}

Tender For Smoke, Fire Detection, Alarm System., agra-Uttar Pradesh

North Central Railway has published Tender For Smoke, Fire Detection, Alarm System.. Submission Date for this Tender is 08-11-2022. Railway Ancillaries Tenders in agra Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

34151364
Tender For Smoke, Fire Detection, Alarm System.
Open Tender
NCB
Uttar Pradesh
Agra
08-11-2022

Tender Details

Supply Of Smoke, Fire Detection, Alarm System.Smoke, Fire Detection, Alarm System., Supply, Installation, Testing & Commissioning Of Networkable Type Micro Processor Based Addressable Fire Alarm Control Panel ( Facp ) Complying To Rdso Spec Rdso / Spn / 217 / 2021 Ver 3 Or Latest. The Number Of Detector And Devices Per Loop Should Be Up To 159. The Facp Shall Include A Backlit Liquid Crystal Display Individual Color Coded System Status Leds, 2 Nos Sounder Circuit For Audiovisual Devices And Alphanumeric Keypad For The Field Programming And Control Of The Fire Alarm System. The Facp Shall Have Provision For Gsm Based Dialer To Send Automated Sms To At Least 5 Pre Selected Moble Numbers. The Facp Shall Also Have Provision To Network On Lan & Communicate To The Graphical Application On Tcp / Ip. The Facp Shall Have Built In Power Supply, Battery Charger And Battery Backup For 24 Hours Normal Operation. The Panel Shall Be Ul / Lpcb / Vds Approved And Comply To Nfpa-72 / En54 Requirement. , Supply, Installation, Testing & Commissioning Of Analogue Addressable Multi Sensor Detector With Inbuilt Isolator / Isolator Base Having Photo, Fixed Heat And Ror Heat Detection Feature And 360 Degree View Led And Minimum 5 Level Of Sensitivity Setting Complying To Rdso / Spn / 217 / 2021 Ver 3 Or Latest. Operating Temperature -10 To 60 Degree Celsius, Humidity Uo To 85%, As Per Latest Ul / Lphb / Vds Approved / Listed , Supply, Installation, Testing & Commissioning Of Analogue Addressable Type Break Glass Manual Call Point ( Red Colour ) With Inbuilt Fault Isolator Or Alternate Arrangement Which Shall Isolate The Mcp In Case Of Short Circuit. The Mcp Should Have Visual Indication For Its Operation. Approval - Ul / Lpcb / Vds Listed And Shall Comply To Rdso / Spn / 217 / 2021 Ver 3 Or Latest. , Supply, Installation, Testing & Commissioning Of Electronic Hooter ( Red Colour ) With Min 85 Db Output Approval - Ul-Lpcb / Vds Listed And Shall Comply To Rdso / Spn / 217 / 2021 Ver 3 Or Latest. , Supply, Installation, Testing & Commissioning Of 2X1.5 Sqmm Atc Fire Survival Flexible / Armoured Cable With Backbox, Glands & Other Accessories. Armoured & Unarmoured ( Ci ) Cables Should Meet Fire Performance Test Under Simultaneous Action And Flame, Water Stress And Impacts On Single Sample At 950 Degree Celsius For Minimum 2 Hours, Certified By Ul Or Fm Or Vds Or Lpcb Or Bre Global Or Any Recognized Lab By Government Of India. Complying To Rdso / Spn / 217 / 2021 Ver 3 Or Latest. ( 01 Set= Min 280 Mtrs. Any Additional Requirement As Per Site Condition Shall Be Supplied By Contractor At No Additional Cost. ) , Supply, Installation, Testing & Commissioning Of Resettable Analog Type Linear Heat Sensing ( Lhs ) Cable As Per Rdso Specification No. Rdso / Spn / 217 / 2021 Ver 3 Or Latest , Supply, Installation, Testing & Commissioning Of Lhs Interface Module With All Accessories As Per Rdso Specification No. Rdso / Spn / 217 / 2021 Ver 3.0 Or Latest And Ul / Fm / Vds / Lpcb Certified / Approved. , Supply, Installation, Testing & Commissioning Of Networkable Type Micro Processor Based Addressable Fire Alarm Control Panel ( Facp ) Complying To Rdso Spec Rdso / Spn / 217 / 2021 Ver 3 Or Latest. The Number Of Detector And Devices Per Loop Should Be Up To 159. The Facp Shall Include A Backlit Liquid Crystal Display Individual Color Coded System Status Leds, 2 Nos Sounder Circuit For Audiovisual Devices And Alphanumeric Keypad For The Field Programming And Control Of The Fire Alarm System. The Facp Shall Have Provision For Gsm Based Dialer To Send Automated Sms To At Least 5 Pre Selected Moble Numbers. The Facp Shall Also Have Provision To Network On Lan & Communicate To The Graphical Application On Tcp / Ip. The Facp Shall Have Built In Power Supply, Battery Charger And Battery Backup For 24 Hours Normal Operation. The Panel Shall Be Ul / Lpcb / Vds Approved And Comply To Nfpa-72 / En54 Requirement. , Supply, Installation, Testing & Commissioning Of Analogue Addressable Multi Sensor Detector With Inbuilt Isolator / Isolator Base Having Photo, Fixed Heat And Ror Heat Detection Feature And 360 Degree View Led And Minimum 5 Level Of Sensitivity Setting Complying To Rdso / Spn / 217 / 2021 Ver 3 Or Latest. Operating Temperature -10 To 60 Degree Celsius, Humidity Uo To 85%, As Per Latest Ul / Lphb / Vds Approved / Listed. , Supply, Installation, Testing & Commissioning Of Analogue Addressable Type Break Glass Manual Call Point ( Red Colour ) With Inbuilt Fault Isolator Or Alternate Arrangement Which Shall Isolate The Mcp In Case Of Short Circuit. The Mcp Should Have Visual Indication For Its Operation. Approval - Ul / Lpcb / Vds Listed And Shall Comply To Rdso / Spn / 217 / 2021 Ver 3 Or Latest. , Supply, Installation, Testing & Commissioning Of Electronic Hooter ( Red Colour ) With Min 85 Db Output Approval - Ul-Lpcb / Vds Listed And Shall Comply To Rdso / Spn / 217 / 2021 Ver 3 Or Latest. , Supply, Installation, Testing & Commissioning Of Electronic Strobe Approval - Ul / Lpcb / Vds Listed And Shall Comply To Rdso / Spn / 217 / 2021 Ver 3 Or Latest. , Supply, Installation, Testing & Commissioning Of 2X1.5 Sqmm Atc Fire Survival Flexible / Armoured Cable With Backbox, Glands & Other Accessories. Armoured & Unarmoured ( Ci ) Cables Should Meet Fire Performance Test Under Simultaneous Action And Flame, Water Stress And Impacts On Single Sample At 950 Degree Celsius For Minimum 2 Hours, Certified By Ul Or Fm Or Vds Or Lpcb Or Bre Global Or Any Recognized Lab By Government Of India. Complying To Rdso / Spn / 217 / 2021 Ver 3 Or Latest. ( 01 Set= Min 280 Mtrs. Any Additional Requirement As Per Site Condition Shall Be Supplied By Contractor At No Additional Cost. ) , Supply, Installation, Testing & Commissioning Of Resettable Analog Type Linear Heat Sensing ( Lhs ) Cable As Per Rdso Specification No. Rdso / Spn / 217 / 2021 Ver 3 Or Latest , Supply, Installation, Testing & Commissioning Of Lhs Interface Module With All Accessories As Per Rdso Specification No. Rdso / Spn / 217 / 2021 Ver 3.0 Or Latest And Ul / Fm / Vds / Lpcb Certified / Approved.

Key Value

Document Fees
Refer document
EMD
INR 711240.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail