| 1 | 1 | SCHEDULE \"A\" Part - I (BUILDING WORKS)\nDetails of prepriced schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 2 | 2 | SCHEDULE \"A\" PART-II ( EARTH WORK AND SITE CLEARENCE) \nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 3 | 3 | SCHEDULE \"A\" PART-III (INTERNAL WATER SUPPLY)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 4 | 4 | SCHEDULE \"A\" PART-IV (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 5 | 5 | SCHEDULE \"A\" PART-V (ROAD/PATH/CULVERT)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 6 | 6 | SCHEDULE \"A\" PART-VI (SEWAGE DISPOSAL)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 7 | 7 | SCHEDULE \"A\" PART-VII (AREA DRAINAGE)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 8 | 8 | SCHEDULE \"A\" PART-VIII (EXTERNAL WATER SUPPLY)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 9 | 9 | SCHEDULE \"A\" PART-IX (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 10 | 10 | SCHEDULE \"A\" PART-X (REFRIGERATION AND AIR CONDITION)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 11 | 11 | SCHEDULE \"A\" PART-XI (HOT WATER SUPPLY)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 12 | 12 | SCHEDULE \"A\" PART -XII (MISCELLANIOUS ITEMS) Note:- \nThis schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under Col.' E ' signifies this fact only. | | | |
|---|
| 13 | 12.01 | INTERNAL WATER SUPPLY\nS & F Two way bib tap 15 mm complete all as specified. Make – Drizzel & Prayag or equivalent | | 11 | Each |
|---|
| 14 | 12.02 | SUPPLY AND FIXING ANGLE COCK, 15MM FANCY TYPE,\nCHROMIUM PLATED, SCREWED DOWN, HIGH\nPRESSURE, WITH SCREWED BOTH ENDS\nFOR IRON PIPE OR FOR UNIONS AND FIXED\nCOMPLETE ALL AS SPECIFIED AND AS DIRECTED.\nMAKE : PRAYAG (CAT PAT NO-8510) OR I\nEQUIVALENT AS APPROVED BY GE. | | 35 | Each |
|---|
| 15 | 12.03 | SUPPLY AND FIXING 15MM DIA BIB TAPS LONG BODY\nWITH FLANGE CHROMIUM PLATED CAST\nCOPPER ALLOY WITH COMPLETE ALL AS\nSPECIFIED AND DIRECTED.\nMAKE : PRAYAG (CAT PAT NO-8608) OR EQUIVALENT\n AS APPROVED BY GE. | | 7 | Each |
|---|
| 16 | 12.04 | SUPPLY AND FIXING 7\" OVER HEAD SHOWER WITH\n225MM WITH FLANGE COMPLETE ALL AS SPECIFIED.\nMAKE : PRAYAG (CAT PAT NO BS-78) OR EQUIVALENT\n AS APPROVED BY GE. | | 5 | Each |
|---|
| 17 | 12.05 | SUPPLY & FIXING STOP VALVE (CONCEALED TYPE)\n15 MM BORE CAST COPPER ALLOY FANCY TYPE,\nCHROMIUM PLATED WITH LONG SHANK AND CUP,\nHIGH PRESSURE, WITH SCREWED BOTH ENDS FOR\nIRON PIPE OR FOR UNIONS\nMAKE : PRAYAG (CAT PAT NO-8518) OR EQUIVALENT\n AS APPROVED BY GE. | | 5 | Each |
|---|
| 18 | 12.06 | INTERNAL ELECTRIC SUPPLY\nS & F modular type 1 module TV socket complete all as specified and directed. Make: Legrand Arteor Cat-Part No. 5734 25 or equivalent model of ABB / Hager / Wipro / L&T | | 1 | Each |
|---|
| 19 | 12.07 | S&F DB VTPN, 4Way, Double Door, IP43 protection with connected accessories like insulated bus bars, insulated IP2X neutral bars and earth Bars, blanking plates, cable management kit, incoming as MCCB and outgoing SP/TP MCB all as specified and directed. | | 1 | Each |
|---|
| 20 | 12.08 | S & F 20 W surface/wall mounted LED batten having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed.\nMake: BAJAJ Cat-Part No. 112785 BCLAB 20W or equivalent model of Havells, Philips or Wipro | | 115 | Each |
|---|
| 21 | 12.09 | S&F 10W surface/ wall mounted LED batten light having high efficiency long light LED chips with luminious efficiency of >100lumen/W, Independent isolated SMPS based constant current electronic LED driver with TSD<20%, Surge voltage protection and other safety test as per IS:15885(part 2/ sec 13:2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220V-240VC, input Frequency 50-60Hz, PF>0.945, including electrical connection with 2 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. Make:Bajaj cat part No: 112785 BCLAB 20W or Equivalent model of Phillips/Havells/ Wipro. | | 12 | Each |
|---|
| 22 | 12.1 | S&F LED street light 25W, lumen output not less than 2500 lumens high pressure die cast aluminium housing 140/270V, 50Hz, PF>0.90, including 1.2Mtr long 40/50mm bore light grade GI pipe mounting bracket made to shape with and including MS clamp of FI 40mmX6mm with bolts,nuts,washers and conductors to fitting with 3 core 1sqmm PVC insulated copper cable from control box to fitting complete all as specified.NOTE:The quoted unit rate deemed include for painting to clamps with one coat of red oxide paint before fixing. Complete all as specified and directed by Engineer-in-Charge.Make:-Wipro Cat No: LR02-291-xxx-57xx/GE Cat No: PALM-MIN or equivalent in Phillips | | 7 | Each |
|---|
| 23 | 12.11 | S & F BEE five star rated energy efficient high-speed ceiling fan having 1200 mm blade sweep, air-flow not less than 210 CMM, operating voltage 220-240 V and frequency 50 Hz, including a downroad of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan complete all as specified and directed. \nMake: Crompton Cat-Part No. ENTRUST50 or Havells Cat- Part No. ES-50 or equivalent model of Usha or BAJAJ. | | 40 | Each |
|---|
| 24 | 12.12 | S & F engery efficient metalic exhaust fan having blade sweep 300 mm, air delivery upto 1600 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. \nMake: Crompton Cat-Part No. TRANS AIR 12\" or equivalent model of Usha, Havells or BAJAJ | | 2 | Each |
|---|
| 25 | 12.13 | S & F engery efficient non-metalic fresh air fan having blade sweep 250 mm, air delivery upto 900 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. \nMake: Crompton Cat-Part No. VENTILUS 10\" or equivalent model of Usha, Havells or BAJAJ | | 11 | Each |
|---|
| 26 | 12.14 | S & F ISI marked MCB for AC applications till 63 A, having breaking capacity Icn = 10 kA, conforming to IS/IEC 60898-1-2002, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters, all complete as specified and directed. \nMake: Schneider, Legrand, Havells. | | | |
|---|
| 27 | 12.15 | 6 A, SP MCB, C- curve | | 32 | Each |
|---|
| 28 | 12.16 | 16 A, SP MCB, C- curve | | 10 | Each |
|---|
| 29 | 12.17 | 20 A, SP MCB, C- curve | | 1 | Each |
|---|
| 30 | 12.18 | 32 A, DP MCB, C- curve | | 4 | Each |
|---|
| 31 | 12.19 | S & F MCCB of 63 A, 25 kA, 04 pole all as specified and directed | | 1 | Each |
|---|
| 32 | 12.2 | M&L for earthing complete with galvanized steel earth plate electrode including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60cmX60cmX6mm thick buried directly in ground(Earth pit not less than 2.25m below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanized earth strip 25X 4mm as earth lead by means of bolt nuts, check nuts and washers of galvanized iron or steel all as shown in electric plate no.3 of MES SSR PART I connected to main switch board or main control board all as specified and testing on completion including provision of earth strip protected by galvanized iron 40mm dia. Light grade pipe and watering pipe shall be 20mm bore medium grade PCC pit with pre cast RCC cover,charcoal/salt funnel etc. complete all as directed\nNOTE:1) The concrete pit shall be PCC 1:3:6 tye C-140-40mm thick pre-cast cover slab of RCC(1:2:4) type B-1 using 20mm graded stone aggregate enforced with 8mm TMT bar@ 10cm C/C on both sides with suitable casts iron handle shall be provided in lieu of cast iron cover shown in electrical plate no. 3 of MES SSR PART I \n2) Item includes the cost of 7.5m GI pipe for protection of earth strip.\n3) PCC pit shall be provided atleast 500mm away from the pit and not on the earth pit itself and extra cost of additional length of watering pipe, bends, elbows etc. shall be deemed to be included in the quote rate.\n4) Item includes the cost of 7.5m length of earth strip.\n | | 2 | Each |
|---|
| 33 | 12.21 | EXTERNAL ELECTRIFICATION\nSupply and lay double corrugated (DWC) High density polythene pipes having corrugation on the outer wall and plain surface on the inner wall, size 63mm outer dia for protection of UG Cable, with all fittings, laid in trenches/roads/ drain or fixed along wall/poles or laid under PCC interlocking tiles including road cutting and making good, complete all as specified and directed.\nMAKE: REX/POLY/ Gemini or equivalent. | | 80 | Rm |
|---|
| 34 | 12.22 | M & L for earthing complete with galvanized steel earth pipe electrode of 40mm bore, medium grade, 2.5 metre length buried directly and preferably in ground with top edge not less than 1.25 metres below ground level connected with 25x4mm GI strip galvanised iron or steel wire all as shown in plate no 2 to the earthing test point all as specified and indicated including testing on completion all as specified & directed.\nNote : Cost of earth lead 4mm dia & GI pipe for protection of earth strip deemed to be included in unit rate up to 7.5 meter | | 2 | Each |
|---|
| 35 | 12.23 | REFRIGERATION AND AIR CONDITION\nSupply and fix voltage stabilizing for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 140V to 280V, with output voltage stabilized at 230 Volt with accuracy of +/- 10% and of capacity 1.0 KVA.\nMake: V-Guard/Volina/AE/ Aplab.\n | | 4 | Each |
|---|
| 36 | 12.24 | Supply, Installation, commisioning of refrigerator, electric driven single phase having capacity upto 260 Lrs 3star rated Frost Free, Double door complete all as specified and directed.\nMake: LG/ Whirlpool/Samsung\n | | 1 | Each |
|---|
| 37 | 12.25 | HOT WATER SUPPLY\nSOLAR WATER HEATER\nSupply, installation & testing Solar Water heating system of cap 200 LPD consisting of flat plate collector box fabricated from aluminium extruded sections by means of gas welding or brazing leak proof fully insulated with glass wool (48Kg/M3) with supporting structure duly painted with synthetic enamel black paint over a coat of zinc chromate red oxide primer provided with absorber made from copper sheet & copper tubes with protective coating complete with header grommet, storage tank made from stainless steel sheet of minimum 20 SWG thickness with puff insulation of minimum 50 mm girth outer including of brass socket & nipple fully insulated with glass wool with cold & hot water piping, gun metal valves, coil type stainless steel heat exchanger complete conforming to IS-12933 & 12976 with necessary wiring fixed on PCC platform, cold water tank & make up water tank capacity 200 Litresper day capable to supply hot water at 60°C all as specified and directed \nMake :- SINTEX/BHEL/TATA /BP SOLAR INDIA LIMITED/Honey well/Bosch/Racold\nNotes:\n(i) The system will be provided with electric back up 2KW for 100 litre capacity solar water heating system.\n(ii) The hot water pipe shall be 20mm KITEC (PE-AL-PE) and its cost up to 5.00 RM shall be deemed to be included in rates quoted against respective item.\n(iii) The thickness of stainless steel sheet of storage tank will be 20 gauge. | | 1 | Each |
|---|