BRR : 2228037
Click Here To View Tendering Authority. Aoc City/State :  CTPP, RVUNL, Chhabra, Rajasthan
Tender Brief : Procurement Of Mcb, Mccb, Fuse Link, Sfu And Rccb For Ctpp, Chhabra Procurement Of Mcb, Mccb, Fuse Link, Sfu And Rccb For Ctpp, Chhabra , Mcb Suitable For Din Rail Type 2 Pole, 240Vac, Breaking Capacity= 10 Ka, B Curve, Ui = 660 V, Magnetic Release Setting = ( 5-10 ) In, Uimp = 4 Kv, Electrical / Mechanical Life > 30000 Operations, Ip20, Confirming To Is / Iec60898-1-2002 , 6A Mcb Suitable For Din Rail Type 2 Pole, 240Vac, Breaking Capacity= 10 Ka, B Curve, Ui = 660 V, Magnetic Release Setting = ( 5-10 ) In, Uimp = 4 Kv, Electrical / Mechanical Life > 30000 Operati... Read More
Tender Value
₹ 24,31,000
Contract Value
₹ 11,00,980.21
Saving / Difference
₹ 13,30,020 ▲
Submission Date
27-08-2021
Contract Date
23-04-2022
Completion Date
120 days
Participated Bidder List
7 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 53,421.7 L1
2 cnet-technologies Bid Analytics 1,60,628 L1
3 cnet-technologies Bid Analytics 55,356.38 L1
4 cnet-technologies Bid Analytics 1,64,371.64 L2
5 cnet-technologies Bid Analytics 3,82,470 L1
6 cnet-technologies Bid Analytics
7 cnet-technologies Bid Analytics 3,31,766.44 L1
Work Detail
procurement of mcb, mccb, fuse link, sfu and rccb for ctpp, chhabra procurement of mcb, mccb, fuse link, sfu and rccb for ctpp, chhabra , mcb suitable for din rail type 2 pole, 240vac, breaking capacity= 10 ka, b curve, ui = 660 v, magnetic release setting = ( 5-10 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 6a mcb suitable for din rail type 2 pole, 240vac, breaking capacity= 10 ka, b curve, ui = 660 v, magnetic release setting = ( 5-10 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , mcb suitable for din rail type 2 pole, 415vac, breaking capacity= 10 ka, b curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 63 a mcb suitable for din rail type 2 pole, 415vac, breaking capacity= 10 ka, b curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , mcb suitable for din rail type 3 pole, 415vac, breaking capacity= 10 ka, b curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 10000 operations, ip20, confirming to is / iec60898-1-2002 , 4a mcb suitable for din rail type 3 pole, 415vac, breaking capacity= 10 ka, b curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 10000 operations, ip20, confirming to is / iec60898-1-2002 , 6a mcb suitable for din rail type 3 pole, 415vac, breaking capacity= 10 ka, b curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 10000 operations, ip20, confirming to is / iec60898-1-2002 , 10a mcb suitable for din rail type 3 pole, 415vac, breaking capacity= 10 ka, b curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 10000 operations, ip20, confirming to is / iec60898-1-2002 , 16a mcb suitable for din rail type 3 pole, 415vac, breaking capacity= 10 ka, b curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 10000 operations, ip20, confirming to is / iec60898-1-2002 , 20a mcb suitable for din rail type 3 pole, 415vac, breaking capacity= 10 ka, b curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 10000 operations, ip20, confirming to is / iec60898-1-2002 , 32a mcb suitable for din rail type 3 pole, 415vac, breaking capacity= 10 ka, b curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 10000 operations, ip20, confirming to is / iec60898-1-2002 , 63a mcb suitable for din rail type 3 pole, 415vac, breaking capacity= 10 ka, b curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 10000 operations, ip20, confirming to is / iec60898-1-2002 , mcb suitable for din rail type 4 pole, 415vac, breaking capacity= 10 ka, b curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 6a mcb suitable for din rail type 4 pole, 415vac, breaking capacity= 10 ka, b curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 16a mcb suitable for din rail type 4 pole, 415vac, breaking capacity= 10 ka, b curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 32a mcb suitable for din rail type 4 pole, 415vac, breaking capacity= 10 ka, b curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 63a mcb suitable for din rail type 4 pole, 415vac, breaking capacity= 10 ka, b curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , mcb suitable for din rail type 1 pole, 240 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 5-10 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 0.5 a mcb suitable for din rail type 1 pole, 240 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 5-10 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 1a mcb suitable for din rail type 1 pole, 240 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 5-10 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 2a mcb suitable for din rail type 1 pole, 240 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 5-10 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 4a mcb suitable for din rail type 1 pole, 240 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 5-10 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 6a mcb suitable for din rail type 1 pole, 240 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 5-10 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 10a mcb suitable for din rail type 1 pole, 240 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 5-10 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 16a mcb suitable for din rail type 1 pole, 240 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 5-10 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 20a mcb suitable for din rail type 1 pole, 240 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 5-10 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 25a mcb suitable for din rail type 1 pole, 240 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 5-10 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 32a mcb suitable for din rail type 1 pole, 240 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 5-10 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , mcb suitable for din rail type 2 pole, 240 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 5-10 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 1a mcb suitable for din rail type 2 pole, 240 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 5-10 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 2a mcb suitable for din rail type 2 pole, 240 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 5-10 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 4a mcb suitable for din rail type 2 pole, 240 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 5-10 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 6a mcb suitable for din rail type 2 pole, 240 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 5-10 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 10a mcb suitable for din rail type 2 pole, 240 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 5-10 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 16a mcb suitable for din rail type 2 pole, 240 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 5-10 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 20a mcb suitable for din rail type 2 pole, 240 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 5-10 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 25a mcb suitable for din rail type 2 pole, 240 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 5-10 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 32a mcb suitable for din rail type 2 pole, 240 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 5-10 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , mcb suitable for din rail type2 pole, 415 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 6a mcb suitable for din rail type2 pole, 415 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 16a mcb suitable for din rail type2 pole, 415 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , mcb suitable for din rail type 2 pole, 415 vac, breaking capacity= 10 ka, c curve , 4a mcb suitable for din rail type 2 pole, 415 vac, breaking capacity= 10 ka, c curve , 6a mcb suitable for din rail type 2 pole, 415 vac, breaking capacity= 10 ka, c curve , 16a mcb suitable for din rail type 2 pole, 415 vac, breaking capacity= 10 ka, c curve , mcb suitable for din rail type 3 pole, 415 vac, breaking capacity= 10 ka, c curve , 3a mcb suitable for din rail type 3 pole, 415 vac, breaking capacity= 10 ka, c curve , 4a mcb suitable for din rail type 3 pole, 415 vac, breaking capacity= 10 ka, c curve , 6a mcb suitable for din rail type 3 pole, 415 vac, breaking capacity= 10 ka, c curve , 10amcb suitable for din rail type 3 pole, 415 vac, breaking capacity= 10 ka, c curve , 20amcb suitable for din rail type 3 pole, 415 vac, breaking capacity= 10 ka, c curve , 63amcb suitable for din rail type 3 pole, 415 vac, breaking capacity= 10 ka, c curve , mcb suitable for din rail type 4 pole, 415 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 3a mcb suitable for din rail type 4 pole, 415 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 4a mcb suitable for din rail type 4 pole, 415 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 10a mcb suitable for din rail type 4 pole, 415 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 16a mcb suitable for din rail type 4 pole, 415 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 32a mcb suitable for din rail type 4 pole, 415 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 50a mcb suitable for din rail type 4 pole, 415 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 63a mcb suitable for din rail type 4 pole, 415 vac, breaking capacity= 10 ka, c curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , mcb suitable for din rail type 4 pole, 415 vac, breaking capacity= 10 ka, d curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , 4a mcb suitable for din rail type 4 pole, 415 vac, breaking capacity= 10 ka, d curve, ui = 660 v, magnetic release setting = ( 3-5 ) in, uimp = 4 kv, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-1-2002 , mcb-dc suitable for din rail type 2 pole, 220 vdc, breaking capacity= 10 ka, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-2-2003 , 2a mcb-dc suitable for din rail type 2 pole, 220 vdc, breaking capacity= 10 ka, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-2-2003 , 4a mcb-dc suitable for din rail type 2 pole, 220 vdc, breaking capacity= 10 ka, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-2-2003 , 6a mcb-dc suitable for din rail type 2 pole, 220 vdc, breaking capacity= 10 ka, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-2-2003 , 10a mcb-dc suitable for din rail type 2 pole, 220 vdc, breaking capacity= 10 ka, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-2-2003 , 16a mcb-dc suitable for din rail type 2 pole, 220 vdc, breaking capacity= 10 ka, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-2-2003 , 25a mcb-dc suitable for din rail type 2 pole, 220 vdc, breaking capacity= 10 ka, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-2-2003 , mcb-dc suitable for din rail type 2 pole, 250 vdc, breaking capacity= 10 ka, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-2-2003 , 20a mcb-dc suitable for din rail type 2 pole, 250 vdc, breaking capacity= 10 ka, electrical / mechanical life > 30000 operations, ip20, confirming to is / iec60898-2-2003 , mcb , mcb rating- 2 pole, 1a, 230vac , mcb rating- 2 pole, 4a, 415vac , mcb rating- 2 pole, 6a, 415vac , mcb rating- 2 pole, 10a, 415vac , mcb rating- 2 pole, 16a, 415vac , mcb rating- 2 pole, 32a, 415vac , mcb rating- 2 pole, 50a, 415vac , fuse baseand fuse , 15-32a, closed type fusebase, 415v, essen , 6a fuse link, 415v, stagtag, hrc , 10a fuse link, 415v, stagtag, hrc , 16a fuse link, 415v, stagtag, hrc , 20a fuse link, 415v, stagtag, hrc , 35a fuse link, 415v, stagtag, hrc , mccb three pole, thermal magnetic trip, ue = 415 vac, 50 hz, icu = 25 ka, ui = 750 v, uimp = 8 kv, ics = 100%icu, adjustable overload and adjustable short circuit setting , 32a mccb three pole, thermal magnetic trip, ue = 415 vac, 50 hz, icu = 25 ka, ui = 750 v, uimp = 8 kv, ics = 100%icu, adjustable overload and adjustable short circuit setting , 40a mccb three pole, thermal magnetic trip, ue = 415 vac, 50 hz, icu = 25 ka, ui = 750 v, uimp = 8 kv, ics = 100%icu, adjustable overload and adjustable short circuit setting , 63a mccb three pole, thermal magnetic trip, ue = 415 vac, 50 hz, icu = 25 ka, ui = 750 v, uimp = 8 kv, ics = 100%icu, adjustable overload and adjustable short circuit setting , 100a mccb three pole, thermal magnetic trip, ue = 415 vac, 50 hz, icu = 25 ka, ui = 750 v, uimp = 8 kv, ics = 100%icu, adjustable overload and adjustable short circuit setting , 125a mccb three pole, thermal magnetic trip, ue = 415 vac, 50 hz, icu = 25 ka, ui = 750 v, uimp = 8 kv, ics = 100%icu, adjustable overload and adjustable short circuit setting , mccb four pole, thermal magnetic trip, ue = 415 vac, 50 hz, icu = 25 ka, ui = 750 v, uimp = 8 kv, ics = 100%icu, adjustable overload and adjustable short circuit setting , 100a , 125a , 200a , 250a , 320a , 350a , 400a , tp&n 415 vac-23a front handle operated switch disconnector fuse unit cubical type, without metallic enclosure, confirming to is: 13947 p-iii in existing panel ( w / o hbc fuses ) of following rating ( pwd bsr ( elect. ) -2013 code:e100400, group-1 ) , 63a rating ( e100402, group-1 ) , 100a rating ( e100403, group-1 ) , 125a rating ( e100403, group-1 ) , tp&n 415 v side handle operated double break switch unit in sheet steel enclosure, confirming to is: 13947 p-iii and is:4064 ( w / o hbc fuses ) including making connections with suitable lugs, testing etc. as required ( pwd bsr ( elect. ) -2013 code:e100300, group-1 ) , 63a rating ( e100301, group-1 ) , 100a rating ( e100302, group-1 ) , rccb suitable for din rail type 2 pole, un = 240 vac, 50 hz, ip40, residual operating current i?n = 30 ma, instantaneous tripping time at i?n < 40 ms, im = i?m > 500 a, inc = i?c = 6 ka, insulation voltage > 660 vdc, type a, power supply = top / bottom, terminal capacity min / max = 1.5 / 25 mm², with test button, confirming to is 12640-1:2008 , 40 a rccb suitable for din rail type 2 pole, un = 240 vac, 50 hz, ip40, residual operating current i?n = 30 ma, instantaneous tripping time at i?n < 40 ms, im = i?m > 500 a, inc = i?c = 6 ka, insulation voltage > 660 vdc, type a, power supply = top / bottom, terminal capacity min / max = 1.5 / 25 mm², with test button, confirming to is 12640-1:2008 , 63 a rccb suitable for din rail type 2 pole, un = 240 vac, 50 hz, ip40, residual operating current i?n = 30 ma, instantaneous tripping time at i?n < 40 ms, im = i?m > 500 a, inc = i?c = 6 ka, insulation voltage > 660 vdc, type a, power supply = top / bottom, terminal capacity min / max = 1.5 / 25 mm², with test button, confirming to is 12640-1:2008 , rccb suitable for din rail type 4 pole, un = 415 vac, 50 hz, ip40, residual operating current i?n = 30 ma, instantaneous tripping time at i?n < 40 ms, im = i?m > 500 a, inc = i?c= 6 ka, insulation voltage > 660 vdc, type a, power supply = top / bottom, terminal capacity min / max = 1.5 / 25 mm², with test button, confirming to is 12640-1:2008 , 32 a rccb suitable for din rail type 4 pole, un = 415 vac, 50 hz, ip40, residual operating current i?n = 30 ma, instantaneous tripping time at i?n < 40 ms, im = i?m > 500 a, inc = i?c= 6 ka, insulation voltage > 660 vdc, type a, power supply = top / bottom, terminal capacity min / max = 1.5 / 25 mm², with test button, confirming to is 12640-1:2008 , 63 a rccb suitable for din rail type 4 pole, un = 415 vac, 50 hz, ip40, residual operating current i?n = 30 ma, instantaneous tripping time at i?n < 40 ms, im = i?m > 500 a, inc = i?c= 6 ka, insulation voltage > 660 vdc, type a, power supply = top / bottom, terminal capacity min / max = 1.5 / 25 mm², with test button, confirming to is 12640-1:2008
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download 414236d3-3119-4d29-9995-f5c1eefb72ab
Download File Name File Description
Download 53f113c7-8b03-452a-88a9-9672d9c370fa Tender Documents
Download bid1109 Tender Documents
Download BOQ_420640 Tender Documents
Download Tendernotice_1 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000
Similar Tenders Results