Supply Of Power Transformer Supply Of Power Transformer For P25 Project At Iocl Panipat Refinery , Supply Of Power Transformer Design, Construction, Assembly, Manufacturing, Painting, Inspection, Testing Of Oil Filled Power Transformer At Vendor’S Work. P, panipat-Haryana

Indian Oil Corporation Limited has published Supply Of Power Transformer Supply Of Power Transformer For P25 Project At Iocl Panipat Refinery , Supply Of Power Transformer Design, Construction, Assembly, Manufacturing, Painting, Inspection, Testing Of Oil Filled Power Transformer At Vendor’S Work. P. Submission Date for this Tender is 17-08-2022. Railway Ancillaries Tenders in panipat Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

32442699
Corrigendum : Supply Of Power Transformer Supply Of Power Transformer For P25 Project At Iocl Panipat Refinery , Supply Of Power Transformer Design, Construction, Assembly, Manufacturing, Painting, Inspection, Testing Of Oil Filled Power Transformer At Vendor’S Work. P
Open Tender
Indian
Haryana
Panipat
17-08-2022

Tender Details

Supply Of Power Transformer Supply Of Power Transformer For P25 Project At Iocl Panipat Refinery , Supply Of Power Transformer Design, Construction, Assembly, Manufacturing, Painting, Inspection, Testing Of Oil Filled Power Transformer At Vendor’S Work. Packing, Supply And Delivery To Site Complete With All Fittings, Accessories And Associated Equipment Which Are Required For Efficient And Trouble Free Operation Supervision Of Installation, Testing And Commissioning Along With Accessories, Commissioning Spares, Special Tools & Tackles And Third Party Inspection For Epcm-2, P25 Project At Iocl Panipat Refinery As Specified In Material Requisition. , Following Transformer(S) Complete With All Accessories In Accordance With These Specifications. A) Tr-118031 & Tr-118032: 2 Nos Transformers (1 Lot) 1. 66/6.9Kv, 25/31.5 Mva, 3-Phase, 50Hz, Impedance As Per Data Sheet, Onan/ Onaf Rating, Oil Immersed, Conservator Type Transformer, On Load Tap Changer (Oltc), Marshalling Box & Cooling Fan Control Cabinet Transformers Shall Be Supplied With First Fill Of Oil And 10% Extra Oil In Non-Returnable Drums. 2. Rtcc Panel (One Per Transformer) 3. Online Pd Monitoring System For Each Transformer, Complete With All Accessories In Accordance With This Specification. 4.Online De-Hydration Facility (Online Removal Of Moisture) Shall Be Provided For Each Transformer With Remote Monitoring System Of All Parameters Complete With All Accessories In Accordance With This Specification. 5. Portable Monitoring, Setting, Analysis & Parameterization Tool (Laptop) With Licensed Copy Of The Operating Softwares For Online Pd Monitoring & Online Dehydration System , Following Transformer(S) Complete With All Accessories In Accordance With These Specifications. A) Tr-119031 & Tr-119032: 2 Nos Transformers (1 Lot) 1. 66/6.9Kv, 16/20 Mva, 3-Phase, 50Hz, Impedance As Per Data Sheet, Onan/ Onaf Rating, Oil Immersed, Conservator Type Transformer, On Load Tap Changer (Oltc), Marshalling Box & Cooling Fan Control Cabinet Transformers Shall Be Supplied With First Fill Of Oil And 10% Extra Oil In Non-Returnable Drums. 2.Rtcc Panel (One Per Transformer) 3.Online Pd Monitoring System For Each Transformer, Complete With All Accessories In Accordance With This Specification 4.Online De-Hydration Facility (Online Removal Of Moisture) Shall Be Provided For Each Transformer With Remote Monitoring System Of All Parameters Complete With All Accessories In Accordance With This Specification. 5.Portable Monitoring, Setting, Analysis & Parameterization Tool (Laptop) With Licensed Copy Of The Operating Softwares For Online Pd Monitoring & Online Dehydration System. , Following Transformer(S) Complete With All Accessories In Accordance With These Specifications. A) Tr-119033 & Tr-119034: 2 Nos Transformers (1 Lot) 1.66/11Kv, 25 Mva, 3-Phase, 50Hz, Impedance As Per Data Sheet, Onan Rating, Oil Immersed, Conservator Type Transformer, Off Circuit Tap Changer (Octc), Marshalling Box & Cooling Fan Control Cabinet. Transformers Shall Be Supplied With First Fill Of Oil And 10% Extra Oil In Non-Returnable Drums. 2.Rtcc Panel (One Per Transformer) 3. Online Pd Monitoring System For Each Transformer, Complete With All Accessories In Accordance With This Specification. 4.Online De-Hydration Facility (Online Removal Of Moisture) Shall Be Provided For Each Transformer With Remote Monitoring System Of All Parameters Complete With All Accessories In Accordance With This Specification. 5.Portable Monitoring, Setting, Analysis & Parameterization Tool (Laptop) With Licensed Copy Of The Operating Softwares For Online Pd Monitoring & Online Dehydration System. => Limited

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 03-08-2022 Addendum_5_EL03_Extn3 Date 17-08-2022
2 08-06-2022 Addendum_1_EL03_Comm_Clar1 Financial Bid 27-06-2022
3 16-06-2022 Addendum_1_EL03_Comm_Clar1 Technical Bid 27-06-2022
4 19-07-2022 Addendum_4_EL03_Extn2 Date 02-08-2022
5 28-06-2022 Addendum_3_EL03_Extn1 Date 18-07-2022

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :