}

Tender for Fitment , Installation , Supply , Commissioning And Testing Of Electrical Variable Voltage Variable Frequency Ac Drive., lucknow-Uttar Pradesh

Northern Railway-NR has published Tender for Fitment , Installation , Supply , Commissioning And Testing Of Electrical Variable Voltage Variable Frequency Ac Drive.. Submission Date for this Tender is 03-11-2023. Railway Ancillaries Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

40016156
Tender for Fitment , Installation , Supply , Commissioning And Testing Of Electrical Variable Voltage Variable Frequency Ac Drive.
Open Tender
Indian
Uttar Pradesh
lucknow
03-11-2023

Tender Details

Supply Of Fitment , Installation , Supply , Commissioning And Testing Of Electrical Variable Voltage Variable Frequency Ac Drive.Fitment , Installation , Supply , Commissioning And Testing Of Electrical Variable Voltage Variable Frequency Ac Drive.,Fitment , Installation , Supply , Commissioning And Testing Of Electrical Variable Voltage Variable Frequency Ac Drive Rating 5.5Kw/7.5Hp , 3 Phase , 380-480 V Ac , 50/60 Hz , Dc Power Supply:510-680 V Dc. Nominal Input Current(Nd):17 Amp. Nominal Input Current (Hd) 13 Amp. Output Power Rating (Nd): 7.5 Kw , Output Power Rating (Hd): 5.5 Kw. Frequency Control Range : 0-400 Hz. Motor Power 5.5 Kw/7.5Kw. Emc Filter Class C2 Integrated. Braking Standstill By Dc Injection. Salient Features : Operation Mode Selection. Dc Injection Breaking And Short Circuit Braking , Speed Search, Delay Timer Pid Control, Dwell Function, Energy Saving, Acceleration And Deceleration Times. Slip Compensation , Torque Compensation , Carrier Frequency, Frequency Upper/Lower Limit, Torque Control Jump Frequency. Main Control Function: Torque Control , Drop Control, Speed/Torque Control Switch, Feed Forward Control, Zero Servo Control, Momentary Power, Loss Ride Thru And Speed Search, Over Torque Detection, Torque Limit. Speed Control Range: V/F Control 1:40 , Open Loop Vector Control 1:200 , Open Loop Vector Control Pm 1:20, Close Loop Vector Control For Pm1:1500 , V/F Control With Pg 1:40 , Close Loop Vector Control 1:1500, Advance Open Loop Vector Control For Pm 1:100. Output Overload Tolerance : Nd Rating: 120% Of Rated Output Current For 60S. Hd Rating: 150% Of Rated Output Current For 60S. (Derating May Be Required For Repetitive Loads). Protective Design : Ip00 Open Chassis, Ul Type 1 Enclouer. Ambient Temperature (Open Chassis);10 To +50 Degree Celsius. Standard Compliance: Ul508c , Iec/En61800 , Iec/En61800-5-1, Two Safe Disable Input And Iedm Output According To Iso/En13849-1 Cat3 Pld. Iec/En61508 Sil2.Make - Yaskawa , Schneider , Abb , Si

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail