Supply, Erection And Commissioning Of 2 Nos. V.T. Pumps Having Discharge 10 Cs Each And 1 Nos. V.T. Pumps Having Discharge 5 Cs Along-With Allied Accessories For Permanent Pump House At 1000 R Of Uplana Minor For Villages Uplana, Uplani And Dera Varn Su, karnal-Haryana

Irrigation Department has published Supply, Erection And Commissioning Of 2 Nos. V.T. Pumps Having Discharge 10 Cs Each And 1 Nos. V.T. Pumps Having Discharge 5 Cs Along-With Allied Accessories For Permanent Pump House At 1000 R Of Uplana Minor For Villages Uplana, Uplani And Dera Varn Su. Submission Date for this Tender is 01-07-2022. Anti Corrosives Tenders in karnal Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

32736026
Supply, Erection And Commissioning Of 2 Nos. V.T. Pumps Having Discharge 10 Cs Each And 1 Nos. V.T. Pumps Having Discharge 5 Cs Along-With Allied Accessories For Permanent Pump House At 1000 R Of Uplana Minor For Villages Uplana, Uplani And Dera Varn Su
Open Tender
Indian
Haryana
karnal
01-07-2022

Tender Details

Supply, Erection And Commissioning Of 2 Nos. V.T. Pumps Having Discharge 10 Cs Each And 1 Nos. V.T. Pumps Having Discharge 5 Cs Along-With Allied Accessories For Permanent Pump House At 1000 R Of Uplana Minor For Villages Uplana, Uplani And Dera Varn Supply, Erection And Commissioning Of 2 Nos. V.T. Pumps Having Discharge 10 Cs Each And 1 Nos. V.T. Pumps Having Discharge 5 Cs Along-With Allied Accessories For Permanent Pump House At 1000 R Of Uplana Minor For Villages Uplana, Uplani And Dera Varn , Supply, Erection And Commissioning Of Axial Flow Water Lubricated V.T. Pumps Of 10 Cs. Capacity With Lift Upto 15’, With Y-Body Along With Bend And Operating At Speed Of 1440 Rpm Complete In All Respect With Bends, Nipple Including Jointing With Rubber Sheets, Fabrications, Transportation Etc. At Site As Per Technical Specifications Approved By I&Wr Department, Haryana And Satisfaction Of Site Engineer. , Supply Of 50 Hp Motor, 415 Volt ( + / -10% ) , 50 Hz ( + / -3% ) , 1440 Rpm, 4 Pole Ie2, Tefc, Continuous Duty Vertical Flange Mounted Solid Shaft Squirrel Cage, Induction Motor As Per Technical Specifications Approved By I&Wr Department, Haryana And Satisfaction Of Site Engineer. , Providing And Commissioning Of 50 Hp Fully Automatic Star Delta Starter With 160 Amp Mccb, Contactors 70A / 70A / 70A, Microcontroller Based Protection Relay, Ct’S With All Allied Accessories With Compatible Cable Upto Motor For Vt Pump Of 10 Cs. Capacity As Per Technical Specifications Approved By I&Wr Department, Haryana And Satisfaction Of Site Engineer. , Supply Of Ms Delivery Pipe Having 7.1 Mm Thickness, 14’’ Diameter Along With Required M.S. Flanges In Accordance With Is 2062:1989 Grade-A With Two Coat Of Anti Corrosive Bituminous Based Paint As Per The Satisfaction Of Site Engineer. , Supply, Erection And Commissioning Of Axial Flow Water Lubricated V.T. Pumps Having Discharge Of 05 Cs Capacity With Lift Upto 15’, With Y-Body Along With Bend And Operating At Speed Of 1440 Rpm Complete In All Respect With Bends, Nipple Including Jointing With Rubber Sheets, Fabrications, Transportation Etc. At Site As Per Technical Specifications Approved By I&Wr Department, Haryana And Satisfaction Of Site Engineer. , Supply Of 30 Hp Motor, 415 Volt ( + / -10% ) , 50 Hz ( + / -3% ) , 1440 Rpm, 4 Pole Ie2, Tefc, Continuous Duty Vertical Flange Mounted Solid Shaft Squirrel Cage, Induction Motor As Per Technical Specifications Approved By I&Wr Department, Haryana And Satisfaction Of Site Engineer. , Providing And Commissioning Of 30 Hp Fully Automatic Star Delta Starter With Mccb 100 A, 3 Pole 25 Ka, Contactors, 40A, 40A, 40Amicrocontroller Based Protection Relay, Ct’S With All Allied Accessories With Compatible Cable Upto Motor For Vt Pump Of 05 Cs Capacity As Per Technical Specifications Approved By I&Wr Department, Haryana And Satisfaction Of Site Engineer. , Supply Of Ms Delivery Pipe Having 7.1 Mm Thickness, 12’’ Diameter Along With Required M.S. Flanges In Accordance With Is 2062:1989 Grade-A With Two Coat Of Anti Corrosive Bituminous Based Paint As Per The Satisfaction Of Site Engineer. , Supply And Fixing Of Structural Steel Beams Ismb 300 For Mounting / Installation Of V.T. Pumps In Pump House Chamber As Per As Per The Satisfaction Of Site Engineer. , S / E / C Of Lt Distribution Panel Having Incomer Mccb Of 300Amps, 4 Pole, 35 Ka And 2 Nos. Outgoings Of 160 Amps, 3 Pole 25 Ka, 1 No. Mccb Of 100A, 3 Pole 25 Ka Along With One No. Mccb Of 63A, 4 Pole For Lighting Loads. Auto / Manual Capacitor Bank Of 50 Kvar In 4 Steps Having Incomer Mccb Of 160 A, Each Stage Of Capacitor Bank Should Have Separate Mccb As Per Specification Of Hid , 6214-Znr Steel Cage Fag / Skf / Koyo

Key Value

Document Fees
INR 2500 /-
EMD
INR 96000.0 /-
Tender Value
INR 47.87 Lakhs /-

BOQ Items

Name of Work: Supply, erection and commissioning of 2 Nos. V.T. Pumps having discharge 10 Cs each and 1 Nos. V.T. Pumps having discharge 5 Cs along-with allied accessories for Permanent Pump house at 10000/R of Uplana Minor for villages Uplana, Uplani and Dera Varna
Sl. No. Item Description
1Supply, erection and commissioning of Axial Flow water lubricated V.T. Pumps of 10 cs. Capacity with lift upto 15’, with Y-Body along with bend and operating at speed of 1440 RPM complete in all respect with bends, nipple including jointing with rubber sheets, fabrications, transportation etc. at site as per technical specifications approved by I&WR Department, Haryana and satisfaction of site Engineer.
2Supply of 50 HP motor, 415 volt(+/-10%), 50 Hz (+/-3%), 1440 RPM, 4 Pole IE2, TEFC, continuous duty vertical flange mounted solid shaft squirrel cage, induction motor as per technical specifications approved by I&WR Department, Haryana and satisfaction of site Engineer.
3Providing and commissioning of 50 HP fully automatic star delta starter with 160 Amp MCCB, Contactors 70A/70A/70A, microcontroller based protection relay, CT’s with all allied accessories with compatible cable upto motor for VT pump of 10 cs. capacity as per technical specifications approved by I&WR Department, Haryana and satisfaction of site Engineer.
4Supply of MS Delivery pipe having 7.1 mm thickness, 14’’ diameter along with required M.S. flanges in accordance with IS 2062:1989 Grade-A with two coat of anti corrosive bituminous based paint as per the satisfaction of site Engineer.
5Supply, erection and commissioning of Axial Flow water lubricated V.T. Pumps having discharge of 05 Cs capacity with lift upto 15’, with Y-Body along with bend and operating at speed of 1440 RPM complete in all respect with bends, nipple including jointing with rubber sheets, fabrications, transportation etc. at site as per technical specifications approved by I&WR Department, Haryana and satisfaction of site Engineer.
6Supply of 30 HP motor, 415 volt(+/-10%), 50 Hz (+/-3%), 1440 RPM, 4 Pole IE2, TEFC, continuous duty vertical flange mounted solid shaft squirrel cage, induction motor as per technical specifications approved by I&WR Department, Haryana and satisfaction of site Engineer.
7Providing and commissioning of 30 HP fully automatic star delta starter with MCCB 100 A, 3 pole 25 kA, Contactors, 40A, 40A, 40Amicrocontroller based protection relay, CT’s with all allied accessories with compatible cable upto motor for VT pump of 05 Cs capacity as per technical specifications approved by I&WR Department, Haryana and satisfaction of site Engineer.
8Supply of MS Delivery pipe having 7.1 mm thickness, 12’’ diameter along with required M.S. flanges in accordance with IS 2062:1989 Grade-A with two coat of anti corrosive bituminous based paint as per the satisfaction of site Engineer.
9Supply and fixing of structural steel beams ISMB 300 for mounting/installation of V.T. Pumps in Pump house chamber as per as per the satisfaction of site Engineer.
10S/E/C of LT Distribution Panel having Incomer MCCB of 300Amps, 4 pole, 35 kA and 2 nos. outgoings of 160 Amps, 3 pole 25 kA, 1 No. MCCB of 100A, 3 pole 25 kA along with one No. MCCB of 63A, 4 pole for lighting loads. Auto/manual Capacitor Bank of 50 Kvar in 4 steps having Incomer MCCB of 160 A, Each Stage of Capacitor Bank should have separate MCCB as per specification of HID
116214-ZNR Steel Cage FAG/SKF/KOYO
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail