Military Engineer Services-MES has published Improvement To Sports Infrastructure Building Special Repair To Toilet Blocks In Dsc Billets And Upgradation Of Dsc Cook House At Af Station Gwalior Improvement To Sports Infrastructure Building Special Repair To Toilet Blocks In Dsc Billets And Upgradati. Submission Date for this Tender is 12-04-2022. Railway Ancillaries Tenders in gwalior Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

31571769
Corrigendum : Improvement To Sports Infrastructure Building Special Repair To Toilet Blocks In Dsc Billets And Upgradation Of Dsc Cook House At Af Station Gwalior Improvement To Sports Infrastructure Building Special Repair To Toilet Blocks In Dsc Billets And Upgradati
Open Tender
Indian
Madhya Pradesh
gwalior
12-04-2022

Tender Details

Improvement To Sports Infrastructure Building Special Repair To Toilet Blocks In Dsc Billets And Upgradation Of Dsc Cook House At Af Station Gwalior Improvement To Sports Infrastructure Building Special Repair To Toilet Blocks In Dsc Billets And Upgradation Of Dsc Cook House At Af Station Gwalior

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Apr-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 12-04-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 85000.0 /-
Tender Value
INR 42.50 Lakhs /-

BOQ Items

Name of WorkIMPROVEMENT TO SPORTS INFRASTRUCTURE BUILDING, SPECIAL REPAIR TO TOILET BLOCKS IN DSC BILLETS AND UPGRADATION OF DSC COOK HOUSE AT AF STATION GWALIOR
Sl. No. Item Description
1Demolition of PCC in ground floors and pavings not exc 15 cm thickness below or above ground level and removing the debris to a distance not exc 2.5 Km from the starting point. Complete all as specified and directed.
2Demolition of concrete (un-reinforced)of any description and in any position not otherwise specifically provided for complete all as specified and directed.
3M&L for PCC (1:2:4) type B-1, using 20 mm graded stone aggregates, as in kerb/ benching/ coping including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed.
4M&L for 50 mm thick PCC (1:2:4) type B1(20 mm graded stone agg) as in flooring, finished even and smooth without using extra cement and laid in alternate panels with and including 4mm thick glass dividing strips complete all as specified and directed.
5M&L for 75mm thick PCC (1:3:6), type C-2 using 40mm graded stone aggregate as in floor finish laid in alternate bays,surface finished even & smooth without using extra cement, with and including joint filling complete all as specified and directed.
6M&L for PCC (1:4:8) Type D2 (40 mm graded aggre-gate) as in foundations, filling and mass-concretecomplete all as specified and directed.
7S&F vitreous china wash down water closet pan (pedestal pattern), white, with and including plastic water closet seat, white, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device, ( excluding fixing bolts, flushing cistern and flush pipe), including connection to drain (or outgoing pipe) and to flushing pipe, anti -syphonage pipe, etc., completeall as specified and directed.
8S&F seat cover of Vitreous china pedestal pattern water closet (White) with flat bottom including mild steel CP hings complete all as specified anddirected.
9Supply and fix in repairs ofPVC flushing cistern 10 ltr capacity, valve less syphonic action type low level with and incl ball valve float & handle, waste pipe & fixing accesseriesto wall complete all as specified and directed.
10S & F in repairVitreous china wash basin , white , flat back, size 580 x 450 mm, chain and plug and porcelain stopper but incluing brackets, waste pipe and PVC waste coupling and 15 mm bore Pillar Tap, Brass, Chromium Plated, fancy type and cutting for and pinning in ends of brackets or errecting stand, complete all as specified and as directed.
11S&F in repair 15 mm bore brass chromium plated shower rose 125mm size with or without swivel joints and fixing to steel pipe or union complete all as specified and as directed.
12S & F in repair Bib taps, 15 mm dia, cast copper alloy, fancy type with capstan heads ,chromium plated, screwed down , screwed for iron pipe or for brass ferrule and fixed, complete all as specified and as directed.
13S&F in repairs PVC connections 15mm size of PTMT of 450mm long. complete all as specified and directed.
14S&F in repair chromium plated(ABS) faucets with flxible pipe length not less than 1.00M (minium) fixed for EWC/IWC suitable for 15mm bore pipe complete all as specified and as directed.
15S & F in repair fancy type angle stop cock, 15 mm dia, cast copper alloy, with chromium plated, screwed down , high pressure, with capstan head, screwed both ends for iron pipe or for unions and fixed, complete all as specified and as directed.
16S&F in repair 15 mm bore stop valves, fancy type, chromium plated, cast copper alloy, long shank and cup (concealed type) screwed down, high pressure, with crutch handle , screwed externally both ends for unions etc. and fixed complete all as specified and directed.
17S&F in repair rotational moulded polyethylene water storage tank, double layer construction, ISI mark (cylindrical vertical with closed top) hoisted and fixed in position with and including 20 mm dia GI pipe medium grade washout pipe 450 mm long with plug and 20 mm dia GI pipe medium grade overflow pipe 600 mm long with fittings, of 1000 litre capacity of tank completeall as specified and as directed.
18S&F in repair rotational moulded polyethylene water storage tank, double layer construction, ISI mark (cylindrical vertical with closed top) hoisted and fixed in position with and including 20 mm dia GI pipe medium grade washout pipe 450 mm long with plug and 20 mm dia GI pipe medium grade overflow pipe 600 mm long with fittings, of 500 litre capacity of tank completeall as specified and as directed.
19S&F ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed 20mm bore pipe minimum weight 210 gms complete all as specified and as directed.
20Taking up or down 15mm bore steel tubing and connections, including seggregation serviceable pipes cleaning for re-fixing or removal unserviceable pipes from sitecomplete all as specified anddirected.
21Taking up or down 20mm bore steel tubing and connections, including seggregation serviceable pipes cleaning for re-fixing or removal unserviceable pipes from sitecomplete all as specified anddirected.
22Taking up or down 40mm bore steel tubing and connections, including seggregation serviceable pipes cleaning for re-fixing or removal unserviceable pipes from sitecomplete all as specified anddirected.
23S&F GI tubing 15 mm dia bore medium grade with and including all fittings ISI marked and fixed to wall, floor and ceiling etc complete all as specified andasdirected.
24S&F GI tubing 20 mm dia bore medium grade with and including all fittings ISI marked and fixed to wall, floor and ceiling etc complete all as specified andasdirected.
25S&F GI tubing 40 mm dia bore medium grade with and including all fittings ISI marked and fixed to wall, floor and ceiling etc complete all as specified andasdirected.
26Re-fixing of old steel GI tubing, 15mm bore and connections in new or old position (walls, ceiling, floors etc) with and including all new fittings complete all as specified andasdirected.
27Re-fixing of old steel GI tubing, 20mm bore and connections in new or old position (walls, ceiling, floors etc) with and including all new fittings complete all as specified andasdirected.
28Re-fixing of old steel GI tubing, 40mm bore and connections in new or old position (walls, ceiling, floors etc) with and including all new fittings complete all as specified andasdirected.
29S&F in repair PVC grating 100mm dia doom(with waste hole) (Min wt 25 gms) fixed in cement complete all as specified and directed.
30S&F 5mm thick beveled edge best quality looking mirror of size 600x450 mm with 30 mm PVC beading all around the glass, mounted over 5mm thick PVC sheet including frame work around glass and fixed to wooden plugs with chromium plated brass screws and cupwasherscomplete all as specified and directed.
31S&F chromium plated brass tubular towel rail, 20mm dia, D type, 60 cm long between flanges complete all as specified and directed.
32S&F in repair coloured powder coated drapery rod fancy type of aluminium 25mm inner dia design and pattern as approved by GE, over all dia 28-29mm complete all as specified and directed.
33Dismantling floor hearth or wall tiling including cement mortar bedding & removing serviceable material to store and rubbish off the premises complete all as specified anddirected.
34M&L for non skid colouredceramic floor tiles7- 8 mm thick (square/ rectangular) area of each tiles exc. 0.06 sqm but not exc. 0.11 sqm, in floors etc set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over and including 15mm thick screed bed in CM (1:6 )complete all as specified and directed.
35M&L for glazed ceramic tiles 450x300 x 6-7mm thick coloured on vertical surfaces such as skirting/dados etc,set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles overand including rendering 10 mm thick in CM 1:3 on wall complete all as specified and directed.
36Taking down old cement / lime plaster on brick or concrete surfaces etc including racking out joint, hacking for key screbbing down with water etc.complete all as directed.
37Demolition of brick work orstone/ boulder masonry, built in cementmortar including all quoins, pillars etc. and segregation serviceable bricks, keep them staking for re use complete all as directed.
38M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m meanradius builtin cement mortar 1:6 etc,complete all as specified and directed.
39M&L for15mm thickrendering on fair faces of brick work or concrete surface on wallin cement mortar 1:6 finished even and smooth without using extra cement complete all as specified.
40M&L for15mm thickrendering on fair faces of brick work in cement mortar 1:4 finished even and smooth complete all as specified.
41M&L for preparing newly plastered or unplastered surfaces of wall and applying two coats of oil bound distemper over and including one coat of primer and a thing layer of JK/ Birla wall care putty complete all as specified and directed.
42M&L for preparing newly plastered or unplastered surfaces of wall and applying two coats of exterior emulsion paint (Ace paint from Asian Paints or other equivalent brand from Berger/ Shalimar Paints) over and including one coat of primer complete all as specified and directed.
43Dismantling of asbestos cement ( corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
44Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
45M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed.
46M&L for Pre-painted galvalume alu. Zinc coating GI based corrugated steel sheet 0.50 mm thick (total coated thickness) of any colour having tensile strength 550 M pa minimum yield strength as in roof covering fixed using hot dip galvanized self drilling and selftapping screws neoprene and EPDM washers. (Note : minimum, yield strength 550 Mpa with hot dip alloy of 55% Aluminium, 43.5 %zinc, 1.5% Silicon and finished with resin coat on both surfaces)
47M&L for Pre-painted galvalume alu. Zinc coating GI based Plain steel sheet 0.50 mm thick (total coated thickness) of any colour having tensile strength 550 M pa minimum yield strength as in ridges of roof covering fixed using hot dip galvanized self drilling and selftapping screws neoprene and EPDM washers. (Note : minimum, yield strength 550 Mpa with hot dip alloy of 55% Aluminium, 43.5 %zinc, 1.5% Silicon and finished with resin coat on both surfaces)
48Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) of area not exceeding 1.50 Sqm each including cutting holes for taking out hold fast or dismantling brick work & removing from site complete all as specified and directed.
49Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) of area exceeding 1.50 Sqm but not exceeding 4.0 Sqm each including cutting holes for taking out hold fast or dismantling brick work & removing from site complete all as specified and directed.
50S&F for solid PVC door frame of size 50mm x 47 mm made out of 5mm PVC sheet with wood grains printed on if reinforced with MS square tube incl 75mm long MS screws for fixing to walls all as per specified in SSR. complete all as specified .
51S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. M.S frame shall be covered with heat moulded prelaminated colour PVC ‘C’ channel’ having a PVC sheet strip’ of 20mm width stuck inside with solvent cement for stiles and prelaminated colour PVCsheets for top rail lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of prelaminated both side colour PVC sheet to be fitted in the M.S welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, suppling & fixing in the fame at site as per specification & drawing complete all as specified and directed.
52S&F 100 mm long butt hinge, extruded aluminium alloy with galvanized mild steel hinge pin, powder coated of required tint to match shutter and fixed, type B-21 complete all as specified and directed.
53S&F anodised aluminium barrel tower bolts of extruded section of size 150mm complete all as specified and directed.
54S&F anodised aluminium handles cast type of size 150mm complete all as specified and directed.
55S&F galvanised steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or stainless steel wire staples etc. in wooden door / window, completed all as specified and directed.
56M&L for applying two coats of synthetic enamel paint over and including a coat of red oxide primer including preparation of new steel/iron surfaces exceeding 10cm width or girth.complete all as specified.
57M&L for preparation of old painted surface of steel material of any description over 10 cm width or girth and applying two coats of synthetic enamel paintcomplete all as specified and as directed.
58Dismantling of false ceiling of any description and at any height including any type of grid complete all as specified and directed.
59S&F 4 mm thick HPSC pre-prime non asbestos fiber cement building board (E-classic) decorative finish fixed to aluminum or MS galvanised snap grid frame work with hold down clips in ceiling complete all as specified.
60S&F suspended false ceiling grid system of size 600 x 600 mm with main runner of size 32 x 24 x 0.8 mm, cross tee of size 26 x 24x 0.80 mm and wall angle of size 22.2 x 22.2 x 0.65 mm in ceiling suspended @ 1.2m c/c both way with 1.60 mm dia GI wire fixed with steel dash fasterers or from purlin of roof with butterfly clips hold down etc, complete (main runner/ cross tee / wall angle of MS powder coated) as per manufacturere instruction complete all as specified.
61Supplying, fabricating and fixing of aluminium powder coated (minimum thickness of powder coating shall be 50 micron) for door/ window/ ventilator frames, shutters, partitions etc including necessary jointing cleats, glazing clips, aluminium snap beading having minimum weight 100 gram per RM, rubber neoprane gasket, screws, dash fasteners, rawl plug etc complete all as specified and directed. Note: Only weight of aluminium section shall be measured for payment purpose.
62S&F powder coted aluminium grills size exc. 5mmx7.5mm , 8mm thick and aperture n"exc 80mm with and including fixing with aluminium channel, 1mm thick with steel screw and tint match with existing complete all as specified and as directed.
63S&F Mortice latch with two levers (vertical type), mild steel body and fixed 100 mm in size complete all as specified and directed.
64M&L for complete removal of existing treatment of old surface of wall including cornices surfaces by rubbing/sanding and applying two coats of distemper oil emulsion over and incluing one coat of primer andthin layer of JK/ Birla white wall care putty to obtain the desired/ true surface of wall complete all as specified and directed.
65M&L for complete removal of existing treatment of old surface of wall including cornices surfaces by rubbing/sanding and applying two coats of synthetic enamelled paint over and incluing one coat of primer andthin layer of JK/ Birla white wall care putty to obtain the desired/ true surface of wall complete all as specified and directed.
66M&L for complete removal of existing treatment of old surface of wall including cornices surfaces by rubbing/sanding and applying two coats of exterior emulsion paint (Ace paint from Asian Paints or other equivalent brand from Berger/ Shalimar Paints) over and including one coat of suitable primer complete all as specified and directed.
67S&F 4.80 mm thick sheet glass ordinary quality, plain glassaluminium windows/ ventilators etc, in square not exc 0.50 Sqm each pane complete all as specified and directed.
68S&F 6.30 mm thick sheet glass ordinary quality, plain glassaluminium windows/ ventilators etc, in square not exc 0.50 Sqm each pane complete all as specified and directed.
69M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
70M&L for machine pressed precast concrete interlocking paver block60mm thickness, M-35 Grade with grey cement & pigment any shape and size laid in floors and jointsif tiles/blocks to be filled with fine sand and broomed confirming to IS 15658-2006complete all as specified and directed.
71Taking down cement plaster from concrete surfaces including APP membrane etc.complete all as specified and directed.
72M&L for PCC (1:2:4) type B-1, using 20 mm graded stone aggregates, as in levelling course to maintain the true roof slope, roof kerb or mud stop rounded or chamfered edges etc, finished even and fair without using extra cement complete all as specified and directed.
73M&L for 10mm thick screed bed or bedding layer in CM (1:3) mixed withwaterproofing compound as per manufacturers instructions on concrete roof surface finished fair and even to maintain the proper slope of roof surface etc complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately under respective item of BOQ.
74Supply only WPC integral water proofing compound complete all as specified and directed.
75M&L for cutting out cracks to ‘V’ section in existing roof or terracing, cleaning out, wetting and filling solidly a hot mixture of bitumen and dry sand in proportion of 1:1 by weight complete all as specified and as directed
76M&L for applying one coat of cold applied bituminius primer over cleaned surface @ 0.30 Ltr per sqm and one coat of polymeric modified bitumen 85/25 @ 1.2 Kg/Sqm over bituminius primer then followed by APP modified five layer polymeric mambrane 3 mm thick minimum weight 3.5 Kg per Sqm reinfored with polyster non woven fabric (weighting not less than 150 Gm per Sqm) manufactured by M/S STP LTD or its equivelant or IWL or M/S Torchtaro Membranes & Bitumen Products Pvt Ltd laid as per the maufacturer"s instruction with side over lap of 75 mm and end over lap of 100 mm and applying one coat of polymericcc modified bitumen 85/25 @ 1.20 Kg per Sqm finally finished with two coats of aluminium paint @0.20 Litre per sqm for each coat complete all as specified and directed.
77Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed inany mortar complete all as specified and as directed.
78M&L for mirror polished machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and as directed Note:- The size of kota stone slab not less than 550mmx550mm (cut size except the location where balanced.)
79M&L for mirror polished machine cut kota stone 18-20 mm thick as on vertical surfaces such as dado/ skirting etc over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing over and including 10 mm thick screed bed in cement mortar (1:3) complete all as specified and as directed
80S&F 12 mm thick toughened glass as in gates/ door including all necessary fittings and making good the opening complete all as specified and directed.
81M&L for Granite of 18mm to 20mm thick (of any type) work (table rubbed/moulding and polished) in steps, jambs, pillars and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm screed bed in Cement Mortar 1:4 complete all as specified.
82M & L forrendering 10 mm thick in CM 1:3 on concrete surfaces as on ceiling finished even and smooth without using extra cement complete all as specified and directed
83M&L for15mm thickrendering on fair faces of brick work in cement mortar 1:4 mixed with water proofing compound as per manufacturers instructions finished even and smooth complete all as specified. Note: Water proofing compound shall be measured and paid separately under respective item of BOQ.
84M&L for preparing newly plastered / unplastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
85M&L for three coats of white wash on new ceiling surfaces including preparation of surfaces complete all as specified and directed.
86M&L for 25 mm thick PCC, 1:2:4 Mix, Type B0 (Using 12.50 mm graded stone aggregate) as in levelling course complete all as specified and directed.
87M&L for mild steel work as hold fast and similar small article works etc confirming to Fe-290 (Gde E-165) Quality A complete all as specified and directed.
88Supply and fixing of rubber beading 40mm stripin bottom of door complete all as specified and directed.
89S&F plain, solid, straight chowkhats and frames of second class hard wood (Sal), wrought, framed, rebated on the solid, rounded or chamfered, put togather with glue, pinned at joint complete all as specified and directed.
90S&F 35mm thick factory made plain framed, panelled shutters (two panel) of IInd class hard wood rail and styles with lock rail and panel of 9 mm BWP commercial ply. The size of rail and style as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified.
91M&L for PCC (1:3:6) type C-1, using 20mm graded stone aggregate as in filling in hold fast blocks and like etc complete all as specified and directed.
92S&F Factory made solid panel PVC single side prelaminated wire gauzed door shutter i.e. panel will be of wire gauze in lieu of single side prelaminated PVC sheet panel, PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. M.S frame shall be covered with heat moulded plain colour PVC ‘C’ channel’ having a PVC sheet strip’ of 20mm width stuck inside with solvent cement for stiles and prelaminated printed PVCsheets for top rail lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; The wire gauze shall be wrapped on an additional square 8 mm MS solid tube and this tube shall be welded to MS tube. The wire gauze shall be stretched to tighten firmly complete all as specified and directed.
93S&F in repair 18mm thicksolid UPVC ply of1st quality of one side prelaminated of approved colour and one side white colour fixed with screwes, solvent cement /adhesive to make kitchen cabinate and cup board shutterscomplete all as specified and directed.[Make :- Rajshree/Sintex/Polycon]
94S&F in repair 18mm thicksolid UPVC ply of1st quality of both side plain white colour, fixed with screwes, solvent cement /adhesive to makekitchen cabinate sides, top and bottom, shelves inside the cabinet and shutter or drawer complete all as specified and directed. [Make :- Rajshree/Sintex/Polycon]
95S & F continuous (Piano) hinges, mild steel, bright finished or electrogalvanised, width of flap 30 mm (when open), complete all as specified and directed.
96S&F 125 mm long, Hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws, complete all as specified and directed.
97S&F stainless steel magnet catcher for the cupboards/cabinet including all necessary fixing arrangements complete all as specified and directed.
98S&F stainless steel butt hinge of size 100 mm complete all as specified and directed.
99S&F anodised aluminium handles cast type of size 100 mm complete all as specified and directed.
100S&F anodised aluminium sliding door bolt with hasp, staple ( bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of size 250 mm complete all as specified and directed.
101M&L for twocoats of synthetic enamel paint overand including a coat of pink primer including preparation of new wood or wooden base surface over 10cm width or grith complete all as specified and directed.
102S&F 4.00 mm thick sheet glass ordinary quality, plain glassaluminium windows/ ventilators etc, in square not exc 0.50 Sqm each pane complete all as specified and directed.
103S&F mild steel door spring, 200 mm in size, fixed to wooden/ steel frame work with screw/ welding complete all as specified and directed.
104S&F in repairs WC squatting pan “Orissa Pattern” of size 580 x 440mm white with integral foot rest and "S" or "P" traps(cast iron 100mm bore) (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etccomplete all as specified and directed.
105S&F vitreous china urinal half stall type urinal complete including providing and fixing plugs bedding urinal against wall in CM 1:2 securing urinal to plugs with & including 60 mm brass screws pointing around urinal back in cement fixing automatic flushing cistern with brackets flush pipe grating and union for discharge pipe complete all as specified and directed.
106S&F in repair 32 mm dia PVC waste pipe complete all as specified and directed.
107M&L for cast iron floor trap with grating including jointing to waste pipe fixed in PCC (1:2:4) type B1, of 75mm size complete all as specified & directed.
108S&F pressed steel frames made out of 1.25mm thick mild steel sheets for door with one or morerebatesincluding necessary fixing lugs, hinges, lock strike plate etc including one shop coat of red oxideprimer including cutting holes and making goodin PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, of size 125x60mmcomplete all as specified and as directed:- Note : 10mm deformed bar shall be provided in bottom portion in each frame. The rate for the same is included in rate quoted against this item.
109M&L for PCC (1:2:4) using 12.5mm graded stone aggregates, as in filling to hollow sections of pressed steel door frame including necessary formwork complete all as specified and directed.
110S&F 3 mm thick figured glass, pin headed type and glazing with oil putty /wooden beads in square n. exc 0.5 sqm in each pane complete all as specified and as directed.
111Taking down eaves gutters and rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed.
112&F PVC (SWR) pipes single socketed in any length with rubber ring joints and laid in trenches or in floor of size 110 mm bore complete all as specified and as directed.
113S&F PVC (SWR) pipes single socketed in any length with rubber ring joints and fixed to wall of size 110 mm bore complete all as specified and as directed.
114S&F PVC (SWR) bends any radius including necessary cutting in brick wall and making good to match with existing surface of size 110mm bore complete all as specified and as directed.
115S & F 110 mm bore PVC (SWR) branch piece double Y and fixed with adhesive, complete all as specified and as directed.
116S & F 110 mm bore PVC (SWR) single T, fixed with adhesive, complete all as specified and as directed.
117S & F 100 mm bore PVCfloor traps under floor , complete all as specified and as directed.
118S & F 110 mm bore PVCvent cowl complete all as specified and as directed.
119Disconnecting existing water storage tanks of capacity exc. 500 Ltr but n. exc 1000 Ltrs each for repair works and refixing the same tanks in the same postion after the reapir works is carried out complete all as directed. (Note :- The work also includes making the connections of tanks leak proof by replaceing the damaged /rusted GI fittings, refixing of float valvaus and like).
120Disconnecting existing water storage tanks of capacity exc. 250 Ltr but n. exc 500 Ltrs each for repair works and refixing the same tanks in the same postion after the reapir works is carried out complete all as directed. (Note :- The work also includes making the connections of tanks leak proof by replaceing the damaged /rusted GI fittings, refixing of float valvaus and like).
121M&L for PCC (1:5:10) Type E2 (40 mm graded aggre-gate) as in foundations, sunken portion filling and mass-concretecomplete all as specified and directed.
122M&L for 10mm thick cement plaster on fair faces of RCC slab finished fair and smooth in CM 1:3 with water proofing compound complete all as specified and directed.
123M&L for applying evenly a tack coat of industrial bitumen 85/25 @ 1.20 Kg/Sqm incl cleaning of surfaces complete all as specified and directed.
124Taking down carefully existing unserviceable aluminum point wiring of any description & in any position with and includingpvc/steel conduit all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings call bell, lamp holders etc and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as directed. NOTE: Old fittings/fixtures/accessories like switch, sockets, lamp holders, regulators etc found in serviceable condition shall be removed carefully for reuse in the work and shall be paid for separately under appropriate item of Schedule `A’.
125Material and labour for point wiring for one light point or one fan point controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable FR, 1100 volts grade in and including surface PVC conduit (Medium grade) of suitable size not less then 20 mm dia all as directed with using new sunken type pressed steel box/terminal boxes of suitable size, 2mm thick duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings wiring accessories with and including all accessories andusing 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable FR as in earth wire connected to common earth dolly complete all as specified.
126NOTE : (i) The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawl plugs and provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thicklaminated sheet fixed with suitable GI screws and cup washers)(ii)Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of BOQ . (Make of Cable/wire:- : Havells /Finolex/Polycab/Plaza,Make of PVC Conduit:-Finolex/Kalinga/Asian/Jindal/PlazaMake of Laminated Sheet:-Hylam/National/Anchor)
127Material and labour for point wiring for one light point or one fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable FR, 1100 volts grade in and including surface PVC conduit (Medium grade) of suitable size not less then 20 mm dia all as directed with using new sunken type pressed steel box/terminal boxes of suitable size, 2mm thick duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings wiring accessories with and including all accessories andusing 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable FR as in earth wire connected to common earth dolly complete all as specified.
128NOTE : (i) The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawl plugs and provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thicklaminated sheet fixed with suitable GI screws and cup washers)(ii)Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of BOQ . (Make of Cable/wire:- : Havells /Finolex/Polycab/Plaza,Make of PVC Conduit:-Finolex/Kalinga/Asaian/Jindal/PlazaMake of Laminated Sheet:-Hylam/National/Anchor)
129All as per item No 127 here-in-beforebut point wiring for one six pin socket outlet, 15/5 Amps (independent board) controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor
130Material and labour for point wiring for one light point or one fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor cable FR, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including concealed PVC conduit (Medium grade) of suitable size not less then20mm dia all as directed with using new sunken type pressed steel box/terminal boxes of suitable size, 2mm thick duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/junction boxes with and including all accessories andusing 1.5 Sqmm (nominal area) stranded copper conductor cable FR single core. PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed.
131NOTE : (i) The quoted rates shall be deemed to be inclusive for cutting chasesin wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing colour of surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawl plugs and provision of 8covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thicklaminated sheet fixed with suitable GI screws and cup washers)(ii)Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of BOQ (Make of Cable/wire:- : Havells /Finolex/Polycab/GrandlayMake of PVC Conduit:-Finolex/Ess Ess Kay Engineering/Kalinga/Asian/Plaza, Make of Laminated Sheet:-/Hylam/National)
132All as per item No 130 hereinbefore but point wiring for 5 pin switch socket outlet combination, 5/6 Amps on independent board.
133All as per item No 130 hereinbefore but point wiring for one5 pin socket outlet,on same board .
134All as per item No 130 here-in-beforebut point wiring for one six pin socket outlet, 15/5 Amps (independent board) controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor
135M & L forswitch flush type single pole one way 6 Amps, 240 volts, white/ ivory finish complete all as specified.(Make :- Anchor(Panta)/ Cona/ Leader)
136Fixing Onlyswitch flush type single pole one way 6 Amps, 240 volts, white/ ivory finish complete all as specified.
137M & L forswitch flush type single pole one way 16 Amps, 240 volts, white/ ivory finish complete all as specified.(Make :- Anchor(Panta)/ Cona/ Leader)
138M&L for socket outlet 2 in 1, 5 pin, 6 Amps flush type white ivory finish complete all as specified. (Make :- Anchor(Panta) , Cona , Leader)
139S&F switchsocket combination multi purpose, 5 Pin 6 amps, flush typeWith Indicator complete all as specified and directed.Make:-Cat part No 2216 of cona or equivalent of Leader/ Anchor(Panta).
140S&F for switchsocket combination multi purpose, 6 Pin 6/16 amps, flush typeWith Indicator complete all as specified and directed. Make:-Cat part No 2711 of cona or equivalent of Leader/ Anchor(Panta).
141M&L for ceiling rose surface Bakelite three terminal, 18 x 50 mm complete all as specified. (Make :- Anchor(Panta) , Cona , Leader)
142Fixing Only ceiling rose surface Bakelite three terminal, 18 x 50 mm complete all as specified.
143M&L for lamp holder insulated body with back plate for batten fitting complete all as specified.(Make :- Anchor(Panta) , Cona , Leader)
144S&F LED mirror light complete with high output diffuser 2 Feet 10 Watt 220 V AC decorative type complete all as specified and directed. Make: Havells/ CG/Philips
145S&F Street/ Security light fittings, 1X35 Watt, new generation energy saving & enviromental friendly long life versatile pressure die cast aluminium IP66 roadway luminaire with high power LED as light sourcewith acrylic cover suitable for pipe of dia 40 mm (maximum) with and including GI bracket made out of 40 mm dia light grade GI pipe of length 1.20 including necessary nuts, bolts washers and wire of suitable lenght for connection complete all as specified and directed. Make: Havells/ CG/ Surya
146S&F Street/ Security light fittings, 1X15 Watt, new generation energy saving & enviromental friendly long life versatile pressure die cast aluminium IP66 roadway luminaire with high power LED as light sourcewith acrylic cover suitable for pipe of dia 40 mm (maximum) with and including GI bracket made out of 40 mm dia light grade GI pipe of length 1.20 including necessary nuts, bolts washers and wire of suitable lenght for connection complete all as specified and directed. Make: Havells/ CG/ Surya
147S&F LED 120 Watt flood light, 230 Volts, AC, Outdoor type with thermal management in multiple optic and equipped with IP 66 protection with impact and corossion resistant with driver complete all as specified and directed. Make: Havells/ CG/ Surya
148Dismantling & Taking out MCB DBs VTPN any size , any type and capacity and remove materials from site of works. Complete all as directed.
149S&F for sheet metal enclosure Double door for DB’s 4way 240 volts with 200 Amps rated bus bar for single phase and neutral supply complete fixed properly on in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires.Completeall as specified. (Make;ABB,Schneider,Legrand, havells)
150S&F for sheet metal enclosure Double door for DB’s 8way 240 volts with 200 Amps rated bus bar for single phase and neutral supply complete fixed properly on in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires.Completeall as specified. (Make;ABB,Schneider,Legrand, havells)
151S&F in repair factory made epoxy powder coated distribution board TP&N, 4 (Way) (VTPN MCCB DB) with metal door (IP-43 Protection), fabricated from minimum 1.60 mm CRCA sheet and fixed flush to wall and suitable for universal mounting with and including 200 Amp copper bush bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removablr gland plates with knokouts including provision for housing MCCB in the incomimg and MCBs in outgoing complete all as specified and directed. (Make:ABB,Schneider,Legrand, Havells) Note: Old existing MCCB DBs VTPN any type as retrived from site shall be deposited in MES store yard.
152Dismantling & Taking out MCB"s/ Isolatotrs and metal clade box of any size complete all as specified and directed.
153S&F for MCB single pole 6 to 32 Amps, "B" Curve ,240 Volts complete all as specified (Make:Legrand/ABB/Schneider/Havells)
154S&F for MCB Single pole and neutral 40 to 63 Amps 10 KA, "B" series, 240 Volts complete all as specified. (Make:Legrand/ABB/Schneider/Havells )
155S&F MCCB, 3 Pole, 125 Amp, 50 Hz, 415Volts with rupturing capacity 16 KA with thermal magnetic release and adjustable overload setting having type DPX 160 fixed in distribution board complete all as specified and directed. Make: Legrand/Siemens/ABB/Havells
156M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable FR of size 6.0 Sqmm of voltage rating upto and including 1100 Volts drawn in and including surfacePVC conduit med grade of dia not less than 25mm with standard accessories, along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor cable FRof size 6 Sqmm as earth continuity conductor all as specified and directed including taking down old submain wiring with any type of conduit. (NOTE :Two run of single core PVC cable with one run ofearth conductor and conduit shall be measured as one unit.) incl taking out existing sub main wiring with any type of conduit(Make of Cable/wire:- : Havells /Finolex/Polycab/GrandlayMake of PVC Conduit:-Finolex/Ess Ess Kay Engineering/Kalinga/Asian/Plaza
157M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable FR of size 4.0 Sqmm of voltage rating upto and including 1100 Volts drawn in and including surfacePVC conduit med grade of dia not less than 25mm with standard accessories, along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor cable FRof size 4.0 Sqmm as earth continuity conductor all as specified and directed including taking down old submain wiring with any type of conduit. (NOTE :Two run of single core PVC cable with one run ofearth conductor and conduit shall be measured as one unit.) incl taking out existing sub main wiring with any type of conduit(Make of Cable/wire:- : Havells /Finolex/Polycab/GrandlayMake of PVC Conduit:-Finolex/Ess Ess Kay Engineering/Kalinga/Asian/Plaza
158M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable FR of size 6.0 Sqmm of voltage rating upto and including 1100 Volts grade in and including conceled PVC conduit, med grade of size not less then 25 mm bore along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductorof size 6 Sqmm as earth continuity conductor cable FR all as specified and directed including taking down old submain wiring with any type of conduit. Complete all as specified. (NOTE :Two run of single core PVC cable with one run ofearth conductor and conduit shall be measured as one unit.) incl taking out old sub main wiringwith any type of conduit (Make of Cable/wire:- : Havells /Finolex/Polycab/GrandlayMake of PVC Conduit:-Finolex/Ess Ess Kay Engineering/Kalinga/Asian/Plaza
159M&L for single pole and neutral enclosure with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB of capacity 20 Amps, 240 Volts complete fixed on wall by provisioning of suitable sizes of MS strips, nuts, bolts and washersall as specified.(Make:ABB/Schneider/Legrand)
160M&L for earthing complete with MS Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level)with top edge of plate not less than 1.5 mtr below normal ground level including necessary excavation, earth work ,charcoal, salt etc and connected to GI earthing lead wire 4 mm dia by means of GI bolt nuts check nuts washers etc and 20 mm dia GI light grade watering pipe with funnel, wire mesh etc including PCC (1:3:6) type C-1 using 20 mm graded stone aggregate earth pit with 40x40x6 mm mild steel angle iron frame, RCC cover (1:2:4) type B-0, 50 mm thick reinforced with 8 mm dia round bar @100 mm centre to centre both ways with mild steel handle 12 mm dia, plastering 12 mm thick in cement mortar (1:6) internally and upto 150 mm below ground level externally, and GI earth lead wire 4 mm dia and 15 mm dia GI protection pipe medium grade from earth plate to test point upto 7.5m length all as shown in electrical plate No 3 of SSR Part -I 2009 and connected to earth test point including testing completeall as specified& directed. Note: Earth strip and protection pipe upto and including 7.5m deemed included in unit rate quoted by the contractor.
161S&F ON load change over switch, 415 Volts in sheet metal enclosure, 4 Pole of capacity 63 Apm complete all as specified and directed. Make: L&T, C&S, Schneider
162S&F for step type electronic fan regulator single phase ,230 volt, 100/120 watt .Complete all as specified. (Size of PT switch ) Make:-Cat part No 3211of cona or equivalent of Leader/ Anchor(Panta).
163Supply & Fix for decorative slim linear LED tube light fitting 01x20 watt light with co extruded polycarbonate body, environmental frendly, energy efficient ready to use pack with all accessories and connecting the same to ceiling rose with using copper conductor 23/0.0076 flexible PVC sheathsd and fixing arrangement for fixing the light fitting to wall/ roof surface complete all as specified. (Make-Havell"s Cat Part No LUMILINEBS20WLED865SPCWH/Surya Cat No -SLEBT -20 /CG cat No -LCTL 18 CDL)
164S&F for LED bulk head fitting 10 watt energy saving new generation IP 65 luminatre with opel diffuser complete with lamp all as specified. (Make-Havell"s Cat Part No-HEXAFT10WLED857SSYMBOPC/Surya cat Part No -SLE BH-10/ CG Cart Part No -LBHP-10 CDL)
165Taken down carefully ceiling fan/ exhaust fan of any description from existing place and removing to MES store yard and refixing and reconnecting the same after completion of repair work including painting the fan with two coats of synthetic enamelled paint after preparing the surfaces and making connection with and including three core flexible wire 1.50 Sqmm complete all as specified and directed.
166Taken down carefully electric geyser of any description and capacity from existing place and removing to MES store yard and refixing and reconnecting the same after completion of repair work includingmaking connection with suitable wire complete all as specified and directed.
167NOTE:- Site clearance of materials- All demolished material obtained from dismantling/demolition items shall be deposited at place shown by Engr-in-charge properly spread and levelled and site to be cleaned to the entire satisfaction of Engr-in-charge otherwise panel recovery to a sum of Rs. 10000.00 be deducted from dues without any prior intimation.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail