| 1 | Cleaning of running sewage lines 100 mm to 200 mm dia from manhole to manhole by manual / mechanical rodding, removing all sludge / waste and making the line functional including disposing of all sludge / waste etc (in covered tanks) outside M.O.D land complete all as specified and directed. |
| 2 | Cleaning of running sewage lines300 mm dia from manhole to manhole by manual / mechanical rodding, removing all sludge / waste and making the line functional including disposing of all sludge / waste etc (in covered tanks) outside M.O.D land complete all as specified and directed. |
| 3 | Cleaning & desludging manholes depth not exc 1.0 m, of any size & shape by removing all sludge / waste etc from the manholes and finally cleaning with fresh water including disposing of all sludge / waste etc (in covered tanks) outside M.O.D land complete all as specified and directed. |
| 4 | Cleaning & desludging manholes depth exc 1.0 m but not exc 2.0 m, of any size & shape by removing all sludge / waste etc from the manholes and finally cleaning with fresh water including disposing of all sludge / waste etc (in covered tanks) outside M.O.D land complete all as specified and directed. |
| 5 | Cleaning & desludging STP manholes any depth of any size & shape by removing all sludge / waste etc from the manholes and finally cleaning with fresh water including disposing of all sludge / waste etc (in covered tanks) outside M.O.D land complete all as specified and directed. |
| 6 | Cleaning of gully traps / floor traps / nahani traps by removing all sludge / waste etc including cleaning of connected pipe up to 1st Man Hole to remove blockage, and finally washing with clean water including disposing of all sludge / waste etc (in covered tanks) outside M.O.D land complete all as specified and directed. |
| 7 | Removal of blockage from Indian WC / EWC by removing all sludge / waste etc including cleaning of connected pipe up to first manhole to remove blockage, and finally washing with clean water including disposing of all sludge / waste etc (in covered tanks) outside M.O.D land complete all as specified and directed. |
| 8 | Demolition and breaking up drain pipes 150 mm dia (Salt glazed ware, AC or reinforced concrete), set in cement mortar including bedding and haunching complete all as specified and directed. |
| 9 | Demolition and breaking up drain pipes 200 mm dia (Salt glazed ware, AC or reinforced concrete), set in cement mortar including bedding and haunching complete all as specified and directed. |
| 10 | M&L for 150 mm bore reinforced concrete hume pipes, class NP2, laid and jointed with collars complete all as specified and directed. |
| 11 | M&L for 200 mm bore reinforced concrete hume pipes, class NP2, laid and jointed with collars complete all as specified and directed. |
| 12 | M & L for PCC 1:4:8 type D-1 using 20 mm graded stone aggregate as in bedding including haunching & packing under and against the side of pipe 150 mm bore, after they are laid and tested complete all as specified and directed. |
| 13 | M & L for PCC 1:4:8 type D-1 using 20 mm graded stone aggregate as in bedding including haunching & packing under and against the side of pipe 200 mm bore, after they are laid and tested complete all as specified and directed. |
| 14 | Cutting into existing manholes in running sewage line for connecting new drains of 100 / 150 / 200 mm internal dia of pipe, making good to walling and rendering, cutting out branch channel, and as required complete all as specified and directed. |
| 15 | Demolition of reinforced cement concrete including removing the same to a distance of 1.5 km including loading and dumping/ levelling at the destination complete all as specified and directed. |
| 16 | M&L for Pre cast RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in cover slab for manholes/soakage well and similar works supported on walls set in cement mortar 1:6 complete all as specified and directed.Note:- Reinforcement steel will be measured & paid separately. |
| 17 | M & L for mild steel TMT bars 10 mm dia, cut to length, bent to shape required including bending, and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 18 | M&L for cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in coping, benching and like including weathering, slightly round or chamfered angles and throating as directed and including necessary use and waste of formwork complete all as specified and directed. |
| 19 | Demolition of brick work / stone work / PCC block masonry built in Cement mortar complete all as specified and directed. |
| 20 | M&L for Cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete complete all as specified and directed. |
| 21 | M&L for providing precast cement concrete(1:5:8) (using 20mm graded stone aggregate) solid building blocks exc 10 cm in width (with plain or inter locking joints as directed) setting in CM 1:6 complete in wall, pillars and similar works complete all as specified and directed. |
| 22 | Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc,including removal of debries to a distance exc 1.5 km but n. exc 2 km complete all as specified and directed. |
| 23 | M&L for 10 mm thick rendering in cement mortar 1:6 on brick work / concrete surfaces / PCC block / stone masonry wall surface, ifinished the surface even & smooth without using extra cement complete all as specified and directed. |
| 24 | M&L for 15 mm thick rendering in cement mortar 1:4 on brick work / concrete surfaces / PCC block / stone masonry wall surface, ifinished the surface even & smooth without using extra cement complete all as specified and directed. |
| 25 | M & L 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 26 | M & L PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed. |
| 27 | Taking down rainwater/drain pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc, including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories complete all as specified and directed. |
| 28 | S&F PVC (SWR) pipes 75 mm diasingle socketed, in any length, with rubber ring joints jointed with solvent cement, fixed to walls with necessary clamps etc complete all as specified and directed. |
| 29 | S&F PVC (SWR) pipes 75 mm diasingle socketed, in any length, with rubber ring joints jointed with solvent cement, laid in trenches or in floors complete all as specified and directed. |
| 30 | S&F PVC (SWR) pipes 110 mm diasingle socketed, in any length, with rubber ring joints jointed with solvent cement, fixed to walls with necessary clamps etc complete all as specified and directed. |
| 31 | S&F PVC (SWR) pipes 110 mm diasingle socketed, in any length, with rubber ring joints jointed with solvent cement, laid in trenches or in floors complete all as specified and directed. |
| 32 | S&F PVC (SWR) bends 110 mm dia complete all as specified and directed. |
| 33 | S&F PVC (SWR) bends 75 mm dia complete all as specified and directed. |
| 34 | S&F PVC (SWR) vent cowl 110 mm dia complete all as specified and directed. |
| 35 | S&F PVC (SWR) vent cowl 75 mm dia complete all as specified and directed. |
| 36 | S&F in repair 75 mm dia cast iron sand cast pipe, for soil, waste and vent in any length with or without ears, laid in trenches or in floors, with cement joints, complete all as specified and directed . |
| 37 | S&F in repair 75 mm dia cast iron sand cast pipe, for soil, waste and vent in any length with or without ears, fixed on wall with MS clamp, with cement joints, complete all as specified and directed. |
| 38 | S&F in repair 100 mm dia cast iron sand cast pipe, for soil, waste and vent in any length with or without ears, laid in trenches or in floors, with cement joints, complete all as specified and directed. |
| 39 | S&F in repair 100 mm dia cast iron sand cast pipe, for soil, waste and vent in any length with or without ears, fixed on wall with MS clamp, with cement joints, complete all as specified and directed. |
| 40 | S&F in repair 75 mm bore cast iron oval access door bend (any radius) diminishing pieces or tapers (Larger bore measured) complete all as specified and directed. |
| 41 | S&F in repair 100 mm bore cast iron oval access door bend (any radius) diminishing pieces or tapers (Larger bore measured) complete all as specified and directed. |
| 42 | S&F in repair 75 mm bore cast iron branch piece single, equal or unequal, ordinary or inverted (Spigot or socketed type) or parallel branches with oval access door complete all as specified and directed. |
| 43 | S&F in repair 100 mm bore cast iron branch piece single, equal or unequal, ordinary or inverted (Spigot or socketed type) or parallel branches with oval access door complete all as specified and directed. |
| 44 | S&F in repair 100 mm bore cast iron socket (double) collar connected to branch piece, bend or parallel branches complete all as specified and directed. |
| 45 | S&F in repairs stainless steel grating of size 150 mm x 150 mm fixed with cement screed 1:4 complete all as specified and directed. |
| 46 | S&F in repair 450 mm long PVC connections 15 mm size with PTMT nuts at both ends complete all as specified and directed. |
| 47 | Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc, n exc 10 Sqm on plan area and getting out in soft / loose soil complete all as specified and directed. |
| 48 | Returning, filling inincluding spreading, leveling, watering and well ramming in layers not exc 25 cm thick using excavated soil complete all as specified and directed. |
| 49 | Removing excavated soil to a distance exc 250 mtr but not exc 500 mtr and depositing where directed at a level of n.exc 1.5 m above the starting point all complete all as specified and directed. |
| 50 | Demolition of concrete surfaces in ground floor and paving n.exc. 15cm thickness (below or above ground level) and removing the same to a distance of 1.5 KM including loading and dumping/ levelling at the destination complete all as specified and directed. |
| 51 | M&L 100 mm thick plain cement concrete 1:2:4 type B2 (using 40 mm graded stone aggregate) in hard standing/path in aincluding spike rolling to surface and making impression of expanded metal whilst the concrete is green complete all as specified and directed. |
| 52 | M&L for 75 mm thick plain cement concrete 1:3:6 type C1 (using 20 mm graded stone aggregate) as in plinth protection, including finishing the surface even and fair complete all as specified and directed. |
| 53 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish of the premises complete all as specified and directed. |
| 54 | M & L for 25 mm thick cement concrete type B0 1:2:4(using 12.5 mm graded stone aggregate) as in flooring complete all as specified and directed. |
| 55 | M & L for Non - skid coloured Ceramic tiles (1st quality) not less than 7 mm thick of size exc 0.06 sqm but n exc 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles over & including 15mm screed bed or bedding in CM 1:6 complete all as specified and directed. |
| 56 | M&L coloured Non skid ceramic joint free floor tiles 7 to 8 mm thick (Square/rectanguler) area of each tile exceeding 0.11 sqm but not exeeding 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cementto match the tiles over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 57 | M&L for Glazed ceramic tiles in vertical surface 350x250x7mm / 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match slurry and pointed in white or coloured cement to match over and including 10 mm thick backing coat of mortar in CM 1:4 for laying wall tiles finishes complete all as specified and directed. |
| 58 | Dismantling of stone slabs and granite laid dry or laid dry and pointed of any description or thickness in floors, complete all as specified and directed. |
| 59 | M&L for 100 mm thick cement concrete (1:4:8) type D2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed. |
| 60 | Material & Labour for machine pressed precast concrete interlocking paver block of approved shape and size of 60 mm thickness, with minimum compressive strength of 35 N / Sqmm (M-35 grade), without correction factor for chamfering, made in rubber moulds with 0.50 mm thick scratch proof lacquer coating, and top surface with white cement and pigmentcomplete all as specified and directed. |
| 61 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 62 | S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 63 | Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing (Beam, tee, angle, channel or flat section) including distance pieces, cleats etc complete all as specified and directed. |
| 64 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 65 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 66 | Excavating soft / loose soil in post holes (or similar holes) each n.exc. 0.5cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm complete all as specified and directed. |
| 67 | M&L for cement concrete in CM 1:2:4 type B2 (using 40mm graded stone aggregate) in foundation complete all as specified and directed. |
| 68 | Removing excavated material n.exc. 50m and deposting where directed at a level n.exc. 1.5m above the starting point complete all as specified and directed. |
| 69 | Supply and fix in repair white vitreous china squatting pan ‘ORISSA’ pattern of size 580mm x 440 mm white with integral foot rests with ‘P’ or ‘S’ trap of Cast iron 100 mm , front or back inlet including all connection and provision of lime concrete base complete all as specified and directed.. |
| 70 | S&F in repairs white Vitreous china wash down water closet (pedestal pattern) with fixing bolt, plastic water closet seat cover with hinges, white, closed pattern with flat bottom, and cover with aluminised hinging device, \"P\" or \"S\" trap of 100 mm bore including all connection complete all as specified and directed. |
| 71 | S&F in repair 10 Ltr capacity PVC valveless, syphonic action type, flushing cistern low level, white, with inlet ball valve, float and handle including brackets, flushing pipe, 450 mm long PVC Connection complete all as specified and directed. |