Tender For 8113/2023-24/E8 Repair To Joinery, Wall Paneling, False Ceiling, Glazing, Roofing, Flooring And Misc Works At Karu Zone-Ii And Repai/Maint To Sub Main Wiring Including Connected Items Of All Units Of Karu Under Ge 860 Ews, Leh-Jammu And Kashmir

Military Engineer Services-MES has published Tender For 8113/2023-24/E8 Repair To Joinery, Wall Paneling, False Ceiling, Glazing, Roofing, Flooring And Misc Works At Karu Zone-Ii And Repai/Maint To Sub Main Wiring Including Connected Items Of All Units Of Karu Under Ge 860 Ews. Submission Date for this Tender is 22-03-2023. Miscellaneous Finishes Tenders in Leh Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

36410546
Corrigendum : Tender For 8113/2023-24/E8 Repair To Joinery, Wall Paneling, False Ceiling, Glazing, Roofing, Flooring And Misc Works At Karu Zone-Ii And Repai/Maint To Sub Main Wiring Including Connected Items Of All Units Of Karu Under Ge 860 Ews
Open Tender
Indian
Jammu And Kashmir
Leh
22-03-2023

Tender Details

8113 / 2023-24 / E8 Repair To Joinery, Wall Paneling, False Ceiling, Glazing, Roofing, Flooring And Misc Works At Karu Zone-Ii And Repai / Maint To Sub Main Wiring Including Connected Items Of All Units Of Karu Under Ge 860 Ews Repair To Joinery, Wall Paneling, False Ceiling, Glazing, Roofing, Flooring And Misc Works At Karu Zone-Ii And Repai / Maint To Sub Main Wiring Including Connected Items Of All Units Of Karu Under Ge 860 Ews

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Mar-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-03-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 72000.0 /-
Tender Value
INR 36 Lakhs /-

BOQ Items

Name of Work:REPAIR TO JOINERY, WALL PANELING, FALSE CEILING, GLAZING, ROOFING, FLOORING & MISC WORKS AT KARU ZONE-II AND REPAI/MAINT TO SUB MAIN WIRING INCLUDING CONNECTED ITEMS OF ALL UNITS OF KARU UNDERGE 860 EWS
Sl. No. Item Description
1Dismantling of boarding in wall/ceiling, any description, fixed in any position with nails or screws complete all as specified and directed by Engr-in-Charge. (Note: Taking down carefully old FTL fitting recessed mounted light fittings/ceiling complete with all accessories and making necessary electric connection, complete all as specified and directed by Engr-in charge.
2M&L for 4mm thick 3 Nos of ply veneered decorative plywood grade1 (with BWR, resin) with one side of decorative veneered facefixed with screw to timber frame work in ceiling/wall complete all as specified and directed by Engr-in charge.
3M&L for 9mm thick pre-laminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws/nails to timber frame work in wall/ceiling portion complete all as specified and directed by Engr-in charge.
4S&F grid false ceiling GI system powder coated prelude (main runner section 32x24x0.30x3600mm, cross tee 25x24x0.30x1200mm, wall angle 24x24x0.40x3000mm and including providing and fixing PVC pre-laminated in frontside and aluminium foil backed gypsum tile board of size 595 x 595 x 8-9mm fixed in ceiling frame work with necessary fastening GI wire and cleats complete all as specified and directed by Engr-in charge.
5M&L for french polishing on surface of any description width or girth including cleaning and prepairing the surface including a coat of wood filler on new works with two or more coats complete all as specified and directed by Engr-in charge.
6Dismantling of timber scantling in fillets, posts, rafters, purlins etc under 40Sq. Cm in section complete in framed work complete all as specified and directed by Engr-in charge.
7M&L for 2nd class hard wood timber scantling plain fillets square, rectangular in section area exc 13 Sqcm and not exc 25sqcm secured with nails complete all as specified and directed by Engr-in charge.
8M&L for 2nd class soft wood fillets sectional area exc 3 and n exc 6 sqcm rectangular or triangular in section but bullnosed, splayed, chamfered or rounded on one edge of face, secured with nails or brads, complete all as specified and as directed by Engr-in-Charge.
9M&L for preparation of new or previously untreated wooden surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primercomplete all as specified and directed by Engr-in-Charge.
10Taking down of chowkats with shutter (without taking off shutter from frame)n exc 1.5 Sqm each complete all as specified and directed by Engr-in-Charge.
11Taking down of chowkats with shutter (without taking off shutter from frame)exc 1.5 Sqm but n,exc 4.0 Sqm each complete all as specified and directed by Engr-in-Charge.
12Resecuring or easing & adjusting of door shutter of any description without taking downexc 1 Sqm but not exc 2 Sqm , completed all as specified and directed by Engr-in-Charge.
13S&F of 2nd class hard wood, Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed by Engr-in-Charge.
14S&F of 30mm thick, flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, fitted to chowkats complete all as specified and directed by Engr-in-Charge.
15S&F for 30mm thick 2nd class hard wood glazed and skelton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) complete all as specified and directed by Engr-in charge.
16S&F of 100mm size, butt hinges, cold rolled steelwith screw, medium weight , ISI marked complete all as specified and directed by Engr-in-Charge.
17S&F of 75mm size, butt hinges, cold rolled steel with screw, medium weight , ISI marked complete all as specified and directed by Engr-in-Charge.
18S&F of 125mm long Aluminium, anodised, barrel tower bolt, fixed with screws complete all as specified and directed by Engr-in-Charge.
19S&F of 125mm size, extruded aluminium alloy handles fabricated type anodised complete all as specified and directed by Engr-in-Charge.
20S&F of 250mm long, stainless steel, sliding door bolts, plate type, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed by Engr-in-Charge.
21S&F aluminium anodised door shutter aiuminium section weighting 0.55 kg/m including necessary jointing cleats, glazing clips, ruber neoprene packing, handles 02 Nos in each door, hinges anodised aluminium snap beading screw etc. complete all as specifiedmm)
22S&F aluminium anodised window and ventilator shutter, side hung type without sash bars aiuminium section weighting 0.55 kg/m including necessary jointing cleats, glazing clips, ruber neoprene packing, hinges anodised aluminium snap beading screw anodised alumimium fittings such as peg stays 150mm long (1 No), hinges type B-21 100mm long (02 Nos), suitable handle (01 No), complete all as specified and directed by Engr-in-Charge.
23S&F aluminium anodised frame for door, window and ventilator with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engr-in charge.
24M&L for 5.5mm sheet glass ordinary quality white or tinted fixed in aluminium frame in squares exc 0.5 sqm each pane, complete all as specified and directed by Engr-in charge.
25M&L Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed by Engr-in charge.
26S&F in repair Mortice brass lock of 4 lever, vertical type, size 100 mm , complete all as specified and directed by Engr-in charge.
27S&F in repair of aluminum body door closer (extruded section) hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed by Engr-in-Charge.
28S&F in repair of Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, Overall length of cover plate 140mm complete all as specified and directed by Engr-in-Charge.
29Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed by Engr-in-Charge.
30Hacking out old broken glass (any thickness, size, quality or description) from from metal frame including punching or drilling out old glazing pins/spring clips and providing, complete all as specified and directed by Engr-in-Charge.
31S&F of 4mm thick sheet glass, ordinary quality and glazing with oil putty and glazing pins in square n exc 0.5 sq. m in each pane complete all as specified and directed by Engr-in-Charge.
32S&F of 4mm thick figured glass, pin head type and glazing with oil putty and glazing pins in square n exc 0.5 sq. m in each pane complete all as specified and directed by Engr-in-Charge.
33S&F in repair Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with galvanised wire staples, complete all as specified and directed.
34Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing) removing dismantled tile and rubbish off the premises complete all as specified and directed by Engr-in-Charge.
35M&L for Coloured Non Skid Ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in whiteor coloured cement to match over and including screed bed 15mm thick in cement mortor 1:6complete all as specified and directed by Engr-in charge.
36S&F in repair 25mm dia aluminium anodised alloy curtain rod including wooden ornamental/ decorative bracket and end cap complete all as specified and directed by Engr-in charge.
37S&F Galvanised corrugated mild steel sheeting 0.50mm thick with two corrugation side lap, fixed with coach screws and washersas in roofs, walls etc including dismantling complete all as specified and directed by Engr-in charge.
38S&F in repair for SDC Laminated flooring 8mm thick of any coloured, manufactured by Direct Pressure Laminated (DPL) wherein the empty Abrasive aluminium oxide overlay alongwith metamine impregnated decorated film is directly fused with the back with flooring locking profile in designed with double click locking system on the length and single locking width alongwith desire locking strength laid over 1mm thick foam base, complete including removal of existing flooring, complete all as specified and directed by Engr-in charge.
39Taking out old submain wiring from exisiting conduit pipe of any size and description incl joint, complete all as specified and directed by Engr-in-Charge.
40M&L for sub main wiring with 2 run of 2.5 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl one run 2.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate, ISI marked, non metallic PVC conduit 20 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as specified and directed by Engr-in charge. Note : 1. The cost of conduit & accessories is deemed to be included in quoted rates.2. The two run of 2.5 Sqmm wire and one run of 2.50 Sqmm wire will be measured as one unit.
41All as per srl item no. 40 here-in-before but with 2 run of 4.0 sq mm FRLS copper wire with one run 4.0 Sqmm FRLS copper cable as earth wire complete all as specified and directed by Engr-in charge.
42All as per srl item no. 40 here-in-before but with 2 run of 6.0 sq mm FRLS copper wire with one run 6.0 Sqmm FRLS copper cable as earth wire complete all as specified and directed by Engr-in charge.
43All as per srl item no. 40 here-in-before but with 2 run of 10.0 sq mm FRLS copper wire with one run 10.0 Sqmm FRLS copper cable as earth wire complete all as specified and directed by Engr-in charge.
44S&F in replacement of Distribution Board, double Door, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, TPN 04 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof, suitable for incorporation of MCB’s and isolators etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed by Engr-in charge.
45All as per item No 44 here in before but SPN 12 way Distibution Board complete all as specified and directed by Engr-in charge.
46All as per item No 44 here in before but SPN 8 way Distibution Board complete all as specified and directed by Engr-in charge.
47All as per item No 44 here in before but SPN 4 way Distibution Board complete all as specified and directed by Engr-in charge.
48All as per item No 44 here in before but SPN 2 way Distibution Board complete all as specified and directed by Engr-in charge.
49S&F in replacement of MCB, C Curve type, 10 kA, 100 Amp, TPN with over load and short circuit protection, complete all as specified and directed by Engr-in charge.
50S&F in replacement of MCB, C Curve type, 10 kA, 63 Amp, TPN with over load and short circuit protection, complete all as specified and directed by Engr-in charge.
51S&F in replacement of MCB, C Curve type, 10 kA, 20 to 32 Amp, SPN with over load and short circuit protection, complete all as specified and directed by Engr-in charge.
52S&F in replacement of MCB, C Curve type, 10 kA, 40 to 63 Amp, SPN with over load and short circuit protection, complete all as specified and directed by Engr-in charge.
53S&F in replacement of MCB, C Curve type, 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection, complete all as specified and directed by Engr-in charge.
54S&F, in replacement of Blanking plate of plastic, suitable for distribution board complete all as specified and directed by Engr-in charge.
55Earthing complete withgalvanized steel earth plate electrode 600 mmx 600 mm x 6.3 mm thick buried directlyin ground (earth pit notless than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level,connecting to theGalvanised earth lead wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron andsteelearth wire protected by provision of GI lightgrade pipe40 mmbore including provision of concrete pitmade from PCC ( 1:2:4) type B-1 (using20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angleiron40 x 40 x 6 mm and handle of 6 mmdia MS barmade to shape, GI light grade 20 mmbore pipefor watering perforated atbottom, 1.50metre long placed on top edge of earth plate, common salt &charcoalfilling, withfixing arrangement , funnel, wire mesh and earthwork in hard/dense soil, returning filling in and removal of surplus soilto a distance notexceeding50 metres, all as perelectrical plate No 3 of SSR 2009 Part-I and connecting to Panels all as specified or indicated including testing on complete all as specified and as directed by Engineer-in-Charge.
56Supply, installation, testing and commissioning, in replacement,Junction box, cubical type, factory made, outdoor type of Size 45cm(l)x30cm(w)x60cm(h) , dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick,complete with openable shutters in front and rear having proper locking arrangement includingincluding 04 Nos legs made out of angle iron of suitable size and height of each leg shall begrouted in PCC andaluminium busbar of size 400 Amps capacity , Three phase and neutral bus bar , making hot and cold drilling holes to aluminium bus bar . Junction box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a)MCCB 4 pole, 160 Amps,240/415 Volt, 50Hz, 10 KA= 01 Nos (I/C) b) MCB SPN 63 Amps, 240 Volts - 04 Nos (O/G) Note : Unit rate quoted by the contractor here-in-before also includes for fixing and connecting of MCBs and installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
57Taking out old LT under ground cable from trenches / floor / road / wall / pipe / pole of any size and description incl joint, complete all as specified and directed by Engr-in-Charge.
58Supply, laying, testing and commissioning of LT UG cable, XLPE insulated, PVC sheathed, galvanized steel strip armoured electric power cable with stranded aluminium conductor, 1100 volts grade of size 16 sqmm 4.0 core confirming to IS:7098 (Part-I), suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and making connection, complete all as specified and directed by Engr-in-Charge. Note : 1. The cost of Al thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it. 2. Excavation, earth work, sand cushioning and brick protection will be measured and paid separately under respective items.
59All as per srl item no. 58 here-in-before but with 16 Sqmm 2.0 Core complete all as specified and directed by Engr-in-Charge.
60All as per srl item no. 58 here-in-before but with 10 Sqmm 2.0 Core complete all as specified and directed by Engr-in-Charge.
61Taking out old unserviceable/serviceableun-reinforced concrete PCC cable covers from excavated trench all as directed by the Engineer-in-Charge. Note:- Serviceable un-reinforced concrete PCC cablecover kept in safe custody for reuse at site and unserviceable un-reinforced concrete PCC cable cover through in low lying area complete all as specified and directed by Engr-in-Charge.
62Laying only old reinforced PCC cable cover of any size as retrieved from serial item No- 61 above, complete all as specified and directed by Engr-in-Charge.
63M&L for factory made un-reinforced pre cast concrete cable protection cover LV class type - I with size 250mm x 150mm x 40mm laid across the cable (i.e. width of cover along the length of cable) for UG cable protection on the top of the sand cushioning, complete all as specified and directed by Engr-in-Charge.
64Excavation in trenches in hard / dense soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide and getting out including trimming of sides, for laying of cables & foundation of poles, stay assembly, complete all as specified and directed by Engr-in-Charge.
65M & L sand cushioning to underground cable complete all as specified in clause 19.75 of SSR Part - I complete all as specified and directed by Engr-in-Charge.
66Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed by Engr-in-Charge.
67Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified and directed by Engr-in-Charge.
68S&F of GI pipe of 40 mm nominal dia light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wallincluding painting with two coats of aluminium paint over a coat of red oxide paint complete all as specified and directed by Engr-in-Charge. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail