Repair/Replacement/ Conversion Of Led Lights And Ceiling Fittings , Earthing , Lightning Protection System And Connected Work Tech Bldgs , Solar Water Heater , Pipe Lines And Connected Work At Airmen Billets , Snco , Airmen And Officers Mess At Biht

Tender Notice

25809884
Repair/Replacement/ Conversion Of Led Lights And Ceiling Fittings , Earthing , Lightning Protection System And Connected Work Tech Bldgs , Solar Water Heater , Pipe Lines And Connected Work At Airmen Billets , Snco , Airmen And Officers Mess At Biht
Indian
Bihar
22-10-2020
10-11-2020
12-11-2020

Tender Details

Repair/Replacement/ Conversion Of Led Lights And Ceiling Fittings , Earthing , Lightning Protection System And Connected Work Tech Bldgs , Solar Water Heater , Pipe Lines And Connected Work At Airmen Billets , Snco , Airmen And Officers Mess At Bihta

Key Value

Document Fees
INR 500 /-
EMD
INR 19000.00 /-
Tender Value
Refer document

BOQ Items

Name of Work : Repair/Replacement/ conversion of LED lights and ceiling fittings, Earthing, lightning protection system and connected work tech bldgs, solar water heater, pipe lines and connected work at Airmen billets, SNCO’s, Airmen and officer’s mess at AF Stn Bihta under GE (AF) Bihta
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down existing unserviceable surface /batten fitting fixtures complete all as specified and directed by Engineer -in-charge 556 per point
2 2 Fixing only 20 watt LED PC Batten light Fitting ,Compact appearance,simple in nature d complete all as specified and directed ( Note :LED light fitting shall be issued under Schedule 'B' free for Fixing) 330 Each
3 3 S & F TRIMLINE 10 watt LED Batten light Fitting complete with upto 100 Lm/W suitable for 230 Volts,50 Hz AC supply complete all as specified and directed. Make:CG Cat Pat No. LDL-10-CDL or equivelent make and model of BAJAJ/PHILLIPS/Havells 166 Each
4 4 S&F STUD 10 W LED energy saving bulkhead lumanaries including taking down old one complete all as specified and directed. Make: CG Cat Pat No LBHP-10-CDL or equivelent make and model of PHILLIPS/HAVELLS 60 Each
5 5 M & L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanised iron or steel including excavation and earth work, GI pipe medium grade 15 mm bore for protection of GI wire from earth electrode to test point /machinery / equipment. supplying and laying charcoal dust comman salt PCC (1:2:4) type B1 using 20 mm graded crushed stone agregrate chamber and RCC cover 54 cm X 54cm x50 mm thick (1:2:4) type B-1 using 20 mm graded crushed stone aggregates, reinforced with 8 mm dia TMT bars @ 75mm C/C both ways with mild steel handle 12 mm dia, using round bar ,PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No-3 of SSR part-1 and testing on completionincludingd taking out the old unserviceable one complete all as specified and directed. Note - Cost of GI wire and GI protection pipe up to a distance 7.5 M shall be included in quated rate of above Items.Note : Rate for taking down of old unsv earthing upto ground level may also be includ in quoting rate). 15 Each Set
6 6 M& L Air termination single pointed aluminium rod 12mm dia and 300 mm long including taking out old unsreviceable one complete all as specified and directed. 10 Each
7 7 M&L Air termination single pointed copper rod 12mm dia and 300 mm long including taking out old unsreviceable one complete all as specified and directed. 10 Each
8 8 M&L aluminium strip 25mm x 3.15mm with saddles and fixing screws for roof conductors and down conductors above ground including taking unserveciable one complete all as specified and directed.Note : Aluminium strip should be of complete Roll of standard length and not in pieces. 200 RM
9 9 M&L copper strip 20mm x 3.15mm with saddles and fixing screws for roof conductors and down conductors above ground including taking unserveciable one complete all as specified and directed. Note :- Copper strip should be of complete Roll of standard length and not in pieces. 50 RM
10 10 M & L GI strip 32mm x 6mm buried in ground including taking out old unserviceable one complete all as specified and directed. 25 RM
11 11 M & L test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw including taking out unsrviceable one complete all as specified and directed. 15 Each
12 12 M & L for laying 40mm bore tube ,light grade galvanised with all fittings laid in trenches or fixed to walls complete all as specified and directed. 50 RM
13 13 M & L for replacement of broken /britle/unsv PVC/China clay wall grip suitable for fixing of vertical conductor including steel screw 3'' complete all asspecified and directed. 200 Each
14 14 Supply and fixing in replacement of old unsv Building light controller of any type into Single phase 3 KW (Swadeep-66-3 KW 1P) with contactor, Incoming MCB & Outgoing MCB rating of 20-25 Amps & main load circuit wiring (copper) of min size 10 Sqmm. The Automatic street light control switch using Infrared sensor based nature switch for automatic switching of street lights. Nature switch operation should be based on natural light lux level. Required illuminance level for switching ON is =30 Lux and for switching OFF =Lux. The sensor should also have part night operation facility of minimum 4 hrs to max 12 hrs. The sensor alongwith suitable power contactor(s) and incoming and outgoing MCBs should be enclosed in a pole /wall mountable Rust Proof, Electric shock proof, Terminate proof and FR grade IP66 protection class 2 Enclosure made of thermoplastic polycorbonate and protected against weather influences. The circuit should have provision for manual operation (i,e Sensor By-Pass option). Make of panel consisting of (i) Nature switch -Healer (ii) Contactors - BCH (iii) MCBs - Hager (iv) Enclosure - Hensel, (v) Circuit wiring - Polycab. (vi) Contactor should confirm to IEC-60947-4-1/IS-13947-4-1 and MCBs should conform to IEC-60898/IS-8828. 1 Each
15 15 All as per item serial item no 14 hereinbefore but for 3 phase Swadeep 66 Series of Max load 8 KW (32 Amps/Phase) Model SWADEEP-66-8KW3P 1 Each
16 16 M & L for laying/ fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 10 Sqmm 2 core complete all as specified and directed. Make : Plaza/Havells/Polycab 50 RM
17 17 S & F in repair GI tubing 15mm bore medium grade galvanised with all fittings, fixtures and fixed in wall and ceiling or laid in floor complete all as specified and as directed. 30 RM
18 18 S & F in repair GI tubing 20mm bore medium grade galvanised with all fittings, fixtures and fixed in wall and ceiling or laid in floor complete all as specified and as directed. 30 RM
19 19 S & F in repair GI tubing 25mm bore medium grade galvanised with all fittings, fixtures and fixed in wall and ceiling or laid in floor complete all as specified and as directed. 30 RM
20 20 S & F in repair hot water pipe line 15mm bore insulated with glass wool and aluminium cladding complete all as specified and directed. 60 RM
21 21 S & F in repair gun metal globe or gate valve of following sizes with cast iron wheel head screwed both ends for iron pipe complete all as specified and as diected :-(a) 15mm dia bore 5 Each
22 22 (b) 20mm bore 5 Each
23 23 (c) 25mm bore 5 Each
24 24 S & F in repair 15mm bib tap cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed. 6 Each
25 25 S & F in repair isolator/MCB SPN 40 Amps with MCB DB 220 volts 2 way complete all as specified and as directed. 6 Each
26 26 S & F in repair isolator/MCB TPN 32 Amps with MCB DB 220 volts 4 way complete all as specified and as directed. 6 Each
27 27 S & F in repair Solar flat plate collector (Panel) for 100 LPD Non standard 1 No complete all as as directed 2 Each
28 28 S & F in repair Solar flat plate collector (Panel) for 200 LPD Non standard 1 No and standard 1 No complete all as directed 1 Each
29 29 S & F in repair Solar flat plate collector (Panel) for 300 LPD Non standard 1 No and standard 2 No complete all as directed 1 Each
30 30 S & F in repair solar water heater storage tank for 100 LPD including making necessary Elect and water supply connections and testing etc complete all as specified and as directed. 2 Each
31 31 S & F in repair solar water heater storage tank for 200 LPD including making necessary Elect and water supply connections and testing etc complete all as specified and as directed. 2 Each
32 32 S & F in repair solar water heater storage tank for 300 LPD including making necessary Elect and water supply connections and testing etc complete all as specified and as directed. 1 Each
33 33 S & F in repair hot water out let hose pipe of standard length. 3 Each
34 34 S & F in repair cold water in let hose pipe of standard length. 3 Each
35 35 S & F in repair heating element with rubber gasket threaded /push type, 230 Volts, 1.5/2.00 KW and making necessary electrical connections, testing complete all as directed. Make of element : Toshiba/Bajaj or equivalent. 2 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2020 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail