}

Tender For Smps Based Ips System Etc., Asansol-Uttar Pradesh

North Eastern Railways has published Tender For Smps Based Ips System Etc.. Submission Date for this Tender is 29-12-2023. Railway Ancillaries Tenders in Asansol Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

40850017
Tender For Smps Based Ips System Etc.
Tender
Indian
Uttar Pradesh
Asansol
29-12-2023

Tender Details

Supply Of Smps Based Ips System Etc., Integrated Power Supply ( Ips ) Supply, Installation, Testing And Commissioning Of Smps Based Integrated Power Supply ( Ips ) Confirming To Rdso Specification No. Rdso / Spn / 165 / 2012 Rev. 3.0 Or Latest Amendment And Sketch No. Ner Rly. Drg No. Typ / 0023 / Ips / 1 For Ips Up To 6 Lines Without Aftc Re Area Along With 300 Ah Lmla Battery. Technical Specification:- A. Specification No. Rdso / Spn / 165 / 2012 Rev. 3.0 Or Latest Amendment. B. Applicable Sketch No. Ner Rly. Drg No. Typ / 0023 / Ips / 1 ( Attached As Ips Approved Diagram ) C. Type Of Battery: 300 Ah Lmla. D. Dc-Dc Converter For Ssi / Data Logger: Yes, All Optional Items Are Required . E. Dc-Dc Converter For Axle Counter: Yes, Required. F. Dc-Dc Converter For Block Working : [ 40-100 V, 5A ] . G. Spare As Per Annexure- Iv Of Spec.- Yes, Required. H. Type Of External & Internal Relays: 24 V, Q Type Relays. I. Dc-Dc Converter ( 24-32V / 5A ) - 04 Nos. [ For Block Telephone / Mt ] . J. Distance Between Ips Room To Asm Panel ( In Meter ) :50-100 Meters. K. Distance Between Ips Rack Battery ( In Meter ) : 20-30 Meters. L. Whether Installation Is To Be Done By Oem-Yes. [ Warranty Period: 30 Months After The Date Of Delivery ] , Supply, Installation, Testing And Commissioning Of Smps Based Integrated Power Supply ( Ips ) Confirming To Rdso Specification No. Rdso / Spn / 165 / 2012 Rev. 3.0 Or Latest Amendment And Sketch No. Sdo / Ips / Pi-6L / Re / 004 For Ips Up To 6 Lines Without Aftc Re Area Along With 300 Ah Lmla Battery. Technical Specification:-:- A. Specification No. Rdso / Spn / 165 / 2012 Rev. 3.0 Or Latest Amendment. B. Applicable Sketch No. Sdo / Ips / Pi-6L / Re / 004. C. Type Of Battery: 300 Ah Lmla. D. Dc-Dc Converter For Ssi / Data Logger: Yes, All Optional Items Are Required . E. Dc-Dc Converter For Axle Counter: Yes, Required. F. Dc-Dc Converter For Block Working : [ 12-40V, 1 Amp. ] G. Spare As Per Anexure- Iv Of Spec.- Yes, Required. H. Type Of External & Internal Relays: 24 V, Q Type Relays. I. Dc-Dc Converter ( 3-6V / 0.1A ) - 04 Nos. [ For Block Telephone / Mt ] . J. Distance Between Ips Room To Asm Panel ( In Meter ) :50-100 Meters. K. Distance Between Ips Rack Battery ( In Meter ) : 20-30 Meters. L. Whether Installation Is To Be Done By Oem-Yes. [ Warranty Period: 30 Months After The Date Of Delivery ] , Smps Based Ips System 110V / 200Ah / 500Va As Per Rdso / Spn / 165 / 2012 Including Amendment With Low Maintenance Secondry Cell 200Ah As Per Specification No. 88 / 2004 [ Warranty Period: 30 Months After The Date Of Delivery ] , Supply, Installation, Testing & Commissioning Of Ips System As Per Rdso Spec No. Rdso / Spn / 165 / 2012 Ver 3.0 With Latest Amendment And Attached Drawing. [ Warranty Period: 30 Months After The Date Of Delivery ] , Supply, Installation And Commissioning Of Smps Based Integrated Power Supply ( Ips ) For Interlocked Lc Gate In Re / Non-Re Area Confirming To Rdso Specification No. Rdso / Spn / 165 / 2012 Rev. 3.0 Or Latest Amendment And Sketch No. Sdo / Ips / Lc / 007 Along With 200 Ah Lmla Battery. Technical Specification :- A. Specification No. Rdso / Spn / 165 / 2012 Rev. 3.0. B. Applicable Sketch No. Sdo / Ips / Lc / 007. C. Type Of Battery: 200Ah Lmla. D. Dc-Dc Converter For Ssi / Data Logger: Not Required. E. Dc-Dc Converter For Axle Counter : Not Required. F. Dc-Dc Converter For Block Working : Not Required. G. Spares As Per Annexue-Iv Of Spec. - Yes, Required. H. Types Of External And Internal Relays : 24V, Q Series Relays. I. Dc-Dc Converter ( 3- 6V / 0.1A ) - 04 Nos. [ For Block Telephone / Mt ] . J. Distance Between Ips Room To Asm Panel ( In Meter ) : 50-100 Meters. K. Distance Between Ips Rack Battery ( In Meter ) : 20-30 Meters. L. Transformer 230 / 110V, 500 Va - 01 No.- Required For Elb 110V Ac. M. Whether Installation Is To Be Done By Oem- Yes. [ Warranty Period: 30 Months After The Date Of Delivery ] , Supply Installation Testing Commissioning Of Smps Based Ips As Per Rdso Specification No. Rdso / Spn / 165 / 2012 Version 3 Or Latest For Mid Section Interlocked Lc Gate In Re Area. [ Warranty Period: 30 Months After The Date Of Delivery ] , Supply, Installation, Testing & Commissioning Of Ips System As Per Rdso Spec No. Rdso / Spn / 165 / 2012 Ver 3.0 With Latest Amendment And Attached Drawing. [ Warranty Period: 30 Months After The Date Of Delivery ] Page 2 Of 7 Run Date / Time: 29 / 11 / 2023 13:12:51Stores / North Eastern Rly Tender Document

Key Value

Document Fees
Refer document
EMD
INR 908020.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail