}

Provision Of Store Cum Equipment Test Facility At Chess , Hyderabad, CHESS, HYDERABAD-Telangana

Defence Research And Development Organisation -DRADO has published Provision Of Store Cum Equipment Test Facility At Chess , Hyderabad. Submission Date for this Tender is 14-06-2021. Excavation Work Tenders in CHESS, HYDERABAD Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

27988053
Provision Of Store Cum Equipment Test Facility At Chess , Hyderabad
Open Tender
Indian
Telangana
CHESS, HYDERABAD
14-06-2021

Tender Details

Provision Of Store Cum Equipment Test Facility At Chess , Hyderabad - 2 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. 3 All Kinds Of Soils 4 Excavation Work By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soils As Directed, Within A Lead Of 50 M. 5 Ordinary Rock 6 Hard Rock ( Blasting Prohibited ) 7 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan ) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. 8 All Kinds Of Soils 9 Extra For Every Additional Lift Of 1.5 M Or Part Thereof In Excavation / Banking Nexcavated Or Stacked Materials. 10 All Kinds Of Soils 11 Hard Rock & Ordinary Rock 12 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5 M. 13 Excavating, Supplying And Filling Of Local Earth ( Including Royalty ) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. 14 Credit For Hard Rock Obtained From Above 15 Subhead-Ii :Anti Termite Treatment : 16 Supplying Chemical Emulsion In Sealed Containers Including Delivery As Specified. 17 Chlorpyriphos / Lindane Emulsifiable Concentrate Of 20% 18 Diluting And Injecting Chemical Emulsion For Post-Constructional Anti-Termite Treatment ( Excluding The Cost Of Chemical Emulsion ) : 19 Along The External Wall Below Concrete Or Masonry Apron Using Chemical Emulsion @ 2.25 Litres Per Linear Metre Including Drilling And Plugging Holes Etc., With Chlorpyriphos / Lindane E.C. 20% With 1% Concentration 20 Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 ( 1 Cement : 2 Coarse Sand ) To Match The Existing Floor, With Chlorpyriphos / Lindane E.C. 20% With 1% Concentration 21 Treatment Of Existing Masonry Using Chemical Emulsion @ One Litre Per Hole At 300 Mm Interval Including Drilling Holes At 45 Degree And Plugging Them With Cement Mortar 1:2 ( 1 Cement : 2 Coarse Sand ) To The Full Depth Of The Hole, With Chlorpyriphos / Lindane E.C. 20% With 1% Concentration 22 Subhead-Iii : Plain & Reinforced Cement Concrete : 23 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 24 1:4:8 ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size ) 25 Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls ( Any Thickness ) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Sunken Floor, Etc., Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering And Finishing: 26 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 40 Mm Nominal Size ) 27 Making Plinth Protection 50 Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement: 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Finishing The Top Smooth. 28 Providing And Laying In Position Ready Mixed M-25 Grade Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work, Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying , Excluding The Cost Of Centering, Shuttering Finishing And Reinforcement, Including Cost Of Admixtures In Recommended Proportions As Per Is:9103 To Accelerate / Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of The Engineer - In - Charge. 29 All Works Upto Plinth Level 30 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. 31 ( Note :- Cement Content Considered In This Item Is @ 330 Kg / Cum. Excess / Less Cement Used As Per Design Mix Is Payable / Recoverable Separately ) . N 32 All Works Above Plinth Level Upto Floor V Level 33 Add / Deduct For Using Extra / Less Cement In The Items Of Design Mix Over And Above The Specified Cement Content Therein. N 34 Supplying, Fabricating And Fixing In Position Reinforcement Bars At All Levels And Positions Including The Cost Of Steel, Straightening, Cutting, Bending, Binding And Placing In Position Etc., As Per Drawings And Specifications Including The Cost Of Binding Wire, Labour Etc., All Complete For Reinforced Concrete. 35 Thermo-Mechanically Treated Bars ( Fe 500 Grade ) 36 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : 37 Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete 38 Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers 39 Columns, Pillars, Piers, Abutments, Posts And Struts 40 Weather Shade, Chajjas, Corbels Etc., Including Edges 41 Subhead-Iv : Stone & Brick Masonry : 42 Random Rubble Masonry With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 ( 1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size ) Upto Plinth Level With, Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 43 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) 44 Subhead-V : Plastering & Surface Treatment : 45 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix 1:6 ( 1 Cement: 6 Fine Sand ) 46 18 Mm Cement Plaster In Two Coats Under Layer 12 Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand ) Finished With A Top Layer 6 Mm Thick Cement Plaster 1:6 ( 1 Cement : 6 Fine Sand ) . 47 Extra For Providing And Mixing Water Proofing Material In Cement Plaster Work In Proportion Recommended By The Manufacturers. 48 Providing And Fixing 22 Gauge Chicken Mesh Wire At The Junction Of Rcc And Brick Work With Overlapping Of 100Mm On Both Sides, Etc., Complete. 49 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface 50 Distempering With 1St Quality Acrylic Distemper ( Ready Mixed ) Having Voc Content Less Than 50 Gms / Litre, Of Approved Manufacturer, Of Required Shade And Colour ( Two Or More Coats On New Work ) Complete, As Per Manufacturer’S Specification. 51 Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm / Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade ( Company Depot Tinted ) With Silicon Additives. 52 New Work ( Two Or More Coats Applied @ 1.43 Litre / 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre / 10 Sqm 53 Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms / Sqm ( Both Side Inclusive ) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall / Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of 54 Dry Wall Screws Of Size 3.5 X 25Mm At 230 Mm C / C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound, Jointing Tapes, Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : 55 12.5 Mm Thick Tapered Edge Gypsum Plain Board Conforming To Is: 2095- ( Part I ) : 2011 ( Board With Bis Certification Marks ) 56 Subhead-Vi : Flooring : 57 Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. N40 Mm Thick With 20 Mm Nominal Size Stone Aggregate 58 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. 59 Size Of Tile 600X600 Mm 60 Providing And Laying Vitrified Tiles In Different Sizes ( Thickness To Be Specified By Manufacturer ) , With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) , Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. 61 Size Of Tile 600X600 Mm 62 Subhead-Vii : Steel & Wood Works : 63 Providing And Fixing Anodised Aluminium Grill ( Anodised Transparent Or Dyed To Required Shade According To Is: 1868 With Minimum Anodic Coating Of Grade Ac 15 ) Of Approved Design / Pattern, With Approved Standard Section And Fixed To The Existing Window Frame With C.P. Brass / Stainless Steel Screws @ 200 Mm Centre To Centre, Including Cutting The Grill To Proper Opening Size For Fixing And Operation Of Nhandles And Fixing Approved Anodised Aluminium Standard Section Around The Opening, All Complete As Per Requirement And Direction Of Engineer-In-Charge. ( Only Weight Of Grill To Be Measured For Payment ) . 64 Provision Of Pre-Engineered And Prefabricated Shed Of 10M Span And 4M Height With Structural Trusses, Purlins, Gutters Ridge , Columns Etc., Roof With Pre-Colour Coated Galvalume Sheets Of Apporved Size, Thickness And Make Complete Including Painting And All Necessary Fittings Etc. 65 Providing And Fixing The Following Hardware Fittings Of Approved Make: 66 A ) 200Mm Long Aluminium Tower Bolts 67 B ) Aluminium Aldrop 300Mm Long 68 Providing And Fixing Bright / Matt Finished Aluminium Handles Of Approved Quality & Make With Necessary Screws Etc All Complete. 69 I ) 125Mm Long 70 Providing And Fixing Aluminium Hanging Floor Door Stopper ( Single Rubber Stopper ) , Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete. 71 Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer ( Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm ) , With Necessary Accessories And Screws Etc. Complete. 72 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) : 73 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) , With Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) 74 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge, With Float Glass Panes Of 5 Mm Thickness. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) : With Float Glass Panes Of 5 Mm Thickness ( Weight Not Less Than 12.50 Kg / Sqm ) 75 Subhead - Viii Internal Electrical Work: 76 Lights Points: Nwiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. N ( A ) Group C 77 Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 78 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. N ( A ) Group C 79 Sub Main Wiring: Nwiring For Circuit / Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 80 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 81 Exhaust Fans: Nsupply, Installation & Testing Of Following 900 Rpm Heavy Duty Exhaust Fan Suitable For Single Phase, 240V, Ac Supply Complete With Motor, Ms Louvers, Mounting Brackets All Accessories Etc Complete. 82 300Mm Sweep 83 Wall Mounted Fans: Nsupply And Installation Of Wall Mounted Fans Of Minimum 400Mm Sweep With Atleast 3 Speed, Oscillation And Tilt Mechanisam To Direct Air Where It Is Needed. Including All Accessories Etc., Complete. 84 Ceiling Fans: Nsupply And Fixing Of Ceiling Fan Of Following Sweep ( White Colour ) , Suitable For Operation On 230 / 240V, 50 Hz, Single Phase, A.C, Supply Complete With Double Ball Bearing Motor, Required Down Rod, Capacitor, Three Ms Blades Etc Complete. ( Without Regulator ) 85 1200Mm Sweep 5 Star Rated Ceiling Fans 86 Supplying And Fixing Two Module Stepped Type Electronic Fan, Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 87 Light Fixtures: Nsupply, Installation, Testing & Commissioning Of The Following Light Fixture With Lamp, Control Gear & All Necessary Accessories. Luminaries With All Electrical Accessories & It Should Be Energy Efficient, Etc Are Prewired Up To The Terminal Block & Mounted On A Removable Control Gear Module For Ease Of Maintenance. All Electrical Connections Of The Control Gear Module With The Rest Of The Luminaries Should Be Click Fix & Require Use Of No Tools. Mounting Options Should Be For Both Lateral As Well As Pole Top Mounting With Lamp Control Gear & Fixing Accessories. All Fixtures Shall Be White Colour & Supplied With White Lamps. All The Light Fixtures Will Be Finally Approved By Architect / Consultant / Department. Architect / Consultant / Department Reserves The Right To Reject The Fittings Suggested By The Contractor. ( Makes : Philips / Cg / Wipro / Equivalent ) 88 36 / 40W Led Recessed Mounted Square Light Similar To ( Phillips Cat No. Rc380b Led34s-6500 L60w60 Psd Od S1 Or Wipro Or Equivalent ) . 89 15W Led Downlight Surface Type Light Similar To ( Phillips Cat No. Dn170c Led10s-6500 Psu Wh Or Wipro Or Equivalent ) . 90 20W Led Wp Tube Light Batten Ceiling / Wall Mounted Similar To ( Phillips Cat No-Tcw450 P 1Xtled 19W P3397 Or Wipro Or Equivalent ) 91 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) N N ( A ) 8 Way , Double Door 92 Supplying And Fixing 5 Amps. To 32 Amps. Rating, 240 / 415 V, 10 Ka, `C Series, Miniature Circuit Breaker ( Mcb ) Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. N N ( A ) Single Pole 93 Supplying And Fixing Following Rating, Four / Two Pole 415 Volts, / 220 Volt Residual Current Device ( Rcbo ) Having Earth Leakage, Over Load And Short Circuit Protection At The Incomer Of Existing Distribution Boards Or In Seperate Enclosure, Having A Sensivity Current Of 100 Ma Complete With Connections, Testing And Commissioning Etc. As Required : 94 40A 100Ma 2P Rcbo 95 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 96 25 Mm 97 32 Mm 98 Mv Panels: Nsupply, Installation, Testing And Commissioning Of 3 Phase 415V 4 Wire Free Standing Floor Mounted Indoor Mv Panels Made Out Of 14 Swg Ms Sheet After Seven Tank Process And Painting With Epoxy Powder Coating Including All Switchgear As Detailed Below. This Panel Shall Consist Of Suitable Rating Tpn Aluminium Bus Bar ( At The Rating Of 0.8A / Sqmm ) Supported With Dmc / Smc Barriers And Color Coded With Heat Shrinkable Sleeves. The Metering Shall Be Provided As Specified. This Panel Shall Have Short Circuit Withstanding Capacity Of Minimum 25 Ka And Consist Of The Switchgear As Mentioned Below. This Panel Shall Be Mounted On Channels Including Supply Of The Same. This Panel Shall Be Got Fabricated From Manufacturers With Cpri Test Certificate Only. This Panel Shall Have At Least Two Spare Cubicles Of Maximum Ratings. The Size Of All Panel Mounting Meters Shall Be 96 X 96 Mm. The Panels Shall Be Mounted On U Channels Including Supply And Fixing Of The Same. Every Mccb Shall Be Provided With On / Off / Trip Indication Lamps Of Led Type. For All Electrically Operated Breakers, Local Remote Selector Switches Shall Be Provided For Controlling The Breakers Remotely. 99 Building Panel: Nincoming : N125a, 25Ka 4P Mccb With O / C, S / C, E / L Termal Magnetic Based Release – 1 No Nbusbars: N125a Tp+N Aluminum Bus Bar – 1 Set Neb Meterings : N0-500V Digital Voltmeter With Selector Switch And Mcb Control- 1Set. N0-125A Digital Ammeter With Resin Cast Cts Of Ratio 125 / 5A Class 1 Accuracy And 15Va Burden With Selector Switch-1 Set. Nled Phase Indication Lamps With Individuals Mcbs And Control With Toggle Switches With Mfm Meter- 1 Set Ncbct With Earth Leakage Relay – 1 Set N 100 Outgoings: N63a, 25Ka Tpn Mccb With On, Off & Trip Lamps– 3 Nos N32a, 25Ka Tpn Mccb With On, Off & Trip Lamps– 3Nos N40a, 10Ka Dp Mcb C Curve With On, Off Lamps–2Nos 25A, 10Ka Dp Mcb C Curve With On, Off Lamps–2Nos N 101 Supply Installation Testing And Commissioning Of Tpn 63A Mccb In An Enclosure With All Required Accessories Etc Complete. 102 Subhead-Ix Air Conditioning 103 Supply, Insallation, Testing And Commissioning Of Dx Type Hiwall Split Airconditioners ( Inverter Type ) Electrical Driven With One Outdoor & One Indoor Unit With Cordless Remote, Standard Lenghth Of Copper Pvc Pipes & Cabling Suitable For Operation On 230 Volt, 50 Hz, Single Phase Ac Supply With All Required Accessories Etc Complete. 104 2.0Tr Capacity 105 Supply, Installation, Testing And Commissioning Of Following Size Hard Copper Piping For Condenser Units With Insulation Of 19Mm Thick Nitrile Rubber Pre Formed Sections Including Supporting Fixtures And Accessories Etc., Complete. 106 9.5 Mm 107 15.9 Mm 108 Supply & Installation Of Cabling To Be Properly Laid In 25Mm Dia Heavy Guage Pvc Conduit Of Copper 3 Core 1.5 Sqmm As Per The Approved Routing 109 Supply & Installation 25Mm Cpvc Drain Piping With Suitable Supports As Required & Insulated With 6Mm Thick Nitrile Rubber Insulation. 110 Subhead -X Power Wiring: 111 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5 / 6 A Modular Socket Outlet And 5 / 6 A Modular Switch, Connections Etc. As Required. 112 Supply And Fixing Of Modular Type Single Phase 2 Nos Of 6A 5 Pin Socket With 6A Switch With Front Plate And Anodized Gi Box Including All Fixing Accessories. 113 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 A Modular Socket Outlet And 15 / 16 A Modular Switch, Connections Etc. As Required. 114 Circuit Wiring: Nwiring For Circuit / Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 115 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 116 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire 117 4 X 6Sq. Mm + 2 X 6 Sq. Mm Earth Wire 118 4 X 16Sq. Mm + 2 X 6 Sq. Mm Earth Wire 119 Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator. ) 120 8 Way ( 4 + 24 ) , Double Door 121 Supplying And Fixing 5 Amps. To 32 Amps. Rating, 240 / 415 V, 10 Ka, `C Series, Miniature Circuit Breaker ( Mcb ) Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 122 Single Pole 123 Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 100 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 124 40A 125 Supplying And Fixing Following Rating, Four Pole, ( Three Phase And Neutral ) , 415 Volts, Mcb In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 126 63 A 127 Subhead - Xi Telephone & Lan Conduiting 128 Supply And Fixing Of Telephone Outlet ( Rj11 ) With Anodised Gi Box With Front Plate Etc. Complete As Required. 129 Supply And Laying Of Following Pair 0.5Mm Dia Pvc Insulated Unarmoured Copper Conductor Telephone Wire In Existing Conduit Conforming To Dot Specifications. ( A ) 2 Pair 130 Supply And Installation Of Following Size Krone Connectors In Ms Box Complete As Required. 131 10 Pair Tag Block 132 Supply And Laying Of Following Pair 0.5Mm Dia Jelly Filled Armoured Copper Conductor Telephone Cable In Shaft Existing Cable Tray With All Fixing Accessories. The Cable Shall Be As Per The Dot Specifications. 133 10 Pair 134 Supply And Fixing Of Data Outlet ( Rj45 ) With Anodised Gi Box With Front Plate Etc. Complete As Required 135 Supply And Laying Of Utp 4 Pair Cat 6 Lan Cable In Existing Conduit Complete As Required. 136 Supply , Installation , Testing And Commissioning Of Krone Mdf With Module, Connectors With Accessories. 137 10 Pair 138 Subhead - Xii Shop Electrics: 139 Supply And Fixing Of Factory Made 1-Phase 16 / 20 A Sp Metalclad Socket With 20A Dp Mcb In Ms Box Including All Fixing Accessories. ( For Acs - 2Nos & General - 4 Nos. ) 140 Supply And Fixing Of Factory Made 3-Phase 32 A Tpn+E Metalclad Socket With 32A Tp Mcb In Ms Box Including All Fixing Accessories. 141 Supply And Fixing Of Factory Made 3-Phase 63 A Tpn+E Metalclad Socket With 63A Tp Mcb In Ms Box Including All Fixing Accessories. 142 Subhead - Xiii Special Earthing: 143 Supply, Erection, Testing And Commissioning Of Maintenance Free Earth Station With Consisting Of - 65Mm Dia, Standard Length ( As Per Equipment Supplier ) Electrode Capsule, Filled With Earth Enhancing Compound, Seald At Both Ends And Brazed Lead For Connection At One End, Suitable For Direct Installation At Site, At A Depth Of 2.5Mtrs. Earth Enhancement Compound Upto A Depth Of 2.0Meters Arround The Electrode Capsule. Brick Chamber & Ci Cover Complete. 144 Supplying And Laying 25 Mm X 5 Mm Copper Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection / Terminating With Nut, Bolt, Spring, Washer Etc. As Required. ( Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm ) 145 Supplying And Laying 25 Mm X 5 Mm Copper Strip Run In Floor / Trenches Along With Dmc Insulated Supports With Necessary Interconnections With Earth Station And Equipments. 146 Subhead - Xiv Lightning Protection: 147 Supply Gi Electrode Earthing With 40 Mm Dia And 3 Meter Length, The Electrode Should Be Hot-Dip Galvanized With Upto 120 Micron. The Gi Strip In Pipe Electrode Shall Be Pre-Filled With Crystalline Conductive Material ( Ccm ) . The Gi Electrode Shall Be Surrounded With 50 Kg Jam Fill Compound To Provide Maximum Contact Between The Electrode And The Soil. Backfill Compound Should Be Eco-Friendly And Having Rohs Certification. Gi Electrode Earthing Should Be Maintenance Free And Dose Not Required Regular Manual Addition Of Water. Gi Electrode Shall Be Tested From Cpri. The Earthing Pit Should Be Cover With Frp Pit Cover Of 300X300mm Bottom And 200X200m With 150Mm Height In Green Colour. As Per Jam 193. 148 Supply And Laying Of Following Size Earth Strips The Same Shall Be Laid At A Depth Of 750Mm Below Ground Level Including Excavation And Refilling Of Earth Necessary Interconnections With Earth Station And Equipments. 149 50 X 6 Mm Gi Strip Laid In Ground 150 Supply And Laying Of Following Size Earth Strips With All Fixing Accessories When Laid On The Parapet & Terrace With Necessary Interconnections With Earth Station And Equipments. 151 25X5mm Aluminium Strip Conductor With Dmc Insulated Supports 152 Supply And Installation Of Vertical Air Termination With 40Mm Dia Copper Hollow Sphere With Spikes, Fixed On 1000Mm Length, 25Mm Dia Copper Rod Including Pcc Block And All Fixing Accessories. 153 Subhead- Xv External Power Supply: 154 1.1Kv Cables: Supply Of Following Size 1.1Kv Grade Xlpe Insulated Armoured Aluminium / Copper Conductor Cable. The Cable Shall Conform To Is 7098. 155 3.5C X 95 Sq.Mm Ar.Al 156 4C X 6 Sq.Mm Cu 157 4C X 4 Sq.Mm Cu 158 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation And Refilling The Trench Etc As Required, But Excluding Sand Cushioning And Protective Covering. 159 Up To 35 Sqmm 160 Above 35 Sq. Mm And Upto 95 Sq. Mm 161 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required. 162 Up To 35 Sqmm 163 Above 35 Sq. Mm And Upto 95 Sq. Mm 164 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc / Hume / Metal Pipe As Required. 165 Up To 35 Sqmm 166 Above 35 Sq. Mm And Upto 95 Sq. Mm 167 Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Cable Tray As Required. 168 ( A ) Upto 35 Sq. Mm ( Clamped With 1Mm Thick Saddle ) 169 ( B ) Above 35 Sq. Mm And Upto 95 Sq. Mm ( Clamped With 25X3mm Ms Flat Clamp ) 170 Supplying And Fixing Cable Route Marker With 10 Cm X 10 Cm X 5 Mm Thick G.I. Plate With Inscription There On, Bolted / Welded To 35 Mm X 35 Mm X 6 Mm Angle Iron, 60 Cm Long And Fixing The Same In Ground As Required. 171 End Terminations: Nsupplying And Making End Termination With Brass Compression Gland And Aluminium / Copper Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 172 Indoor: 173 3.5C X 95 Sq.Mm Al 174 4C X 6 Sq.Mm Cu 175 4C X 4 Sq.Mm Cu 176 Supply And Fixing Of Following Size Gi Perforated Type Cable Tray Made Out Of 2Mm Thick Sheet With Gi Covers Including Ms Supports For Fixing The Tray, Anchor Fasteners Etc Complete As Required. 177 300Mm Wide X 75 Mm Depth 178 150Mm Wide X 75 Mm Depth 179 100Mm Wide X 50 Mm Depth 180 50Mm Wide X 25 Mm Depth 181 Earthing: 182 Supply, Erection, Testing And Commissioning Of G.I. Earth Station, With 40Mm Dia 2500Mm Long Gi Pipe, Including Construction Of Brick Pedestal, Providing Meshed , Ci Cover And Other Civil Engineering Works, Spreading A Homogenous Mixture Of Salt, Charcoal Around The Pipe Etc, Completely As Per Is 3043, 1987 Or Latest Revision. 183 Supply, Erection, Testing And Commissioning Of Conventional Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, Excavation, Refilling And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required As Per Is-3043 / 87 With Latest Amendments. 184 Providing And Fixing 25 Mm X 5 Mm Copper Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With Brass Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. 185 Supplying And Laying 25 Mm X 5 Mm G.I Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection / Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. ( Jointing Shall Be Done By Overlapping And With 2 Sets Of G.I. Nut Bolt & Spring Washer Spaced At 50Mm ) 186 8 Swg Gi Wire 187 Supply, Installation, Testing And Commissioning Of Extension Panel At The Existing Main Lt Panel Consist Of 1 No. Of Tpn 630A, 36Ka Mccb & 1 No. Of Tpn 125A, 25Ka Mccb By Making Suitable Bus Extension For Existing 1000A Suitable Bus Bar And Addition Of Atleast 4 Cubicles Along With Bus Bar Chamber & Cable Chamber For These New Outgoings With All Required Modification , Liasion For Shut Down Etc Complete. ( Two Will Be With 125 A & 630 A Each And Other Two Will Be Vacant ) With All Required Accessories Etc Complete In Existing Substation As Required Or As Directed By Engineer-In-Charge.

Key Value

Document Fees
INR 500 /-
EMD
INR 91740.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail