Supply, Transportation , Installation And Commissioning Of Smps Based Integrated Power Supply ( Ips ) System For Pi Up To 4 Line Station In Re-Section With Block Panel & Lc Gate Without Aftc Conforming To Rdso Specn. No. Rdso / Spn / 165 / 2012 ( Ver.3.0 ) Or Latest Along With Remote Indication Panel. This Includes Transportation To Consignee Of Sse / Sig / Gsu / Aii 01 Each At Station Of Aii-Cor-Udz Section Of Aii Division Viz. Aho-Adarsh Nagar, Htd-Hatundi, Ros- Rajosi, Nsd- Nasirabad, Jws- Jhadwasa, Bdw- Bandanwada, Sgw- Singhaval, Makh-Makreda, Bjnr-Bijaynagar, Rpi-Rupaheli, Ssr-Sareri, Rlr-Railaroad, Lma-Lamana, Dwl- Dwuwala, Mdl-Mandal, Bhl-Bhilwara, Mdpa-Mandapia, Hmg-Hamirgarh, Snyn-Soniyana, Ggr-Gangrar, Det- Det, Gsd-Ghosunda, Fan-Fatehnagar, Klh-Khemli, Drb-Debari And Commissioning Is Required Vide Para 3.14 Of Rdso Specification Rdso / Spn / 165 / 2012 Or Latest, Commissioning Of Ips Shall Be Done By The Oem Only. Oem Shall Issue A Certificate Of Fitness Of Installation Before Commissioning. Commissioning Of Integrated Power Supply System After Duly Filling Pre Commissioning Check List Issued By Rdso By Approved Vendor / Oem & Railway Representative Jointly. The Total Number Of Supplies And Their Modules Rating / Capacity Of Each Type Of Supply Shall Be As Per Attached Nwr Drg. This Item Also Includes Supply Of 110V / 300 Ah Lmla Batteries ( 55 Nos ) . It Covers Supply Of Tool Kit Containing All Types Of Tools Required For Maintenance Of Ips And Set Of Spares As Recommended / Mentioned In Rdso Specn. No. Rdso / Spn / 165 / 2012 ( Ver.3.0 ) Or Latest. It Includes Supply Of Proper Hard Wood Stand For Keeping Batteries As Per Sample Approved By Engineer At Site. The Length Of Cables To Be Supplied With Each Ips System Will Be As ( A ) Cable From Ips System To Battery Bank-30 Mtrs. ( 25 Sq. Mm ) ( B ) Cable From Ips System To Asm Box-70 Mtrs ( 12 C X 1.5 Sq. Mm Signalling Cable ) . The Technical Specification Of The Above Said Cables Will Be As Per Rdsos Letter Sts / E / Ips / Genl Dtd. 03.04.08. Installation Is Required. , Supply, Transportation , Installation And Commissioning Of Smps Based Integrated Power Supply ( Ips ) System For Ei Up To 4 Line Station In Re-Section With Block Panel & Lc Gate Without Aftc Conforming To Rdso Specn. No. Rdso / Spn / 165 / 2012 ( Ver.3.0 ) Or Latest Along With Remote Indication Panel. This Includes Transportation To Consignee Of Sse / Sig / Gsu / Aii Each At Pandoli, Kapasan, Bhupalsagar, Bimal And Ranapratapnagar Station Of Aii-Cor-Udz Section And Commissioning Is Required Vide Para 3.14 Of Rdso Specification Rdso / Spn / 165 / 2012 Or Latest, Commissioning Of Ips Shall Be Done By The Oem Only. Oem Shall Issue A Certificate Of Fitness Of Installation Before Commissioning. Commissioning Of Integrated Power Supply System After Duly Filling Pre Commissioning Check List Issued By Rdso By Approved Vendor / Oem & Railway Representative Jointly. The Total Number Of Supplies And Their Modules Rating / Capacity Of Each Type Of Supply Shall Be As Per Attached Nwr Drg. This Item Also Includes Supply Of 110V / 300 Ah Lmla Batteries ( 55 Nos ) . It Covers Supply Of Tool Kit Containing All Types Of Tools Required For Maintenance Of Ips And Set Of Spares As Recommended / Mentioned In Rdso Specn. No. Rdso / Spn / 165 / 2012 ( Ver.3.0 ) Or Latest. It Includes Supply Of Proper Hard Wood Stand For Keeping Batteries As Per Sample Approved By Engineer At Site. The Length Of Cables To Be Supplied With Each Ips System Will Be As ( A ) Cable From Ips System To Battery Bank-30 Mtrs. ( 25 Sq. Mm ) ( B ) Cable From Ips System To Asm Box-70 Mtrs ( 12 C X 1.5 Sq. Mm Signalling Cable ) . The Technical Specification Of The Above Said Cables Will Be As Per Rdsos Letter Sts / E / Ips / Genl Dtd. 03.04.08. Installation Is Required. , Supply Of Smps Based Ips System Suitable For 3 / 4 Line Station In Re Area And Conforming To Rdso Specn. No.Rdso / Spn / 165 / 2012 ( Ver.3.0 ) Or Latest Long With Remote Indication Panel.The Total Number Of Supplies And Their Modules, Rating / Capacity Of Each Type Of Supply Shall Be As Per Attached Drawing Of Nwr. This Item Also Includes Supply Of 110V / 300 Ah Lmla Batteries ( 55 Nos. ) . It Covers Supply Of Tool Kit Containing All Type Of Tools Required For Maintenance Of Ips And Set Of Spare As Recommended / Mentioned In Rdso Specn. No.Rdso / Spn / 165 / 2012 ( Ver.3.0 ) Or Latest. It Includes Supply Of Proper Hard Wood Stand For Keeping Batteries As Per Sample Approved By Engineer At Site.The Length Of Cables To Be Supplied With Each Ips System Will Be As ( A ) Cable From Ips System To Battery Bank - 30 Mtrs. ( 25 Sq Mm ) ( B ) Cable From Ips System To Asm Box - 100 Mtrs. ( 12 C X 1.5 Sq. Mm Signalling Cable ) . The Technical Specification Of The Above Said Cables Will Be As Per Rdsos Letter Sts / E / Ips / Genl Dated 03.04.08. , Supply, Transportation And Commissioning Of Smps Based Integrated Power Supply ( Ips ) System Suitable For Ei Up To 4 Line In Re Section With Block Panel & Lc Gate Without Aftc As Per Rdso Spec No.- Rdso / Spn / 165 / 2012 Ver.-3.0 Or Latest Along With Remote Indication Panel. This Includes Transportation To Consignee Depot & Commissioning Of Ips After Duly Filling Pre Commissioning Checklist By Rdso Approved Vendor & Railway Representative Jointly. The Total Number Of Supplies And Their Modules Rating / Capacity Of Each Type Of Supply Shall Be As Per Attached Nwr Drawing.This Item Also Includes Supply Of 2V / 300Ah Lmla Batteries ( 55 Nos. ) It Covers Supply Of Tool Kit Containing All Type Of Tools Required For Maintenance Of Ips And Set Of Spares As Per Recommended / Mentioned In Rdso Spec. No.- Rdso / Spn / 165 / 2012 Ver.3.0 Or Latest. It Includes Supply Of Proper Hard Wood Stand For Keeping Batteries As Per Sample Approved By Engineer At Site. The Length Of Cables To Be Supplied With Each Ips System Will Be As ( A ) Cable From Ips To Battery Bank-30 Meters ( 25 Sq Mm ) ( B ) Cable From Ips System To Asm Box- 70 Meters ( 12Corex1.5 Sq Mm Signalling Cable ) .Transportation: This Includes Transportation To Consignee Depot. Commissioning : Required Vide Para 3.14 Of Rdso Specification Rdso / Spn / 165 / 2012 Ver.3.0, Commissioning Of Ips Shall Be Done By The Oem Only. Oem Shall Issue A Certificate Of Fitness Of Installation Before Commissioning. Commissioning Of Integrated Power Supply System After Duly Filling Pre Commissioning Check List Issued By Rdso By Approved Vendor / Oem & Railway Representative Jointly. Installation Is Not Required. , Supply, Transportation And Commissioning Of Smps Based Integrated Power Supply ( Ips ) System For Ei Up To 4 Line Station In Re-Section With Block Panel & Lc Gate Without Aftc Conforming To Rdso Specn. No. Rdso / Spn / 165 / 2012 ( Ver.3.0 ) Or Latest Along With Remote Indication Panel. This Includes Transportation To Consignee Depo , Supply Of Smps Based Ips System Suitable For 3 / 4 Line Station In Re Area And Conforming To Rdso Specn. No. Rdso / Spn / 165 / 2012 ( Ver.3.0 ) Or Latest Along With Remote Indication Panel. The Total Number Of Supplies And Their Modules Rating / Capacity Of Each Type Of Supply Shall Be As Per Attached Nwr Drg.This Item Also Includes Supply Of 110V / 300 Ah Lmla Batteries ( 55 Nos. ) It Covers Supply Of Tool Kit Containing All Type Of Tools Required For Maintenance Of Ips And Set Of Spare As Recommended / Mentioned In Rdso Specn. No. Rdso / Spn / 165 / 2012 ( Ver.3.0 ) Or Latest. It Includes Supply Of Proper Hard Wood Stand For Keeping Batteries As Per Sample Approved By Engineer At Site. The Length Of Cables To Be Supplied With Each Ips System Will Be As ( A ) Cable From Ips System To Battery Bank - 25 Mtrs. ( 25 Sq Mm ) ( B ) Cable From Ips System To Asm Box - 35 Mtrs. ( 12 C X 1.5 Sq Mm Signalling Cable ) . The Technical Specification Of These Above Said Cables Will Be As Per Rdsos Letter Sts / E / Ips / Genl Dated 03.04.2008.