| 1 | 1 | SCHEDULE \"A\" Part - I (BUILDING WORKS)\nDetails of prepriced schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 2 | 2 | SCHEDULE \"A\" PART-II ( EARTH WORK AND SITE CLEARENCE) \nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 3 | 3 | SCHEDULE \"A\" PART-III (INTERNAL WATER SUPPLY)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 4 | 4 | SCHEDULE \"A\" PART-IV (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 5 | 5 | SCHEDULE \"A\" PART-V (ROAD/PATH/CULVERT)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 6 | 6 | SCHEDULE \"A\" PART-VI (SEWAGE DISPOSAL)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 7 | 7 | SCHEDULE \"A\" PART-VII (AREA DRAINAGE)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 8 | 8 | SCHEDULE \"A\" PART-VIII (EXTERNAL WATER SUPPLY)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 9 | 9 | SCHEDULE \"A\" PART-IX (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 10 | 10 | SCHEDULE \"A\" PART-X SOLAR WATER SUPPLY)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 11 | 11 | SCHEDULE \"A\" PART-XI \n(CONDUIT FOR TELEPHONE)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 12 | 12 | SCHEDULE \"A\" PART-XII \n(REFRIGERATION AND AIR CONDITION)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 13 | 13 | SCHEDULE \"A\" PART -XIII (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under Col.' E ' signifies this fact only. | | | |
|---|
| 14 | 13.01 | INTERNAL WATER SUPPLY\n | | | |
|---|
| 15 | 13.02 | S&F Angular stop cock 15 mm dia, quarter turn Make - Jaquar Model No CQT-23053 or equivalent in Crab Tree/Kohler brand. | | 14 | Each |
|---|
| 16 | 13.03 | S&F Sink cock with swinging casted round shape spout (Wall mounted model) 20 mm dia, quarter turn Make - Jaquar Model No CQT-23347 or equivalent in Crab Tree/Kohler brand. | | 16 | Each |
|---|
| 17 | 13.04 | S&F two way bib cock 15 mm dia. Make - Jaquar Model No CQT-23041 or equivalent in Crab Tree/Kohler brand. | | 8 | Each |
|---|
| 18 | 13.05 | INTERNAL ELECTRIC SUPPLY\nS & F 20 W surface/wall mounted LED batten, operating voltage 140- 270, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the LED batten fitting complete all as specified and directed. Make :- Bajaj BLTRU 20 W WH VIVA / Philips BN108C- LED- 20 S-6500 / OSRAM LUXPOWER BATTEN 19WL 840\n | | 141 | Each |
|---|
| 19 | 13.06 | S & F Recessed mounted LED luminare made of pressure diecast aluminium of 32/36 Watt (Nominal)operating voltage 140- 270, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the LED batten fitting complete all as specified and directed. Make :- Bajaj BXTAR 40W LED W / WIPRO-LD-56 / OSRAM | | 22 | Each |
|---|
| 20 | 13.07 | S & F 10 W surface/wall mounted LED batten tubelight, including LED tube/module, with PC diffuser and extruded aluminium anodised housing with LEDs as light source having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.98, CCT 6500K, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the LED batten fitting complete all as specified and directed. [Make: BAJAJ 112407 BCLSB 10 WH or equivalent] | | 60 | Each |
|---|
| 21 | 13.08 | S & F 20 W LED security light having pressure die-cast housing with toughned glass and individual LEDs with secondary optics and IP 65 protection, including necessary electrical connections to security light fittings with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete all as specified and directed. [Make:BAJAJ BCLST 20W LED I /PHILIPS BRP 022 /WIPRO(Skyline) | | 8 | Each |
|---|
| 22 | 13.09 | S & F BEE five star rated high-speed ceiling fan, conforming to IS 374- 1979, having 1200 mm blade sweep, speed not less than 370 RPM, air-flow not less than 210 CMM, operating voltage 220-240 V and frequency 50 Hz, including a downroad of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan complete all as specified and directed. [Make: CROMPTON EMPOWER 50/ USHA (ENERGIA 32) / Havells ES-50 Premium) | | 56 | Each |
|---|
| 23 | 13.1 | S & F engery efficient non-metalic fresh air fan having blade sweep 250 mm, speed not greater than 900 RPM, air delivery not less than 800 Cum/hr, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. [Make: CROMPTON VENTILUS /USHA (CrispAir) / ORIENT (VENTILATOR DX) | | 7 | Each |
|---|
| 24 | 13.11 | S & F ISI marked MCB having breaking capacity Icn = 10 kA, conforming to IS/IEC 60898-1-2002 complete all as specified and directed. [Make: Legrand /Hager / Schneider / Siemens) | | | |
|---|
| 25 | 13.12 | 6 A, 230 V, 50 Hz SP MCB C- curve | | 68 | Each |
|---|
| 26 | 13.13 | 16 A, 230 V, 50 Hz SP MCB C- curve | | 21 | Each |
|---|
| 27 | 13.14 | 20 A, 230 V, 50 Hz SP MCB C- curve | | 10 | Each |
|---|
| 28 | 13.15 | 40 A, 230 V, 50 Hz SPN MCB C- curve | | 1 | Each |
|---|
| 29 | 13.16 | 40 A,415 V, 50 Hz FP MCB C- curve | | 1 | Each |
|---|
| 30 | 13.17 | 63 A,415 V, 50 Hz FP MCB C- curve | | 1 | Each |
|---|
| 31 | 13.18 | S & F VTPN DB MADE OF 1.6 MM THICK CRCA SHEET, FOR FLUSH MOUNTING TYPE WITH 200 AMP BUSBAR COPPER, FULLY INSULATED & SHROUDED NEUTRAL BAR, EARTH BAR, IN BAR, SUITABLE FOR FP MCCB 160 A AND OUTGOING MCB SP/TP ALL AS SPECIFIED AND COMPRISING OF FOLLOWING:-\n(i) MCCB FP 160 A, 25 KA, 415 V. - 01 NOS\n(ii) MCB SP 32 A, 10 KA - 06 NOS\n(iii) MCB TP 63 A, 10 KA - 02 NOS\nMAKE: SCHNEIDER/ L&T/HAGER | | 1 | Each |
|---|
| 32 | 13.19 | S & F LONG RANGE INTEGRATED CT METER FOR 40 A – 200 A, 3 PHASE, WITH OPTICAL PORT, TAMPER PROOF, INCLUDING TRANSPARENT PILFER PROOF METER BOX ALL AS SPECIFIED AND DIRECTED.\nMAKE: HPL/ L&T/SECURE | | 1 | Each |
|---|
| 33 | 13.2 | SEWAGE DISPOSAL\nS&F for sintex Advance septic tank (PWTS-AM Model) of capacity of 1.6 KL all as spd and Directed by Engr in charge. | | 1 | Each |
|---|
| 34 | 13.21 | Soakage well exc, in ordinary soil,filled with bats, and PCC plaster on top for 1.8 M dia X 3.0 M effective depth soakage pit | | 2 | Each |
|---|
| 35 | 13.22 | EXTERNAL ELECTRIFICATION\nMaterial and Labour for Earthing complete with galvanised steel earth electrode 60 cm x 60 cm x 6 mm as earthing lead burried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to galvanised iron strip 32×6mm as earthing lead by means of bolts,nuts, check nuts and washer etc made of galvanised iron including 40 mm bore GI pipe medium grade up to 7.5 metres long all as shown in electrcial plate No.3 of SSR Part I 2009 and as specified or indicated and testing on completion including excavation/ earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 20 mm bore medium grade GI watering pipe, lugs, 40 mm bore medium grade GI protection pipe, test point etc. complete all as specified and as directed by Engr-in-charge. Note: (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. Any aditional in length shall be adjusted through deviation order. (ii) Item includes trhe cost of 7.5 metre GI earth lead. Any additional in length shall be measured and paid under respective item of this Schdule. | | 6 | Each |
|---|
| 36 | 13.23 | M & L for LT panel Board cubical Indoor type, wall mounted compact 415 Volts AC 50 Hz, 4 wire +E, fabricated Polycarbonate, Nominal Size 990 mmX 950mmX 321mm, RAL 7035 finish confirming to IP 54 complete including terminal block 10 Sqmm, bottom cable entry comprising of following.\n(a) Incoming MCCB 63 Amps four pole with Microprocessor based release having breaking capacity 16KA, ---01 No.\n(b) Outgoing MCB 63 Amps DP, 16KA….4Nos \n(c) Indicating lamps set RYB - 01 set \n(d) Energy meter, AC single phase of accuracy class 1.0, 240 V, 50 Hz with Backlit LCD display of rating 5 - 30 A, (measures and displays KWH ,V, Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, temper logging, optical communication port display in absence of power with transparent hinge type box-4Nos\nMake :- Panel: Hensal / Hager / universal swithgear / neptune METER : HPL / SECURE / L&T | | 3 | Each |
|---|
| 37 | 13.24 | Supply and fix octagonal hot-dip galvanized street light poles including junction box, height 7 mtrs, top dia 70mm, bottom dia 130 mm, sheet thickness 3 mm, base plate 220x220x12,foundation nut bolts as per manufacturer recommendation including reinforced cement concrete foundation and hot dip galvanised bracket single arm for fixing of street light and one no of MCB 6 amp including 25 Amp four way terminal block all as spd and directed. MAKE: BAJAJ/SURYA/PHILIPS/UTKARSH | | 6 | Each |
|---|
| 38 | 13.25 | Supply & fix LED lights, Nominal watt 35 Watt, Nominal lumen efficacy 90 lumen/Watt, high pressure die cast aluminium housing, 140-270V, 50 Hz, PF>0.95 LED street light luminaries to be mounted on octagonal hot-dip galvanized street light poles including 3 core 1 sqmm PVC insulated copper cable from control box to fitting complete all as spd and as directed by Engr-in-Charge Make: Philips)/ Wipro(Skyline) /Osram(Strada plus) complete all as spd and directed | | 6 | Each |
|---|
| 39 | 13.26 | Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 ( Part I and II) for protection of underground calbes of size 63 mm outer dia with all fittings. laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified (excavation and earth work shall be measured and paid separately) Make: Rex/Poly/Gemini | | 120 | RM |
|---|
| 40 | 13.27 | SOLAR WATER HEATER\nSupply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 2.5 sq mm ,2 core, 1100 Volts grade. | | 90 | RM |
|---|
| 41 | 13.28 | TELEPHONE CONDUIT\nM&L for RJ11 Telephone Jacks 1 module with pressed steel sunken box Equipped with modular Jack connector with 1/4 turn terminal for fast connection all as spd and directed. Make :- Legrand (Myrius) / Anchor (vision) / Havells (ORO) | | 10 | Each |
|---|
| 42 | 13.29 | M&L for TV socket outlet, 1 module complete all as spd and directed. Make :- Legrand (Myrius) / Anchor (vision) / Havells (ORO) | | 10 | Each |
|---|
| 43 | 13.3 | M&L for 10 Pair Telecom Junction box withKrone frame all as spd and directed | | 1 | Each |
|---|
| 44 | 13.31 | M&L for 0.5mm 2 Pair Telephone cable PVC insulated copper conductor all as spd and directed | | 120 | RM |
|---|
| 45 | 13.32 | M&L for TV cable PVC insulated copper conductor all as spd and directed | | 120 | RM |
|---|
| 46 | 13.33 | REFRIGERATION AND AIR CONDITION\nS&F automatic Voltage Stablizer of capacity 1 KVA single phasr, wall mount, copper wound, Air cooled with digital display, output voltage 220 V +/- 10%, Calibration Accuracy +/- 3% range 170-260 V all complete as specified and directed by Engineer-in-charge. Make :- V-Guard / VOLINA /AE | | 3 | Each |
|---|
| 47 | 13.34 | Supply and installation refrigerator elect driven single phase having approx storage capacity of 350 ltr, double door, frost free all complete as specified and directed by Engineer-in-charge.\nMake : Haier (HRF-3554BS-E)/SAMSUNG/GODREJ/LG | | 1 | Each |
|---|