Rajasthan Police Housing & Construction Corporation Limited has published Supply Installation Testing And Commissioning Of Audio , Video Recording Equipments In Interrogation Room At New Building Of Anti Corruption Bureau Jaipur .. Submission Date for this Tender is 26-10-2020. Audio Video Equipment Tenders in Ajmer Rajasthan. Bidders can get complete Tender details and download the document.
Name of Work : | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Note:\n1. Banas Sand/ Sota Nallha washed sand / Roopangarh sand / Massi sand will be permitted after proper quality test from RRVPNL lab.\n2. Water shall be provided free of cost if available at site at one point nearer to the water source.\n3. Cube moulds and testing of mortar as well as for concrete arranged by the contractor at site at his own cost for proper quality measures by the department. All the cubes shall be transported on time by the contractor upto Sub Div. Office Bharatpur at his own cost.\n4. Prior to the start of the work sand, bricks and aggregate shall be dually tested and samples shall be arranged by the contractor in presence of JEN/AEN upto the Sub Div. office Bharatpur. | 1 | 13 | P.Cum |
2 | 2 | Part- A : Building work | 2 | 14 | P.Cum |
3 | 3 | B-3/3.2.7:-Providing and laying in position cement concrete including curing. Compaction etc. Complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size.) | 3 | 15 | P.Cum |
4 | 4 | B-3/3.2.2 :- Providing and laying in position cement concrete including curing. Compaction etc. Complete in specified grade excluding the cost of centering and shuttering - All work up toplinth level M-20 grade nominal mix (with graded stone aggregate 20 mm nominal size) | 4 | 16 | P.Cum |
5 | 5 | B-5/5.17:-Brick masonry in super structure upto third storey with bricks of class designation 75 in cement mortar 1:6(1 cement:6 coarse sand | 5 | 17 | P.Cum |
6 | 6 | B-14.54 Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50meter lead | 6 | 18 | P.Cum |
7 | 7 | B-12/12.9.2&3 :- Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished | 7 | 19 | P.Cum |
8 | 8 | a -20 mm thick | 8 | 20 | P.Cum |
9 | 9 | B-5.8.4.+5.9 : Half brick masonary in super structure using bricks of designation 75. Cement mortar 1 : 6 ( 1 cement : 6 Coarse sand). | 9 | 21 | P.Cum |
10 | 10 | B-6/ 6.16.4 : Supplying and fixing in walls machine cut and polished stone shelves, tands and sills in CM 1 : 3 with machine cut edges. Kota stone 25 to 30 mm thick. | 10 | 22 | P.Cum |
11 | 11 | B-12/12.44.2 : White washing with lime to give an even shade including all scaffolding : Old work (two or more coats)including scrapping old surface and repairing with whiting whereever necessary | 11 | 23 | P.Cum |
12 | 12 | B-12/12.47.1 :- Color washing of all shades to give an even shade including all scaffolding : New work (two or more coats) with a coat of white washing with lime. | 12 | 24 | P.Cum |
13 | 13 | B-12/12.53.1 :- Finishing wall with water proofing cement paint or approved brand and manufacture and or required shade to give and even shade to give all scaffolding : New work (Three or more coats). | 13 | 25 | P.Cum |
14 | 14 | B-12/12.68.1 :- Painting with enamel paint of approved brand and manufacture to give and even shade : Two or more coats on new work. | 14 | 26 | P.Cum |
15 | 15 | B-12/12.68.1 :- Painting with enamel paint of approved brand and manufacture to give and even shade : One or more coats on old work. | 15 | 27 | P.Cum |
16 | 16 | S/3.19.3 : P & F rigid PVC pipe (IS : 4985 mark) class II (4 KG./cm 2) approved quality/ make including joining the pipe with solvent cement rubber ring and lubricant : | 16 | 28 | P.Cum |
17 | 17 | (b) 110 mm dia. | 17 | 29 | P.Cum |
18 | 18 | E020100 :- Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sq. Mm FR PVC insulated unsheathed flexible copper earth conductor 1.1 KV grade (IS : 694) of approved make in surface/ recessed ISI marked medium duty PVC conduit & it’s accessories, round tiles, 18 SWG MS box with earth terminal, screwless cage connectors for netural looping in switch. 3.0 mm thick phenolic laminated sheet, zinc plated/ brass screws, cup washers, making connections, testing etc, as required (Group 2) | 18 | 30 | P.Cum |
19 | 19 | (a) E020101 : Short point (up to 3 Mtr.) | 19 | 31 | P.Cum |
20 | 20 | (b) E020102 : Medium point (up to 6 Mtr.) | 20 | 32 | P.Cum |
21 | 21 | (c) E020103 : Long point (up to 10 Mtr.) | 21 | 33 | P.Cum |
22 | 22 | E020301 :- Wiring of 3 pin 5 amp. Light plug point with 1.5 sq. Mm FR PVC insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq mm FR PVC insulated unsheathed flexible copper earth conductor 1.1 kv grade (IS : 694) of approved make in surface/ recessed ISI marked medium duty PVC conduit & it’s accessories, round tiles 18 SWG MS box with earth terminal, screwless cage connectors for netural looping in switch board & falce ceiling point, 6 A switch 6 A scoket. 3.0 mm thick phenolic laminated sheet, zinc plated/ brass screws, cup washers, making connections, testing etc, as required on board. (Group 2) | 22 | 34 | P.Cum |
23 | 23 | E040100 :- Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS : 694) of 11 kv grade and approved make in existing surface or recessed conduit/ casing capping including making conne-ctions etc. as required (Group 1) | 23 | 35 | P.Cum |
24 | 24 | (a) E040108 : 2 X 2.5 sq.mm + 1.5 sq. mm | 24 | 36 | P.Cum |
25 | 25 | (b) E040117 : 2 X 4.0 sq. mm +2.5 sq. mm | 25 | 37 | P.Cum |
26 | 26 | E 072200-P/F ISI marked flush type 120/280 watt rotary step fan regulator i/c makin connection testin etc. as required Gr-2 | 26 | 38 | P.Cum |
27 | 27 | E071000-P&F ISI marked (IS:1293) 3 pin 6 amp. Porcelain base tumbler socket including making connection testing etc. as required (Gr.2) | 27 | 39 | P.Cum |
28 | 28 | E070300-P&F ISI marked (IS 3854) 6A flush type switch including cutting hole in tile and making connection testing etc. as required. Group-2 | 28 | 40 | P.Cum |
29 | 29 | E04000 :- Supplying and fixing of power plug point accessories on 18 SWG metal box of size 175 X 100 X 60 mm on surface or in recessed with suitable size phenolic laminated sheet cover including cost of 6 pin 16 amp. Switch and socket outlet, making connection, testing etc. as required (Group 2). | 29 | 41 | P.Cum |
30 | 30 | E060112 :- P & F 240/415 V MCB of breaking capacity not less than 10 KA (B/C/D tripping characteristic) ISI marked IS 8828 (1996)/ conforming to IEC 60898 in existing board/ sheets including making connections with lugs, testing etc. as required : 6 A to 32 A rating (Group 2) | 30 | 42 | P.Cum |
31 | 31 | E060211 : P & F 240/415 V isolator conforming to IS : 13947 – III/ IEC 60947-3 on existing board/ sheet including making connections with lugs. Testing etc. As required : 30 A/ 40 A rating. (Group 2). | 31 | 43 | P.Cum |
32 | 32 | E060512 :- P & F recessed/ surface mounting heavy duty horizontal type sheet steel distribution board phophatised/powder painted complete with copper bus bas, shorting ling, neutral link, earth link and din bar, conforming to IS 13032 & IS 8623 including making internal DB terminations with copper lugs, testing etc, as required : 6 way (Group 2) | 32 | 44 | P.Cum |
33 | 33 | E071400 : P & F IS : 371 marked 6 amp surface type ceiling rese including making connection testing etc. as required. (Group 2) | 33 | 45 | P.Cum |
34 | 34 | E071500 :- P & F ISI marked 6 amp Bakelite batten/ angle holder including making connection testing etc. as required. (Group 2) | 34 | 46 | P.Cum |
35 | 35 | E190103 : P & F strip type fluore scent tube fitting fabricated from (CRCA sheet and finished with powder coating/ stove enamelled paint)/ (extruded non corrosive UV resist EP channel) complete with accessories like (OCCB, starter, seat)/ EB, rotor holder, terminal block duly prewired with copper conductor including making connection, testing etc. as required (without tube) : 1 x 36 watts with EB. (Group 2). | 35 | 47 | P.Cum |
36 | 36 | E 200101 : P & F IP-43 protected street light luminaire on existing bracket suitable for FTL. Made out from CRCA sheet steel finished with stove enamelled paint, having deep drawn aluminium alloy canopy reflector cum control gear tray, clear ribbed acrylic diffuser held with synthetic gasket, with all necessary accessories copper wound ballast, capacitor, starter, holder prewired with pvc insulated copper conductor including making connection testing etc. as required. (without tube) : 1 X 36 watt GR 2. | 36 | 48 | P.Cum |
37 | 37 | E 190712 :- P & F fluorescent tube rod in existing fixtures as required : 36/ 40 watts. (Group 2) | 37 | 49 | P.Cum |
38 | 38 | E171001-P & F of heavy duty capacitor start,double ball bearing 900/1400 RPM single phase ISI marked exhaustfan ,IS : 2312 marked in existing opening including making connection teting etc. as required . 300 mm sweep (900/1400 RPM) GR-2 | 38 | 50 | P.Cum |
39 | 39 | E150100-Pipe Earthing as per IS:3043 with preforated 3.0Mtr. Long, 40 mm dai. 'B' class G.I. pipe including all accessories like nut, bolts, reducer, nipple,wire meshed funnel, and C.C. finished chember covered with hinged type with locking arrengement C.I. cover, C.I. frame of size 300 mm x 330 mm and embodeying the pipe comlete with alternate layers salt and coke/charcoal, testing of earth resistance as required. | 39 | 51 | P.Cum |
40 | 40 | E150703- S & Laying following size earth wire / strip in horizontal or vertical run in ground / surface /recess including riveting soldering , saddles, making connection etc. as requred. 8 SWG G.I. (Hot Dipped) wire. | 40 | 52 | P.Cum |
41 | 41 | E150802- S &Laying following size 'B' class G.I. pipe conferming to IS : 1239 P-1 (1990) with accessories for lating earth condector / strip/cable in ground/surface /recees as required. 20 mm dai. | 41 | 53 | P.Cum |
42 | 42 | S-2/2.2.1 : P&F GI pipes (external work)with GI fittings (IS:1239 Mark) includind trenching and refilling earth etc : 15 mm dia nominal bore | 42 | 54 | P.Cum |
43 | 43 | S-2/2.7.5: P&F bibcock (IS:8931 Mark) superior quality of approved make : CP Brass Long body 15 mm nominal bore weight not less than 690 gm. | 43 | 55 | P.Cum |
44 | 44 | S-2/2.13.3 : P & F 15 mm DIa connection pipe of approved quality/ make : PVC pipe with CP Brass nuts up to length 450 mm. | 44 | 56 | P.Cum |
45 | 45 | S-2/2.15 : P & F Full way Valve ( IS : 778 Mark) or wheel Valve of approved make. | 45 | 57 | P.Cum |
46 | 46 | (a). Gunmetal 15 mm nominal bore. | 46 | 58 | P.Cum |
47 | 47 | (b). Gunmetal 25 mm nominal bore. | 47 | 59 | P.Cum |
48 | 48 | S-2/2.26.2 : P & F PVC storage Tank (IS : 12701 marked indication the BIS license No.), of approved make with cover, 25 mm dia IM long GI over flowipe & 25 cm. Long wash out pipe with plug & socket, including making connection etc. complete of approved design : 300 litres capacity. | 48 | 60 | P.Cum |
49 | 49 | S-2/2.12.1 : P & F Inlet connection (Angle valves) Superior quality, of approved make for Washbasin, Gyset etc : CP Inlet connection 15 mm Brass (IS : 8931 marked) | 49 | 61 | P.Cum |
50 | 50 | S-3.20.-P & F rigid PVC pipe (IS:4985 mark) of approved quality /make including jointing of pipe with solvent cement rubber ring and lubricant. | 50 | 62 | P.Cum |
51 | 51 | (b)Bend 87.5 -110 mm dia | 51 | 63 | P.Cum |
52 | 52 | B-14.57.1 Dismantling roofs with care incluidng stacking of serviceable material and disposal of unserviceable material with in 50mtr. Lead for : (Lime terrace.) | 52 | 64 | P.Cum |
53 | 53 | B-15.17.2-Grading for roof water proofing treatment Cement concrete 1 : 2 : 4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) with watre proofing compound as per manufacture's specification | 53 | 65 | P.Cum |
54 | 54 | B-14.56.3 :- Dismantling of cement concrete flooring with care including stacking jof serviceable material with in 50 Mtr. Lead | 54 | 66 | P.Cum |
55 | 55 | B-12.48-Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repair to scratches by sandla/loi.(only for colour change) | 55 | 67 | P.Cum |
56 | 56 | B-10.8 Providing batta ( gola) 75mm X 75mm in cement concrete ( 1:2:4) including fineshing with cement mortar 1:3 as per standard design. | 56 | 68 | P.Cum |
57 | 57 | B-12.5-:Applying Birla/JK White cement based putty over cement plaster surface for making even surface | 57 | 69 | P.Cum |
58 | 58 | B-12/12.51.1:-Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: New work (two or more coats) over and including scrapping and priming coat with cement primer | 58 | 70 | P.Cum |
59 | 59 | B-7/ 7.7 : P & F vitrified porcelain polished (Naveen/ Euro make, size 600 mm x 600 mm and thickness 10 mm) on floor, skirting and steps etc. Laid wth tie admixture (Roff pidlite or equivalent) including filling of joints by water proofing tile grout (Fevimate, Roofie, Untile or equivalent) specially for adhesive with grade granuals, polymer and stable pigment fine finished including cleaning of joints etc. complete as per direction of Engineer Incharge. | 59 | 71 | P.Cum |
60 | 60 | B-11/11.57.1 : Providing and fixing of precast concrete interlocking blocks of M 30 grade 80 mm thick manufactured from fully computerised automatic stationery hydraulic vibropressed machine and fully computerised automatic batching plant of class A1/A2 as per BS 6717 : 2001. The CC interlocking paving blocks be laid on average 50 mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer in charge. The rates to be inclusive of all lead. Lifts and taxes General spectification of blocks . 1. Shape as defined by Engineer in charge. 2. Tensile splitting strength and braking load as per BS 6717 : 2001 . 3. Color Grey cement natural colour. 4. Variation in dimension Less than 1.6 mm. 5. Variation in thickness Less than 3.2 mm. 6. Abrasion As per BS : 6717 : 2001 | 60 | 72 | P.Cum |
61 | 61 | B-9/9.4.1- Structural steel work Welded in built up sections, trusses and framed work, including cutting , hoisting , fixinn in position and applyng a priming coat of approved steel primer all complete above plinth upto 4.5 mtr height. In flats , tees, angles and channels. | 61 | 73 | P.Cum |
62 | 62 | B-9/9.19.1 :- P&F steel gate grating and grills made of angles tees square bars or other flats black pipe with hold fasts and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide.Add extra if square,rectangular hollow tubelar sections are used | 62 | 74 | P.Cum |
63 | 63 | B-10/10.50.3-P & F Plain fiber glass sheet (FRP sheet fiber Reinforcement product steel confirming to IS-12866-1989 having minimum thickness as below including fixing with nuts ,bolts,hooks and bitumin washer etc. complete. 3.0 mm thick (wt 8.4 kg/mtr. sq) | 63 | 75 | P.Cum |
64 | 64 | 3.3.3 Providing and laying cement concrete including curing , compaction etc. complete in retaining walls ,walls (any thickness) including atteched pilasters, columnc ,piers, abutments,pillars,posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks,anchor blocks, plain window sills, fillets etc up to floor three level excluding the cost of centering and shuttering.1:2:4 (1 cement :2 coarse sand:a graded stone aggregate 20 mm nominal size) | 64 | 76 | P.Cum |
65 | 65 | B-1/1.8 :- Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms lift up to 1.5 mtr taking out the excavated soil and depositing & refilling of Jhiri with watering and ramming & disposal of surplus excavated soil as directed with in a lead of 50 Mtr. All kinds of soil. | 65 | 77 | P.Cum |
66 | 66 | B-10.1.1-Stone slabroofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both side in cement sand moratar 1:4 ,ralthal,stone kharanja,lime terracing 90 mm average thickness (as per jaipur practice)with ceiling pointing in cement sand mortar 1:3 complete as per specification for span up to 2.0 mtr | 66 | 78 | P.Cum |
