pipes ( Dwc ) Of Hdpe ( Is 14930 Part Ii -Marked ) For Cable Laid Under Ground With Necessary Material And At Required Depth Upto 90Cm. Below Road / Ground Surface, Including Excavation, Back Filling With Excavated Material, Ramming And Making The Surface Good. 90.00Mm Outside Dia. 32 Laying Of One Number Armoured / Unarmoured Power Cable 1:1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc Hume / Stone Ware / G.I. Pipe / Surface In Existing Trench As Required. 33 Laying Of One Number Armoured / Unarmoured Cable 1.1Kv Grade Of Size Not Exceeding 25 Sq.Mm On Wall / Truss With Approved Type Of Iron Clamps Etc. As Required. 34 Supply & Fixing Of Decorative Led Street Light Of 1 To 3 Watt Witheach , System Lumens Output With Efficacy>=135Lm / W ( @6500K ) , ItSbody Made Of Die Cast Aluminium Using Pressure Die-Casting Process.Hole For Coupling On Pipes Ø 60 Mm, For Lateral Installation. Silicongasket Enusures The Ip Protection. Ip Rating - Ip66. Power Ledmodule With High Efficacy LedS On Single Printed Circuit Boardwith Metal Core Plate. Colour Rendering Index: Ra > 70. Electronicpower Supply For Led Module, Which Offers Protection Against Shortcircuit, Over- Voltage & Over- Current, With In-Built Surgeprotection Upto 4Kv ( An Additional Surge Protection Device Of 10Kvalso Provided In-Built The Fixture ) . Pf >0.95 And Thd<10%. Lenscover In Pc ( Ik09 ) . Estimated Led Lifetime Is L70 @ 1, 00, 000Hours Minimum. Lm79-80 Report From Led Manufaturer Should Besubmitted. Safety Test Report As Per Iec 60598-2-3; Iec 60598-1 / Is10322 Iec 61347 I / C Connection Wire , Testing Etc-Supporting Testreport From Nabl Approved Lab, With 5 Year On Site Warranty. 35 Supplying, Fixing, Testing & Commissioning Wall / Floor Mountedlt Panel Primer Coated With Powder Coated Paint & Provided With Required Gasket For Dust / Vermin Proof With Degree Of Protection Ip42 Suitable For 415V 3 Phase, 50 Hz, 4 Wire Systemfabricated Out Of Crca Sheet Upto 2 Mm Thick ( 1.6 Mm For Doors ) Duly Compartmentalised For Incomer, Bus Section, Outgoings, Cable Alleys & Ct, Pt Ampere Meter, Volt Meter, Selector Switches, Frequency Meter, Phase Indicating Lamps, Energy Meter Complete Including Cost Of Busbar Supports, Detachable Cable Gland Plates, 2 Earthing Terminals, Internal Wiring & Fixing Of Separately Supplied Mcbs, Mccbs , Acb, Panel Mounted Changeover Switch / Sfus, Etc. As Required But Excluding Cost Of Busbar Strips, Ampere Meter, Volt Meter, Selector Switch As Per Approved Design & Specification 36 Supplying And Fixing Of Lt Panel Accessories Of Approved Make In Existing Lt Panel Including Connections Etc.As Required As Per Specification Aluminium Bus Bar Strips With Pvc Sleeves 37 Supplying Of Isi Marked And Accepted Standard Of Miniature Circuit Breaker ( Mcb ) Of C Series Suitable For240 / 415 Volts, 50 Cycle , 10 Ka Valueac Supply Confirming To Is : 8828 : 1996, Iec : 60898 :2002 But Without Enclosures :- Double Pole ( Dp ) 50 Amp To 63 Amp Rating 38 Supplying & Fixing Time Switch 39 Providing And Fixing Of Bakelite Sheet 10Mm Thick, One Mcb 6A - 32A Sp & Suitable Upto 16Sq.Mm Cable Stud Type 4 Way Epoxy Connector For Decorative Designer Poles / Octagonal Pole Box. 40 Dismantling Of Brick Work Built In Cement Motar 41 Dismantling Of Stone Slabs And Tiles Of Any Description Or Thickness In Floors, Aprons Etc. 42 Dismantling Of Asbestos Cement ( Corrugated / Semi Corrugated Etc. ) Sheets In Roof Covering 43 Dismantling Of Rafter Purling Etc 44 Dismantling Of Wrought Iron Or Mild Steel Work Of Any Description Not Otherwise Provided For