Tender For Special Repair/Replacement To Certain Living-In Billets At Af Stn Gwalior, gwalior-Madhya Pradesh

Military Engineer Services-MES has published Tender For Special Repair/Replacement To Certain Living-In Billets At Af Stn Gwalior. Submission Date for this Tender is 18-05-2023. Railway Ancillaries Tenders in gwalior Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

36974577
Corrigendum : Tender For Special Repair/Replacement To Certain Living-In Billets At Af Stn Gwalior
Open Tender
Indian
Madhya Pradesh
gwalior
18-05-2023

Tender Details

Special Repair/Replacement To Certain Living-In Billets At Af Stn Gwalior

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Apr-2023 AMD1 Date 26-04-2023
2 19-Apr-2023 AMD2 Date 02-05-2023
3 25-Apr-2023 AMD3 Date 09-05-2023
4 01-May-2023 AMD5 Date 11-05-2023
5 01-May-2023 AMD4 BOQ 11-05-2023
6 11-May-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-05-2023

Key Value

Document Fees
INR 1000 /-
EMD
INR 133615.0 /-
Tender Value
INR 72.42 Lakhs /-

BOQ Items

Name of Work: SPECIAL REPAIR/REPLACEMENT TO CERTAIN LIVING - IN BILLETS AT AF STN GWALIOR
Sl. No. Item Description
1Demolition of plain cement concrete (unreinforced) of any mix / grade inground floor and pavings not exceeding 15cm thickness (below or above ground level) including removal of debris out off the AF station premises / MOD land etc complete all as specified & directed.
2Demolition of plain cement concrete (unreinforced) of any mix / grade, any description and in any position other than ground floor, (for sunken portion ) exceeding15 cm thickness including removal of debris out off the AF station premises / MOD land etc complete all as specified & directed.
3Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, chajjas, staircases, landings and similar suspended work (reinforcement cut as required to facilitate demolition) including removal of debris out off the premises / MOD land complete all as specified & directed.
4Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
5Taking down cement plaster on brick or stone masonry, etc. including raking out joints, hacking for key and scrubbing down with water, etc. complete all as specified and directed.
6Demolition of brickwork of any description and in any position built in cement or cement lime mortar including all quoins, arches, pillars including segregation of serviceable bricks for reuse & removal of rubbish out off the AF station premises / MOD land etc complete all as specified and directed.
7Material and Labour for rendering 10 mm thick in cement mortar (1:6) on fair faces of brickwork or concrete surface, finishedeven and smooth without using extra cement complete all as specified and directed.
8Material and Labour for rendering 15 mm thick in cement mortar (1:4) on fair faces of brickwork / external surface of masonry wall using liquid water proofing compound mixed at 3%by weight of cement, surface finished even and smooth without using extra cement complete all as specified and directed. Note:(i) WPC will be measured and paid separately under respective item of BOQ (ii)) Cost of scaffolding for rendering is including in this item. (iii) Rendering will be done in two layers. Ist layer will be 10-12 mm thick and 2nd layer will be 3-5 mm thick.
9Material and Labour for rendering 5 mm thick in cement mortar (1:3) on concrete surface ofceiling finished even and smooth without using extra cement complete all as specified and directed. Note:-(i) Cost of scaffolding for rendering is including in this item.
10Supply only water proofing compound of approved make completeall as specified and directed.
11Material and Labour for glazed ceramic digitally designed coloured tiles450 mm X 300 mm X 6 to 7 mm thick with highlighter on vertical surface such as skirting / dado etc ,set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles including 10 mm thick rendering in cement mortar (1:4) as backing caot complete all as specified & directed.
12Material and Labour for premium quality non-skid, joint free, digitally designedcoloured ceramic floor tiles 7-8 mm thick (Square/rectangular), area of each tile exceeding0.11 Sqm but not exceeding 0.18 Sqm, in floors, etc. set & jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, over& including 15 mm thick screed bed in cement mortar (1:6) complete all as specified &directed.
13Material and Labour for 18 mm to 20 mm thick Baroda green marble slab of approved type / variety (table rubbed and pre mirror polished)in window cill, jambs, steps and cooking platforms in CM 1:4 including pointing in coloured cement to match with shade of Baroda green marble slab including half moulding of Baroda green marble slab edges over and including 20 mm thick screed bed in CM 1:6 for laying of Baroda green marble slab etc complete all as specified and as directed.
14Material and Labour for machine cut Kotastoneslab 20 to 25mmmm thick in floor over cement screed bed laid and jointedwith grey cement slurry mixed with pigment to match the shade of the slab including and grinding polishing, over and including screed bed 20mm thick in CM 1:6etc complete all as specified and as directed.
15Material and Labour for machine cut Kota stone slab 20 to 25 mm thick asin skirting, risers, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with mirror polish granite finish including backing coat 10 mm thick in CM 1:3 complete all as specified and as directed.
16Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each including builders hardware etc complete all as specified and directed.
17Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 Sqm each etc. including builders hardware etc. complete all as specified and directed.
18Refixing in shutters of any description exc 1.0 sqm and n, exc 2 sqmIn same opening complete all as specified and directed.
19Supply and fix pressed steel frames of size 165mm x60mmfor doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.
20Supply and fix Flush shutters 30 mm thick, solid coreconstruction, with block board core and plywood face panels commercial type on both side and both faces covered with approved pattern with decorative coloured laminate type 1 of 0.9mm thick and all around side faces covered with 10 mm thick 1st classhardwood lipping duly polished complete all as per specified and directed.
21Supply and fix 35mm thick factory made second class hardwood glazed and skeleton door shutter open rebated and prepared to receive glass or gauge, etc. divided into square with plain chamfered or rounded, mitred and rebated sash bars any number complete all as specified and as directed. Note :- Size of member of shutters as specified in SSR Part-I (2009) section 8 clause 8.20 (a).
22M&L for solid PVC door frame of size 50 mm X 47 mm made out of 5 mm extruded 5 mm thickPRELSM PVC Sheet of density 600 kg/cum Manufactured by an ISO 9000: 2015 certified company having pattam width of 50 mm and thickness of 10 mm providing weather sea/Non-woven self adhesive gasket throughout the frame. All three frame lengths reinforced with 19 mm x 19 mm MS Square tube of 19 gauge mitred cut at two corners and joined with 2 nos of 150 mm long brackets of 15 mm x15 mm MS square tube. The door frame shall be fixed to the wall using 80/100mm long MS screws through the frame by using PVC fasteners.A minimum of 4 nos of screws to be provided for each vertical member and minimum 2 nos for horizontal members etc completeall as specified and directed.
23Supply and fix Factory made solid panel PVC door shutter 30 mm thick solid panel PVC (style) consisting of frame made out of M.S tubes 19 gauge thickness and size 19mm x19 mm for stiles and 15mmx15mm for the top and bottom rails MS frame shall have a coat of metalprimer of approved make. MS frame shall be covered with heat moulded (100% LEAD FREE) PLAIN PVC "C" channel made from 5mm thick sheet of density 600kg/cumof size 30mm thickness 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on either side forming stiles and 5 mm thick 95 mm wide PLAIN PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 angle on inner side to form top and bottom and lock rail and 115mm wide PLAIN PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both side to form lock rail Top bottom and lock rail shall be provided either side. An additional 5m thick shall be provided on either side of the panel. An additional 5mm thick PVC strip of 20mm width is to be stuck on the bottom side of the C channel. Paneling of 5mm thick PLAIN PVC sheet to be fitted inside the MS frame welded /seated to the styles and rails with 5mm x 30mm PVC sheet beading on either side and joined together with solvent cement adhesive etc 10mm thick ,20 mm wide cross PVC sheet as gap insert for the top rail & bottom rail.Door to be fixed to frames with 3 nos.MS powder coated butt hinges of size 100mm x25mm x2mm using 32mm long steel screws drilled suitable to pass through both the walls of the MS tubeother hardwares should be fixed with 19mmx6mm size steel screws complete all as per manufactures specification and directed by Engineer – in – Charge.
24Supply and fix stainless steel handle medium weight 125mm size complete all as specified and directed.
25Supply and fix stainless steel handle medium weight 75mm size complete all as specified & directed.
26Supply and fix stainless steel medium weight butt hinges of 100 mm size complete all as specified and directed.
27Supply and fix Stainless steel barrel tower bolts medium weight of of extruded section, 150mm long complete all as specified and directed.
28Supply and fix Stainless steel barrel tower bolts medium weight of of extruded section, 100mm long complete all as specified and directed.
29Supply and fix Stainless steel sliding door bolts 250mm long, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections complete all as specified and directed.
30Supply and fix mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller platecomplete all as specified and directed.
31Supply and fix floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, overall length of cover plate 150mm complete all as specified and directed.
32Supply and fixing of rubber beading door seal 40x 5mm stripin bottom of door complete all as specified and directed.
33Material and Labour for plain cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate ) as in coping on chajja, balcony or in roof Kerbs, benching, coping , bed plates for fixing hold fastbed block ,kerb stone in sides of interlocking tiles , rounded or chamfered on edges and similar work including necessary formwork complete all as specified and directed
34Material and Labourreinforced cement concrete(1:2:4) type B-1 (using 20 mm graded stone aggregate) forslab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves, chajjas, etc and any description and any postion. complete all as specified and directed
35Taking down cement plaster from concrete surfaces including APP membrane complete all as specified and directed.
36Material and Labour for applying acrylic based waterproofing, flexible, liquid applied, single component, weather resistant, acrylic waterproofing membrane for all types of exposed roof slabs (new and old), terraces (sloped and flat), ultra violet rays and heat reflection system having following key performance properties: 1.Acrylic polymer dispersion single component liquid appalled system sika cool coat not less than 650 micron (1.2mm system built up), contains Cross-linking polymers, Special Glass micro fibers, pigments and advanced antifungal additive that provides long lasting tough water proofing membrane conforms to: IS101, IS 2645, EN 1542, ASTM D 5589, ASTM D 5590, ASTM C-1202-08, ASTM D 4587, ASTM C 836, ASTM E1980, EN-673, EN 410.It should have solid content - 66% (by weight), VOC<10 gm/I complies to Green building standards and should meet the properties of Adhesion Strength on cement after 14 days curing > 1.5N/sqmm as per EN E1542, tensile strength 1.5 MPa as per ASTM D 41, crack bridging properties 3.2mm as per ASTM C-836, water absorption (%by mass) < 10% as per ASTM D570, solar reflectance index not less than 100(5%) (low wind to high wind condition), elongation at break (%) 200% as per ASTM D 412, algae & fungal resistance as per ASTM D- 5590, should have a hardness 45 after 1 month and should pass accelerated weathering, 500 hours without any cracking & 100% gloss retention as per ASTMD 4587. 2. Fully reinforced with glass fiber reinforced sika fab 1. 3. The roofing system should be compatible with bitumen system. 4.Side termination bar of 2mm thick aluminium valley strip with one side bending for membrane termination to be used with SBF fasteners. 5. Providing and applying primer over the prepared surface with sika cool coat primer @ coverage: 0.1-0.12 kg/sqm.first coat: sika cool coat consumption @ 0.5 kg/sqm.Reinforcement : sika Fab 1. second coat: sika cool coat consumption @ 0.5kg/sqm. Third coat: sika Cool cat, consumption@ 0.5kg/sqm and Top coat: sika cool coat primer, consumption @0.05-.08kg/sqm all as per specification & direction of the engineer -in -charge. Note : - Contractor may use equivalent chemicals of equivalent makes from latest approved list of E-in-C’s Branch as approved by GE. The work shall be executed by authorized applicators of make approved by E-in-C branch. The contractor have to submit MOU to the GE within 15 days after placing of Work order No1.
37Repairing surface irregularities, damaged concrete, if any, with sikafloor-161 HC or equivalent modified repair mortar including a coat of sikafloor-161-HC priming coat including all material, labour, tools and tackles complete maximum avg upto 10mm. complete all as specified and directed.
38Material and Labour for Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed.
39Material and Labour for 15 mm thick screed bed in cement mortar 1:3 complete mixedwith usingwater proofing compoundas per manufacturers instructionsover roof top surface finished even and smooth using extra cement and application of water proofing treatment using APP modified roof membrane over existing accessible RCC roof slab / chajjah / canopy /sunken portion/ parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying one coat of hot blown bitumin grade 85/25 confirming to IS-702 @ 1.20 kg per Sqmover a coatofbitumen primer @ 0.40 litre / Sqm manufactured by the same agency as that of APP membrane with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.50 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Physical property of membrane shall be as under : (i) Membrane weight not less than 3.50 Kg/Sqm. (ii)Non woven polyester weight not less than 160 gsm/Sqm. (iii)Softening point of membrane not less than 150degree Celsius. (iv)Joint tensile strength-longitudinal not less than 650/Sqcm and transverse not less than 450/sqcm at 230 degree Celsius. (v) Tear strength - longitudinal not less than 300 Nand transverse not less than 250N. (vi)Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not lessthan 3 Kg/Sqcm. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap. (Note:- WPC shall be measured and paid separately)
40Material and Labour for PCC (1:5:10) type E-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified anddirected.
41Material and Labour for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, etc complete all as specified and directed.
42Material and Labour for TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, etc complete all as specified and directed.
43Material and Labour for Formwork to soffits of suspended slabs such as roof slabs floor slabs, landing and similar work not exceeding 200mm thick (Horizontal or Sloping),fair finished surface complete all as specified and directed.
44Material and Labour for 50 mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in plinth protection, floors, pavings, etc., finished even and smooth with using extra cement complete all as specified and directed.
45Supply and fix in repair Stainless Steel fancy type decorated Curtain rod, 20 mm dia complete all as specified and directed.
46Supply and fixin repair 4.00 mm dia Plain mild steel wire galvanised class 3, as in detached work such as for mosquito nets and fixing to straining bolts, hooks eys etc complete all as specified and directed.
47Supply and fix Stainless Steelbrackets having screw for tightening of curtain rod of 20mm dia for fixing of curtain rod, complete all as specified and directed.
48Supply and fix Stainless Steelbright color decorative corner/end cap for Curtain rod of 20mm dia complete all as specified and directed.
49Supply and fix stainless steel peg set of six with base plate and fixed to wall/door with rawal pegs or stainless steel screw complete all as specified and directed.
50Supply and fix shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 300gms) complete all as specified and directed .
51Supply and fix in repair 600 mmx450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC buildg board or commercial plywood and fixed to wooden plugs with CPbrass screws and cup washers complete all as specified and directed.
52Supply and fix in repairBrass chromium plated, tubular towel rails 20 mm dia, D- type, 60 cm long between flanges, completed all as specified and directed.
53Supply and fix in repair brass chromium plated shower roses with swivel joints, 150 mm sizein square with CP long shank arm including fixing to steel pipe or union, complete all as specified and as directed.
54Supply and fix in repairs WC squatting pan " Orissa Pattern" of size 580 X 440 mm white with integral foot rest including PVC P or S trap, front or back inlet and making connection to trap and to flushing cistern and including lime concrete bedding and including S&F of trap set complete all as specified anddirected.
55Supply and fix in repairs PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including dual flush system valve float and handle, PVC flush pipe 32 mm bore and brackets complete set all as specified anddirected.
56Supply and fix in repair vitreous china urinal full stall urinal (back or corner wall type) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to pluges with and including 60mm long brass screws, pointing around urinal back in cement , flush pipe, grating and union for discharge pipe. (Including of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed.
57Material and Labour for Granite (of any type) work, 20 mm thick (Table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms in CM 1:4 andincluding pointing in white cement 1:2, using marble dust with admixture of pigment to match with shade of Granite including half moulding of granite edges including screed bed 20mm thick in CM 1:6 and drilling hole for gas pipe complete all as specified and directed.
58Supply and fix in repair vitreous china wash hand basin, white, flat back, size 600mmx480mm excluding taps, chain and plug and porcelain stopper but including cutting for and pinning in ends of and including brackets, waste pipe and PTMT waste coupling of 32mm dia complete all as specified and directed.
59Supply and fix in repair concealed stop cock fancy type chromium plated with long shank and cup cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both end of size 15 mm bore complete all as specified and directed.
60Supply and fix in repair concealed anglecock, fancy type chromium plated with long shank and cup cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both end of size 15 mm bore complete all as specified and directed.
61Supply and fix in repairs bib tap, cast copper alloy with capstan head, CP fancy type with long body shank, screwed down with high pressure screwed for iron pipe and fixed 15mm bore, complete all as specified and directed.
62Supply and fixin repair 15 mm bore Pillar taps fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered `Hot" or `Cold" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
63Supply and fixPVC connections 15mm size with PTMT nuts of length 600 mm,complete all as specified and as directed.
64Supply and fix Stainless Steel grating doom with hole or without hole, 100mm dia size complete all as specified and directed.
65Dismantlingtanks water tank exc 250 but n exc 500 ltr complete all as specified and directed.
66Disconnecting existing tanks exc 250 and not exc 500 ltr setting aside (or lowering if required) for repair, cleaning etc and hoisting if required reconnecting and re-fixing in position (cleaning repair etc measured separately) complete all as specified and directed.
67Disconnecting existing tanks exc 500 and not exc 1000ltr setting aside (or lowering if required) for repair, cleaning etc and hoisting if required reconnecting and re-fixing in position (cleaning repair etc measured sepretaly) complete all as specified and directed.
68Supply and fix rotational moulded polyethylene water storage tank of capacity 500 ltrs (Cylindrical/vertical with closed type), triple layer construction, ISI marked, hoisted and fixed in position including 20 mmbore GI medium grade over flow ( 450mm long) and washout pipe (600 mmlong ) with fittings, etc complete all as specified and directed.
69Supply and fix 20mm bore dia of pipe Stop valves/Gate valves cast copper alloy screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed. complete all as specified and directed.
70Supply and fix ball/ float valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed 20mm bore minimum weight 210 gms complete all as specified and as directed.
71Supply and fix 15 mm bore dia of pipe Stop valves/Gate valves cast copper alloy screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed. complete all as specified and directed.
72Supply and fix 25mm bore dia of pipe Stop valves/Gate valves cast copper alloy screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed. complete all as specified and directed.
73Dismantling of cast iron or reinforced concrete drain pipe of 75 mm/100 mm bore, jointed in cement mortar by taking out of trenches, if required, complete all as specified anddirected.
74Taking up or down steel water tubing and connections of 15mm bore including cleaning for refixing or removal to store complete all as specified and as directed.
75Taking up or down steel water tubing and connections of 20mm bore including cleaning for refixing or removal to store complete all as specified and as directed.
76Taking up or down steel water tubing and connections of 25mm bore including cleaning for refixing or removal to store complete all as specified and as directed.
77Refixing old20 mm bore GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid infloors in new or old position complete all as specified and directed.
78Refixing old 25 mm bore GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid infloors in new or old position complete all as specified and directed.
79Supply and fix 15 mm bore GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid infloorscomplete all as specified and directed.
80Supply and fix 20 mm bore GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid infloors complete all as specified and directed.
81Supply and fix 25 mm bore GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid infloors complete all as specified and directed.
82S&F 100 mm dia Cast iron spun type soil waste and vent pipes, in any length with or without ears with cement joints, fixed to wall complete all as specified and directed.
83S&F 100mm cast iron sanitary connection socket to fitWC outlet complete all as specified and directed
84S&F in repair 100 mm cast ironvent cowl complete all as specified and directed
85S&F 100mm bore of bends (any radius) diminishing pieces or tapers (larger bore measured ) complete all as specified and directed.
86S&F 100 mm Branch pieces single (equal or unequal ), ordinary or inverted ( spigot or socket type ) or with paralle branches or Tpiece with oval access doors.complete all as specified and directed.
87Supply and fix in repair stack clamps made out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stay to walls or roofs for 100 mm bore pipe etc complete all as specified anddirected.
88Supply and fix in repair stack clamps made out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stay to walls or roofs for 75 mm bore pipe etc complete all as specified anddirected.
89S&F in repair 75mm dia Cast iron spun type pipe , in any length with or without ears with cement joints, fixed to wall complete all as specified and directed.
90S&F 75mm bore of bends (any radius) diminishing pieces or tapers ( larger bore measured ) with oval access door with cement joint complete all as specified and directed.
91S&F 75mm bore of bends (any radius ) diminishing pieces or tapers ( larger bore measured ) with cement joint complete all as specified and directed
92S&F 75 mmbore of pipe Branch pieces single (equal or unequal ), ordinary or inverted ( spigot or socket type ) or with parallel branches or Tpiece with oval access doorswith cement joint complete all as specified and directed.
93S&F in repair 75mm dia cast iron Nahani trap including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4 ) complete all as specified and directed.
94S&F in repair 100mm dia cast iron Nahani trap including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4 ) complete all as specified and directed.
95S&F in repair 75mm dia cast iron floor trapincluding jointing to waste pipe fixed in cement concrete type B-1 (1:2:4 ) complete all as specified and directed.
96S&F 75mm dia cast iron gully trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4 ) complete all as specified and directed.
97M&L for Providing cement concretetype B-0 1:2:4 (using 12.5mm graded stone aggregate) as in coping on chajja,balcony or in roof kerbs, filling of steelpressed chowkat, rounded or chamfered on edges and similar work complete all as specified.
98Material and Labour for preparation of new plaster surfaces of walls and applying two coats of oil bound distemper over one coat of primer complete all as specified and directed by Engg-in-Charge.
99Material and Labour for complete removal of existing treatment on wall surface and applying two coats of oil bound distemper over one coat of primer including preparation of surface complete all as specified and directed by Engg-in-Charge.
100M&L for preparation of new steel Surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
101M&L for preparation of new steel Surfaces of any description, not exc. 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
102M&L for preparation of new woodenSurfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
103M&L for preparation of oldwoodenSurfaces of any description, over 10cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
104M&L for preparing new plaster surface of ceiling and applying two coats of white washover coat of primer complete all as specified and directed.
105M&L for complete removal of existing treatment on ceiling surface and applying two coats of White wash over a coat primer complete all as specified and directed.
106Material and Labour brickwork with sub-class "B" bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4complete all as specified and directed.
107Material and Labour for mild steel framedwork such as grills, grating etc with ends of bars shouldered and or riveted into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, cooler platform, frame work of water tanks and similar work including welding conforming to Fe-290 & grade E-165etc complete all specified and directed
108Material and Labour for Roof tiles mangalor pattern interlocking at side joints over screed bed or bedding layer of mortar 20mm thick with cement mortar 1:4 for laying floor finish with & includingwater proofing compound as per manufacturing instructions etc complete all as specified and directed.
109Material and Labour for Writing letters or figures (Block, Roman, Italic or Indian) n exc. 30 cm high complete all as specified and directed.
110Material and Labour for removing loose and broken concrete by chiselling /picking etc upto a depth of 80 to 100 mm from columns, beams and similar structural members cutting edges cleaning the dismantled portion with wire brushes etc to remove dust, dirt and other foreign particles etc and washing with clean water with pressure and removal of debries to a distance not exc 50 m all as specified and directed by Engr-in-Charge, including necessary scaffolding etc complete.
111Material and Labour for removing loose and broken concrete by chiselling /picking etc upto a depth of 10 to 20 mm from floor/roof slab/chajjasand similar structural members cleaning the dismantled portion with wire brushes etc to remove dust, dirt and other foreign particles etc and washing with clean water with pressure and removal of debries to a distance not exc 50 m all as specified and directed by Engr-in-Charge, including necessary scaffolding etc complete.
112Material and Labour for mild steelTMT bars 08 mm dia and over grade Fe -500 , asin stirrups, spacers & binders, cut to length, bent to shape required, including cranking bending spirally for hooping for column, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed.
113Material and Labour for applying one coat of anti corrosive primer @ 0.25 Litre/Sqm for the steel area to exposed old and new reinforcement to the full circumference and length of bars to form unbroken 40 Micron thick film all as specified and directed by Engr-in-Charge.
114Material and Labour for applying one coat epoxy bonding agent @ 2.6 sqm/litre oras per manufacturer"s instruction to old concrete surfaces all as specified and directed by Engr-in-Charge to surfaces of columns, beams and similar structural members all as specified and directed.
115Material and Labour for non shrink, cementitous micro concrete mixed with 12.5 graded stone aggregate using Renderoc RG or equivalent by weight (18 Kg Aggregate :25 Kg Renderoc RG) respectively (as per manufactures instruction) laid in average thickness 80 to 100 mm in surfaces of columns, beams and similar structural members including use and waste of water tight form work to facilitate pouring of micro concrete all as specified and directed by Engr -in -Charge.
116Material and Labour for spraying curing compound as per manufactures instruction on freshly cast concrete surfaces all as specified
117Material and Labour for application of high build polymer cement sand mortar 1:3 with water cement ratio 0.35 to 0.45 mixing with Nito bond SBR @ 5 ltrs per 50 Kg cement on ceiling / chajja surfaces 10 to 20mm thick in two layers over slurry priming coat of 1 volume Nito bond SBRto 1 volume water, 3 volume fresh cement (5 sqm per litre Nito Bond SBR) etc all as per manufacturers instructions, including painting/finishing to match with the existing complete all as specified and as directed by Engineer-in-Charge.
118Supply and fix in repair 110 mm bore PVC (SWR) Soil/waste and vent pipe in any length single socketed with rubber ring joints fixed to wall, laid under floor etc complete all as specified and directed.
119Supply and fix Cast iron pipesbends any radius 100 mm borewith ducks foot or heel rest complete all as specified and directed.
120Material and Labourfor cement concrete 40 mm thick 1:2:4 type B-1 laid in panelover existing concrete surfacesas in floor to raised to avoid water logging in two wheeler parking complete all as specified and directed.
121Supply and fix aluminium dividing strips 38 mm wide 1.5 mm thicklaid in panel as in floor complete all as specified and directed.
122Excavation in trenches in soft and loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soil including forming bottom surface to required slope/gradient forlaying cables/pipes etc., if required,complete all as specified and directed by Engineer-in-Charge.
123Material and Labour for 75 mm thick PCC 1:4:8 type D-2 (using 40mm graded stone agg) as in sub base, base, floors, pavings, etc. complete all as specified and directed.
124Material and Labour for brick work with old size sub class "B" bricks built in cement mortar 1:4 straight or curved on plan exceeding 6.0 mean radiuscomplete all as specified and directed.
125Material and Labour for rendering 15mm thick in cement mortar (1:4) on brickwork finished even and smoothwithout using extra cement complete all as specified and directed by Engineer-in-Charge.
126Returning, filling in including spreading, levelling, watering and well ramming in layers of25 cm thickafter the cables etc. are laid, jointed & tested complete all as specified and directed by Engineer-in-Charge.
127Removing of excavated materialexc.250m but n exc 500m, deposited where directed. complete all as specified and directed by Engineer-in-Charge.
128Material and Labour forone coat of grinding of kota stone existingold flooring including cutting if necessary complete all as specified and directed by Engineer-in-Charge.
129Supply and fix powder coated (of approved tint) aluminum frame & openable shutter for door, window, ventilators including joining cleat glazing clip, snap beading, rubber packing, building hardware & screw etc for fixing complete all as specified & directed. Note : (i) wire mesh, sheet glass and beading shall be measured and paid separately under respective items. (ii)Weight of only aluminium section used for fabrication of door/window shall be measured for payment.
130Supply and fix stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples etc complete all as specified & directed.
131Supply and fix 4.0 mm thick sheet glass, ordinary quality in square/ rectangular, not exceeding 0.5 Sqm in each pane complete all as specified & as directed.
132Supply and fix 4.0 mm thick frosted glass pin headed type in squares/ rectangularnot exceeding 0.5 Sqm ineach pane complete etc complete all as specified & directed.
133Supply only beading for fixing of glass pane to aluminium window complete all specified and directed. Note : fixing charges already included in separate item
134Material and Labour for3mm thick cementitious wall careputty on new/old plasterfor internal/external wall surfaces complete all as specified and directed.
135Material and Labour for3mm thick cementitious wall careputty on new/ old plaster for internalceiling wall surfacescomplete all as specified and directed.
136Material and Labour for complete removal of existing treatment on ceiling surface and applying two coat of oil bound distemper over a coat primer complete all as specified and directed.
137Material and Labour for complete removal of existing treatment applyingtwo or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm / liter and UV resistance as per IS15489:2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre /10sqm over and including priming coat of exterior primer applied @0.90 litre/10 sqm over old surfaces complete allas specified and directed.
138Material and Labour for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm / liter and UV resistance as per IS15489:2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre /10sqm over and including priming coat of exterior primer applied @0.90 litre/10 sqm over new surfaces complete allas specified and directed.
139Material and Labour for Sand filling under floor including watering and consolidation complete all as specified and directed.
140Material and Labour for60mm thick rubber moulded glosy finished inter locking paver block with grey cement and pigment of any type and shape the minimum compressive strength not less then 350 kg/Sqcm as approvedcomplete all as specified and directeded.
141Material and Labour for Reinforced concrete pipes class NP-3 300 mm Bore laid and jointed complete with collar (for road crossing) complete all as specified and directed.
142Material and Labour for cement concrete (1:3:6) type C-2 (using 40mm gradedcrushed stone aggregate) as in concrete bed to drain pipe including packing under and haunching against the sides of pipe after they are laid and tested complete for pipe of 300mm bore complete all as specified and directed.
143Material and Labour for PCC 1:2:4, type B1 using 20mm graded crushed stone aggregate as in surface channel and drain in foundation filling and mass concrete complete all as specified and directed.
144Material and Labourfor Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, including forms, moulds, etc (inner girth only to be measured) complete all as specified and directed.
145Cleaning of firstmanholes of any description and in any position depth n’exc 1.5mtr deep mechanically or manually by taking off sludge waste/ night soil and silted soil from the existing manhole of any size, collecting and removalof sludge in sealed containerout side Air Force boundary and disposalof the samecomplete all as specified and directed
146Demolition and breaking up rain water pipes (SGSW, AC or RCC) of internal dia 150 mm, set in cement mortar including removal of debris out off the AF station premises / MOD land complete all as specified and directed.
147M&L for 100mm Cast iron soil, waste pipes spun type , in any length with or without ears with cement joints, laid in trenches or in floors complete all as specified and directed.
148Material and Labour for reinforced concrete pipes, class NP-3, 150 mm bore, laid and jointed in cement mortar 1:1with collars and tested complete all as specified & directed.
149Material and Labour for cement concrete (1:3:6) type C-2 (using 40mm gradedcrushed stone aggregate) as in concrete bed to drain pipe including packing under and haunching against the sides of pipe after they are laid and tested complete for pipe of 100mm bore complete all as specified & directed.
150Material and Labour for cement concrete (1:3:6) type C-2 (using 40mm gradedcrushed stone aggregate) as in concrete bed to drain pipe including packing under and haunching against the sides of pipe after they are laid and tested complete for pipe of 150mm bore complete all as specified & directed.
151Cutting into existing manholes for connecting new drains of internal dia of pipe150mm making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required
152Cutting into existing manholes for connecting new drains of internal dia of pipe100mm making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required
153Material and Labour forPCC (1:4:8) type D-2, (using 40 mm graded stone aggregate ) as in foundation filling and mass concrete complete all as specified & directed.
154Material and Labour providing Precast Cement concrete (1:2:4) type B-1, ( 20 mm graded aggregate ) as in cover slab (for manholes, drain etc)set in cement mortar (1:4) complete all as specified and directed.
155Taking down carefully existing unserviceable copper/ aluminium point wiring of any description & in any position with and includingpvc/steel conduit all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings call bell, lamp holders etc and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed. Note: Old fittings/fixtures/accessories like switch, sockets, lamp holders, regulators light fittings etc found in serviceable condition shall be removed carefully for reuse in the work and shall be paid for separately under appropriate item of Schedule `A’.
156Material and labour for point wiring for one light /fan/Exhaust fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable FRLSH,1100 volts grade in and including concealed PVC conduits (Medium grade) of size not less than 20 mm dia all as directed with sunken type pressed steel terminal box and junction boxes 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with laminated top sheet of 3 mm thick for housing of switches, sockets, regulators etc including all accessories andusing 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed. Note :-(I) The portion of point wiring at ceiling shall be in surface PVC conduit/ casing & capping of suitable size fixed on ceiling surface with using PVC rawl plugs. (ii)Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A". (iii) The quoted rates shall be deemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thicklaminated sheet fixed with suitable brass screws and cup washers.
157All as per item No 2.57 here-in-before but point wiring for 5 pin switch socket outlet combination, 5/6 Amps on independent board complete all as specified and directed.
158All as per item No 2.57 here-in-before but Point wiring for 5 pin socket ,6 Amps on same board complete all as specified and directed.
159Material and labour for point wiring for one 6 pin Socket 15Amp with using 2.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable FRLSH,1100 volts grade in and including concealed PVC conduits (Medium grade) of size not less than 20 mm dia all as directed with sunken type pressed steel terminal box and junction boxes 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with phenol bonded polycarbonate top sheet of for housing of switches, sockets, regulators etc including all accessories andearth continuity conductor using 2.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed. NOTE :-(I) The portion of point wiring at ceiling shall be in surface PVC conduit/ casing & capping of suitable size fixed on ceiling surface with using PVC rawl plugs. (ii)Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A". (iii) The quoted rates shall be deemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thicklaminated sheet fixed with suitable brass screws and cup washers.
160All as per item No 2.60 here-in-before but Point wiring for One light point controlled by two way switch complete all as specified and directed.
161Supply and fix switch piano, flush type, single pole, two way 16 amps 240 voltISI marked white ivory finish complete all as specified and directed.
162Supply and fix switch piano, flush type, single pole, one way 6 amps 230 voltISI marked white ivory finish complete all as specified and directed.
163Supply and fix socket outlet, three pin, 5/6 Amps flush type, 230 volts ACISI marked white ivory finish complete all as specified and directed.
164Supply and fix switch socket outlet combination multi purpose, 2 in 1 pin ,5/6 Ampsflush type, 230 volts AC circuit ISI marked with indicator complete all as specified and directed.
165Supply and fix switch socket outlet combination multi purpose, 5 in 1 pin 16 Ampsflush type, 230 volts AC circuit ISI marked with indicator complete all as specified and directed.
166Supply and fix ceiling rose, surface bakelite 18 mm X 50 mm AC, 230 V polycarbonate isolated body , two or three terminals complete all as specified and directed.
167Supply and fix lamp holder PVC/Polycarbonate type with cord grip cap/back plate suitable for batten/angle /pendent fittingcomplete all as specified and directed.
168Supply and fix fan regulator electronic, step type hum free, socket type, suitable for ceiling fans of any capacity, pre wired 230 volts AC 50 HZ supply 100/120 Watt complete all as specified & as directed
169Supply & Fix for decorative slim linear LED tube light fitting batten type 01x20 watt light with co extruded polycarbonate body, environmental friendly, energy efficient ready to use pack with all accessories and connecting the same to ceiling rose with using copper conductor 24/0.20 flexible PVC sheathed and fixing arrangement for fixing the light fitting to wall/ roof surface complete all as specified & directed by Engineer in-charge
170Supply and fixStreet/Security light fittings 1X35W new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP-66 roadway luminaire with high power LED as light source with acrylic cover suitable for pole dia40mm(max) with complete (40 mm dia GI pipe light grade ),clamp,nut-bolt and washers all directed by Engineer-in-Charge.
171Disconnecting & taking up or down existing unserviceable MCB DB VTPNwith all MCB"s/Isolator & metal clad box of any description and in any position with existing fittings (MCB"s) complete all as specified & as directed.
172Supply and fixing of sheet metal enclosure Double door for DB’s8 way 240 Volts with 200 Amps rated bus bar for single phase and neutral supply complete fixed properly on in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires all as directed.
173Supply and fixing of sheet metal enclosure Double door for DB’s4 way 240 Volts with 200 Amps rated bus bar for TPN supply complete fixed properly on in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires all as directed.
174Dismaintling & Taking outMCB"s/Isolator/MCCB any size , any type and capacity omplete all as specified and directed.
175Supply and fix MCB SP 6 to 32 Amps ("B" Series) having current rating 10 kA, 240 Vcomplete all as specified and as directed.
176Supply and fix MCB SPN 40 to 63 Amps ("B" Series) having current rating 10 kA,240 V complete all as specified and as directed.
177Supply and fix MCB SPN 63 to 100 Amps ("B" Series) having current rating 10 kA,240 V complete all as specified and as directed.
178Disconnecting & taking up or down u/s submain wiring of aluminium/copper conductor with two run of single core earth cable of any description, any size & in any position including taking out existing conduits of any description and making good the distrubed surface to existing surfaces complete all as specified and directed. Note:- Two run of single core PVC cable with one run of earth conductor shall be measured as one unit)
179Material and Labour for surface/concealed sub main wiring as required with two single core FRLSH PVC insulated and unsheathed copper stranded conductor of size 4 Sqmm 1100 Volts and one run of copper stranded conductor of size 4 Sqmm for continuous earthing drawn in and including rigid non metallic PVC conduit pipe ISI marked of size not less than 25 mm dia including to connect their incoming/outgoing electric connections by using required sizes of lugs/thimbles as well as flexible conduit of suitable sizes shall also be used at any open surfaces of conductor complete all as specified and directed. Note :-(i) Two single core cable and one run of earth copper conductor will be measured and paid as one unit length. (ii).The quoted rate shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc of any description for concealing the conduits to required depth and making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. (iii) Colour coding of wire should be followed as per IS.
180Material and Labour for surface/concealed sub main wiring as required with two single core FRLSH PVC insulated and unsheathed copper stranded conductor of size 6 Sqmm 1100 Volts and one run of copper stranded conductor of size 6 Sqmm for continuous earthing drawn in and including rigid non metallic PVC conduit pipe ISI marked of size not less than 25 mm dia including to connect their incoming/outgoing electric connections by using required sizes of lugs/thimbles as well as flexible conduit of suitable sizes shall also be used at any open surfaces of conductor complete all as specified and directed. Note :-(i) Two single core cable and one run of earth copper conductor will be measured and paid as one unit length. (ii).The quoted rate shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc of any description for concealing the conduits to required depth and making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. (iii) Colour coding of wire should be followed as per IS.
181Material and Labour for surface/concealed sub main wiring as required with two single core FRLSH PVC insulated and unsheathed copper stranded conductor of size 10 Sqmm 1100 Volts and one run of copper stranded conductor of size 10 Sqmm for continuous earthing drawn in and including rigid non metallic PVC conduit pipe ISI marked of size not less than 25 mm dia including to connect their incoming/outgoing electric connections by using required sizes of lugs/thimbles as well as flexible conduit of suitable sizes shall also be used at any open surfaces of conductor complete all as specified and directed. Note :-(i) Two single corecable and one run of earth copper conductor will be measured and paid as one unit length. (ii).The quoted rate shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc of any description for concealing the conduits to required depth and making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. (iii) Colour coding of wire should be followed as per IS.
182Material and Labour for single pole and neutral enclosure with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB of rating 20 Amps, 240 Volts complete fixed on wall by provisioning of suitable size of MS strip, nuts, bolt and washer including taking down existing two pin and earth plug and socket complete complete all as specified and as directed.
183Taking down carefully from existing place forceiling fan/ Exhaustfan and removing to MES store yard Scraping, cleaning & painting with two coats of super enamelled paints (as approved by GE) greasing/oiling and refixing at site complete incl electric connection withthree core flexible wire 1.5 sqmm all as specified and directed by Engineer-in-Charge.
184Taking down carefully from existing place for re use geyser by disconnecting elect /water supply connection and refixing the same after civil work incl all elect /water supply connection connecting with suitable wire all as specified and directed by Engineer-in-Charge.
185Material and Labour for Earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in theground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground levelconnected to galvanized iron wire 4mm diaas earth leadby means of bolts, nuts and washers of GIup to test point, GI tubing20 mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal, magnesium, salt etc& 50mm thick pre-cast RCC (1:2:4) type B-1 (Nominal mix) cover withreinforced with 8 mm dia TMT bar @100 mm centre to centre both ways with mild steel handle 12 mm dia, plastering 12 mm thick in cement mortar (1:6) internally and upto 150 mm below ground level externally with suitable steel handle and angle iron 40X40X6mm frame and chamber of PCC (1:3:6) type C-1 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, includingtaking down of existing earthing complete all as directed. Notes: 1.Earth lead & protection pipes length upto & including 7.50 metre. 2.Earth filling shall be done by vegetable soil. 3.Soil should be free from stone, boulders, aggregate, gravels etc.
186Supply and fix exhuast fan, steel body AC single phase 230v of size 450mm sweep heavy duty with blade, frame and louversall complete all as specified and directed.
187Supply, Installation ,commissioning of water cooler fully stainless steel,electric driven single phase having approx storage and nominal cooling capacity of 40/80 Ltrs complete all as specified and directed.
Disclaimer :