67 | 67 | B-14.57.2 :- Dismantling roofs with care including stacking of serviceable material and disposal of universable material with in 50 mtr. Lead for : | 67 | 79 | P.Cum |
68 | 68 | Note:\n1. Banas Sand/ Sota Nallha washed sand / Roopangarh sand / Massi sand will be permitted after proper quality test from RRVPNL lab.\n2. Water shall be provided free of cost if available at site at one point nearer to the water source.\n3. Cube moulds and testing of mortar as well as for concrete arranged by the contractor at site at his own cost for proper quality measures by the department. All the cubes shall be transported on time by the contractor upto Sub Div. Office Bharatpur at his own cost.\n4. Prior to the start of the work sand, bricks and aggregate shall be dually tested and samples shall be arranged by the contractor in presence of JEN/AEN upto the Sub Div. office Bharatpur. | 68 | 13 | P.Cum |
69 | 69 | Part- A : Building work | 69 | 14 | P.Cum |
70 | 70 | B-3/3.2.7:-Providing and laying in position cement concrete including curing. Compaction etc. Complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size.) | 70 | 15 | P.Cum |
71 | 71 | B-3/3.2.2 :- Providing and laying in position cement concrete including curing. Compaction etc. Complete in specified grade excluding the cost of centering and shuttering - All work up toplinth level M-20 grade nominal mix (with graded stone aggregate 20 mm nominal size) | 71 | 16 | P.Cum |
72 | 72 | B-5/5.17:-Brick masonry in super structure upto third storey with bricks of class designation 75 in cement mortar 1:6(1 cement:6 coarse sand | 72 | 17 | P.Cum |
73 | 73 | B-14.54 Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50meter lead | 73 | 18 | P.Cum |
74 | 74 | B-12/12.9.2&3 :- Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished | 74 | 19 | P.Cum |
75 | 75 | a -20 mm thick | 75 | 20 | P.Cum |
76 | 76 | B-5.8.4.+5.9 : Half brick masonary in super structure using bricks of designation 75. Cement mortar 1 : 6 ( 1 cement : 6 Coarse sand). | 76 | 21 | P.Cum |
77 | 77 | B-6/ 6.16.4 : Supplying and fixing in walls machine cut and polished stone shelves, tands and sills in CM 1 : 3 with machine cut edges. Kota stone 25 to 30 mm thick. | 77 | 22 | P.Cum |
78 | 78 | B-12/12.44.2 : White washing with lime to give an even shade including all scaffolding : Old work (two or more coats)including scrapping old surface and repairing with whiting whereever necessary | 78 | 23 | P.Cum |
79 | 79 | B-12/12.47.1 :- Color washing of all shades to give an even shade including all scaffolding : New work (two or more coats) with a coat of white washing with lime. | 79 | 24 | P.Cum |
80 | 80 | B-12/12.53.1 :- Finishing wall with water proofing cement paint or approved brand and manufacture and or required shade to give and even shade to give all scaffolding : New work (Three or more coats). | 80 | 25 | P.Cum |
81 | 81 | B-12/12.68.1 :- Painting with enamel paint of approved brand and manufacture to give and even shade : Two or more coats on new work. | 81 | 26 | P.Cum |
82 | 82 | B-12/12.68.1 :- Painting with enamel paint of approved brand and manufacture to give and even shade : One or more coats on old work. | 82 | 27 | P.Cum |
83 | 83 | S/3.19.3 : P & F rigid PVC pipe (IS : 4985 mark) class II (4 KG./cm 2) approved quality/ make including joining the pipe with solvent cement rubber ring and lubricant : | 83 | 28 | P.Cum |
84 | 84 | (b) 110 mm dia. | 84 | 29 | P.Cum |
85 | 85 | E020100 :- Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sq. Mm FR PVC insulated unsheathed flexible copper earth conductor 1.1 KV grade (IS : 694) of approved make in surface/ recessed ISI marked medium duty PVC conduit & it’s accessories, round tiles, 18 SWG MS box with earth terminal, screwless cage connectors for netural looping in switch. 3.0 mm thick phenolic laminated sheet, zinc plated/ brass screws, cup washers, making connections, testing etc, as required (Group 2) | 85 | 30 | P.Cum |
86 | 86 | (a) E020101 : Short point (up to 3 Mtr.) | 86 | 31 | P.Cum |
87 | 87 | (b) E020102 : Medium point (up to 6 Mtr.) | 87 | 32 | P.Cum |
88 | 88 | (c) E020103 : Long point (up to 10 Mtr.) | 88 | 33 | P.Cum |
89 | 89 | E020301 :- Wiring of 3 pin 5 amp. Light plug point with 1.5 sq. Mm FR PVC insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq mm FR PVC insulated unsheathed flexible copper earth conductor 1.1 kv grade (IS : 694) of approved make in surface/ recessed ISI marked medium duty PVC conduit & it’s accessories, round tiles 18 SWG MS box with earth terminal, screwless cage connectors for netural looping in switch board & falce ceiling point, 6 A switch 6 A scoket. 3.0 mm thick phenolic laminated sheet, zinc plated/ brass screws, cup washers, making connections, testing etc, as required on board. (Group 2) | 89 | 34 | P.Cum |
90 | 90 | E040100 :- Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS : 694) of 11 kv grade and approved make in existing surface or recessed conduit/ casing capping including making conne-ctions etc. as required (Group 1) | 90 | 35 | P.Cum |
91 | 91 | (a) E040108 : 2 X 2.5 sq.mm + 1.5 sq. mm | 91 | 36 | P.Cum |
92 | 92 | (b) E040117 : 2 X 4.0 sq. mm +2.5 sq. mm | 92 | 37 | P.Cum |
93 | 93 | E 072200-P/F ISI marked flush type 120/280 watt rotary step fan regulator i/c makin connection testin etc. as required Gr-2 | 93 | 38 | P.Cum |
94 | 94 | E071000-P&F ISI marked (IS:1293) 3 pin 6 amp. Porcelain base tumbler socket including making connection testing etc. as required (Gr.2) | 94 | 39 | P.Cum |
95 | 95 | E070300-P&F ISI marked (IS 3854) 6A flush type switch including cutting hole in tile and making connection testing etc. as required. Group-2 | 95 | 40 | P.Cum |
96 | 96 | E04000 :- Supplying and fixing of power plug point accessories on 18 SWG metal box of size 175 X 100 X 60 mm on surface or in recessed with suitable size phenolic laminated sheet cover including cost of 6 pin 16 amp. Switch and socket outlet, making connection, testing etc. as required (Group 2). | 96 | 41 | P.Cum |
97 | 97 | E060112 :- P & F 240/415 V MCB of breaking capacity not less than 10 KA (B/C/D tripping characteristic) ISI marked IS 8828 (1996)/ conforming to IEC 60898 in existing board/ sheets including making connections with lugs, testing etc. as required : 6 A to 32 A rating (Group 2) | 97 | 42 | P.Cum |
98 | 98 | E060211 : P & F 240/415 V isolator conforming to IS : 13947 – III/ IEC 60947-3 on existing board/ sheet including making connections with lugs. Testing etc. As required : 30 A/ 40 A rating. (Group 2). | 98 | 43 | P.Cum |
99 | 99 | E060512 :- P & F recessed/ surface mounting heavy duty horizontal type sheet steel distribution board phophatised/powder painted complete with copper bus bas, shorting ling, neutral link, earth link and din bar, conforming to IS 13032 & IS 8623 including making internal DB terminations with copper lugs, testing etc, as required : 6 way (Group 2) | 99 | 44 | P.Cum |
100 | 100 | E071400 : P & F IS : 371 marked 6 amp surface type ceiling rese including making connection testing etc. as required. (Group 2) | 100 | 45 | P.Cum |
101 | 101 | E071500 :- P & F ISI marked 6 amp Bakelite batten/ angle holder including making connection testing etc. as required. (Group 2) | 101 | 46 | P.Cum |
102 | 102 | E190103 : P & F strip type fluore scent tube fitting fabricated from (CRCA sheet and finished with powder coating/ stove enamelled paint)/ (extruded non corrosive UV resist EP channel) complete with accessories like (OCCB, starter, seat)/ EB, rotor holder, terminal block duly prewired with copper conductor including making connection, testing etc. as required (without tube) : 1 x 36 watts with EB. (Group 2). | 102 | 47 | P.Cum |
103 | 103 | E 200101 : P & F IP-43 protected street light luminaire on existing bracket suitable for FTL. Made out from CRCA sheet steel finished with stove enamelled paint, having deep drawn aluminium alloy canopy reflector cum control gear tray, clear ribbed acrylic diffuser held with synthetic gasket, with all necessary accessories copper wound ballast, capacitor, starter, holder prewired with pvc insulated copper conductor including making connection testing etc. as required. (without tube) : 1 X 36 watt GR 2. | 103 | 48 | P.Cum |
104 | 104 | E 190712 :- P & F fluorescent tube rod in existing fixtures as required : 36/ 40 watts. (Group 2) | 104 | 49 | P.Cum |
105 | 105 | E171001-P & F of heavy duty capacitor start,double ball bearing 900/1400 RPM single phase ISI marked exhaustfan ,IS : 2312 marked in existing opening including making connection teting etc. as required . 300 mm sweep (900/1400 RPM) GR-2 | 105 | 50 | P.Cum |
106 | 106 | E150100-Pipe Earthing as per IS:3043 with preforated 3.0Mtr. Long, 40 mm dai. 'B' class G.I. pipe including all accessories like nut, bolts, reducer, nipple,wire meshed funnel, and C.C. finished chember covered with hinged type with locking arrengement C.I. cover, C.I. frame of size 300 mm x 330 mm and embodeying the pipe comlete with alternate layers salt and coke/charcoal, testing of earth resistance as required. | 106 | 51 | P.Cum |
107 | 107 | E150703- S & Laying following size earth wire / strip in horizontal or vertical run in ground / surface /recess including riveting soldering , saddles, making connection etc. as requred. 8 SWG G.I. (Hot Dipped) wire. | 107 | 52 | P.Cum |
108 | 108 | E150802- S &Laying following size 'B' class G.I. pipe conferming to IS : 1239 P-1 (1990) with accessories for lating earth condector / strip/cable in ground/surface /recees as required. 20 mm dai. | 108 | 53 | P.Cum |
109 | 109 | S-2/2.2.1 : P&F GI pipes (external work)with GI fittings (IS:1239 Mark) includind trenching and refilling earth etc : 15 mm dia nominal bore | 109 | 54 | P.Cum |
110 | 110 | S-2/2.7.5: P&F bibcock (IS:8931 Mark) superior quality of approved make : CP Brass Long body 15 mm nominal bore weight not less than 690 gm. | 110 | 55 | P.Cum |
111 | 111 | S-2/2.13.3 : P & F 15 mm DIa connection pipe of approved quality/ make : PVC pipe with CP Brass nuts up to length 450 mm. | 111 | 56 | P.Cum |
112 | 112 | S-2/2.15 : P & F Full way Valve ( IS : 778 Mark) or wheel Valve of approved make. | 112 | 57 | P.Cum |
113 | 113 | (a). Gunmetal 15 mm nominal bore. | 113 | 58 | P.Cum |
114 | 114 | (b). Gunmetal 25 mm nominal bore. | 114 | 59 | P.Cum |
115 | 115 | S-2/2.26.2 : P & F PVC storage Tank (IS : 12701 marked indication the BIS license No.), of approved make with cover, 25 mm dia IM long GI over flowipe & 25 cm. Long wash out pipe with plug & socket, including making connection etc. complete of approved design : 300 litres capacity. | 115 | 60 | P.Cum |
116 | 116 | S-2/2.12.1 : P & F Inlet connection (Angle valves) Superior quality, of approved make for Washbasin, Gyset etc : CP Inlet connection 15 mm Brass (IS : 8931 marked) | 116 | 61 | P.Cum |
117 | 117 | S-3.20.-P & F rigid PVC pipe (IS:4985 mark) of approved quality /make including jointing of pipe with solvent cement rubber ring and lubricant. | 117 | 62 | P.Cum |
118 | 118 | (b)Bend 87.5 -110 mm dia | 118 | 63 | P.Cum |
119 | 119 | B-14.57.1 Dismantling roofs with care incluidng stacking of serviceable material and disposal of unserviceable material with in 50mtr. Lead for : (Lime terrace.) | 119 | 64 | P.Cum |
120 | 120 | B-15.17.2-Grading for roof water proofing treatment Cement concrete 1 : 2 : 4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) with watre proofing compound as per manufacture's specification | 120 | 65 | P.Cum |
121 | 121 | B-14.56.3 :- Dismantling of cement concrete flooring with care including stacking jof serviceable material with in 50 Mtr. Lead | 121 | 66 | P.Cum |
122 | 122 | B-12.48-Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repair to scratches by sandla/loi.(only for colour change) | 122 | 67 | P.Cum |
123 | 123 | B-10.8 Providing batta ( gola) 75mm X 75mm in cement concrete ( 1:2:4) including fineshing with cement mortar 1:3 as per standard design. | 123 | 68 | P.Cum |
124 | 124 | B-12.5-:Applying Birla/JK White cement based putty over cement plaster surface for making even surface | 124 | 69 | P.Cum |
125 | 125 | B-12/12.51.1:-Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: New work (two or more coats) over and including scrapping and priming coat with cement primer | 125 | 70 | P.Cum |
126 | 126 | B-7/ 7.7 : P & F vitrified porcelain polished (Naveen/ Euro make, size 600 mm x 600 mm and thickness 10 mm) on floor, skirting and steps etc. Laid wth tie admixture (Roff pidlite or equivalent) including filling of joints by water proofing tile grout (Fevimate, Roofie, Untile or equivalent) specially for adhesive with grade granuals, polymer and stable pigment fine finished including cleaning of joints etc. complete as per direction of Engineer Incharge. | 126 | 71 | P.Cum |
127 | 127 | B-11/11.57.1 : Providing and fixing of precast concrete interlocking blocks of M 30 grade 80 mm thick manufactured from fully computerised automatic stationery hydraulic vibropressed machine and fully computerised automatic batching plant of class A1/A2 as per BS 6717 : 2001. The CC interlocking paving blocks be laid on average 50 mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer in charge. The rates to be inclusive of all lead. Lifts and taxes General spectification of blocks . 1. Shape as defined by Engineer in charge. 2. Tensile splitting strength and braking load as per BS 6717 : 2001 . 3. Color Grey cement natural colour. 4. Variation in dimension Less than 1.6 mm. 5. Variation in thickness Less than 3.2 mm. 6. Abrasion As per BS : 6717 : 2001 | 127 | 72 | P.Cum |
128 | 128 | B-9/9.4.1- Structural steel work Welded in built up sections, trusses and framed work, including cutting , hoisting , fixinn in position and applyng a priming coat of approved steel primer all complete above plinth upto 4.5 mtr height. In flats , tees, angles and channels. | 128 | 73 | P.Cum |
129 | 129 | B-9/9.19.1 :- P&F steel gate grating and grills made of angles tees square bars or other flats black pipe with hold fasts and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide.Add extra if square,rectangular hollow tubelar sections are used | 129 | 74 | P.Cum |
130 | 130 | B-10/10.50.3-P & F Plain fiber glass sheet (FRP sheet fiber Reinforcement product steel confirming to IS-12866-1989 having minimum thickness as below including fixing with nuts ,bolts,hooks and bitumin washer etc. complete. 3.0 mm thick (wt 8.4 kg/mtr. sq) | 130 | 75 | P.Cum |
131 | 131 | 3.3.3 Providing and laying cement concrete including curing , compaction etc. complete in retaining walls ,walls (any thickness) including atteched pilasters, columnc ,piers, abutments,pillars,posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks,anchor blocks, plain window sills, fillets etc up to floor three level excluding the cost of centering and shuttering.1:2:4 (1 cement :2 coarse sand:a graded stone aggregate 20 mm nominal size) | 131 | 76 | P.Cum |
132 | 132 | B-1/1.8 :- Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms lift up to 1.5 mtr taking out the excavated soil and depositing & refilling of Jhiri with watering and ramming & disposal of surplus excavated soil as directed with in a lead of 50 Mtr. All kinds of soil. | 132 | 77 | P.Cum |
133 | 133 | B-10.1.1-Stone slabroofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both side in cement sand moratar 1:4 ,ralthal,stone kharanja,lime terracing 90 mm average thickness (as per jaipur practice)with ceiling pointing in cement sand mortar 1:3 complete as per specification for span up to 2.0 mtr | 133 | 78 | P.Cum |
134 | 134 | B-14.57.2 :- Dismantling roofs with care including stacking of serviceable material and disposal of universable material with in 50 mtr. Lead for : | 134 | 79 | P.Cum |
135 | 135 | Note:\n1. Banas Sand/ Sota Nallha washed sand / Roopangarh sand / Massi sand will be permitted after proper quality test from RRVPNL lab.\n2. Water shall be provided free of cost if available at site at one point nearer to the water source.\n3. Cube moulds and testing of mortar as well as for concrete arranged by the contractor at site at his own cost for proper quality measures by the department. All the cubes shall be transported on time by the contractor upto Sub Div. Office Bharatpur at his own cost.\n4. Prior to the start of the work sand, bricks and aggregate shall be dually tested and samples shall be arranged by the contractor in presence of JEN/AEN upto the Sub Div. office Bharatpur. | 135 | 13 | P.Cum |
136 | 136 | Part- A : Building work | 136 | 14 | P.Cum |
137 | 137 | B-3/3.2.7:-Providing and laying in position cement concrete including curing. Compaction etc. Complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size.) | 137 | 15 | P.Cum |
138 | 138 | B-3/3.2.2 :- Providing and laying in position cement concrete including curing. Compaction etc. Complete in specified grade excluding the cost of centering and shuttering - All work up toplinth level M-20 grade nominal mix (with graded stone aggregate 20 mm nominal size) | 138 | 16 | P.Cum |
139 | 139 | B-5/5.17:-Brick masonry in super structure upto third storey with bricks of class designation 75 in cement mortar 1:6(1 cement:6 coarse sand | 139 | 17 | P.Cum |
140 | 140 | B-14.54 Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50meter lead | 140 | 18 | P.Cum |
141 | 141 | B-12/12.9.2&3 :- Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished | 141 | 19 | P.Cum |
142 | 142 | a -20 mm thick | 142 | 20 | P.Cum |
143 | 143 | B-5.8.4.+5.9 : Half brick masonary in super structure using bricks of designation 75. Cement mortar 1 : 6 ( 1 cement : 6 Coarse sand). | 143 | 21 | P.Cum |
144 | 144 | B-6/ 6.16.4 : Supplying and fixing in walls machine cut and polished stone shelves, tands and sills in CM 1 : 3 with machine cut edges. Kota stone 25 to 30 mm thick. | 144 | 22 | P.Cum |
145 | 145 | B-12/12.44.2 : White washing with lime to give an even shade including all scaffolding : Old work (two or more coats)including scrapping old surface and repairing with whiting whereever necessary | 145 | 23 | P.Cum |
146 | 146 | B-12/12.47.1 :- Color washing of all shades to give an even shade including all scaffolding : New work (two or more coats) with a coat of white washing with lime. | 146 | 24 | P.Cum |
147 | 147 | B-12/12.53.1 :- Finishing wall with water proofing cement paint or approved brand and manufacture and or required shade to give and even shade to give all scaffolding : New work (Three or more coats). | 147 | 25 | P.Cum |
148 | 148 | B-12/12.68.1 :- Painting with enamel paint of approved brand and manufacture to give and even shade : Two or more coats on new work. | 148 | 26 | P.Cum |
149 | 149 | B-12/12.68.1 :- Painting with enamel paint of approved brand and manufacture to give and even shade : One or more coats on old work. | 149 | 27 | P.Cum |
150 | 150 | S/3.19.3 : P & F rigid PVC pipe (IS : 4985 mark) class II (4 KG./cm 2) approved quality/ make including joining the pipe with solvent cement rubber ring and lubricant : | 150 | 28 | P.Cum |
151 | 151 | (b) 110 mm dia. | 151 | 29 | P.Cum |
152 | 152 | E020100 :- Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sq. Mm FR PVC insulated unsheathed flexible copper earth conductor 1.1 KV grade (IS : 694) of approved make in surface/ recessed ISI marked medium duty PVC conduit & it’s accessories, round tiles, 18 SWG MS box with earth terminal, screwless cage connectors for netural looping in switch. 3.0 mm thick phenolic laminated sheet, zinc plated/ brass screws, cup washers, making connections, testing etc, as required (Group 2) | 152 | 30 | P.Cum |
153 | 153 | (a) E020101 : Short point (up to 3 Mtr.) | 153 | 31 | P.Cum |
154 | 154 | (b) E020102 : Medium point (up to 6 Mtr.) | 154 | 32 | P.Cum |
155 | 155 | (c) E020103 : Long point (up to 10 Mtr.) | 155 | 33 | P.Cum |
156 | 156 | E020301 :- Wiring of 3 pin 5 amp. Light plug point with 1.5 sq. Mm FR PVC insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq mm FR PVC insulated unsheathed flexible copper earth conductor 1.1 kv grade (IS : 694) of approved make in surface/ recessed ISI marked medium duty PVC conduit & it’s accessories, round tiles 18 SWG MS box with earth terminal, screwless cage connectors for netural looping in switch board & falce ceiling point, 6 A switch 6 A scoket. 3.0 mm thick phenolic laminated sheet, zinc plated/ brass screws, cup washers, making connections, testing etc, as required on board. (Group 2) | 156 | 34 | P.Cum |
157 | 157 | E040100 :- Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS : 694) of 11 kv grade and approved make in existing surface or recessed conduit/ casing capping including making conne-ctions etc. as required (Group 1) | 157 | 35 | P.Cum |
158 | 158 | (a) E040108 : 2 X 2.5 sq.mm + 1.5 sq. mm | 158 | 36 | P.Cum |
159 | 159 | (b) E040117 : 2 X 4.0 sq. mm +2.5 sq. mm | 159 | 37 | P.Cum |
160 | 160 | E 072200-P/F ISI marked flush type 120/280 watt rotary step fan regulator i/c makin connection testin etc. as required Gr-2 | 160 | 38 | P.Cum |
161 | 161 | E071000-P&F ISI marked (IS:1293) 3 pin 6 amp. Porcelain base tumbler socket including making connection testing etc. as required (Gr.2) | 161 | 39 | P.Cum |
162 | 162 | E070300-P&F ISI marked (IS 3854) 6A flush type switch including cutting hole in tile and making connection testing etc. as required. Group-2 | 162 | 40 | P.Cum |
163 | 163 | E04000 :- Supplying and fixing of power plug point accessories on 18 SWG metal box of size 175 X 100 X 60 mm on surface or in recessed with suitable size phenolic laminated sheet cover including cost of 6 pin 16 amp. Switch and socket outlet, making connection, testing etc. as required (Group 2). | 163 | 41 | P.Cum |
164 | 164 | E060112 :- P & F 240/415 V MCB of breaking capacity not less than 10 KA (B/C/D tripping characteristic) ISI marked IS 8828 (1996)/ conforming to IEC 60898 in existing board/ sheets including making connections with lugs, testing etc. as required : 6 A to 32 A rating (Group 2) | 164 | 42 | P.Cum |
165 | 165 | E060211 : P & F 240/415 V isolator conforming to IS : 13947 – III/ IEC 60947-3 on existing board/ sheet including making connections with lugs. Testing etc. As required : 30 A/ 40 A rating. (Group 2). | 165 | 43 | P.Cum |
166 | 166 | E060512 :- P & F recessed/ surface mounting heavy duty horizontal type sheet steel distribution board phophatised/powder painted complete with copper bus bas, shorting ling, neutral link, earth link and din bar, conforming to IS 13032 & IS 8623 including making internal DB terminations with copper lugs, testing etc, as required : 6 way (Group 2) | 166 | 44 | P.Cum |
167 | 167 | E071400 : P & F IS : 371 marked 6 amp surface type ceiling rese including making connection testing etc. as required. (Group 2) | 167 | 45 | P.Cum |
168 | 168 | E071500 :- P & F ISI marked 6 amp Bakelite batten/ angle holder including making connection testing etc. as required. (Group 2) | 168 | 46 | P.Cum |
169 | 169 | E190103 : P & F strip type fluore scent tube fitting fabricated from (CRCA sheet and finished with powder coating/ stove enamelled paint)/ (extruded non corrosive UV resist EP channel) complete with accessories like (OCCB, starter, seat)/ EB, rotor holder, terminal block duly prewired with copper conductor including making connection, testing etc. as required (without tube) : 1 x 36 watts with EB. (Group 2). | 169 | 47 | P.Cum |
170 | 170 | E 200101 : P & F IP-43 protected street light luminaire on existing bracket suitable for FTL. Made out from CRCA sheet steel finished with stove enamelled paint, having deep drawn aluminium alloy canopy reflector cum control gear tray, clear ribbed acrylic diffuser held with synthetic gasket, with all necessary accessories copper wound ballast, capacitor, starter, holder prewired with pvc insulated copper conductor including making connection testing etc. as required. (without tube) : 1 X 36 watt GR 2. | 170 | 48 | P.Cum |
171 | 171 | E 190712 :- P & F fluorescent tube rod in existing fixtures as required : 36/ 40 watts. (Group 2) | 171 | 49 | P.Cum |
172 | 172 | E171001-P & F of heavy duty capacitor start,double ball bearing 900/1400 RPM single phase ISI marked exhaustfan ,IS : 2312 marked in existing opening including making connection teting etc. as required . 300 mm sweep (900/1400 RPM) GR-2 | 172 | 50 | P.Cum |
173 | 173 | E150100-Pipe Earthing as per IS:3043 with preforated 3.0Mtr. Long, 40 mm dai. 'B' class G.I. pipe including all accessories like nut, bolts, reducer, nipple,wire meshed funnel, and C.C. finished chember covered with hinged type with locking arrengement C.I. cover, C.I. frame of size 300 mm x 330 mm and embodeying the pipe comlete with alternate layers salt and coke/charcoal, testing of earth resistance as required. | 173 | 51 | P.Cum |
174 | 174 | E150703- S & Laying following size earth wire / strip in horizontal or vertical run in ground / surface /recess including riveting soldering , saddles, making connection etc. as requred. 8 SWG G.I. (Hot Dipped) wire. | 174 | 52 | P.Cum |
175 | 175 | E150802- S &Laying following size 'B' class G.I. pipe conferming to IS : 1239 P-1 (1990) with accessories for lating earth condector / strip/cable in ground/surface /recees as required. 20 mm dai. | 175 | 53 | P.Cum |
176 | 176 | S-2/2.2.1 : P&F GI pipes (external work)with GI fittings (IS:1239 Mark) includind trenching and refilling earth etc : 15 mm dia nominal bore | 176 | 54 | P.Cum |
177 | 177 | S-2/2.7.5: P&F bibcock (IS:8931 Mark) superior quality of approved make : CP Brass Long body 15 mm nominal bore weight not less than 690 gm. | 177 | 55 | P.Cum |
178 | 178 | S-2/2.13.3 : P & F 15 mm DIa connection pipe of approved quality/ make : PVC pipe with CP Brass nuts up to length 450 mm. | 178 | 56 | P.Cum |
179 | 179 | S-2/2.15 : P & F Full way Valve ( IS : 778 Mark) or wheel Valve of approved make. | 179 | 57 | P.Cum |
180 | 180 | (a). Gunmetal 15 mm nominal bore. | 180 | 58 | P.Cum |
181 | 181 | (b). Gunmetal 25 mm nominal bore. | 181 | 59 | P.Cum |
182 | 182 | S-2/2.26.2 : P & F PVC storage Tank (IS : 12701 marked indication the BIS license No.), of approved make with cover, 25 mm dia IM long GI over flowipe & 25 cm. Long wash out pipe with plug & socket, including making connection etc. complete of approved design : 300 litres capacity. | 182 | 60 | P.Cum |
183 | 183 | S-2/2.12.1 : P & F Inlet connection (Angle valves) Superior quality, of approved make for Washbasin, Gyset etc : CP Inlet connection 15 mm Brass (IS : 8931 marked) | 183 | 61 | P.Cum |
184 | 184 | S-3.20.-P & F rigid PVC pipe (IS:4985 mark) of approved quality /make including jointing of pipe with solvent cement rubber ring and lubricant. | 184 | 62 | P.Cum |
185 | 185 | (b)Bend 87.5 -110 mm dia | 185 | 63 | P.Cum |
186 | 186 | B-14.57.1 Dismantling roofs with care incluidng stacking of serviceable material and disposal of unserviceable material with in 50mtr. Lead for : (Lime terrace.) | 186 | 64 | P.Cum |
187 | 187 | B-15.17.2-Grading for roof water proofing treatment Cement concrete 1 : 2 : 4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) with watre proofing compound as per manufacture's specification | 187 | 65 | P.Cum |
188 | 188 | B-14.56.3 :- Dismantling of cement concrete flooring with care including stacking jof serviceable material with in 50 Mtr. Lead | 188 | 66 | P.Cum |
189 | 189 | B-12.48-Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repair to scratches by sandla/loi.(only for colour change) | 189 | 67 | P.Cum |
190 | 190 | B-10.8 Providing batta ( gola) 75mm X 75mm in cement concrete ( 1:2:4) including fineshing with cement mortar 1:3 as per standard design. | 190 | 68 | P.Cum |
191 | 191 | B-12.5-:Applying Birla/JK White cement based putty over cement plaster surface for making even surface | 191 | 69 | P.Cum |
192 | 192 | B-12/12.51.1:-Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: New work (two or more coats) over and including scrapping and priming coat with cement primer | 192 | 70 | P.Cum |
193 | 193 | B-7/ 7.7 : P & F vitrified porcelain polished (Naveen/ Euro make, size 600 mm x 600 mm and thickness 10 mm) on floor, skirting and steps etc. Laid wth tie admixture (Roff pidlite or equivalent) including filling of joints by water proofing tile grout (Fevimate, Roofie, Untile or equivalent) specially for adhesive with grade granuals, polymer and stable pigment fine finished including cleaning of joints etc. complete as per direction of Engineer Incharge. | 193 | 71 | P.Cum |
194 | 194 | B-11/11.57.1 : Providing and fixing of precast concrete interlocking blocks of M 30 grade 80 mm thick manufactured from fully computerised automatic stationery hydraulic vibropressed machine and fully computerised automatic batching plant of class A1/A2 as per BS 6717 : 2001. The CC interlocking paving blocks be laid on average 50 mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer in charge. The rates to be inclusive of all lead. Lifts and taxes General spectification of blocks . 1. Shape as defined by Engineer in charge. 2. Tensile splitting strength and braking load as per BS 6717 : 2001 . 3. Color Grey cement natural colour. 4. Variation in dimension Less than 1.6 mm. 5. Variation in thickness Less than 3.2 mm. 6. Abrasion As per BS : 6717 : 2001 | 194 | 72 | P.Cum |
195 | 195 | B-9/9.4.1- Structural steel work Welded in built up sections, trusses and framed work, including cutting , hoisting , fixinn in position and applyng a priming coat of approved steel primer all complete above plinth upto 4.5 mtr height. In flats , tees, angles and channels. | 195 | 73 | P.Cum |
196 | 196 | B-9/9.19.1 :- P&F steel gate grating and grills made of angles tees square bars or other flats black pipe with hold fasts and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide.Add extra if square,rectangular hollow tubelar sections are used | 196 | 74 | P.Cum |
197 | 197 | B-10/10.50.3-P & F Plain fiber glass sheet (FRP sheet fiber Reinforcement product steel confirming to IS-12866-1989 having minimum thickness as below including fixing with nuts ,bolts,hooks and bitumin washer etc. complete. 3.0 mm thick (wt 8.4 kg/mtr. sq) | 197 | 75 | P.Cum |
198 | 198 | 3.3.3 Providing and laying cement concrete including curing , compaction etc. complete in retaining walls ,walls (any thickness) including atteched pilasters, columnc ,piers, abutments,pillars,posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks,anchor blocks, plain window sills, fillets etc up to floor three level excluding the cost of centering and shuttering.1:2:4 (1 cement :2 coarse sand:a graded stone aggregate 20 mm nominal size) | 198 | 76 | P.Cum |
199 | 199 | B-1/1.8 :- Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms lift up to 1.5 mtr taking out the excavated soil and depositing & refilling of Jhiri with watering and ramming & disposal of surplus excavated soil as directed with in a lead of 50 Mtr. All kinds of soil. | 199 | 77 | P.Cum |
200 | 200 | B-10.1.1-Stone slabroofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both side in cement sand moratar 1:4 ,ralthal,stone kharanja,lime terracing 90 mm average thickness (as per jaipur practice)with ceiling pointing in cement sand mortar 1:3 complete as per specification for span up to 2.0 mtr | 200 | 78 | P.Cum |
201 | 201 | B-14.57.2 :- Dismantling roofs with care including stacking of serviceable material and disposal of universable material with in 50 mtr. Lead for : | 201 | 79 | P.Cum |
202 | 202 | Note:\n1. Banas Sand/ Sota Nallha washed sand / Roopangarh sand / Massi sand will be permitted after proper quality test from RRVPNL lab.\n2. Water shall be provided free of cost if available at site at one point nearer to the water source.\n3. Cube moulds and testing of mortar as well as for concrete arranged by the contractor at site at his own cost for proper quality measures by the department. All the cubes shall be transported on time by the contractor upto Sub Div. Office Bharatpur at his own cost.\n4. Prior to the start of the work sand, bricks and aggregate shall be dually tested and samples shall be arranged by the contractor in presence of JEN/AEN upto the Sub Div. office Bharatpur. | 202 | 13 | P.Cum |
203 | 203 | Part- A : Building work | 203 | 14 | P.Cum |
204 | 204 | B-3/3.2.7:-Providing and laying in position cement concrete including curing. Compaction etc. Complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size.) | 204 | 15 | P.Cum |
205 | 205 | B-3/3.2.2 :- Providing and laying in position cement concrete including curing. Compaction etc. Complete in specified grade excluding the cost of centering and shuttering - All work up toplinth level M-20 grade nominal mix (with graded stone aggregate 20 mm nominal size) | 205 | 16 | P.Cum |
206 | 206 | B-5/5.17:-Brick masonry in super structure upto third storey with bricks of class designation 75 in cement mortar 1:6(1 cement:6 coarse sand | 206 | 17 | P.Cum |
207 | 207 | B-14.54 Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50meter lead | 207 | 18 | P.Cum |
208 | 208 | B-12/12.9.2&3 :- Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished | 208 | 19 | P.Cum |
209 | 209 | a -20 mm thick | 209 | 20 | P.Cum |
210 | 210 | B-5.8.4.+5.9 : Half brick masonary in super structure using bricks of designation 75. Cement mortar 1 : 6 ( 1 cement : 6 Coarse sand). | 210 | 21 | P.Cum |
211 | 211 | B-6/ 6.16.4 : Supplying and fixing in walls machine cut and polished stone shelves, tands and sills in CM 1 : 3 with machine cut edges. Kota stone 25 to 30 mm thick. | 211 | 22 | P.Cum |
212 | 212 | B-12/12.44.2 : White washing with lime to give an even shade including all scaffolding : Old work (two or more coats)including scrapping old surface and repairing with whiting whereever necessary | 212 | 23 | P.Cum |
213 | 213 | B-12/12.47.1 :- Color washing of all shades to give an even shade including all scaffolding : New work (two or more coats) with a coat of white washing with lime. | 213 | 24 | P.Cum |
214 | 214 | B-12/12.53.1 :- Finishing wall with water proofing cement paint or approved brand and manufacture and or required shade to give and even shade to give all scaffolding : New work (Three or more coats). | 214 | 25 | P.Cum |
215 | 215 | B-12/12.68.1 :- Painting with enamel paint of approved brand and manufacture to give and even shade : Two or more coats on new work. | 215 | 26 | P.Cum |
216 | 216 | B-12/12.68.1 :- Painting with enamel paint of approved brand and manufacture to give and even shade : One or more coats on old work. | 216 | 27 | P.Cum |
217 | 217 | S/3.19.3 : P & F rigid PVC pipe (IS : 4985 mark) class II (4 KG./cm 2) approved quality/ make including joining the pipe with solvent cement rubber ring and lubricant : | 217 | 28 | P.Cum |
218 | 218 | (b) 110 mm dia. | 218 | 29 | P.Cum |
219 | 219 | E020100 :- Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sq. Mm FR PVC insulated unsheathed flexible copper earth conductor 1.1 KV grade (IS : 694) of approved make in surface/ recessed ISI marked medium duty PVC conduit & it’s accessories, round tiles, 18 SWG MS box with earth terminal, screwless cage connectors for netural looping in switch. 3.0 mm thick phenolic laminated sheet, zinc plated/ brass screws, cup washers, making connections, testing etc, as required (Group 2) | 219 | 30 | P.Cum |
220 | 220 | (a) E020101 : Short point (up to 3 Mtr.) | 220 | 31 | P.Cum |
221 | 221 | (b) E020102 : Medium point (up to 6 Mtr.) | 221 | 32 | P.Cum |
222 | 222 | (c) E020103 : Long point (up to 10 Mtr.) | 222 | 33 | P.Cum |
223 | 223 | E020301 :- Wiring of 3 pin 5 amp. Light plug point with 1.5 sq. Mm FR PVC insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq mm FR PVC insulated unsheathed flexible copper earth conductor 1.1 kv grade (IS : 694) of approved make in surface/ recessed ISI marked medium duty PVC conduit & it’s accessories, round tiles 18 SWG MS box with earth terminal, screwless cage connectors for netural looping in switch board & falce ceiling point, 6 A switch 6 A scoket. 3.0 mm thick phenolic laminated sheet, zinc plated/ brass screws, cup washers, making connections, testing etc, as required on board. (Group 2) | 223 | 34 | P.Cum |
224 | 224 | E040100 :- Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS : 694) of 11 kv grade and approved make in existing surface or recessed conduit/ casing capping including making conne-ctions etc. as required (Group 1) | 224 | 35 | P.Cum |
225 | 225 | (a) E040108 : 2 X 2.5 sq.mm + 1.5 sq. mm | 225 | 36 | P.Cum |
226 | 226 | (b) E040117 : 2 X 4.0 sq. mm +2.5 sq. mm | 226 | 37 | P.Cum |
227 | 227 | E 072200-P/F ISI marked flush type 120/280 watt rotary step fan regulator i/c makin connection testin etc. as required Gr-2 | 227 | 38 | P.Cum |
228 | 228 | E071000-P&F ISI marked (IS:1293) 3 pin 6 amp. Porcelain base tumbler socket including making connection testing etc. as required (Gr.2) | 228 | 39 | P.Cum |
229 | 229 | E070300-P&F ISI marked (IS 3854) 6A flush type switch including cutting hole in tile and making connection testing etc. as required. Group-2 | 229 | 40 | P.Cum |
230 | 230 | E04000 :- Supplying and fixing of power plug point accessories on 18 SWG metal box of size 175 X 100 X 60 mm on surface or in recessed with suitable size phenolic laminated sheet cover including cost of 6 pin 16 amp. Switch and socket outlet, making connection, testing etc. as required (Group 2). | 230 | 41 | P.Cum |
231 | 231 | E060112 :- P & F 240/415 V MCB of breaking capacity not less than 10 KA (B/C/D tripping characteristic) ISI marked IS 8828 (1996)/ conforming to IEC 60898 in existing board/ sheets including making connections with lugs, testing etc. as required : 6 A to 32 A rating (Group 2) | 231 | 42 | P.Cum |
232 | 232 | E060211 : P & F 240/415 V isolator conforming to IS : 13947 – III/ IEC 60947-3 on existing board/ sheet including making connections with lugs. Testing etc. As required : 30 A/ 40 A rating. (Group 2). | 232 | 43 | P.Cum |
233 | 233 | E060512 :- P & F recessed/ surface mounting heavy duty horizontal type sheet steel distribution board phophatised/powder painted complete with copper bus bas, shorting ling, neutral link, earth link and din bar, conforming to IS 13032 & IS 8623 including making internal DB terminations with copper lugs, testing etc, as required : 6 way (Group 2) | 233 | 44 | P.Cum |
234 | 234 | E071400 : P & F IS : 371 marked 6 amp surface type ceiling rese including making connection testing etc. as required. (Group 2) | 234 | 45 | P.Cum |
235 | 235 | E071500 :- P & F ISI marked 6 amp Bakelite batten/ angle holder including making connection testing etc. as required. (Group 2) | 235 | 46 | P.Cum |
236 | 236 | E190103 : P & F strip type fluore scent tube fitting fabricated from (CRCA sheet and finished with powder coating/ stove enamelled paint)/ (extruded non corrosive UV resist EP channel) complete with accessories like (OCCB, starter, seat)/ EB, rotor holder, terminal block duly prewired with copper conductor including making connection, testing etc. as required (without tube) : 1 x 36 watts with EB. (Group 2). | 236 | 47 | P.Cum |
237 | 237 | E 200101 : P & F IP-43 protected street light luminaire on existing bracket suitable for FTL. Made out from CRCA sheet steel finished with stove enamelled paint, having deep drawn aluminium alloy canopy reflector cum control gear tray, clear ribbed acrylic diffuser held with synthetic gasket, with all necessary accessories copper wound ballast, capacitor, starter, holder prewired with pvc insulated copper conductor including making connection testing etc. as required. (without tube) : 1 X 36 watt GR 2. | 237 | 48 | P.Cum |
238 | 238 | E 190712 :- P & F fluorescent tube rod in existing fixtures as required : 36/ 40 watts. (Group 2) | 238 | 49 | P.Cum |
239 | 239 | E171001-P & F of heavy duty capacitor start,double ball bearing 900/1400 RPM single phase ISI marked exhaustfan ,IS : 2312 marked in existing opening including making connection teting etc. as required . 300 mm sweep (900/1400 RPM) GR-2 | 239 | 50 | P.Cum |
240 | 240 | E150100-Pipe Earthing as per IS:3043 with preforated 3.0Mtr. Long, 40 mm dai. 'B' class G.I. pipe including all accessories like nut, bolts, reducer, nipple,wire meshed funnel, and C.C. finished chember covered with hinged type with locking arrengement C.I. cover, C.I. frame of size 300 mm x 330 mm and embodeying the pipe comlete with alternate layers salt and coke/charcoal, testing of earth resistance as required. | 240 | 51 | P.Cum |
241 | 241 | E150703- S & Laying following size earth wire / strip in horizontal or vertical run in ground / surface /recess including riveting soldering , saddles, making connection etc. as requred. 8 SWG G.I. (Hot Dipped) wire. | 241 | 52 | P.Cum |
242 | 242 | E150802- S &Laying following size 'B' class G.I. pipe conferming to IS : 1239 P-1 (1990) with accessories for lating earth condector / strip/cable in ground/surface /recees as required. 20 mm dai. | 242 | 53 | P.Cum |
243 | 243 | S-2/2.2.1 : P&F GI pipes (external work)with GI fittings (IS:1239 Mark) includind trenching and refilling earth etc : 15 mm dia nominal bore | 243 | 54 | P.Cum |
244 | 244 | S-2/2.7.5: P&F bibcock (IS:8931 Mark) superior quality of approved make : CP Brass Long body 15 mm nominal bore weight not less than 690 gm. | 244 | 55 | P.Cum |
245 | 245 | S-2/2.13.3 : P & F 15 mm DIa connection pipe of approved quality/ make : PVC pipe with CP Brass nuts up to length 450 mm. | 245 | 56 | P.Cum |
246 | 246 | S-2/2.15 : P & F Full way Valve ( IS : 778 Mark) or wheel Valve of approved make. | 246 | 57 | P.Cum |
247 | 247 | (a). Gunmetal 15 mm nominal bore. | 247 | 58 | P.Cum |
248 | 248 | (b). Gunmetal 25 mm nominal bore. | 248 | 59 | P.Cum |
249 | 249 | S-2/2.26.2 : P & F PVC storage Tank (IS : 12701 marked indication the BIS license No.), of approved make with cover, 25 mm dia IM long GI over flowipe & 25 cm. Long wash out pipe with plug & socket, including making connection etc. complete of approved design : 300 litres capacity. | 249 | 60 | P.Cum |
250 | 250 | S-2/2.12.1 : P & F Inlet connection (Angle valves) Superior quality, of approved make for Washbasin, Gyset etc : CP Inlet connection 15 mm Brass (IS : 8931 marked) | 250 | 61 | P.Cum |
251 | 251 | S-3.20.-P & F rigid PVC pipe (IS:4985 mark) of approved quality /make including jointing of pipe with solvent cement rubber ring and lubricant. | 251 | 62 | P.Cum |
252 | 252 | (b)Bend 87.5 -110 mm dia | 252 | 63 | P.Cum |
253 | 253 | B-14.57.1 Dismantling roofs with care incluidng stacking of serviceable material and disposal of unserviceable material with in 50mtr. Lead for : (Lime terrace.) | 253 | 64 | P.Cum |
254 | 254 | B-15.17.2-Grading for roof water proofing treatment Cement concrete 1 : 2 : 4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) with watre proofing compound as per manufacture's specification | 254 | 65 | P.Cum |
255 | 255 | B-14.56.3 :- Dismantling of cement concrete flooring with care including stacking jof serviceable material with in 50 Mtr. Lead | 255 | 66 | P.Cum |
256 | 256 | B-12.48-Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repair to scratches by sandla/loi.(only for colour change) | 256 | 67 | P.Cum |
257 | 257 | B-10.8 Providing batta ( gola) 75mm X 75mm in cement concrete ( 1:2:4) including fineshing with cement mortar 1:3 as per standard design. | 257 | 68 | P.Cum |
258 | 258 | B-12.5-:Applying Birla/JK White cement based putty over cement plaster surface for making even surface | 258 | 69 | P.Cum |
259 | 259 | B-12/12.51.1:-Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: New work (two or more coats) over and including scrapping and priming coat with cement primer | 259 | 70 | P.Cum |
260 | 260 | B-7/ 7.7 : P & F vitrified porcelain polished (Naveen/ Euro make, size 600 mm x 600 mm and thickness 10 mm) on floor, skirting and steps etc. Laid wth tie admixture (Roff pidlite or equivalent) including filling of joints by water proofing tile grout (Fevimate, Roofie, Untile or equivalent) specially for adhesive with grade granuals, polymer and stable pigment fine finished including cleaning of joints etc. complete as per direction of Engineer Incharge. | 260 | 71 | P.Cum |
261 | 261 | B-11/11.57.1 : Providing and fixing of precast concrete interlocking blocks of M 30 grade 80 mm thick manufactured from fully computerised automatic stationery hydraulic vibropressed machine and fully computerised automatic batching plant of class A1/A2 as per BS 6717 : 2001. The CC interlocking paving blocks be laid on average 50 mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer in charge. The rates to be inclusive of all lead. Lifts and taxes General spectification of blocks . 1. Shape as defined by Engineer in charge. 2. Tensile splitting strength and braking load as per BS 6717 : 2001 . 3. Color Grey cement natural colour. 4. Variation in dimension Less than 1.6 mm. 5. Variation in thickness Less than 3.2 mm. 6. Abrasion As per BS : 6717 : 2001 | 261 | 72 | P.Cum |
262 | 262 | B-9/9.4.1- Structural steel work Welded in built up sections, trusses and framed work, including cutting , hoisting , fixinn in position and applyng a priming coat of approved steel primer all complete above plinth upto 4.5 mtr height. In flats , tees, angles and channels. | 262 | 73 | P.Cum |
263 | 263 | B-9/9.19.1 :- P&F steel gate grating and grills made of angles tees square bars or other flats black pipe with hold fasts and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide.Add extra if square,rectangular hollow tubelar sections are used | 263 | 74 | P.Cum |
264 | 264 | B-10/10.50.3-P & F Plain fiber glass sheet (FRP sheet fiber Reinforcement product steel confirming to IS-12866-1989 having minimum thickness as below including fixing with nuts ,bolts,hooks and bitumin washer etc. complete. 3.0 mm thick (wt 8.4 kg/mtr. sq) | 264 | 75 | P.Cum |
265 | 265 | 3.3.3 Providing and laying cement concrete including curing , compaction etc. complete in retaining walls ,walls (any thickness) including atteched pilasters, columnc ,piers, abutments,pillars,posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks,anchor blocks, plain window sills, fillets etc up to floor three level excluding the cost of centering and shuttering.1:2:4 (1 cement :2 coarse sand:a graded stone aggregate 20 mm nominal size) | 265 | 76 | P.Cum |
266 | 266 | B-1/1.8 :- Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms lift up to 1.5 mtr taking out the excavated soil and depositing & refilling of Jhiri with watering and ramming & disposal of surplus excavated soil as directed with in a lead of 50 Mtr. All kinds of soil. | 266 | 77 | P.Cum |
267 | 267 | B-10.1.1-Stone slabroofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both side in cement sand moratar 1:4 ,ralthal,stone kharanja,lime terracing 90 mm average thickness (as per jaipur practice)with ceiling pointing in cement sand mortar 1:3 complete as per specification for span up to 2.0 mtr | 267 | 78 | P.Cum |
268 | 268 | B-14.57.2 :- Dismantling roofs with care including stacking of serviceable material and disposal of universable material with in 50 mtr. Lead for : | 268 | 79 | P.Cum |
269 | 269 | Stone slab roofing complete with lime dhar and kharanja. | 269 | 80 | P.Cum |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy