Central Electronics Limited-CEL has published Tender For Provision Of Ssdac/Msdac In Lieu Of Overaged Universal Axle Counters Between Be-Spn Section Of Moradabad Division. Submission Date for this Tender is 19-04-2023. Railway Ancillaries Tenders in Ghaziabad Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 06-Apr-2023 | Corrigendum l | Date | 13-04-2023 |
2 | 13-Apr-2023 | Corrigendum ll | Date | 18-04-2023 |
3 | 18-Apr-2023 | Corrigendum III | Date | 19-04-2023 |
Sl. No. | Item Description |
1 | Supply of terminal block M-6 (ARA terminal-25mm) as per IRS Spec. No.IRS-S-75/91 (Or latest) & IRS Drg. NO.SA-23741/A (ALT.4) or latest. This meterial will be procured by RDSO approved firm and inspected by RDSO. |
2 | Supply of single app.case steel RE with "E" type lock and key ward no.42 and handle as per drg. No. sketch no.RE/S&T/ALD/SK/219/82 and 221/82 with Alt.B.. Inspection by Consignee.. |
3 | Supply of Half app.case steel RE with "E" type lock and key ward no.42 and handle as per drg. No. sketch no.RE/S&T/ALD/SK/219/82 and 221/82 with Alt.B. Inspection by consignee |
4 | Drillbitsize7.14/14mmHSSparallelshanktwist drill(jobberseries.)make-Addison,IT.Rateis inclusive of GST as applicable. Inspection by consignee. |
5 | SupplyofDigitalinsulationTester(Megger) 100V/500V,Motwani,Philipsorequivalentmake. Inspection by consignee. |
6 | Self propelled motorized rail drilling machine suitable for 52KG/60KG rail and comptible for drilling 7.1 mm to 32 mm diameter holes. accepted make: roshan. Inspection by consignee. |
7 | Digitalearthtester 4Terminal,range0-10/100 ohm withNi-cdrechargeablebatterywith accessories kit and other required accessories TEC spec no.GR/TIE-10-April or latest(Inspection: Consignee) |
8 | Supply of maintenance mechanical tool kit which includes: - (a) Hammer hand medium (500 gms) = 01 Nos , (b) Goti Handle 12" socket = 01 Nos , (c) Socket in goti 19 mm= 01 Nos ,(d) Socket in goti 30 mm= 01 Nos ,(e) Socket in goti 16 mm= 01 Nos ,(f) Socket in goti 13 mm = 01 Nos ,(g) Socket in goti 10 mm = 01 Nos ,(h) Wire cutter 6" = 01 Nos ,(i) Nose plier 6" = 01 Nos , (j) Screw driver 6" = 01 Nos , (k) Plier electric 6" = 01 Nos , (l) Screw driverkit(6PC)= 01Nos,(m) SpannerD/E (30x32)= 01Nos,(n)SpannerD/E (17x19)= 01Nos,(o) Spanner D/E (32x36) = 01 Nos , (p) Spanner S/E (45) = 01 Nos , (q) Adjustable Key (12-300mm)= 01 Nos , (r) Screw Driver 16"= 01 Nos . All the items should be of reputed make Tapiria , Pie or similar or better. Inspection by consignee. |
9 | Supply of Electric tool kit which include:- (a) Spanner D/E round end 8 key set (6x22) = 01 Nos , (b) Spanner D/E open end 8 key set (6x22) = 02 Nos , (c) Plier electric 8" = 01 Nos (d) Plier electric 7" = 01 Nos (e) Wire cutter stipper = 01 Nos , (f) Screw driver 12"= 01 Nos , (g) Hammer (500 gm) = 01 Nos , (h) Soldering iron = 01 Nos. All the items should be of reputed make Tapiria , Pie or similar or better. Inspection by consignee. |
10 | SupplyofwiringmaterialasperIRSSpec No.IRS-S76/89withamendmentNo.3orlatest dulyinspected by RDSO, Copperwire PVC sheated & PVC insulated sizes as under: Indoorcable of 40x1 mm. Inspection by RDSO |
11 | SupplyofTDRBasedcablefaultlocatorfor metaliccablesVizLVPowercable/Control cables/Signalling cables fault location capability 15 km (45000ft) accuracy: Plus/minus 3 ft at 10,000 ft. One step step configurable for any cable type and VP (0.300 to 1000) measures distance to fault in feet meter or time , two pair test capability , Automatic instrument control mode, splash and drip proof, pair comparison mode, splits/coss talk lit display , input protection plus/minus 200 VDC Plus peak AC to a maximum of 440 Hz, battery operated , including :Test loads (Min 2 pair) carrying case battery use manual & free demo at consignee premises model TS 90of Tempo(Stanley)orsimilarofmake/Greenless/ Megger(InspectionbyRITES)Make/Brand-Asper enclosed technical compliance. |
12 | Supply of SM/SI/ESM furniture of Godrej or similar make consisting of the following:- 1. Executive revolvingbearingseries low back floatingchairwith normal arms cushionedchair:1no. 2. Executivetable size 72"x36"x30" with 3 drawers one side, Lockers cabinet on otherside:1 no. 3. Visitors chair seat & back cushion with high density foam with plastic PVC handle capsul type flat pipe duly painted black: 3 nos. 4. Almirah steel with locking arrangement size 1277mmx765mmx440mm=1no. Inspection by consignee. |
13 | SupplyofPCfor fault diagonstic (minimum configuration:I-5orbetter orsimilarwithlatest cofiguration. Inspection by consignee. |
14 | Supplyoflaserprintermake HP/CANON/SAMSUNG/XEROXHP1020plus MonochromeLaser printer or better or similar. |
15 | Supply of disconnect terminal Wago or similar as per spec. no.RDSO/SPN/189/2004 Ver 3.0 or latest as below |
16 | 2-Conductordisconnectterminalblock;Screwless type2 terminal(1IN-1OUT)Disconnectingtype TerminalBlock : 0.2to2.5sq.mm400V/16A, centremarkingwithtesting facility.color- Grey. Inspection : RITES |
17 | Endandintermediateplate,2mm/0.079inthick greyOR Separatorplate2mmthickoversized, orangeaspersite engineer. Inspection : RITE |
18 | Screw less End stop, 10mm/0.39 in wide, carrier rail Din 35, Grey. Inspection : RITES |
19 | Steel carrier Rail, 35x7.5mm, 1 mm/0.039 in thick, unslotted (1mtr length). Inspection : consignee |
20 | Supply & Installation of Thermo shrink jointing kit for 6-Quad cable for straight through joints as per IRS: TC-77/2010(Rev.2)withlatestamendments. procuredthroughRDSOapprovedvendor inspectionby consignee . |
21 | Supply of Auto battery charger input 230V AC output 24V DC, 40//60Amp. For signalling purpose to IRS-S- 86-2000, with amendment no. 4 or latest. Inspection by RDSO. |
22 | Supply of non detoriating type low voltage cartridge fuse rated current 2 Amp/4Amp round head tpe as per spec. No. IRS : S-78/92 with latest amendments. Inspection by RDSO |
23 | Supply of electric fuse complete with fuse block made of PBT for Railay signaling as per IRS-S-75 /2006 Rev. 2 or latest fuse non -deteriorating type low voltage to suit specification no. IRS. S-78/92 or latest Fuse 2/4/10/16 Amp, fuses . Fuse block shall be suitable for round head type fuse. INsp. RDSO. |
24 | Supply&testingofhanddrillmachine(cycletype) suitableformakingholesinrails.Contractor should get the approval of sample from railway engineer. Inspection by consg. |
25 | Supply of Hydrometre, Exide make or similar for measuring specific gravity of battery graded acid with mountingstansdinlocationboxes.Consignee inspectionundermanufacturercertificate( Inspectionby Consignee) |
26 | RELAY,PLUGINTYPE,STYLE "QL1", MAGNETICALLY LATCHED,NEUTRALLINE,24V DC, 11F/4B,CONTACTS,FRONT&BACK CONTACTSMETALTOCARBON,COMPLETE WITHPLUGBOARD, RETAINING CLIP AND CONNECTORS CONFORMING TO BRS:935A, IRS:S-34 & IRS:S-23 (AMENTMEND UP TODATE ASAPPLICABLE).THEINTERLOCKINGCODE FORTHISUNITSHALLBEABDEG.Inspection by RDSO |
27 | Concretingunschduleditemsinconcreteof1:3:6 ratioincement,coarsesandandaggregate 25mm at different places in the yard and plastering top in fine plaster of 1:4 cement sand ratio. It also includes the excavation of earth as required at site and as per instruction of site incharge. The volume in cubic meters shall include the volume occupied by any CI foundation, trstle, MS angle or flat or GI pipe required to be embedded in the casting, Cement coarse sand and aggregate 25mm are to be supplied by the contractor |
28 | Supply of G.I. pipe 50mm dia and fixing on wall tunnel/culverts/ bridges(suitably concreted at both ends)asperspecification&instructionofRailway Engineeratsite.ClampsofM.S.flatsboltsand nut, tobe suppliedbythecontractorandpipes shouldbefixedbyclampsataverage1meter intervals.(Inspectionby Consignee) |
29 | Terminationofallthecoresofalltypeofoutdoor cableafteritslayingonbothend.Thisalso includes preparation of test report for core to core & core to earth on prescribed Performa for each core of the cable separately. This also includes dressing & lacing of cables on both ends. Performa for testing & material for lacing to be supplied by the contractor. |
30 | Boring& Trenchlesscablingalongwithsupply& insertionofHDPE SelfLubricatedpipesasper spec IS 4984 : 1995 with latest amendt material grade PE 63 110 mm dia with minimum 6mm wall thickness in the bore for laying of Signaling / Telecom /Power cable under track/road/culvert etc. cable laying covered separately. Inspection by consignee. |
31 | Laying of signalling/Telecom/power cables of different sizes as per drg. No.(NR/S&T/CON/1. 1/97) and as per cable route plan approved by Railways and meggering of cable before and after its laying of all type of outdoor cables. Meggering to be done for each drum seprately. Meggering sheets to be supplied and filled up by contractor and submitted to railway |
32 | Excavating and refilling of trench in Normal Soil to the level of ground with rammed earth as per drg. No.(NR/S&T/CON/1.1/97-A)soasnottoforma drain0.3Mtrs.Wide& 1Mtr.Deep on bothside ofthe station alongside the track. It shall conform to the safe distance as per signalling and cable route plan in all type of soil,Italsoincludesclearanceofroutesoftrees&bushes.Lesserdepthdueto siteconditionshallbepaid proportionately only after taking permission from atleast JAG officer. |
33 | Excavating & refilling of trench 0.3 Mts wide & 0.8 Mts deep on pitched/Stone/bricks paved surface, road crossing/plateform etc. and restoring the surface to its original conditions. Lesser depth due to site condition shall be paid proportionately only after taking permission from atleast JAG officer. |
34 | Casting, concreting and curing of foundation and erection of App. Cases (Single) as per drg. No. (NR/S&T/CON/2. 7/97). All materials such as cement, sand, aggregate and anchor bolts shall be supplied by the contractor. App. Case single will be supplied by railway. Contractor is required to execute all type of repair works of foundations if required during inserting the cable for termination. |
35 | Casting,concretingandcuringoffoundationand erectionofApp.Cases(Half)asperdrg.No. (NR/S&T/CON/2.7/97). All materials such as cement, sand, aggregate and anchor bolts shall be supplied by the contractor. App. Case single will be supplied by railways. Contracor is required to execute all type of repair works of foundations if required during inserting the cable for termination. |
36 | Preparation& fixingofbakelitehylumsheet 910x800x6mmandbakeliteshelf900x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts & bolts. Fixing of fuses, ARA terminal, plug in type Q series relays and other type relays on square bars fixing and jamming of cableswith2inchthick salwoodplankprovidedatthebottom.Thiswill includeopening,pastingandjamming armour of each cable in the hole drilled separately for each cable through the wood plank & all cable entry point on location boxes, location huts. JB"s relay room/battery room to be closed with suitable masonry works covered with sand and plastering. Description for terminal drawing of circuits, inside app. Case. painting from outside as will inside with red oxide and aluminiumpaint is covered separately. Size of lettering will be 100 mmoras per instructions of Engineer at site. All material including bakelite shilf, hylum board, wood plank, angle iron square bar,wire andwiringmaterialaspertheIRSspecn.nuts andboltsandotheritemsshallbesuppliedby the contractor.Relays.ARA terminals & fuseonly shall besuppliedby therailway.App.casesingle notinvolving wiring of relays |
37 | Provision, preparation & fixing of Bakelite hylumsheet 450 x 600 x 6 mm. Hylumboard shall be fixed on angle iron frame of 25 mm x 25 mm x 3 mm. Angle iron frame will be fixed in location box secured by nuts & bolts. This includes fixing of fuses, ARA terminalsfixing & jamming of cable with 2 inches salwood plank providedatthebottom.i)Thisincludesopening, passing&jammingarmourofeachcableinthe holedrilled separately for each cable through salwood plank & all cable entering points on location boxes, location huts, JBs, relayroom/batteryroomtobe closedwithsuitablemasonryworkscoveredwith sandandplastering,wiring description of terminals, drawing of circuits inside app. case. Painting from inside as well as outside with red oxide & Aluminum paint is covered separately. Size of lettering to be 100 mm& as perthe engineer"s instruction. All materials suchasteakwoodshelf,hylumboard,salwood plank,angleiron,squarebar,NDT/HRC fuse bases, nuts & bolts etc. shall be supplied by the contractor. ARA terminal will be supplied by the Railway.App. Case half not involving wiring of relays |
38 | Supply & burying of earth electrodes pipe of 3 meter length and 50 mm dia pointed on lower end by tapering foralengthof150mmasperDrg No.NR/S&T/CON/6.3/97andconnectingwith lightningarresteror signalling gears as per standard practices. The item includes digging of pit in earth 3 meter deep & fixing earth electrode pipe in it. Earth pipe shall be buried to about the length of 2.7 Mts after welding 6 SWG wire at the lower endandfixing throughnut& boltatthetop.Thisincludescasting ofcementconcreteenclosuresasperDrg. No.NR/S&T/CON/6.4/97. The enclosure is to be plaster on all sides with cement & sand mixture of 1:4 ratio. The soiltreatmentshallbedoneasper standardpractices.Theitemincludesprovisionof earthleadwiresand soldering of lead wires. The other end of the earth wire to be connected to block instruments/cable sheath/power equipment/apparatus case/ relay racks or any other equipment as per the instructions of site Engineer & as per IRSEM. The earth resistance should be less then 1 ohm. Inspection by Consignee. |
39 | Transportation of signalling materials by Road as per instructions of the railway representative at site. Thework alsoincludes loadingandunloading of thematerials. Transporatationmorethan100 Kms.(This item is for loading, leading & unloading of material from other division) |
40 | SupplyInstallationandcommissioningof maintenancefreeearthingsystemwhichconsists of supply ofearthingkit-1setconsistingof(1) EarthElectrodes ofcoppercladsteel alloy of10 feet(3mts)long, 17mm dia and copper thickness of 250 microns- 1Nos. (II) RDSO approved Earth enhancing compound in 30 kg. Pack - 01 Nos. (III) Copper tape of 25mm x 6mm x 300mm with 99% purity - 02 Nos. and another of 25 mm x 6mmx150mmto terminateonearthelectrode.(iv). Thisinclude supplyof35Sq.mm/16Sq.mm/10Sq.mm multistantsinglecorePVCinsulated coppercable asperIS694forconnectingmainearthelectrode to the equipment. Theearthingmaterialshallbe suppliedasperRDSOspecification RDSO/SPN/197/2008orlatest. Inspection by Consignee. |
41 | Wiringofrelaysinrelayroom/relayhutsetc.as perappdwiringdiagrams.Allwiringmaterial including resistances and condensers etc. except cables/wires to be supplied by contractor (Supply of cables & wires covered separately). It also includes dressing, bunching , lacing and fixing of relay bases. Inspection : Site Engineer |
42 | Supply & Installation of VF transformer (1120/470) as per IRS Spec. No. TC-22-76 or latest) with suitable fixtures and wiring. |
43 | SupplyandinstallationofIPSmoduleofcapacity 24-32VoltDCO/P05AmpSuitableworkon existing IPS of concerned stations. Inspection by RDSO. |