BRR : 9174539
Tender Brief : Carriage Of Following Line Materials From Store Center Orai To Site With Work Including Measuring Weiging Loading Unloading At Both Ends And Proper Stacking At Safe Site.-2 St Pole 11 Mtr Long 3 Pcc Pole 8.5 Mtr Long 4 Acsr Rabbite Conductor 5 Dog Conductor 6 3X70 Sqmm 11Kv Xlpe Cable ( In Mtr ) 7 Weasel Conductor 8 T / F 400 Kva New 9 T / F 250Kva New 10 11 Kv T.P.M.O 11 11 Kv Fuse Set 12 3X120 Sqmm 11Kv Xlpe Cable ( In Mtr ) 13 11 Kv Metring Pilfer Of Ctr 10 / 5 Amp 14 11 Kv Double Merting Ct / Pt Unit Of 10 / 5 Amp. 15 11 Kv Vcb In-Coming ( 600 / 300 / 5A ) ... Read More
Tender Value
₹
54,50,000
Submission Date
12-10-2022
Participated Bidder List
3 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | |||||
| 2 | cnet-technologies | Bid Analytics | |||||
| 3 | cnet-technologies | Bid Analytics |
Work Detail
carriage of following line materials from store center orai to site with work including measuring weiging loading unloading at both ends and proper stacking at safe site.-2 st pole 11 mtr long 3 pcc pole 8.5 mtr long 4 acsr rabbite conductor 5 dog conductor 6 3x70 sqmm 11kv xlpe cable ( in mtr ) 7 weasel conductor 8 t / f 400 kva new 9 t / f 250kva new 10 11 kv t.p.m.o 11 11 kv fuse set 12 3x120 sqmm 11kv xlpe cable ( in mtr ) 13 11 kv metring pilfer of ctr 10 / 5 amp 14 11 kv double merting ct / pt unit of 10 / 5 amp. 15 11 kv vcb in-coming ( 600 / 300 / 5a ) 16 11 kv vcb out-going ( 200 / 100 / 5a ) 17 ( part-b ) supply of the following line item as per resspo drawing & dimension:- 18 stone pad ( 300x300x75mm ) 19 11 kv v type cross arm with holding clamp and nut and bolts 20 stay set complete with stay clamp and nut bolts 21 11kv pin insulator with g-i pin 22 11kv disc insulator 45 kn 23 11kv disc fitting for rabbit conductor 24 m.s. earthing complete ( 16mm dia, 3mtr long ) 25 f - bracket for 11kv line with nut & bolts 26 gi pipe 27 i / d & o / d cable jointing kit make rychen / denson 28 barbed wire ( no of pole x1.5kg ) 29 danger board with clamp of size ( 250x200x2mm thick ) 30 number plate ( 250x200x2mm thick ) 31 t off channel of size ( 125x65x1300mm ) with clamp 32 m.s. dropper channel ( 100x50x2028mm ) with clamp 33 m.s. top channel ( 125x65x2240mm ) with clamp 34 m.s. top channel ( 125x65x3200mm ) for four pole with clamp 35 m / s angle cross bracing of size ( 65x65x6x2700 mm long ) 36 red oxid paint 37 aluminium paint 38 other clamps 39 aluminium binding wire 40 off size nut, bolts and washer 41 gaurding angle 65x65x6 ( 1600mm long ) 42 g.i wire 7 swg 43 eye bolt 44 ( part-c ) erection of the following supports after making of pits as per resspo norms & filling of pits by concrete of ratio 1:4:8 ( cement brick balast & sand ) . fitting of all accessories as cross arm, top channel, bracing angle, pin insulator, disc insulator, danger board, number plate, barbed wire & clamps etc. plinthing of support above 300mm ground level by concrete of ratio 1:4:8 ( cement brick balast & sand ) will be done at the time of erection of pole. painting of st pole structure as per resspo norms also ( all type of nut, bolts & grouting material etc. will be provided by contractor ) . 45 single support of s.t pole 11 mtr long. 46 double pole structure on s.t. pole 11mtr long complete with bracing. 47 double pole structure on st pole 11 mtr long for sub station 48 four pole structure on st pole 11 mtr long complete with bracing. 49 single support of pcc pole 8.5 mtr long. 50 double pole structure on pcc pole 8.5 mtr long complete with bracing. 51 erection of stay set with stay wire, stay clamp & stay insulator including with grouting of stay set by concrete of ratio 1:4:8 as per resspo norms before back filling of the pits including binding, climbing, clamping, tightening and nozzeling of stay wire in all respect as per resspo norms. all clamps, nuts, bolts, stay insulator, cement. brick, ballast, sand etc would be provided by the contractor. 52 laying and sagging of 3 phase acsr rabbit conductorfrom double pole at 33 / 11 kv substation to double pole at tapping point of 11 kv feeder line including jumpering, hoisting fixing all type of insulators, binding jointing and its clamping etcin all respect. 53 earthing of each st and pcc poles of the line is to be done by inserting the ms earth rod ( 1800x16mm ) into soil by hammering and properly fastning with gi wire to each support & its accessories by nut & bolt. earthing rod must be 0.15 mtr. above from the plinth of the support. all type nut & bolt, earthing and gi wire will be suppliedby the contractor. 54 guarding of ht / lt / telephone line / road / river crossing etc. by providing g.s earth wire 7 / 16 swg / gi wire no. 8 / 10 and making net with difference of 1.00 mtr. completely including fixing of channel / angle etc. with proper locking at each support as per resspo norms. all type nut &bolts, would be provided by the contractor. 55 laying ofdouble circuit 11 kv 3x70 / 3x120 sq. mm xlpecable in normal soil in g.i. pipe by digging of trench 1050 mm deep, 750 mm wide including supply of required material as hdpe pipe, fine sand, 1st class bricks, stone slab. interaxial spacing between the two cable should be in between 0.25 m to 0.40m. 56 laying ofsingle circuit 11 kv 3x70 / 3x120 sq. mm xlpecable in normal soil in by digging of trench 1050 mm deep, 750 mm wide including supply of required material as , fine sand, 1st class bricks, stone slab. will be supplied by contractor. 57 fixing of 11 kv 3x70 / 3x120sqmm o / d and i / d sizes, makeraychem / denson. ( cable box will be supplied by the contractor ) . 58 fixing of 11 kv cable root marker 59 termination of 11 kv 3x120 sq mm size xlpe cable by filling 11 kv heat shrinkable type cable boxes including proper connection with 11 kv line, double metring ct / pt unit, 11 kv metring pilfer and 11 kv switch gears and double poles by providing suitable connectors.all the 11 kv cable boxes of different sizes makeraychem / denson. ( cable box will be supplied by the contractor ) . 60 painting of following support of existing 11 kv line with one coat of red oxide primer and two of alluminium white paint of isi mark and top danger portion of each support must be painted by providing two coat of red paint. 61 hoisting of 11 kv 3x120 sq. mm. xlpe cable on double pole with c class gi pipe of size 6 dia 3 m longincluding its jumpering complete with clamps, nuts and bolts. 62 construction of t / f plinght and fencing for 250 / 400 kva t / f of size 2x2x1.5 mtr. 63 installation of 11 kv metring pilfer in meter room and making h.t connections. 64 installation of double metring ct / pt unit. 65 clearing of the line route by cutting of tree branches during erection of line and also upto the time of energisation completely as per direction of site incharge. 66 cemical earthing of 11 / 0.4 kv 250 / 400 kva t / f
View Original Notice/Document
Result Documents
Tender Documents
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
Technical Evaluation In Progress
Technical bid evaluation is currently in progress. Awarded bidder details will be available after completion of technical scrutiny.
TechnicalBid
Similar Tenders Results