Bharat Sanchar Nigam Limited-BSNL has published Tender For Rate Contract For Repairing Of Air Conditioners And Electrical Installations At Various T.E. Bldgs And Bts Sites In Jammu Ba ( 2023-24 ).. Submission Date for this Tender is 13-11-2023. Dismantling Work Tenders in Kathua Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

40449832
Tender For Rate Contract For Repairing Of Air Conditioners And Electrical Installations At Various T.E. Bldgs And Bts Sites In Jammu Ba ( 2023-24 ).
Open Tender
Indian
Jammu And Kashmir
Kathua
13-11-2023

Tender Details

Rate Contract For Repairing Of Air Conditioners And Electrical Installations At Various T.E. Bldgs And Bts Sites In Jammu Ba ( 2023-24 ) ; 1 Replacement / Supplying & Laying Of 2 X 1.5 Sq Mm Pvc Insulated, Pvc Sheathed Flexible Copper Conductor Unarmoured Cable Of 1.1Kv Grade On Surface / Wall I / C Making Connections, Testing Etc Complete As Reqd. ( Isi Make ) 2 Replacement / Supplying & Laying Of 3 X 1.5 Sq Mm Pvc Insulated, Pvc Sheathed Flexible Copper Conductor Unarmoured Cable Of 1.1Kv Grade On Surface / Wall I / C Making Connections, Testing Etc Complete As Reqd. ( Isi Make ) 3 Replacement / Supplying & Laying Of 3 X 2.5 Sqmm Pvc Insulated, Pvc Sheathed Flexible Copper Conductor Unarmoured Cable Of 1.1Kv Grade On Surface / Wall I / C Making Connections, Testing Etc Complete As Reqd. ( Isi Make ) 4 Replacement / Supplying & Laying Of 3 X 4 Sq Mm Pvc Insulated, Pvc Sheathed Flexible Copper Conductor Unarmoured Cable Of 1.1Kv Grade On Surface / Wall I / C Making Connections, Testing Etc Complete As Reqd. ( Isi Make ) 5 Replacement Of Faulty2x 40 W / 1 X 40 W / Box Type Flourescent Fitting / Supplying & Fixing Of 4 Long 18 / 20 Watt Led Fittingas Light Source, Suitable For Operation On 220 Volt Single Phase Ac Supply Complete Connections Etc. Complete As Reqd. ( M / S Crompton / Havells Of Similar Superior Make ) 6 Replacement Of Faulty Lamp / Supplying & Fixing New 9 / 10 Watt Led Lampin The Existing Fitting Etccomplete T &C As Required 7 Replacement Of Faulty Lamp I / Supplying & Fixing New 20 Watt Led Lamp In The Existing Fitting Etccomplete T &C As Required 8 Rewinding Of Wall Fans / Ceiling Fans Of All Size Complete Withremoving From Site, Shifting To Workshop For Repairs, Strip Opening / Dismantling For Repairs, Winding With Suitable Size Good Quality Copper Wire, Replacement Of Faulty Bearing / Bushes Etc. As Required, Varnishing, Drying, Refixing Of Repaired Fan At Site Etc. Complete As Reqd. 9 Replacement / Supplying And Fixing 25 Watt Ledstreet Lightenergy Saving Dust And Water Proof Led Fitting With Inbuilt Controller Suitable For Operation On 220 V To 240 Volt Etc. On Existing Duly Fixed On The Existing Gi Bracket With Nuts & Bolts Etc Reqd. ( M / S Havells, Philips, Cg, Bajaj, Wipro Or Ss Make ) 10 Carrying Out Wet Servicingof 1.5Tr / 2Tr Window / Split Ac Unit I / C Removing, Cleaning All Components And Filters, De-Dusting By High Pressure Air Blower, Washing Condenser, Evaporator I / C Chemical Cleaning ( If Required ) , Refixing, Tightening Electrical Connections, Minor Repairs, If Required, Testing Of Ac Unit, Recording All Parameters In Service Reportetc As Reqd. 11 Charging Of Refrigerant Gas In Split Air Conditioner Complete With Carrying Out Leak Testing Of 1.5Tr / 2 Tr Split Ac Units With Nitrogen Gas Including Flushing The System, Brazing / Flaring The Leak Points, Vacumising, Purging And Making The System Leak Proof I / C Transportation Of Nitrogen Cylinder, Brazing Kit & Vacuum Pump, Supplying & Charging Of Refrigerant Gas At Site, Testing & Commissioning Etc As Required. 12 Replacement Of Faulty / Defective1.5 Tr Capacitycompressor With Newsealed Compressor I / C Dismantling Of Faulty Compressor, Cutting Refrigerant Piping, Brazing & Making Necessary Addition / Alteration I / C Proper Mounting On Base Plate, Connection Of Suction And Discharge Lines, Leak Test , Supplying & Charging Required Qty. Refrigerant Gas I / C Testing Commissioning Etc As Reqd. ( M / S Emerson / Tecumseh / Ss Make ) ( Note - The Firm Shall Submit Test Certificate Or Documentary Proof Towards Purchase Of New / Oem Factory Repaired Compressor. ) The Defective Compressor Shall Be The Property Of Agency & Firm Should Consider Suitable Price Rebate For The Same While Quoting. The Material Under Replacement Shall Be Similar To Existing Defective Material Or As Per Product Directory ) 13 Replacement Of Faulty / Defective2.0 Tr Capacitycompressor With Newsealed Compressor I / C Dismantling Of Faulty Compressor, Cutting Refrigerant Piping, Brazing & Making Necessary Addition / Alteration I / C Proper Mounting On Base Plate, Connection Of Suction And Discharge Lines, Leak Test , Supplying & Charging Required Qty. Refrigerant Gas I / C Testing Commissioning Etc As Reqd. ( M / S Emerson / Tecumseh / Ss Make ) ( Note - The Firm Shall Submit Test Certificate Or Documentary Proof Towards Purchase Of New / Oem Factory Repaired Compressor. ) The Defective Compressor Shall Be The Property Of Agency & Firm Should Consider Suitable Price Rebate For The Same While Quoting. The Material Under Replacement Shall Be Similar To Existing Defective Material Or As Per Product Directory ) 14 Replacement Of Faulty Damaged Condenser Fan Motor For Split Ac Unit In Existing Window / Split Ac Units Including Removal Of Faulty Spares, Supplying And Fixing New One Testing, Commissioning Etc., Complete As Required. ( Note- The Defective Material Shall Be The Property Of Agency & Firm Should Consider Suitable Price Rebate For The Same While Quoting. The Material Under Replacement Shall Be Similar To Existing Defective Material Or As Per Product Directory ) . 15 Replacement Of Faulty Damaged Indoor Fan Motor For Split Ac Unit In Existing Window / Split Ac Units Including Removal Of Faulty Spares, Supplying And Fixing New One Testing, Commissioning Etc., Complete As Required. ( Note- The Defective Material Shall Be The Property Of Agency & Firm Should Consider Suitable Price Rebate For The Same While Quoting. The Material Under Replacement Shall Be Similar To Existing Defective Material Or As Per Product Directory ) . 16 Replacement Of Faulty Damaged Blower In Existing Window / Split Ac Units Including Removal Of Faulty Spares, Supplying And Fixing New One Testing, Commissioning Etc., Complete As Required. ( Note- The Defective Material Shall Be The Property Of Agency & Firm Should Consider Suitable Price Rebate For The Same While Quoting. The Material Under Replacement Shall Be Similar To Existing Defective Material Or As Per Product Directory ) . 17 Replacement Of Faulty Damaged Pcb Assembly Main In Existing Window / Split Ac Units Including Removal Of Faulty Spares, Supplying And Fixing New One Testing, Commissioning Etc., Complete As Required. ( Note- The Defective Material Shall Be The Property Of Agency & Firm Should Consider Suitable Price Rebate For The Same While Quoting. The Material Under Replacement Shall Be Similar To Existing Defective Material Or As Per Product Directory ) . 18 Replacement Of Faulty Damaged 5-32 A Dp Mcb C-Series In Existing Window / Split Ac Units Including Removal Of Faulty Spares, Supplying And Fixing New One Testing, Commissioning Etc., Complete As Required. ( Note- The Defective Material Shall Be The Property Of Agency & Firm Should Consider Suitable Price Rebate For The Same While Quoting. The Material Under Replacement Shall Be Similar To Existing Defective Material Or As Per Product Directory ) . 19 Replacement Of Faulty Damaged Fan Blade In Existing Window / Split Ac Units Including Removal Of Faulty Spares, Supplying And Fixing New One Testing, Commissioning Etc., Complete As Required. ( Note- The Defective Material Shall Be The Property Of Agency & Firm Should Consider Suitable Price Rebate For The Same While Quoting. The Material Under Replacement Shall Be Similar To Existing Defective Material Or As Per Product Directory ) . 20 Replacement Of Faulty Damaged Pcb Control Card Of 1.5 Tr Inverter Type Ac Unit For I / D Unit In Existing Window / Split Ac Units Including Removal Of Faulty Spares, Supplying And Fixing New One Testing, Commissioning Etc., Complete As Required. ( Note- The Defective Material Shall Be The Property Of Agency & Firm Should Consider Suitable Price Rebate For The Same While Quoting. The Material Under Replacement Shall Be Similar To Existing Defective Material Or As Per Product Directory ) . 21 Replacement Of Faulty Damaged Pcb Control Card Of 1.5 Tr Inverter Type Ac Unit For O / D Unit In Existing Window / Split Ac Units Including Removal Of Faulty Spares, Supplying And Fixing New One Testing, Commissioning Etc., Complete As Required. ( Note- The Defective Material Shall Be The Property Of Agency & Firm Should Consider Suitable Price Rebate For The Same While Quoting. The Material Under Replacement Shall Be Similar To Existing Defective Material Or As Per Product Directory ) . 22 Replacement Of Faulty Damaged Copper Piping For Hot & Cold Lines In Existing Window / Split Ac Units Including Removal Of Faulty Spares , Supplying And Fixing New Onetesting , Commissioningetc., Complete As Required. ( Note- The Defective Material Shall Be The Property Of Agency & Firm Should Consider Suitable Price Rebate For The Same While Quoting. The Material Under Replacement Shall Be Similar To Existing Defective Material Or As Per Product Directory ) . 23 Replacement Of Choked / Faulty 20 Mm Dia Pvc Drain Pipe In Recess Or On Surface For Drainage Of Split Ac Units I / C Connections Etc Complete As Reqd. 24 Replacement / Supplying & Laying Of Faulty / Burnt Lt Cable Of 1.1 Kv Grade With 4 X 16 Sq Mm Xple Insulated Aluminum Conductor Steel Armored Cable Of 1.1 Kv Grade Including Laying On Surface / Wall Etc. Complete As Required. ( Note-Unserviceable / Damaged Cable Shall Be Property Of The Agency, Rates Shall Be Quoted Accordingly ) 25 Replacement Of Faulty / Supplying And Fixing Of125 A, 415 V, Four Pole, On Load, Front Operated Open Execution Type Changeover Switchsuitable For Operation On3-Phase, 50 Hz Supplyincluding Interconnections , Complete As Required ( Bsnl Appd. Makes ) . ( Note-Unserviceable / Damaged Components Shall Be Property Of The Agency, Rates Shall Be Quoted Accordingly ) 26 Replacement Of Faulty Fan Condenser With New Onecomplete As Required 27 Replacement Of Faulty Step Type Fan Regulator With New Onecomplete As Required 28 Replacement Of Faulty Starting Capacitor Along With Relay With New Onefor Split / Window Type Ac Unit Complete As Required 29 Replacement Of Faulty Running Capacitor With New Onefor Split / Window Type Ac Unit Complete As Required 30 Replacement / Supplying And Fixing Offire Extinguishers Of 4.5 Kg Co2 Type Complete With Delivery Hose Horn, Squeeze Grip / Wheel Type Release Valve, Locking Arrangement, Operating Manual And Hanging Arrangement Complete With Installation At Site Complete As Required ( Isi ) 31 Refilling Of Fire Extinguishers Of Co2 Type 4.5 Kg Type With Co2 Gas Complete Shifting From Site To Workshop, Refilling And Reinstallation At Site Alongwith Providing Minor Repairs / Replacement Of Hose Pipe, Painting With Fire Red Colour Paint Etc. Complete As Required. 32 Rewinding Of 0.5 Hpmotor Complete Using Suitable Gauge Copper Wire As Required 33 Rewinding Of 1 Hpmotor Complete Using Suitable Gauge Copper Wire As Required 34 Replacement Of Faulty Heating Element Of Geyser Complete As Required 35 Replacement Of Faulty Thermostat Of Geyser Complete As Required

Key Value

Document Fees
INR 590 /-
EMD
INR 59039.0 /-
Tender Value
INR 29.51 Lakhs /-

BOQ Items

Name of Work: RATE CONTRACT FOR REPAIRING OF AIR CONDITIONERS AND ELECTRICAL INSTALLATIONS AT VARIOUS T.E. BLDGS AND BTS SITES IN JAMMU BA (2023-24)
Sl. No. Item Description
1Replacement / supplying & laying of 2 x 1.5 Sq mm PVC insulated, PVC sheathed flexible copper conductor unarmoured cable of 1.1KV Grade on surface/wall i/c making connections, testing etc complete as reqd. (ISI Make)
2Replacement / supplying & laying of 3 x 1.5 Sq mm PVC insulated, PVC sheathed flexible copper conductor unarmoured cable of 1.1KV Grade on surface/wall i/c making connections, testing etc complete as reqd. (ISI Make)
3Replacement / supplying & laying of 3 x 2.5 Sqmm PVC insulated, PVC sheathed flexible copper conductor unarmoured cable of 1.1KV Grade on surface/wall i/c making connections, testing etc complete as reqd. (ISI Make)
4Replacement / supplying & laying of 3 x 4 Sq mm PVC insulated, PVC sheathed flexible copper conductor unarmoured cable of 1.1KV Grade on surface/wall i/c making connections, testing etc complete as reqd. (ISI Make)
5Replacement of faulty2X 40 W / 1 x 40 W / box type flourescent fitting / supplying & fixing of 4" long 18/20 Watt LED fittingas light source, suitable for operation on 220 volt single phase ac supply complete connections etc. complete as reqd.( M/s Crompton / Havells of similar superior make )
6Replacement of faulty lamp / supplying & fixing new 9/10 Watt LED lampin the existing fitting etccomplete T &C as required
7Replacement of faulty lamp i/ supplying & fixing new 20 Watt LED lamp in the existing fitting etccomplete T &C as required
8Rewinding of Wall Fans / Ceiling Fans of all size complete withremoving from site, shifting to workshop for repairs, strip opening /dismantling for repairs,winding with suitable size good quality copper wire, replacement of faulty bearing/ bushes etc. as required, varnishing, drying,refixing of repaired fan at site etc. complete as reqd.
9Replacement / Supplying and fixing 25 Watt LEDStreet LightEnergy saving dust and water proof LED fitting with inbuilt controller suitable for operation on 220 V to 240 Volt etc. on existing duly fixed on the existing GI bracket with nuts & bolts etc reqd.( M/s Havells, Philips, CG, Bajaj, Wipro or SS make)
10Carrying out Wet Servicingof 1.5TR / 2TR Window / Split AC unit i/c removing, cleaning all components and filters, de-dusting by high pressure air blower, washing condenser, evaporator i/c chemical cleaning (if required), refixing, tightening electrical connections, minor repairs, if required, testing of AC unit, recording all parameters in service reportetc as reqd.
11Charging of refrigerant gas in split air conditioner complete with carrying out leak testing of 1.5TR/ 2 TR Split AC units with nitrogen gas including flushing the system, brazing/flaring the leak points, vacumising, purging and making the system leak proof i/c transportation of nitrogen cylinder, brazing kit & vacuum pump, supplying & charging of refrigerant gas at site, testing & commissioning etc as required.
12Replacement of faulty /defective1.5 TR capacitycompressor with newSealed compressor i/c dismantling of faulty compressor, cutting refrigerant piping, brazing & making necessary addition/alteration i/c proper mounting on base plate, connection of suction and discharge lines, Leak test , supplying & charging required qty. refrigerant gas i/c testing commissioning etc as reqd.(M/s Emerson/Tecumseh/SS make) (Note - The firm shall submit test certificate or documentary proof towards purchase of New/OEM factory repaired compressor.) The defective compressor shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory)
13Replacement of faulty /defective2.0 TR capacitycompressor with newSealed compressor i/c dismantling of faulty compressor, cutting refrigerant piping, brazing & making necessary addition/alteration i/c proper mounting on base plate, connection of suction and discharge lines, Leak test , supplying & charging required qty. refrigerant gas i/c testing commissioning etc as reqd.(M/s Emerson/Tecumseh/SS make) (Note - The firm shall submit test certificate or documentary proof towards purchase of New/OEM factory repaired compressor.) The defective compressor shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory)
14Replacement of faulty damaged Condenser Fan Motor for Split AC unit in existing window / split AC units including removal of faulty spares, supplying and fixing new one testing, commissioning etc., complete as required. (NOTE- The defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory).
15Replacement of faulty damaged Indoor Fan Motor for Split AC unit in existing window / split AC units including removal of faulty spares, supplying and fixing new one testing, commissioning etc., complete as required. (NOTE- The defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory).
16Replacement of faulty damaged Blower in existing window / split AC units including removal of faulty spares, supplying and fixing new one testing, commissioning etc., complete as required. (NOTE- The defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory).
17Replacement of faulty damaged PCB assembly main in existing window / split AC units including removal of faulty spares, supplying and fixing new one testing, commissioning etc., complete as required. (NOTE- The defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory).
18Replacement of faulty damaged 5-32 A DP MCB C-series in existing window / split AC units including removal of faulty spares, supplying and fixing new one testing, commissioning etc., complete as required. (NOTE- The defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory).
19Replacement of faulty damaged Fan blade in existing window / split AC units including removal of faulty spares, supplying and fixing new one testing, commissioning etc., complete as required.(NOTE- The defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory).
20Replacement of faulty damaged PCB Control card of 1.5 TR inverter type AC unit for I/D unit in existing window / split AC units including removal of faulty spares, supplying and fixing new one testing, commissioning etc., complete as required. (NOTE- The defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory).
21Replacement of faulty damaged PCB Control card of 1.5 TR inverter type AC unit for O/D unit in existing window / split AC units including removal of faulty spares, supplying and fixing new one testing, commissioning etc., complete as required.(NOTE- The defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory).
22Replacement of faulty damaged Copper piping for Hot & cold lines in existing window / split AC units including removal of faulty spares , supplying and fixing new onetesting , commissioningetc., complete as required.(NOTE- The defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory).
23Replacement of choked / faulty 20 mm dia PVC drain pipe in recess or on surface for drainage of split AC units i/c connections etc complete as reqd.
24Replacement / supplying & laying of faulty / burnt LT cable of 1.1 KV grade with 4 x 16 sq mm XPLE insulated aluminum conductor steel armored cable of 1.1 KV grade including laying on surface/ wall etc. complete as required. (Note-Unserviceable / damaged cable shall be property of the agency, Rates shall be quoted accordingly)
25Replacement of faulty /Supplying and fixing of125 A, 415 V, Four Pole, On load, front operated open execution type Changeover switchsuitable for operation on3-Phase, 50 Hz supplyincluding interconnections , complete as required (BSNL Appd. Makes). (Note-Unserviceable / damaged components shall be property of the agency, Rates shall be quoted accordingly)
26Replacement of faulty fan condenser with new onecomplete as required
27Replacement of faulty step type fan regulator with new onecomplete as required
28Replacement of faulty starting capacitor along with relay with new onefor split/ window type AC unit complete as required
29Replacement of faulty running capacitor with new onefor split / window type AC unit complete as required
30Replacement /supplying and fixing offire extinguishers of 4.5 Kg CO2 type complete with delivery hose horn, squeeze grip/ wheel type release valve, locking arrangement, operating manual and hanging arrangement complete with installation at site complete as required (ISI)
31Refilling of fire extinguishers of CO2 type 4.5 Kg type with CO2 Gas complete shifting from site to workshop, refilling and reinstallation at site alongwith providing minor repairs/ replacement of hose pipe, painting with Fire red colour paint etc. complete as required.
32Rewinding of 0.5 HPmotor complete using suitable gauge copper wire as required
33Rewinding of 1 HPmotor complete using suitable gauge copper wire as required
34Replacement of faulty heating element of geyser complete as required
35Replacement of faulty thermostat of geyser complete as required