Repair And Maintenance Of Old Unserviceable Lt Xlpe Cable , 11 Kv Ht Xlpe Underground Cable, Lt Steel Tubular Poles, Pole Box Assembly And Connected Items At 4 No Pf, Station Road, Maude Road, Mall Road, Polo Road, Church Road, Cassel Ro, New Delhi-Delhi

Military Engineer Services-MES has published Repair And Maintenance Of Old Unserviceable Lt Xlpe Cable , 11 Kv Ht Xlpe Underground Cable, Lt Steel Tubular Poles, Pole Box Assembly And Connected Items At 4 No Pf, Station Road, Maude Road, Mall Road, Polo Road, Church Road, Cassel Ro. Submission Date for this Tender is 30-08-2022. Railway Ancillaries Tenders in New Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

32805071
Corrigendum : Repair And Maintenance Of Old Unserviceable Lt Xlpe Cable , 11 Kv Ht Xlpe Underground Cable, Lt Steel Tubular Poles, Pole Box Assembly And Connected Items At 4 No Pf, Station Road, Maude Road, Mall Road, Polo Road, Church Road, Cassel Ro
Open Tender
Indian
Delhi
New Delhi
30-08-2022

Tender Details

Repair And Maintenance Of Old Unserviceable Lt Xlpe Cable , 11 Kv Ht Xlpe Underground Cable, Lt Steel Tubular Poles, Pole Box Assembly And Connected Items At 4 No Pf, Station Road, Maude Road, Mall Road, Polo Road, Church Road, Cassel Road, Tig

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-Jul-2022 REVISED BOQ BOQ 16-07-2022
2 04-Jul-2022 REVISED DATE Date 16-08-2022
3 16-Aug-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-08-2022
4 23-Aug-2022 DATE EXT Date 30-08-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 100000.0 /-
Tender Value
INR 49.78 Lakhs /-

BOQ Items

Name of Work : REPAIR AND MAINTENANCEOF OLD UNSERVICEABLELT XLPECABLE , 11 KV HT XLPE UNDERGROUNDCABLE, LT STEEL TUBULAR POLES, POLE BOX ASSEMBLYAND CONNECTED ITEMS AT4 NO P/F, STATION ROAD, MAUDE ROAD, MALL ROAD, POLO ROAD, CHURCH ROAD, CASSEL ROAD, TIGRIS ROAD, MANDIR MARG, HARBAKSH STADIUM, MANEKSHAW OFFICERS ENCLAVE, URBAN VILLAGE, PARADE ROAD, PARADE CAMP, DGNCC AREA, MANEKSHAW CENTREAND ADJOINING AREA OF AGE (U) ELECT SUPPLY NO II UNDER GE (U) ELECT SUPPLY DELHI CANTT-10.
Sl. No. Item Description
1Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in softloose soil for laying / taking up/ taking down of cablesand getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
2Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
3Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
4Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified.
5S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
6All as per srl item No 5 here-in-before but using old bricks obtained under srl item No1 here in before.
7Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm for cable protection
8All as per srl item No 5 here-in-before but using old cable coverobtained under srl item No1 here in before.
9Supply,layingjointing , testing and connecting in replacement of LTXLPE PVC insulated, screened, PVCbedded, galvanised steel strip or wire armoured,electric power cable (heavy duty) with multistranded aluminum conductors,IS 7098marked, suitable for LT 1100 Voltsystem, laid in trenchesfixed to pole, including jointing & testing complete all as specified and directed of following sizes:- Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule.
1016 Sqmm 4 core
1125 Sqmm 4 core
1235 Sq mm 3.5 core
1350 Sq mm 3.5 core.
1470 Sqmm 3.5 core
1595 Sqmm 3.5 core
16120 Sqmm 3.5 core
17185 Sqmm 3.5 core
18240 Sqmm 3.5 core
19300 Sqmm 3.5 core
20630 Sqmm single core
21Supplying, laying, jointing testing and connecting in replacementXLPE insulated, screened, PVCbedded, galvanised steel strip or wire armoured,electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed of following sizes
2295 sqmm 3 core.
23120 sqmm 3 core.
24185 sqmm 3 core
25240 sqmm 3 core
26300 sqmm 3 core
27Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 160 mm dia suitable for 0.6 mpa working pressure complete all as directed by Engr-in-charge.
28Boring of hole under road/pavement/hard standing or any other situation by manual means and suitable for passing of GI pipe 100 to 150 mm bore and making good both ends all specified and directed
29S&F in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah of following bore sizes
30150mm
31100 mm .
3280 mm
3350 mm
34Taking outfaulty underground1100 Volt LT cable of differentsizes by excavation and removingbricksof any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using newbricks as required. Note: (a) 1100Volt LTcable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable brickswill be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
35Taking outfaulty underground11000 VoltHTcable of differentsizes by excavation and removingPCC cover of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using newbricks as required. Note: (a) 11000Volt HTcable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable PCC cable coverwill be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
36Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as directed for the following sizes :-
3716-50 Sqmm x 3.5 core/ 4 core
3870-150 Sqmm x 3.5 core
39185 -240 Sqmm x 3.5 core
40Supply andfix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable offollowing size :-
4195 Sqmm 3 core.
42120 Sqmm to 185 Sqmm, 3 core.
43240 Sqmm to 300 Sqmm 3 core
44Supply andfixCable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable offollowing size :-
4595 Sqmm 3 core.
46120 Sqmm to 185 Sqmm, 3 core.
47240 Sqmm to 300 Sqmm 3 core
48Supply andfix Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size :-
4995 Sqmm 3 core.
50120 Sqmm to 185 Sqmm, 3 core.
51240 Sqmm to 300 Sqmm 3 core
52Supplying, laying, jointing testing and connecting in replacementHT cable, 11000 volts (E) grade, with Aluminum conductor ofsize 1000 Sqmm,single core, XLPE insulated, PVC sheathed, screened, Armoured with GI strip(Earthed), screened by a layer of extruded semi conducting cross linkable compound, copper tape, cross laid up with prefiller complete all as specified and directed.
53Supply andfixCable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 1 core XLPE armoured aluminium conductor cable 1000 Sqmm
54Supply andfixCable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 1 core XLPE armoured aluminium conductor cable 1000 Sqmm
55Taking down unservicable RCC/ steel tubular poles of any type and supply & installingsteel tubular swaged poles type 410 SP-31 (9 mtr long) of approx wt.147 kg conforming to IS 2713 (Part-II)including excavation, earth work, PCC foundation, base plate,PCC coping,GI pipe for cable protection etc. and GI bracket for fitting mounting, complete all as per manufacturer"s instructions and as specified and as directed by E-in-charge. NOTE:- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole and GI bracket made of GI pipe medium grade 40 mm bore, 1.5 mtr long for fixing of street light fitings . The steel pole shall be painted by bituminious paint total length inside and up to planting depth outside and remaining portion of pole painted with two coat of aluminium paint over a coat of red oxide complete all as specified and directed.
56Earthing in replacement complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.10 m below normal ground level) with top edge of earth plate not less than 1.5mbelow normal ground level, connected to galvanized iron strip 32mm x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electricalplate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b)The quoted rates shall also deemed to include the cost of earth test point and earth strip/GIlead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
57S&F in replacement KIOSK box wheather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminium bus bar 4 strips for 3 phase and neutral 63 Ampsincluding embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and directed.Incluiding MS clamp of size 25x3 mm with suitable size nut,bolts & washer.
58M&L for re-painting of LT Panels/feeder pillarsof approx size 2 to 4 Sqmwith 2 coats of super enamal paint over a coat of red-oxide with sparygun including writing of feeder pillar numbers in appropriate size of letters as directed.
59All as per item No 26 here in beforebut of approx size upto 1.90 Sqm
60M&L for re-painting of LT Steel tubular poles of any sizes with apply of 2 coats of aluminium paint including rubbing with wire brush/emery paper & writing pole Nos in appropriate size of letters including making yellow and black strips upto height of 1.5 mtr above from ground level complete all as specified and directed.
61Supplying and fixing in replacement ofLED street light fitting fitting 70 Watt complete all as specified and directed.
62Supplying and fixing in replacement LED street light fitting fitting 45Watt complete all as specified and directed.
63Taking down unservicable RCC/ steel tubular poles of any type and supply & installingsteel tubular swan neck pole type 410 SP-31 (9 mtr long) complete with mild steel base plate, finial taper plug, bolts, nuts and screws including two coats of aluminium painting over a coat of primer for exposed surfaces and two coats of bituminous black paint over a coat of primer to the surfaces in contact with concrete inclusing two runs of PVC insulated 1100V multi-stranded copper wire of size 2.5 Sqmm from the junction box to the fitting complete all as specified and directed. Note :- The unit rate in this item is deemed to be included the cost oif exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole and GI bracket made of GI pipe medium grade 40 mm bore, 1.5 mtr long for fixing of street light fitings . The steel pole shall be painted by bituminious paint total lenth inside and up to planting depth outside
64Supply and fix in replacement air break switch gang operated tripple pole mechanically operated mechanism, switch air break gang operated mounted on 15 Nos insulator and steel frame with operating rod of 25 mm bore GI Pipe and locking arrangements worked from ground level for current rating 400 Amps, HT 11 KV grade including drop out fuses and necessary silver coper coating jumpers and making all electrical connections complete.
65M&L in replacement ofearthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 3.5 m below normal ground level) with top edge of earth plate not less than 2.5mbelow normal ground level, connected to galvanized iron strip 32X4 mm by means of electric arc welding of galvanised iron or steel as shown in electricalplate No 3 of SSR Part I, connected to earth test point and the equipment on the other side complete all as specified, including testing and commissioning complete all as directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe light grade etc. (b)The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI earthing and protection pipe upto 7.5 meter beyond the earth plates electrode.
66M & L for 2 coat ofaluminiumpainting over a coat of red oxide to steel surfacesof HT 4/6 pole sturcture (Angle Iron/MS channel /MS clamp etc)including preparation of oldsurface complete all as specified.
67Material & Labour for replacement of jumper/bus bar made ofACSR conductorof existing sizeon HTFour/Sixpole structurehaving 2/3 incoming/outoing feeder including bus bar with PVC sleeve , lugs , nut bolts and washerscomplete all as directed.
68All as per Serial item No 35here-in-before but 4/6 incoming/outoing feeder complete all as specified and as directed
69M & L for cutting and removing grass, vegetation bushes etc from surrounding4 pole/6 pole HT structure , outside area of HT installation and removing all rubbish to a distance not exceeding 50 m as directed.
70Material and labour for sprading of stone aggregate of nominal size not more than 25mm under 4/6 pole HT structure /surounding area of outdoor RMUmanually without damaging any equipments, cable or parts , spreading & levelling of finished gravel uniformaly in layers n. ecc. 15 cm thick watered and rammed to true surface all as specified and directed
71Suplying and laying in replacement in sub station 3.3 to 11 KV electrical insulation mat ISI markedcomplete all as directed by Engr-in-charge
72Supplying and fixing in replacementmale contact/moving contact for gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.
73Supplying and fixing in replacement female contact /fix contact jawfor gang operated air break device 11 KVcomplete all as directed at site by Engr-in-charge.
74Supplying and fixing in replacementtinned copper flexible jumper 200 Amp/400 Amp for gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.
75Supplying and fixing in replacement MS jumper carrierfor gang operated air break device 11 KVcomplete all as directed at site by Engr-in-charge.
76Supplying and fixing in replacement back connector plate for gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.
77Supplying and fixing in replacement porcelain post insulator for gang operated air break device 11 KVcomplete all as directed at site by Engr-in-charge.
78Supply installation & commissioning in replacement of 24V, 40A Float Cum Boost Battery Charger unit includingbattery bank comprising 02 Nos of 12 Volts, 00 AH sealed maintenance free batteries.The CCCV battery charger consisting ofcopper wound,air cooled transformer, 01 Set single phase full wave bridge rectifier consisting ofdiodes andSCRs, liberally rated mounted on heat sink andcomplete with resistor/condenser network for surge supperssion .During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller , DCdigital ammeter,DC digitalvoltmeter, Potentiometer , DC, MCB for reverse battery protection . The charger should have alarm annunciation with visual and audible alarm with manual reset facility forfuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness , louvers for ventilation , gland plate will be provided for cable entry from bottom .The battery charger shall be divided into two compartments.The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries. Tech specification shall be as under:- (a) Input working voltage-180 -270 Volts (b) Nominal Input Voltage - 230 V , AC , 50 Hz,1 (c) On load input power factor- > 0.8 (d) On load unit watt efficiencies-> 80% (e) No load losses of complete charge-< 10% (f)Ripple contents on the load (RMS)= 1% to 5% (g) Over load - 110% for 30 minutes and will give visual indication for over load condition. (h) Boost charging - 2.4 V/Cell . (j)Float charging -2.15 V/Cell (k)Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode. (l)Reverse polarity -No damage will caused .A visual indication for reverse polarity will appear with an audio alarm. (m)Short circuit-MCB protecton provided.
79S&F in replacement pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers,nut size 150 mm height 150mm dia, 11000 volts grade complete all as specified and directed.
80S&F in replacement Lightening arrestors expulsion type with all fittings, transmission class, discharge capacity 10 kilo Amps suitable for 11000 volts complete as specified and directed.
81Dismantling and removing of PCC 4 Pole/6 Polestructurest from sites andmaking good to the existing surfaces complete all as specifed and directedby Engr-in-Charge
82Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work orderand shall be verified by the Eng-in-charge
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail