Tender For Provision Of Certain Sanction Works Under Ge Gangtok, Gangtok-Sikkim

Military Engineer Services-MES has published Tender For Provision Of Certain Sanction Works Under Ge Gangtok. Submission Date for this Tender is 05-02-2024. Dismantling Work Tenders in Gangtok Sikkim. Bidders can get complete Tender details and download the document.




Tender Notice

40930324
Corrigendum : Tender For Provision Of Certain Sanction Works Under Ge Gangtok
Open Tender
Indian
Sikkim
Gangtok
05-02-2024

Tender Details

Tender For Provision Of Certain Sanction Works Under Ge Gangtok; 1 Dismantling Of Plain Or Corrugated Steel Sheeting , Any Gauge, Thickness, Including Nainital Or Similar Pattern Roof Covering. 2 Demolition Of Cement Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided For Complete All As Specified And Directed. 3 Dismantling Wrought Iron Or Mild Steel Work Of Any Description Not Otherwise Provided For. 4 Taking Up Or Down 50Mm Bore Steel Water Tubings And Fittings Etc Complete And Makinggood Disturbed Surfaces Of Walls / Ceilings Etc Complete All As Specified And As Directed. 5 Taking Up Or Down 25Mm Bore Steel Water Tubings And Fittings Etc Complete And Makinggood Disturbed Surfaces Of Walls / Ceilings Etc Complete All As Specified And As Directed. 6 Taking Up Or Down 15Mm Bore Steel Water Tubings And Fittings Etc Complete And Makinggood Disturbed Surfaces Of Walls / Ceilings Etc Complete All As Specified And As Directed. 7 Taking Up Or Down 20Mm Bore Steel Water Tubings And Fittings Etc Complete And Makinggood Disturbed Surfaces Of Walls / Ceilings Etc Complete All As Specified And As Directed. 8 Fixing Only 50Mm Bore Of Tube, Any Grade, To Walls And Ceilings Or Laying In Floors Complete All As Specified And Directed. 9 Fixing Only 25Mm Bore Of Tube, Any Grade, To Walls And Ceilings Or Laying In Floors Complete All As Specified And Directed. 10 Fixing Only 15Mm Bore Of Tube, Any Grade, To Walls And Ceilings Or Laying In Floors Complete All As Specified And Directed. 11 Fixing Only 20Mm Bore Of Tube, Any Grade, To Walls And Ceilings Or Laying In Floors Complete All As Specified And Directed. 12 M&L For 50Mm Bore Steel Tubing Medium Grade, Galvanised Fitting Fixed Complete To Walls And Ceiling Or Floor Complete. 13 M&L For 25Mm Bore Steel Tubing Medium Grade, Galvanised Fitting Fixed Complete To Walls And Ceiling Or Floor Complete . 14 M&L For 15Mm Bore Steel Tubing Medium Grade, Galvanised Fitting Fixed Complete To Walls And Ceiling Or Floor Complete . 15 M&L For 20Mm Bore Steel Tubing Medium Grade, Galvanised Fitting Fixed Complete To Walls And Ceiling Or Floor Complete For This Following. 16 Taking Down Cement Plaster Of Any Description On Brick Or Stone Walls Incl Raking Out Joints Hacking For Key, Scrubing Down With Water Etc Complete All As Specified And Directed. 17 Demolition Ofreinforcedconcrete Of Any Description And In Any Position Not Otherwise Specifically Provided For . 18 Demolition Of Precast Concrete Block Walling / Brick Wall Built In Cement Mortar 19 M&L For Pre Cast Cement Concrete Block Masonry With Solid Blocks, Exc. 10 Cm In Width And Setttingin Cement Mortar 1:6 Type C1 1:3:6 ( 20 Mm Graded Aggregate ) Complete. 20 M&L For Rendering 15Mm Thick In Cement Mortar 1:4 Inusing Wpc In Finishing Layer On Brick Or Concrete Surfaces Finished Even & Smooth Without Using Extra Cement Complete All As Specified And Directed. ( Note:-Wpc For Finishing Layer Will Be Paid Seperately As Supply Only ) . 21 M&L For Rendering 15Mm Thick On Fair Faces Of Brick Or Concrete Surfaces In Cement Mortar ( 1:6 ) Finished Even & Smooth Without Using Extra Cement Complete All As Specified And Directed. 22 M&L For Rendering 5Mm Thick In Cement Mortar ( 1:3 ) On Brick Or Concrete Surfaces In Ceilings, Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. 23 Liquid Waterproofing Compound 24 M &Lfor Rcc 1:2:4 Type B-1 ( Using 20Mm Graded Stone Aggregate ) As In Slabs Supported On Wallsincluding Necessary Form Work Complete All As Specified & As Directed.Note:Re-Inforcement Shall Be Measured And Paid Separately. 25 M&L For Pcc ( 1:2:4 ) , Type B-1 ( Using 20Mm Graded Stone Aggregate ) As In Copingcomplete All As Specified & As Directed. 26 Dismantling Water Tanks 5000 Ltrs Capacitycomplete All As Specifiedand Directed. 27 Disconnecting Existing Tanks, Setting Aside ( Or Lowering If Required ) For Repairs, Cleaning, Etc. And Hoisting If Required Reconnecting And Re-Fixing In Position. ( Cleaning Repairing, Etc. Measured Separately ) Complete All As Specified And Directed 28 S&F Rotational Moulded Polythene Water Storage Tanks ( Cylindrical Vertical With Closed Top ) Hoisted And Fixed In Postion ( Cylindrical Vertical With Closed Top ) Hoisted And Fixed In Postion 5000 Ltrs Capacity Complete All As Specified And Directed 29 S&F In Repairs Gun-Metal, Globe Or Gate Valves, With Iron Wheel Head, Screwed Both Ends For 25Mm Bore Gi Pipe All Complete As Specified And As Directed 30 S&F In Repairs 25Mm Ball Brass Valves, High Pressure, With Polythene Float And Flynut Complete, Screwed For Iron Pipe Or Brass Ferrule And Fixed Complete As Specified And As Directed 31 S&F Rolled Section As In Main And Cross Beams Hip, Jack Rafters, Hollow Section Purlins, Where Connected To Common Rafters And Running Rails And Guides For Sliddinng Doors Fixed With Angle Cleats Or Other Connecting Plates Of Grade Fe-410, Complete All As Specifed & Directed. 32 M&L For Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer To Steel Surfaces Of Any Description Over 10 Cm In Width Or Girth Incl Preparation Of New Steel Surfaces Complete All As Specifed And Directed. 33 S&F As In Repair 110 Mm Bore Pvc ( Swr ) Pipes Single Socketed, In Any Length With Rubber Ring Joints Fixed To Wall, Laid In Trenches Or In Floor With All Necessary Clamps, Bolts, Bends, Tee Etc Complete All As Specified And As Directed. 34 S&F As In Repair 110 Mm Bore Pvc ( Swr ) Bends Any Radiuscomplete All As Specified And Directed. 35 M&L For Providing Cement Concrete 1:2:4 Type B-1 ( Using 20Mm Graded Stone Aggregate ) As In Roof Padding / Roof Kerb To Bring Top Surface Of Slab In Slope Complete All As Specified And Directed. 36 M&L For 15 Mm Thick Cement Screed In Cement Mortar 1:3 Admixed With Approved Integral Water Proofing Compound As Per ManufactererS Instructions. ( Note:- Fosroc Complastx 412 Ic @ 130 Ml Per Bag Cement Incl A Bonding Coat Of FosrocSnitco Bond Ar Cement Slurry Or Shalimar Tar Product, Mumbai No 1 Liquid@ 200 Ml Per Bag Or Any Equivalent Approved Make Of Products ) 37 M&L For Applying One Coat Of Industrial Bitumen 85 / 25@1.2Kg / Sqm Over Applying Primer Bitumen Coat @ 0.30Kg / Sqm Including Cleaning Surfaces Complete All As Specified And Directed. 38 M&L App Based Polymeric Membrane Minium Weighing 3Kg / Sqm And Minium 3 Mm Thick Reinforced With Polyster Non Wove Fabric ( Wt Not Less Than 150 Gms / Sqm ) Laid On Primed Surface By Forced Application Complete All As Specified. 39 M&L For Plain Cement Concrete ( 1:2:4 ) , Type B2 ( Using 40 Mm Graded Stone Aggregates ) In Walls Or Retaining Walls, Any Thickness, Size Or Shape Including Pilasters, Buttresses Columns, Pillars, Boundary Pillars And Posts ( Including Caps And Bases ) , Complete All As Specified And Directed. 40 Surface Excavation N Exc. ( Not Exceeding ) 30 Cm Deep And Averaging 15Cm Deep And Getting Out Soft / Loose Soil, All As Specified And As Directed. 41 Rough Excavation Not Exceeding 1.5 M Deep And Getting Out In Soft / Loose Soil, All As Specified And Directed. 42 Excavating In Trenches, N Exc 1.5 M Wide And N Exc 1.5 M In Depth; For Foundation, Laying Of Underground Cables Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Under Groung Cables Etc. N Exc 10 Sq M On Plan And N Exc 1.5 M In Depth And Getting Out In Soft / Loose Soil, Complete All As Specified And Directed. 43 Returning Filling In Soft / Loose Soil Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exceeding 25Cm, Complete All As Specified And Directed. 44 Removal Of Surplus Excavated Soils To A Distance Not Exceeding 50M And Depositing Where Directed At A Level Not Exceeding 1.50M Above The Starting Point, Complete All As Specified And Directed. 45 M&L For Plain Cement Concrete ( 1:4:8 ) , Type D2 ( Using 40 Mm Graded Stone Aggregates ) As In Foundation, Filling And Mass Concrete, Complete All As Specified And Directed. 46 M&L For Hardcore Using Broken Stone Or Boulders Of Gauge N Exc. 63Mm, Deposited, Spread And Levelled In Layers N Exc. 15 Cm Thick, Watered And Rammed To A True Surface, Complete All As Specified And Directed. 47 M&L For Stone Walling Of Random Rubble, Uncoursed, Well Bonded, Bedded And Solidly Hearted, Built In Cement Mortar ( 1:6 ) Including Brought Up To Courses Complete All As Specified & As Directed. 48 M&Lfor 100 Mm Thickcement Concrete 1:3:6Type B-2 ( Using 40 Mm Graded Stone Aggregate ) As Inhardstanding / Flooring / Path Etc And Finishing The Surface Even And Fair Etccomplete All As Specified And Directed. 49 M&L For Lacquer Coated Precast Chequred Cement Concrete Tiles Made With Grey Cement And Pigment Of Size 300 X 300 X 25 Mm Thick As In Pavement / Footpath, Set And Jointed In Neat Cement Slurry And Pointed With Cement Laid Over Laid Over And Including Screed Bed / Bedding Layer Of 15Mm Thick In Cemnt Mortar ( 1:4 ) Compelte All As Directed. 50 S&F For Pvc ( Swr ) 75Mm Pipes Single Socketed, In Any Length With Rubber Ring Joints, Laid In Trenches Or In Floor With Necessary Clamps, Bolt, Bends, Tee All As Specified And Directed. 51 M&L For Pcc ( 1:3:6 ) , Type C-1 ( Using 20Mm Graded Stone Aggregate ) As In Copingcomplete All As Specified & As Directed. 52 M&L For Rendering 15 Mm Thick In Cm ( 1:4 ) On Other Than Fair Faces Of Stone Masonry, Finished Even & Fair With Using Extra Cement Complete All As Specified And Directed. 53 M&L For Pre-Cast Cement Concrete Block Masonry With Solid Blocks, Type C1 1:3:6 ( 20Mm Graded Aggregate ) Exc 10Cm In Width And Setting In Mortar 1:6, Complete All As Specified And Directed. 54 S&F 5 To 6Mm Thick Pvc Wall / Ceiling Panels Of Interlocking Types, Width 250 / 255 Mm With Lamination Design And Exc 60% Of Pvc Content Including Necessary H-Joints, Internal / External Corner Trim, Coner Cove, F / J Edge Trims Where Required Fixed With Hidden Screws To Steel / Woodenframe Work Complete All As Specified And As Directed. 55 M&L For Applying Two Coats Of White Wash On Old Plastered Wallsurfaceincluding Preparation And Previously Untreatedsurfaces Ofceiling Allcomplete All As Specified And Directed . 56 M&L For Precast Pcc 1:3:6 Type C1 ( By Using 20Mm Graded Stone Aggregate ) Block Masonry With Solid Blocks, Exc 10 Cm In Width And Setting In Cm 1:6 Complete All As Specified And As Directed. 57 M&L For Formwork To Sides Of Concrete Foundation, Footings, Bases Of Columns, Raft And Raft Beams, Sides & Soffits ( If Any ) Foundation And Plinth Beam, Retaining Wall For Rough Finished Surfaces Of Concrete Complete All As Specifed & Directed. 58 M&L Rcc ( Nominal Mix ) Type B1, 1:2:4 Using 20Mm Graded Stone Aggr As In Foundations, Including Rafts, Footings, Foundation Beams; Plinth Beams; Bases For Columns, Etc.; Basement Slabs, Under-Reamed Piles And Mass Concrete Complete All As Specified And As Directed 59 M&L Forpre-Cast Rcc 1:2:4 Type B-1 ( Using 20Mm Graded Stone Aggregate ) As In Manholes Covers Etc Including Necessary Form Work And Set In Cm 1:4 Complete All As Specified And Directed.Note:Re-Inforcement Shall Be Measured And Paid Separately. 60 M&L For Formworks To Sides And Soffit Of Floor, Roof Beam, Beam Haunching, Girders, Bressummers, Lintels, Cantiliver Shelves Including Support Overhangs Etc Also Splays Between Floor And Beam Etc Complete All Specifed And Directed 61 M&L For Rcc 1:2:4 ( Nominal Mix ) 20Mm Graded Aggregate As Inbeams, Cantilevers, Bressumers, Lintels Over 1.5Mspan Complete All As Specifed And Directed. 62 M&L For 75Mm Thick Pcc Type C-2 ( 1:3:6 ) Using 40 Mm Graded Agg In Plinth Protection Path / Hardstanding Finished Cement Concrete Surfaces Fair And Even Including Forming Construction Joint Filled With Cm ( 1:6 ) All As Specified & Directed. 63 M&L Rendering 15Mm Thick In Cm 1:6 On Other Than Fair Faces Of Brick Or Concrete Surfacescomplete All As Specified And Directed. 64 M&L For Rendering 15 Mm Thick In Cm ( 1:4 ) In Two Layers Of 10Mm And 5Mm ( Outer Layer Cm Should Be Added With Liquid Wpc ) On Fair Faces Of Brick Or Concrete Surfaces, Complete All As Specified And Directed. ( Note:-Wpc For Finishing Layer Will Be Paid Seperately As Supply Only ) . 65 Supply Only Liquid Water Proofing Compound. 66 M&L For Non- Skid Ceramic Plain Coloured Tiles 7 To 8 Mm Thick ( Square / Rectangular ) Conforming To Is 13712 Grade B-Ii ( A ) , Approved Make And Colour Shade, Area Of Each Tile Exc 0.11 Sqm But Not Exc 0.18 Sqm , In Floors Etc Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Matchover & Including Screed Bed Or Bedding Layer 15 Mm Thick In Cm 1:4 Complete All As Specified & As Dirceted. 67 M&Lfor Glazed Ceramiccolouredtilesof Size Not Less Than 350X250x7mm / 450X300x7mm Mm Thick Fixed On Vertical Surfaces Such As Dado / Skirting, Raiser To Steps Etc Conforming To Is - 13712 Grade Ib-Iii Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match, Over And Including Screed Bed / Backing Layer Of 10 Mm Thick In Cement Mortar ( 1;3 ) Complete All As Specified & As Dirceted. 68 S&F Rotational Moulded Polythene Water Storage Tanks ( Cylindrical Vertical With Closed Top ) Hoisted And Fixed In Postion ( Cylindrical Vertical With Closed Top ) Hoisted And Fixed In Postion 500 Ltrs Capacity Complete All As Specified And Directed 69 S&F For 15 Mm Bore Angular Stop Cocks Fancy Type, Chromium Plated Reduce Body Screwed Down High Pressure Screwed Both Ends For Iron Pipe Or For Union Etc As In Repair. 70 S&F Bib Taps 15Mm Bore Fancy Type Chromium Plated With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule And Fixed Complete All As Specified And Directed. 71 S&F Ball Valve Brass 20 Mm Dia High Pressure With Polythene Float And Fly Nut Complete Secrewed For Iron Pipe Or Brass Ferrule Etc All As Specified. 72 S&F Gun-Metal, Globe Or Gate Valves, With Iron Wheel Head, Screwed Both Ends For 20Mm Bore Gi Pipe All Complete As Specified And As Directed 73 S&F For 15 Mm Bore Pillar Taps Of Ptmtany Colour High Pressure Screwed For Iron Pipe And Fixed ( Minimum Weight 15Mm- 110Gms ) All Complete As Specified And As Directed 74 M&L For Plain Cement Concrete ( 1:3:6 ) , Type C2 ( Using 40 Mm Graded Stone Aggregates ) In Walls Or Retaining Walls, Any Thickness, Size Or Shape Including Pilasters, Buttresses Columns, Pillars, Boundary Pillars And Posts ( Including Caps And Bases ) , Complete All As Specified And Directed. 75 Labour Only For Hand Packing Using Broken Stone Or Boulders ( Any Thickness ) At Back Of Retaining Walls Over Arches Etc. And Raising Or Lowering To The Required Level Complete All As Specified And Directed. 76 S&F Solid Pvc Door Frame Of Size 50Mm X 47Mm Made Out Of 5Mm Plain Colourpvc Sheet Reinforced With Ms Square Tubesupplying & Fixing In Opening As Per Specification And Drawing Complete All As Specified And Directed. 77 S&F Of 30Mm Thick ( Style Thickness ) Factory Made Solid Panel Pvc Door Shutter Consisting Of Frame Made Out Of Mild Steel Tubes For Top And Bottom Rails, Ild Steel Frame Shall Be Covered With Heat Moulded Single Side Prelam Pvc C Channel Having A Pvc Sheet Strip Of 20Mm Width Stuck Inside With Solvent Cement For Stiles And Single Side Prelam Pvc Sheet For Top Rail, Lock Rail And Bottom Rail On Either Side & As Gap Insert For Top Rail And Bottom Rail On Either Side & As Gap Insert For Toprail And Bottom Rail, Panelling Of Both Side Prelam Pvc Sheet To Be Fitted In The Mild Steel Frame Welded / Sealed To The Stiles And Rails With Uitable Pvc Sheet Beading And Jointed Together With Solvent Cement As Per Specification And Drawing Given On Mes Schedule Part-Ii ( 2020 ) Complete All As Pecified And Directed. 78 S&F Aluminum Window And Ventilator Shutters, Fixed Type Without Sash Bar, Aluminum Sectionweighing 0.55 Kg / M Including Necessary Joining Cleats, Galzing Clips, 4Mm Thick Glass / Ac Board / Particle Board Rubber Neoprene Packing Incl Aluminum Grill And Anodised Aluminium Snap Beading Screws Etc.Complete All As Specified And Directed. 79 M&L For Applyingtwo Coat Of White Washing Including Preparation Of New Or Previously Untreated Surface Of Ceiling Complete All As Specified And Directed. 80 M&L For Applying Two Coats Of Exterior Acrylic Emulsion Painting Over A Coat Of Alkali Resistant Primer Including Scaffolding Upto 15M Ht Andpreperation Of Old / Newsurfaces All As Directed 81 Excavation In Post Holes In Soft / Loose Soil Or Similar Holes Each N Exc 0.5 Cum Getting Out Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25 Cm And Remaning Surplus Soil Removing To A Distance N Exc 50Cm And Making Good Surface, Complete All As Specified And Directed. 82 M&L For 150 Mm Size Aluminium Anodised Cast Type Handles. 83 S&F Of 150Mm Long Aluminium Anodised, Barrel Tower Bolt Of Extruded Section. 84 S&F Of 75Mm Size Mild Steel Butt Hinges Medium Weight. 85 S&F For 200 Mm Long Aluminium Anodised Sliding Door Boltwith Hasp, Staple ( Bolt Type ) And Fixing Clips Of Sheet, Cast Or Extruded Section And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast Aluminium Complete All As Specified And Directed. 86 S&F Vitreous China Squatting Pan Of‘Orissa Pattern’, Size 580 Mm X 440Mm ( White ) With ‘P’ Or ‘S’ Trap, Front Or Back Inlet And Foot Rests, Any Pattern Complete Including Provision Of Pcc Bedding Andconnection To Trap, And To Flushing Pipe, Antisyphonage Pipe, Etc. Complete Including Making Good To Floorcomplete All As Specified & As Dirceted. 87 S&Fvitreous China, Wash Hand Basin, White, Flat Backof Size 550 Mm X 400 Mm, Including Cutting For And Pinning In Ends Of Brackets Or Errecting Stands And 15 Mm Bore Pvc Connector Pipe, 32 Mm Dia Chromium Plated Waste Coupling, 32 Mm Dia Pvc Waste Pipe Complete All As Specified & As Dirceted. 88 S&F Pvc ( Swr ) Floor Trap 75Mm, Plain With Grating Including Jointing With Solvent Cement Complete All As Specified & As Dirceted. 89 S&F 10 Litre Capacity Low Level Pvc Flushing Cistern ( Any Colour ) , Syphonic Action Type, With Inlet, Ball Valve, Float, Handle, Fixed With Cast Iron Bracket ( Of Suitable Size ) And Providing 32 Mm Dia Pvc Flush Pipe And Making All Necessary Connections Complete ( Excluding Pvc Connection Pipe ) Complete All As Specified & As Dirceted.Make : Cera, Cat No B1010107, Parry Ware , Hindware Orequivalent. 90 S&F Pvc Connections 15 Mm Size With Ptmt Nuts Of Length 600Mm Complete All Asspecified And Directed. Make: Prayag Cat No 323 Or Equivalent. 91 M&L For Pcc 1:3:6 Type C-2 ( By Using 40 Mm Graded Stone Aggregate ) As In Bed To Drain Pipes 150 Mm Bore, Including Packing Under And Haunching Against The Sides Of Pipesafter They Are Laid And Tested, Complete All As Specified And Directed. 92 S&F 150 Mm Bore Pvc ( Swr ) Pipes Single Socketed, In Any Length With Rubber Ring Joints Fixed To Wall, Laid In Trenches Or In Floor With Necessary Clamps, Bolts, Bends, Teeetc.Complete All As Specified And As Directed. 93 S&F Fitting Forpvc ( Swr ) Pipes Of75mm Bore As Pvc ( Swr ) Junction Double, ( Double T ) , Equal Or Unequal Provided With Access Door Complete All As Specified And As Directed. 94 S&F Fitting Forpvc ( Swr ) Pipes Of110mm Bore As Pvc ( Swr ) Junction Double, ( Double T ) , Equal Or Unequal Provided With Access Door Complete All As Specified And As Directed. 95 M&L For 100Mm Thick Pcc 1:2:4 Type B2 ( Using 40Mm Graded Stone Aggregate ) As In Sub-Base Of Floor, Path, Hardstanding, Floor Etc. Completeall As Specified And As Directed. 96 S&F For 600 X 450Mm Looking Mirror With Aluminium Channel Frame, Mounted On 6Mm Thick Commercial Plywood Frame And Fixed To Wooden Plug With Chromium Plated Brass Screws & Cup Washers Incl Glass Self Assembly Consisting Of 5.5 Mm Thick Sheet Glass Shelf 12 Cm Wide With Chromium Plated Bracket Guard And Railling 60 Cm Long Complete All As Specified And Directed. 97 M&L Lacquer Coated Coloured Chequered Cement Concrete Tiles Not Less Than 300 X 300Mm X 25Mm Thick Set, Jointed And Pointed In Neat Slurry In Floors With Grey Cement And Pigments Over And Incl 15Mm Thick Screed Bed Or Bedding Layer Of Motar For Laying Floor Finishes In Cement Plaster 1:4 All As Specified And As Directed. 98 M&L For Cutting Into Existing Manholes For Connecting New Drains ( Internal Dia Pipe 150Mm ) , Making Good To Pipe And Rendering, Cutting Out Existing Benching For And Forming Branch Channel ( 1 / 2 Round Or 3 / 4 Section ) In Cement Concrete 1:2:4 Type B-I Smooth Finished, And Reforming Benching All As Specified And Directed. 99 S&F For0.50Mm Thick Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheets Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Coveringfixed With Self Tapping Screws As In Roofcovering Complete All As Specified And Directed. 100 S&F For 0.50Mm Thick Pre-Painted Galvalume Aluminium Zinc Coating Gi Basedplain Steel Sheets Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Coveringfixed With Self Tapping Screws As In Roofcomplete All As Specified And Directed. 101 S&F For Harrison Rail, Mild Steel, Chromium Plated , 25 Mm Dia With Fixing Brackets, Stops, Rollers, Nob, Holder Etc In Curtain Rails Complete All Specified And Directed. 102 S&F Powder Coated Grid Frame Work For False Ceiling Comprising Of The Following Sections For Making Partitions Of 600 X 600M Size Fixed To Walls With Rawl Plugs & Screws And Hanged To Roof With And Including1mm Dia Gi Wire Suspender Of Suitable Length And Butterfly Clips, Size Of Main Tee Shall Be 28Mm X 23Mm X 0.30Mm Thick, Cross Tee Shall Be 24Mm X 23Mmx0.30Mm Thick And Wall Angle Shall Be 20Mm X 20Mm X 0.30Mm Thick Complete All As Specified And As Directed. 103 S&F For4mm Thick Non Asbestos Fibre Cement Building Board ( E-Board ) Of Approved Texture For Insulation And Acoustic Purpose Of Size 595X595 Mm Size Fixed With Staples On Snap Grid As In Ceiling With And Including Dusting Of Surface And Applying One Coats Of Oil Emulsion Distemper Over A Coat Of Primer Including Preparation Of Surfaces Complete All As Specified And Directed. 104 M&L For Dark / Light Shade Non Skid Tiles 8-10Mm Thick ( Square / Rectangular ) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqmin Floors Etc, Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match The Colourincl 20Mm Thick Screed Bed In Cement Mortar ( 1:6 ) For Laying Floor / Roof Finishes Complete All As Specifiedand Directed. 105 All As Per Item No 104Here-In-Above But In Skirting With 8-10 Mm Thick Backing Coat In Cm ( 1:4 ) Complete All As Specified And Directed. 106 M&L For Glazed Colouredceramic Tiles ( 350X250x7mm Thick / 450X300x7mm Thick ) On Vertical Surfaces Such As Skirting / Dado Set And Jointed In Neat Cement Slurry Pointed In White Or Coloured Cement To Match The Colour Incl 10 Mm Thick Screed Bed / Rendering Of Cm ( 1:4 ) As In Wallall As Specified And Directed. 107 M&L For 25 Mm Thick Pcc ( 1:2:4 ) Type B1 ( 20Mm Graded Stone Aggregate ) , Finished Concrete Surfaces Even Androughto Receive Floor Finishes Complete All As Specifiedand Directed. 108 M&L For Pre Cast Cement Concrete Block Masonry With Solid Blocks With 10 Cm In Width And Setttingin Cement Mortar 1:6 Type C1 1:3:6 ( 20 Mm Graded Aggregate ) Complete All As Specified And Directed. 109 M&L Forgranite ( Of Any Type ) Work 20 Mm Thick ( Table Rubbed And Polished ) In Steps, Jambs, Pillars, Window Cills, Cooking Platforms And Like In Cm 1:4 Including Pointing In White Cement ( 1:2 ) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite Granite Stone Including Cutting And Polishing Etc Including 20Mm Thick Screed Bed In Cm 1:6 Complete All As Specified And Directed 110 M&Lfor Rounding To Edges Of Graniteslabs One Edge Such As In Steps, Cooking Platforms And Other Similar Situations Complete All As Specified And Directed. 111 S&F Aluminum Door Shutters, Aluminum Section Weighing 0.55 Kg / M Including Necessary Joining Cleats, Galzing Clips, Rubber Neoprene Packing, 5Mm Thick Glass / Ac Board / Particle Board, Handles 02 Nos In Each Door Hinges Anodised Aluminium Snap Beading Screws Etc Xomplete All As Specified And Directed. 112 S&F Door Closer Of Aluminium ( Extruded Section ) Bodyhydraulically Regulateduniversal Type , Suitable For Door Shutters Of 701 To 850 Mm In Width And Of Weight Between 36Kgto60 Kg And Fixed. 113 S&F Aluminium Anodised, Aluminium Frame For Doors, Windows, Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc Complete All As Specified And Directed. 114 Fabrication And Fixing Powder Coated Aluminium Sliding ( Three Tracks ) / Openable / Fix Type Window / Ventilator / Partition Wall With Aluminium Frame Of Section 62.30 X 44.50 X 1.5 Mm With Shutter Stiles Rail Of Aluminum Section Of Size 47.62 X 44.45 X 1.5 Mm Thick Includiing Jointing Cleat For Fixing Binder Hardware Glazing Clips Rubber Packing For Air Lock Purpose Anodized Aluminium Strip Bearing Screw Etc For Fixing Glass Pans In Frame Shutter Covered With Fully Selected Quality Tinted Glass 4Mm Thick Tinted / Plain Glass With Rubber Packing And Locking Arrangement Complete All As Spcified And As Directed. 115 M&L For Use And Waste Of Form Work To Soffits Of Suspended Slab Such As Roof Slabs, Floor Slabs, Landing And Similar Works N. Exceeding 200Mm Thick For Flat Fair Finished Surfaces Of Conceter Complete All As Specified And As Directed. 116 M&L For Use And Waste Of Form Work To Edges Of Concrete Flats, Treads, Breaks In Flooors, Window Cills, Concrete Railings, Openings In Concrete Walls, Floor And Roofs Exc 10 Cm But N Exc 20Cm Wide Complete All As Specified And As Directed. 117 M &Lfor Rcc 1:2:4 Type B-1 ( Using 20Mm Graded Stone Aggregate ) As In Slabs Supported On Wallsincluding Necessary Form Work Complete All As Specified & As Directed.Note:Re-Inforcement Shall Be Measured And Paid Separately. 118 M&L For Tmt Bars , 10 Mm Dia And Over Cut To Length, Bent To Shape Required Including Cranking , Bending Spirally, Hooping For Columns, Hookings / Ends And Binding With And Including Ms Wire Not Less Than 0.9 Mm Dia Or Securing With Clips. 119 M&L 15 Mm Thick Rendering Plaster On Fair Faces Of Conc Faces In Cm 1:6 Complete All As Specified And As Directed. 120 M&L For Rendering 15Mm Thick In Cement Mortar 1:4 In Two Layers Of 10Mm And 5Mm ( Outer Layer Cm Should Be Added With Wpc ) In Finishing Layer On Brick Or Concrete Surfaces Finished Even & Smooth Without Using Extra Cement Complete All As Specified And As Directed. ( Note:-Wpc For Finishing Layer Will Be Paid Seperately As Supply Only ) . 121 M&L For Applying Two Coats Of Obd Over A Coat Of Primer Applied Over Providing And Applying Plaster Of Paris Putty Of Minimum 1 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Including Complete Removal Of Existing Treatment Andpreperation Of Old / New Surfaces Preparing The Surfaces Even And Smooth. 122 M&L For Applying Two Coats Of Exterior Acrylic Emulsion Painting Over A Coat Of Alkali Resistant Primer Including Complete Removal Of Existing Treatment Andpreperation Of Old / Newsurfaces Complete All As Specified And Directed. 123 S&F Half Round 150Mm Dia With Rounded Edges Including All Accessories / Fittings Like T , Y Etc For Eaves Gutter Complete All As Specified And Directed. 124 S&F Pvc ( Swr ) Bends Any Radius 110 Mm Dia Complete All As Specified And Directed. 125 M&L For 75Mm Thick Pcc Type C2 1:3:6 ( Using 40Mm Graded Stone Agg ) As Inplinth Protection / Path / Hardstandingfinished The Concrete Surfaces Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. 126 M&L For Plain Cement Concrete ( 1:3:6 ) , Type C-2 ( 40 Mm Graded Stone Aggregate ) In Surface Channels And Drains, Complete All As Specified And Directed. 127 M&L Lacquer Coated Coloured Chequered Cement Concrete Tiles Not Less Than 300 X 300Mm X 25Mm Thick Set, Jointed And Pointed In Neat Slurry In Floors And Steps With Grey Cement And Pigments Over And Incl 15Mm Thick Screed Bed Or Bedding Layer Of Motar For Laying Floor Finishes In Cement Plaster 1:6 All As Specified And As Directed. 128 Demolition Of Brickwork Or Stone / Boulder Masonry, Built In Cement Mortar Complete All As Dierceted. 129 Taking Down Chowkats Or Frames With Shutters ( Without Taking Off Shutters From The Frame ) Each Area Exc 1.5 Sqm Nut N.Exc 4Sqm All As Specified And As Directed. 130 Demolition To Cement Concrete In Ground Floors And Pavings Not Exc 15 Cm Thickness ( Below Or Above Ground Level ) Complete All As Specified And Directed. 131 M&L For Pre Cast Cement Concrete Block Masonry With Solid Blocks, Exc. 10 Cm In Width And Setttingin Cement Mortar 1:4 Type C1, ( 1:3:6 ) ( Using 20 Mm Graded Stone Aggregate ) As Per Is 383 Complete All As Specified And As Directed. 132 S&F2nd Class Flush Shutters 35Mm Thick, Solid Core Construction, With Block Board Core And Plywood Face Panels, Commercial Type On Both Sides Complete All As Spd And Direvcted . 133 M&L For Second Class Hard Wood Plain Solid Straight Chowkats And Frames Wrought Framed Rebated On The Solid Rounded On Chamfered Put Together With Glue Pinned And Joints. 134 Dismantling Of Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding ( But Not Backing ) And Removal Of Dismantled Materials / Rubbish From Site Complete All As Specified And Directed. 135 M&L For 25 Mm Thick Pcc ( 1:2:4 ) Type B-0 ( Using 12.5 Mm Graded Stone Aggregate ) As In Sub Base Of Floorcomplete All As Specified And As Directed. 136 S&Fvirified Ceramic Tiles 10 Mm Thick ( Square / Rectangular ) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over 15Mm Thick Screed Bed Or Bedding Layer In Cm ( 1:6 ) All As Spd And Directed. 137 Ditto All As Item No. 136 Above But On Vertical Surface Of Wall Like Skerting / Dado Etc On 15Mm Thick Rendering Complete. 138 M&L For Pcc 1:2:4Type B1 ( 20 Mm Gradede Aggregate ) As In Coping, Bed Plates , Parepet, Plinth Course Including Weathering, Slightly Rounded Or Chamfered Angles And Throating, All As Specified And As Directed. 139 M&L For Rcc Type B1 1:2:4 ( Using 20Mm Graded Stone Aggregate ) As In Foundations, Including Raft Footings, Foundation Beams; Plinth Beams; Bases For Columns, Lintel Beam, Cover Slabetc., Basement Slabs, Under Reamed Piles And Mass Concrete Incl Necessary Form Workcomplete All As Specified & As Directed.Note:Re-Inforcement Shall Be Measured And Paid Separately. 140 M&L For Ms Bars 5 Mm Dia And Over Upto And Including 10 Mm Dia In Stirrups Cut To Length, Bent To Shape Required Incl Cranking Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Incl Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Quality Conforming To Tmt Bars Complete All As Specified And Directed. 141 S&F Powder Coated Aluminium Door Shutters, Aluminium Section Weighing 0.55 Kg / M Including Necessary Joining Cleats, Glazing Clips, Ruber Neoprene Packing, Handles 2 Nos In Each Door, Hinges, Anodised Aluminum Snap Beading Screws Etc. Complete All As Specified 142 S&F Powder Coated Aluminium Frame For Doors, Windows, Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc, Complete All As Specified And Directed. 143 S&F5.5Mm Thick Sheet Glass, Ordinary Quality And Glazing With Oil Putty In Square N Exc 0.5 Sq. M In Each Pane Complete All As Specified And Directed. 144 S&F5mm Thick Plain Colour Pvc Sheet In Strips & Channel Feathered At The Edges For Fixing On Solid Pvc Wall Lining, Insulated Pvc Wall Lining, And Solid Pvc Partitions Inclusive Of Solvent Cement And Fixing At Site Complete All As Specified And Directed. 145 S&F Aluminium Body Door Closer Hydraulically Regulated, Designation No. 3, Universal Type, Suitable For Door Shutters Of 851To 1000 Mm In Width And Of Weight Between 61 To 80 Kg And Fixed Complete All As Specified And Directed. 146 S&F Safety Lever Locks Mild Steel With 4 Levers For Door Shutters Complete All As Speciofied And Directed. 147 M&L For Preparation Of Newplastered Surfaces Of Walls Applying Two Coats Of Distemper, Oil Emulsion, White Or Tinted Over Newwall Suface On A Coat Wall Care Putty 1Mm Thick After Priming Coat Complete All As Specified And Directed. 148 M&L For Preparation Of Complete Removal Of Existing Treatement Onoldplastered Surfaces Of Walls Applying Two Coats Of Distemper, Oil Emulsion, White Or Tinted Over Old Wall Surfaceon A Coat Of 1Mm Thick Wall Care Putty Over Primer Complete All As Specified And Directed. 149 Taking Down Carefully Copper / Aluminium Point Wiring ( Light, Socket Or Power ) Complete ( Fittings Such As Switches, Ceiling Roses, Pendants, Regulatos, Sockets Etc To Be Measured Separately ) , And Making Good Disturbed Surfaces Of Walls, Floors Etc To Match With Existing Surfaces. 150 M&L Point Wiring Complete With 1.5 Sqm Sincle Core Pvc Insulated Unsheathed Frls Cable 1100 Volts Grade ( Isi Marked ) With Multi Stranded Copper Conductor Drawn Through Conductor Drawn Through In Pvc Casing Caping ( Isi ) Marked, Wall / Ceiling Etc And Incl Provn Of 1.5 Sqmm Pvc Insulated Multistranded Unsheathed Copper Conductor Cable Frls ( Isi Marked ) As Earth Continuity Conductor, Fabricated Sunken Terminal Box Made Out Of 1.60 Mm Thick Sheet Steel Duly Painted Concealed In Walls, With 3Mm Thick Bakelite / Pvc Sheet Isi Marked Top Cover With Brass / Chromium Plated Screws And Cup Washers For Housing Switches, Socket Outlets, Fan Regulators Etc, All As Specified And As Directed.Note Quoted Rate Shall Include Chase Cutting Making Good To The Disturbed Surfaces Including Plastering And Painting To Match With Existing Colour. 151 A ) One Light Point Controlled By One, One Way Switch. 152 B ) One 3 Pin 5 Amps Switch Socket Outlet Pointon Independent Board. 153 C ) One 3 Pin Socket Outlet 5 Amps On The Same Board With Other Switches 154 D ) One Bell / Buzzer Point Controlled By One Push Button On The Same Board With Other Switches Or Independent 155 All As Per Item Sl. No. 150 Here In Before But Wiring With 2.5 Sq.Mm Multistranded Cable And Earth Wire With Copper Conductor Of Size 4 Sq.Mm. 156 All As Per Item Sl. No.150 Here In Before But Wiring With 4 Sq.Mm Multistranded Cable And Earth Wire With Copper Conductor Of Size 4 Sq.Mm. 157 Supply And Fix Switch Piano Flush Type Single Pole , One Way 6 Amp 230 Volts, 50Hz, Isi Marked All As Specified And As Directed. 158 Supply And Fix Socket Outlet 2 In 1, 3 Pin , 6A 230 Volts, 50Hz, Isi Marked All As Specified And As Directed. 159 Supply And Fix Socket, Outlet 2 In 1 , 3 Pin , 6 Amp And 16 Amp Flush Type 230 V 50Hz, Isi Marked All As Specified And As Directed. 160 Supply And Fix Switch Piano Flush Type Single Pole , One Way 16 Amp 230 Volts, 50Hz, Isi Marked All As Specified And As Directed. 161 S&F Ceiling Rose, 3 Phase , Pvc Polycarbonate , Insulated Body ( Isi Marked ) Complete All As Specified And Directed. 162 Supply & Fixing Led Lights Fitting Not Less Than 1X20 Watt 220 V, Ac Decorative Box Type With Driver , Holder Including Led Tube Light Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Complete All As Specified. 163 Supply & Fix Lamp Holder Angular / Straight Insulated Body, With Back Plate Suitable For Pendant Fittings, White / Ivory Finish With 15 Watt Led Bulb Complete All As Directed. 164 Supply & Fixing Buzzer Ding Dong Ac 230 Volts Single Pole With Suitable Fixing Arrangement Complete With All As Accessories All As Specified. 165 M&L Point Wiring Complete With 1.5 Sqm Sincle Core Pvc Insulated Unsheathed Frls Cable 1100 Volts Grade ( Isi Marked ) With Multi Stranded Copper Conductor Drawn Through And Including Non-Metallic Rigid Pvc Medium Grade Conduit And Conduit Accessories ( Isi ) Marked Concealed In Wall / Fixed To Roof, Ceiling Etc And Incl Provn Of 1.5 Sqmm Pvc Insulated Multistranded Unsheathed Copper Conductor Cable Frls ( Isi Marked ) As Earth Continuity Conductor, Fabricated Sunken Terminal Box Made Out Of 1.60 Mm Thick Sheet Steel Duly Painted Concealed In Walls, With 3Mm Thick Bakelite / Pvc Sheet Isi Marked Top Cover With Brass / Chromium Plated Screws And Cup Washers For Housing Switches, Socket Outlets, Fan Regulators Etc, All As Specified And As Directed. 166 A ) One Light Point Controlled By One, One Way Switch. 167 B ) One 3 Pin 5 Amps Switch Socket Outlet Pointon Independent Board. 168 Supply & Fixing Led Lights Fitting Not Less Than 1X18 Watt 220 V, Ac Decorative Box Type With Driver , Holder Including Led Tube Light Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Complete All As Specified. 169 Supply & Fix Lamp Holder Angular / Straight Insulated Body, With Back Plate Suitable For Batten Fittings, White / Ivory Finish Complete All As Directed. 170 Supply And Fix Exhaust Fan Made Of Sturdy Engineering Plastic Complete With Louvers Shutter , Voltage 230 V , 50 Hz Rpm 1200, Copper Winding Of Sweep 250 Mm Complete With All Accessories As Specified And As Directed. 171 Supply And Laying Dwc Pipe Sn-4 With Coupler 40Mm Od, Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Partii Complete With Fitting And Cutting , Jointing Etc. Laid In Trenches / Fixed To Pole / Laying Under Road Crossing / Fixed On Pavement Wall With Clamps Complete All As Specified And As Directed. 172 Supply , Laying , Jointing And Testing In Trenches Or Passing Through Pipe, 1100 Volts Grade Xlpe Insulated, Armoured Heavy Duty Electric Cable Withaluminium Conductor Of Cross Sectional Area 6 Sqmm 2 Core With Necessary Fixing Arrangements Such As Lugs, Glands And Terminal Etc Complete All As Specified And As Directed. 173 S&F For Mcb Db Spn 4 Ways Single Door With 200 Amp Rated Bus Bar , Ip-42, Ik-09, Metal Door, Earth Bar, Neutral Links Complete Incl Blanking Plates As Required & Fixed Flush To Wall / Other Surface Complete All As Specified And As Directed . 174 S&F Mcb Single Pole & Neutral Spn 32 Amps , 240 Volts , 10 Ka Rupturing Capacity , C Curve Complete All As Directed 175 S&F Mcb Single Pole 6 To32 Amps , 240 Volts , 10 Ka Rupturing Capacity , C Curve Complete All As Directed. 176 M&L For Earthing Complete With Galvanised Steel Earth Plate Electrode 600 X 600 X 6 Mm Thick Burrieddirectly In Ground ( Earth Pit Not Less Than 2.25 Meters Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5Mtrs Below Normal Ground Level Connected With Galvanised Iron / Steel Earth Wire Of 4 Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Made Out Of Galvanised Iron Or Steel All As Shown In Electrical Plateno 3 Of Ssr Part-I And Earth Wire Protected By Galvanized Pipe Light Grade 15Mm Bore Andconnectedto Dbs Including Necessary Earthwork And Excavation In Any Type Of Soil, Gi Light Grade 20Mm Bore Watering Pipe With Funnel And Wire Mesh, Pcc 1:2:4 Type B1 Chamber With 40Mm Thick Rcc 1:2:4 Type B1 Design Mix Cover Slab With 6Mm Dia Ms Bars At 100Mm C / C Both Ways With Ms Hook 6Mm Dia Ms Bars Etc Complete All As Specified And Directed By Engineer-In-Charge Includingtesting On Completion.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Dec-2023 Date amendment Date 18-01-2024
2 02-Jan-2024 Date Amendment Date 23-01-2024
3 15-Jan-2024 Amendment date Date 05-02-2024

Key Value

Document Fees
INR 1000 /-
EMD
INR 125000.0 /-
Tender Value
INR 64.80 Lakhs /-

BOQ Items

Name of Work: PROVN OF CERTAIN SANCTION WORKS UNDER GE GANGTOK
Sl. No. Item Description
1Dismantling of plain or corrugated steel sheeting , any gauge, thickness, including Nainital or similar pattern roof covering.
2Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
3Dismantling wrought iron or mild steel work of any description not otherwise provided for.
4Taking up or down 50mm bore steel water tubings and fittings etc complete and makinggood disturbed surfaces of walls/ceilings etc complete all as specified and as directed.
5Taking up or down 25mm bore steel water tubings and fittings etc complete and makinggood disturbed surfaces of walls/ceilings etc complete all as specified and as directed.
6Taking up or down 15mm bore steel water tubings and fittings etc complete and makinggood disturbed surfaces of walls/ceilings etc complete all as specified and as directed.
7Taking up or down 20mm bore steel water tubings and fittings etc complete and makinggood disturbed surfaces of walls/ceilings etc complete all as specified and as directed.
8Fixing only 50mm bore of tube, any grade, to walls and ceilings or laying in floors complete all as specified and directed.
9Fixing only 25mm bore of tube, any grade, to walls and ceilings or laying in floors complete all as specified and directed.
10Fixing only 15mm bore of tube, any grade, to walls and ceilings or laying in floors complete all as specified and directed.
11Fixing only 20mm bore of tube, any grade, to walls and ceilings or laying in floors complete all as specified and directed.
12M&L for 50mm bore steel tubing medium grade,galvanised fitting fixed complete to walls and ceiling or floor complete.
13M&L for 25mm bore steel tubing medium grade,galvanised fitting fixed complete to walls and ceiling or floor complete .
14M&L for 15mm bore steel tubing medium grade,galvanised fitting fixed complete to walls and ceiling or floor complete .
15M&L for 20mm bore steel tubing medium grade,galvanised fitting fixed complete to walls and ceiling or floor complete for this following.
16Taking down cement plaster of any description on brick or stone walls incl raking out joints hacking for key, scrubing down with water etc complete all as specified and directed.
17Demolition ofreinforcedconcrete of any description and in any position not otherwise specifically provided for .
18Demolition of precast concrete block walling/brick wall built in cement mortar
19M&L for pre cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setttingin cement mortar 1:6 type C1 1:3:6 (20 mm graded aggregate) complete.
20M&L for rendering 15mm thick in cement mortar 1:4 inusing WPC in finishing layer on brick or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed. (Note:-WPC for finishing layer will be paid seperately as supply only) .
21M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar (1:6) finished even & smooth without using extra cement complete all as specified and directed.
22M&L for rendering 5mm thick in cement mortar (1:3) on brick or concrete surfaces in ceilings, finished even and smooth without using extra cement complete all as specified and directed.
23Liquid waterproofing compound
24M &Lfor RCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in Slabs supported on wallsincluding necessary form work complete all as specified & as directed. NOTE:Re-inforcement shall be measured and paid separately.
25M&L for PCC(1:2:4),type B-1 (using 20mm graded stone aggregate) as in copingcomplete all as specified & as directed.
26Dismantling water tanks 5000 ltrs capacitycomplete all as specifiedand directed.
27Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. And hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. Measured separately) complete all as specified and directed
28S&F rotational moulded polythene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in postion (cylindrical vertical with closed top) hoisted and fixed in postion 5000 ltrs capacity complete all as specified and directed
29S&F in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for 25mm bore GI pipe all complete as specified and as directed
30S&F in repairs 25mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete as specified and as directed
31S&F rolled section as in main and cross beams hip, jack rafters,hollow section purlins, where connected to common rafters and running rails and guides for sliddinng doors fixed with angle cleats or other connecting plates of grade Fe-410, complete all as specifed & directed.
32M&L for two coats of synthetic enamel paint over a coat of red oxide primer to steel surfaces of any description over 10 cm in width or girth incl preparation of new steel surfaces complete all as specifed and directed.
33S&F as in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall, laid in trenches or in floor with all necessary clamps,bolts, bends, Tee etc complete all as specified and as directed.
34S&F as in repair 110 mm bore PVC (SWR) bends any radiuscomplete all as specified and directed.
35M&L for providing cement concrete 1:2:4 type B-1(using 20mm graded stone aggregate) as in roof padding/roof kerb to bring top surface of slab in slope complete all as specified and directed.
36M&L for 15 mm thick cement screed in cement mortar 1:3 admixed with approved integral water proofing compound as per manufacterer"s instructions.(Note:- FOSROC" complastx 412 IC @ 130 ml per bag cement incl a bonding coat of FOSROC"sNitco bond AR cement slurry or Shalimar Tar Product, Mumbai No 1 liquid@ 200 ml per bag or any equivalent approved make of products)
37M&L for applying one coat of industrial bitumen 85/25@1.2kg/Sqm over applying primer bitumen coat @ 0.30kg/Sqm including cleaning surfaces complete all as specified and directed.
38M&L APP based polymeric membrane minium weighing 3Kg/Sqm and minium 3 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/Sqm) laid on primed surface by forced application complete all as specified.
39M&L for plain cement concrete (1:2:4), type B2 (using 40 mm graded stone aggregates) in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases), complete all as specified and directed.
40Surface excavation n exc. (not exceeding) 30 cm deep and averaging 15cm deep and getting out soft/loose soil, all as specified and as directed.
41Rough excavation not exceeding 1.5 m deep and getting out in soft / loose soil, all as specified and directed.
42Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, laying of underground cables etc. or for shafts, wells, cesspits, manholes, pier holes, under groung cables etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil, complete all as specified and directed.
43Returning filling in soft / loose soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm, complete all as specified and directed.
44Removal of surplus excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point, complete all as specified and directed.
45M&L for plain cement concrete (1:4:8), type D2 (using 40 mm graded stone aggregates) as in foundation, filling and mass concrete, complete all as specified and directed.
46M&L for hardcore using broken stone or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
47M&L for stone walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar (1:6) including brought up to courses complete all as specified & as directed.
48M&Lfor 100 mm thickcement concrete 1:3:6type B-2 (using 40 mm graded stone aggregate) as inhardstanding/flooring/Path etc and finishing the surface even and fair etccomplete all as specified and directed.
49M&L for lacquer coated precast chequred cement concrete tiles made with grey cement and pigment of size 300 x 300 x 25 mm thick as in pavement / footpath, set and jointed in neat cement slurry and pointed with cement laid over laid over and including screed bed/bedding layer of 15mm thick in cemnt mortar (1:4) compelte all as directed.
50S&F for PVC(SWR)75mm pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor with necessary clamps, bolt, bends, Tee all as specified and directed.
51M&L for PCC(1:3:6),type C-1 (using 20mm graded stone aggregate) as in copingcomplete all as specified & as directed.
52M&L for rendering 15 mm thick in CM (1:4) on other than fair faces of stone masonry, finished even & fair with using extra cement complete all as specified and directed.
53M&L for Pre-cast cement concrete block masonry with Solid blocks, type C1 1:3:6 (20mm graded aggregate) exc 10cm in width and setting in mortar 1:6, complete all as specified and directed.
54S&F 5 to 6mm thick PVC wall/ceiling panels of interlocking types, width 250/255 mm with lamination design and exc 60% of PVC content including necessary H-joints, internal/external corner trim, coner cove,F/J edge trims where required fixed with hidden screws to steel/woodenframe work complete all as specified and as directed.
55M&L for applying two coats of white wash on old plastered wallsurfaceincluding preparation and previously untreatedsurfaces ofceiling allcomplete all as specified and directed .
56M&L for precast PCC 1:3:6 type C1 (by using 20mm graded stone aggregate)block masonry with solid blocks,exc 10 cm in width and setting in CM 1:6 complete all as specified and as directed.
57M&L for formwork to sides of concrete foundation, footings, bases of columns, raft and raft beams, sides & soffits (if any) foundation and plinth beam, retaining wall for rough finished surfaces of concrete complete all as specifed & directed.
58M&L RCC (Nominal mix) type B1, 1:2:4 using 20mm graded stone aggr as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed
59M&L forpre-cast RCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in manholes covers etc including necessary form work and set in CM 1:4 complete all as specified and directed. NOTE:Re-inforcement shall be measured and paid separately.
60M&L for formworks to sides and soffit of floor,roof beam, beam haunching, girders, bressummers, lintels, cantiliver shelves including support overhangs etc also splays between floor and beam etc complete all specifed and directed
61M&L for RCC 1:2:4 (nominal mix) 20mm graded aggregate as inbeams, cantilevers, bressumers, lintels over 1.5mspan complete all as specifed and directed.
62M&L for 75mm thick PCC type C-2 (1:3:6) using 40 mm graded agg in plinth protection path/hardstanding finished cement concrete surfaces fair and even including forming construction joint filled with CM (1:6) all as specified & directed.
63M&L rendering 15mm thick in CM 1:6 on other than fair faces of brick or concrete surfacescomplete all as specified and directed.
64M&L for rendering 15 mm thick in CM (1:4) in two layers of 10mm and 5mm (outer layer CM should be added with liquid WPC) on fair faces of brick or concrete surfaces, complete all as specified and directed.(Note:-WPC for finishing layer will be paid seperately as supply only) .
65Supply only liquid water proofing compound.
66M&L for non- skid Ceramic plain coloured tiles 7 to 8 mm thick (square / rectangular)conforming to IS 13712 grade B-II (a), approved make and colour shade, area of each tile exc 0.11 sqm but not exc 0.18 sqm , in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to matchover & including screed bed or bedding layer 15 mm thick in CM 1:4 complete all as specified & as dirceted.
67M&Lfor glazed ceramiccolouredtilesof size not less than 350x250x7mm/450x300x7mm mm thick fixed on vertical surfaces such as dado / skirting, raiser to steps etc conforming to IS - 13712 grade IB-III set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including screed bed / backing layer of 10 mm thick in cement mortar (1;3) complete all as specified & as dirceted.
68S&F rotational moulded polythene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in postion (cylindrical vertical with closed top) hoisted and fixed in postion 500 ltrs capacity complete all as specified and directed
69S&F for 15 mm bore angular stop cocks fancy type, chromium plated reduce body screwed down high pressure screwed both ends for iron pipe or for union etc as in repair.
70S&F bib taps 15mm bore fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
71S&F ball valve brass 20 mm dia high pressure with polythene float and fly nut complete secrewed for iron pipe or brass ferrule etc all as specified.
72S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for 20mm bore GI pipe all complete as specified and as directed
73S&F for 15 mm bore pillar taps of PTMTany colour high pressure screwed for iron pipe and fixed (Minimum weight 15mm- 110gms)all complete as specified and as directed
74M&L for plain cement concrete (1:3:6), type C2 (using 40 mm graded stone aggregates) in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases), complete all as specified and directed.
75Labour only for hand packing using broken stone or boulders (any thickness) at back of retaining walls over arches etc. and raising or lowering to the required level complete all as specified and directed.
76S&F Solid PVC door frame of size 50mm X 47mm made out of 5mm plain colourPVC sheet reinforced with MS square tubesupplying & fixing in opening as per specification and drawing complete all as specified and directed.
77S&F of 30mm thick (style thickness) factory made solid panel PVC door shutter consisting of frame made out of mild steel tubes for top and bottom rails, ild steel frame shall be covered with heat moulded single side prelam PVC "C" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and single side prelam PVC sheet for top rail, lock rail and bottom rail on either side & as gap insert for top rail and bottom rail on either side & as gap insert for toprail and bottom rail, panelling of both side prelam PVC sheet to be fitted in the mild steel frame welded /sealed to the stiles and rails with uitable PVC sheet beading and jointed together with solvent cement as per specification and drawing given on MES Schedule Part-II (2020) complete all as pecified and directed.
78S&F aluminum window and ventilator shutters, fixed type without sash bar, aluminum sectionweighing 0.55 Kg/m including necessary joining cleats, galzing clips, 4mm thick glass/AC board/particle board rubber neoprene packing incl aluminum grill and anodised aluminium snap beading screws etc.complete all as specified and directed.
79M&L for applyingtwo coat of white washing including preparation of new or previously untreated surface of ceiling complete all as specified and directed.
80M&L for applying two coats of exterior acrylic emulsion painting over a coat of alkali resistant primer including scaffolding upto 15m ht andpreperation of old/newsurfaces all as directed
81Excavation in post holes in soft/loose soil or similar holes each n exc 0.5 cum getting out returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm and remaning surplus soil removing to a distance n exc 50cm and making good surface, complete all as specified and directed.
82M&L for 150 mm size aluminium anodised cast type handles.
83S&F of 150mm long aluminium anodised,barrel tower bolt of extruded section.
84S&F of 75mm size mild steel butt hinges medium weight.
85S&F for 200 mm long aluminium anodised sliding door boltwith hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium complete all as specified and directed.
86S&F Vitreous China squatting pan of‘Orissa pattern’, size 580 mm x 440mm (white) with ‘P’ or ‘S’ trap, front or back inlet and foot rests, any pattern complete including provision of PCC bedding andconnection to trap, and to flushing pipe, antisyphonage pipe, etc. complete including making good to floorcomplete all as specified & as dirceted.
87S&FVitreous China, Wash Hand Basin, white, flat backof size 550 mm x 400 mm, including cutting for and pinning in ends of brackets or errecting stands and 15 mm bore PVC connector pipe, 32 mm dia chromium plated waste coupling, 32 mm dia PVC waste pipe complete all as specified & as dirceted.
88S&F PVC (SWR) floor trap 75mm, plain with grating including jointing with solvent cement complete all as specified & as dirceted.
89S&F 10 litre capacity low level PVC flushing cistern (any colour), syphonic action type, with inlet, ball valve, float, handle, fixed with cast iron bracket (of suitable size) and providing 32 mm dia PVC flush pipe and making all necessary connections complete (excluding PVC connection pipe) complete all as specified & as dirceted. Make : CERA, Cat No B1010107, Parry ware , Hindware orequivalent.
90S&F PVC connections 15 mm size with PTMT nuts of length 600mm complete all asspecified and directed. Make: Prayag Cat No 323 or equivalent.
91M&L for PCC 1:3:6 type C-2(by using 40 mm graded stone aggregate) as in bed to drain pipes 150 mm bore, including packing under and haunching against the sides of pipesafter they are laid and tested, complete all as specified and directed.
92S&F 150 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall, laid in trenches or in floor with necessary clamps, bolts, bends, Teeetc.complete all as specified and as directed.
93S&F fitting forPVC (SWR) pipes of75mm bore as PVC(SWR) junction double,(double T), equal or unequal provided with access door complete all as specified and as directed.
94S&F fitting forPVC (SWR) pipes of110mm bore as PVC(SWR) junction double,(double T), equal or unequal provided with access door complete all as specified and as directed.
95M&L for 100mm thick PCC 1:2:4 type B2 (using 40mm graded stone aggregate)as in sub-base of floor, path, hardstanding,floor etc. completeall as specified and as directed.
96S&F for 600 x 450mm looking mirror with aluminium channel frame, mounted on 6mm thick commercial plywood frame and fixed to wooden plug with chromium plated brass screws & cup washers incl glass self assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railling 60 cm long complete all as specified and directed.
97M&L Lacquer coated coloured chequered cement concrete tiles not less than 300 x 300mm x 25mm thick set, jointed and pointed in neat slurry in floors with grey cement and pigments over and incl 15mm thick screed bed or bedding layer of motar for laying floor finishes in cement plaster 1:4 all as specified and as directed.
98M&L for cutting into existing manholes for connecting new drains (internal dia pipe 150mm), making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-I smooth finished, and reforming benching all as specified and directed.
99S&F for0.50mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheets of any colour having tensile strength of 550 Mpa as in roof coveringfixed with self tapping screws as in roofcovering complete all as specified and directed.
100S&F for 0.50mm thick pre-painted galvalume aluminium zinc coating GI basedplain steel sheets of any colour having tensile strength of 550 Mpa as in roof coveringfixed with self tapping screws as in roofcomplete all as specified and directed.
101S&F for Harrison rail, mild steel,chromium plated , 25 mm dia with fixing brackets, stops, rollers, nob, holder etc in curtain rails complete all specified and directed.
102S&F powder coated grid frame work for false ceiling comprising of the following sections for making partitions of 600 x 600m size fixed to walls with rawl plugs & screws and hanged to roof with and including1mm dia GI wire suspender of suitable length and butterfly clips, size of main tee shall be 28mm x 23mm x 0.30mm thick, cross tee shall be 24mm x 23mmx0.30mm thick and wall angle shall be 20mm x 20mm x 0.30mm thick complete all as specified and as directed.
103S&F for4mm thick Non asbestos fibre cement building board (E-board) of approved texture for insulation and acoustic purpose of size 595x595 mm size fixed with staples on snap grid as in ceiling with and including dusting of surface and applying one coats of oil emulsion distemper over a coat of primer including preparation of surfaces complete all as specified and directed.
104M&L for Dark/Light shade non skid tiles 8-10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqmin floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colourincl 20mm thick screed bed in cement mortar (1:6) for laying floor/roof finishes complete all as specifiedand directed.
105All as per item No 104here-in-above but in skirting with 8-10 mm thick backing coat in CM ( 1:4) complete all as specified and directed.
106M&L for glazed colouredceramic tiles (350x250x7mm thick/450x300x7mm thick)on vertical surfaces such as skirting/dado set and jointed in neat cement slurry pointed in white or coloured cement to match the colour incl 10 mm thick screed bed/rendering of CM (1:4) as in wallall as specified and directed.
107M&L for 25 mm thick PCC (1:2:4) type B1 ( 20mm graded stone aggregate) , finished concrete surfaces even androughto receive floor finishes complete all as specifiedand directed.
108M&L for pre cast cement concrete block masonry with solid blocks with 10 cm in width and setttingin cement mortar 1:6 type C1 1:3:6 (20 mm graded aggregate) complete all as specified and directed.
109M&L forgranite (of any type) work 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in CM 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite granite stone including cutting and polishing etc including 20mm thick screed bed in CM 1:6 complete all as specified and directed
110M&Lfor rounding to edges of graniteslabs one edge such as in steps, cooking platforms and other similar situations complete all as specified and directed.
111S&F aluminum door shutters,aluminum section weighing 0.55 Kg/m including necessary joining cleats, galzing clips, rubber neoprene packing, 5mm thick glass/AC board/particle board, handles 02 Nos in each door hinges anodised aluminium snap beading screws etc xomplete all as specified and directed.
112S&F door closer of aluminium (extruded section) bodyhydraulically regulateduniversal type , suitable for door shutters of 701 to 850 mm in width and of weight between 36kgto60 kg and fixed.
113S&F aluminium anodised, aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
114Fabrication and fixing powder coated aluminium sliding (three tracks)/openable/fix type window/ventilator/partition wall with aluminium frame of section 62.30 x 44.50 x 1.5 mm with shutter stiles rail of aluminum section of size 47.62 x 44.45 x 1.5 mm thick includiing jointing cleat for fixing binder hardware glazing clips rubber packing for air lock purpose anodized aluminium strip bearing screw etc for fixing glass pans in frame shutter covered with fully selected quality tinted glass 4mm thick tinted/plain glass with rubber packing and locking arrangement complete all as spcified and as directed.
115M&L for use and waste of form work to soffits of suspended slab such as roof slabs, floor slabs, landing and similar works n. exceeding 200mm thick for flat fair finished surfaces of conceter complete all as specified and as directed.
116M&L for use and waste of form work to edges of concrete flats, treads, breaks in flooors, window cills, concrete railings, openings in concrete walls, floor and roofs exc 10 cm but n exc 20cm wide complete all as specified and as directed.
117M &Lfor RCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in Slabs supported on wallsincluding necessary form work complete all as specified & as directed. NOTE:Re-inforcement shall be measured and paid separately.
118M&L for TMT bars , 10 mm dia and over cut to length, bent to shape required including cranking ,bending spirally, hooping for columns,hookings/ends and binding with and including MS wire not less than 0.9 mm dia or securing with clips.
119M&L 15 mm thick rendering plaster on fair faces of conc faces in CM 1:6 complete all as specified and as directed.
120M&L for rendering 15mm thick in cement mortar 1:4 in two layers of 10mm and 5mm (outer layer CM should be added with WPC)in finishing layer on brick or concrete surfaces finished even & smooth without using extra cement complete all as specified and as directed. (Note:-WPC for finishing layer will be paid seperately as supply only).
121M&L for applying two coats of OBD over a coat of primer applied over providing and applying plaster of paris putty of minimum 1 mm thickness over plastered surface to prepare the surface even and smooth including complete removal of existing treatment andpreperation of old/new surfaces preparing the surfaces even and smooth.
122M&L for applying two coats of exterior acrylic emulsion painting over a coat of alkali resistant primer including complete removal of existing treatment andpreperation of old/newsurfaces complete all as specified and directed.
123S&F half round 150mm dia with rounded edges including all accessories/fittings like T , Y etc for eaves gutter complete all as specified and directed.
124S&F PVC (SWR) bends any radius 110 mm dia complete all as specified and directed.
125M&L for 75mm thick PCC type C2 1:3:6 (using 40mm graded stone agg) as inplinth protection/Path/hardstandingfinished the concrete surfaces even and smooth without using extra cement complete all as specified and directed.
126M&L for plain cement concrete(1:3:6), type C-2(40 mm graded stone aggregate) in surface channels and drains, complete all as specified and directed.
127M&L Lacquer coated coloured chequered cement concrete tiles not less than 300 x 300mm x 25mm thick set, jointed and pointed in neat slurry in floors and steps with grey cement and pigments over and incl 15mm thick screed bed or bedding layer of motar for laying floor finishes in cement plaster 1:6 all as specified and as directed.
128Demolition of Brickwork or stone/ boulder masonry, built in cement mortar complete all as dierceted.
129Taking down chowkats or frames with shutters (without taking off shutters from the frame) each area exc 1.5 sqm nut n.exc 4Sqm all as specified and as directed.
130Demolition to cement concrete in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
131M&L for pre cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setttingin cement mortar 1:4 type C1, (1:3:6) (using 20 mm graded stone aggregate) as per IS 383 complete all as specified and as directed.
132S&F2nd class Flush shutters 35mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as spd and direvcted .
133M&L for second class hard wood plain solid straight chowkats and frames wrought framed rebated on the solid rounded on chamfered put together with glue pinned and joints.
134Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and removal of dismantled materials/rubbish from site complete all as specified and directed.
135M&L for 25 mm thick PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in sub base of floorcomplete all as specified and as directed.
136S&FVirified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed or bedding layer in CM(1:6) all as spd and directed.
137Ditto all as item No. 136 above but on vertical surface of wall like skerting/dado etc on 15mm thick rendering complete.
138M&L for PCC 1:2:4type B1 (20 mm gradede aggregate ) as in coping, bed plates , parepet,plinth course including weathering, slightly rounded or chamfered angles and throating, all as specified and as directed.
139M&L for RCC Type B1 1:2:4 (using 20mm graded stone aggregate) as in foundations, including raft footings, foundation beams; plinth beams; bases for columns, Lintel beam,cover slabetc., basement slabs, under reamed piles and mass concrete incl necessary form workcomplete all as specified & as directed. NOTE:Re-inforcement shall be measured and paid separately.
140M&L for MS bars 5 mm dia and over upto and including 10 mm dia in stirrups cut to length, bent to shape required incl cranking bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire(annealed) not less than 0.9mm dia quality conforming to TMT bars complete all as specified and directed.
141S&F powder coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified
142S&F powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc, complete all as specified and directed.
143S&F5.5mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed.
144S&F5mm thick plain colour PVC sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent Cement and fixing at site complete all as specified and directed.
145S&F Aluminium body Door closer hydraulically regulated,designation No. 3,universal type, suitable for door shutters of 851to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
146S&F Safety lever locks mild steel with 4 levers for door shutters complete all as speciofied and directed.
147M&L for preparation of newplastered surfaces of walls applying two coats of distemper, oil emulsion, white or tinted over newwall suface on a coat wall care putty 1mm thick after priming coat complete all as specified and directed.
148M&L for preparation of complete removal of existing treatement onoldplastered surfaces of walls applying two coats of distemper, oil emulsion, white or tinted over old wall surfaceon a coat of 1mm thick wall care putty over primer complete all as specified and directed.
149Taking down carefully copper/aluminium point wiring (light, socket or power) complete (fittings such as switches, ceiling roses, pendants, regulatos, sockets etc to be measured separately),and making good disturbed surfaces of walls, floors etc to match with existing surfaces.
150M&L point wiring complete with 1.5 Sqm sincle core PVC insulated unsheathed FRLS cable 1100 volts grade (ISI marked) with multi stranded copper conductor drawn through conductor drawn through in PVC casing caping (ISI) marked, wall/ ceiling etc and incl provn of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS (ISI marked) as earth continuity conductor, fabricated sunken terminal box made out of 1.60 mm thick sheet steel duly painted concealed in walls, with 3mm thick bakelite/PVC sheet ISI marked top cover with brass/chromium plated screws and cup washers for housing switches, socket outlets, fan regulators etc, all as specified and as directed.Note quoted rate shall include chase cutting making good to the disturbed surfaces including plastering and painting to match with existing colour.
151a) One Light point controlled by one, one way switch.
152b) One 3 pin 5 amps switch socket outlet pointon independent board.
153c) One 3 pin socket outlet 5 amps on the same board with other switches
154d) One bell/buzzer point controlled by one push button on the same board with other switches or independent
155All as per item Sl. No. 150 here in before but wiring with 2.5 sq.mm multistranded cable and earth wire with copper conductor of size 4 sq.mm.
156All as per item Sl. No.150 here in before but wiring with 4 sq.mm multistranded cable and earth wire with copper conductor of size 4 sq.mm.
157Supply and fix switch piano flush type single pole , one way 6 Amp 230 Volts,50Hz, ISI marked all as specified and as directed.
158Supply and fix Socket outlet 2 in 1, 3 pin ,6A 230 Volts,50Hz, ISI marked all as specified and as directed.
159Supply and fix Socket, outlet 2 in 1 , 3 pin , 6 Amp and 16 amp flush type 230 V 50Hz,ISI marked all as specified and as directed.
160Supply and fix switch piano flush type single pole , one way 16 Amp 230 Volts,50Hz, ISI marked all as specified and as directed.
161S&F ceiling rose, 3 phase ,PVC polycarbonate ,insulated body (ISI Marked) complete all as specified and directed.
162Supply & fixing LED lights fitting not less than 1x20 watt 220 V, AC decorative box type with driver , holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified.
163Supply & fix lamp holder angular/straight insulated body, with back plate suitable for pendant fittings, white/ivory finish with 15 watt LED bulb complete all as directed.
164Supply & fixing Buzzer Ding Dong AC 230 volts single pole with suitable fixing arrangement complete with all as accessories all as specified.
165M&L point wiring complete with 1.5 Sqm sincle core PVC insulated unsheathed FRLS cable 1100 volts grade (ISI marked) with multi stranded copper conductor drawn through and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI) marked concealed in wall/fixed to roof, ceiling etc and incl provn of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS (ISI marked) as earth continuity conductor, fabricated sunken terminal box made out of 1.60 mm thick sheet steel duly painted concealed in walls, with 3mm thick bakelite/PVC sheet ISI marked top cover with brass/chromium plated screws and cup washers for housing switches, socket outlets, fan regulators etc, all as specified and as directed.
166a) One Light point controlled by one, one way switch.
167b) One 3 pin 5 amps switch socket outlet pointon independent board.
168Supply & fixing LED lights fitting not less than 1x18 watt 220 V, AC decorative box type with driver , holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified.
169Supply & fix lamp holder angular/straight insulated body, with back plate suitable for batten fittings, white/ivory finish complete all as directed.
170Supply and fix exhaust fan made of sturdy engineering plastic complete with louvers shutter , voltage 230 v ,50 hz RPM 1200, copper winding of sweep 250 mm complete with all accessories as specified and as directed.
171Supply and laying DWC pipe SN-4 with coupler 40mm OD, ISI marked along with all accessories like socket, bend, couplers etc. Conforming to IS 14930, PartII complete with fitting and cutting , jointing etc. Laid in trenches/fixed to pole /laying under road crossing /fixed on pavement wall with clamps complete all as specified and as directed.
172Supply ,laying ,jointing and testing in trenches or passing through pipe, 1100 Volts grade XLPE insulated, armoured heavy duty electric cable withaluminium conductor of cross sectional area 6 Sqmm 2 core with necessary fixing arrangements such as lugs, glands and terminal etc complete all as specified and as directed.
173S&F for MCB DB SPN 4 ways Single Door with 200 Amp rated bus bar ,IP-42,IK-09, metal door, earth bar, neutral links complete incl blanking plates as required & fixed flush to wall / other surface complete all as specified and as directed .
174S&F MCB single pole & neutral SPN 32 Amps , 240 Volts , 10 KA rupturing capacity , C curve complete all as directed
175S&F MCB single pole 6 to32 Amps , 240 Volts , 10 KA rupturing capacity , C curve complete all as directed.
176M&L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burrieddirectly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5mtrs below normal ground level connected with galvanised iron/steel earth wire of 4 mm dia by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel all as shown in electrical plateNo 3 of SSR Part-I and earth wire protected by galvanized pipe light grade 15mm bore andconnectedto DBs including necessary earthwork and excavation in any type of soil, GI light grade 20mm bore watering pipe with funnel and wire mesh, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type B1 design mix cover slab with 6mm dia MS bars at 100mm c/c both ways with MS Hook 6mm dia MS bars etc complete all as specified and directed by Engineer-in-Charge includingtesting on completion.